Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "DC/AC converter" wg kryterium: Temat


Tytuł:
Design and construction of a polygon-connected autotransformer-based 36-pulse AC-DC converter for power quality improvement in retrofit applications
Autorzy:
Abdollahi, R.
Powiązania:
https://bibliotekanauki.pl/articles/202052.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC-DC converter
polygon autotransformer
power quality
36-pulse rectifier
direct torque controlled induction motor drive (DTCIMD)
konwerter AC-DC
jakość energii
prostownik impulsowy
DTCIMD
Opis:
This paper presents the design and analysis of a polygon connected autotransformer based 36-phase AC-DC converter which supplies direct torque controlled induction motor drives (DTCIMD’s) in order to have better power quality conditions at the point of common coupling. The proposed converter output voltage is accomplished via two paralleled eighteen-pulse AC-DC converters each of them consisting of nine-phase diode bridge rectifier. An autotransformer is designed to supply the rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. The proposed structure improves power quality criteria at ac mains and makes them consistent with the IEEE-519 standard requirements for varying loads. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for the proposed topology at variable loads. A laboratory prototype of the proposed Polygon-Connected autotransformer-based 36-pulse AC-DC converter is developed and test results are presented to validate the developed design procedure and the simulation models of this AC-DC converter under varying loads.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 353-362
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of delta/polygon-connected transformer-based 36-pulse ac-dc converter for power quality improvement
Autorzy:
Abdollahi, R.
Powiązania:
https://bibliotekanauki.pl/articles/140490.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
jakość energii
prostownik 36-pulsowy
bezpośredni moment obrotowy silnika indukcyjnego sterowanego napędem
AC-DC converter
delta/polygon transformer
power quality
direct torque controlled induction motor drive (DTCIMD)
Opis:
Design of a delta/polygon-connected autotransformer based 36-pulse ac-dc converter is presented in this paper. The 36-pulse topology is obtained via two paralleled eighteen-pulse ac-dc converters each of them consisting of a nine-phase (nine-leg) diode bridge rectifier. For independent operation of paralleled diode-bridge rectifiers, two interphase transformers (IPT) is designed and implemented. A transformer is designed to supply the rectifier. The design procedure of magnetics is in a way such that makes it suitable for retrofit applications where a six-pulse diode bridge rectifier is being utilized. The proposed structure has been implemented and simulated using Matlab/Simulink software under different load conditions. Simulation results confirmed the significant improvement of the power quality indices (consistent with the IEEE-519 standard requirements) at the point of common coupling. Furthermore, near unity power factor is obtained for a wide range of DTCIMD operation. A comparison is made between 6-pulse and proposed converters from view point of power quality indices. Results show that input current total harmonic distortion (THD) is less than 4% for the proposed topology at variable loads.
Źródło:
Archives of Electrical Engineering; 2012, 61, 2; 277-292
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetworniki termoelektryczne AC/DC jako wzorce napięcia przemiennego
AC/DC thermal transfer converters as AC voltage standards
Autorzy:
Barański, A.
Ratajczak, J.
Zawadzki, P.
Powiązania:
https://bibliotekanauki.pl/articles/153578.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetworniki termoelektryczne AC/DC
napięcie przemienne
wartość skuteczna
AC/DC thermal transfer converter
AC voltage
true RMS
Opis:
Pomiary napięcia przemiennego w Głównym Urzędzie Miar są odnoszone do wzorców odtwarzanych przy napięciu stałym, wg zasady komparacji niejednoczesnej. W charakterze wzorca odniesienia przy napięciu przemiennym stosowane są zestawy przetworników termoelektrycznych. Struktura wzorca, dzięki różnym konfiguracjom, umożliwia pokrycie potrzeb wzorcowania tej wielkości do 1200 V i częstotliwości do 1 MHz. Omówiono istotę i źródła błędu komparacji, oraz sposób jego kompensacji. Schemat interkomparacji wzorca umożliwia odniesienie całej dziedziny do jednego przetwornika bazowego 1 VAC.
AC voltage measurements at the Central Office of Measures are being referenced to the standards restored at the DC voltage according to the principle of anti-coincidental comparison. As an AC voltage reference standard sets of thermoelectric converters are being used. Thanks to different configurations,the structure of the standard,enables covering the calibration needs of this quantity up to 1200 V at the frequency of up to 1 MHz. The nature and sources of comparison error were discussed as well as the way of its compensation. The schematic diagram of intercomparison enables referencing the whole field to one 1 VAC base converter.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 38-41
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The DC-side active filter with dual-buck full-bridge inverter for wind generators
Autorzy:
Chen, X-Q.
Zhao, S-W.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/141358.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-pulse ac-dc converter
auto-transformer
harmonic suppression
DC-side active filter
dual-buck full-bridge inverter
Opis:
This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method and dual-buck full-bridge inverter having not the “shoot-through” problem in conventional bridge-type inverters, and therefore this system with the character low harmonic distortion and high reliability. The proposed dc-side active filter is realized by using dual-buck full bridge converter, which directly injects compensation current at dc-side of two six-pulse diode bridges rectifiers. Compared with the conventional three-phase active power filter at ac-side, the system with the dc-side active filter draws nearly sinusoidal current by shaping the diode bridges output current to be triangular without using the instantaneous reactive power compensation technology, only using simple hysteretic current control, even though under load variation and unbalanced voltage disturbances, and while an acceptable linear approximation to the accurate waveform of injection current is recommended. The performance of the system was simulated using MATLAB/Simulink, and the possibility of the dc-side active filter eliminating current harmonics was confirmed in steady and transient states. The simulation results indicate, the system has a total harmonic distortion of current reduced closely to 1%, and a high power factor on the wind generator side.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 263--277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Predictive and look-up table control methods of a three-level AC-DC converter under distorted grid voltage
Autorzy:
Falkowski, P.
Kulikowski, K.
Grodzki, R.
Powiązania:
https://bibliotekanauki.pl/articles/201956.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-level AC/DC converter
direct power control
finite contol set model predictive control
lookup table method
AC/DC
trzypoziomowy konwerter AC/DC
Opis:
Power electronic three-level AC-DC converters connecting a utility grid with DC supplies are widely used in renewable energy sources. For such distributed systems, the quality of energy is very important. Hence, control algorithms of an AC-DC converter have to provide not only a sinusoidal shape of grid current, but also stable operation during transient states in the grid, e.g. voltage dips or voltage unbalance. This paper deals with the problem of robustness of AC-DC control methods under disturbed grid voltage. Three modern predictive control algorithms are presented and investigated under grid voltage distortions. Experimental results from a laboratory test setup illustrating properties of the described methods are shown.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 609-618
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid-tied converter operated under unbalanced and distorted grid voltage conditions
Autorzy:
Gałecki, A.
Michalczuk, M.
Kaszewski, A.
Ufnalski, B.
Grzesiak, L. M.
Powiązania:
https://bibliotekanauki.pl/articles/200867.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
grid tied converter
AC/DC converter
current controller
resonant controller
particle swarm optimization (PSO)
Opis:
The paper presents a three-phase grid-tied converter operated under unbalanced and distorted grid voltage conditions, using a multi-oscillatory current controller to provide high quality phase currents. The aim of this study is to introduce a systematic design of the current control loop. A distinctive feature of the proposed method is that the designer needs to define the required response and the disturbance characteristic, rather than usually unintuitive coefficients of controllers. Most common approach to tuning a state-feedback controller use linear-quadratic regulator (LQR) technique or pole-placement method. The tuning process for those methods usually comes down to guessing several parameters. For more complex systems including multi-oscillatory terms, control system tuning is unintuitive and cannot be effectively done by trial and error method. This paper proposes particle swarm optimization to find the optimal weights in a cost function for the LQR procedure. Complete settings for optimization procedure and numerical model are presented. Our goal here is to demonstrate an original design workflow. The proposed method has been verified in experimental study at a 10 kW laboratory setup.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 2; 389-398
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Trójfazowy przekształtnik mocy AC/DC
Three-Phase Ac/Dc Power Converter
Autorzy:
Gospodarczyk, A.
Majcher, A.
Mrozek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1368481.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
trójfazowy przekształtnik AC/DC
układ korekcji współczynnika mocy (PFC)
three-phase AC/DC converter
Power Factor Correction (PFC)
Opis:
The article presents the design of a three-phase AC/DC power converter. The requirements and solutions used for this type of systems are described. The presented converter is made as full bridge and a halfcontrolled bridge circuits. The comparison of the results for the two solutions indicates higher utility of the full bridge circuit. The converter has a simple and a cost-effective design, complies with the normative requirements for harmonic emissions, the possibility of bidirectional flow of energy. The versatility of this converter allows for its application in three-phase energy conversion of permanent magnet generator to DC energy and its further processing to the public electricity AC network.
W artykule przedstawiono konstrukcję trójfazowego przekształtnika mocy AC/DC. Opisano wymagania oraz stosowane rozwiązania dla tego typu układów. Przedstawiony przekształtnik wykonano w topologii pełnego mostka oraz mostka pół-sterowanego. Porównanie wyników badań obu rozwiązań wskazuje na wyższą użyteczność układu mostkowego. Przekształtnik cechuje się prostą i tanią konstrukcją, zgodnością z wymaganiami normatywnymi emisji harmonicznych, możliwością dwukierunkowego przepływu energii. Uniwersalność opracowania pozwala na jego aplikację do konwersji trójfazowej energii prądnic z magnesami trwałymi na energię prądu stałego w celu jej dalszego przetwarzania na energię AC publicznej sieci zasilającej.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 2, 99; 219-225
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Toward extending the frequency of the AC–DC voltage transfer at Silesian University of Technology up to 10 MHz
Autorzy:
Grzenik, M.
Kampik, M.
Powiązania:
https://bibliotekanauki.pl/articles/114066.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
AC–DC transfer
AC voltage standard
thermal converter
Opis:
The paper presents steps taken to extend the frequency range of the thermal AC-DC voltage transfer maintained at SUT up to 10 MHz. The properties of the measurement setup are described after replacing the Fluke 5700A calibrator used as AC voltage source up to 1 MHz with the Fluke 6071A RF signal generator. Next the results of the consistency checking of the AC–DC transfer difference measurements performed with the new measurement setup is presented. The results of verification of the correctness of the calculated and measured AC–DC transfer differences of the two calculable thermal AC voltage standards are presented in 1–10 MHz frequency range. The inconsistency of the measured AC–DC transfer difference is below 55 μV/V at 10 MHz, when comparing PMJTCs with SJTC and below 25 μV/V when comparing PMJTCs among themselves. The AC–DC transfer difference of the SUT calculable AC voltage standard was calculated from the modified mathematical model for frequencies up to 10 MHz. Direct comparison of the 3 V calculable AC voltage standard with the 5 V one confirmed correctness of the results obtained from the mathematical model.
Źródło:
Measurement Automation Monitoring; 2016, 62, 2; 46-48
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczenie niezależnej od częstotliwości składowej różnicy transferowej termicznych wzorców napięcia przemiennego
Determination of frequency-independent AC-DC transfer difference of thermal AC voltage standards
Autorzy:
Grzenik, M.
Kampik, M.
Powiązania:
https://bibliotekanauki.pl/articles/269165.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wzorce
wzorzec napięcia przemiennego
transfer AC-DC
termiczny przetwornik wartości skutecznej
wartość skuteczna
standards
AC voltage standard
AC-DC transfer
thermal voltage converter
Opis:
W pracy przedstawiono wyniki badań pierwotnych i roboczych wzorców, utrzymywanych w Laboratorium Wzorców AC-DC Instytutu Metrologii, Elektroniki i Automatyki Politechniki Śląskiej. Celem badań było wyznaczenie wartości niezależnego od częstotliwości składnika różnicy transferowej tych wzorców. Z przeprowadzonych badań wynika, iż wartość tego parametru jest dla wszystkich zbadanych wzorców równa zeru ze standardową niepewnością 0,5 µV/V. Dla porównania zależna od częstotliwości składowa różnicy transferowej wzorca pierwotnego o UN = 3 V przy częstotliwości 1 MHz jest równa około 14,2 µV/V ze standardową niepewnością 1,5 µV/V.
The paper presents results of investigations of thermal AC voltage standards developed and maintained in the Laboratory of AC-DC Standards at the Institute of Measurement Science, Electronics and Control of Silesian University of Technology, Gliwice, Poland. The goal of these investigations was determination of the frequency-independent component of the AC-DC transfer difference of the four thermal AC voltage standards. Two of them were primary standards using selected single-junction thermal converters (SJTCs) and the other two were working standards using planar multijunction thermal converters (PMJTCs). The frequency-independent component of the AC-DC transfer difference was determined with a few methods including the measurement with the fast-reversed source (FRDC) maintained at the Swiss national metrology institute METAS and calibration in the German national metrology institute PTB. The analysis of obtained results, performed using the minimum squares method shows, that the frequency-independent component of the AC-DC transfer difference of the all four thermal AC voltage standards is equal to zero with standard uncertainty 0.5 µV/V.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 75-78
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Control strategies for the grid side converter in a wind generation system based on a fuzzy approach
Autorzy:
Harrabi, N.
Kharrat, M.
Aitouche, A.
Souissi, M.
Powiązania:
https://bibliotekanauki.pl/articles/331304.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wind energy conversion system
DC link
DC-AC converter
Mamdani fuzzy controller
T–S fuzzy controller
elektrownia wiatrowa
przekształtnik DC-AC
regulator rozmyty typu Mamdaniego
Opis:
Two techniques for the control of a grid side converter in a wind energy conversion system. The system is composed of a fixed pitch angle wind turbine followed by a permanent magnet synchronous generator and power electronic converters AC-DC-AC. The main interest is in how to control the inverter in order to ensure the stability of the DC link voltage. Two control methods based on the fuzzy approach are applied and compared. First, a direct Mamdani fuzzy logic controller is presented. Then, a T–S fuzzy controller is elaborated based on a T–S fuzzy model. The Lyapunov theorem and H-infinity performance are exploited for stability analysis. Besides, the feedback controller gains are determined using linear matrix inequality tools. Simulation results are derived in order to prove the robustness of the proposed control algorithms and to compare their performances.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2018, 28, 2; 323-333
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on Control Strategies for a Single-Phase Photovoltaic Inverter Using PSCAD/EMTDC Software
Autorzy:
Henz, Cristiano Luiz
Gasparin, Fabiano Perin
Powiązania:
https://bibliotekanauki.pl/articles/1956010.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
DC/DC converter
DC/AC converter
photovoltaic module
pulse width modulation
solar energy
Opis:
In the last decades, electric power produced through photovoltaic conversion has been increasing because of the need to reduce fossil fuel burning. Recently, photovoltaic systems have become more competitive and their role in the renewable energies market share is steadily gaining in importance. Improvements in the power electronics employed in the DC/AC conversion are topics of interest in the quest for more efficient and eventually reduced-cost inverters. The goal of this paper is to perform an investigation of control strategies and propose a topology for a single-phase DC/AC converter for photovoltaic arrays using the simulation software Power System Computer Aided Design/Electromagnetic Transient Design and Control (PSCAD/EMTDC). The circuit proposed in this paper employs an isolating transformer to a grid-connected photovoltaic inverter. The control strategy proposed uses the instantaneous reactive power theory (p–q theory) and phase-locked loop (PLL). The p-q theory uses two virtual axes in the Park Transformation, which provide to the control system a good dynamic response, accuracy, and decoupling between the control and power system. Computer simulations using the electromagnetic transient software PSCAD show the efficiency of the proposed strategy for a single-phase inverter. The control strategy and topology are quite simple and easy to implement in the future using a Digital Signal Processor (DSP). The results provide insights into new power electronics solutions, which can improve the efficiency and efficacy of the current available in DC/AC converters for photovoltaic systems.
Źródło:
Power Electronics and Drives; 2021, 6, 41; 75-99
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie przekształtnikiem AC/DC w interfejsie energoelektronicznym dla mikroinstalacji prosumenckiej
Control of AC/DC converter for power electronic interface for prosumer micro-grids
Autorzy:
Jarek, G.
Jeleń, M.
Michalak, J.
Zygmanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1201915.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
prosumencka mikroinfrastruktura elektroenergetyczna (PME)
przekształtnik AC/DC
interfejs energoelektroniczny
przekształtnik 4-gałęziowy
mikro- i nanoinstalacje
prosumer electrical micro-infrastructure
AC/DC converter
power electronic interface
4 leg converter
micronano grids
Opis:
The paper presents power electronic interface destined for prosumers micro-/nano-grids. The presented interface allows integrating different renewable energy sources and energy storages in to the single DC link circuit which is the internal part of the analyzed interface. Presented system enables the operation in two modes. The first is the on-grid mode when the interface is connected to the power grid and the second is the off-grid mode when the interface and prosumer micro-grid are disconnected from the grid and operate in the island mode. One of the major part of the analyzed power electronic interface is the AC/DC converter which is referred here as a grid converter. The paper deals with the operational issues of the interface with focusing on the control of all converters which form the interface. The special attention is paid on control method of the AC/DC converter, which has to be changeable due to the operation of the interface in different modes. Three AC/DC converter control strategies are described here, among which two represent on-grid modes and one is for off-grid operation. The first strategy from the on-grid modes is for the interface with the energy storage but the second is for the interface without this storage. In the third strategy the AC/DC converter operates in islanding mode. The changeable structure of the AC/DC converter controller is illustrated with simulation examples for all three modes.
Artykuł dotyczy interfejsu energoelektronicznego, przeznaczonego dla mikroinstalacji prosumenckich. Rozwiązanie to pozwala na integrację po stronie szyny DC różnych źródeł energii odnawialnej i zasobnika energii oraz umożliwia pracę w trybie on-grid (współpraca z siecią elektroenergetyczną) lub w trybie off-grid (praca na sieć wydzieloną). Z punktu widzenia współpracy z siecią i zasilania odbiorników napięcia przemiennego najważniejszą rolę pełni przekształtnik AC/DC. W artykule omówiono możliwości i działanie interfejsu energoelektronicznego, a następnie skupiono się na zagadnieniach sterowania poszczególnymi przekształtnikami składowymi. Szczególną uwagę poświęcono zagadnieniu sterowania przekształtnika AC/DC, w którym występuje zmiana strategii sterowania w zależności od warunków pracy. Omówiono poszczególne strategie sterowania przekształtnika AC/DC, przeznaczone odpowiednio dla: współpracy z siecią przy występowaniu zasobnika, współpracy z siecią przy braku zasobnika oraz dla pracy na sieć wydzieloną. Przedstawiono algorytm sterowania, a działanie przekształtnika AC/DC zilustrowano wynikami badań symulacyjnych.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2016, 2, 110; 139-145
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stosowane metody zasilania i izolacji galwanicznej sterowników bramkowych tranzystorów mocy w mostkowych stopniach końcowych wzmacniaczy klas D i falowników
Applied methods of power supply and galvanic isolation of gate drivers of power transistors in bridging end stages of Class D amplifiers and inverters
Autorzy:
Jasielski, J.
Kuta, S.
Powiązania:
https://bibliotekanauki.pl/articles/93168.pdf
Data publikacji:
2018
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
układ Bootstrap
pompa ładunkowa
sterownik bramkowy
technika izolacji sygnałów cyfrowych
wzmacniacz klasy D
PWM
PSCPWM
sterownik DC-AC
bootstrap power supply
charge pump
gate driver
galvanic isolation of the control signals
class D amplifier
DC-DC converter
Opis:
W pracy dokonano przeglądu i oceny różnych technik zasilania i izolacji galwanicznej sterowników bramkowych tranzystorów mocy w stopniach końcowych wzmacniaczy klasy D oraz różnego rodzaju konwerterów DC-AC lub DC-DC. Opisano i porównano techniki wytwarzania pływających napięć zasilających sterowniki bramkowe tranzystorów górnej części mostka w konfiguracji typu bootstrap oraz w konfiguracji typu samo-doładowującej się pompy ładunkowej, a także przedstawiono techniki izolacji galwanicznej sygnałów cyfrowych: optyczną i pojemnościową, które mogą być wykorzystane do sterowania tranzystorów w górnej części mostka. Przedstawiony w pracy oryginalny mostkowy wzmacniacza klasy BD z dwubrzegową modulacją PWM z przesuwaniem fazy sygnału modulowanego PSC PWM i zerowym sygnałem wspólnym na wyjściu pokazuje, że w układach budowanych w oparciu o wielopoziomowe metody modulacji PWM, prawie wszystkie sterowniki tranzystorów stopnia końcowego wymagają pływających napięć zasilających i izolacji galwanicznej. W takich układach najpewniejszą i niezawodną metodą zasilania i izolacji galwanicznej sterowników bramkowych tranzystorów mocy w stopniach końcowych są układy samodoładowujących się pomp ładunkowych z izolacją galwaniczną sygnałów cyfrowych ze sprzężeniem pojemnościowym. Poprawność działania stopnia końcowego tego wzmacniacza, wraz ze wszystkimi układami sterującymi, zweryfikowano za pomocą symulacji komputerowych w programie PSpice.
Various methods used for a floating high-side gate drive power supply and galvanic isolation of the Class-D amplifiers and different DC-AC or DC-DC converters have been reviewed and evaluated in the paper. On the basis of the literature, the bootstrap floating supply and self-boost charge pump topology for a gate drive high-side power supply, as well as control signal isolated systems with optically-isolated signals or with capacitive signal isolation have been described and compared. New topologies of the Class-BD amplifiers with Common-Mode (CM) free outputs using PSC PWM - Phase Shifted Carrier Pulse Width presented in the paper, shows that almost all gate drivers of the output stage transistors require floating power supply and galvanic isolation of the control signals. In the case of such circuits with multi-level PWM output, the most reliable and robust method for the floating gate drive power supply and galvanic isolation is self-boost charge pump topology with capacitive control signal isolation. Correct operation of the output stage of the proposed Class-BD amplifiers as well as the PWM modulator and self-boost charge pump topologies with capacitive control signal isolation have been verified using intensive Pspice simulation.
Źródło:
Science, Technology and Innovation; 2018, 2, 1; 31-41
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precision Calculations of the Characteristic Impedance of Complex Coaxial Waveguides Used in Wideband Thermal Converters of AC Voltage and Current
Autorzy:
Kubiczek, Krzysztof
Kampik, Marian
Powiązania:
https://bibliotekanauki.pl/articles/2124756.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC voltage standard
current shunt
characteristic impedance
multilayer cylindrical conductor
FEM simulation
modified Bessel functions
numerical stability
calorimetric thermal voltage converter
ac-dc transfer difference
Opis:
The article presents precision and numerically stable method of calculation of the characteristic impedance of cylindrical multilayer waveguides used in high-precision wideband measuring instruments and standards, especially calculable thermal converters of AC voltage and precision wideband current shunts. Most of currently existing algorithms of characteristic impedance calculation of such waveguides are based upon approximations. Unfortunately, application of such methods is limited to waveguides composed of a specific, usually low number of layers. The accuracy of approximation methods as well as the number of layers is sometimes not sufficient, especially when the coaxial waveguide is a part of precision measurement equipment. The article presents the numerically stable matrix analytical formula using exponentially scaled modified Bessel functions to compute characteristic impedance and its components of the cylindrical coaxial multilayer waveguides. Results obtained with the developed method were compared with results of simulations made using the Finite Element Method (FEM) software simulations. Very good agreement between results of those two methods were achieved.
Źródło:
International Journal of Electronics and Telecommunications; 2022, 68, 3; 527--533
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency improvement due to direct torque and flux three levels three areas control method applied to small hydroelectric power plant
Autorzy:
Kulikowski, K.
Sikorski, A.
Powiązania:
https://bibliotekanauki.pl/articles/200033.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
asynchronous machine
AC/DC/AC converter
DC/AC converter
DTC
flux control
Opis:
The paper presents a description of a new DTFC3L3A (direct torque and flux control three levels three areas) control method of induction machine as well as its comparison with the DTC method. The basis for the comparison is the switching frequency of described methods. The proposed method is optimized to reduce number of switchings (which is proportional to switching power losses) in static state, as well as it takes into account the angle which makes it possible to obtain a sinusoidal shape of flux within range of low angular frequencies of an asynchronous machine. The paper includes the results of experiments performed on a three level DC/AC inverter for both control methods.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 569-574
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies