The paper presents a description of a new DTFC3L3A (direct torque and flux control three levels three areas) control method of induction machine as well as its comparison with the DTC method. The basis for the comparison is the switching frequency of described methods. The proposed method is optimized to reduce number of switchings (which is proportional to switching power losses) in static state, as well as it takes into account the angle which makes it possible to obtain a sinusoidal shape of flux within range of low angular frequencies of an asynchronous machine. The paper includes the results of experiments performed on a three level DC/AC inverter for both control methods.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies