Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ti6Al4V alloy" wg kryterium: Temat


Tytuł:
Vanadium oxide rich nanotubes on both phases of anodized Ti6Al4V alloy
Autorzy:
Kaczmarek, A.
Arkusz, K.
Krasicka-Cydzik, E.
Powiązania:
https://bibliotekanauki.pl/articles/284438.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
nanotubes
Ti6Al4V alloy
implants
Opis:
Ti6Al4V, if used as an implant material is becoming replaced by other titanium based medical alloys due to the toxicity of vanadium. Anodic modification carried out to obtain nanoporous structures on this two-phase material leads to the formation of oxides only over а phase, vanadium rich ß phase oxide being etched [1,2] due to the high solubility of V-oxides. However, vanadium oxides having excellent conductive [3,4] and catalytic [5] properties, with ability to bind proteins [6] and similar to phosphates in the metabolic affinity to insulin mimics [7]. Such properties are prospective for using anodised nanotubular layer of the Ti6Al4V as a biosensor platform. Anodizing the Ti6Al4V alloy in phosphoric acid with fluoride ions gives nanotubes presented in Fig.1a, whereas using 99.0% ethylene glycol with 0.6% fluorides leads to formation of uniform 50nm diameter nanotubes on both phases Fig. 1b. To next experiments for thermal modification and electrochemical examination the most appropriate surface was obtained during anodization in 99% ethylene glycol with 0.6% of NH4F in 20V during 20min. Thermal modification was carried in 600PC in three atmospheres (air, argon and nitrogen), only modification in nitrogen does not affect on the nanotubes morphology, in other cases shape and nanotubular character of oxide layer changes to nonregular oxide structures. Corrosion potential, cyclic voltametry and EIS studies carried in PBS solution for each of thermally modified oxide surface confirmed unique electric properties of obtained layers. Obtained novel coating with nanotubular TiO2, Al2O3, and VOX and their conductive, biological and catalytic properties may be a bioactive and cell growth stimulating layer, a platform for high sensitive sensors, or nanodimensional electrode material.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 155
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of thermochemical treatment methods on pitting corrosion resistance of Ti6Al4V alloy
Autorzy:
Czerniak-Reczulska, M.
Burnat, B.
Grabarczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/285526.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V alloy
corrosion
thermochemical treatment
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 71
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deposition of various gradient multilayer coatings on Ti-6Al-4V alloy using MW CVD methods for orthopaedic implants
Autorzy:
Kyzioł, K.
Oczkowska, J.
Klich, M.
Kaczmarek, Ł.
Kyzioł, A.
Powiązania:
https://bibliotekanauki.pl/articles/283831.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V alloy
coatings
orthopaedic implants
Źródło:
Engineering of Biomaterials; 2017, 20, no. 143 spec. iss.; 26
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Plasma oxidized Ti6Al4V and Ti6Al7Nb alloys for biomedical applications
Autorzy:
Pązik, B.
Grabarczyk, J.
Batory, D.
Kaczorowski, W.
Burnat, B.
Czerniak-Reczulska, M.
Makówka, M.
Niedzielski, P.
Powiązania:
https://bibliotekanauki.pl/articles/285698.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Ti6Al4V alloy
Ti-6Al-7Nb alloy
biomaterials
Źródło:
Engineering of Biomaterials; 2016, 19, 138; 68
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji powierzchni na odporność korozyjną stopu Ti-6Al-7Nb
Influence of surface modification on corrosion resistance of Ti-6Al-7Nb alloy
Autorzy:
Basiaga, M.
Szewczenko, J.
Paszenda, Z.
Marciniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/285355.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stop Ti-6Al-4V
korozja
biomateriały
Ti-6Al-4V alloy
corrosion
biomaterials
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 140-144
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warstwy azotowane jarzeniowo na stopie tytanu Ti6Al4V dla zastosowań w kardiologii
Glow discharge nitrided layers on Ti6Al4V alloy intended for cardiovascular applications
Autorzy:
Borowski, T.
Sowiński, A.
Ossowski, M.
Czarnowska, E.
Wierzchoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/284718.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stop tytanu Ti-6Al-4V
kardiologia
implanty
Ti6Al4V alloy
cardiovascular applications
implants
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 49-51
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność korozyjna utlenianego anodowo stopu Ti6Al4V ELI po długotrwałej ekspozycji w płynie Ringera
Corrosion resistance of anodized Ti6Al4V ELI alloy after long-term exposure to Ringer’ solution
Autorzy:
Szewczenko, J.
Marciniak, J.
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/284734.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
odporność korozyjna
stop Ti-6Al-4V
biomateriały
corrosion resistance
Ti6Al4V alloy
biomaterials
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 21-25
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie elektrochemicznej spektroskopii impedancyjnej do oceny stopu Ti-6Al-4V ELI stosowanego w ortopedii
Electrochemical impedance spectroscopy study of Ti-6Al-4V ELI alloy used in orthopeadic
Autorzy:
Pochrząst, M.
Marciniak, J.
Walke, W.
Kaczmarek, M.
Szewczenko, J.
Loska, S.
Powiązania:
https://bibliotekanauki.pl/articles/285377.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
spektroskopia impedacyjna
ortopedia
stop Ti-6Al-4V
impedance spectroscopy
orthopaedics
Ti-6Al-4V alloy
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 149-153
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of Aluminum During the Process of Ti-6Al-4V Alloy, Smelting in a Vacuum Induction Furnace
Eliminacja aluminium w procesie wytopu stopu Ti-6Al-4V w indukcyjnym piecu próżniowym
Autorzy:
Siwiec, G.
Powiązania:
https://bibliotekanauki.pl/articles/355814.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Vacuum Induction Melting
Ti-6Al-4V alloy
evaporation
mass transfer coefficient
Opis:
In the paper, results of the study on kinetics of aluminum evaporation from a liquid Ti-6Al-4V alloy during its smelting in a vacuum induction furnace are presented. The experiments were performed with the use of a VIM 20-50 furnace (manufactured by SECO-WARWICK) at 1973 K and 5-1000 Pa. Based on the values of changes in aluminum concentration in a liquid alloy, overall mass transfer coefficients were estimated. Within the analysed pressure range, the coefficient values changed from 0.97·10⊃ -5 ms⊃ -1 to 1.93·10⊃ -5 ms⊃ -1 for 1000 Pa and 5 Pa, respectively.
W pracy przedstawiono wyniki badan kinetyki procesu odparowania aluminium z ciekłego stopu Ti-6Al-4V w trakcie jego wytopu w próżniowy piecu indukcyjnym. Badania realizowano w piecu VIM 20-50 produkcji firmy SECO-WARWICK w temperaturze 1973 K i zakresie ciśnień 5-1000 Pa. Na podstawie uzyskanych wyników zmian stężenia aluminium w ciekłym stopie oszacowano wartości ogólnego współczynnika transportu masy. W analizowanym zakresie ciśnień wartość tego współczynnika zmieniała się odpowiednio od 0,97·10⊃ -5 ms⊃ -1 dla ciśnienia 1000 Pa do 1.93·10⊃ -5 ms⊃ -1 dla ciśnienia 5 Pa.
Źródło:
Archives of Metallurgy and Materials; 2012, 57, 4; 951-956
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Ti6Al4V P/M Properties Under Thermomechanical Compression Tests
Autorzy:
Sleboda, T.
Fourie, J.
Powiązania:
https://bibliotekanauki.pl/articles/379823.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti6Al4V alloy
thermomechanical condition
compression test
stop Ti6Al4V
warunki termomechaniczne
próba ściskania
Opis:
Since titanium powder metallurgy poses opportunities for the manufacture of a range of components, there now exists the need to establish its performance characteristics under industrial conditions that these components need to operate under. In line with this, there is a need to analysing amongst others the mechanical properties of Ti6Al4V P/M [1, 5] under various thermomechanical conditions and compression tests. The main objective of the research is to study and compare the properties after forging of high quality Ti6Al4V powder metallurgy alloy with that of titanium ingot. Both samples has been manufactured under the same thermo mechanical conditions. P/M alloy will be prepared from the mixture of elemental powders, and will have the chemical composition of that of ingot Ti6Al4V alloy as per ASTM 1580-1 standard. Powder mixtures will be fully densified by hot compaction under precisely controlled conditions using the Thermal Technology Inc. press at AGH University of Science and Technology in Poland. Various physical tests will be conducted including mechanical property tests and microstructural analysis. Additionally simulations will be performed using simulation software, GForm ™ , using parameters used on actual forgings. Results will be compared to physical tests performed earlier.
Źródło:
Archives of Foundry Engineering; 2013, 13, 3 spec.; 149-152
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the analysis of chip shaping after finishing turning of Ti6Al4V titanium alloy under dry, wet and MQL conditions
Autorzy:
Leksycki, Kamil
Feldshtein, Eugene
Powiązania:
https://bibliotekanauki.pl/articles/94178.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
chip shape
cooling/lubricating cutting environment
MQL
finish turning
Ti6Al4V alloy
Opis:
The shape and type of chip give general information about the cutting process. This paper presents the results of testing the shape and type of chips of Ti6Al4V titanium alloy after it finishes turning. The process was carried out under dry, wet and MQL (Minimum Quantity Lubrication) conditions at variable cutting speeds and feed rates and a constant depth of cutting. For planning the tests, the PSI (Parameter Space Investigation) method was used, which allows the experiment to be carried out while minimizing the number of experience points. It was found that the cutting speed and feed affect the type and shape of the chip, and clear differences were observed between dry and wet cooling conditions, and MQL conditions. During turning, the intensity of the cutting speed and feed influence on the chip compression ratio was changed. It was similar for dry and wet cooling conditions but smaller for MQL conditions. The purpose of this research is to analyze the chip shaping when Ti6Al4V titanium alloy finishes turning under dry, wet and MQL cooling conditions.
Źródło:
Archives of Mechanical Technology and Materials; 2019, 39; 36-40
2450-9469
Pojawia się w:
Archives of Mechanical Technology and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural, Mechanical and Tribological Properties of Spark Plasma Sintered Ti6Al4V Alloy
Autorzy:
Mróz, A.
Grabiec, D.
Wielowiejska-Giertuga, A.
Wiśniewski, T.
Gierzyńska-Dolna, M.
Matyła, A.
Powiązania:
https://bibliotekanauki.pl/articles/353018.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti6Al4V alloy
spark plasma sintering
mechanical properties
friction and wear properties
Opis:
The influence of spark plasma sintering parameters on the structural, mechanical and tribological characteristics of the Ti6Al4V alloy, which is used as implant material in biomedical engineering, was investigated. The experimental data confirm that full density and attractive mechanical properties can be obtained using the spark plasma sintering method. Tribological tests, performed in dry conditions, allowed the authors to indicate the most suitable sintering parameters. The material characterized by the highest wear resistance was selected for further tribological testing in articulation with UHMWPE in simulated body fluids. Although the weight of the polymeric material articulating against the sintered Ti6Al4V was slightly higher compared to the UHMWPE articulating against the reference material (Ti6Al4V rod), the friction coefficient was lower.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 665-670
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The kinetics of aluminium evaporation from the Ti-6Al-4V alloy
Kinetyka parowania aluminium ze stopu Ti-6Al-4V
Autorzy:
Siwiec, G.
Powiązania:
https://bibliotekanauki.pl/articles/350864.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti-6Al-4V alloy
evaporation
kinetics
vacuum induction melting
stop Ti6Al4V
parowanie
kinetyka
próżniowe topienie indukcyjne
Opis:
In the paper, results of a kinetic analysis of aluminium evaporation from the Ti-6Al-4V alloy are presented. The analysis was performed based on the findings obtained during the alloy smelting in the vacuum induction furnace at 5 Pa to 1000 Pa and at 1973 K, 1998 K and 2023 K.
W prezentowanej pracy przedstawiono wyniki analizy kinetycznej procesu parowania aluminium ze stopu Ti-6A1-4V. Przeprowadzono ją w oparciu o wyniki badań uzyskane w trakcie topienia stopu w indukcyjnym piecu próżniowym w zakresie ciśnień 5-1000 Pa w temperaturach 1973 K, 1998 K i 2023 K.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 4; 1155-1160
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of Ti-6Al-4V Alloy Surface by EPD-PEO Process in ZrSiO4 Suspension
Modyfikacja powierzchni stopu Ti-6Al-4V metodą PEO-EPDw zawiesinie ZrSiO4
Autorzy:
Krząkała, A.
Młyński, J.
Dercz, G.
Michalska, J.
Maciej, A.
Niużyła, Ł.
Simka, W.
Powiązania:
https://bibliotekanauki.pl/articles/356201.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti-6Al-4V alloy
suspension
anodic oxidation
zirconium silicate
stop Ti6Al4V
zawiesina
utlenianie anodowe
krzemian cyrkonu
Opis:
Investigations on the surface modification of the Ti-6Al-4V alloy by plasma electrolytic oxidation are reported here. The oxidation process was carried out in a solution containing a zirconium silicate (ZrSiO4) suspension and sodium hydroxide (NaOH). Anodising was realised at voltages in a range from 100 V to 250 V. It was found that the morphology of the sample surface did not change during the oxidation of the alloy at 100 V. Application of voltages higher than 100 V led to the incorporation of zirconium silicate into the formed oxide layer and to significant changes of the surface morphology.
W pracy przedstawiono wyniki badań nad modyfikacją powierzchni stopu Ti-6A1-4V metodą plazmowego utleniania elek- trochemicznego. Proces ten prowadzono w roztworze zawierającym zawiesinę krzemianu cyrkonu (ZrSiO4 oraz wodorotlenek sodu (NaOH). Anodowanie prowadzono w zakresie napięcia od 100 do 250 V. Stwierdzono, że zastosowanie napięcia 100 V nie powoduje zmian w morfologii powierzchni stopu. Natomiast zastosowanie napięcia wyższego od 100 V powoduje wbudowanie krzemianu cyrkonu w tworzącą się warstewką tlenową oraz znaczne zmiany w morfologii powierzchni stopu Ti-6A1-4V.
Źródło:
Archives of Metallurgy and Materials; 2014, 59, 1; 199-204
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury spiekania na gęstość, mikrostrukturę i właściwości wytrzymałościowe stopu Ti6Al4V wytwarzanego metodą iskrowego spiekania plazmowego (SPS)
The influence of sintering temperature on the density, microstructure and strength properties of the Ti6Al4V alloy produced using the spark plasma sintering method (SPS)
Autorzy:
Garbiec, D.
Heyduk, F.
Wiśniewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/212193.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Obróbki Plastycznej
Tematy:
iskrowe spiekanie plazmowe
ciepło Joule'a
stop Ti6Al4V
spark plasma sintering
Joule heat
Ti6Al4V alloy
Opis:
W artykule omówiono metodę iskrowego spiekania plazmowego. Przedstawiono schemat urządzenia oraz wyjaśniono mechanizm spiekania impulsami prądu stałego. Opracowano proces spiekania proszku stopu Ti6Al4V. Przedstawiono wyniki pomiarów gęstości, mikrostrukturę spieków i wyniki badań wytrzymałości na rozciąganie w zależności od temperatury spiekania. Wykazano, Se wraz ze wzrostem temperatury spiekania wzrasta gęstość oraz wytrzymałość na rozciąganie.
The spark plasma sintering method is discussed in the article. A diagram of the device is presented, and the mechanisms of sintering using direct current impulses is explained. The sintering process for Ti6Al4V alloy powder has been developed. The results of density measurements, sinter microstructure, and the results of tensile strength tests as a dependency on sintering temperature are presented. It was shown, that as sintering temperature increases, density and tensile strength also increase.
Źródło:
Obróbka Plastyczna Metali; 2012, 23, 4; 265-275
0867-2628
Pojawia się w:
Obróbka Plastyczna Metali
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies