Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "BOD" wg kryterium: Temat


Wyświetlanie 1-45 z 45
Tytuł:
Effectiveness and Adaptability of Water Hyacinth (Eichornia Crassipes) Mart. Solm in its Role in Reducing COD and BOD Levels in Petroleum Liquid Waste
Autorzy:
Hardestyariki, Dwi
Fitria, Syarifa
Powiązania:
https://bibliotekanauki.pl/articles/2086418.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD
BOD
phytoremediation
Opis:
This study aimed to determine the effectiveness and ability of water hyacinth (Eichornia crassipes Mart. Solm) in reducing the COD and BOD levels in petroleum liquid waste. Petroleum liquid waste is one type of waste that pollutes the environment if it is not treated first. In this study, the biological treatment techniques were carried out using the phytoremediation techniques. Phytoremediation is an effort to reduce and improve the quality of waste by using plant agents so that the levels of pollutants contained in the waste can be reduced. The phytoremediation techniques are carried out using a simple bioreactor with various concentrations of petroleum liquid waste, namely control (0% waste), 10% waste, 20% waste, and 30% waste. The results of this study showed that the water hyacinth plant was able to tolerate liquid petroleum waste, which was indicated by the water hyacinth plant being able to survive up to a concentration of 30% for approximately 2 months. On the basis of the measurement of BOD and COD of petroleum liquid waste before phytoremediation was carried out, it was 20 mg/l and 10.04 mg/l, respectively. At 10% effluent concentration, the BOD and COD values decreased to 4.11 mg/l and 14.7 mg/l, respectively. At 20% effluent concentration, the BOD and COD values also showed a decrease to 3.73 mg/l and 9.14 mg/l, respectively. At 30% effluent concentration, the BOD and COD values showed a decrease to 3.73 mg/l and 1.22 mg/l, respectively. The ability of the water hyacinth plant to reduce the BOD and COD values can show its effectiveness to be used as a phytoremediation agent for petroleum waste.
Źródło:
Journal of Ecological Engineering; 2022, 23, 5; 26--29
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Advanced Oxidation Treatment of Composting Leachate of Food Solid Waste by Ozone-Hydrogen Peroxide
Autorzy:
Gliniak, Maciej
Lis, Anna
Polek, Daria
Wołosiewicz-Głąb, Marta
Powiązania:
https://bibliotekanauki.pl/articles/124275.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
BOD5
COD
oxidation
compost
leachate
Opis:
The research was conducted to investigate the efficiency and possibilities of advanced oxidation process based on ozone-hydrogen peroxide. The process was used as a post-treatment step of composting leachate utilisation. The leachate samples were collected from a typical composting plant with the aerobic biological treatment system. The samples were conditioned in a “ozone reactor” without dilution. The effectiveness of the treatment process was measured by pH values (4.0-7.0), H2O2 concentrations (0.5-4.0 g∙dm-3), ozone doses (0.5-1.5 g∙h-1) and reaction times (0-10 min). The highest removal efficiencies achieved were 85% and 92% for chemical oxygen demand (COD) and biochemical oxygen demand (BOD5), respectively. The optimum process parameters occurred at pH 5.0, 2.0 g∙dm-3 concentration of H2O2, and 0.75 g∙h-1 of ozone dose. The optimal reaction time was 3 min. The O3/ H2O2 advanced oxidation process was found to oxidize COD and BOD5 of the composting leachate. The oxidation reaction can be used as a feasible technique for composting leachate treatment.
Źródło:
Journal of Ecological Engineering; 2019, 20, 5; 203-208
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wastewater Pollutants Modeling Using Artificial Neural Networks
Autorzy:
Al Saleh, Hadeel Ali
Powiązania:
https://bibliotekanauki.pl/articles/1955438.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ANN
COD
BOD5
TSS
propagation algorithm
Opis:
In this study, the execution and assessment of the ANN approach towards the declaration of the pollution was used. The ANN-based models for prediction of Chemical and Biological Oxygen demands, (COD & BOD5) and Total Suspended Solids (TSS) concentrations in the effluent were formed using a three-layered feed forward back propagation algorithm ANN towards assessing the performance of a wastewater treatment plant (WWTP). Two types of configurations were used, MISO and MIMO. The study showed the superiority of MIMO according to the results of R and MSE, which were used as evaluation functions for the predicted models. The results also showed that the model built to predict the values of BOD5 concentrations demonstrate the best performance among the rest of the models by achieving the value of correlation coefficient up to 0.99. Among the input combinations tested in the study, the models the inputs of which did not contain BOD5 had the best performance, which demonstrates that the BOD5 has the largest influence on the values of R in the COD prediction models as well as other predicted models than TSS and other parameters; consequently, the performance of the WWTP was greatly affected. This study demonstrated the value of using artificial networks to represent the complex and non-linear relationship between raw influent and treated effluent water quality measurements.
Źródło:
Journal of Ecological Engineering; 2021, 22, 7; 35-45
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the Development of Household Wastewater Treatment Unit
Autorzy:
Ghawi, A. H.
Powiązania:
https://bibliotekanauki.pl/articles/125287.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
septic tank
bioreactor
wastewater
BOD
COD
households
Opis:
The cities of Iraq in general and the city of Al Diwaniyah in particular are characterized by the fact that the majority of households use septic tank to dispose of sewage, leading to contamination of ground and surface water and a disturbance to the environment. The objective of this study is to protect the water and soil sources from the risk of pollution, eliminate the process of perfusion and thus, reduce costs, maintain public health, as well as design and implement the proposed purification unit for domestic wastewater treatment. A domestic wastewater treatment unit has been improved to meet the standard specifications for the quality of the effluent wastewater. In this study, a compact non-electric sewage treatment unit was improved and implemented. Treatment is based on an effective modern biological purification process. Experimental verification and analysis of results were performed to demonstrate the improvement of physical and chemical parameters. The performance of the septic tanks-bioreactor gave satisfactory results. The removal efficiencies of Total Biochemical Oxygen Demand (BOD), Total Chemical Oxygen Demand (COD), NH4-N, Total Nitrogen and Total Suspended Solid (TSS) were 96.9%, 84.6%, 78.8%, 79.9% and 95.3%, respectively.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 63-71
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Medical Wastewater by Moving Bed Bioreactor System
Autorzy:
Jasem, Y. I.
Jumaha, G. F.
Ghawi, A. H.
Powiązania:
https://bibliotekanauki.pl/articles/123105.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
MBBR
BOD removal
COD removal
SS removal
Opis:
The hospital wastewater is considered as a complex mixture, populated with microbial and a variety of toxic substances. The performance of EEC USA moving bed biofilm reactor (MBBR) with polyethylene media as biofilm support carrier, packaged wastewater treatment plant with a capacity of 250 m(3)/day was evaluated for treating the wastewater from Al-Batul hospital of Baquba city in Iraq in terms of the organic matter and suspended solid removal, along with nitrification and microbial growth for medical wastewater. The test results showed that the average removal efficiency of biochemical oxygen demand (BOD5), chemical oxygen demand (COD), and total suspended solid (TSS) were 79.5%, 74.5%, and 78%, respectively. The system offers good nitrification with the efficiency of 79%. The system shows a weak formation of biomass on carriers, only 1.93 g TSS/m(2) of media, corresponding to 32% of the suspended biomass in the reactor.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 135-140
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wastewater treatment technologies
Autorzy:
Wilas, Janusz
Draszawka-Bołzan, Beata
Daniszewski, Piotr
Cyraniak, Emil
Powiązania:
https://bibliotekanauki.pl/articles/1119310.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
BOD
COD
TSS
small wastewater treatment plants
technology selection
Opis:
The article presents an application of multi-criteria analysis for selection of the best treatment technology and the best technical solution to the running of a large and a small wastewater treatment plant. The calculations performed for two plant capacities and for various effluent standards are based on a compromise programming method. The effluent standards considered for the smaller plant are only BOD5, COD and TSS, while for the larger plant also nitrogen and phosphorus. For each plant’s capacity, three different treatment technologies are analyzed. The analyzed technologies included biofilters, continuous and cyclic activated sludge, rotating biological contactors and natural treatment methods. The selection of the best technology is done with a define set of sustainability criteria that can be easily modified and adjusted to specific local conditions. The proposed method can be used for selection of the best treatment technology and the most appropriate technical solution from a sustainability standpoint, at the stage of wastewater system planning and designing, as well as for evaluation of already operating plants.
Źródło:
World News of Natural Sciences; 2016, 4; 33-43
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of removing organic pollutants from wastewater in a household wastewater treatment plant with a hybrid reactor
Autorzy:
Marzec, M.
Powiązania:
https://bibliotekanauki.pl/articles/124693.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
hybrid reactor
BOD5
COD
TSS
Opis:
The purpose of the study is to evaluate the efficiency of removing organic pollutants from wastewater in a household wastewater treatment plant with a hybrid reactor. The efficiency of the plant was analyzed in terms of decreasing BOD5, COD and the content of total suspended solids in differentiated technological conditions. The variable parameter was the length of the reactor aeration phase and the dwell phase. Six different aeration variants were analyzed. The efficiency of a wastewater treatment plant with a hybrid reactor in terms of reducing BOD5 oscillated from 81 to 90%, COD – 64–84%, whereas total suspended solids – 66–89% which, as a rule, was not sufficient to achieve standard levels. The best results were achieved for the following variants: 2h aeration – 2h dwell and 1h aeration – 0.5h dwell. Lower efficiency of the plant could have been attributed to operational problems, mainly failures of the plant control system and uneven conditions such as air temperature, volume and composition of wastewater received in the plant.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 240-246
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the removal of BOD5, COD and suspended solids in subsurface flow constructed wetland in Latvia
Analiza usuwania BZT5, ChZT i zawiesiny ogólnej w sztucznym ekosystemie mokradłowym o poziomym przepływie podpowierzchniowym, zlokalizowanym na Łotwie
Autorzy:
Grinberga, L.
Grabuza, D.
Grinfelde, I.
Lauva, D.
Celms, A.
Sas, W.
Głuchowski, A.
Dzięcioł, J.
Powiązania:
https://bibliotekanauki.pl/articles/2084106.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
constructed wetlands
subsurface flow
BOD
COD
suspended solids
Opis:
This study aims to evaluate the performance of subsurface flow constructed wetland in Latvia which was established to receive storm water from surface runoff from a farmjard in agricultural area. As a part of this study, subsurface horizontal flow wetlands was monitored, in order to evaluate the changes in the efficiency of treatment depending on biological factors. The efficiency of horizontal subsurface flow constructed wetland was evaluated by comparing the concentration of total suspended solids (TSS), biochemical oxygen demand (BOD5) and chemical oxygen (COD) at inlet and outlet of the wetland depending on temperature and pH. Since June 2014, water quality monitoring in a research site in the farm “Mezaciruli”, Zaļenieku parish, Jelgava region has been carried out to treat the point source agricultural runoff from the impermeable pavements. The analysis of the data obtained in the monitoring allows to draw conclusions about the influence of certain factors in the subsurface flow constructed wetlands under the climate and environmental conditions in Latvia.
Źródło:
Acta Scientiarum Polonorum. Architectura; 2021, 20, 4; 21-28
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Membrane Bioreactor for Greywater Treatment
Autorzy:
Fikri, Elanda
Zulkarnain, Oryza Filial
Azizah, R.
Latif, Mohd Talib
Firmansyah, Yura Witsqa
Powiązania:
https://bibliotekanauki.pl/articles/24201755.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
membrane bioreactor
wastewater
greywater
BOD
COD
total coliform
Opis:
Urban planning management should consider wastewater as a challenge. Wastewater, in this case, grey water, is full of dangerous contaminants and, at specific concentrations, can turn into a substance that affects the environment. The effluent of the released waste must therefore be managed to ensure that it complies with the government’s quality standard criteria. The membrane bioreactor (MBR) technology process produced waste effluents with low concentrations of biological oxygen demand (BOD5), chemical oxygen demand (COD), and total organic carbon (TOC), proving its higher efficiency as a biological processing stage. Total coliforms and E. coli are not present in processed products, detergents and total suspended solid (TSS) are effectively degraded. This is made possible by the considerably lower organic load; as a result, biomass accumulation slows and mixed liquor suspended solids (MLSS), which have low value, are produced. With the assistance of continuous airflow, and without the use of chemicals or backwashing, an ultrafiltration module (UF) with a membrane cut-off size small enough to be able to create a constant permeate flux during the grey water treatment process is necessary. Although processed grey water does not pass denitrification, all parameters linked to the quality of the effluent water exceed environmental quality criteria.
Źródło:
Journal of Ecological Engineering; 2023, 24, 6; 207--213
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of green wall treatment of brewery wastewater
Autorzy:
Wolcott, S.
Martin, P.
Goldowitz, J.
Sadeghi, S.
Powiązania:
https://bibliotekanauki.pl/articles/207907.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
food waste
BOD
biological processes
odpady spożywcze
BZT
procesy biologiczne
Opis:
Green walls or living walls are architectural installations comprised of plants growing in soil filled, modular panels that are attached to interior or exterior walls. The objective of this study is to evaluate the effectiveness of using green walls to pretreat wastewater generated by small to medium sized food and beverage manufacturers. A 1.2 m high green wall was constructed using two, 610 mm×610 mm panels filled with recycled glass media and planted with Epipremnum aureum. Brewery wastewater was recirculated through the system under four experimental scenarios: media, only; media with bio-film; media with plants; and media with plants and biofilm. Reduction of BOD was at least 65% after 24 hours in all four scenarios. Removal of turbidity, BOD, and total nitrogen was similar in scenarios involving biofilm with or without plants. Green walls appear to offer a space and cost efficient method for pretreating wastewater generated by beverage and food industries.
Źródło:
Environment Protection Engineering; 2016, 42, 4; 137-149
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wód Noteci na szlaku żeglugowym Nakło, Krzyż, Santok
An Opinion on the Water Quality of the River Noteć on the Nakło, Krzyż, Santok Navigational Route
Autorzy:
Jóźwiak, Z.
Bosy, A.
Gąsiorowska, M.
Grabia, M.
Banach, A.
Majewski, Ł.
Kilar, A.
Matkowska, K.
Powiązania:
https://bibliotekanauki.pl/articles/906896.pdf
Data publikacji:
2007
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
Noteć
BZT
ChZT
OWO
Noteć River
BOD
COD
TOC
Opis:
W artykule przedstawiono wyniki badań wód Noteci, które przeprowadzono w okresie 18-30 sierpnia 2005 roku z pokładu statku szkolnego " W. Łokietek", w ramach działalności statutowej Naukowego Koła Ekologii przy AM w Szczecinie. Metodą spektrofotometrii UV (długość fal 205-320 nm) określono następujące wskaźniki: ogólny węgiel organiczny, chemiczne i biologiczne zapotrzebowanie tlenu, zawartość azotanów, zawiesiny ogólne oraz substancje powierzchniowo czynne.
The article presents the results of research on the cleanness of the River Noteć. The analysis was were executed in the period 18-30 August 2005 by students from the Scientific Circle of Ecology, Maritime University, in time of student training period on the ship "Wł. Łokietek". Using the method of spectrophotometer UV (205-320 nm length), the following indicators were qualifield: the total organic carbon, chemical oxygen demand, biological oxygen demand, content of nitrates, total suspended solids and surfactants.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2007, 12 (84); 47-58
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of the physical and chemical parameters of water in pools of port in Swinoujscie in 2009
Autorzy:
Cyraniak, E.
Daniszewski, P.
Draszawka-Bołzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/411959.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
swimming pools port
natural water quality
pH
BOD5
COD-Cr
Opis:
The aim of this work was to be traced during the summer and autumn of 2009 the level and dynamics of changes in the waters of the port the port Swinoujscie general parameters pools water quality. In the work of the General indicators of water temperature, were numbered: pH, BOD5, CODCr, Cl-. All the markings and the calculation was performed according to the methods recommended by Polish Standards, applying analytical procedures described in. by Dojlido, Elbanowska, Hermanowicz. Port of Swinoujscie is a sea port located on the Gulf of Pomorska, on the southern coast of the Baltic Sea, on the islands of Usedom and Wolin. The Port is located at the Swina, In Swinoujscie, West Pomeranian Voivodeship. The port can be placed on ships with a maximum length of 42.0 m and width 260,0 m, draught 12.8 m. The tides in the Harbor, but the water level fluctuations are possible with sudden currents entering and outgoing, which depending on the direction of prevailing winds and reaching speeds of up to 1.5 knots. At the entrance to the port at the West breakwater, It is Western. The primary function of the port of Swinoujscie is the transshipment of cereals, ores, oil, paper, cellulose, general cargo, coal, iron. Trying to test water were collected by PN/C-04632.03 with a depth of about. 2 m below the water surface. The temperature at the place of sampling were numbered, pH. Collected water samples were fixed in accordance with the recommendations in the Polish Standard-PN/C-04632.04. Other indicators for the quality of the Walters have been tagged within 24 hours from the moment of download attempts. The quality objectives was evaluated according to the criteria recommended to evaluate inland surface waters referred to In regulation of the Minister of the environment of 11 February 2004 on the classification for the prezent status of surface water and groundwater, how to conduct monitoring and how to interpret the results and presentation of these waters. Due to the exposure of the docks the port Swinoujscie on the pollution associated with cross-what are the cereals, ores, oil, cellulose, carbon, iron, general research evaluation of the water quality of these pools, you can assess the status of water in order to keep these waters.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 1; 78-84
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of surface water pollutant models of estuaries and coastal zone of Quang Ninh – Hai Phong using Spot-5 images
Ocena modeli zanieczyszczeń wód powierzchniowych w ujściach rzek i strefy przybrzeżnej Quang Ninh – Hai Phong przy wykorzystaniu obrazów Spot-5
Autorzy:
Ke, L. C.
Van Trang, H. T.
Liem, V. H.
Tuong, T. N.
Duyen, P. T.
Powiązania:
https://bibliotekanauki.pl/articles/145410.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
estuarine
pollution
BOD
COD
TSS
zanieczyszczenia
wody powierzchniowe
metoda teledetekcyjna
Opis:
The coastal zone and estuaries of Quang Ninh and Hai Phong have great potential not only for economic development but also for protection and conservation of biodiversity and ecosystem. Nowadays, due to industrial, agricultural and anthropogenic activities signs of water pollution in the region have been found. The level of surface water pollution can be determined by traditional methods through observatory stations. However, a traditional approach to determine water contamination is discontinuous, and thereby makes pollution assessment of the entire estuary very difficult. Nowadays, remote sensing technology has been developed and widely applied in many fields, for instance, in monitoring water environments. Remote sensing data combined with information from in-situ observations allow for extraction of polluted components in water and accurate measurements of pollution level in the large regions ensuring objectivity. According to results obtained from Spot-5 imagery of Quang Ninh and Hai Phong, the extracted pollution components, like BOD, COD and TSS can be determined with the root mean square error, the absolute mean error and the absolute mean percentage error (%): ±4.37 (mg/l) 3.86 (mg/l), 27%; ±55.32 (mg/l), 48.30 (mg/l), 14%; and ±32.90 (mg/l), 23.38 (mg/l), 28%; respectively. Obtained outcomes guarantee objectivity in assessing water contaminant levels in the investigated regions and show the advantages of remote sensing applications in Resource and Environmental Monitoring in relation to Water – Air – Land.
Strefa przybrzeżna i ujścia rzek w Quang Ninh – Hai Phong ma potencjał do rozwoju gospodarczego i ochrony różnorodności biologicznej i ekosystemu. Ostatnio stwierdzono tam wiele oznak zanieczyszczenia wody. Poziom zanieczyszczenia wód powierzchniowych może być określany na stacjach obserwacyjnych metodami tradycyjnymi, jednak znacznie szybsze i dokładniejsze jest wykorzystanie metod teledetekcyjnych. Analiza obrazów Spot-5 w Quang Ninh – Hai Phong umożliwiła stwierdzenie obecności różnych zanieczyszczeń, w tym BOD, COD i TSS ze średnim błędem kwadratowym, średnim błędem absolutnym i średnim błędem względnym odpowiednio: ± 4.37 (mg/l), 3.86 (mg/l), 27%; ± 55.32 (mg/l), 48.30 (mg/l), 14%; ± 32.90 (mg/l), 23.38 (mg/l), 28%. Otrzymane wyniki gwarantują obiektywizm przy ocenie poziomu zanieczyszczeń w badanych regionach i pokazują korzyści zastosowań teledetekcji w monitoringu zasobów i środowiska w odniesieniu do wody – powietrza – terenu.
Źródło:
Geodesy and Cartography; 2015, 64, 1; 29-42
2080-6736
2300-2581
Pojawia się w:
Geodesy and Cartography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary Studies of the Water Quality in the Reservoir Wielkopolska at Different Times of Operation on the Basis of Selected Indicators
Autorzy:
Walczak, Natalia
Walczak, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/1839125.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water quality
reservoir
nitrogen
phosphorus
BOD5
total suspended solids
Opis:
For the purposes of research and this resultant publication, the water quality was tested in three reservoirs differing in operating times. It was assumed that the study period covering autumn, spring and early summer was the period with the most visible changes in the concentrations of pollutants. The samples taken from the reservoirs were analysed by determining biological oxygen demand (BOD5), ammonia concentration (NH4), phosphate concentration (PO4) and total suspended solids. The use of indicators allowed for assessing the quality of water in these reservoirs and comparing it in terms of different periods of their operation. It was also observed that the water flowing into the Roszków and Jeżewo reservoirs (two oldest reservoirs) was of worse quality than the outgoing water. In the case of the newest reservoir, the water quality at the outflow deteriorated in relation to all indicators.
Źródło:
Journal of Ecological Engineering; 2021, 22, 2; 77-85
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena podatności na biodegradację oraz toksyczność wybranych roślinnych związków fenolowych i ich pochodnych
Evaluation of biodegradability and toxicity of selected plant phenolic compounds and their derivatives
Autorzy:
Samsonowicz, M.
Kalinowska, M.
Matejczyk, M.
Rafało, M.
Lewandowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/271037.pdf
Data publikacji:
2012
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
pochodne kwasu cynamonowego
toksyczność
biodegradacja
BZT
biodegradation
cinnamic acid derivatives
toxicity
BOD
Opis:
Kwasy cynamonowy, p-kumarowy oraz kawowy to występujące w roślinach związki o szeroko znanych właściwościach antyutleniających oraz antybakteryjnych. Ich sole to potencjalne nowe konserwanty, które ze względu na naturalne pochodzenie byłyby przyjazne dla człowieka i środowiska. W ramach pracy zsyntezowano sole ww. kwasów, oceniono ich skład za pomocą spektroskopii w podczerwieni (FT -IR). Zbadano toksyczność ostrą w stosunku do organizmów wskaźnikowych oraz podatność na biodegradację (stosując wskaźniki: biochemiczne zapotrzebowanie na tlen, BZT; chemiczne zapotrzebowanie na tlen (ChZT), rozpuszczony węgiel organiczny, RWO) wybranych pochodnych kwasu cynamonowego i ich soli. Zmiany stężeń związków w trakcie pomiarów oceniono za pomocą absorpcyjnej spektroskopii elektronowej (UV/VIS).
Cinnamic, p-coumaric and caffeic acids, naturally present in many plants, are commonly known because of their antioxidant and antimicrobial activities. Their salts are potentially new preservatives, which because of their natural origin, would be safe for human and environment. In the frame of this work selected salts of these acids were synthetized and their constitution was estimated by the use of infrared spectroscopy. The acute toxicity toward indicator organisms and susceptibility to biodegrada- tion (by means of: biochemical oxygen demand, BOD; dissolved organic carbon, DOC) of cinnamic acid derivatives and their salts were studied. Changes in the concentration of individual compounds were determined by UV/VIS spectroscopy.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2012, 17, 2; 75-82
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of the physical and chemical parameters of water in pools of port in Szczecin in 2009
Autorzy:
Cyraniak, E.
Daniszewski, P.
Draszawka-Bołzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/411965.pdf
Data publikacji:
2013
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
swimming pools port
natural water quality
pH
BOD5
COD-Cr
Opis:
The aim of this work was to be traced during the summer and autumn of 2009 the level and dynamics of changes in the waters of the Port of Szczecin General docks parameters water quality. In the work of the General indicators of water temperature, were numbered: pH, BOD5, COD-Cr, Cl-. All the markings and the calculation was performed according to the methods recommended by Polish Standards, applying analytical procedures described in by Dojlido, Elbanowska, Hermanowicz. Port of Szczecin is located on the Oder river and its right shoulder Regalicy. Is located in the western part of the port of Szczecin, in the northern part of the Valley of the lower Oder river on May. The port consists of water bodies which are branches of the Oder river and the channels: Mielenski, Grabowski, Dunczyca Channel Figh, Wroclaw, Parnica, Channel Channel Debicki and Lake Dabie. Trying is water were collected by PN/C-04632.03 with a depth of about. 2 m below the water surface. The temperature at the place of sampling were numbered, pH. Collected water samples were fixed In accordance with the recommendations in the Polish Standard-PN/C-04632.04. Other indicators for the quality of the waters have been tagged within 24 hours from the moment of download attempts. The quality objectives was evaluated according to the criteria recommended to evaluate inland surface waters referred to in regulation of the Minister of the environment of 11 February 2004 on the classification for the present status of surface water and groundwater, how to conduct monitoring and how to interpret the results and presentation of these waters. Due to the exposure of the docks the port Szczecin on the pollution associated with cross-what are the cereals, ores, oil, cellulose, carbon, iron, general research evaluation of the water quality of these pools, you can assess the status of water In order to keep these waters.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2013, 1; 70-77
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of QUAL2K Model for Simulating Water Quality in Hilla River, Iraq
Autorzy:
Al-Dalimy, Shahad Z.
Al-Zubaidi, Hussein A. M.
Powiązania:
https://bibliotekanauki.pl/articles/24202900.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water quality
QUAL2K
management modeling
Hilla River
BOD
DO
Opis:
The quality of the water in Iraq’s Hilla River has been severely degraded as a result of human activities and industrial development. The QUAL2K model, a widely used one-dimensional water quality model, was used to simulate the river’s water quality parameter of CBODu and DO utilizing river and point-source flows rate as well as quality of water metrics observed along the river. Despite a severe lack of data in the research region, the QUAL2K model was determined to be an adequate instrument for the evaluation of quality of water. Simulated results of DO, BOD5, and temperature for the period (October 2022) showed the robustness of the model. Results showed that the two parameters (CBOD and DO) ranged between (9.5 and 10.65) mg/L and between (1.425 and 3.075) mg/L, respectively. Based on statistics, good agreement was found between the model predictions and field data. Thus, using QUAL2K model is an effective tool to manage the river water quality.
Źródło:
Journal of Ecological Engineering; 2023, 24, 6; 272--280
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność usuwania substancji organicznej i fosforu ze ścieków w oczyszczalniach hydrofitowych
The efficiency of organic matter and phosphorus removal from sewage in constructed wetlands
Autorzy:
Sekułowicz, J.
Karczmarczyk, A.
Mosiej, J.
Powiązania:
https://bibliotekanauki.pl/articles/338049.pdf
Data publikacji:
2006
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
fosfor
oczyszczanie ścieków
złoże trzcinowe
BOD5
phosphorus
reed bed
wastewater treatment
Opis:
Układ technologiczny analizowanej oczyszczalni to stanowiące część biologiczną złoże gruntowo-trzcinowe z podpowierzchniowym poziomym przepływem ścieków oraz staw, poprzedzone osadnikiem. W latach 2004-2005, czyli w szóstym i siódmym roku eksploatacji oczyszczalni, pobierano próby ścieków z poszczególnych elementów systemu oraz próby ścieków odpływających z obiektu, w których określano zawartość substancji organicznej (wyrażonej wskaźnikiem BZT5 ) oraz fosforu. Oceny skuteczności usuwania zanieczyszczeń dokonano w odniesieniu do złoża i całego systemu oczyszczania ścieków. W pracy wykorzystano również wyniki analiz z wcześniejszych lat (od drugiego do piątego roku eksploatacji obiektu), udostępnione przez administratora oczyszczalni. W wyniku obserwacji stwierdzono, że skuteczność usuwania substancji organicznej w złożu w 2004 r. wynosiła od 77,5 do 85,5%, a w pierwszej połowie 2005 r. - od 52,9 do 90,3%, zaś w przypadku fosforu obserwowano zarówno zmniejszanie, jak i zwiększanie się stężenia w ściekach. Skuteczność usuwania substancji organicznej w całym systemie w 2004 r. wynosiła od 85,7 do 97,7% (BZT5 = 10-40 mg O2·dm-³-³ w ściekach oczyszczonych), a w pierwszej połowie 2005 r. od 77,4 do 91,4% (BZT5 = 20-70 mg O2·dm-³ w ściekach oczyszczonych). Stężenie fosforu w ściekach oczyszczonych w całym systemie w 2004 r. wynosiło 0,03-0,7 mg·dm-³ , a w pierwszej połowie 2005 r. 0,1-9,8 mg·dm-³ . Na podstawie uzyskanych wyników podjęto również próbę oszacowania tendencji zmian skuteczności usuwania zanieczyszczeń w złożu gruntowo-trzcinowym i całym systemie na podstawie wybranych wskaźników.
Biological part of wetland consists of vegetated gravel bed with horizontal subsurface flow and pond, which are preceded by mechanical treatment in sedimentation tank. In the years 2004-2005 (the sixth and the seventh year of system operation) the sewage samples at different stages of treatment and from the outlet were taken for BOD5 and phosphorus analysis. The treatment efficiency assess-ment was made both for gravel bed and for the whole system. Also the results of previous analysis available form administrator, covering the period from second to fifth year of system operation, were included in the paper. The results of system's monitoring showed that removal efficiency of biode-gradable organics (BOD5 ) in gravel bed amounted 77.5-85.5% in 2004 and 52.9-90.3% in the first half of 2005. Phosphorus concentration in sewage treated in gravel bed varied: both the decrease and increase of concentration was observed. BOD5 removal efficiency in the whole constructed wetland system amounted 85.7-97.7% in 2004 (outlet BOD5 concentrations varied from 10 to 40 mg O2·dm-³ ) and from 77.4 to 91.4% in the first half of 2005 (outlet BOD5 concentrations varied from 20 to 70 mg O2·dm-³). The concentration of phosphorus in treated sewage varied from 0.03 to 0.7 mg·dm-³ in 2004 and from 0.1 to 9.8 mg·dm-³ in the first half of 2005. Trends of changes in the removal efficiency in both gravel bed and the whole system were assessed based on obtained results.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2006, 6, 2; 305-316
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność oczyszczania ścieków w gruncie piaszczystym z warstwą naturalnego klinoptylolitu
Sewage treatment efficacy of sandy soil bed with natural clinoptiolite assist layer
Autorzy:
Kalenik, M.
Powiązania:
https://bibliotekanauki.pl/articles/236326.pdf
Data publikacji:
2014
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
przydomowa oczyszczalnia ścieków
drenaż rozsączający
BZT5
azot
fosfor
BOD5
nitrogen
phosphorus
Opis:
Przeprowadzono badania modelowe oczyszczania ścieków w piaskowym złożu gruntowym z warstwą naturalnego klinoptylolitu o miąższości 0,10 m i 0,20 m. Stwierdzono, że w zakresie podstawowych wskaźników jakościowych (zawiesiny ogólne, BZT5 , ChZT, azot, fosor), ścieki oczyszczone w takich złożach spełniały polskie zalecenia dotyczące zasad wprowadzania ścieków do gruntu. Wykazano, że lepszą skutecznością oczyszczania ścieków charakteryzowało się złoże gruntowe z warstwą klinoptylolitu o miąższości 0,20 m, w porównaniu do złoża 0,10 m. Zastosowanie w piaskowym złożu gruntowym warstwy wspomagającej uformowanej z naturalnego klinoptylolitu o miąższości 0,20 m poprawiło skuteczność usuwania zawiesin ogólnych (śr. 3,5%), BZT5 (śr. 9%), ChZT (śr. 11%), azotu ogólnego (śr. 8%) i fosforu ogólnego (śr. 59%) w stosunku do złoża z warstwą wspomagającą 0,10 m. Badania potwierdziły, że naturalny klinoptylolit może być wykorzystywany do wspomagania usuwania związków azotu i fosforu ze ścieków z zastosowaniem drenażu rozsączającego. Bardzo dobra skuteczność usuwania zawiesin ogólnych ze ścieków w badanych złożach gruntowych może jednak prowadzić do szybkiej kolmatacji złoża pod drenażem rozsączającym. Z tego względu należy tak projektować osadniki gnilne, aby mogły zatrzymać jak najwięcej zawiesin ogólnych (np. osadniki kilkukomorowe zamiast jednokomorowych).
Model studies on sewage treatment in a sand bed with natural clinoptiolite assist layer of 0.1 and 0.2 m were carried out. It was observed that with regard to the basic quality parameters (total suspended solids, BOD5 , COD, nitrogen, phosphorus), the effluent complied with the Polish sewage discharge standards. The sandy soil bed with natural clinoptiolite assist layer of 0.20 m was demonstrated to be more effective in sewage treatment when compared to 0.10 m bed. Application of the assist layer of 0.2 m clinoptiolite in the sand bed improved removal efficacy of total suspended solids (av. 3.5%), BOD5 (av. 9%), COD (av. 11%), total nitrogen (av. 8%) and total phosphorus (av. 59%) when compared to the bed with 0.10m assist layer. Studies confirmed that natural clinoptiolite may be used to assist nitrogen and phosphorus removal from sewage via subsurface sewage disposal drains. However, very good efficacy of total suspended solid removal from sewage in the tested soil beds may lead to bed colmatation under subsurface sewage drain field. Therefore, settling tanks should be designed so that they could retain the greatest possible amount of total suspended solids (e.g. multi-chamber tanks instead of one-chamber tanks).
Źródło:
Ochrona Środowiska; 2014, 36, 3; 43-48
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradacja serwatki w bioreaktorze membranowym
Biodégradation of whey in a membrane bioreactor
Autorzy:
Lech, M.
Trusek-Hołownia, A.
Powiązania:
https://bibliotekanauki.pl/articles/2073194.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
laktoza
BZT
mikrofiltracja
współczynnik podziału strumieni
lactose
BOD
microfiltration
coefficient of stream division
Opis:
Celem pracy było opracowanie procesu biodegradacji serwatki lub permeatów serwatki w bioreaktorze membranowym. Na wylocie z bioreaktora została umieszczona membrana mikrofiltracyjna separująca komórki bakteryjne szczepu Lactobacillus rhamnosus, które pozostając w strefie reakcji zwiększały wydajność procesu. Wysoka koncentracja biomasy spowodowała, że strumień wylotowy zawierał o 73% mniej laktozy niż strumień opuszczający klasyczny bioreaktor mieszalnikowy pracujący w takich samych warunkach.
The aim of this work was the development of biodégradation process of whey or whey permeates in a membrane bioreactor. A microfiltration membrane was located in outlet stream which separated Lactobacillus rhamnosus bacteria in the bioreactor zone and thus the immobilized strain increased the process yield. The high biomass concentration caused the decrease of lactose concentration of about 73% in the outlet stream in comparison to a classical stirred bioreactor.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 3; 84--85
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of waste assimilative capacity (WAC) of rivers located within the Desaru Region, Joho
Autorzy:
Zainudin, Z.
Azmi, A. S.
Jimat, D. N.
Jamal, P.
Powiązania:
https://bibliotekanauki.pl/articles/206928.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water contamination
BOD5
water pollution
rivers
zanieczyszczenie rzek
BZT5
zanieczyszczenie wody
rzeki
Opis:
Desaru is a popular tourist destination located on the east coast of the state of Johor. The area has been identified for further development to enhance tourism. This presents a pollution risk to its surrounding watercourses. The purpose of this study was to assess the potential risk of contamination towards rivers located in the crux of the development region, namely the Terumpah, Che Minah, Semangar, Beluntu, Penawar Besar, and Mertang Besar Rivers. Water quality and hydraulic measurements were made at these rivers, with the intention of developing a numerical model. The model results showed deterioration in BOD5 and NH3-N in the Semangar River, up to 4.0 mg/dm3 and 0.34 mg/dm3, respectively. The Beluntu River experienced the highest degradation, to about 14.0 mg/dm3 of BOD5 and 0.8 mg/dm3 of NH3-N. The waste assimilative capacity (WAC) for the Matang Besar, Che Minah and Beluntu Rivers were very limited, with a class III BOD5 limit of 15, 43, and 10 kg/day, respectively, whereas the Terumpah River is not able to accept any BOD load without breaching the same threshold.
Źródło:
Environment Protection Engineering; 2015, 41, 4; 49-60
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stopnia zanieczyszczenia związkami organicznymi Kanału Gliwickiego i jego wybranych dopływów
The evaluation of contamination level of Gliwice Channel and its side streams with organic compounds
Autorzy:
Łobos-Moysa, E.
Powiązania:
https://bibliotekanauki.pl/articles/125839.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
naturalne cieki
zanieczyszczenia organiczne
ChZT
BZT5
OWO
natural watercourses
organic compounds
BOD5
COD
TOC
Opis:
Badania miały na celu określenie stopnia zanieczyszczenia różnych cieków wodnych zasilających Kanał Gliwicki na podstawie oznaczenia związków organicznych. Do badań wybrano wody powierzchniowe znajdujące się na terenie Gliwic i Zabrza: Doa (Wójtowiankę), Potok Rokitnicki, Bytomkę, Kłodnicę oraz Kanał Gliwicki. Próbki pobierano dwa razy w miesiącu w okresie zimowo-wiosenno-letnim w godzinach porannych w ciągu jednego dnia. Oznaczenie ChZT wykonano metodą dwuchromianową przy użyciu spektrofotometru NOVA 400 Merck; BZT5 metodą manometryczną, przy użyciu buteleczek Oxi Top firmy WTW, OWO na analizatorze TN-TC multi N/C firmy Analytik Jena. Suchą masę zawiesiny oznaczano metodą wagową. Uzyskane wyniki opracowano w zależności od parametrów fizykochemicznych badanych cieków (pH, stężenia zawiesiny) oraz ich charakterystyki (długości, ilości dopływów, charakteru terenów przez które płyną).
The aim of the study was to determine the level of contamination of different side streams of Gliwice Channel basing on analyses of organic compounds concentrations. Surface waters localized near two Silesian cities ie Zabrze and Gliwice were analyzed during the study ie Mao Stream (Wójtowianka) (1 sampling point), Rokitnica Stream (1 sampling point), Bytomka (1 sampling point), Kłodnica River (2 sampling points) and Gliwice Channel (1 sampling point). Water samples were collected twice a month in the winter-spring-summer period, always in the morning. COD analysis was made via dichromate method using NOVA 400 spectrophotometer by Merck. BOD5 was determined via respirometric method with Oxi Top equipment by WTW and TOC by multi N/C Analytik Jena. Physico-chemical parameters of investigated waters i.e. pH and temperature were measured using Elmetron set equipped with proper electrodes. Obtained results were elaborated according to physico-chemical parameters of investigated waters (pH, suspended solid concentration) and watercourse properties (length, number of side streams, flowing area characteristic).
Źródło:
Proceedings of ECOpole; 2013, 7, 1; 378-383
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Contamination Level of Gliwice Channel and Its Side Streams with Organic Compounds
Ocena stopnia zanieczyszczenia związkami organicznymi kanału gliwickiego i jego wybranych dopływów
Autorzy:
Łobos-Moysa, E.
Powiązania:
https://bibliotekanauki.pl/articles/388440.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
natural watercourses
organic compounds
BOD5
COD
TOC
naturalne cieki
zanieczyszczenia organiczne
ChZT
BZT5
OWO
Opis:
The aim of the study was to determine the level of contamination of different side streams of Gliwice Channel basing on analyses of organic compounds concentrations. Surface waters localized near two Silesian cities ie Zabrze and Gliwice were analyzed during the study ie Mao Stream (Wojtowianka) (1 sampling point), Rokitnica Stream (1 sampling point), Bytomka (1 sampling point), Klodnica River (2 sampling points) and Gliwice Channel (1 sampling point). Water samples were collected twice a month in the winter-spring-summer period, always in the morning. COD analysis was made via dichromate method using NOVA 400 spectrophotometer by Merck. BOD5 was determined via respirometric method with Oxi Top equipment by WTW and TOC by multi N/C Analytik Jena. Physico-chemical parameters of investigated waters ie pH and temperature were measured using Elmetron set equipped with proper electrodes. Obtained results were elaborated according to physico-chemical parameters of investigated waters (pH, suspended solid concentration) and watercourse properties (length, number of side streams, flowing area characteristic).
Badania miały na celu określenie stopnia zanieczyszczenia różnych cieków wodnych zasilających Kanał Gliwicki na podstawie oznaczenia związków organicznych. Do badań wybrano wody powierzchniowe znajdujące się na terenie Gliwic i Zabrza: Doa (Wójtowiankę), Potok Rokitnicki, Bytomkę, Kłodnicę oraz Kanał Gliwicki. Próby pobierano dwa razy w miesiącu w okresie od zimowo-wiosenno-letnim w godzinach porannych w ciągu jednego dnia. Oznaczenie ChZT wykonano metodą dwuchromianową przy użyciu spektrofotometru NOVA 400 Merck; BZT5 metodą manometryczną, przy użyciu buteleczek Oxi Top firmy WTW, OWO na analizatorze TN-TC multi N/C firmy Analytik Jena. Suchą masę zawiesiny oznaczano metodą wagową. Uzyskane wyniki opracowano w zależności od parametrów fizykochemicznych badanych cieków (pH, stężenia zawiesiny) oraz ich charakterystyki (długości, ilości dopływów, charakteru terenów przez które płyną).
Źródło:
Ecological Chemistry and Engineering. A; 2013, 20, 2; 271-278
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy oczyszczalni ścieków w Kołaczycach
Operational efficiency of wastewater treatment plant in Kolaczyce
Autorzy:
Chmielowski, K.
Młyńska, A.
Młyński, D.
Powiązania:
https://bibliotekanauki.pl/articles/400312.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oczyszczalnia ścieków
BZT5
ChZTCr
zawiesina ogólna
wastewater treatment plant
BOD5
CODCr
total suspended solids
Opis:
W artykule dokonano analizy efektywności pracy oczyszczalni ścieków w Kołaczycach na podstawie wyników badań fizykochemicznych ścieków surowych oraz ścieków oczyszczonych w latach 2010 – 2014. Przeanalizowano zmiany wartości trzech wskaźników zanieczyszczeń – BZT5, ChZTCr i zawiesiny ogólnej. Wyniki badań wskazują na to, iż oczyszczalnia funkcjonuje w sposób prawidłowy. Średnia wartość BZT5 w ściekach oczyszczonych wyniosła 10,9 mg O2 dm-3, ChZTCr – 71,0 mg O2 dm-3, zawiesiny ogólnej – 15,0 mgdm-3, a zatem wielkości te były mniejsze od dopuszczalnych wartości w ściekach odprowadzanych do odbiornika, które reguluje Rozporządzenie Ministra Środowiska z 2014 roku. O zadowalającej efektywności pracy obiektu świadczy również wysoka procentowa średnia redukcja każdego ze wskaźników zanieczyszczeń (dla BZT5 – 97,8%, dla ChZTCr – 93,7%, dla zawiesiny ogólnej – 97,6%), a także wartości współczynników niezawodności oczyszczalni (WNBZT5= 0,44, WNChZTCr= 0,57, WNzaw.og.= 0,43).
In the article the analysis of operational efficiency Wastewater Treatment Plant in Kolaczyce was performed based on the physico-chemical research results of raw sewage and treated sewage between 2010 and 2014. The analysis of values changing of three pollutants indicators – BOD5, CODCr and total suspended solids was performed. Research results indicate that treatment plant works properly. Average value of BOD5 in treated sewage was 10.9 mg O2 dm-3, CODCr – 71.0 mg O2 dm-3, total suspended solids – 15.0 mg dm-3 so these values were lower than permissible pollutants content in sewage discharged to the collector which is determined by the Polish Ministry of Environmental Regulation of 2014. On satisfactory operational efficiency treatment plant indicates also high percentage reduction of each pollutants indicators (for BOD5 – 97.8%, for ChZTCr – 93.7%, for total suspended solids – 97.6%) and treatment plant reliability factors (WNBZT5= 0.44, WNChZTCr= 0.57, WNzaw.og.= 0.43).
Źródło:
Inżynieria Ekologiczna; 2015, 45; 44-50
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical modelling by convection-diffusion with reaction of organic pollution in the wadi Mouillah stream, north-western Algeria
Autorzy:
Benadda, Lotfi
Djelita, Belkheir
Chiboub-Fellah, Abdelghani
Powiązania:
https://bibliotekanauki.pl/articles/2174337.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
biochemical oxygen demand
BOD5
diffusion
Hammam Boughrara dam
mathematical modelling
pollution
total phosphorus
wadi Mouillah
Opis:
This work describes the behaviour of organic pollutants along the wadi Mouillah watercourse and its main tributaries and their impacts on the Hammam Boughrara dam, located in the NW of Algeria, in the Wilaya of Tlemcen. The use of a database relating to physico-chemical, biotic and hydrological variables, covering the period from January 2006 to December 2009, contributed to the understanding of the spatiotemporal evolution of each variable. The application of a mathematical model of the diffusion by convection-dispersion with a reaction on two characteristic parameters of organic pollution, the biochemical oxygen demand (BOD5) which records values above the norm, with peaks that can reach 614%, and total phosphorus (Ptot), which the concentration is always higher with maxima reaching 53 mg∙dm-3 favouring eutrophication; this made it possible with precision to synthesise the propagation of pollutants in the liquid mass. The results obtained on the waters of Wadi Mouillah are therefore of poor quality; there is a need to set up a rigorous water quality monitoring system, with water treatment and decontamination devices to preserve the water resources. This will allow to contribute to better management of water quality in terms of combating the spread of pollution. Therefore, they can be used to support decisions in the context of sustainable development.
Źródło:
Journal of Water and Land Development; 2022, 54; 26--37
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the effluent polishing plant using a ultrafiltration membrane installed at a palm oil mill
Autorzy:
Abdul Hadi, Numan
Hawari, Yahaya
Ngatiman, Muzzammil
Jalani, Nor Faizah
Wahab, Noorshamsiana Abdul
Halim, Rohaya Mohamed
Powiązania:
https://bibliotekanauki.pl/articles/208299.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
BOD
palm oil mill
wastewater treatment
ultrafiltration membranes
BZT
olej palmowy
oczyszczanie ścieków
membrany ultrafiltracyjne
Opis:
Palm oil mills discharge raw effluent with high biochemical oxygen demand (BOD) of about 25 000 mg O2/dm3 . Conventional effluent treatment system uses ponds with a long hydraulic retention time of about 55–85 days, but the reduction of BOD is usually halted at 100–250 mg O2/dm 3. Further reduction of BOD to below 20 mg O2/dm3 to meet regulation requirement needs further advanced treatment. This study evaluates the efficiency of an effluent polishing plant installed at a palm oil mill targeting final effluent BOD below 20 mg O2/dm3. Characteristic of the incoming and treated effluent, dissolved oxygen in the aeration ponds and the effluent flow rate of the treatment plant have been determined. Due to low process throughput at the mill, the polishing plant operated at only 60% of its designed capacity. Treatment of effluent showed reduction of BOD from 39.3±5.8 to 6.1±3.8 mg O2/dm3, i.e., a reduction by 80–94%. Colour – a newly proposed regulation parameter – was reduced from 1081±69 to 845±60 ADMI, i.e., by 11–30%. This study indicates that while the treatment of effluent to reduce the BOD to below 20 O2/dm3 O2/dm3 is feasible, reduction of colour to less than 100 ADMI is not achievable.
Źródło:
Environment Protection Engineering; 2019, 45, 1; 155-170
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of processing whey waste from dairies. A review
Autorzy:
Ponist, Juraj
Dubsikova, Veronika
Schwarz, Marian
Samesova, Dagmar
Powiązania:
https://bibliotekanauki.pl/articles/2032849.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
whey
aerobic process
dairy waste
BOD
COD
serwatka
proces tlenowy
odpady z mleczarni
ChZT
BZT
Opis:
The purpose of the study was to evaluate the methods of processing whey. The valorization method is suitable for the use of cheese whey and whey permeate to produce beverages with or without microbial conversion. However, this method does not ensure microbial conversion of lactose. Therefore, the organic load will not be reduced. The main advantage of aerobic decomposition is the relatively rapid degradation of organic matter. However, the high organic load in the crude cheese whey makes aerobic decomposition unsuitable and restrictions on oxygen transport may occur. Anaerobic decomposition can be used in various areas for the treatment of waste with a high organic load. The disadvantage of anaerobic processes is a higher cost compared to aerobic treatment. The combination of individual technologies significantly reduces the hydraulic retention time of the aerobic process and improves waste treatment. At present, there is a lack of studies in this area.
Źródło:
Environment Protection Engineering; 2021, 47, 4; 67-84
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Efficiency of Nitrogen Compounds Removal in Wastewater Treatment Plant
Ocena efektywności pracy oczyszczalni ścieków o RLM 45000
Autorzy:
Suchowska-Kisielewicz, M.
Sieciechowicz, A.
Sadecka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/396351.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
nitrogen removal
BOD5/TKN ratio
wastewater temperature
usuwanie związków azotu
BZT5/TKN
temperatura ścieków
Opis:
In sewage treatment plants for removing nitrogen compounds are used biological processes of nitrification and denitrification. The parameters determining the efficiency of biological processes of nitrogen removal are organic carbon ratio (BOD5) to total Kjeldahl nitrogen (TKN), temperature and pH. The impact of these parameters on the operation of the sewage treatment plant with an RLM of 45,000 based on operational data from the period 2011-2013 has been assessed. The efficiency of removing nitrogen compounds from sewage in the analysed treatment plant depended on the temperature of sewage and the quotient BOD5/TKN. Even at the optimal ranges of BOD5/TKN ratio temperature at 10°C nitrogen concentration in the treated wastewater was about 3 times higher than the limit value, and the removal efficiency of nitrogen varied between about 30 to 60%.
W oczyszczalniach mechaniczno-biologicznych do usuwania związków azotu wykorzystuje się biologiczne procesy nitryfikacji i denitryfikacji. Usuwanie fosforu odbywa się przy wykorzystaniu metod biologicznych lub chemicznych. Sprawność procesów biologicznych wymaga odmiennych warunków środowiskowych tzn. tlenowych dla nitryfikacji, a beztlenowych dla denitryfikacji, czy tez warunków beztlenowo-tlenowych dla defosfatacji biologicznej. Parametrami decydującymi o sprawności procesów biologicznych usuwania azotu są: stosunek węgla organicznego (BZT5) do ogólnego azotu Kjeldahla (TKN), temperatura i odczyn środowiska. Wpływ tych parametrów na pracę oczyszczalni o RLM 45 000 oceniono na podstawie danych eksploatacyjnych z okresu 2011-2013. Efektywność usuwania związków azotu ze ścieków w analizowanej oczyszczalni zależała od temperatury ścieków oraz ilorazu BZT5/TKN Zmienne wartości ilorazu BZT5/TKN w zakresie od 2,7 do 8,1, wpływały na uzyskiwaną efektywność zarówno procesu nitryfikacji, jak i denitryfikacji. Nawet przy optymalnych zakresach BZT5/TKN w temperaturze poniżej 10°C stężenia azotu w ściekach oczyszczonych były nawet o około 3-krotnie wyższe od wartości dopuszczalnej, ze sprawnością usuwania azotu w zakresie od 30 do 60%.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(3); 5-16
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlations between organic pollution indicators in municipal wastewater
Korelacje pomiędzy wskaźnikami zanieczyszczeń organicznych w ściekach komunalnych
Autorzy:
Siwiec, T.
Reczek, L.
Michel, M. M.
Gut, B.
Hawer-Strojek, P.
Czajkowska, J.
Jóźwiakowski, K.
Gajewska, M.
Bugajski, P.
Powiązania:
https://bibliotekanauki.pl/articles/205468.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
BOD5
CODCr
TOC
CODMn
wastewater
municipal wastewater treatment plant
BZT5
ścieki
miejska oczyszczalnia ścieków
Opis:
The paper presents the results of a study of parameters used for determining the amount of organic pollutants in wastewater flowing into a collective wastewater treatment plant with a population equivalent of about 120 000 PE. The plant constituted part of a sewage system. Assays were performed for biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), permanganete index (CODMn) and total organic carbon (TOC). In addition, the pH of wastewater and its alkalinity were determined. Sampling of incoming wastewater and measurement of physicochemical parameters were performed once a week, in the spring. A total of 44 samples of wastewater were collected. The correlations between the individual parameters and the correlations between the ratios of these parameters were determined. It was found that it was possible to estimate, with sufficient accuracy, the values of selected parameters for determining the concentrations of organic compounds in municipal wastewater, knowing the values of other parameters in this group. Moreover, it was shown that, knowing the relationship between the analyzed parameters, one can find multiple regression equations for a given type of wastewater, which allow one to calculate the remaining relationships with a good fi t, i.e. a determination factor R2 greater than 0.6.
W pracy przedstawiono wyniki badań parametrów wykorzystywanych do oznaczania ilości zanieczyszczeń organicznych w ściekach wpływających do zbiorczej oczyszczalni ścieków o równoważnej liczbie ludności około 120 000 mieszkańców. Zakład stanowi część systemu kanalizacyjnego. Testy przeprowadzono dla biochemicznego zapotrzebowania na tlen (BZT5), chemicznego zapotrzebowania na tlen (CODCr), utlenialności (CODMn) i ogólnego węgla organicznego (TOC). Ponadto określono wartość pH ścieków i ich zasadowość. Pobieranie próbek dopływających ścieków i pomiar parametrów fizykochemicznych przeprowadzano raz w tygodniu, na wiosnę. Zebrano łącznie 44 próbki ścieków. Określono korelacje między poszczególnymi parametrami i korelacje między stosunkami tych parametrów. Stwierdzono, że możliwe było oszacowanie, z wystarczającą dokładnością, wartości wybranych parametrów do oznaczania stężeń związków organicznych w ściekach komunalnych, znając wartości innych parametrów w tej grupie. Ponadto wykazano, że znając zależność między analizowanymi parametrami, można znaleźć równania regresji wielokrotnej dla danego typu ścieków, które pozwalają obliczyć pozostałe zależności przy dobrym dopasowaniu, o współczynniku determinacji R2 większym niż 0,6.
Źródło:
Archives of Environmental Protection; 2018, 44, 4; 50-57
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Long-term water quality monitoring using Sentinel-2 data, Głuszyńskie Lake case study
Autorzy:
Ciężkowski, Wojciech
Frąk, Magdalena
Kardel, Ignacy
Kościelny, Marcin
Chormański, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/36055080.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
sentinel-2
inland water
biological oxygen demand
BOD
dissolved organic carbon
DOC
electrical conductivity
EC
chlorophyll concentration
CHL
Opis:
This study shows the results of long-term inland water monitoring using Sentinel-2 data for Głuszyńskie Lake in the years 2015–2022. Four water quality parameters: biological oxygen demand (BOD), dissolved organic carbon (DOC), chlorophyll concentration (CHL) and electrical conductivity (EC) were calculated according to formulas found in the literature. The results were validated based on measurements conducted in 2021 and 2022, where for BOD, DOC and CHL high determination coefficients (0.77 and 0.79) were observed, and the EC determination coefficient was equal to 0.45. The results show that empirical formulas can be used for qualitative analyses of inland water quality, while for quantitative analyses more extensive field work needs to be performed.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2022, 31, 4; 283-293
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podatność ścieków na rozkład biochemiczny w procesach mechaniczno-biologicznego oczyszczania
Susceptibility of wastewater for biochemical decomposition in mechanical - biological wastewater treatment processes
Autorzy:
Płuciennik-Koropczuk, E.
Jakubaszek, A.
Powiązania:
https://bibliotekanauki.pl/articles/372572.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
rozkład biochemiczny
zanieczyszczenia organiczne
ChZT
BZT
OWO (ogólny węgiel organiczny)
biochemical decomposition
organic pollutants
COD
BOD
TOC
Opis:
W pracy przedstawiono wyniki badań dotyczące wykorzystania współzależności między wskaźnikami zanieczyszczeń organicznych do oceny podatności ścieków na rozkład biochemiczny. Współczynniki wyznaczano dla ścieków po kolejnych procesach oczyszczania. Zmiany wartości ilorazów ChZT_Cr/BZT_5 i BZT_5/OWO w oczyszczalni w Zielonej Górze były typowe dla poprawnego procesu oczyszczania w układzie mechaniczno-biologicznym.
The paper presents results of research on the use of the relationship between indicators of organic pollutants to assess the suitability of the distribution of biochemical treatment. The coefficients were determined for wastewater after successive treatment processes. Changes in the value ratios of COD/BOD and BOD/TOC in WWTP in Zielona Gora were typical for the correct cleaning process in the mechanical-biological system.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2012, 148 (28); 73-83
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Analysis of the Amount of Pollutants in Wastewater after Mechanical Treatment in the Aspect of their Susceptibility to Biodegradation in the Treatment Plant in Nowy Targ
Autorzy:
Nowobilska-Majewska, Elwira
Bugajski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/123918.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
biodegradability
mechanical treatment
BOD5
COD
chemical oxygen demand
biochemical oxygen demand
total nitrogen
total phosphorus
Opis:
The aim of this study was to determine the biodegradability of organic and biogenic contaminants in wastewater flowing into biological reactors in the treatment plant in Nowy Targ. The research period covered the years 2016 and 2017, when 87 samples of raw wastewater and 87 samples of wastewater after mechanical treatment were collected and subjected to physico-chemical analysis. In both types of wastewater, the size of the following indicators was analyzed: BOD5, COD, total kjeldahl nitrogen (TN) and total phosphorus (TP). The study verified the amount of pollutants in the raw wastewater in order to determine whether they are household wastewater. In the next stage of the analysis, the characteristic values of the analyzed indicators in wastewater after the mechanical treatment process were determined in order to indicate mutual dependences of organic and biogenic indicators. Based on the analysis, it was found that wastewater after mechanical treatment (in the case of its susceptibility to biological decomposition processes of organic pollutants) has an unfavorable COD/BOD5 ratio. With regard to the susceptibility of wastewater to nitrification, denitrification and dephosphatation processes, in the majority of cases, wastewater is susceptible to these processes. It is recommended to apply an additional source of organic carbon to wastewater prior to biological treatment in order to improve the biodegradation of the analyzed pollutants.
Źródło:
Journal of Ecological Engineering; 2019, 20, 8; 135-143
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of organic substance removal in a hybrid sand filter with horizontal flow
Efekty usuwania substancji organicznej w hybrydowych filtrach piaskowych z przepływem poziomym
Autorzy:
Jóźwiakowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/292933.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BOD5
COD
efficiency
horizontal flow
sand filter
wastewater treatment
BZT5
ChZT
efektywność oczyszczania ścieków
filtr piaskowy
przepływ poziomy
Opis:
The paper presents the results of the research about the efficiency of organic substance removal in a hybrid sand filter. The investigations were carried out on a model wastewater treatment plant consisting of a preliminary sedimentation tank and two sand filter with a horizontal flow of wastewater (aerobic and anaerobic beds). The efficiency of BOD5 and COD removal was analysed for different wastewater hydraulic load levels: 0.72; 1.08; 1.44 dm3·d–1. The best efficiency of BOD5 and COD removal was obtained when the hydraulic load level was 1.08 dm3·d–1, respectively 83.8 and 72.3%. The average values of BOD5 and COD in the treated wastewater were significantly higher than the values deemed acceptable by relevant regulations in Poland. Based on the studies in the analyzed case, it was found that, sand filters with horizontal flow, do not guarantee high effluent treatment effect of typical household wastewater. In order to obtain a better efficiency of organic substance removal in a hybrid sand filter wastewater need to be oxygenate before being carried to these systems.
W pracy zaprezentowano wyniki dotyczące efektywności usuwania substancji organicznej w hybrydowych filtrach piaskowych. Badania prowadzono w modelowej oczyszczalni ścieków składającej się z osadnika wstępnego i dwóch filtrów piaskowych z poziomym przepływem. Efektywność zmniejszania BZT5 i ChZT była analizowana w warunkach różnego obciążenia hydraulicznego ściekami: 0,72; 1,08; 1,44 dm3·d–1. Najlepsze efekty obniżania BZT5 i ChZT uzyskano w warunkach obciążenia hydraulicznego na poziomie 1,08 dm3·d–1, odpowiednio 83,8 i 72,3%. Średnie wartości BZT5 i ChZT w oczyszczonych ściekach były zazwyczaj większe niż dopuszczalne w odpowiednich przepisach w Polsce. Na podstawie badań w analizowanym przypadku stwierdzono, że filtry piaskowe o przepływie poziomym nie dają gwarancji wysokiej sprawności oczyszczania ścieków bytowych. W celu uzyskania lepszych efektów eliminacji substancji organicznej w filtrach piaskowych konieczne jest napowietrzanie ścieków przed doprowadzeniem ich do tych systemów.
Źródło:
Journal of Water and Land Development; 2017, 35; 95-100
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations on the effectiveness of wastewater purification in medium sand with assisting opoka rock layer
Autorzy:
Kalenik, Marek
Chalecki, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2032948.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
drainage
infiltration
medium grain sand
BOD5
COD
treated sewage
drenaż
infiltracja
piasek średnioziarnisty
BZT5
ChZT
ścieki oczyszczone
Opis:
The objective of the undertaken investigations was to examine in laboratory conditions whether an introduction of an assisting opoka rock layer with the granulation of 1–6 mm into the ground improves the removal efficiency of nitrogen and phosphorus compounds from domestic sewage. The performed investigations concerned the layer supporting the removal efficiency of domestic sewage in a home sewage treatment plant under infiltration drainage. The model investigations of wastewater purification were carried out in a medium sand bed with an assisting, 0.10 and 0.20 m thick opoka rock layer. The effectiveness of wastewater purification related to basic qualitative indicators (total suspended solids – TSS, BOD5, COD, total nitrogen, total phosphorus) was in line with the Polish standards on sewage disposal into grounds and surface water. The medium sand soil bed with the 0.20 m thick assisting opoka rock layer showed higher effectiveness of wastewater purification than that 0.10 m thick. The application of the 0.20 m thick opoka rock layer increased the removal efficiency regarding TSS by 6.2%, total nitrogen by 20.4%, ammonium nitrogen by 8.3% and total phosphorus by 2.9%, and removal efficiency regarding BOD5 by 1.2% and COD by 1.9% with relation to the 0.10 m thick assisting layer (all percentages − in average). The results confirm that the natural opoka rock with the granulation of 1–6 mm can be used to assist in the removal of nitrogen and phosphorus compounds from wastewater with the application of infiltration drainage.
Źródło:
Environment Protection Engineering; 2021, 47, 1; 53-65
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and evaluation of sewage treatment plant operation
Analiza i ocena funkcjonowania oczyszczalni ścieków
Autorzy:
Gawdzik, J.
Długosz, J.
Powiązania:
https://bibliotekanauki.pl/articles/388727.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
waste water treatment plant
BOD5
biological treatment
removal efficiency
oczyszczalnia ścieków
BZT5
biologiczne oczyszczanie ścieków
skuteczność usuwania zanieczyszczeń
Opis:
The paper presents the analysis and evaluation of six sewage treatment plants. The effectiveness of wastewater treatment was assessed for the following treatment facilities: Barcza (O1), Opatow (O2), Ostrowiec (O3), Starachowice (O4), Sandomierz (O5) and Piaseczno (O6). The evaluation of plant operation was based on the amount of reduction of five selected pollution indicators: BOD5, COD, total suspension, total nitrogen and total phosphorus. In addition, COD/BOD5 ratios were determined, the reliability coefficient (RC) was calculated and the degree of use of sewage treatment plant capacity, in relation to pollutant loads, was assessed. The paper also analyzes the non uniformity coefficient that characterizes variation in sewage flow.
W pracy przedstawiono analizę oraz ocenę funkcjonowania sześciu oczyszczalni ścieków. Ocenie efektywności systemu oczyszczania poddano oczyszczalnie ścieków Barcza (O1), a także w Opatowie (O2), Ostrowcu Świętokrzyskim (O3), Starachowicach (O4), oraz w Sandomierzu (O5) i Piasecznie (O6). Oceny poprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Poza tym dokonano obliczeń stosunku ChZT/BZT5, jak i również obliczono współczynnik niezawodności WN oraz stopień wykorzystania przepustowości oczyszczalni ścieków ze względu na ładunki zanieczyszczeń. W pracy przeanalizowano również wartość współczynnika nierównomierności, który charakteryzuje zmienność dopływu ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2014, 21, 2; 199-209
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability of removal of selected pollutants in different technological solutions of household wastewater treatment plants
Niezawodność usuwania wybranych zanieczyszczeń w różnych rozwiązaniach technologicznych przydomowych oczyszczalni ścieków
Autorzy:
Marzec, M.
Powiązania:
https://bibliotekanauki.pl/articles/293268.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BOD5
COD
household wastewater treatment plants
technological reliability
total suspended solids
BZT5
ChZT
niezawodność technologiczna
przydomowe oczyszczalnie ścieków
zawiesina ogólna
Opis:
The reliability of removal of selected contaminants in three technological solutions of the household sewage treatment plants was analysed in this paper. The reliability of the sewage treatment plant with activated sludge, sprinkled biological deposit and hybrid reactor (activated sludge and immersed trickling filter) was analyzed. The analysis was performed using the Weibull method for basic indicators of impurities, BOD5, COD and total suspended solids. The technological reliability of the active sludge treatment plant was 70% for BOD5, 87% for COD and 66% for total suspended solids. In the sewage treatment plant with a biological deposit, the reliability values determined were: 30% (BOD5), 60% (COD) and 67% (total suspended solids). In a treatment plant with a hybrid reactor, 30% of the BOD5 and COD limit values were exceeded, while 30% of the total suspended solids were exceeded. The reliability levels are significantly lower than the acceptable levels proposed in the literature, which means that the wastewater discharged from the analysed wastewater treatment plants often exceeds the limit values of indicators specified in currently valid in Poland Regulation of the Minister of Environment for object to 2000 population equivalent.
W pracy przeanalizowano niezawodność usuwania wybranych zanieczyszczeń w trzech rozwiązaniach technologicznych przydomowych oczyszczalni ścieków: oczyszczalni z osadem czynnym, ze złożem biologicznym zraszanym oraz reaktorem hybrydowym (osad czynny i złoże biologiczne zanurzone). Analizę wykonano z wykorzystaniem metody Weibula w odniesieniu do podstawowych wskaźników zanieczyszczeń: BZT5, ChZT i zawiesiny ogólnej. Niezawodność technologiczna oczyszczalni z osadem czynnym kształtowała się na poziomie 70% w przypadku BZT5, 87% – ChZT i 66% – zawiesiny ogólnej. W oczyszczalni ścieków ze złożem biologicznym zraszanym wyznaczone wartości niezawodności wyniosły: 30% (BZT5), 60% (ChZT) i 67% (zawiesina ogólna). W oczyszczalni z reaktorem hybrydowym przekroczenie dopuszczalnej wartości BZT5 i ChZT miało miejsce w 30% przypadków, a zawiesiny ogólnej w 28%. Wyznaczone poziomy niezawodności są wyraźnie niższe od poziomów dopuszczalnych proponowanych w literaturze, co oznacza, że w ściekach oczyszczonych odpływających z analizowanych oczyszczalni często pojawiają się przekroczenia wartości granicznych wskaźników, określonych w aktualnie obowiązującym Rozporządzeniu Ministra Środowiska dla obiektów o wielkości poniżej 2000 RLM.
Źródło:
Journal of Water and Land Development; 2017, 35; 141-148
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany w usuwaniu biogenów ze ścieków bytowo-gospodarczych po wieloletniej eksploatacji oczyszczalni roślinno-glebowej
Changes in nutrient removal from domestic sewage after 7 years exploitation of a plant-soil treatment plant
Autorzy:
Kuczewski, K.
Kwiecińska, K.
Kozdraś, M.
Powiązania:
https://bibliotekanauki.pl/articles/338947.pdf
Data publikacji:
2004
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
azot amonowy
azot ogólny
BZT5
efekt oczyszczania
eksploatacja
fosfor
ammonium nitrogen
BOD5
exploitation
total nitrogen
total phosphorus
treatment efficiency
Opis:
W artykule przedstawiono zmiany skuteczności oczyszczania ścieków bytowo-gospodarczych po siedmiu latach eksploatacji oczyszczalni roślinno-glebowej, przeznaczonej do oczyszczania ścieków pochodzących ze wsi Brzeźno. Budowa i zasada pracy tej oczyszczalni różni się istotnie od oczyszczalni roślinno-gruntowych. W artykule przedstawiono efekty oczyszczania, które uzyskano po oddaniu jej do eksploatacji, w rozbiciu na okres zimowy i letni, oraz po siedmiu latach pracy. Analizie poddano następujące wskaźniki zanieczyszczeń: BZT5, stężenie azotu amonowego, azotu ogólnego oraz fosforu. Z badań wynika, że średnia skuteczność oczyszczania ścieków po siedmiu latach eksploatacji oczyszczalni, uwzględniająca okres zimowy i letni, wynosi: BZT5 - ponad 99%, fosforu - 97,3%, azotu ogólnego - 95,9%, a azotu amonowego - 99,5%. Średnia zawartość fosforu w ściekach oczyszczonych w latach 2002-2003 wyniosła 0,3 mg P·dm-³, azotu ogólnego - 4,8 mg N·dm-³, a azotu amonowego - 0,3 mgNNH4·dm-³.
The article shows changes in the efficiency of domestic sewage treatment after 7 years exploitation of a plant-soil treatment plant. The plant purifies domestic sewage from the village Brzeźno. The construction and operation principles of the plant-soil treatment plant differ markedly from constructed wetlands. The paper shows results of operation in the winter and summer periods after 7 years exploitation. Analysed parameters included: BOD5, ammonium nitrogen, total nitrogen and total phosphorus. The studies show that the mean sewage treatment efficiency amounts 99% for BOD5, 97.3% for total phosphorus, 95.9% for total nitrogen and 99.5% for ammonium nitrogen. Mean concentrations of total phosphorus, total nitrogen and ammonium nitrogen in treated sewage in the years 2002-2003 were 0.3 mg·dm-³, 4.8 mg·dm-³ and 0.3 mg·dm-³, respectively.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2004, T. 4, z. 2a; 547-557
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości wód powierzchniowych w basenach portowych w Świnoujściu
Water quality of the surfaces waters of the swimming pools port in Swinoujscie
Autorzy:
Daniszewski, P.
Draszawka-Bołzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/411844.pdf
Data publikacji:
2012
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
basen portowy
jakość wód
temperatura
pH
ChZTCr
BZT5
Cl
swimming pools port
natural water quality
temperature
COD-Cr
BOD5
Opis:
Celem niniejszej pracy było prześledzenie w okresie od 2004 do 2008 roku poziomu oraz dynamiki zmian w wodach basenów portowych Portu Świnoujscie parametrów ogólnych jakości wód. W pracy oznaczano wskaźniki ogólne wody: temperaturę, pH, ChZT-Cr, BZT5, Cl-. Wszystkie oznaczenia i obliczenia wykonywano według metod zalecanych przez Polskie Normy, stosując procedury analityczne opisane m.in. przez Dojlido, Elbanowska, Hermanowicza.
To estimate differentiation of water chemistry in reservoirs of swimming pools port in Swinoujscie, in time of 2004 - 2008. In arbitrary appointed times 5 physical and chemical indicators of water quality were determined to evaluate general status and water condition - temperature, pH, CODCr, BOD5, Cl -.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2012, 4; 96-102
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane parametry jakości wód w basenach portowych w Szczecinie
Selected parameters of water quality of the swimming pools port in Szczecin
Autorzy:
Daniszewski, P.
Draszawka-Bołzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/411875.pdf
Data publikacji:
2012
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
basen portowy
jakość wód
temperatura
pH
ChZTCr
BZT5
Cl
swimming pools port
natural water quality
temperature
COD-Cr
BOD5
Opis:
Celem niniejszej pracy było prześledzenie w okresie od 2004 do 2008 roku poziomu oraz dynamiki zmian w wodach basenów portowych Portu Szczecin parametrów ogólnych jakości wód. W pracy oznaczano wskaźniki ogólne wody: temperaturę, pH, ChZT-Cr, BZT5, Cl-. Wszystkie oznaczenia i obliczenia wykonywano według metod zalecanych przez Polskie Normy, stosując procedury analityczne opisane m.in. przez Dojlido, Elbanowska, Hermanowicza.
To estimate differentiation of water chemistry in reservoirs of swimming pools port in Szczecin, in time of 2004 - 2008. In arbitrary appointed times 5 physical and chemical indicators of water quality were determined to evaluate general status and water condition - temperature, pH, COD-Cr, BOD5, Cl -.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2012, 4; 103-111
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza statystycznej zmienności składu ścieków w mechaniczno-biologicznej oczyszczalni
Statistical analysis of wastewater composition changes in mechanical-biological wastewater treatment plant
Autorzy:
Płuciennik-Koropczuk, E.
Wojciech, M.
Powiązania:
https://bibliotekanauki.pl/articles/372466.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
zmiany składu ścieków
ChZT
BZT
OWO
zawiesina ogólna
statystyczne miary
wykres pudełkowy
korelacja
wastewater composition changes
COD
BOD
TOC
suspended solids
statistics measure
box-graph
correlation
Opis:
W pracy przedstawiono wyniki analizy statystycznej zmienności składu ścieków w kolejnych procesach mechaniczno-biologicznego oczyszczania. Rozkład stężeń zanieczyszczeń oraz podstawowe wartości statystyk opisowych przedstawiono za pomocą wykresów pudełkowych. Wykonano również oceny współzależności między wskaźnikami ChZTCr, BZT5 i OWO dla próbek ścieków po kolejnych procesach oczyszczania.
The paper presents the results of the statistical analysis of variability of the composition of the wastewater in the subsequent processes of treatment. Distribution of pollutant concentrations and the core values of descriptive statistics are presented in the form of graphs boxed. Also performed evaluation of the relationship between indicators COD, BOD5 and TOC in wastewater samples after subsequent treatment processes.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2013, 151 (31); 131-142
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków z małych przetwórni owocowo-warzywnych w oczyszczalniach hydrofitowych
The treatment of wastewater from small fruit and vegetable processing plants in the constructed wetlands
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339063.pdf
Data publikacji:
2003
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZTCr
substancja organiczna
ścieki z przetwórni owocowo-warzywnych
złoża hydrofitowe
BOD5
CODCr
organic substance
wastewater from fruit and vegetable processing plants
constructed wetland
Opis:
W pracy przedstawiono wyniki badań dotyczące oczyszczania ścieków z małych przetwórni owocowo-warzywnych w 4 oczyszczalniach hydrofitowych. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna – BZT5 tych ścieków wynosiło od 1 100 do 7 100 g O2·m-³, zaś ChZTCr, - od 1400 do 10 200 g O2·m-³. Średnia skuteczność usuwania substancji organicznej ze ścieków oczyszczanych na złożach hydrofitowych z podpowierzchniowym poziomym przepływem, wyrażona zmniejszeniem BZT5, wynosiła od 34 do 67%, a zmniejszeniem ChZTCr - od 31 do 71%, w zależności od obciążenia tych złóż ściekami. Lepsze, lecz jeszcze dalece niewystarczające rezultaty, uzyskano w złożu z przepływem pionowym. Średnie zmniejszenie wartości wskaźnika BZT5 sięgało tam 86,9%, a ChZTCr - 82,6%.
Efficiency of 4 constructed wetlands in contaminants removal from wastewater produced in fruit and vegetable processing plants has been investigated. The main contaminant in this wastewater, otherwise poor in N and P, was the organic substance. Its concentration as BOD5 was 1 100 to 7 100 g O2·m-³ and as CODCr - 1400 to 10 200 g O2·m³. Mean BOD5 and CODCr removal on 3 beds with the horizontal subsurface flow depended on the organic substances loading rates and varied in a wide range between 34 and 67 % for BOD5 and between 31 and 64 for CODCr. Better, but still very insufficient results were obtained on the bed with a vertical flow. Its mean removal of BOD5 reached 86.9 % and that of CODCr - 82.6 %.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2003, 3, 2; 119-128
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczalnie ścieków z małej przetwórni owocowo-warzywnej w złożach gruntowo-roślinnych z przepływem pionowym
Treatment of wastewaters from small fruit and vegetable processing plant in the reed bed systems with vertical flow
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/338470.pdf
Data publikacji:
2007
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZT
oczyszczalnia hydrofitowa
substancja organiczna
ścieki z przetwórni owocowo-warzywnej
BOD5
COD
organic matter
reed bed system
wastewater from fruit and vegetable processing plant
Opis:
Badano skuteczność oczyszczania ścieków z małej przetwórni owocowo-warzywnej w 4 złożach gruntowo-roślinnych z przepływem pionowym, porośniętych trzciną. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna. Jej zawartość, wyrażona w BZT5 i ChZT, wynosiła odpowiednio 1 500-8 000 i 2 000-13 000 g O2·m-³. Największą skuteczność oczyszczania osiągnięto na wpracowanym złożu piaskowym, znoszącym zadowalająco obciążenia tą substancją wyrażone w BZT5 do ok. 90 g O2·m-²·d-¹ i w ChZT - do ok. 110 g O2·m-²·d-¹. W przypadku wpracowującego się złoża piaskowo-żwirowego, wskaźniki te wyniosły tylko około 50 i 70 g O2·m-²·d-¹. Zastosowanie na takim samym złożu wzbogacania ścieków azotem, zmniejszającego stosunek BZT5 : N z około 200 do 70 powodowało zwiększenie wartości tych wskaźników odpowiednio do około 70 i 90 g O2·m-²·d-¹. Wyniki te osiągnięto, gdy temperatura odpływów ze złóż była większa niż 5°C. W przypadku temperatury 4-4,5°C wystarczającą skuteczność zapewniło zmniejszenie obciążenia złóż wyrażonego w BZT5 do ok. 50 g O2·m-²·d-¹ i w ChZT - do ok. 70 g O2·m-²·d-¹.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2007, T. 7, z. 2b; 177-184
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Całoroczne oczyszczanie ścieków z przetwórstwa owocowo-warzywnego w złożu hydrofitowym
Annual treatment of wastewater from small fruit and vegetable processing plant in the reed bed system with vertical flow
Autorzy:
Soroko, M.
Powiązania:
https://bibliotekanauki.pl/articles/339528.pdf
Data publikacji:
2011
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
BZT5
ChZT
substancja organiczna
ścieki z przetwórni owocowo-warzywnej
złoże hydrofitowe
BOD5
COD
organic matter
reed bed system
wastewater from fruit and vegetable processing plant
Opis:
Badano całoroczną skuteczność oczyszczania ściekow z małej przetworni owocowo-warzywnej w piaskowym złożu hydrofitowym z przepływem pionowym, porośniętym trzciną. W ściekach tych, ubogich w azot i fosfor, głównym zanieczyszczeniem była substancja organiczna. Jej zawartość, wyrażona w BZT5 i ChZT, wynosiła odpowiednio 1 500-11 800 g O2·m-³ i 2 000-17 000 g O2·m-³. Skuteczność jej usuwania zależała w dużym stopniu od temperatury złoża. W temperaturze powyżej 5°C znosiło ono zadawalająco obciążenia wyrażone w BZT5 do ok. 90 g O2·m-²·d-¹ i wyrażone w ChZT do ok. 130 g O2·m-²·d-¹. W temperaturze 3.5°C dopuszczalne okazały się obciążenia złoża wyrażone w BZT5 i ChZT odpowiednio do ok. 50 g O2· m-²·d-¹ i do ok. 70 g O2·m-²·d-¹. W temperaturze złoża 1-2°C dopuszczalne obciążenie wyrażone w ChZT wyniosło ok. 30 g O2 ·m-²·d-¹.
Annual efficiency was examined of the treatment of wastewater from small fruit and vegetable processing plant in a sandy hydrophyte bed with vertical flow overgrown by reed. The main pollutant in this wastewater poor in nitrogen and phosphorus was organic matter. Its concentration expressed in BOD5 and COD amounted to 1500–11 800 g O2·m-³ and 2000–17 000 g O2·m-³, respectively. The efficiency of its elimination depended to a large extent on reed bed temperature. At temperatures exceeding 5°C the reed bed satisfactorily withstood the load 90 g O2·m-²·d-¹ and about 130 g O2·m-²·d-¹ measured in BOD5 and COD, respectively. At temperatures of 3-5°C permissible organic matter loads were about 50 g O2·m-²·d-¹ and about 70 g O2·m-²·d-¹, respectively and at outflow temperatures of 1-2°C - 30 g O2·m-²·d-¹ expressed in COD.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2011, 11, 1; 289-298
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of wastewater temperature and concentration of organic compounds on the efficiency of ammonium nitrogen removal in a household treatment plant servicing a school building
Wpływ temperatury ścieków oraz związków organicznych na skuteczność usuwania azotu amonowego w przydomowej oczyszczalni przy budynku szkolnym
Autorzy:
Bugajski, Piotr
Kurek, Karolina
Jóźwiakowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/205398.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
household wastewater treatment plant
ammonium nitrogen
organic compounds BOD5
air temperature
wastewater temperature
przydomowa oczyszczalnia ścieków
azot amonowy
związki organiczne BZT5
temperatura powietrza
temperatura ścieków
Opis:
The aim of this study was to determine the impact of the temperature of wastewater in a biological reactor with activated sludge and the BOD5/N-NH4 ratio in the influent to the treatment plant on nitrification efficiency and the concentration of ammonium nitrogen in treated wastewater. Tests were carried out in a household wastewater treatment plant which collects and treats sewage from a school building and a teacher’s house. During the 3-year study, large fluctuations in the sewage temperature in bioreactor were noted which was closely related to the ambient temperature. There were also large fluctuations in the concentration of organic matter and the concentration of ammonium nitrogen in inflowing sewage. The influence of wastewater temperature in the bioreactor and the BOD5/N-NH4 ratio on the concentration of ammonium nitrogen in treated wastewater was determined using Pearson’s linear correlation. A statistical analysis showed that a 1°C decrease in the temperature of wastewater in the bioreactor increased the concentration of ammonium nitrogen in treated wastewater by 2.64 mgN-NH4·L-1. Moreover, it was found that nitrification depended on the ratio of BOD5 to the concentration of ammonium nitrogen in wastewater flowing into the bioreactor. An increase in the BOD5/N-NH4 ratio by 1 value led to a 5.41 mgN-NH4·L-1 decrease in the concentration of ammonium nitrogen.
Celem pracy było określenie wpływu temperatury ścieków w reaktorze biologicznym z osadem czynnym oraz stosunku BZT5/N-NH4 w ściekach dopływających do oczyszczalni na skuteczność procesu nitryfikacji i stężenia azotu amonowego w ściekach oczyszczonych. Badania prowadzono w przydomowej oczyszczalni, do której odpływają ścieki z budynku szkolnego oraz domu nauczyciela. W okresie 3-letnich badań odnotowano duże wahania temperatury ścieków w bioreaktorze co było ściśle związane z temperaturą otoczenia. Stwierdzono również duże wahania stężenia materii organicznej oraz stężenia azotu amonowego w ściekach dopływających. Analizę wpływu temperatury ścieków w bioreaktorze oraz stosunku BZT5/N-NH4 na stężenie azotu amonowego w ściekach oczyszczonych określono za pomocą korelacji liniowej Persona. W wyniku przeprowadzonej analizy statystycznej stwierdzono, że wraz obniżeniem temperatury ścieków w bioreaktorze o 1°C następuje zwiększenie stężenia azotu amonowego w ściekach oczyszczonych o 2,64 mgN-NH4·L-1. Ponadto stwierdza się, że proces nitryfikacji zależny jest od stosunku BZT5 do stężenia azotu amonowego w ściekach dopływających do bioreaktora. Wraz ze wzrostem zależności BZT5/N-NH4 o 1 maleje stężenie stężenia azotu amonowego o 5,41 mgN-NH4·L-1
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 31-37
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba opracowania modelu regresyjnego do szacowania wartości BZT5 ścieków komunalnych
An attempt at development of a regression model for estimating BOD5 values of municipal wastewater
Autorzy:
Kowalewski, Z.
Neverova-Dziopak, E.
Preisner, M.
Powiązania:
https://bibliotekanauki.pl/articles/237566.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ścieki komunalne
oczyszczalnia ścieków
BZT5
zawiesiny
związki azotu
modelowanie
szacowanie
model regresyjny
warunki eksploatacyjne
municipal sewage
water reclamation plant
BOD5
total suspended solids
nitrogen compounds
modeling
estimation
regression model
operation conditions
Opis:
Jednym z podstawowych składników ścieków komunalnych są zanieczyszczenia organiczne, których zawartość jest określana najczęściej na postawie ich biochemicznego zapotrzebowania na tlen (BZT5). W artykule opracowano prosty model regresyjny do szacowania wartości BZT5 ścieków komunalnych w celu zapewnienia bieżącej kontroli sprawności procesu biologicznego oczyszczania oraz możliwości optymalizacji warunków eksploatacji reaktorów biologicznych. Model opracowano na podstawie danych pochodzących z wieloletniego (1990–2000) monitoringu jakości ścieków w oczyszczalni Terrence J. O’Brien Water Reclamation Plant w Chicago (USA). Analizie statystycznej poddano wartości następujących wskaźników jakości ścieków dopływających do oczyszczalni: pH, BZT5, zawiesiny ogólne, azot amonowy, azot Kjeldahla oraz azotany. Wszystkie obliczenia wykonano w programie statystycznym R z nakładką R Studio w wersji 1.0.143. Do wyboru parametrów istotnych do budowy modelu zastosowano kryterium informacyjne Akaikego (AIC) oraz algorytm Leaps. Na podstawie wyników testowania sformułowano model regresyjny do szacowania wartości BZT5 ścieków komunalnych wykorzystujący zawartości zawiesin ogólnych oraz azotu Kjeldahla i azotanów w ściekach. Algorytm formułowania modelu regresyjnego, przydatnego do szybkiego uzyskiwania przybliżonych wartości BZT5 ścieków, może posłużyć do budowy podobnych modeli na potrzeby innych oczyszczalni ścieków, bez konieczności częstego wykonywania oznaczeń laboratoryjnych i długiego oczekiwania na ich wyniki.
One of the primary components of municipal sewage is organic pollution, the content of which is determined most often on the basis of its biochemical oxygen demand (BOD5). In the paper, a simple regression model was developed to estimate BOD5 values of municipal sewage in order to ensure ongoing effi ciency control of the biological treatment process and possibilities for optimizing the operating conditions of biological reactors. The model was developed from the long-term monitoring data (1990–2000) on wastewater quality in the Terrence J. O’Brien Water Reclamation Plant in Chicago (USA). Statistical analysis covered the following quality indicators for the sewage material fl owing into the treatment plant: pH, BOD5, total suspended solids, ammonium nitrogen, Kjeldahl nitrogen and nitrates. All calculations were made using a statistical program R with R Studio patch, version 1.0.143. Akaiki Information Criterion (AIC) and the Leaps algorithm were employed to select parameters relevant to constructing the model. Based on the results of model testing, the regression model for BOD5 values estimation in municipal wastewaters was formulated. The model employed parameters such as total suspended solids, Kjeldahl nitrogen and nitrates wastewater content. The algorithm of formulating the regression model that allows for quick generation of approximate BOD5 values in wastewater can be applied to development of similar models for other treatment plants, with no need for frequent laboratory testing and long wait for the results.
Źródło:
Ochrona Środowiska; 2018, 40, 1; 21-27
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-45 z 45

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies