Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Surge" wg kryterium: Temat


Tytuł:
Nonlinear Load and RLC Pulse Shaping Surge Generator Models in Simulation Environment
Autorzy:
Edirisinghe, M.
Powiązania:
https://bibliotekanauki.pl/articles/412021.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Nonlinear load
surge generator
surge protection
loading effect
Opis:
The present study was performed in order to understand how a nonlinear load affects the characteristics of the RLC pulse shaping surge generator waveforms under simulation studies. The obtained results were compared when analytical equations were used as source models for both 1.2/50 s voltage & 8/20 s current impulses. Three circuit models; Capacitor Bank generator, Combination waveform generator and Schaffner generator were evaluated under nonlinear loads varied from 10Ω to 106 Ω for voltage impulses and for current impulses it was from 10-4 Ω to 1 Ω. As it can perceive from the analysis, delay time, rise time and FWHM remain unchanged throughout the tested impedance range when used model equations as generator sources. It was found that for voltage impulses, these values were 4.95 μs, 1.20 μs and 81.8 μs respectively. For current impulses, these values were 16.2 μs, 8.02 μs and 20.7 μs respectively. However results obtained for generator circuit models shows that delay time, rise time and FWHM deviated from above values up to maximum of 35.15 %, 106.67 % & 115.16 % respectively for voltage impulses. For current impulses these deviations were up to maximum of 79.63 %, 48.75 % & 39.61 % respectively. The deviations were due to influence caused by the nonlinear load to the generator circuit parameters and effective internal impedance.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 17, 3; 334-347
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Studies on Degradation of Varistors Subjected to Operation in Surge Arresters and Surge Arrester Counters
Autorzy:
Papliński, P.
Wańkowicz, J.
Śmietanka, H.
Ranachowski, P.
Ranachowski, Z.
Kudela, S. jr.
Aleksiejuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/351611.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surge arrester
surge arrester counter
MO varistor
microstructure of ceramics
ceramic material degradation
Opis:
The paper presents results of investigation of microstructure and micro-hardness for material of ZnO varistors applied to 110 kV surge arrester and surge arrester counter. The research combined two pairs of varistors, each consisted of one varistor subjected before to operation, while the other one was brand new unit and constituted a reference. All varistors were made of the same material by the reputable manufacture. The tests revealed a different degree of the material degradation for varistors subjected before to operation. This also refers to different degradation mechanism observed for the material of these varistors, if typical effects of degradation of aged ZnO varistors were considered as a reference. Physical state of spinel in the microstructure had a significant impact on the material degradation, however a considerable loosening of the microstructure associated with bismuth oxide was observed too. It was surprising, since the precipitates of the bismuth oxide phase most often showed very good binding to the ZnO matrix and high resistance to associated electrical, thermal and mechanical effects. The degradation effects in the ZnO matrix proved to be limited only.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 1; 367-374
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical surge modeling based on the pressure oscillations in the stable operation range of the compressor
Autorzy:
Jaeschke, A.
Liśkiewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/175279.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
radial compressors
surge
Greitzer model
Opis:
Prevention of surge phenomenon is a very active field of research in last decades. The Greitzer model is the most widely applied mathematical model describing the surge phenomenon. Two parameters that characterize the given compressing system: the Helmholtz oscillator frequency and the so-called B parameter have to be given as the input to Greitzer model. Although those parameters are easy to determine for simplified compressor models, they are extremely hard to predict in case of real industrial compressors. Moreover, in most cases it is impossible to analyse compressor unstable work, which makes this prediction even more speculative. Therefore the method that determines the parameters basing on the compressor stable operation is indispensable. In paper the regularly perturbed Greitzer model based method of predicting the behaviour of a compressor in the unstable operation basing on signals from its stable operation is proposed and discussed.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 133; 91-108
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wewnętrzna ochrona odgromowa obiektów zabytkowych
Internal lightning protection in the monumental buildings
Autorzy:
Dłużniewski, A.
John, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/373125.pdf
Data publikacji:
2011
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
ochrona przeciwprzepięciowa
strefowa ochrona przeciwprzepięciowa
udar elektryczny
electric surge
lightning protection zone
surge protectors
Opis:
W artykule omówiono zasady ochrony urządzeń elektrycznych i elektronicznych znajdujących się w obiektach zabytkowych przed przepięciami. Ochrona przeciwprzepięciowa polega na zastosowaniu strefowej koncepcji ochrony urządzeń i systemów. Opisano podstawowe zasady ekranowania i prowadzenia instalacji elektrycznej i transmisji sygnałów w celu uniknięcia sprzężeń pomiędzy instalacjami znajdującymi się w zabytkowym obiekcie. Podano przykłady ochrony urządzeń elektronicznych znajdujących się w starych dworkach ze względu na ich znaczenie kulturalne. Pokazano również przykłady zabezpieczenia przed przepięciami systemów i urządzeń znajdujących się w zabytkowym obiekcie kolejowym na przykładzie nastawni dyspozytorskiej, które przystosowano do instalowania nowoczesnych urządzeń elektronicznych.
The article discusses the principle of protection of electrical and electronic equipment located in monumental buildings before the surge. Surge Protection is the partition using the concept of security devices and systems. Describes the basic principles of screening and conduct electrical signals and to avoid linkage between installations located in the monumental building. Protection are examples of electronic devices located in the old manor monumental because of their cultural significance. Showing examples of surge protection systems and equipment located in a historic building on the example of railway control room dispatcher, which is adapted to the installation of modern electronic devices.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2011, 1; 151-162
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania z zakresu ochrony odgromowej wykonane na Politechnice Wrocławskiej
Lightning protection research carried out at Wroclaw university of technology
Autorzy:
Chrzan, K.L.
Powiązania:
https://bibliotekanauki.pl/articles/267395.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
zwody aktywne
ogranicznik przepięć
gapped surge arresters
metal oxide surge arresters
early streamer emission terminals
Opis:
Wymieniono pierwsze instalacje piorunochronów w Rzeczypospolitej i na Dolnym Śląsku. Opisano badania skuteczności zwodów pionowych na makiecie obserwatorium meteorologicznego oraz skuteczności zwodów aktywnych ESE. Przedstawiono najważniejsze osiągnięcia w zakresie badania odporności zabrudzeniowej odgromników zaworowych i ograniczników beziskiernikowych. Streszczono pomiary wytrzymałości udarowej zabrudzonych izolatorów.
The first installation of Franklin rods in Kingdom of Poland and in Silesia Province were listed. The investigation of Franklin rods efficacy and inefficacy of early streamer emission terminals were shown. The most important achievements in the research of pollution resistance of gapped and gapless surge arresters was reported. The measurements of lightning flashover voltage of polluted insulators were described.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2008, 24; 29-34
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antisurge Systems-State of the Art
Autorzy:
Grapow, Filip
Powiązania:
https://bibliotekanauki.pl/articles/1178312.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Surge
antisurge system
compressors
flow instabilities
Opis:
Industry today can’t exist without compressors. Very often they are most important part of installation and profits of enterprise depends on them. Every failure of this machine results in stoppage of production and therefore enormous loses. One of the biggest threat to stable operation of compressors is flow instability called surge. It occurs in conditions of low mass flow rate and appears as an oscillations of pressure and mass flow and it’s capable of destroying machine in just few seconds. To prevent from this dangerous phenomenon antisurge systems are used. In this paper division of antisurge systems and literature study of current knowledge and technologies are presented. Examples of different types of antisurge systems and future trends are discussed. This paper summarize today’s state of knowledge about methods of prevention from surge.
Źródło:
World Scientific News; 2017, 81, 2; 53-68
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona przed przepięciami instalacji elektroenergetycznych niskiego napięcia
Overvoltage protection for low-voltage power installations
Autorzy:
Szadkowki, Marek
Juraszek, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1861056.pdf
Data publikacji:
2020
Wydawca:
Centrum Usług i Projektów Janusz Juraszek
Tematy:
sieć niskiego napięcia
przepięcie
ogranicznik przepięć
ochrona przepięciowa
low voltage network
surge
surge protective device
lightning protection
Źródło:
Era Energii; 2020, 1; 4-9
2658-0195
Pojawia się w:
Era Energii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post−surge geometry and thermal structure of Hørbyebreen, central Spitsbergen
Autorzy:
Małecki, Jakub
Faucherre, Samuel
Strzelecki, Mateusz C.
Powiązania:
https://bibliotekanauki.pl/articles/2051391.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
Svalbard
glacier surge
glacier geometry changes
Źródło:
Polish Polar Research; 2013, 3; 305-321
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compressor modeling using Greitzer model validated by pressure oscillations
Autorzy:
Grapow, F.
Liśkiewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/175456.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
centrifugal compressor
surge
greitzer model
compressor modeling
Opis:
Nowadays compressors are used in almost every industry. Compressor failure can suspend production of the whole system so the importance of preventing from failures is obvious and essential. One of the most dangerous flow instabilities which is capable of destroying machine in few seconds is surge, which occurs in conditions of low mass flow rate. Greitzer model, apart from its long history, is still most common mathematical model describing surge. It is widely used to predict the surge onset and pressure oscillations during it. However, it is based on parameters that are not directly related to real machine and their choice is not always obvious. Therefore, the calculations may be inaccurate which results in wrong surge prediction. The other approach to Greitzer model is presented in this paper, which in some cases can assure that the process of compressor modeling is more accurate. The applicability of Greitzer surge model for real machines has been analyzed. Method of implementation is based on experimental pressure signal gathered during unstable work of compressor. Presented method is based on experimental compressor characteristic and outlet pressure signal from unstable work of compressor. From that data it is possible to determinate the value of Greitzer model’s parameters for selected operational point. Thanks to this method this model could be applied for reliable antisurge protection.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 133; 69-89
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic and Electrical Test of Medium Voltage Surge Arresters
Autorzy:
Lisowska-Lis, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/114064.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
surge arresters
medium voltage
thermography
discharge current
cooling
Opis:
The paper presents the results of a thermal test (conducted with thermographic camera, coupled with an electrical test) of medium voltage metal–oxide surge arresters. Surge arresters (for Uc=18 kV) were tested for the leakage current and surface temperature: for 5 minutes under state 50 Hz alternating voltage 18 kV. The surface temperature of the MOAs correlates with an increase in leakage current. The result shows that the 0.6 mA AC leakage current in the medium voltage metal–oxide surge arrester (18 kV) is above the stable operating point, and the loss of electrical power is higher than the effective heat dissipation in the arrester. After 5 minutes of high voltage impact U = 18 kV, the surface temperature of the surge arrester was (4.32±0.55) K higher than the initial temperature. The IR camera can be used to detect the faults of ZnO metal–oxide surge arresters that lead to an increase in surface temperature.
Źródło:
Measurement Automation Monitoring; 2019, 65, 2; 60-63
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
One phase active filter with energy storage for active power surge compensation in feed line
Autorzy:
Sowa, K.
Baszyński, M.
Piróg, S.
Powiązania:
https://bibliotekanauki.pl/articles/141248.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power quality
active power filter
power surge compensation
Opis:
The paper presents a concept of an active filter with energy storage. This solution can be used for the compensation of momentary one phase high power loads with discontinued power consumption (e.g. spot welding machines). Apart from the typical filtering capabilities, the system’s task is also the continuity of the input power from the feeder line and limiting its fluctuation. The proposed by the author’s solution can produce measurable economic benefits by reducing the rated power necessary to energize periodically operating loads and improving the indicators of electrical energy quality. The developed method of active power surges compensation enables a flexible approach to requirements concerning the rated power of the point to which the periodically operating loads with high peak current value are connected. The tests were conducted on a simulation model specially developed in Matlab & Simulink environment, proving high effectiveness of the presented solution.
Źródło:
Archives of Electrical Engineering; 2016, 65, 2; 221-234
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer modelling of lighting power controller operation disturbed by 1.2/50 μs voltage lightning stroke
Autorzy:
Typańska, D.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/376687.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
surge impulse
computer simulations
lighting installation
power regulator
Opis:
The article presents a computer simulation of a lighting installation disturbed by lightning surge. Modelled impulse voltage generator 1.2/50 μs, system with coupling/ decoupling system and a power semiconductor regulator used in light engineering have been described. The aim of the work was to investigate the influence of the surge impulse on the current flowing through the installation.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 93; 159-168
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of metal oxide surge arresters as elements of overvoltage protection systems
Modelowanie ograniczników przepięć z tlenków metali jako elementów systemów ochrony przepięciowej
Autorzy:
Furgał, J.
Dau, S. K.
Powiązania:
https://bibliotekanauki.pl/articles/320307.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
ograniczniki przepięć
symulacje komputerowe
surge arresters
mathematical modelling
Opis:
Metal oxide surge arresters are used for protection of high and low voltage electric devices against overvoltages. Mathematical models of surge arresters should properly represent current-voltage dependencies of varistors during influence overvoltages. From among numerous models created so for two versions of a selected model were used for computer simulations of current-voltage dependences of surge arresters. Parameters of elements of the selected model can be calculated by use of data published in the catalogues. Current-voltage dependencies of the surge arrester designed for electric power systems of 110 kV for different current stroke were modelled. The results of computer simulations were compared with the experimental data.
Ograniczniki przepięć są powszechnie stosowane do ochrony przepięciowej urządzeń elektrycznych wysokiego i niskiego napięcia. Modele matematyczne ograniczników powinny właściwie odzwierciedlać charakterystyki napięciowo-prądowe warystorów podczas oddziaływania przepięć. Spośród wielu modeli opracowanych dotychczas do symulacji komputerowych zależności napięciowo-prądowych wybrano jeden model ograniczników. Parametry elementów modelu wyznaczono przy wykorzystaniu danych katalogowych. Modelowano zależności napięciowo-prądowe dla różnych udarów prądowych ogranicznika przepięć stosowanego w układach elektroenergetycznych 110 kV. Obliczenia porównano z wynikami badań.
Źródło:
Elektrotechnika i Elektronika; 2008, 27, 1; 14-19
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Degradation Processes in Shield-Centring Elements of Surge Arresters
Autorzy:
Papliński, P.
Śmietanka, H.
Ranachowski, P.
Ranachowski, Zbigniew
Wieczorek, K.
Kudela, S. jr.
Powiązania:
https://bibliotekanauki.pl/articles/2203744.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surge arrester
TSE glass textolite
discharge current
EDS method
Opis:
This paper presents the results of testing samples of shield-centering elements from medium-voltage surge arresters. The elements were made of TSE glass textolite. The elements have been dismantled from different operated surge arresters, which were subjected to discharge currents (short-circuit currents) of different intensity and duration. The discharge currents led to degradation of the tested elements with various degrees of advancement. The degradation was investigated using microscopic methods and energy-dispersive X-ray spectroscopy (EDS). Changes in the content of elements of the surface of textolite materials - as the degradation progresses - were documented. It was found that high discharge current flows resulted in melting of the organic binder, epoxy resin, especially its surface layer. Partial charring and even burning of the resin was noticeable. Furthermore, it was found that with increasing degradation on the surface of the TSE laminate, the carbon and oxygen content, which are part of the organic resin, decreases. Simultaneously the amount of silicon, calcium and aluminium, which are present in the glass fibres, increases. The charring effect of the resin and the formation of conductive paths result in a decrease in the performance of surge arresters and their subsequent failure.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 1; 237--242
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operation of two-shaft gas turbine in the range of open anti-surge valve
Autorzy:
Dzida, M.
Frost, J.
Powiązania:
https://bibliotekanauki.pl/articles/260558.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
gas turbine
anti-surge valve
laboratory stand
experimental studies
Opis:
This paper presents experimental tests of full-scale two-shaft gas turbine in the range of open anti-surge valve (ASV). The tests were carried out in a laboratory gas- turbine test stand belonging to Department of Automation and Power Engineering , Faculty of Ocean Engineering and Ship Technology , Gdańsk University of Technology. The tests covered the start-up and low load operation of the turbine set in the range of open anti-surge valve.
Źródło:
Polish Maritime Research; 2017, 4; 85-92
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona odgromowa obiektów kolejowych
Surge arrester protection of railway objects
Autorzy:
Białoń, A.
Dłużniewski, A.
John, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/253208.pdf
Data publikacji:
2010
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
transport kolejowy
ochrona odgromowa
rail transport
surge arrester protection
Opis:
Ostatnio obserwuje się zwiększenia nakładów finansowych ponoszonych na modernizację wielu zabytkowych obiektów, zlokalizowanych wzdłuż linii kolejowych. Proces ten ma miejsce w trakcie postępujących modernizacji linii kolejowych.
Źródło:
TTS Technika Transportu Szynowego; 2010, 10; 37-40
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wentyl Gilesa-Mościckiego
Giles-Moscicki’s valve
Autorzy:
Chrzan, Krystian Leonard
Powiązania:
https://bibliotekanauki.pl/articles/1857445.pdf
Data publikacji:
2021
Wydawca:
Wydawnictwo Druk-Art
Tematy:
przepięcie
ogranicznik przepięć
iskiernik
overvoltage
surge arrester
spark gap
Opis:
W artykule przedstawiono prace prof. Ignacego Mościckiego (prezydenta Polski w latach 1926–1939), których wynikiem było zbudowanie nowego typu ogranicznika przepięć. W literaturze technicznej jest on jednak znany tylko jako wentyl Gilesa od nazwiska dyrektora fabryki kondensatorów we Fryburgu. Po prawie 100 latach konstrukcję wentylu Gilesa-Mościckiego wykorzystano ponownie w ograniczniku przepięć MC 50-B.
The article presents the works of prof. Ignacy Mościcki (president of Poland in the years 1926–1939), which resulted in the construction of a new type of surge arrester. In technical literature, however, it is only known as the Giles valve, after the director of the capacitors factory in Fribourg. After almost 100 years, the Giles-Mościcki valve structure was reused in the surge protective device MC 50-B.
Źródło:
Napędy i Sterowanie; 2021, 23, 4; 69-71
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remote sensing of eskers from Vormsi and Väinameri vicinity, northwestern Estonia
Autorzy:
Aber, J. S.
Kalm, V.
Powiązania:
https://bibliotekanauki.pl/articles/2059322.pdf
Data publikacji:
2001
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
Estonia
Palivere
landsat
esker
subglacial meltwater
ice lobe surge
Opis:
We have utilised techniques of remote sensing in combination with ground observations in order to investigate eskers of the Vormsi and Väinameri region of northwestern Estonia. Landsat Thematic Mapper (TM) images were the basis for recognition and regional interpretation of esker systems, and kite aerial photography was employed for detailed, low-height views of selected eskers. A special Landsat TM composite was developed to enhance the display of shallow sea floor features. On this basis, we have extended known, land-based eskers across the sea floor, and we have identified additional probable eskers marked by shallow shoals and tiny islands. The known and suspected eskers of Vormsi and surroundings demonstrate a regular pattern in their distribution, which we suggest represents a subglacial drainage network that was anastomosing in character. The esker network is located along the central pathway of the Väinameri ice lobe, and the overall direction of drainage was toward the Palivere glacial limit. We interpret eskers of the Vormsi-Väinameri vicinity as evidence for substantial meltwater discharge beneath the Väinameri ice lobe, which terminated in a proglacial lake.
Źródło:
Geological Quarterly; 2001, 45, 4; 365-372
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of inlet distortion effects on axial compressor performance based on streamline curvature method
Autorzy:
Abbasi, S.
Pirnia, A.
Taghavi-Zenouz, R.
Powiązania:
https://bibliotekanauki.pl/articles/281973.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
axial compressor
performance map
inlet distortion
surge margin
streamline curvature
Opis:
In this paper, the effects of inlet flow distortion on performance maps and details of the flow field are investigated using the Streamline Curvature Method. The results are presented for both design and off-design conditions and compared with experimental data, which shows good agreement. The effects of inlet flow distortion are investigated by inlet total pressure variation in three different cases in the way that the average total pressure remains constant and equal to the design value. The results show that a relative increase in the total pressure at tip causes an increase in the pressure ratio and efficiency as well as a better performance in the choking region. Alternatively, a relative increase in the total pressure in hub causes opposite behavior and a better performance at the surging region.
Źródło:
Journal of Theoretical and Applied Mechanics; 2018, 56, 4; 1005-1015
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kable powrotne w łączu SWEPOL LINK
Proposals for protection of return cables on SWEPOL LINK
Autorzy:
Szczepański, T.
Powiązania:
https://bibliotekanauki.pl/articles/266659.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
kabel powrotny
ogranicznik przepięć
elektroda
return cable
surge arrester
electrode
Opis:
Kabel powrotny w łączu Szwecja-Polska pojawił się jako alternatywa wymuszona przez ekologów, spowodowana brakiem akceptacji społecznej. Dlatego w wykonanym rozwiązaniu zastąpiono wodę i ziemię dwoma kablami powrotnymi, chociaż z punktu widzenia technicznego wprowadzone rozwiązanie daje niższą sprawność. Ostatnie, jedenaste uszkodzenie kabla powrotnego wystąpiło w 2012 roku. W ośmiu wcześniejszych przypadkach przyczyną awarii były uszkodzenia elektryczne kabla w morzu w odległości kilkunastu kilometrów od polskiego brzegu, spowodowane zakłóceniami w północnej części polskiego systemu elektroenergetycznego. W tej sytuacji dla łącza Szwecja-Polska zaproponowano przeanalizowanie i zrealizowanie jednego lub dwóch niżej przedstawionych rozwiązań, które mogą istotnie ograniczyć skutki i koszty z tytułu uszkodzeń kabli powrotnych: a) montaż dodatkowych ograniczników przepięć, b) powrót do elektrod – całkowity brak kabli powrotnych, c) elektrody „niepełne” pracujące z jednym kablem powrotnym, d) praca łącza jedynie z uziemieniami własnymi na stacjach przekształtnikowych. Reasumując należy stwierdzić, że: - stosunkowo tanim sposobem dalszego uodpornienia kabli powrotnych na uszkodzenia elektryczne jest zabudowa ograniczników przepięć w szafce przy kontenerze na polskim brzegu, - z proponowanych środków zaradczych rozsądnym wydaje się zastosowanie wyżej wymienionych propozycji a) i d) jednocześnie, gdyż są to proste rozwiązania, nie wymagające dużych nakładów finansowych ani jakichkolwiek zgód, a mogą szybko zapewnić oczekiwany rezultat.
The return cable on SwePol Link has been introduced as an alternative enforced by environmentalists due to lack of social acceptance for other solutions. This is why in the proposed solution water and earth have been replaced by two return cables, although from the technical point of view such solution is less effective. The last, eleventh fault of return cable took place on 15 October 2012. In eight earlier cases the faults were caused by electrical failures in the cable in the sea and were located between ten and twenty kilometers from the Polish shore and triggered by disturbances in the northern part of the Polish power grid. In this situation it has been suggested to analyze and introduce one or two solutions shown below which may significantly limit the effects and lower the costs caused by return cable faults: a) assembly of additional surge arresters, b) return to electrodes – lack of return cables, c) “partial” electrodes working with one return cable, d) operation of the link only with earthings on converter stations. To sum up it needs to be said that: - a relatively cheap way of protecting return cables against electrical failures is installing surge arresters in the cabinet located next to the cable container on the Polish shore, - from the suggested preventive measures it seems reasonable to introduce the above mentioned solutions a) and d) simultaneously, as both of them are simple solutions which require neither considerable financial expenditures nor authorizations and may fast show expected results.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 35; 39-44
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stable or not stable? Recognizing surge based on the pressure signal
Autorzy:
Garcia, D.
Liśkiewicz, G.
Powiązania:
https://bibliotekanauki.pl/articles/175253.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
singular spectrum analysis
nonlinear dynamics
statistical pattern recognition
compressor
surge
Opis:
The surge protection may be worth millions of dollars. This is typical price of a centrifugal compressor repair combined with additional cost of nonfunctionality of an industry employing it. This threat is normally secured by application of an antisurge systems. Typically they are activated at predefined working conditions when compressor mass flow rate approaches region affected by the surge. As a result those systems are vastly limiting its operational range usually by a desirable region where compressor attains large pressure ratio. Therefore, a modern antisurge systems are aiming at diminishing this tradeoff by reacting to the real pressure signal gathered at high frequency. This paper presents one of those methods employing singular spectrum analysis. This algorithm has not been widely used for this application, while it was shown herein that it may bring clear distinction between stable and nonstable working condition, even at presurge conditions. Hence in further perspective it may bring anti-surge protection quality, that was not met with another methods.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 133; 55-68
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody diagnostyczne ograniczników przepięć
Diagnostics methods of metal oxide surge arresters
Autorzy:
Chrzan, K.
Powiązania:
https://bibliotekanauki.pl/articles/157473.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metody diagnostyczne
ograniczniki przepięć
diagnostic methods
metal oxide surge arresters
Opis:
Opisano najważniejsze metody diagnostyczne ograniczników przepięć: pomiaru temperatury sondami TINYTALK lub SAW, kompensacji, pomiaru prądu całkowitego, harmonicznych prądu i składowej rezystancyjnej prądu.
The most important diagnostic methods of metal oxide surge arresters were described: temperature measurement using TINYTALK sensors or SAW sensors (Surface Acoustic Wave), compensation method, total current measurement, current harmonics measurement and resistive current measurement.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 4, 4; 14-16
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposals for Protection of Return Cables on SwePol Link
Propozycje ochrony kabli powrotnych w łączu Szwecja – Polska
Autorzy:
Szczepański, T.
Powiązania:
https://bibliotekanauki.pl/articles/397506.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
return cable
surge arrester
electrode
kabel powrotny
ogranicznik przepięć
elektroda
Opis:
The return cable on the SwePol Link has been introduced as an alternative forced by environmentalists due to lack of social acceptance of other solutions. This is why in the proposed solution water and earth have been replaced by two return cables, although from a technical point of view such a solution is less effective. The last, eleventh fault of the return cable took place on 15 October 2012. In eight earlier cases the faults were caused by electrical failures in the cable in the sea and were located between ten and twenty kilometers from the Polish shore and triggered by disturbances in the northern part of the Polish power grid. In this situation it has been suggested to analyze and introduce one or two solutions shown below which may significantly limit the effects and lower the costs caused by return cable faults: a) assembly of additional surge arresters b) return to electrodes – lack of return cables c) ”partial” electrodes working with one return cable d) operation of the link only with earthings on converter stations. To sum up it needs to be stated that: • a relatively cheap way of protecting return cables against electrical failures is installing surge arresters in the cabinet located next to the cable container on the Polish shore • from the suggested preventive measures it seems reasonable to introduce the above mentioned solutions a) and d) simultaneously, as both of them are simple solutions which require neither considerable financial expenditure nor authorizations and may quickly show the expected results.
Streszczenie Kabel powrotny w łączu Szwecja – Polska pojawił się jako alternatywa wymuszona przez ekologów. Dlatego w wykonanym rozwiązaniu zastąpiono wodę i ziemię dwoma kablami powrotnymi, chociaż z punktu widzenia technicznego wprowadzone rozwiązanie daje niższą sprawność. Ostatnio do jedenastego uszkodzenia kabla powrotnego doszło 15 października 2012 roku. W ośmiu wcześniejszych przypadkach przyczynami awarii były uszkodzenia elektryczne kabla w morzu, w odległości kilkunastu kilometrów od polskiego brzegu, spowodowane zakłóceniami w północnej części polskiego systemu elektroenergetycznego.
Źródło:
Acta Energetica; 2013, 1; 147-156
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie przepięć atmosferycznych jako źródeł zakłóceń w układach zasileniach odbiorów nieatrakcyjnych
Modeling atmospheric power surges as sources of discruptions in non-traction power system
Autorzy:
Wróbel, Z.
Ziemba, R.
Powiązania:
https://bibliotekanauki.pl/articles/249746.pdf
Data publikacji:
2008
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
odbiór nietrakcyjny
przepięcie atmosferyczne
non-traction power system
power surge
Opis:
Podczas występowania bezpośredniego udaru piorunowego w układach zasilających odbiory potrzeb nietrakcyjnych zagrożenie uszkodzenia urządzeń może występować niemal przy każdym wyładowaniu, nawet dość odległym. Skutkiem tego na przepięcia o dużych amplitudach narażone są elementy układów zasilania linii potrzeb nietrakcyjnych i połączone z nimi urządzenia sterowania ruchem kolejowym (srk). Możliwe jest występowanie w układach zasilających zakłóceń o wielkościach porównywalnych z sygnałami użytecznymi wywoływanych wyładowaniami atmosferycznymi lub będących wynikiem zadziałania zdalnych impulsów elektromagnetycznych.
Źródło:
TTS Technika Transportu Szynowego; 2008, 12; 41-44
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure and Degree of Degradation of ZnO Varistors in Surge Arresters Due to Operation
Autorzy:
Papliński, P.
Wańkowicz, J.
Ranachowski, P.
Ranachowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/356415.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
surge arrester
MO varistor
microstructure of ceramics
ceramic material degradation
Opis:
The paper presents the test results for the microstructure of ZnO varistors comprising high voltage gapless surge arresters. The tests were performed on varistors produced in different periods and by various manufacturers. The research was inspired by different characteristics of changes in values of current flowing through surge arresters as a function of changes in values of system voltage in a 220 kV substation, and the temperature in a multi-year cycle. Furthermore, the effects of varistor microstructure degradation following a failure of an unsealed surge arrester were investigated. The results provided the grounds for assessment of ZnO varistor microstructure parameters in terms of their durability and resistance to degradation processes.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 3; 1267-1273
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies