Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Cooling water" wg kryterium: Temat


Tytuł:
Impact of Coolant Water Flow Rate and Temperature Underside Cooling Slope on Solidification with Microstructure and Mechanical Properties of Casted AZ91 Mg Alloy
Autorzy:
Sahu, Sambeet
Kund, Nirmal
Powiązania:
https://bibliotekanauki.pl/articles/28099567.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
coolant water flow rate
coolant water temperature
cooling slope
microstructure
mechanical properties
Opis:
Present study describes about the effect of coolant water flow rate and coolant water temperature underside cooling slope on structural characteristics of casted AZ91 Mg alloy. Here, over the cooling slope, hot melt flows from top to bottom. Additionally, under the cooling slope, coolant water flows from bottom to top. Slurry gets obtained at bottom of cooling slope by pouring AZ91 Mg melt from top of the slope. Coolant water flow rate with coolant water temperature underside cooling slope warrant necessary solidification and shear to obtain AZ91 Mg slurry. Specifically, slurry at 5 different coolant water flow rates (4, 6, 8, 10, 12 lpm) and at 5 different coolant water temperatures (15, 20, 25, 30, 35°C) underside cooling slope are delivered inside metal mould. Modest coolant water flow rate of 8 lpm with coolant water temperature of 25°C (underside cooling slope) results fairly modest solidification that would enormously contribute towards enhanced structural characteristics. As, quite smaller/bigger coolant water flow rate/temperature underside cooling slope would reason shearing that causes inferior structural characteristics. Ultimately, favoured microstructure was realized at 8 lpm coolant water flow rate and 25°C coolant water temperature underside cooling slope with grain size, shape factor, primary α-phase fraction and grain density of 63 µm, 0.71, 0.68 and 198, respectively. Correspondingly, superior mechanical properties was realized at 8 lpm coolant water flow rate and 25°C coolant water temperature underside cooling slope with tensile strength, elongation, yield strength and hardness of 250 MPa, 8%, 192 MPa and 80 HV, respectively.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 2; 673--680
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Technological System for Using Waste Warm Water from Energy Facilities for Effective Agriculture
Autorzy:
Turcheniuk, Vasil
Rokochinskiy, Anatoliy
Kuzmych, Lyudmyla
Volk, Pavlo
Koptyuk, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2097754.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
waste water heat
soil temperature
soil heating
water regime
recycling
cooling
Opis:
The waste warm waters from power plants, owing to their temperature regime (25–38°C) and the volumes of discharge, allow for their use for heating of open ground areas in agriculture. Underground heating by such water is a new, special heat and irrigation method which enables not only purposeful regulation of temperature conditions of the crop growing environment, but also dissipates heat in the soil, thus cooling the water for its reuse. This makes it possible to reduce the thermal pollution of water sources.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2022, 69, 1; 13-25
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Temperature Influence on the Performance of PV/T Cell under Jordan Climate Conditions
Autorzy:
Al-Odat, Mohammed Qassim
Powiązania:
https://bibliotekanauki.pl/articles/2202185.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PV module
electrical conversion
electrical efficiency
water cooling
cooling
cell temperature
Opis:
The electrical performance and the productivity of PV module depend on two main parameters, i.e. the radiation intensity and the cell operating temperature. The module electrical efficiency and productivity are significantly reduced as its temperature increases. Accordingly, cooling of PV modules is one of the most effective techniques to obtain higher efficiency and productivity as well as to reduce the degradation modes of PV modules due to high temperatures. This research work presents an experimental study carried out to investigate the effect of PV module cooling on the performance of PV module under Irbid city (Jordan) climate conditions. It was found that the electrical efficiency and the productivity of the PV modules were approximately enhanced by 14%. Therefore, water cooling of the PV modules is essential to enhance their performance.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 80--88
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of waste hot water utilisation to improve the temperature conditions for growing plants
Autorzy:
Turcheniuk, Vasil
Rokochinskiy, Anatoliy
Kuzmych, Lyudmyla
Volk, Pavlo
Koptyuk, Roman
Romanyuk, Ivan
Voropay, Galyna
Powiązania:
https://bibliotekanauki.pl/articles/2174361.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
cooling
recycling
soil heating
soil temperature
waste water heat
water regime
Opis:
One of the rational ways of energy saving is to use the heat of wastewater from energy companies for open ground heating and cultivation crops. The most significant sources of heat are thermal and nuclear power plants that produce low-thermal waters of 28-35°C. Heating of the ground with the use of circulating warm water allows to increase temperature at all points of the soil profile. The maximum thermal effect from heating ground is observed at the depth of pipe heaters (7.3- 11.1°C). Ground heating allows to extend the growing season for crops by 3-4 weeks, which can expedite harvesting and thus maximise the harvest. In natural moisture conditions, ground heating does not lead to significant reduction of moisture reserves in the active layer throughout the growing period. There is a redistribution of moisture in a soil profile. It decreases in the zone of pipe heaters and redistributes toward the top. The formation of the nutrient regime changes, the content of mobile phosphorus and potassium, and nitrate nitrogen increases, whereas the content of ammonia nitrogen is reduced. Ground heating is a new special heat reclamation technique. It allows not only to control temperature of the agricultural crop environment, but also to dissipate heat in the ground, and promote the utilisation of waste heat and the stabilisation of the environment.
Źródło:
Journal of Water and Land Development; 2022, 54; 94--100
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water trophy assessment of the cooling system of the “Dolna Odra” power plant on the basis of algae indicator organisms
Ocena trofii wód układu chłodzącego elektowni „Dolna Odra” na podstawie składu jakościowego organizmów wskaźnikowych glonów
Autorzy:
Kowalski, Wojciech
Komarzewska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2183584.pdf
Data publikacji:
2022-11-14
Wydawca:
Uniwersytet Pedagogiczny im. Komisji Edukacji Narodowej w Krakowie
Tematy:
wody pochłodnicze
gatunki wskaźnikowe
fitoplankton
wskaźnik saprobowy
trofia wodna infrastruktury hydrologicznej elektrowni
after-cooling water
indicator species
phytoplankton
saprobic index
water trophy of the powerplant’s hydrological infrastructure
Opis:
The paper presents the results of water trophy assessment from various stations of the cooling system of the “Dolna Odra” (Poland) power plant. The assessment was made based on the indicator phytoplankton species collected four times at four sites located in different parts of the hydrological system cooling the technical infrastructure of the power plant. The sites were characterised by water with a natural temperature for individual seasons, as well as by thermals changed as a result of the discharge of cooling waters. For each site, the saprobic index was calculated based on indicator species. The analysis showed that the changes in trophic conditions, both in waters with changed thermals and in waters not subject to the influence of after-cool waters, are not subject to significant changes. The waters of all studied sites in the analysed periods of the year should be classified according to Sladeček and Sládečková (1996) to the waters of the β–mesosaprobic zone, with a saprobic index value ranging from 1.51 to 2.50 (average S = 2.0). This zone is characterised by the course of biochemical processes under aerobic conditions, as a result of which complete oxidation of the intermediate products of decomposition of organic compounds takes place.
W pracy przedstawiono wyniki oceny trofii wód z różnych stanowisk układu chłodniczego elektrowni „Dolna Odra” (Polska). Oceny dokonano w oparciu o wskaźnikowe gatunki fitoplanktonu zebranego w czterech terminach roku na czterech stanowiskach, zlokalizowanych w różnych częściach systemu hydrologicznego, schładzającego infrastrukturę techniczną elektrowni. Stanowiska charakteryzowały się wodami o temperaturze naturalnej dla poszczególnych pór roku, jak i zmienną termiką w wyniku zrzutu wód pochłodniczych. Dla każdego stanowiska obliczono indeks saprobowy na podstawie gatunków wskaźnikowych. Analiza wykazała, że zmiany w zakresie trofii, zarówno w wodach o zmienionej termice, jak i wodach nie podlegających oddziaływaniu wód pochodniczych, nie ulegają istotnym zmianom. Wody wszystkich badanych stanowisk w analizowanych okresach roku należy zaklasyfikować wg Sladeček i Sládečková (1996) do wód strefy β–me- zosaprobowej, mających wartość indeksu saprobowości w granicach od 1,51 do 2,50 (średnio S = 2,0). Strefa ta charakteryzuje się przebiegiem procesów biochemicznych w warunkach aerobowych, w wyniku których zachodzi całkowite utlenienie pośrednich produktów rozkładu związków organicznych.
Źródło:
Annales Universitatis Paedagogicae Cracoviensis Studia Naturae; 2022, 7; 145-170
2543-8832
2545-0999
Pojawia się w:
Annales Universitatis Paedagogicae Cracoviensis Studia Naturae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elementy indukcyjne i transformatory chłodzone wodą
Induction elements and transformers water cooled
Autorzy:
Łukiewski, Mirosław
Łukiewska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/2056417.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformator
dławik
chłodzenie wodne
panel chłodzący
chłodnica rurowa
rdzenie proszkowe
materiały amorficzne
materiały nanokrystaliczne
transformer
choke
water cooling
cooling panel
tubular cooler
powder cores
amorphous material
nanocrystalline material
Opis:
W artykule omówiono wybrane zagadnienia konstrukcyjne i technologiczne stosowane w produkcji elementów indukcyjnych i transformatorów z chłodzeniem wodnym. Przedstawiono wyniki symulacji wpływu rodzaju materiału magnetycznego rdzenia na wymiary dławika filtru sinusoidalnego typu SinECOTM pracującego przy częstotliwości sieciowej oraz dla transformatora mocy typu 1TTFW pracującego przy częstotliwości 10kHz. Przedstawiono również konstrukcję dławika z odczepami typu 1RTFW przeznaczonego do pracy z częstotliwością 25kHz. Parametry obliczeniowe wyznaczono wykorzystując oprogramowanie projektowe firmy RALE Engineering GmbH.
In this article selected issues related to the construction and technology of the water cooling transformers and induction elements were discussed. The impact of the magnetic core material type on the size of the SinECOTM type choke working with 50Hz frequency and 1TTFW type power transformer working with 10kHz frequency was simulated. Moreover, the construction of the 1RTFW type choke working with 25 kHz frequency was introduced. The parameters were simulated using design software by RALE Engineering GmbH.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2021, 2, 126; 71--76
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of cooling water temperature on the performance of a BWR nuclear power plant
Autorzy:
Laskowski, Rafał
Theimech, Mohamad
Uzunow, Nikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2195750.pdf
Data publikacji:
2021
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
nuclear power plant
cooling system
cooling water temperature
boiling water reactor
BWR
elektrownia jądrowa
układ chłodzenia
temperatura wody chłodzącej
reaktor wrzący
Opis:
Although PWR reactors make up the large majority of the world's nuclear power plants, BWR reactors also have a share in this industry. It is difficult to find data on the performance of a BWR power plant in off-design and variable load conditions in the literature. Therefore, the paper presents how cooling water temperature affects the efficiency and power output of a BWR unit. The qualitative effect of changes and the trend related to the effect of cooling water temperature on the performance of the power plant are known, but the quantitative effect has to be determined for specific power units. Depending on the location of the nuclear power plant, various temperatures of cooling water for use in condensers and thus various operating conditions of the cooling system can be achieved. To analyze how cooling water temperature affects the performance of the power unit, a model of a BWR power plant was developed using the Ebsilon software. The model was based on data provided in [1] concerning LaSalle County Nuclear Generating Station. Calculations showed that within the examined range of cooling water temperatures at the condenser inlet between 10 and 28oC the gross power output of the unit decreases by 91.405 MW and the gross efficiency drops by 2.773 percentage points.
Źródło:
Modern Engineering; 2021, 3; 5--13
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układy poligeneracyjne do skojarzonej produkcji energii elektrycznej, ciepła i chłodu
Polygeneration systems for cogeneration of electricity, heat and cooling
Autorzy:
Nowak, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2069863.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
sorpcja
produkcja chłodu i wody pitnej
poligeneracja
polygeneration
sorption
cooling and drinking water production
Opis:
Najpopularniejszym rozwiązaniem trójgeneracyjnym jest skojarzenie generatora energii elektrycznej, najczęściej silnika gazowego, z węzłem odbioru ciepła oraz z absorpcyjnym agregatem chłodniczym wykorzystującym do produkcji wody lodowej wodę gorącą. Rozwiązania tego typu odznaczają się wysoką efektywnością energetyczną, jak również doskonałą elastycznością pracy, bowiem w okresie letnim nadwyżka produkowanego ciepła wykorzystywana jest przez agregat absorpcyjny do produkcji chłodu, przez co znacznej redukcji ulega zapotrzebowanie na energię elektryczną na cele chłodnicze. W pracy zaprezentowano system do skojarzonej produkcji energii elektrycznej, ciepła i chłodu z dodatkową funkcją odsalania wody oraz oczyszczania ścieków. System pozwala na osiągnięcie bardzo wysokiej efektywności energetycznej dzięki racjonalnemu wykorzystaniu ciepła odpadowego generowanego przez silniki Diesla.
The most popular tri-generation solution is the combination of an electricity generator, most often a gas engine, with a heat collection node and an absorption chiller that uses hot water to produce chilled water. Solutions of this type are characterized by high energy efficiency, as well as excellent flexibility of operation, because during the summer the surplus heat produced is used by the absorption chiller to produce cooling, which significantly reduces the need for electricity for cooling purposes. The paper presents a system for cogeneration of electricity, heat and cooling with an additional function of water desalination and sewage treatment. The system allows to achieve very high energy efficiency through rational use of waste heat generated by diesel engines.
Źródło:
Energetyka Rozproszona; 2021, 4; 63--70
2720-0973
Pojawia się w:
Energetyka Rozproszona
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste Heat Recovery from Servers Using an Air to Water Heat Pump
Autorzy:
Lipiński, Seweryn
Duda, Michał
Górski, D.
Powiązania:
https://bibliotekanauki.pl/articles/2069738.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
air-water heat pump
server cooling
waste heat
heat recovery
domestic hot water
Opis:
The analysis of advisability and profitability of using an air to water heat pump for the purpose of waste heat recovery from servers being used as cryptocurrency mining rigs, was performed. To carry out such an analysis, the cooling unit of the computing server was connected to the heat pump, and the entire system was adequately equipped with devices measuring parameters of the process. Performed experiments proves that the heat pump coefficient of performance (COP) reaches satisfactory values (i.e., an average of 4.21), what is the result of stable and high-temperature source of heat at the pump inlet (i.e., in the range of 29.9-34.1). Economic analysis shows a significant reduction in the cost of heating domestic hot water (by nearly 59-61%). The main conclusion which can be drawn from the paper, is that in a case of having a waste heat source in a form of a server or similar, it is advisable to consider the purchase of air-to-water heat pump for the purpose of domestic hot water heating.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2021, 24(1); 105--113
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative Study of 2060-T8 Al-Li Alloy Friction Stir Welded Joints Between Natural Cooling and Water Cooling
Autorzy:
Ma, Lin
Niu, Shiyu
Ji, Shude
Gong, Peng
Powiązania:
https://bibliotekanauki.pl/articles/355846.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
2060-T8 Al-Li alloy
friction stir welding
water cooling
microstructure
mechanical properties
Opis:
2060-T8 Al-Li alloy was friction stir butt welded under natural and water cooling conditions. Microstructures and mechanical properties of the welding joints were mainly compared and discussed. By spraying water on the top surface of stir zone, the grain size was reduced, attributing to the improvement of microhardness. The maximum tensile strength under the water cooling reached 461.1 MPa. The joint fractured at the stir zone due to the thickness reduction and the joint softening. The fracture surface consisted of many dimples with various sizes, indicating the typical ductile fracture. The strategy to apply the low heat input at the welding stage and high cooling rate at the cooling stage during FSW is necessary to obtain a high-quality FSW joint.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 1; 305-312
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the average and local boundary condition of heat transfer during cooling with a water spray under surface boiling
Autorzy:
Jasiewicz, Elżbieta
Hadała, Beata
Malinowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/29520235.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
water spray cooling
heat transfer coefficient
heat flux
inverse problem
heat conduction equation
Opis:
The study determined the local and average heat transfer coefficient and the heat flux on the surface of a cylinder cooled with a water nozzle. The inverse method was used to identify the heat transfer coefficient. An objective function was defined to determine the distance between the measured and calculated temperatures. Two models describing the heat transfer coefficient on the cooled surface were considered. The first model described changes in the heat transfer coefficient as a function of the sample radius and cooling time, and the second one assumed the dependence of the heat transfer coefficient solely on time. Numerical simulations showed significant differences in the determined heat transfer coefficients depending on the adopted model of the boundary condition. The performed tests included experimental temperature measurements at selected points of the sensor, numerical simulations of temperature changes, and the inverse solution.
Źródło:
Computer Methods in Materials Science; 2020, 20, 4; 147-155
2720-4081
2720-3948
Pojawia się w:
Computer Methods in Materials Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coolant pump for compression-ignition aircraft engine
Autorzy:
Gęca, Michał Jan
Pietrykowski, Konrad
Barański, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/133232.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
diesel engine
opposed-piston engine
aircraft propulsion system
cooling system
water pump
silnik wysokoprężny
silnik o tłokach przeciwbieżnych
układ napędowy samolotu
układ chłodzenia
pompa wody
Opis:
The article presents an analysis of the design of cooling liquid pumps for a compression-ignition aircraft engine. A 100 kW twin-charged, two-stroke, liquid-cooled engine has 3 cylinders and 6 opposed-pistons. In the first part of the study, the amount of heat needed to be removed by the cooling system was estimated to obtain the required volumetric flow rate. Then, the design of automotive cooling liquid pumps for compression-ignition engines with a Common Rail power supply system and power of about 100 kW was analyzed. The aim of the analysis was to select a suitable pump for applications in the aircraft compression-ignition engine. 5 constructions of different shape, diameter and width of the working rotor were selected. The pressure and volume flow rate were determined for a given rotational speed of the pump on a specially built stand. The operation maps of individual pumps were created to select the most efficient types of pumps.
Źródło:
Combustion Engines; 2019, 58, 4; 52-57
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Klasyfikacja stanu przybrzeżnych wód morskich na Ukrainie na przykładzie Morza Azowskiego w rejonie Mariupola
Classification of the State of narine coastal waters in Ukraine in the example of the Sea of Azov in the Mariupol Region
Autorzy:
Neverova-Dziopak, E.
Dan, O.
Powiązania:
https://bibliotekanauki.pl/articles/1203874.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
Morze Azowskie
huta
ścieki chłodnicze
ścieki technologiczne
ocena stanu wód
ocena oddziaływania na środowisko
wskaźnik jakości wody
wskaźnik zanieczyszczenia wody
Sea of Azov
steelworks
cooling wastewater
technological waste water
water status assessment
environmental impact assessment
Water Quality Index
Water Pollution Index
Integrated Ecological State Index
Opis:
Morze Azowskie jest najmniejszym i najpłytszym morzem na świecie o małym zasoleniu. Takie właściwości powodują jego podatność na degradację pod wpływem działalności antropogenicznej. Jednym z głównych źródeł zanieczyszczeń Morza Azowskiego jest huta „Azovstal” w Mariupolu (Ukraina). Negatywny wpływ huty jest związany przede wszystkim z dużą ilością odprowadzanych do morza ścieków chłodniczych i technologicznych. W pracy przedstawiono wyniki oceny oddziaływania ścieków z huty na jakość wody morskiej i sytuację ekologiczną w strefie ich odprowadzania, dokonanej na podstawie metod stosowanych w Ukrainie oraz obowiązujących standardów jakości wód powierzchniowych. Kompleksową ocenę dokonano na podstawie wartości trzech wskaźników jakości wody morskiej – wskaźnika jakości wody (WJW), wskaźnika zanieczyszczenia wody (WZW) oraz zintegrowanego wskaźnika stanu ekologicznego (ZWSE), a także z uwzględnieniem tak zwanej zasady sumowania. Na podstawie wyników przeprowadzonej oceny wykazano, że odprowadzanie ścieków z huty „Azovstal” prowadzi do znacznego wzrostu stopnia zanieczyszczenia wód w strefie przybrzeżnej Morza Azowskiego, co stanowi zagrożenie ekosystemu morskiego i ogranicza wszystkie rodzaje użytkowania wody.
The Sea of Azov is the smallest and shallowest sea in the world with low salinity. Such properties determine its susceptibility to degradation due to anthropogenic activities. The Azovstal Iron & Steel Works in Mariupol (Ukraine) is one of the main sources of pollution of the Azov Sea. Adverse impact of the steelworks is associated primarily with the large amount of technological and cooling wastewater discharged into the sea. The paper presents the impact assessment results of wastewater discharge on the sea water quality and the ecological conditions in the discharge zone. The assessment was performed using local Ukrainian methodologies as well as applicable surface water quality standards. The comprehensive assessment was based on the three numerical integrated indicators of sea water quality: the Water Quality Index (WJW), the Water Pollution Index (WZW), the Integrated Ecological State Index (ZWSE), and the so called principle of aggregation. Based on the assessment results it was demonstrated that the wastewater discharge from the Azovstal Iron & Steel Works leads to significant increase in water pollution in the coastal zone which brings threat to the marine ecosystem and limits all types of water consumption.
Źródło:
Ochrona Środowiska; 2018, 40, 3; 29-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of environmental and human impacts of using Strong Alkaline Water for cooling during machining
Autorzy:
Da Silva, P.
Tanabe, I.
Junior, D. C. R.
Takahashi, S.
Powiązania:
https://bibliotekanauki.pl/articles/99481.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
eco-friendly
strong alkaline water
emission
cooling
Opis:
An eco-friendly manufacturing approach is important for the environment. Enhancing machining performances is not only required to improve product’s quality, time saving, and reduces costs; it is also contributed to the environmental protection efforts. Cooling is important aspect for obtaining this purpose. Therefore the benefits of Strong Alkaline Water (SAW) cooling method was assessed and compared with conventional wet cutting method. An experiment was performed at Nagaoka University of Technology machining centre. Three machine tools including a milling machine, a drilling machine and a turning machine were used. The study shows that using SAW for cooling is far more efficient than conventional cooling method. It reduces annual global warming potential by 72.95%, acidification potential 98.18%, ozone depletion potential 99.6%, smog formation potential 85.71% and human toxicity potential 42.86% compare with conventional method. The study concludes that besides inhibiting corrosion, prolonging tool life, improving surface roughness of final cutting and reducing energy usage, strong alkaline water cooling is an environmentally friendly approach and has positive impact on human health.
Źródło:
Journal of Machine Engineering; 2018, 18, 1; 45-60
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies