Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pulikowski, K" wg kryterium: Autor


Tytuł:
Algae Proliferation on Substrates Immersed in Biologically Treated Sewage
Autorzy:
Garbowski, T.
Bawiec, A.
Pulikowski, K.
Wiercik, P.
Powiązania:
https://bibliotekanauki.pl/articles/952364.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
periphyton
microalgal biomass
artificial substrates
microalgal harvesting
Opis:
Due fast biomass production, high affinity for N and P and possibilities to CO2 sequestration microalgae are currently in the spotlight, especially in renewable energy technologies sector. The majority of studies focus their attention on microalgae cultivation with respect to biomass production. Fuel produced from algal biomass can contribute to reducing consumption of conventional fossil fuels and be a remedy for a rising energy crisis and global warming induced by air pollution. Some authors opt for possibilities of using sewage as a nutrient medium in algae cultivation. Other scientists go one step further and present concepts to introduce microalgal systems as an integral part of wastewater treatment plants. High costs of different microalgal harvesting methods caused introduction of the idea of algae immobilization in a form of periphyton on artificial substrates. In the present study the attention has focused on possibilities of using waste materials as substrates to proliferation of periphyton in biologically treated sewage that contained certain amounts of nitrogen and phosphorus.
Źródło:
Journal of Ecological Engineering; 2017, 18, 1; 90-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal Changes in the Reduction of Biogenic Compounds In Wastewater Treatment Plants Based on Hydroponic Technology
Autorzy:
Bawiec, A.
Pawęska, K.
Pulikowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/124103.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydroponic technology
treatment effectiveness
nutrients removal
Opis:
The study presents the results of the treatment of domestic and industrial wastewater with respect to the reduction of nitrogen and phosphorus compounds. The analysis encompasses the results of physical and chemical tests of effluents from two facilities based on hydroponic technology: wastewater treatment plants with hydroponic lagoons using the BIOPAX technology – Paczków, Poland and the Organica technology – Szarvas, Hungary. Monthly treatment effectiveness was determined basing on these analyses. The composition of wastewater flowing into the lagoon (after mechanical treatment) and wastewater discharged to the collector in 2009–2011 was subject to physical and chemical analysis in both facilities. The effluent quality was determined basing on the concentration of total phosphorus, total nitrogen and ammonium nitrogen. Mean annual results of the operation of both objects were high. For the wastewater treatment plant in Paczkow, operating in the BIOPAX technology, the effectiveness of treatment with respect to total nitrogen throughout the analysed period ranged from 76.9–84.4%. Total phosphorus was eliminated from wastewater with an effectiveness of 96.4–98.0%. Such high reduction level was caused by the application of additional precipitation process in the chambers of activated sludge reactor. The hydroponic plant in Szarvas (Organica technology) was characterised by a high effectiveness of reduction with respect to ammonium nitrogen: 92.0–93.0%, while the reduction of total phosphorus fell into the range 49.3–55.3%.
Źródło:
Journal of Ecological Engineering; 2016, 17, 2; 128-134
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seasonal changes in phosphorus load flowing out of small agricultural catchments
Autorzy:
Pulikowski, K.
Pawęska, K.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/124125.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water
catchment
season
load
phosphorus
Opis:
In this article distribution of monthly phosphorus loads flowing out of two agricultural catchments which are located in different physiographic conditions of Lower Silesia was analysed. Loads of phosphorus runoff from the catchment located in the piedmont part of Lower Silesia in each month rarely exceed 0.10 kg P · ha-1. The size of annual load is determined by loads obtained in two months of early spring. Much lower loads obtained for lowland catchment, located near Wroclaw. Values calculated for each month rarely exceed the value of 0.01 kg P · ha-1. Culmination of loads bringing away is a bit more extended in a time compared to the catchment located on Sudety Mts. Foreland. Much higher loads are observed during the period from January to April – this period has a major impact on the size of phosphorus load that flows out from this catchment during whole hydrological year. The obtained results clearly indicate that the threat of watercourses and water reservoirs supply in phosphorus compounds from agricultural land is periodic and it is particularly high during early spring. Phosphorus load flowing out from the analyzed catchments is very diverse. From facility located on Sudety Foothill in hydrological year, during research period, flowed away average 0.81 kg P · ha-1. Significantly lower values were obtained for second facility and it was average 0.15 kg P ha-1 during a year. The size of load discharged during a year is largely determined by amount of phosphorus load flowing out during winter half of the year (from XI to IV). In case of foothill catchment in this period flowed out average 0.56 kg P · ha-1, which presents 69% of annual load and in lowland catchment this percentage was even slightly higher and was 73%.
Źródło:
Journal of Ecological Engineering; 2015, 16, 1; 81-86
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena redukcji zanieczyszczeń w oczyszczalni hydroponicznej
Evaluation of reduction of pollutants in a hydroponic wastewater treatment plant
Autorzy:
Bawiec, A.
Paweska, K.
Zawalek, T.
Pulikowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/59638.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie hydroponiczne
skutecznosc oczyszczania
scieki bytowe
redukcja zanieczyszczen
scieki doplywajace
scieki oczyszczone
wskazniki zanieczyszczen
zawiesina ogolna
chemiczne zapotrzebowanie tlenu
biochemiczne zapotrzebowanie tlenu
azot ogolny
fosfor ogolny
Opis:
W pracy podjęto próbę oceny efektywności oczyszczania ścieków na obiekcie w Paczkowie, który jest eksploatowany w technologii hydroponicznej. W celu określenia efektywności pracy oczyszczalni w zakresie usuwania azotu, fosforu, zawiesiny ogólnej, BZT5 i ChZT, analizie poddano wyniki badań ścieków pobieranych na wlocie do oczyszczalni oraz ścieków oczyszczonych na wylocie z obiektu. Okres badawczy obejmował lata 2009 – 2011. Analiza uzyskanych danych wykazała, że skuteczność oczyszczania w odniesieniu do wszystkich parametrów nie spadała poniżej 77,0%. Największą skuteczność oczyszczania odnotowano dla zawiesiny ogólnej (99,0%), dla BZT5 i fosforu wynosiła ona minimum 98,0% i 98,1%, a dla ChZT – 94,8%. Najniższą skuteczność oczyszczania (jednak nie mniejszą niż 77,0%) uzyskano dla azotu ogólnego, którego dopuszczalne stężenie na odpływie z oczyszczalni zostało kilkukrotnie przekroczone w ciągu okresu badawczego. Na podstawie analiz wyników badań oraz przeprowadzonych studiów literaturowych stwierdzono, że blok hydrobotaniczny stanowiący trzeci stopień oczyszczania ścieków komunalnych pozwala na znaczną redukcję wartości poszczególnych zanieczyszczeń w odprowadzanych ściekach tak, aby możliwe było uzyskanie na odpływie wartości BZT5 poniżej 4,8 mgO2/dm3, ChZT w granicach 24,2-33,0 mgO2/dm3, zawiesiny ogólnej poniżej 3,4 mg/dm3, fosforu ogólne go nie więcej niż 0,3 mgP/dm3 oraz azotu ogólnego poniżej 20,4 mgN/ dm3. Uzyskane wyniki badań świadczą o tym, że makrofity oraz inna roślinność zasiedlająca lagunę hydroponiczną, posiadają zdolność redukcji stężeń związków biogennych w ściekach, co umożliwia odprowadzanie do odbiornika wód o lepszej jakości niż ta w nim płynąca.
The paper attempts to evaluate effectiveness of treatment of wastewater in sewage treatment plant in Paczków which is used in hydroponic technology. In order to determine the efficiency of wastewater treatment for the removal of nitrogen, phosphorus, suspended solids, BOD5 and COD, results of analyses of wastewater collected at the inlet of the treatment plant and at the outlet of the object were analyzed. Research period covered the years 2009 to 2011. Analysis of the data showed that the purification efficiency related to all parameters did not drop below 77.0%. The biggest effectiveness of sewage treatment was observed for total suspended solids (99.0%) for BOD and phosphorus it was at least 98.0% and 98.1%, and for COD – 94.8%. The lowest efficacy of treatment (but not less than 77.0%) was found for total nitrogen, which allowed concentration in sewage at the outlet from wastewater treatment plant has been exceeded several times during the study period. Based on the results of analyzes and literature studies was found that the hydroponic block which is tertiary step of urban wastewater treatment allows for considerable reduction of values of individual pollutants in discharged wastewater to make it possible to reach at the outlet values of BOD less than 4.8 mgO2/dm3, COD in the range 24.2-33.0 mgO2/dm3, total suspended solids below 3.4 mg/dm3, total phosphorus less than 0.3 mgP/dm3 and total nitrogen below the 20.4 mgN/dm3. Obtained results indicate that macrophytes and other hydroponic plants inhabiting the lagoon, have the ability to reduce the concentrations of nutrients in the wastewater, which allows drainage to receiver water of a better quality than the water flowing.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2013, 1/IV
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona zasobów wodnych przed zanieczyszczeniem azotanami pochodzenia rolniczego
The protection of waters against pollution caused by nitrates from agricultural sources
Autorzy:
Pulikowski, K.
Małecka, I.
Małecki, Z. J.
Moszinskij, V.
Powiązania:
https://bibliotekanauki.pl/articles/407590.pdf
Data publikacji:
2013
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
azotany
dyrektywa azotanowa
obszary szczególnie narażone
saldo bilansu azotu
nitrates
nitrates directive
nitrate vulnerable zones (NVZs)
nitrogen balance
Chief Sanitary Inspectorate
Opis:
Streszczenie: Proces wdrażania zapisów dyrektywy azotanowej w Polsce rozpoczął się w roku 2004, obecnie obszary szczególnie narażone (OSN) są pod drugiej korekcie, jaka miała miejsce w roku 2012. Wyznaczanie OSN nastręcza pewne trudności, stajemy przed koniecznością udowadniania KE, że w naszym kraju to zagrożenie jest mniejsze niż w innych krajach Europy. Analiza związków pomiędzy wielkościami OSN w poszczególnych województwach a bezpośrednimi czynnikami rolniczymi: nawożenie azotowe, saldo bilansu azotu, obsada zwierząt wykazała, że bezpośredni związek występuję tylko w odniesieniu do salda bilansu azotu. Jednak jednocześnie wysoką wartość tego wskaźnika stwierdza się w województwach, w których OSN nie występują. Wskazuje to na konieczność poszukiwania efektywniejszych metod wyznaczania OSN opartych na analizie wieloczynnikowej i wykorzystujących możliwości jakie dają metody GIS.
The process of implementing the nitrates directive began in 2004; at the moment nitrates vulnerable zones (NVZs) have already been corrected twice and the second correction was made in 2012. Designating NVZs poses certain problems as we need to prove to the European Commission that the risk of pollution in Poland is lesser than in other European countries. An analysis of the relationship between the size of NVZs in particular voivodships and direct agricultural agents such as the use of nitrogen fertilizers, the nitrogen balance and the livestock has shown a direct correspondence only in case of the nitrogen balance. At the same time, however, the nitrogen balance has been found to be high in voivodships where there are no NVZs. This indicates that there is a necessity to search for more effective methods of designating NVZs based on a multi-agent analysis and using the possibilities offered by Chief Sanitary Inspectorate.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2013, 8-9; 7-18
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków bytowo-gospodarczych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych
The efficiency of domestic sewage tretment in ground-plant and soil-plant treatment units
Autorzy:
Czyżyk, F.
Pulikowski, K.
Strzelczyk, M.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338757.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie glebowo-roślinne
oczyszczanie ścieków
reed bed system
soil-plant treatment
wastewater treatment
Opis:
Celem badań prezentowanych w pracy było rozpoznanie zmian efektywności oczyszczania ścieków bytowych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych w zależności od czasu i warunków ich eksploatacji. W pracy przedstawiono wyniki badań skuteczności oczyszczania ścieków w złożach gruntowo-trzcinowych, zbudowanych wg systemu Kickutha, oraz oczyszczalni glebowo-roślinnej w początkowym okresie eksploatacji (na 4 obiektach) i po 15 latach (na 2 obiektach). Zaskakujące były zdecydowanie różniące się wyniki, uzyskane w pierwszych latach eksploatacji, z dwóch podobnych złóż gruntowo-trzcinowych, których eksploatację rozpoczęto w tym samym roku. Na jednym skuteczność oczyszczania zwiększała się z upływem czasu, a na drugim wystąpiły objawy braku tlenu w złożu i słabej nitryfikacji azotu, co przejawiało się dużym stężeniem N-NH4 w odpływach z oczyszczalni. Przyczyną tego była błędna lokalizacja oczyszczalni - w miejscu silnie zacienionym, co wpłynęło na bardzo słaby rozwój trzciny i jej systemu korzeniowego, a tym samym na słabe napowietrzanie złoża. Z upływem lat eksploatacji pogarszała się przepuszczalność złóż dwóch badanych oczyszczalni gruntowo-trzcinowych i wystąpiło ich zakolmatowanie, powodowane głównie niedostatecznym oczyszczaniem wstępnym doprowadzanych ścieków. Stwierdzono znacznie wyższy stopień oczyszczania ścieków w oczyszczalni glebowo-roślinnej, zarówno w początkowym okresie eksploatacji, jak i po 15 latach. Uzyskane zmniejszenie głównych wskaźników zanieczyszczenia po 15 latach eksploatacji gruntowo-trzcinowych było następujące (w %): Nog - 47, Pog - 63, BZT5 - 93, ChZTCr - 81, natomiast na oczyszczalni glebowo-roślinnej: Nog - 84, Pog - 99, BZT5 - 95, ChZTCr - 74.
The aim of this study was to trace changes in the efficiency of domestic sewage treatment in soilplant and ground-plant systems in relation to the time and conditions of use. The paper presents results of testing the effectiveness of sewage treatment in ground reed beds constructed according to Kickuth system and in soil-plant treatment units, in the beginning of utilization period (in 4 objects) and after 15 years (in 2 objects). Surprising were the definitely different results obtained during the first years of utilization in two similar reed beds, which started operating in the same year. In one, the efficiency of treatment increased with time and in the other the symptoms of oxygen deficit and weak nitrification were observed in the bed which manifested itself in high N-NH4 concentrations in the outflow from the treatment unit. The reason was in faulty location of the treatment unit in an intensely shaded place resulting in poor development of reed and its root-rhizome system and, consequently, in poor aeration of the bed. In the two examined ground reed treatment units, the beds lost their permeability and became silted with time due mainly to insufficient primary sewage treatment. The soil-plant treatment unit showed considerably higher degree of sewage purification, both during the initial period of utilization and after 15 years. In ground reed beds, after 15 years of their utilization, the reduction of main pollutants was (in %): Ntot - 47, P - 63, BOD - 93, CODCr - 81, whereas in soil-plant treatment units it was: Ntot - 84, P - 99, BOD - 95, CODCr - 74.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 97-108
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności oczyszczania ścieków wiejskich w środowisku glebowo-roślinnym na podstawie badań lizymetrycznych
An assessment of the efficiency of rural sewage treatment in soil-plant system based on lysimetric studied
Autorzy:
Strzelczyk, M.
Pulikowski, K.
Steinhoff-Wrześniewska, A.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338690.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
azot
gleba
oczyszczanie
roślina
ścieki
nitrogen
plant
sewage
soil
treatment
Opis:
W pracy przedstawiono wyniki badań redukcji ładunku azotu odprowadzanego ze ściekami po ich glebowo-roślinnym oczyszczaniu w okresie od kwietnia 2009 r. do marca 2011 r. W pracy dokonano analizy skuteczności eliminacji azotu ogólnego w wyniku glebowo-roślinnego oczyszczania ścieków. W doświadczeniu zastosowano dwa gatunki roślin wieloletnich należących do grupy roślin energetycznych: miskant olbrzymi (Miscanthus giganteus Greef et Deu.) oraz ślazowiec pensylwański (Sida hermaphrodita (L.) Rusby). Badania prowadzono w lizymetrach o średnicy 1,0 m i głębokości 1,3 m, wypełnionych piaskiem gliniastym. W doświadczeniu zastosowano 2 warianty obciążenia gleby ściekami (I - 1200 mm·r-¹ i II - 1600 mm·r-¹). Wyniki badań z obu wariantów świadczą o dużej skuteczności usuwania azotu ogólnego zawartego w ściekach w poszczególnych miesiącach, wynoszącej od 84 do 100%. Wskazały również na wpływ warunków atmosferycznych determinujących wielkość odcieków, a co za tym idzie - ilość składników wymywanych z gleby
The paper presents the results of studies on the reduction of nitrogen load in soil-plant treatment of waste waters in the period from April 2009 to March 2011. Two perennial energetic plants: Miscanthus giganteus and Sida hermaphrodita Rusby were used in the study. The experiment was performer in lysimeters of a diameter of 1.0 m and depth 1.3 m filled with loamy sand. Sewage loads applied in the experiment were 1200 mm·year-¹ (variant I) and 1600 mm·year-¹ (variant II). Both variants showed a high effectiveness of total N removal which ranged from 84 to 100% in particular months. They also demonstrated the effect of atmospheric conditions which determined the amount of drainage and hence the quantity of components washed out from the soil and the seasonal variability of nitrogen removal from waste waters
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 267-279
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognozowany wpływ budowli parku wodnego na zagrożenie powodziowe osiedla Rajsków w Kaliszu
Forecast impact of building a water park on flood risksin Rajsków housing estate, Kalisz
Autorzy:
Małecki, Z. J.
Wira, J.
Pulikowski, K.
Małecka, I.
Powiązania:
https://bibliotekanauki.pl/articles/407586.pdf
Data publikacji:
2012
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
powódź
fala powodziowa
wody gruntowe
infiltracja
sufozja gruntu
tereny zalewowe
budowle hydrotechniczne
flood
flood vave
underground water
infiltration
soil suffosion
floodplain
hydro-engineering structures
Opis:
Teren budowy Parku Wodnego, znajduje się między rzeką Prosną i jej rozwidleniem nazywanym Kanałem Bernardyńskim a rzeką Swędrnią będącą prawostronnym dopływem Kanału Bernardyńskiego. W oparciu o dane hydrologiczne z okresów powodzi wynika, że woda stuletnia osiąga w tym rejonie rzędną 103,48 m n.p.m. i jest ponad 1,0 m wyższa od rzędnej istniejącego terenu. Natomiast woda dziesięcioletnia już zalewa (podtapia) teren znajdujący się pomiędzy rozwidleniem rzek: Swędrni i Prosny. Grunty terenu zalewowego rozpoznane wierceniami do głębokości od 5,0 do 10 m p.p.t. zbudowane są z czwartorzędowych piaszczystych utworów akumulacji rzecznej z odłożoną w stropie, warstwą osadów akumulacji zastoiskowo - bagiennej zalegającej na głębokości od 0,65 m do 3,30 m p.p.t. Natomiast osady akumulacji rzecznej zalegają pod w/w osadami akumulacji zastoiskowo - bagiennej do głębokości od 8,0 do 10 m p.p.t. Warstwę powierzchniową stanowi gleba o miąższości od 0,20 do 0,80 m (śr. 0,40 ,) oraz nasypy niekontrolowane piaszczysto - próchniczo - pyłowe o miąższości od 0,20 do 1,60 m. W gruncie stwierdzono występowanie swobodnego i napiętego zwierciadła wody gruntowej w piaskach akumulacji rzecznej. Ustabilizowane zwierciadło wody gruntowej, posiadającej bezpośredni kontakt hydrauliczny z wodą w obu rzekach, występuje na głębokości 0,65 - 1,84 m p.p.t o spadku w kierunku północnym, tj. w stronę rzeki Swędrni. W oparciu o wieloletnie obserwacje należy stwierdzić, że przepływy wezbraniowe w Swędrni występują z reguły w tym samym okresie co w rzece Prośnie. Budynek główny Parku Wodnego posadowiony jest na żelbetowych ławach fundamentowych co z upływem czasu w następstwie sufozji gruntu, wraz ze zwiększeniem współczynnika filtracji wody w gruncie będzie skutkowało, zmniejszeniem stabilności statycznej budowli jak i zwiększoną infiltracją wód w gruncie z rzeki Prosny do Swędrni. W następstwie prognozowanej większej infiltracji wód m.in. w otoczeniu fundamentowania budowli Parku Wodnego, skutkować będzie przyśpieszonymi znacznymi podtopieniami (zalewaniem) terenów przyległych Osiedla Rajsków. W przypadku wystąpienia wysokich stanów wód w rzekach w celu ograniczenia skutków negatywnych związanych z podtopieniami terenów zalewowych Osiedla Rajsków należy po wykonaniu studium technicznego, m.in. wykonać drenaż powierzchni i stopy skarpy wału przeciwpowodziowego wraz ze wzmocnieniem skarpy odwodnej na odcinku od mostu Bursztynowego do początku Kanału Bernardyńskiego. Natomiast w przypadku wystąpienia fali powodziowej przekraczającej stan alarmowy przez dłuższy okres czasu, wszelkie dodatkowe budowle hydrotechniczne dają z dużą dozą prawdopodobieństwa efekt niezadowalający w stosunku do założonego (podtopienie wraz z zalaniem terenów przyległych do cieków).
The area of building a water park is situated between the Prosna river and its fork, the Bernardyński Canal and the Swędrnia river, which is a right-hand side tributary of the Bernardyński Canal. Based on hydrological data from flood periods, the centenary water seems to reach in this area an elevation of 103.48 m above the sea level and is 1.0 m higher than the elevation of the existing land. However, the ten-year water already floods (permeates) the area located between the fork of the Swędrnia and the Prosna. The flood plain examined with drilled holes of 5.0 - 10.0 m in depth is composed of quaternary sand formations of river accumulation with a layer of accumulation deposit of marginal and swampy nature sitting at 0.65 to 3.30 m below the surface. On the other hand, the river accumulation deposits are located under the said marginal and swampy accumulation deposits from 8.0 to 10 m below the surface. The surface layer is made of soil of 0.20 - 0.80 (avg. 0.40) thickness and uncontrolled sand - humus and dust windrows of 0.20 - 1.60 m thickness. The ground has been found to contain free and high-pressure underground water mirror in the river accumulation sand. A stable mirror of the underground water, which has a direct contact with the water in both rivers, can be found at the depth of 0.65 - 1.84 m below the surface with the slope towards north, i.e. towards the Swędrnia river. Based on long-term observations it has to be said that high-level flows in the Swędrnia basically occur at the same time as in the Prosna. The main building of the water park is founded on reinforced concrete footing, which with time, as a consequence of soil suffusion and increase of water filtration ratio in the soil will result in lower static stability of the building as well as increased water filtration in the soil from the Prosna to the Swędrnia. As a result of forecast higher infiltration of the waters surrounding the foundation of the water park building, the adjoining housing estate called Rajsków will be subject to accelerated permeation (flooding). In the case of high water levels in the rivers, in order to mitigate adverse effects of permeation of the Rajsków flood plain, an engineering study has to be followed by drainage of the surface and the foot of the levee slope along with reinforcement of the downstream slope between the Bursztynowy bridge and the onset of the Bernardyński Canal. However, in the case of a flood wave exceeding the alarm level for a long time, any additional hydro-engineering structures are very likely to deviate from the assumed target (permeation and flooding of areas adjacent to the water-courses.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2012, 5-6; 9-30
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognozowany wpływ projektowanego zbiornika Wielowieś Klasztorna w zlewni Prosny na gospodarkę wodną
Anticipated impact of a future reservoir within the prosna basin in Wielowieś Klasztorna upon water conditions
Autorzy:
Małecki, Z. J.
Pulikowski, K.
Wira, J.
Powiązania:
https://bibliotekanauki.pl/articles/1203864.pdf
Data publikacji:
2012
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
zbiornik retencyjny
wody gruntowe
przepływ wód
fala powodziowa
gospodarka wodna
ochrona czynna przeciwpowodziowa
retention reservoir
underground water
water flow
flood wave
water management
active flood protection
Opis:
Zbiornik retencyjny Wielowieś Klasztorna o powierzchni 1704,0 ha (przy max. p.p. 124,0 m n.p.m.) i pojemności max. 48,8 mln m3, wprowadzi zasadniczą poprawę w zakresie ochrony doliny Prosny przed zagrożeniem powodziowym. Po wschodniej stronie zbiornika oddziaływanie na poziom wód gruntowych wiązać się będzie przede wszystkim ze strefą doliny Prosny przylegającą bezpośrednio do granicy spiętrzonej wody powierzchniowej wraz z dolinami ujściowych odcinków dopływów Prosny. Wystąpi zredukowanie maksymalnych przepływów powodziowych poprzez złagodzenie (spłaszczenie) fali powodziowej a tym samym zauważalna będzie ochrona czynna, znacząco łagodząca skutki powodziowe dla miasta Kalisza. W drzewostanach pozostawionych w suchej strefie zbiornika, co kilka lub kilkadziesiąt lat będzie dochodziło do okresowego stagnowania wody na powierzchni gleby (obniżenie żyzności drzew, przekształcenie siedlisk w bardziej wilgotne i żyźniejsze).
The retention reservoir in Wielowieś Klasztorna covering 1704.0 ha (max. 124.0 m above sea level) and max. capacity of 48.8 mln m3 is going to significantly improve protection of the Prosna valley from flood risk. On the reservoir’s eastern side, the impact upon underground water will be connected with the Prosna valley zone adjacent to the borderline of surface backwater including valleys of the Prosna’s tributaries. Maximum flood flows will be reduced by mitigating (flattening) the flood wave and thereby active protection will become noticeable diminishing flood effects for Kalisz town. Every few or a few dozen years the forest stand left in the reservoir’s dry zone will be subject to periodic water stagnation on the soil surface (reduced tree fertility, transformation of habitats into more humid and fertile ones).
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2012, 7; 9-22
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Udział azotu azotanowego w ogólnej zawartości azotu w wodach odpływających ze zlewni użytkowanych rolniczo
Participation of nitrate nitrogen in total nitrogen content in waters outflowing from catchment with agricultural use
Autorzy:
Pulikowski, K.
Czyzyk, F.
Paweska, K.
Strzelczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/61320.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
zlewnie rolnicze
wody odplywowe
odcieki drenarskie
wody powierzchniowe
zawartosc azotu
azot azotanowy
azot ogolny
Opis:
W pracy przeanalizowano wyniki badań zawartości azotu azotanowego i ogólnego w odciekach drenarskich i wodach powierzchniowych pochodzących z dwóch obiektów położonych na Dolnym Śląsku. Szczegółowej analizie poddano udział azotanów w ogólnej zawartości azotu. Odcieki drenarskie charakteryzowały się znaczną zawartością azotu ogólnego: średnie stężenie w okresie badawczym wynosiło od 22,4 mg N • dm-3 do 36,9 mg N • dm-3. W odciekach drenarskich, pochodzących z różnych działów drenarskich, stosunek N-NO3:N nie wykazywał istotnych różnic i zawierał się w granicach 75 88%, mimo, że wody te różniły się istotnie zawartością azotu ogólnego i azotanowego. Odprowadzenie odcieków drenarskich zasobnych w związki azotowe na obu obiektach powodowało wzrost średnich stężeń azotu ogólnego w wodach powierzchniowych. W półroczu letnim wody te wykazywały mniejszy stosunek N-NO3:N, co należy tłumaczyć intensywnym pobieraniem tego jonu przez rośliny w okresie wegetacji. Niezależnie od analizowanego półrocza wyższy udział azotanów stwierdzano w wodach poniżej obiektu. Jedynie w przypadku obiektu nizinnego różnice te były istotne dla poziomu istotności p=0,05. Mniejszy udział azotu azotanowego w ogólnej zawartości azotu w wodach powierzchniowych sprzyjał większym wahaniom stosunku N-NO3:N.
In paper analyzed the results of research concerning nitrate and total nitrogen content in drainage effluents as well as surface water coming from facilities located in Lower Silesia area. Detailed analysis were made for participation of nitrate nitrogen in total nitrogen amount. Drainage effluents were characterized by significant content of total nitrogen: average concentration in research period amounted from 22,4 mg N ⋅ dm3 to 36,9 mg N ⋅ dm3. In drainage effluents, derived from different drainage section, relation N-NO3:N didn’t show significant differences and was in the range 75-88%, despite the fact that this water differed significantly of total and nitrate nitrogen content. The increase of average concentration of total nitrogen in surface water for both research objects was cause by outflowing drainage effluents that were reached in nitrogen compounds. In drainage water in summer period showed smaller relation N-NO3:N, what should be explain by intensive absorbing this ion by plants in vegetation period. Regardless of the analyzed period, there was found higher proportion of nitrate in water below research object. Only in case of lowland object these differences were significant for significant level p=0,05. The more fluctuation of relation N-NO3 conducive smaller participation of nitrate nitrogen in total nitrogen amount in surface water.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2012, 3/I
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany stężeń fosforu ogólnego w odpływach z kolejnych stopni złoża roślinno-gruntowego
Changes in total phosphorus concentrations in effluents from following beds of constructed wetland
Autorzy:
Paweska, K.
Pulikowski, K.
Strzelczyk, M.
Steinhoff-Wrzesniewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/60335.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie gruntowo-roslinne
efektywnosc oczyszczania
zloza gruntowo-roslinne
fosfor ogolny
stezenie fosforu
zmiany stezenia
Opis:
W pracy przedstawiono wyniki badań dotyczących zmian stężeń fosforu ogólnego na odpływie z kolejnych złóż gruntowo-roślinnej oczyszczalni w Paszkowie. Analizowano ścieki bytowe wprowadzane na cztery złoża pracujące w technologii constucted wetland. Złoża zaprojektowano z poziomym przepływem podpowierzchniowym w konfiguracji mieszanej (szeregowo - równoległej). Ocenie poddano skład ścieków bytowych wprowadzanych na złoża jak również skład fizyko-chemiczny odpływów. Badania prowadzono w okresie VII 2008 - III 2011. Stwierdzono średnią skuteczność pracy obiektu dla fosforu ogólnego na poziomie 40,0 %, przy czym najwyższe roczne efekty pracy obserwowano dla złoża 1. Średnie stężenie fosforu ogólnego w ściekach odprowadzanych do odbiornika wynosiło 4,4 mgP∙dm-3. Ze względu na warunki jakim powinien odpowiadać odpływ z oczyszczalni dla RLM < 2000, oczyszczalnia spełniała warunki jedynie dla wartości BZT5 i ChZT. W przypadku zawiesiny przekroczenia dopuszczalnych norm obserwowano przez cały okres badawczy.
The paper presents results of research concerning changes in total phosphorus concentrations from outflow from following beds of constructed wetland in Paszkow. There was analyzed domestic wastewater which was supplied to the four beds made as constructed wetland. The beds were designed with horizontal subsurface flow in a mixed configuration (serial – parallel). The evaluation assessed the composition of domestic wastewater supplied to the beds and as well as physico-chemical composition of the outflows. The research was conducted during July 2008 – March 2011. It was found that the average treatment efficiency for total phosphorus was at 40,0 %, with the highest annual treatment effects were observed for bed no.1. The average concentration of total phosphorus in the effluent discharged to the receiver was 4,4 mgPdm-3. Due to requirements to be met by the outflows form wastewater treatment plants for P.E < 2000, the wastewater treatment plant meets the conditions only for values of BOD5 and COD. In the case of the suspension exceeded to the limit values were observed during whole research period.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2012, 3/I
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja jazu franciszkańskiego na rzece Prośnie
Modernization of franciscan weir on the Prosna river
Autorzy:
Małecki, Z. J.
Pulikowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/407568.pdf
Data publikacji:
2011
Wydawca:
Instytut Badawczo-Rozwojowy Inżynierii Lądowej i Wodnej Euroexbud
Tematy:
jaz zasuwowy
gospodarka wodna
rumowisko
karbonatyzacja betonu
fala powodziowa
modernizacja
gate-controlled weir
water management
rubble
concrete carbonatization
flood wave
modernization
Opis:
W roku 1875 wybudowano jaz zasuwowy, wpisany do rejestru zabytków, na rzece Prośnie (km 65+40) w pobliżu klasztoru Franciszkanów w Kaliszu, wchodzący w skład Kaliskiego Węzła Wodnego (KWW). Podstawowym zadaniem jazu Franciszkańskiego (klasa ważności II, światło 3-przęsłowego jazu 11.17 m) jest utrzymanie zwierciadła wody na poziomie pomiędzy minimalnym, i maksymalnym zapewniającym normalną pracę małej elektrowni wodnej, jak również prawidłowej gospodarki wodnej w KWW. Jesienią 2011 r. wykonano prace remontowe i modernizacyjne jazu Franciszkańskiego, który wpisuje się w regulację (sterowanie) gospodarką wodna w KWW.
In 1875 a gate-controlled weir, entered in the list of monuments, was built on the Prosna river (km 65+40) near a Franciscan monastery in Kalisz, as a part of Kalisz Water Loop (KWL). The basic function of the Franciscan weir (II importance class, 11.17 m inside diameter of three-span weir) is to keep the water mirror between the minimum and maximum level to ensure regular operation of a small water power plant as well as proper water management in KWL. In autumn 2011 the Franciscan weir was renovated and modernized as part of the water management adjustment in KWL.
Źródło:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska; 2011, 4; 39-49
2082-6702
Pojawia się w:
Zeszyty Naukowe. Inżynieria Lądowa i Wodna w Kształtowaniu Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Na, k, ca and mg concentrations in effluent water drained from agricultural catchment basins in lower silesia
Stężenie na, k, ca i mg w wodach odpływających ze zlewni użytkowanych rolniczo na dolnym śląsku
Autorzy:
Pokladek, R.
Kowalczyk, T.
Orzepowski, W.
Pulikowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/15892.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie / Polskie Towarzystwo Magnezologiczne im. Prof. Juliana Aleksandrowicza
Opis:
This paper contains the results of research of the content Na, K, Ca and Mg in waters drained from three agricultural river basins in Lower Silesia. The investigations covered two objects situated close to Wroc³aw and one in the border region between the Bolków- Wa³brzych Plateau and the Wa³brzych Mountains. The effect of the agricultural use of the land on changes in the concentrations of the analyzed macroelements in the water flowing from the river basins has been assessed. Between 58 and 91 samples of waters for chemical analyses were taken once a month. Our analysis has shown that the concentrations of the analyzed elements were considerably different, both in the water flowing into and from the basins. The effluent water from the river basins was characterized by an elevated content of calcium and low concentrations of potassium. However, the content of magnesium was typical for the conditions in Poland. The content of magnesium in waters drained from all the river basins was higher than in the water flowing into the basins and the correlation coefficients for the concentrations in both of these cross-sections ranged from 0.7846 to 0.8603. Likewise, for sodium, calcium and potassium, dependences were found between the concentrations of these elements above and below the analyzed objects but the correlation coefficients were lower. Distinctly lower values of the correlation coefficients were obtained for the village of Samotwór. The agricultural use of the river basin area contributed to a higher magnesium and calcium content in waters and an insignificantly raised content of sodium. These changes were accompanied by a decrease in the concentration of potassium. It has been found out that differences in the Na : K : Ca : Mg ratio between the seasons of the year (early spring, late summer) are connected with the dynamics of the calcium concentration. The growth in the concentration of this element caused evident differences in the Ca : Mg ratio, reaching 0.7 to 1.2. An increase in the value of the Ca : Mg ratio in late summer reduces the outflow of potassium in most cases. Agricultural practice does not show any direct influence on seasonal changes of the Ca : Mg ratio and its effect on the value of this ratio is not unambiguous.
W pracy przedstawiono wyniki badań zawartości: Na, K, Ca i Mg w wodach odpływających z trzech zlewni użytkowanych rolniczo na Dolnym Śląsku. Badania realizowano na dwóch obiektach położonych w pobliżu Wrocławia i jednym na pograniczu Pogórza Bolkowsko-Wałbrzyskiego i Gór Wałbrzyskich. Ocenie poddano wpływ sposobu rolniczego użytkowania gleb na zmiany stężenia analizowanych makroelementów w wodzie odpływającej ze zlewni. Próbki wody do analiz chemicznych pobierane były raz w miesiącu, ich liczba wynosi ła od 58 do 91. Analiza wykazała że stężenia tych składników, zarówno w wodzie dopływającej, jak i odpływającej z tych obiektów, istotnie się różnią. Woda odpływająca ze zlewni miała podwyższoną zawartość wapnia i niskie stężenie potasu. Natomiast zawartość magnezu była typowa dla warunków polskich. Zawartość magnezu w wodach odpływających ze wszystkich zlewni była wyższa niż w wodzie dopływającej, współczynnik korelacji między stężeniami w obu tych przekrojach wynosił od 0,7846 do 0,8603. Dla sodu, wapnia i potasu również uzyskano istotne zależności między stężeniem powyżej i poniżej obiektu, ale współczynniki korelacji były niższe. Zdecydowanie niższe wartości współczynnika korelacji uzyskano dla Samotworu. Rolnicze użytkowanie zlewni sprzyjało zwiększeniu w wodach zawartości magnezu, wapnia i w niewielkim stopniu sodu oraz obniżeniu koncentracji potasu. Stwierdzono, że zróżnicowanie stosunku Na : K : Ca : Mg w poszczególnych okresach (przedwiośnie, późne lato) jest związane z dynamiką stężenia wapnia. Wzrost stężenia tego pierwiastka spowodował widoczne różnice w stosunku stężeń Ca:Mg, wynoszące od 0,7 do 1,2. Wzrost wartości stosunku Ca : Mg w okresie późnego lata sprzyja w większości przypadków ograniczeniu odpływu potasu w tym okresie. Działalność rolnicza nie wykazuje bezpośredniego wpływu na sezonowe zmiany stosunku Ca : Mg, również jej oddziaływanie na wartość tego stosunku nie jest jednoznaczne.
Źródło:
Journal of Elementology; 2011, 16, 3
1644-2296
Pojawia się w:
Journal of Elementology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Osadnik gnilny – podstawowy element przydomowej oczyszczalni ścieków
Septic tank – basic element of household treatment plant
Autorzy:
Paweska, K.
Pulikowski, K.
Strzelczyk, M.
Rajmund, A.
Powiązania:
https://bibliotekanauki.pl/articles/61439.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnie sciekow
oczyszczalnie przydomowe
osadniki gnilne
mechanizm dzialania
oczyszczanie sciekow
efektywnosc oczyszczania
Opis:
Właściwa gospodarka ściekowa na terenach wiejskich jest zagadnieniem trudnym, zwłaszcza, iż w dalszym ciągu widoczna jest dysproporcja pomiędzy stopniem zwodociągowania a skanalizowania gmin. Z roku na rok długość sieci kanalizacyjnej zwiększa się, co świadczy o podejmowaniu przez gminy działań mających na celu poprawę stanu sanitarnego. Zgodnie z Krajowym Programem Oczyszczania Ścieków Komunalnych [Krajowy Program Oczyszczania Ścieków Komunalnych 2010] jeżeli budowa kanalizacji jest nieuzasadniona, gmina powinna rozwiązać problem utylizacji ścieków we własnym zakresie. W pracy przedstawiono podstawowy obiekt przydomowej oczyszczalni ścieków (POŚ) - osadnik gnilny. Odpowiedzialny jest on przede wszystkim za mechaniczne oczyszczanie ścieków z części stałych oraz za wstępną stabilizację (beztlenową) osadów. Autorzy zwrócili uwagę na jakość ścieków doprowadzanych do zbiorników jak również odprowadzanych na kolejne stopnie oczyszczania. W pracy oprócz studiów literaturowych zawarto wyniki kilkuletnich obserwacji parametrów ścieków po mechanicznym oczyszczeniu. Podawane w literaturze skuteczności pracy kształtują się na poziomie 40,0-94,0% dla zawiesiny, 23,3 - 66,0% dla BZT5. Najniższa redukcja obserwowana była dla związków azotu i fosforu.
Proper wastewater management in rural areas is a difficult issue, especially that we can still see a disparity between the level of water service coverage and canalization of municipalities. The length of sewerage network increases every year, which indicates that municipalities are taking actions to improve sanitary condition. According to the National Program for Municipal Wastewater [Krajowy Program Oczyszczania Ścieków Komunalnych 2010], if the construction of sewage system is not justified, the municipality should solve the problem of waste disposal on their own. The paper presents the basic object at household sewage treatment plant – the septic tank. The septic tank is responsible primarily for the mechanical treatment of wastewater from the solids and for the initial stabilization (anaerobic) sediments. The authors paid attention to the quality of wastewater supplied to the tanks as well as wastewater delivered to the next steps of purification. The article, except study of literature includes results of several year of observations concerning parameters of wastewater after mechanical purification. According to the literature, the effectiveness of the operation is at the level of 40–94% for the suspension, 23,3–66,0% for BOD5. The lowest reduction was observed for compounds of nitrogen and phosphorus.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 10
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sezonowe zmiany wielkości ładunku azotu odpływającego z mikrozlewni użytkowanych rolniczo
Seasonal changes in the size of nitrogen load outflowed from micro-catchments used for agricultural purposes
Autorzy:
Pulikowski, K.
Czyzyk, F.
Paweska, K.
Strzelczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/61648.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
mikrozlewnie rolnicze
ladunek azotu
ladunek dobowy
odplyw azotu
zmiany sezonowe
zlewnie nizinne
zlewnie podgorskie
czynniki atmosferyczne
opady atmosferyczne
Opis:
W pracy przedstawiono wyniki badań wielkości dobowego ładunku azotu ogólnego odpływającego systemami drenarskimi i rowami melioracyjnymi na Dolnym Śląsku. Wielkość dobowego ładunku wykazuje duże zróżnicowanie sezonowe. Maksymalne ładunki dobowe stwierdzano na obiekcie położonym w terenie podgórskim wynosiły one dla sieci drenarskiej 6,27 kg N • d-1 • ha-1, dla rowu za-notowano aż 12,2 kg N • d-1 • ha-1. Zdecydowanie niższe wartości stwierdzono na obiekcie nizinnym. W warunkach nizinnych zagrożenie zanieczyszczeniem wody odbiornika azotem odpływającym z użytków rolnych występuje głównie w okresie wczesno wiosennym. Na obiekcie położonym na przedgórzu, charakteryzującym się większymi opadami, występuje drugi okres krytyczny przypadający na lipiec i sierpień. Ładunek azotu wynoszony ze zlewni pogórskiej w okresie roku to aż 75,5 kg N • ha-1, natomiast ze zlewni nizinnej odpływało znacznie mniej azotu - 12,7 kg N • ha-1. Przeprowadzone badania i analiza jednoznacznie wskazują, że o wielkości ładunku azotu wynoszonego ze zlewni w znacznym stopniu decyduje przebieg warunków atmosferycznych, a zwłaszcza wysokość opadów.
The paper presents the results of the survey of the daily load of total nitrogen outflowed with drainage system and ditches in Lower Silesia. The volume of daily load shows large seasonal variation. The maximum daily loads were found in object located in the submontane area. These loads amounted for the drainage systems 6,27 kg N ⋅ d-1 ⋅ ha-1 and for the ditches were noted until 12,2 kg N ⋅ d-1⋅ ha-1. Significantly lower values were found in the lowland object. In lowland area, risk of polluting the receiver with total nitrogen effluents from agricultural areas, occurs mainly during early spring. At the object located in the submontane area, which is characterized by greater rainfall, there is a second critical period attributable to the July and August. Load of nitrogen outflowed from submontane catchment during the year was 75,5 kg N ⋅ ha-1, while from lowland’s catchment outflowed much less nitrogen – 12,7 kg N ⋅ ha-1. Conducted research and analysis clearly show, that the size of nitrogen load outflowed from catchment is determined, to a large extent, the course of weather conditions, particularly amount of rainfall.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 10
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies