Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "COD fractions" wg kryterium: Temat


Tytuł:
Analysis of COD Fractions in Raw Wastewater Flowing into Small and Large Wastewater Treatment Plants
Autorzy:
Ignatowicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/124764.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD fractions
treatment plants
rotary biological contactor
constructed wetland
activated sludge
Opis:
The aim of the study was to determine and compare the amount and biodegradability of organic compounds determined by the COD measure contained in raw sewage inflowing to small sewage treatment plants and municipal sewage wastewater treatment plants with high personal equivalent (P.E.). Raw sewage samples were collected in three chosen facilities. The research presented in the article were conducted with two small plants: constructed wetland plant with an average capacity of 4 m3/d and the treatment plant with rotary biological contactor (RBC) with an average capacity of 5 m3/d. Also big municipal wastewater treatment plant (WWTP) with activated sludge in Bialystok with a capacity of about 63 000 m3/d was checked. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was founded in raw sewage in small wastewater treatment plants (CW and RBC).
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 197-201
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Bakery Sewage Treatment Process Options Based on COD Fraction Changes
Autorzy:
Struk-Sokolowska, J.
Tkaczuk, J.
Powiązania:
https://bibliotekanauki.pl/articles/125274.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
municipal
bakery
food industry
COD fractions
activated sludge process
Opis:
Municipal WWTPs often receive industrial wastewater including the bakery sewage. The effluent of the bakery industry has a high biological oxygen demand (BOD). In addition to high BOD, this wastewater contains high chemical oxygen demand (COD), total Kjeldahl nitrogen (TKN) and is characterized by a dark color. The effect of bakery wastewater contribution on the COD fraction changes in the municipal sewage is presented in this paper. The study was conducted in July 2016 in a WWTP located in Lipsk, East-North Poland. The sewage receiver is the Biebrza River. The volume contribution of bakery wastewater is 10%. The analytical results were used to compute the percentage value contribution of individual COD fractions in wastewater. During the study, the following fractions were identified: SS – COD of readily-biodegradable dissolved organic matter, SI – COD of non-biodegradable dissolved organic matter, XS – COD of slowly-biodegradable non-soluble organic matter, XI – COD of non-biodegradable non-soluble organic matter. The method used for the COD fraction determination in wastewater was developed based on the ATV 131P guidelines (ATV-DVWK-A131P). The aim of the study was to determine the effect of bakery wastewater contribution on the COD fraction changes during the technical scale biological wastewater treatment with an activated-sludge process. The percentage contributions of individual COD fractions in wastewater were compared with the shares in the wastewater from other food industries (dairy, olive mill, tomato, sugar beet, potato processing, winery). In raw wastewater, the XS fraction was dominant 44.2%. SS fraction was 38.8%. In raw wastewater, the SI, XI fractions ranged from 2.3 to 14.8%. In the effluent the SS fraction was not noted, which is indicative of microorganisms consumption. The WWTP effluents mostly (43.4%) contained slowly-biodegradable non-soluble organic matter (XS). Non-biodegradable dissolved organic matter (SI fraction) had a high share of 42.3%.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 226-235
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian udziału frakcji ChZT w procesie denitryfikacji z zewnętrznym źródłem węgla
Analysis of COD Fractions Changes During Denitrification Process with External Carbon Source
Autorzy:
Smyk, J.
Ignatowicz, K.
Piekarski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1813840.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
frakcje ChZT
zanieczyszczenia biodegradowalne
zanieczyszczenia niebiodegradowalne
denitryfikacja
zewnętrze źródła węgla
wastewater treatment
COD fractions
pollution biodegradable
denitrification
external carbon source
Opis:
W artykule przedstawiono wyniki badań dotyczące stężeń frakcji ChZT w mechaniczno-biologicznej oczyszczalni ścieków o wielkości >1000 000 RLM, zlokalizowanej w Białymstoku. Dodatkowo oznaczono BZT5, azot amonowy, azotany (V), azot ogólny oraz fosfor ogólny. Analizowano próbki ścieków surowych, z komory predenityfikacji, komory defosfatacji, komory denitryfikacji w miejscu dawkowania zewnętrznego źródła węgla - Brenntaplus VP1, komory denitryfikacji w pewnej odległości od miejsca dawkowania zewnętrznego źródłem węgla oraz ścieki oczyszczone. Metodyka wyznaczania stężeń frakcji ChZT została opracowana na podstawie wytycznej ATV-131. Podczas wykonywania analizy określono następujące frakcje: nierozpuszczalnej materii organicznej, biologicznie wolno rozkładalnej (XS), rozpuszczonej materii organicznej, biologicznie łatwo rozkładalnej, (SS), nierozpuszczalnej materii organicznej, biologicznie trudno rozkładalnej (XI) i rozpuszczonej materii organiczne, biologicznie nierozkładalnej (SI). Przeprowadzona analiza pokazała, że w ściekach surowych doprowadzanych do oczyszczalni ścieków ponad 80% materii organicznej określanej jako ChZT stanowiły frakcje biologicznie rozkładalne XS i SS. Niskie stężenie udziału procentowego materii organicznej we frakcji SS oraz XS w ściekach oczyszczonych świadczy o przyswajaniu tych frakcji przez mikroorganizmy biorące udział w procesach usuwania związków azotu i fosforu. Niskie stężenie i procentowy udział materii organicznej we frakcji ChZT nierozpuszczalnej nierozkładalnej XI w ściekach oczyszczonych świadczy o wbudowywaniu jej w kłaczki osadu czynnego. Układ technologiczny oczyszczania ścieków analizowanej oczyszczalni nie miał wpływu na zmianę stężenia rozpuszczonej frakcji biologicznie nierozkładalnej SI w ściekach. Niskie stężenie azotanów (V) w ściekach oczyszczonych zostało uzyskane z powodu dawkowania zewnętrznego źródła węgla. Usuwanie zanieczyszczeń w oczyszczalni ścieków w Białymstoku przebiega prawidłowo i jest zgodne z polskimi regulacjami prawnymi.
The article presents results of analysis on concentration of COD fractions in mechanical-biological treatment plant with a size > 1000 000 RLM, located in Bialystok. Additionally determined BOD5, ammonia nitrogen, nitrates (v), total nitrogen and total phosphorus. The samples were tested: raw sewage, from the chamber pre-denitrification, from chamber of phosphorus removal, from the denitrification chamber in place of the dosage of external carbon source - Brenntaplus VP1, from the denitrification chamber at a distance from the place of dosing external carbon source and samples of treated sewage. Methodology for determining the fraction of COD was developed based on the guidelines of ATV-131. During the studyidentified the followingfractions: SS – COD of soluble organic easily biodegradable substances, SI – COD of soluble organic non-biodegradable substances, XS – COD of organic slowly biodegradable suspensions, XI – COD of organic non-biodegradable suspensions. Based on the study was formed the following conclusions that in raw wastewater, the dominating percent-age was recorded for fractions of biodegrad-able contaminants (SS and XS) reaching about 80% of the total COD of sewage. Low share content of organic matter in the fraction of SS and XS treated wastewater shows the absorption of these fractions by the microorganisms involved in processes for the removal of nitrogen and phosphorus. Low content of quantitative and percentage of organic compounds in the fraction of undissolved COD irreducible XI in treated wastewater, testifies to its incorporation in activated sludge floc. The technological system of wastewater treatment plant does not change the concentration of the dissolved fraction in the wastewater biologically decomposable SI. Low concentration of nitrates (V) in the treated wastewater was obtained by dosing an external source of carbon. Removal of pollutants in waste watertreatment plant in Bialystok is correct and is in line with the requirements of Polish law.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 760-776
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
COD fractions - methods of measurement and use in wastewater treatment technology
Frakcje CHZT - metody pomiaru oraz zastosowanie w technologii oczyszczania ścieków
Autorzy:
Myszograj, S.
Płuciennik-Koropczuk, E.
Jakubaszek, A.
Świętek, A.
Powiązania:
https://bibliotekanauki.pl/articles/396702.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
COD fractions
raw wastewater
methods of measurement
frakcje ChZT
ścieki surowe
metody pomiaru
Opis:
The paper presents the results of studies concerning the designation of COD fraction in raw wastewater. The research was conducted in four municipal mechanical-biological sewage treatment plants and one industrial sewage treatment plant. The following fractions of COD were determined: non-biodegradable (inert) soluble SI, biodegradable soluble fraction SS, particulate slowly degradable XS and particulate non-biodegradable XI. The methodology for determining the COD fraction was based on the ATV-A131 guidelines and Łomotowski-Szpindor methodology. The real concentration of fractions in raw wastewater and the percentage of each fraction in total COD are different from data reported in the literature.
W artykule przedstawiono wyniki badań, których celem było wyznaczanie frakcji ChZT w ściekach surowych. Badania przeprowadzono w czterech komunalnych mechaniczno-biologicznych oczyszczalniach ścieków i oczyszczalni ścieków przemysłowych. Określono następujące frakcje ChZT: inertna rozpuszczona SI, biodegradowalna rozpuszczona SS, związana w zawiesinie biologicznie łatworozkładalnej XS i związana w zawiesinie nieulegająca biodegradacji XI. Metodologia określania frakcji ChZT została oparta na wytycznych ATV-A131 i metodologii Łomotowskiego-Szpindora. Uzyskany udział frakcji w całkowitym ChZT w ściekach surowych różnił się od danych literaturowych.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 24(1); 197-208
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
COD fractions in mechanical-biological wastewater treatment plant
Frakcje ChZT w mechaniczno-biologicznej oczyszczalni ścieków
Autorzy:
Płuciennik-Koropczuk, E.
Jakubaszek, A.
Myszograj, S.
Uszakiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/396234.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater
COD fractions
ASM models
organic substances biodegradable
organic substances non-biodegradable
ścieki
frakcje ChZT
modele ASM
substancje organiczne biodegradowalne
substancje organiczne niebiodegradowalne
Opis:
The paper presents results of studies concerning the designation of COD fraction in the raw, mechanically treated and biologically treated wastewater. The test object was a wastewater treatment plant with the output of over 20,000 PE. The results were compared with data received in the ASM models. During investigation following fractions of COD were determined: dissolved non-biodegradable SI., dissolved easily biodegradable SS, in organic suspension slowly degradable XS. and in organic suspension non-biodegradable XI. Methodology for determining the COD fraction was based on the guidelines ATV-A 131. The real percentage of each fraction in total COD in raw wastewater are different from data received in ASM models.
W artykule przedstawiono wyniki badań dotyczące wyznaczania frakcji ChZT w ściekach surowych, mechanicznie oczyszczonych oraz oczyszczonych. Obiektem badań była mechaniczno-biologiczna oczyszczalnia ścieków o wielkości powyżej 20 000 RLM. Uzyskane wyniki porównano z założeniami modeli biokinetycznych ASM. W badaniach wyznaczono następujące frakcje: rozpuszczone substancje organiczne, biologicznie nierozkładalne SI, rozpuszczone substancje organiczne, biologicznie łatwo rozkładalne SS., substancje organiczne w zawiesinie, biologicznie wolno rozkładalne XS. oraz substancje organiczne w zawiesinie, biologicznie trudno rozkładalne XI. Metodyka wyznaczania frakcji ChZT została opracowana w oparciu o wytyczne ATV-131. Wyznaczone w badaniach wartości procentowego udziału frakcji w badanych ściekach surowych różnią się od założeń modeli ASM.
Źródło:
Civil and Environmental Engineering Reports; 2017, No. 24(1); 209-219
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena przemian związków węgla, azotu i fosforu podczas oczyszczania ścieków komunalnych
Assessment of carbon, nitrogen and phosphorus transformations during municipal wastewater treatment
Autorzy:
Przywara, L.
Powiązania:
https://bibliotekanauki.pl/articles/400965.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
zanieczyszczenia organiczne
frakcje ChZT
oczyszczanie mechaniczno-biologiczne
azot
fosfor
organic matter
COD fractions
mechanical-biological treatment
nitrogen
phosphorus
Opis:
Prawidłowa eksploatacja oczyszczalni wymaga monitorowania parametrów procesu oczyszczania, jak i efektywności poszczególnych jego etapów. Wymagania prawne dotyczą nie tylko związków organicznych (BZT5, ChZT) i zawiesin ogólnych, ale również wysokoefektywnego usuwania związków biogennych: azotu i fosforu. Efektywność usuwania związków biogennych zakłóca m.in wahania temperatury, jakość ścieków, problemy z działaniem osadu czynnego. Celem badań było określenie zmian zawartości związków organicznych, związków azotu i fosforu w poszczególnych etapach mechaniczno-biologicznego oczyszczalnia ścieków. Próbki pobierano zgodnie z przepływem wzdłuż przekroju oczyszczalni: ścieki surowe, po mechanicznym oczyszczeniu, po komorze predenitryfikacji, defosfatcji, denitryfikacji, ścieki oczyszczone. Innym aspektem prowadzonych badań było wyznaczenie frakcji ChZT oraz ich zmian w ściekach komunalnych, po kolejnych etapach mechaniczno-biologicznego oczyszczania. Frakcjonowanie umożliwia wyodrębnienie rozpuszczonych i nierozpuszczalnych substancji organicznych, uwzględniając dodatkowo ich biodegradowalność, a także brak podatności na biologiczny rozkład, co stanowić bardzo istotny element kontroli procesów zachodzących podczas oczyszczania ścieków.
Proper exploitation of waste water treatment plant is strictly connected with monitoring of basic parameters and effectiveness of particular its stages. Legal requirements include not only organic compounds (BOD5, COD) and general suspensions but also highly effective removal of nutrients: nitrogen and phosphorus. The effectiveness of biogenic compounds removal is hindered by temperature fluctuations, effluent quality, and problems of active sediment. The aim of this study was to show the changes in concentrations of organic compounds, nitrogen and phosphorus in the municipal wastewater after subsequent stages of mechanical-biological treatment. During the research, samples were collected during consecutive stages of wastewater treatment: raw wastewater, wastewater after mechanical treatment, pre-denitrification, dephosphatation, denitrification, nitrification and treated wastewater. Determination of COD fractions, and their changes in the municipal wastewater, after the successive stages of mechanical-biological treatment constituted another aspect of this study. It allows separation of dissolved and non-dissolved organic substances, also taking into account their biodegradability and the lack of susceptibility to biological decomposition. This method can also be very important for the control of processes during wastewater treatment.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 4; 142-147
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany frakcji ChZT ścieków komunalnych podczas beztlenowego oczyszczania
COD fractions changes of municipal sewage during anaerobic treatment
Autorzy:
Przywara, L.
Adamus, A.
Kuglarz, M.
Grübel, K.
Powiązania:
https://bibliotekanauki.pl/articles/126859.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
frakcje ChZT
oczyszczanie beztlenowe
substancje biodegradowalne
substancje niebiodegradowalne
COD fractions
anaerobic treatment
biodegradable matter
non-biodegradable matter
Opis:
Optymalizacja procesów biologicznego oczyszczania ścieków wymaga coraz więcej informacji dotyczących składu oczyszczanych ścieków. W celu scharakteryzowania zawartości substancji organicznej w trakcie oczyszczania ścieków komunalnych czy przemysłowych stosuje się powszechnie biochemiczne zapotrzebowanie tlenu (BZT), chemiczne zapotrzebowanie tlenu (ChZT), ogólny węgiel organiczny (OWO). Szczegółowa charakterystyka substancji organicznych w ściekach może być osiągnięta przez wyznaczenie frakcji ChZT. Celem badań było wyznaczenie frakcji ChZT oraz ich zmiany w ściekach komunalnych podczas beztlenowego oczyszczania. Efektem zastosowanego beztlenowego procesu oczyszczania ścieków komunalnych była zmiana udziału poszczególnych frakcji ChZT: obniżenie udziału frakcji substancji biologicznie rozkładalnych z 57,0 do 46,4% całkowitego ChZT oraz wzrost udziału związków biologicznie nierozkładalnych z 43,0 do 53,6% całkowitego ChZT dla ścieków z oczyszczalni A oraz obniżenie udziału frakcji substancji biologicznie rozkładalnych z 54,2 do 42,0% całkowitego ChZT oraz wzrost udziału związków biologicznie nierozkładalnych z 45,8 do 58,0% całkowitego ChZT dla ścieków z oczyszczalni B.
The optimization of sewage treatment biological processes requires increasing amount of information concerning the composition of treated sewage. Biological oxygen demand (BOD), chemical oxygen demand (COD) and total organic carbon (TOC) are traditionally used to characterize organic matter in wastewater. Detailed characteristics of organic substances in wastewater can be achieved by determining COD fractions. The aim of this study was to determine COD fractions, and their changes in the municipal sewage during anaerobic treatment. The effect of anaerobic treatment of municipal sewage was the change of COD fractions share, i.e.: decrease in the proportion of biodegradable fraction from 57 to 46% of the total COD and increase in the proportion of biologically decomposable fraction from 43 to 54% of the total COD for wastewater treatment plant A. For wastewater treatment plant B, decrease in the proportion of biodegradable fraction from 54 to 42% of the total COD and increase in the proportion of biologically decomposable fraction from 46 to 58% of the total COD, occur or was observed.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 259-268
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany składu materii organicznej podczas oczyszczania ścieków komunalnych
Changes in organic matter composition during municipal sewage treatment
Autorzy:
Przywara, L.
Adamiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/127545.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
materia organiczna
frakcje ChZT
wody odpadowe
przeróbka osadów
odcieki
organic matter
COD fractions
reject water
Opis:
Efektywność oczyszczania ścieków zależy nie tylko od zastosowanej technologii dostosowanej do jakości dopływających ścieków surowych, ale również od problemów eksploatacyjnych czy gospodarki wodami osadowymi. Obecnie oczyszczalnie nie stosują metod wydzielonego oczyszczania odcieków powstających w trakcie przeróbki osadów i są zawracane na początek ciągu technologicznego oczyszczalni. Wody osadowe ze względu na zawartość substancji organicznej niepodatnej na biodegradację mogą wpływać na efektywność realizowanych procesów oczyszczania. Dlatego też ważne jest nie tylko określenie ogólnej zawartości związków organicznych w ściekach, ale również dokonanie szczegółowej charakterystyki substancji organicznych przez wyznaczenie frakcji ChZT. W niniejszych badaniach przeanalizowano przemiany materii organicznej podczas oczyszczania ścieków w kolejnych etapach mechaniczno-biologicznego oczyszczania ścieków, dokonując analizy składu frakcyjnego materii organicznej. Badania prowadzono na ściekach pochodzących z oczyszczalni pracującej w technologii zintegrowanego usuwania związków organicznych i biogennych. Wykazano m.in., że cyrkulacja odcieków powstających podczas odwadniania osadów powodowała wzrost stężenia trudno rozkładalnej substancji organicznej. Podczas mechaniczno-biologicznego procesu oczyszczania całkowicie uległy zmianie proporcje frakcji Si, Ss, Xi, Xs. Dominującą frakcją w ściekach oczyszczonych była frakcja związków rozpuszczonych nieulegających biologicznemu rozkładowi przez mikroorganizmy - Si. Łącznie frakcje inertne (Si i Xi) w ściekach oczyszczonych stanowiły 76,4% całkowitego ChZT. Udział frakcji Xi na poziomie 16,3% całkowitego ChZT w ściekach oczyszczonych pozwala stwierdzić, że zachodzące procesy oczyszczania działają z dużą efektywnością, na które nie mają wpływu doprowadzane wody osadowe.
Efficiency of wastewater treatment depends not only on the applied technology of wastewater treated, but also on processing problems and management of reject water. Currently, treatment plants do not use methods of separate treatment of reject water generated during the processing of sludge and such residues are returned to the beginning of technological process of treatment. Reject water due to the content of non-biodegradable organic matter can affect the efficiency of the purification process. Therefore, it is important not only to determine the overall content of organic compounds in wastewater, but also the specific characteristics of organic substances, by determining of COD fractions. In this study, fractional composition of organic matter during wastewater treatment in the subsequent stages of mechanical and biological wastewater treatment was analyzed. The wastewater used originated from the plant using integrated removal of organic and biogenic compounds. The circulation of reject water formed during dewatering of sediments, resulted in an increase in the concentration of the hardlybiodegradable organic matter. During mechanical/biological phase of wastewater treatment, the proportions of Si, Ss, Xi, Xs fractions were completely changed. The dominant fraction in purified effluents was a fraction of dissolved and non-biodegradable compounds Si. In total, Si and Xi inert fractions in purified effluent accounted for 76% of the total COD. The fraction of Xi, in purified effluent, in case of processes not influenced by recirculated reject water, amounted for 16% of the total COD. This shows that the cleaning processes occurs with high effectiveness.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 571-580
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie frakcji CHZT w ściekach surowych dopływających do małych i dużych oczyszczalni ścieków
Comparison of the fractions of cod in raw wastewater influent for small and large sewage treatment
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/401888.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
frakcje ChZT
małe oczyszczalnie ścieków
złoża biologiczne
oczyszczalnia hydrofitowa
oczyszczalnia z osadem czynnym
COD fractions
small sewage treatment plants
rotary biological contactor
constructed wetland
treatment with activated sludge
Opis:
W artykule przedstawiono porównanie udziału frakcji ChZT w ściekach surowych w oczyszczalniach do których spływają małe ilości ścieków oraz oczyszczalnię z dużym przepływem. Porównano oczyszczalnię hydrofitową o średniej przepustowości 4 dm3/m, oczyszczalnię ze złożami biologicznymi o średniej przepustowości 8 dm3/m, oraz oczyszczalnię ścieków z osadem czynnym w Białymstoku o przepustowości około 70 000 m3/d. Najniższe udziały procentowe frakcji rozpuszczonych związków biologicznie nierozkładalnych SI w ściekach surowych odnotowano w małych oczyszczalniach ścieków. Na podstawie dostępnych danych niestwierdzono istotnych zależności między frakcjami XI, SS, XS w ściekach surowych a ilością wytwarzanych ścieków.
The article presents a comparison of the share fraction of COD in raw wastewater in treatment plants which flow in a small amount of wastewater and the sewage treatment with high flow. Compared the constructed wetlands with an average capacity of 4 dm3/m,, the treatment plant with biological deposits with an average capacity of 8 dm3/m, and a sewage treatment plant with activated sludge in Bialystok with a capacity of about 70 000 dm3/m. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was reported in raw sewage in small sewage treatment plants. Based on the available data wasn’t found significant correlation between the factions XI, SS, XS in raw sewage and the amount of wastewater.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 191-195
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza frakcji ChZT w procesach mechaniczno-biologicznego oczyszczania ścieków
COD fractions in the process of mechanical-biological treatment sewage
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/399582.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oczyszczalnia mechaniczno-biologiczna
skuteczność usuwania zanieczyszczeń
frakcje ChZT
zanieczyszczenia biodegradowalne
zanieczyszczenia niebiodegradowalne
mechanical-biological treatment
soil removal
fractions of COD
biodegradable pollution
contamination of non biodegradable
Opis:
Celem badań było wyznaczenie frakcji ChZT w ściekach surowych i ich zmian w ściekach po procesach oczyszczania. Badania prowadzono w oczyszczalni ścieków w Białymstoku o RLM>100000. W ściekach surowych w najwyższych stężeniach występowały frakcje w zawiesinie organicznej wolno biodegradowalnej XS (303,7 mg O2/l) oraz związki organiczne rozpuszczone łatwo biodegradowalne SS (263 mg O2/l). W niższych ilościach były frakcje nierozkładalne rozpuszczone i w zawiesinie SI (56 mg O2/l) oraz XI (101,2 mg O2/l). Prawie 80% ChZT całkowitego stanowiły frakcje biologicznie rozkładalne (SS+XS). W ściekach oczyszczonych w najwyższym stężeniu występowała frakcja rozpuszczona niebiodegradowalna SI (56 mg O2/l). Przepływ ścieków przez elementy oczyszczalni spowodował całkowite usunięcie frakcji biologiczne rozkładalnej rozpuszczonej SS. Ponad 94,5% ChZT całkowitego w ściekach oczyszczonych stanowiły frakcje biologicznie nierozkładalne (SI+XI). Ponadto na podstawie przeprowadzonej analizy badań stwierdzono następującą skuteczność usuwania zanieczyszczeń: BZT5 – 99,4%, ChZT – 92,9%, azot ogólny – 93,4%, fosfor ogólny – 92%. Po oczyszczeniu ścieków azot amonowy został całkowicie usunięty natomiast stężenie azotanów wzrosło do 4,6 mgN/dm3.
The aim of the research was to determine the COD fraction thereof in sewage and their changes in the effluent after further treatment processes. The study was conducted in a sewage treatment plant in Bialystok (RLM> 100000). In sewage the highest concentrations occurred in the suspension of the organic fractions slowly biodegradable XS (303.7 mg O2/l) and dissolved organic compounds readily biodegradable SS (263 mg O2/l). The lower amounts were irreducible fractions dissolved in sewage and suspended SI (56 mg O2/l) and XI (101.2 mg O2/l). Almost 80% of the total COD fractions were biodegradable (SS + XS). In the treated wastewater soluble fraction SI-biodegradable (56 mg O2/l) occurred in the highest concentration. The flow of wastewater by components of sewage treatment plant resulted the complete removal of biologically degradable fraction of dissolved SS. More than 94.5% of the total COD in waste water purified fractions were biologically decomposable (SI + XI). Moreover, based on the analysis of studies the following soil removal was found: BOD5 – 99.4%, COD – 92.9%, total nitrogen – 93.4%, total phosphorus – 92%. After waste water treatment, ammonia nitrogen was completely removed while the nitrate concentration increased to 4.6 mg N/dm3.
Źródło:
Inżynieria Ekologiczna; 2015, 45; 21-26
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza przemian materii organicznej podczas beztlenowego oczyszczania ścieków z produkcji tłuszczy jadalnych
Analysis of organic matter transformations during wastewater anaerobic treatment from production of edible fats
Autorzy:
Przywara, L.
Powiązania:
https://bibliotekanauki.pl/articles/401410.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ścieki z produkcji tłuszczów jadalnych
frakcje ChZT
substancje organiczne biodegradowalne
edible fats and oils wastewater
COD fractions
organic biodegradable matter
Opis:
W artykule analizowano przemiany materii organicznej podczas beztlenowego oczyszczania ścieków z produkcji olejów i tłuszczów pochodzenia roślinnego. W artykule opisano charakterystykę zanieczyszczeń organicznych, uwzględniającą ich podział na związki biodegradowalne oraz nie podatne na biologiczny rozkład. W celu dokonania oznaczeń fizykochemicznych zastały pobrane próbki ścieków nieoczyszczonych (przemysłowych) oraz ścieków oczyszczonych. Metodyka oznaczeń frakcji ChZT została opracowana na podstawie wytycznych ATV-131. Efektem beztlenowego oczyszczania ścieków tłuszczowych było obniżenie udziału substancji biodegradowalnych z 64,1% do 44,2% i wzrost udziału związków niebiodegradowlnych z 35,9% do 55,8%.
In this paper, transformations of organic matter during anaerobic treatment of wastewater from the production of edible fats were analyzed. The paper describes a method for characterization of organic pollutants, taking into account their division into biodegradable compounds and not susceptible to biological degradation. In order to make physicochemical determinations, the following types of wastewater samples were collected: non-treated and treated. Methodology for COD fractions determination was developed on the basis of the guidelines ATV-131. The effect of anaerobic treatment of wastewater from production of edible fats was to decrease the proportion of biodegradable compounds from 64.1% to 44.2% and increase the proportion of non-biodegradable compounds from 35.9% to 55.8%.
Źródło:
Inżynieria Ekologiczna; 2015, 41; 142-147
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of Chemical Oxygen Demand Fractions of Municipal Wastewater by Respirometric Method – Case Study
Wyznaczenie frakcji ChZT w ściekach komunalnych z wykorzystaniem metody respirometrycznej
Autorzy:
Szaja, A.
Aguilar, J. A.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/1818557.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
COD fractions
organic matter
wastewater plant simulation models
frakcje ChZT
materia organiczna
modele symulacyjne
Opis:
Jednym z ważniejszych problemów z punktu widzenia sterowania pracą oczyszczalni ścieków jest posiadanie kompletnych i dokładnych informacji na temat jakości ścieków. Do oceny parametrów jakościowych ścieków stosowane jest określanie udziałów frakcyjnych chemicznego zapotrzebowania na tlen (ChZT) pod względem właściwości fizycznych oraz podatności na biodegradację. Informacja na temat udziałów frakcyjnych ChZT może być wykorzystywana w modelowaniu pracy systemów oczyszczania ścieków jak również modelowania procesów transportu i biodegradacji zanieczyszczeń w systemach kanalizacyjnych. Opracowanie prezentuje wyniki badań udziałów frakcyjnych ścieków dopływających do miejskiej oczyszczalni ścieków w Maladze (Hiszpania). Ścieki surowe dopływały do kolektora zbiorczego z różnych dzielnic miasta kolektorami oznaczonymi jako A, B oraz C, natomiast kolektorem D doprowadzane były wody z gospodarki osadowej, zawracane na początek procesu technologicznego oczyszczalni. Do wyznaczenia udziałów frakcyjnych ChZT w analizowanych próbkach ścieków wykorzystane zostały metody respirometryczne. W przypadku ścieków surowych największy udział w całkowitym ChZT miała frakcja biodegradowalna, 47–57% przypadało na frakcje szybko ulegające biodegradacji, natomiast 13 do 16% na frakcje wolno ulegające biodegradacji. Odcieki z urządzeń gospodarki osadowej charakteryzowały się znacznym udziałem frakcji nieulegających biodegradacji, przy czym 69% przypadało na frakcje w postaci zawiesiny, natomiast 6,7% w postaci rozpuszczonej.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 289-299
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza podatności na rozkład biologiczny odcieków składowiskowych oczyszczanych w wielostopniowym systemie hydrofilowym
Analysis of biodegradibility of landfill leachate treated in a multi-stage constructed wetland
Autorzy:
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297668.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
oczyszczalnie hydrofilowe
frakcje ChZT
podatność na biodegradację
materia organiczna
skuteczność usuwania
constructed wetlands
COD fractions
biodegradability
organic matter
removal efficiency
Opis:
Przedstawiono wyniki badań, których celem była analiza biodegradowalności odcieków składowiskowych oczyszczanych w wielostopniowym systemie hydrofitowym. Zastosowano układ technologiczny składający się z dwóch złóż o przepływie podpowierzchniowym pionowym oraz złoża o przepływie podpowierzchniowym poziomym. Podatność odcieków składowiskowych na rozkład biologiczny oceniano przez pomiar ChZT i jego frakcjonowanie, w odciekach po kolejnych etapach oczyszczania. Badania prowadzono w dwóch etapach: w pierwszym złoża zasilano odciekami składowiskowymi, natomiast w etapie drugim mieszaniną odcieków składowiskowych i ścieków bytowych. W obu etapach stwierdzono bardzo wysoki udział frakcji nierozkładalnych (Si oraz Xi) w odciekach doprowadzanych do pierwszego złoża, wynoszący 72,8% dla odcieków składowiskowych oraz 53,6% dla odcieków zmieszanych ze ściekami. W obu etapach badań bardzo niskie były wartości frakcji rozpuszczonej rozkładalnej na drodze biologicznej (Ss). Wartości frakcji rozkładalnych na drodze biologicznej obniżały się po kolejnych złożach. Odcieki odpływające z oczyszczalni hydrofitowej zawierały niemal wyłącznie substancję organiczną w formie niepodatnej na rozkład biologiczny. Stwierdzono wpływ jakości substancji organicznej (zawartości frakcji inertnych oraz podatnych na rozkład biologiczny oraz ilorazu BZT5/ChZT) na efektywność usuwania ChZT. Usuwanie ChZT przebiegało z wyższą skutecznością w okresie, kiedy odcieki zawierały dodatek ścieków bytowych. Potwierdza to, że dodatek labilnej materii organicznej korzystnie wpływa na efektywność oczyszczania odcieków w procesach biologicznych.
In the article the results of analyses of biodegradability of landfill leachate treated in a multi-stage constructed wetland are presented. The treatment system consisted of two subsurface vertical flow beds followed by a subsurface horizontal flow bed. The biodegradability of leachate was evaluated by measurement of COD and COD fractions after subsequent stages of treatment. The research was conducted at two stages: in the first stage the beds were fed with pure leachate, while in the second stage the leachate was mixed with sanitary sewage. At both stages very high share of inert (not biodegradable) fractions (Si and Xi) was measured in the raw leachate discharged to the first bed (72.8% in the first stage and 53.6% in the second stage). Also at both stages the share of soluble biodegradable fraction Ss was very low. The shares of Ss fraction decreased after subsequent beds. At the outflow the leachate contained organic matter only in the inert form, resistant to biological treatment. It was found out that organic matter quality (the content of inert fractions and BOD/COD ratio) influenced the COD removal efficiency. The COD was more effectively removed in the second research stage which confirms that addition of sanitary sewage improves treatment efficiency of landfill leachate.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 4; 703-712
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
COD fractions in raw and mechanically treated wastewater
Frakcje ChZT w ściekach surowych i mechanicznie oczyszczonych
Autorzy:
Płuciennik-Koropczuk, E.
Sadecka, Z.
Myszograj, S.
Powiązania:
https://bibliotekanauki.pl/articles/396162.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
raw wastewater
COD fractions
ASM models
mechanical treatment
substances biodegradable
organic substances
ścieki surowe
Frakcje ChZT
modele ASM
oczyszczanie mechaniczne
substancje biodegradowalne
substancje organiczne
Opis:
The paper presents results of studies concerning the designation of COD fraction in the raw and mechanically treated wastewater in different year seasons. The research object was a mechanical-biological wastewater treatment plant with the output of >40 000 P.E., located in western Poland. The results of COD fraction in the raw wastewater were compared with data received in the ASM models. Methodology for determining the COD fraction was based on the guidelines ATV - A 131. During the research following fractions were determined: particulate slowly biodegradable substrates (Xs), soluble readily biodegradable substrates (Ss), inert particulate organic material (Xr) and inert soluble organic material (Sr). Soluble and particulate components were differentiated by filtration through 0.45μm membrane filters. The percentage of each fraction in total COD determined on the real concentration in raw wastewater are different from data reported in the literature.
W artykule przedstawiono wyniki badań dotyczące frakcji ChZT w ściekach surowych i mechanicznie oczyszczonych w piaskowniku. Badania prowadzono w mechaniczno-biologicznej oczyszczalni ścieków o wielkości>40 000 RLM, zlokalizowanej w zachodniej Polsce. Próbki do badań pobierano w różnych porach roku. Metodyka wyznaczania frakcji ChZT została opracowana w oparciu o wytyczne ATV-131. Podczas badań określono następujące frakcje: substancje organiczne w zawiesinie, biologicznie wolno rozkładalne (Xs), rozpuszczone substancje organiczne, biologicznie łatwo rozkładalne, (Ss), substancje organiczne w zawiesinie, biologicznie trudno rozkładalne (Xr) i rozpuszczone substancje organiczne, biologicznie nierozkładalne (Sr). Rozdziału frakcji rozpuszczonych i w zawiesinie dokonano przez filtrację próbek ścieków przez filtry membranowe o wielkości porów 0,45 μm. Wyniki badań wykazały, że zarówno w ściekach surowych jak i oczyszczonych mechanicznie udział frakcji biodegradowalnych wynosił ok. 80% całkowitego ChZT. Oczyszczanie ścieków w piaskowniku spowodowało obniżenie stężenia zanieczyszczeń organicznych o ok. 30% oraz wpływało na zmiany w udziale frakcji rozpuszczonych i w zawiesinie. Wartości procentowego udziału frakcji XS i XI w ściekach po piaskowniku zmalały, podczas gdy wartości procentowego udziału frakcji Ss i Sr wzrosły, w stosunku do ich udziału w ściekach surowych. Udział procentowy frakcji ChZT w ściekach surowych wyznaczony w badaniach różni się od danych zawartych w modelach ASM1 i ASM 2.
Źródło:
Civil and Environmental Engineering Reports; 2013, 11; 101-113
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania podatności ścieków na rozkład biologiczny na przykładzie oczyszczalni pracującej w technologii sekwencyjno-przepływowej
The results of studies of wastewater susceptibility on biological decomposition on an example of waste water treatment plant operated in the sequential-flow technology
Autorzy:
Zdebik, D.
Głodniok, M.
Powiązania:
https://bibliotekanauki.pl/articles/372491.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
frakcje ChZT
technologia sekwencyjna
technologia przepływowa
COD fractions
sequential technology
flow technology
Opis:
W artykule opisano wyniki badań mających na celu określenie udziału frakcji ChZT w ściekach surowych, po oczyszczeniu mechanicznym oraz w ściekach oczyszczonych. Całkowite ChZT było analizowane w podziale na frakcję rozpuszczoną związków organicznych łatwo przyswajalnych, rozpuszczonych związków organicznych nierozkładalnych, zawiesin organicznych wolno rozkładalnych oraz zawiesin organicznych biologicznie nierozkładalnych. Omówiono zmiany udziału poszczególnych frakcji ChZT w ciągu doby. Przeprowadzone badania wykazały, że w części mechanicznej następuje duże zmniejszenie zawiesin organicznych wolno rozkładalnej frakcji ChZT, co ma wpływ na biologiczne procesy oczyszczania ścieków ze związków biogennych.
In this paper were described the results of research aimed at identifying the contribution fraction of COD in raw wastewater, after the mechanical treatment and in treated sewage. The total COD was analyzed by the fraction of dissolved organic compounds easily absorbed, persistent dissolved organic compounds, slowly degradable organic suspended solids and biologically non-degradable organic suspensions. Changes in the share of individual fractions of COD per day were discussed. The research indicated that in the mechanical part of WWTP provides a large reduction of organic suspensions - slowly biodegradable COD fraction, which affects the biological processes of reduction of biogenic compounds in wastewater.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 141 (21); 54-65
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies