Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Janiga, Marek" wg kryterium: Autor


Wyświetlanie 1-13 z 13
Tytuł:
Spektrometria masowa i analiza izotopowa biomarkerów frakcji nasyconej
Mass spectrometry and isotopes analysis of the saturated fraction biomarkers
Autorzy:
Bieleń, Wojciech
Janiga, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2143598.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
spektrometria masowa
analiza izotopowa
biomarkery
hopany
środowisko sedymentacji materii organicznej
mass spectrometry
isotopes analysis
biomarkers
hopanes
sedimentation environment of organic matter
Opis:
Analiza GC-IRMS poszerza i potwierdza (lub nie) interpretację opartą na wynikach z analiz GC-MS. Przykładowo jest bardzo przydatna w określaniu środowiska sedymentacji materii organicznej. Analiza GC-MS biomarkerów i oparte na niej wyniki są wiary- godne, ale dopiero badania GC-IRMS mogą je potwierdzić. W niniejszej pracy próbowano poprzez analizy izotopowe potwierdzić pochodzenie: BNH (28,30-bisnorhopanu) od bakterii chemoautotroficznych, a także wyższych karotenoidów i ich pochodnych od bakterii Chlorobiaceae czy Chromatiaceae. Przeprowadzono badania biomarkerów na aparacie GC-IRMS oraz EA-IRMS. Otrzymane chromatogramy z analiz IRMS porównywano z archiwalnymi analizami GC-MS dla tych samych próbek w celu identyfikacji poszczególnych związków chemicznych. Oprócz dotychczasowej metodyki przygotowania próbek do analiz zastosowano też niestandardową metodę polegającą na rozdziale n-alkanów od węglowodorów rozgałęzionych. Oznaczono na GC-IRMS powtarzalność metody oraz wartości δ13C wybranych biomarkerów z frakcji nasyconej. Stwierdzono, że próbki z małą zawartością biomarkerów nie nadają się do analiz. Z drugiej strony zbyt duże stężenie analitu podanego na chromatograf gazowy powoduje wzrost linii bazowej i gorszy rozdział pików, co również stanowi problem. Wstępnie oznaczono wartości δ13C dla biomarkerów frakcji nasyconej z grupy hopanów: bisnorhopanu (BNH), oleananu, C29 norhopanu, C30 hopanu, moretanu i serii C31–C35 homohopanów oraz dla surowych rop naftowych. Stwierdzono względnie niewielkie różnice w wartości δ13C pomiędzy BNH a hopanami i BNH a surowymi ropami, co sugeruje najprawdopodobniej to samo źródło pochodzenia wszystkich biomarkerów (w tym BNH). Próbowano również oznaczać biomarkery we frakcji aromatycznej metodą GC-IRMS, co jednak się nie udało. Chcąc w przyszłości przeprowadzać takie oznaczenia, należy najprawdopodobniej zastosować specjalną metodykę przygotowania próbek frakcji aromatycznej.
GC-IRMS analysis extends and confirms (or not) the interpretation based on the results of GC-MS analyses. For example, it is very useful in determining the sedimentation environment of organic matter. GC-MS analysis of biomarkers and the results are reliable, but only GC-IRMS studies can confirm it. In this study, the origin of BNH (28,30-bisnorhopane from chemoautotrophic bacteria) and origin of higher carotenoids and their derivatives from Chlorobiaceae or Chromotiaceae bacteria were confirmed through isotopic analyzes. Biomarkers were analyzed using the GC-IRMS and EA-IRMS apparatus. The obtained chromatograms from the IRMS analyses were compared with the archival GC-MS analyses for the same samples in order to identify individual chemical compounds. In addition to the existing methodology of sample preparation for analyses, a non-standard method was also used, consisting in the separation of n-alkanes from branched hydrocarbons. The repeatability of the method was determined on the GC-IRMS and the values of δ13C for selected biomarkers from the saturated fraction were determined. It was found that samples with low biomarker content are not suitable for analysis. On the other hand, too high concentration of the analyte causes an increase of the chromatogram baseline and worse separation of the peaks, which is also a problem. For the crude oils the δ13C values were initially determined for the biomarkers of the saturated fraction from the hopanes group: bisnorhopane (BNH), oleanane, C29 norhopane, C30 hopane, moretane and the C31-C35 homohopane series. Relatively small differences in δ13C values were found between BNH/hopanes and BNH/crude oils, which suggests the same source of origin for all biomarkers (including BNH). Determining biomarkers in the aromatic fraction using the GC-IRMS method was not successful. In the future, a special methodology for preparing samples for carbon isotopic analyses of aromatic fraction will be required.
Źródło:
Nafta-Gaz; 2021, 77, 8; 512-520
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie badań izotopowych do określania pochodzenia wybranych biomarkerów
Application of isotope analyses for determination of the origin of selected biomarkers
Autorzy:
Bieleń, Wojciech
Janiga, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2143240.pdf
Data publikacji:
2022
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
spektrometria masowa
analiza izotopowa
biomarkery
pristan
fitan
substancja źródłowa
mass spectrometry
isotope analysis
biomarkers
pristane
phytane
organic matter
Opis:
Badania izotopowe n-alkanów, pristanu (Pr) oraz fitanu (Ph) przeprowadzono przy pomocy aparatu GC-IRMS. Porównanie wartości δ13C – pristanu do n-C17 oraz fitanu do n-C18, a także zestawienie wartości δ13C pomiędzy pristanem a fitanem w obrębie jednej próbki pomaga zidentyfikować źródło pochodzenia tych izoprenoidów, co było celem pracy. Ta ostatnia informacja uwiarygadnia lub podaje w wątpliwość wskaźnik środowiska sedymentacji – Pr/Ph. Wartości δ13C n-alkanów dla rop naftowych z tego samego złoża: Bóbrka 113, Niepodległość 2, Bandrów wskazują na pochodzenie tych rop od roślin C3 (fotosynteza typu C3) oraz z osadów rzecznych lub/i jeziornych. N-alkany występujące w tych trzech ropach naftowych mogą mieć mieszane źródła i pochodzić zarówno od roślin lądowych, jak i wodnych. Ropa naftowa Łodyna 90K może pochodzić z różnorakich wyższych roślin. Wartości δ13C n-alkanów z próbek ekstraktów bitumicznych Dukla 2A i Dukla 2D są charakterystyczne dla roślin C3. Pristan i fitan w badanych próbkach rop naftowych i w przypadku dwóch próbek ekstraktów bitumicznych Dukla 2A i Dukla 2D mają wartości δ13C niższe niż wartości δ13C dla n-C17 i n-C18, co sugeruje pochodzenie od organizmów heterotroficznych. We wszystkich badanych próbkach rop naftowych (wyjątki: Łodyna 90K, Osobnica 35) wartości δ13C dla Pr i Ph w obrębie pojedynczej próbki świadczą o tym samym materiale źródłowym dla tych izoprenoidów. Ta informacja potwierdza, że wskaźnik Pr/Ph, mówiący o typie środowiska sedymentacji materii organicznej, jest wiarygodny. W dwóch ekstraktach bitumicznych (Dukla 2D i Krosno 8) wartości δ13C dla Pr i Ph są różne, dlatego istnieje duże prawdopodobieństwo odmiennego pochodzenia dla tych dwóch izoprenoidów (należy być ostrożnym co do wiarygodności wskaźnika środowiska sedymentacji Pr/Ph).
Isotope analysis of n-alkanes, pristan (Pr) and phytane (Ph), were carried out on the GC-IRMS apparatus. Comparing the δ13C values of pristan to n-C17, phytane to n-C18 and pristan to phytane within one sample helps to identify the source of these isoprenoids. The latter information legitimises or questions the sedimentation environment index – Pr/Ph. The values of δ13C of n-alkanes for crude oil from one field: Bóbrka 113, Niepodległość 2, Bandrów indicate the origin of C3 plants (photosynthesis type C3) and river and / or lake sediments. The N-alkanes found in these three crude oils could have been sourced by organic matter from terrestrial and aquatic plants. Łodyna 90K crude oil was derived from a variety of higher plants. The δ13C values of n-alkanes for samples Dukla 2A and Dukla 2D bituminous extracts are characteristic for C3 plants. Pristan and phytan in the analyzed crude oil samples and in the case of two samples Dukla 2A and Dukla 2D bituminous extracts have δ13C values lower than the values of n-C17 and n-C18, which suggests their origin from heterotrophic organisms. In all analyzed crude oil samples (exceptions: Łodyna 90K, Osobnica 35) the δ13C values of Pr and Ph within a single sample indicate the same source material for these isoprenoids. This information confirms that the Pr/Ph ratio is reliable. In two bituminous extracts (Dukla 2D and Krosno 8) the δ13C values of Pr and Ph are different, therefore there is a high probability of different origins for these two isoprenoids (the Pr/Ph ratio may be unreliable).
Źródło:
Nafta-Gaz; 2022, 78, 5; 336-342
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of precision of hydrogen isotopic composition determinations by EA-IRMS, GC-IRMS and Py-GC-IRMS
Ocena precyzji oznaczeń składu izotopowego wodoru w układach Py-GC-IRMS, GC-IRMS oraz EA-IRMS
Autorzy:
Janiga, Marek
Kania, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/1834110.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
precision
repeatability
EA-IRMS
GC-IRMS
Py-GC-IRMS
δ2
precyzja
powtarzalność
Opis:
Praca przedstawia wyniki analiz składu izotopowego wodoru produktów pirolizy próbki łupku. Otrzymywane produkty pirolizy to: metan, eten, etan, propylen, propan, 1-buten i n-butan. Wykorzystana aparatura to spektrometr masowy Delta V Advantage firmy Thermo Scientific wraz z chromatografem Trace GC Ultra (kolumna kapilarna HP-PLOT/Q, 30 m) i pirolizerem Pyroprobe 6150 (temperatura pirolizy: 1000°C, izoterma: 30 sekund). Układ połączony jest on-line za pośrednictwem Conflo IV. Metodyka Py-GC-IRMS oznaczeń składu izotopowego wodoru gazowych produktów pirolizy została sprawdzona poprzez ocenę powtarzalności. Próbka łupku była pirolizowana w temperaturach: 500°C, 600°C, 700°C, 800°C, 900°C i 1000°C. Piroliza w 500°C nie pozwala na wydzielenie produktów. Proporcja pomiędzy nienasyconymi i nasyconymi węglowodorami zmienia się i wraz ze wzrostem temperatury zaczynają dominować węglowodory nienasycone. Skład izotopowy poszczególnych par również ulega zmianie, choć stała jest relacja pomiędzy δD nienasyconych i nasyconych węglowodorów. W przypadku wszystkich składników utrzymuje się trend, że przy wyższej temperaturze pirolizy wartości składu izotopowego są również wyższe. Dodatkowo różnice składu izotopowego w temperaturach 900°C i 1000°C są już znikome. Charakter oznaczeń składu izotopowego nie pozwala na określenie granicy oznaczalności, granicy wykrywalności oraz obciążenia metody. Wartości względnych odchyleń standardowych są poniżej pięciu procent jedynie dla metanu, etanu i propylenu. Dodatkowo wykonano testy powtarzalności dla układów EA-IRMS (analizator elementarny połączony z izotopowym spektrometrem masowym) oraz GC-IRMS (nastrzyk próbki bezpośrednio do dozownika chromatografu połączonego z ConFlo IV i spektrometrem). Wykorzystane próbki to węgiel kamienny oraz gaz ziemny. Powtarzalność oznaczeń składu izotopowego wodoru oceniana przy użyciu względnego odchylenia standardowego była najlepsza (najniższa wartość) w przypadku układu GC-IRMS (0,8%), następnie układu Py-GC-IRMS (metan przy naważce 3 mg – 1,2%) i EA-IRMS (2,3%).
Źródło:
Nafta-Gaz; 2020, 76, 9; 569-576
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu przygotowania próbek na uzyskiwane wyniki analiz pirolitycznych
Assessment of the influence of sample preparation on the results of pyrolysis analyses
Autorzy:
Janiga, Marek
Kania, Małgorzata
Wciślak, Agnieszka
Spunda, Karol
Powiązania:
https://bibliotekanauki.pl/articles/2143655.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
piroliza
przygotowanie próbek
mielenie
pirolityczna chromatografia gazowa
pyrolysis
sample preparation
grinding
pyrolysis gas chromatography
Opis:
Celem prac, których wyniki zaprezentowano w artykule, była ocena wpływu sposobu przygotowania próbek na wyniki analiz pirolitycznych: Rock-Eval, Py-GC-FID (chromatografia gazowa z detektorem FID) oraz Py-GC-IRMS (izotopowa spektrometria masowa z chromatografią gazową). Do rozdrobnienia próbek wykorzystuje się zazwyczaj moździerze oraz młyny kulowe. Przygotowano trzy próbki skał o większej zawartości węgla organicznego (łupki) oraz pięć o niższej jego zawartości (w tym dwie próbki z dolomitów i trzy z anhydrytów). Skały zostały zhomogenizowane i podzielone na trzy części. Każda część była mielona w odmienny sposób: ręcznie w moździerzu, w młynie kulowym przez 5 min i w młynie kulowym przez 15 min. W sumie wykonano 24 analizy Rock-Eval, 48 analiz Py-GCFID (dwie temperatury pirolizy, odpowiadające warunkom pirolizy Rock-Eval) oraz 24 analizy Py-GC-IRMS. Sposób zmielenia próbek do analiz Rock-Eval nie odgrywa roli. Wydaje się, że różnice w wynikach wskazują na wpływ błędu analizy oraz charakter próbki. Dla metodyki Py-GC-FID wpływ mielenia na wyniki desorpcji prowadzonej w temperaturze 300°C dla większości badanych próbek można uznać za nieznaczny i pomijalny. W temperaturze 500°C widać pewne korelacje, jednak nie są one tak jednoznaczne, aby odrzucić jeden ze sposobów przygotowania próbek. Dlatego istotne jest, aby wyniki analizować kompleksowo, uwzględniając zarówno skład grupowy, jak też dystrybucję produktów pirolizy. W przypadku analiz składu izotopowego (Py-GC-IRMS) również nie można stwierdzić różnic wartości δ13C związanych z różnym sposobem mielenia próbek. Podsumowując, wszystkie wyniki wskazują na znikomy wpływ sposobu mielenia próbek na wyniki analiz pirolitycznych. Pomimo to istotne jest, aby dla danej serii próbek wykorzystywać tylko jeden sposób przygotowania próbek.
The aim of the work, the results of which are presented in the article, was to evaluate the influence of the method of sample preparation on the results of pyrolytic analyses: RockEval, Py-GC-FID (gas chromatography with FID detector) and Py-GC-IRMS (isotope mass spectrometry with gas chromatography). Mortars and ball mills are most often used to grind the samples. Three rock samples with a higher organic carbon content (shales) and five with a lower organic carbon content (including two samples of dolomites and three of anhydrites) were prepared. The rocks were homogenized and divided into three parts. Each part was ground: by hand in a mortar, in a ball mill for 5 minutes, and in a ball mill for 15 minutes. A total of 24 RockEval analyses, 48 Py-GC-FID analyses (two pyrolysis temperatures corresponding to RockEval pyrolysis conditions) and 24 Py-GC-IRMS analyses were performed. The grinding of the samples for the RockEval analyses is insignificant. The differences in the results seem to indicate the influence of the analysis error and the nature of the sample. For the Py-GC-FID methodology, the influence of milling on the results of desorption carried out at the temperature of 300ºC for most of the tested samples can be considered insignificant and negligible. At the temperature of 500ºC, various types of samples show some correlations, but they are insufficient to reject one of the methods of sample preparation. Therefore, it is important to analyze the results comprehensively, taking into account both the group composition and the distribution of pyrolysis products. In the case of the isotopic composition analyses (Py-GC-IRMS), also no differences in δ13C values related to different types of grinding samples can be found. Summarizing, all the results show a negligible influence of the method of grinding the samples on the results of pyrolysis analyses. Nevertheless, it is important that only one method of sample preparation is used for a separate sample series.
Źródło:
Nafta-Gaz; 2021, 77, 5; 299-312
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Piroliza Py-GC-IRMS – elementy walidacji oznaczania on-line składu izotopowego węgla produktów pirolizy
Pyrolysis Py-GC-IRMS – partial validation of on-line determination of carbon isotope composition
Autorzy:
Janiga, Marek
Kania, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/1835024.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
piroliza
Py-GC-IRMS
walidacja
powtarzalność
liniowość
pyrolysis
PY-GC-IRMS
validation
repeatability
linearity
Opis:
Urządzenia pozwalające poddawać próbkę procesowi pirolizy w precyzyjnie określonych warunkach to pirolizery. Mogą one być łączone z różnymi aparatami, takimi jak chromatografy gazowe (z detektorami FID), spektrometry masowe oraz izotopowe spektrometry masowe. Zestawy GC-IRMS pozwalają na uzyskanie wartości δ13C poszczególnych związków z mieszaniny bez konieczności fizycznego jej rozdziału (rozdział następuje dzięki kolumnie chromatograficznej). Połączenie zestawu GC-IRMS z pirolizerem w układzie on-line pozwala na określanie składu izotopowego produktu pirolizy, a w zasadzie poszczególnych związków chemicznych produktu pirolizy. Praca przedstawia wyniki analiz produktów pirolizy próbki łupku sylurskiego. Otrzymywane produkty pirolizy to: metan, eten, etan, propylen, propan, 1-buten, n-butan oraz ditlenek węgla. Wykorzystana aparatura to spektrometr masowy Delta V Advantage firmy Thermo Scientific wraz z chromatografem Trace GC Ultra (kolumna kapilarna HP-PLOT Q, 30 m) i pirolizerem Pyroprobe 6150 (temperatura pirolizy 1000C, izoterma 30 sekund). Układ połączony on-line za pośrednictwem ConFlo IV. Metodyka Py-GC-IRMS oznaczeń składu izotopowego węgla gazowych produktów pirolizy została skalibrowana i sprawdzona poprzez ocenę powtarzalności i liniowości. Charakter oznaczeń składu izotopowego nie pozwala na określenie: granicy oznaczalności, granicy wykrywalności oraz obciążenia metody. Wszystkie wartości względnych odchyleń standardowych są poniżej pięciu procent (najniższe dla metanu: 0,6%), co jest wynikiem zadowalającym i potwierdzającym, że metoda daje powtarzalne rezultaty. Na podstawie przeprowadzonych badań uznano, że liniowość nie powinna być oceniana dla tej metody, a brak spełnienia kryterium liniowości nie świadczy o gorszych wynikach.
Devices allowing to perform a pyrolysis process under precisely defined conditions are pyrolyzers. They can be combined with various apparatus such as gas chromatographs (with FID detector), mass spectrometers and isotopic mass spectrometers. The GC-IRMS kits allow to obtain δ13C values of individual compounds from the mixture without the necessity of physical separation (the separation takes place in the chromatographic column). The combination of the on-line GC-IRMS kit with the pyrolyzer allows to determine the isotopic composition of the pyrolysis product (the individual chemical compounds of the pyrolysis product). The paper presents the results of analyses of the Silurian shale pyrolysis products. The pyrolysis products obtained are: methane, ethene, ethane, propylene, propane, 1-butene, n-butane and carbon dioxide. The apparatus used is a Thermo Scientific Delta V Advantage mass spectrometer with a Trace GC Ultra chromatograph (HPPLOT/Q capillary column, 30 m) and Pyroprobe 6150 pyrolyzer (pyrolysis temperature 1000°C, isothermal 30 seconds). The Py-GC-IRMS methodology for determining the carbon isotopic composition of pyrolysis gas products has been calibrated and verified by evaluating repeatability and linearity. The nature of isotopic composition determinations does not allow to determine: the limit of quantification, the limit of detection and the method bias. All values of relative standard deviations are below five percent (the lowest for methane 0.6%), which is satisfactory and confirms that the method is reproducible. Linearity should not be evaluated for this method, and the lack of fulfillment of the linearity criterion does not indicate worse results.
Źródło:
Nafta-Gaz; 2019, 75, 5; 247-253
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie języka R do statystycznej analizy oraz analizy skupień dla danych geochemicznych
Use of R programming language for statistical analysis and cluster analysis of geochemical data
Autorzy:
Janiga, Marek
Powiązania:
https://bibliotekanauki.pl/articles/31348311.pdf
Data publikacji:
2023
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
analiza skupień
metoda k-średnich
metoda hierarchiczna
skład gazu ziemnego
cluster analysis
k-means method
hierarchical method
natural gas composition
Opis:
W zagadnieniach geologii naftowej metody statystyczne są szeroko stosowane w petrografii, petrofizyce, geochemii, geomechanice, geofizyce wiertniczej czy sejsmice, a analiza skupień jest istotna w klasyfikacji skał – wyznaczaniu stref o pewnych własnościach, np. macierzystych lub zbiornikowych. Artykuł prezentuje użycie metod statystycznych, w tym metod analizy skupień, w procesach przetwarzania i analizy dużych zbiorów różnorodnych danych geochemicznych. Do analiz statystycznych wykorzystano literaturowe dane z analiz składu chemicznego i izotopowego gazów ziemnych. Wyniki zawierały skład chemiczny gazów ziemnych oraz skład izotopowy. Zastosowano algorytmy tzw. nienadzorowanego uczenia maszynowego do przeprowadzenia analizy skupień. Grupowania było przeprowadzone dwiema metodami: k-średnich oraz hierarchiczną. Do zobrazowania wyników grupowania metodą k-średnich można wykorzystać dwuwymiarowy wykres (funkcja fviz_cluster języka R). Wymiary na wykresie to efekt analizy głównych składowych (PCA) i są one liniową kombinacją cech (kolumn w tabeli). Wynikiem grupowania metodą hierarchiczną jest wykres nazywany dendrogramem. W artykule dodatkowo zaprezentowano wykresy pudełkowe i histogramy oraz macierz korelacji zawierającą współczynniki korelacji Pearsona. Wszystkie prace wykonano z użyciem języka programowania R. Język R, z wykorzystaniem programu RStudio, jest bardzo wygodnym i szybkim narzędziem do statystycznej analizy danych. Przy użyciu tego języka uzyskanie wymienionych powyżej wykresów, tabeli i danych jest szybkie i stosunkowo łatwe. Wyniki analiz składu gazu wydają się mało zróżnicowane. Mimo to dzięki algorytmom k-średnich i hierarchicznym możliwe było pogrupowanie danych geochemicznych na wyraźnie rozdzielne zespoły. Zarówno wartości składu izotopowego, jak i skład chemiczny pozwalają wyznaczyć grupy, które w inny sposób nie byłyby dostrzegalne.
In petroleum geology, statistical methods are widely used in petrography, petrophysics, geochemistry, geomechanics, well log analysis and seismics, and cluster analysis is important for rock classification – determination of zones with certain properties, e.g., source or reservoir. This paper presents the use of the R language for statistical analysis, including cluster analysis, of large sets of diverse geochemical data. Literature data from analyses of chemical and isotopic composition of natural gases were used for statistical analyses. The results included the chemical composition of the natural gases and the isotopic composition. So-called unsupervised machine learning algorithms were used to perform the cluster analysis. Clustering was performed using two methods: k-means and hierarchical. A two-dimensional graph (function fviz_cluster) can be used to illustrate the results of the k-means clustering. The dimensions in the graph are the result of principal component analysis (PCA) and are a linear combination of the features (columns in the table). The result of hierarchical clustering is a graph called a dendrogram. The paper additionally presents box plots and histograms as well as a correlation matrix containing Pearson correlation coefficients. All work was completed using the programming language R. The R language, using the RStudio software, is a very convenient and fast tool for statistical data analysis. Obtaining the above-mentioned graphs, tables and data is quick and relatively easy, using the R language. The results of the analyses of the composition of the gas appear to have little variation. Nevertheless, thanks to k-means and hierarchical algorithms, it was possible to group the geochemical data into clearly separable groups. Both the isotopic composition values and the chemical composition make it possible to delineate groups that would not otherwise be noticeable.
Źródło:
Nafta-Gaz; 2023, 79, 9; 576-583
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakościowo-ilościowa gazów pochodzących z degazacji rdzeni skalnych na tle właściwości petrofizycznych skał kompleksu miedzionośnego południowej części monokliny przedsudeckiej
Qualitative and quantitative evaluation of gases originating from the rock cores degassing against the petrophysical properties of the rocks from copper-bearing complex of the southern part of the Fore-Sudetic Monocline
Autorzy:
Kania, Małgorzata
Janiga, Marek
Powiązania:
https://bibliotekanauki.pl/articles/1835063.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
degazacja
gaz desorbowany
gaz resztkowy
chromatografia gazowa
skład molekularny
właściwości petrofizyczne
seria miedzionośna
LGOM
degassing
desorbed gas
residual gas
gas chromatography
molecular composition
petrophysical properties
copper-bearing series
Legnica-Głogów Copper District (LGOM)
Opis:
Przedmiotem badań były próbki rdzeni pochodzące z utworów miedzionośnych, w celu określenia zależności różnego typu parametrów geochemicznych z wykształceniem litologicznym badanych skał w nawiązaniu do badań petrofizycznych. W związku z tym przeanalizowany został zarówno skład molekularny gazów pod kątem obecności azotu nadmiarowego, helu, wodoru, związków siarki i węglowodorów, jak również dokładna ilość wydzielonego gazu. Badania przeprowadzono na próbkach gazu desorbowanego oraz na próbkach gazu resztkowego i na tej podstawie zostały określone pewne prawidłowości zmian jakościowo-ilościowych, co w konsekwencji pozwala na przewidywanie lokalizacji miejsc o zwiększonej akumulacji dla poszczególnych gazów. Dodatkowo analizie statystycznej poddano wybrane właściwości petrofizyczne skał, z których pozyskano gaz. Na podstawie uzyskanych wyników badań można zaklasyfikować skały takie, jak piaskowiec i dolomit wapnisty, jako typy litologiczne o wysokim potencjale akumulacyjnym dla gazów. Zdecydowanie najwyższa ilość gazu resztkowego uzyskana została z serii piaskowców. Nieco mniejsze ilości gazu wydzieliły się z kolei z próbek dolomitu wapnistego. Jeszcze mniejsze zanotowano dla soli kamiennej, a najniższe dla próbek anhydrytowych. Średnie ilości wydzielonego gazu resztkowego doskonale korelują z właściwościami petrofizycznymi, takimi jak: średnie wartości porowatości całkowitej i otwartej, powierzchnia właściwa oraz przepuszczalność. Na podstawie przeprowadzonej analizy, zaobserwowano duże zróżnicowanie oznaczeń zarówno ilościowojakościowych gazów, jak i właściwości petrofizycznych badanych rdzeni piaskowców i dolomitów wapnistych (gdzie mogą być kumulowane duże ilości gazu, co stanowi zasadnicze zagrożenie dla wyrobisk górniczych). Z kolei dostępne wyniki badań dla próbek anhydrytowych oraz soli kamiennej sugerują, że w analizowanym obszarze (pomimo stosunkowo słabych właściwości kolektorskich skał) pojawiają się jednak warunki do wystąpienia lokalnych pułapek gazu w strefach o podwyższonej porowatości.
The subject of the study were core samples originating from copper-bearing deposits, in order to determine the correlation of different types of geochemical parameters with the lithological variation of the studied rocks in reference to petrophysical investigations. The molecular gas composition for the presence of excess nitrogen, helium, hydrogen, sulfur compounds, and hydrocarbons, as well as the exact amount of evolved gas, were examined. The tests were performed on samples of desorbed gas and on residual gas samples, and on this basis certain regularities of qualitative and quantitative changes were determined, which in turn allows to forecast the location of places with increased accumulation of individual gases. Additionally, the petrophysical properties of the rocks from which the gas was obtained, were subjected to statistical analysis. Based on the obtained research results, rocks such as sandstone and calcareous dolomite can be classified as lithological types with high accumulation capacities for gases. It is clear that the highest amount of residual gas was obtained from a series of sandstones, slightly smaller amounts of gas released from the samples of calcareous dolomite; less were noted for rock salt, and the lowest for anhydrite samples. The average amount of separated residual gas perfectly correlates with the petrophysical properties, such as: mean values of total and open porosity, specific surface area, and permeability. On the basis of the analysis, a large diversity of quantitative and qualitative gas coposition determinations, and the petrophysical properties of the studied sandstone and dolomite cores was observed (where large amounts of gas can be accumulated, which is a major threat to mining excavations). In contrast, the available results for anhydrite and rock salt samples suggest that in the analysed area (despite the relatively poor collector properties of rocks), there are conditions for local gas traps in zones with increased porosity.
Źródło:
Nafta-Gaz; 2019, 75, 6; 314-323
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmienność ilości i składu gazów pochodzących z degazacji rdzeni skalnych w profilu geologicznym otworu z obszaru LGOM
Variability of the amount and composition of gases from the rock cores degassing in the geological profile of the borehole from the LGOM area
Autorzy:
Kania, Małgorzata
Janiga, Marek
Wciślak, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1834131.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
gaz desorbowany
gaz resztkowy
skład molekularny
właściwości petrofizyczne
profil geologiczny
LGOM
desorbed gas
residual gas
molecular composition
petrophysical properties
geological profile
Legnica-Głogów Copper District
Opis:
The main objective of the research was to determine the amount and chemical composition dependence of gases formed during the degassing process of lithologically and petrophysically varied rocks in reference to the geological profile of the borehole. In the case of copper-bearing formations, determining this type of regularity for different types of rocks will make it possible to predict places and directions of gas exhalation. This may contribute, in the future, to maintaining safety in mines. The subject of the research were rock samples from a selected vertical borehole within copper-bearing formation from the southern part of the Fore-Sudetic Monocline. The samples collected for testing represented the following lithological series: red and grey sandstone, dolomite, anhydrite and rock salt. In order to assess the gas-bearing capacity of rocks with different lithofacial structure, the molecular composition and the amount of desorbed and residual gases were tested within selected vertical well. In addition, all core samples were subjected to porosimetric and permeability tests to evaluate the basic petrophysical parameters. Based on the obtained results, it was found that the amount of evaporated residual gas in the whole area of the borehole profile correlates perfectly with petrophysical properties, and more specifically with the values of total porosity. Samples from the sandstone series (both red and grey sandstone) are characterized by the highest total porosity reaching almost 25% and in these rock pores, the largest amounts of residual gas were accumulated and closed. Slightly smaller amounts of gas were separated during the degassing process from the limestone dolomite sample, taken from the depth of 10.00 m with a relatively high total porosity of 7.3%, and even smaller from the depth of 8.35 m. The amount of residual gas for rock salt (Na1) and for anhydrite samples (A1d) remained significantly lower. Large amounts of gas separated from the pore space of cores during the degassing process are associated with a high content of excess nitrogen. The largest amounts were separated from a series of sandstones and from a sample of dolomite, taken from a depth of 10.00 m, i.e. from cores with high total porosity. Additionally, anomalously high values of excess nitrogen in desorbed gas were found in the anhydrite sample, taken from a depth of 52.00 m (with relatively low porosity). The presence of excess nitrogen in this sample can be explained by selective gas adsorption during long-distance migration, as well as the possibility of forming of local gas traps.
Źródło:
Nafta-Gaz; 2020, 76, 1; 3-11
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie skompilowanych badań termicznych w charakterystyce skał macierzystych na przykładzie warstw menilitowych
The use of compiled thermal methods in the characteristics of source rocks on the example of menilite beds
Autorzy:
Labus, Małgorzata
Kierat, Maria
Matyasik, Irena
Spunda, Karol
Kania, Małgorzata
Janiga, Marek
Bieleń, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1834987.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
analiza termiczna
termograwimetria
piroliza
warstwy menilitowe
potencjał generacyjny
thermal analysis
thermogravimetric
pyrolysis
Menilite Beds
generation potential
Opis:
Celem badań było porównanie wyników termicznego rozkładu materii organicznej przy zastosowaniu różnych metod badawczych. Eksperymenty wykonano dla oceny metod interpretacyjnych w charakterystyce potencjału generacyjnego skał macierzystych. Badania przeprowadzono dla próbek łupków menilitowych, uznanych na podstawie wieloletnich badań geochemicznych za dobrej jakości skały macierzyste. Próbki reprezentowały warstwy menilitowe jednostki śląskiej, pobrane z karpackich odsłonięć powierzchniowych. Badania przy zastosowaniu znanych metod: pirolizy Rock-Eval (RE), metody termograwimetrycznej i kalorymetrycznej (TG/DSC) oraz metody pirolizy połączonej z analizą chromatografii gazowej (PY-GC), były wykonywane na tych samych próbkach – zarówno na próbkach skalnych, jak i na wyizolowanym kerogenie. Takie zintegrowane badania nie były dotychczas prowadzone na żadnym materiale skalnym. Zastosowane metody badawcze wykazały znaczną porównywalność otrzymanych wyników. Znaleziono szereg korelacji pomiędzy parametrami z poszczególnych metod, między innymi: ilości węglowodorów wydzielonych podczas PY-GC w przedziale temperatur 300–650°C, a parametrem S2 z RE oraz ubytkiem masy w analizie TG w tym samym przedziale temperatur; wartości S2 próbek skalnych oraz kerogenu z ubytkiem masy w efekcie pirolizy z analizy TG/DSC w temperaturach z zakresu 300–650°C; wartości temperatury maksimum piku S2 (Tpk2) próbek skalnych z temperaturą maksymalnego ubytku masy podczas analizy TG; zawartości węgla rezydualnego (RC) z analizy RE próbek skały i kerogenu z ubytkiem masy w efekcie spalania rezydualnej materii organicznej z analizy TG/DSC w temperaturach z zakresu 650– 1050°C. Ubytek masy, oznaczony podczas analizy termograwimetrycznej, zestawiony z procentowym udziałem poszczególnych frakcji węglowodorowych, w których znaczący udział mają frakcje C9+ potwierdza ropotwórczy charakter substancji organicznej zawartej w warstwach menilitowych. Badania porównawcze metod pirolitycznych: Rock Eval, TG/DSC oraz PY-GC dowiodły kompatybilności wyników uzyskanych wszystkimi metodami. Każda z metod ponadto umożliwia pozyskanie wzajemnie uzupełniających się informacji odnośnie zawartości TOC, stopnia dojrzałości termicznej, jak i typu generowanych węglowodorów oraz innych niewęglowodorowych związków. Przeprowadzone testy oraz wykonane korelacje pokazały celowość stosowania zespołu metod termicznych dla pozyskania kompletnych informacji dotyczących skał macierzystych.
The aim of the research was to compare the results of the thermal decomposition of organic matter using different research methods. Experiments were carried out to assess interpretation methods in the characterization of the generation potential of source rocks. The research was conducted for samples of Menilite shales, recognized on the basis of long-term geochemical studies as good quality source rocks. The samples represented the Menilite Beds of the Silesian Unit, taken from the outcrops in the Carpathians. Research using known methods: Rock-Eval pyrolysis (RE), thermogravimetric and calorimetric methods (TG/DSC), and pyrolysis methods combined with gas chromatography analysis (PY-GC), were performed on the same samples- both on rock samples, as well as isolated kerogen. Such integrated studies have so far not been conducted on any rock material. The applied research methods showed a significant comparability of the results obtained. A number of correlations were found between the parameters from individual methods, including: the amount of hydrocarbons separated during PY-GC in the temperature range of 300–650°C, and the parameter S2 from RE, and mass loss in the TG analysis in the same temperature range; S2 values of rock samples and kerogen with weight loss as a result of pyrolysis from TG/DSC analysis at temperatures in the range of 300–650°C; temperature values of the maximum peak S2 (Tpk2) of rock samples with the maximum mass loss temperature during TG analysis; residual carbon content (RC) from RE analysis of rock and kerogen samples with a mass loss as a result of burning residual organic matter from TG/DSC analysis at temperatures in the range of 650–1050°C. The mass loss determined during thermogravimetric analysis, combined with the percentage share of individual hydrocarbon fractions, in which the C9+ fraction is significant, confirms the high petroleum potential of the organic substance contained in the Menilite Beds. Comparative studies of pyrolytic methods: Rock Eval, TG/DSC and PY-GC have proved the compatibility of the results obtained with all methods. Each of the methods also makes it possible to obtain mutually complementary information relating to the TOC, the degree of thermal maturity and type of generated hydrocarbons and other non-hydrocarbon compounds. The conducted tests and performed correlations showed the usefulness of a set of thermal methods to obtain complete information on source rocks.
Źródło:
Nafta-Gaz; 2019, 75, 2; 67-76
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ewaluacja sweet spotów w polskich formacjach łupkowych w odniesieniu do wybranych parametrów geochemicznych
Evaluation of sweet spots in Polish shale formations in relation to the selected geochemical parameters
Autorzy:
Matyasik, Irena
Janiga, Marek
Spunda, Karol
Powiązania:
https://bibliotekanauki.pl/articles/1834245.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
sweet spot
substancja organiczna
dojrzałość termiczna
gaz z formacji łupkowych
skład izotopowy
organic matter
thermal maturity
shale gas
isotopic composition
Opis:
The article focuses on the geochemical parameters of key importance to the assessment of the hydrocarbon potential of shale formations (the content of organic matter and its thermal maturity and degree of transformation). A comparative analysis of the measurements of gas obtained in the process of core desorption with the analysis of saturations obtained from Rock-Eval pyrolysis was performed. Percentage of retained free hydrocarbons in source levels at the calculated generation was determined. Large discrepancies were observed between the measured reflectance values of vitrinite-like macerals or on zooclasts and the calculated VR values from the Tmax parameter. This means limited applicability and universality of Jarvie formula (Wüst, 2013). A new conversion formula was calculated based on a large sample population. Additionally, the article presents the results of isotopic composition analyzes. Large differences in the δ13C methane, ethane and propane values were stated between the wells. The content of higher hydrocarbons in the gas composition is very high, which may indicate thermogenic origin. Most samples are oil-related gas and mixed gas, one sample is condensate related gas (Peters chart). The gas generation from both wells corresponds to the range of the oil window to the beginning of the gas window (VR from about 0.6 to about 1.35%) (Peters et al., 2005). In addition, using data from degasification experiments (total gas quantities) and pyrolysis parameters obtained from Rock Eval analyzes (Tmax and TOC), it was found that the correlation between the maturity of the source organic matter (determined on the basis of Tmax) and the amounts of gas is small (r = 0.37 for total gas). In contrast, the correlation between the organic carbon content (TOC) and the amounts of gas is high for total gas (r = 0.70).
Źródło:
Nafta-Gaz; 2020, 76, 2; 76-90
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomonitoring studies and supervisory research for the purposes of underground gas storage and currently exploited natural gas deposits
Badania biomonitoringowe oraz kontrolne prace badawcze dla potrzeb podziemnego magazynowania gazu i obecnie eksploatowanych złóż gazu ziemnego
Autorzy:
Turkiewicz, Anna
Janiga, Marek
Powiązania:
https://bibliotekanauki.pl/articles/31348300.pdf
Data publikacji:
2023
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
hydrogen sulphide
microorganisms
deposit waters
biocides
H2S scavenger
permeability
nanomaterials
siarkowodór
mikroorganizmy
wody złożowe
biocydy
pochłaniacz H2S
przepuszczalność
nanomateriały
Opis:
This paper refers to several aspects of research studies supporting the oil and gas industry – in particular underground gas storage (UGS) in depleted deposits and salt caverns – and focuses on questions related to the formation of hydrogen sulphide contamination in reservoir conditions as well as on methods for limiting unfavourable biogenic phenomena. The main problem found at gas storage facilities is the activity of sulphate reducing bacteria (SRB). The elimination or limitation of H2S generation in microbiologically contaminated environments have been the subject of many extensive studies. Biocides, biocorrosion inhibitors and H2S scavengers are widely applied to protect reservoir structure, gas storage infrastructure as well as water-based drilling fluids from the negative effects of bacterial activity. One of the most popular biocidal products, recommended for oil and gas industry are triazine derivatives, laboratory tested in the presented biomonitoring studies. Triazine products prove very effective in biomass reduction and elimination of anaerobic bacteria, especially SRB. Before any industrial operation (based on technology of using biocides), it was necessary to analyse the sulphur compounds in the stored natural gas in different exploitation gas wells of UGS. It was also necessary to investigate the selection of a specific biocidal product and its proper concentration. A concentration that is too low may even stimulate the microbial growth; since the substance is not toxic for microorganisms, they may start to metabolise it. Moreover, the wrong choice of biocides may even generate an economic loss or environmental hazard. Generally, the application of biocides, H2S scavengers and nitrate-based treatment are one of the most effective world strategies to decrease microbiological contamination, which affects various areas of the oil and gas industry. These products have also been successfully applied to control bacterial growth in Polish natural gas wells. The issue of the influence of microorganisms and biomass on the permeability of reservoir rocks was also presented. In addition, the paper refers to biodegradation processes, that take place in the environment of drilling fluids. Also, the issue of choice of biocide/ H2S scavenger preparations for industrial applications is presented. The choice of chemicals includes efficiency tests of nanoparticles in contaminated media.
Artykuł dotyczy kilku aspektów prac badawczych stanowiących wsparcie dla przemysłu nafty i gazu, głównie podziemnego magazynowania gazu w złożach sczerpanych i kawernach solnych. Skoncentrowano się na zagadnieniach związanych z powstawaniem skażeń siarkowodorowych w warunkach złożowych oraz na metodach ograniczania niekorzystnych zjawisk o charakterze biogennym. W obiektach magazynowania gazu duży problem stanowią aktywne bakterie redukujące siarczany z grupy SRB. Eliminacja lub ograniczenie zawartości siarkowodoru w skażonych mikrobiologicznie środowiskach jest przedmiotem wielu prac badawczych. Preparaty takie jak biocydy, inhibitory biokorozji lub neutralizatory H2S są często stosowane do ochrony struktury złożowej, obiektów magazynowych, jak również wodnodyspersyjnych płuczek wiertniczych przed niekorzystnym oddziaływaniem bakterii. Jednym z najbardziej popularnych środków biobójczych stosowanych w przemyśle nafty i gazu są pochodne triazyny, testowane również w ramach omawianych badań biomonitoringowych. Produkty triazynowe są bardzo efektywne w procesach redukcji biomasy oraz eliminacji bakterii beztlenowych, głównie z grupy SRB. Przed każdorazowym zabiegiem przemysłowym (opartym na technologii stosowania biocydów) niezbędne jest przebadanie zawartości związków siarki w magazynowanym gazie, pobranym z różnych odwiertów eksploatacyjnych podziemnego magazynu. Konieczny jest również dobór odpowiednich preparatów oraz wytypowanie optymalnych stężeń preparatów biobójczych. Zbyt niskie stężenie może bowiem stymulować wzrost mikroorganizmów, które są zdolne do wykorzystania danej substancji w procesach metabolicznych. Ponadto niewłaściwy dobór biocydu może powodować straty i wpływać negatywnie na środowisko przyrodnicze. Generalnie stosowanie biocydów, neutralizatorów siarkowodoru i związków azotanowych stanowi jedną z najbardziej skutecznych światowych strategii ograniczenia skażeń mikrobiologicznych w wielu obiektach złożowych. Wymienione wyżej środki chemiczne były również z sukcesem stosowane w polskich odwiertach gazowych. W artykule przedstawiono także problem wpływu mikroorganizmów i biomasy na przepuszczalność skał zbiornikowych. Ponadto nawiązano do zjawisk o charakterze biodegradacyjnym, które mają miejsce w środowisku płuczek wiertniczych. Zaprezentowano problematykę dotyczącą wspomnianego doboru preparatów typu biocyd/H2S scavenger do zastosowań przemysłowych z uwzględnieniem badań efektywności działania nanocząsteczek w skażonych mediach.
Źródło:
Nafta-Gaz; 2023, 79, 8; 503-509
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory research on selection of effective antimicrobial substances and $H_2 S$ scavengers used in drilling fluid technology and underground gas storage
Badania laboratoryjne nad doborem efektywnych substancji biobójczych i neutralizujących siarkowodór dla potrzeb technologii płuczek wiertniczych oraz podziemnego magazynowania gazu
Autorzy:
Turkiewicz, Anna
Janiga, Marek
Rogaliński, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1833983.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
silver nanoparticles
biocide
H2S scavenger
microbial contamination
drilling mud
formation water
oxazolidine
glyoxa
nanocząstki srebra
biocyd
pochłaniacz H2S
skażenie mikrobiologiczne
płuczka wiertnicza
woda złożowa
oksazolidyna
glioksal
Opis:
W artykule omówiono wyniki testów skuteczności działania biocydów dla potrzeb przemysłu naftowego i gazowniczego. Badania zostały przeprowadzone z zastosowaniem zawiesiny cząstek nanosrebra oraz roztworów dwóch produktów biobójczych. Druga część pracy dotyczyła testów skuteczności działania pochłaniaczy siarkowodoru wytworzonych na bazie triazyny. Użyto preparatów rekomendowanych do zastosowania zarówno w technologii płynów wiertniczych, jak i w obiektach podziemnego magazynowania gazu (PMG). Pochodne triazyny (trzy formy izomeryczne) stosowane w przemyśle mają silne własności bakteriobiobójcze w odniesieniu do skażonych płuczek wiertniczych i wód złożowych. Należy zaznaczyć, że procesy biogenne są w dużej mierze odpowiedzialne za biodegradację cieczy wiertniczych. W wyniku tego tracą one swoje własności technologiczne i reologiczne, a także nie spełniają określonych zadań w otworze wiertniczym. Testowane w ramach pracy neutralizatory są produktami chemicznymi, których działanie jest dwutorowe. Mają one jednocześnie zdolność eliminacji bakterii ze skażonego środowiska, jak również pochłaniają wytworzony w nim siarkowodór. Badania pozwoliły na określenie aktywności biobójczej następujących substancji: nanosrebra, następnie nanosrebra w połączeniu z oksazolidyną oraz nanosrebra w połączeniu z glioksalem. Testy laboratoryjne umożliwiły również porównanie efektywności działania poszczególnych neutralizatorów H2S. W badaniach ukierunkowanych na obecność bakterii oraz grzybów określano liczbę JTK (jednostek tworzących kolonie) w próbkach testowych w odniesieniu do liczby mikroorganizmów występujących w próbce kontrolnej (próbka płynu bez substancji biobójczej). Badania te przeprowadzono równolegle w środowisku zainfekowanych płynów, tj. wody złożowej z obiektów PMG (wody zbiorczej – jest to woda pobierana z separatorów) oraz wodno-dyspersyjnej polimerowej płuczki wiertniczej. Omawiane prace badawcze stanowią część kompleksowych badań biomonitoringowych środowisk złożowych, które prowadzone są w celu zwalczenia skażenia mikrobiologicznego i jednocześnie eliminacji zasiarczenia węglowodorów, szczególnie w obiektach magazynowania gazu ziemnego. Badania te przyczyniają się do utrzymania prawidłowej jakości gazu magazynowanego w PMG i tym samym prowadzą do usprawnienia eksploatacji. Wytypowane skuteczne preparaty chemiczne zostaną w przyszłości wykorzystane w przemyśle do zmniejszenia zawartości biogennego siarkowodoru oraz redukcji liczby niekorzystnych mikroorganizmów w środowisku płuczek wiertniczych i wód złożowych.
Źródło:
Nafta-Gaz; 2020, 76, 12; 903--912
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie oznaczeń siarkowodoru z użyciem różnych typów detekcji (FPD, TCD) stosowanych w chromatografii gazowej
Comparison of hydrogen sulfide determination with the use of different types of detection (FPD, TCD) applied in gas chromatography
Autorzy:
Wciślak, Agnieszka
Janiga, Marek
Kania, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2143282.pdf
Data publikacji:
2022
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
związki siarki
siarkowodór
detektor TCD
detektor FPD
elementy walidacyjne
sulfur compounds
hydrogen sulfide
TCD detector
FPD detector
validation elements
Opis:
Odpowiedni dobór detektorów w chromatografii gazowej pozwala na dokładniejsze pomiary analizowanych związków. Wybór detektora zależy od substancji, które chcemy oznaczać, od ich procentowej zawartości w analizowanym gazie, a w niektórych przypadkach również od matrycy próbki, w której dany związek się znajduje. Związki siarki są bardzo częstym przedmiotem badań w laboratoriach geochemicznych. Jak dotąd zdecydowanie najpopularniejszym dostępnym na rynku detektorem do pomiaru ich stężeń jest FPD, używany również w Laboratorium Geochemii Nafty i Gazu INiG – PIB. Jednak w zależności od rodzaju i ilości związków siarki można, po opracowaniu odpowiedniej metodyki, użyć również detektorów FID i TCD. Przy badaniu bardzo niskich stężeń siarkowodoru zgodnie z doniesieniami literaturowymi sugerowane jest użycie detektora SCD, a przy badaniach stężeń wysokich można zastosować miareczkowanie jodometryczne. W ramach badań została wykonana kalibracja oraz przeprowadzono elementy walidacji metodyk oznaczania siarkowodoru na zróżnicowanych poziomach stężeń z użyciem detektorów FPD i TCD. Została sprawdzona specyficzność oraz selektywność zastosowanych metodyk badawczych. Ustalono granicę wykrywalności oraz oznaczalności, obliczono powtarzalność, a także liniowość. Kalibracja oraz wybrane elementy walidacyjne pokazały, jakie są możliwości zastosowanych detektorów, a także dały wiedzę, na jakim poziomie należy oznaczać siarkowodór przy użyciu poszczególnych detektorów powszechnie wykorzystywanych w chromatografii gazowej. Wykonane badania udowodniły, że opracowane metodyki spełniają założone kryteria akceptacji dla wybranych elementów walidacji. W wyniku przeprowadzonych badań stwierdzono, że detektor FPD jest adekwatnym wyborem przy badaniach siarkowodoru w zakresie od 1 ppm do 10 ppm, natomiast TCD jest odpowiedni do oznaczeń wyższych stężeń siarkowodoru, tj. od 0,5% do 5%.
Appropriate selection of detectors in gas chromatography allows for more accurate measurements of the analyzed compounds. The choice of the detector depends on the substances one needs to determine and the percentage share in the analyzed gas, and in some cases also on the sample matrix. Sulfur compounds are a very frequent subject of examination in geochemical laboratories. Until now, the most popular detector commercially available for measuring their concentrations is FPD, also used in the Oil and Gas Geochemistry Laboratory of the Oil and Gas Institute – National Research Institute. However, depending on the type and amount of sulfur compounds, FID and TCD detectors can also be used (when developing an appropriate methodology). In case of low concentrations of hydrogen sulfide, the use of an SCD detector is suggested according to publications, while for high concentrations, iodometric titration can be used. As a part of the research, calibration was performed and elements of validation of the methodologies for the determination of hydrogen sulfide at various concentration levels with the use of FPD and TCD detectors were carried out. The specificity and selectivity of the applied analysis methodologies were checked. The limit of detection and quantification was determined, and the repeatability and linearity for the hydrogen sulfide were calculated. The calibration and selected validation elements showed the capabilities of the detectors used, as well as the knowledge at what level hydrogen sulfide should be determined by individual detectors, commonly used in gas chromatography. This research proved that the developed methodologies meet the assumed acceptance criteria for selected elements of validation. As a result of the conducted research, it was found that the FPD detector is an adequate choice for hydrogen sulfide tests in the range from 1 ppm to 10 ppm, while TCD is suitable for the determination of higher concentrations of hydrogen sulfide, i.e. from 0.5% to 5%.
Źródło:
Nafta-Gaz; 2022, 78, 4; 251-258
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies