Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dulski, R." wg kryterium: Autor


Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania cieplnego oddziaływania promieniowania laserowego na tkanki w trakcie zabiegów stomatologicznych
Study of laser irradiation thermal effect on oral tissues during procedures of dentistry
Autorzy:
Dąbrowski, M.
Dulski, R.
Zaborowski, P.
Żmuda, S.
Powiązania:
https://bibliotekanauki.pl/articles/154110.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
lasery w stomatologii
przyrosty temperatur
termografia
lasers in dentistry
temperature rise
thermography
Opis:
Celem badań było określenie zmian temperatury tkanek w polu zabiegowym podczas różnych zabiegów stomatologicznych z wykorzystaniem lasera. W artykule opisano metody pomiarów opracowane dla poszczególnych zabiegów oraz urządzenia do rejestracji temperatury. W badaniach zastosowano lasery stomatologiczne: laser CO2, laser Nd:YAG i laser Er:YAG. Rejestracje termograficzne wykonano za pomocą dwóch pomiarowych kamer termowizyjnych ThermaCAM SC1000 i ThermaCAM SC3000. Omówiono efekty uzyskane dzięki rejestracji powierzchniowych rozkładów temperatury podczas zabiegów, a w szczególności opracowano zalecenia zwiększające bezpieczeństwo stosowania laserów w stomatologii.
The aim of the study was to determine the temperature changes of tissues in the operative area during several dental treatments involving the use of a laser. The paper presents the measurement methods specially created for that task as well as the devices used to record infrared images. During the research three kinds of laser devices were used: CO2 laser, Nd:YAG laser and Er:YAG laser. Infrared images were recorded by two measurement IR cameras: ThermaCAM SC1000 and ThermaCAM SC3000. The effects obtained by the possibility of real-time recording of surface temperature distribution during treatment were discussed and the recommendations improving the safety of use of laser devices in dental treatment were created.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 9, 9; 48-51
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektów cieplnych w czasie polimeryzacji stomatologicznych materiałów do wypełnień ubytków
Evaluation of thermal effects during polymerization of restorative dental materials
Autorzy:
Dąbrowski, M.
Dulski, R.
Zaborowski, P.
Żmuda, S.
Powiązania:
https://bibliotekanauki.pl/articles/154106.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
lampy polimeryzacyjne
materiały stomatologiczne
termografia
polymerization lamps
dental materials
thermography
Opis:
W artykule przedstawiono wyniki badań dynamiki zmian temperatury podczas polimeryzacji stomatologicznych materiałów do wypełnień z użyciem lamp polimeryzacyjnych. W badaniach wykorzystano powszechnie używane materiały stomatologiczne oraz trzy typy lamp polimeryzacyjnych stosowane w gabinetach dentystycznych: halogenową, ksenonową i lampę z diodami półprzewodnikowymi. W celu porównania własności lamp zmierzono ich parametry promienne. Pomiary temperaturowe wykonano w warunkach in vivo oraz in vitro. Stwierdzono istotne różnice, zarówno w wartości jak i w szybkości przyrostu temperatury polimeryzowanych materiałów w zależności od typu lampy i rodzaju użytego materiału. Na podstawie wyników badań można stwierdzić, że niewłaściwe użycie lampy polimeryzacyjnej stwarza możliwość uszkodzenia tkanek zęba.
In the article the test results are presented, which show the dynamics of temperature change during polymerization of restorative dental materials illuminated by different light sources. Most popular dental materials were examined as well as three different lamps: halogen, xenon and LED-based. The parameters of those lamps were measured in order to compare their characteristics. Temperature measurements were conducted in both in vivo and in vitro conditions. Significant differences were observed in magnitude and temperature increase rate depending on the light source and the type of used material. It was proven that improper choice of illuminating lamp may lead to a damage of dental tissue.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 9, 9; 44-47
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania właściwości promiennych materiałów stosowanych do maskowania okrętów w zakresie podczerwieni
Ships masking in IR band
Autorzy:
Milewski, S.
Dulski, R.
Kastek, M.
Trzaskawka, P.
Powiązania:
https://bibliotekanauki.pl/articles/154518.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
detekcja w podczerwieni
maskowanie statków
detekcja wielowidmowa
IR detection
ship camouflage
vessels detection
multispectral detection
Opis:
Maskowanie okrętów w zakresie podczerwieni jest jednym z podstawowych zadań realizowanych na współczesnym morskim teatrze działań. Efektywnej obrony okrętu wymaga informacji o aktualnym kontraście temperatury okręt - tło. W artykule przedstawiono wyniki pomiarów mocy promieniowania cieplnego wybranych pokryć maskujących jednostek pływających oraz metody modyfikacji sygnatury termicznej okrętów. Analizy teoretyczne poprzedzono badaniami eksperymentalnymi z wykorzystaniem kamer termowizyjnych oraz spektroradiometru.
Masking of ship's thermal signature is one of the key tasks performed in modern naval operations. The main goal of such efforts is to minimize the probability of ship detection and identification, mainly in the aspects of anti-missile defense. In order to obtain effective protection, the actual information on the current thermal contrast between a ship and the background is required. The paper presents the measurement results of the radiant exitance in IR range from various types of camouflage coatings as well as selected methods for modifications of ship's thermal signatures. The assessment of the influence of simulated emissivity change on the radiant exitance emitted from the ship was conducted assuming that the emissivity of the ship equaled to that of the applied coatings. Theoretical analyses were preceded by experimental measurements. The measurements involved the use of measurement-class infrared cameras and LWIR-band Fourier-transform imaging spectroradiometer in order to determine the radiant exitance from several different surface types. The initial experiments were conducted in selected weather conditions and seasons of the year in order to take into account such factors as solar radiation (angle and intensity) and radiation reflected from some chosen elements of the surrounding scenery.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1234-1237
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie rozkładu temperatury w tkankach jamy ustnej oświetlanych promieniowaniem laserowym IR w zabiegach stomatologicznych
Investigation of temperature distribution in oral cavity tissues iradiated of IR laser in procedures of dentistry
Autorzy:
Dąbrowski, M.
Dulski, R.
Zaborowski, P.
Żmuda, S.
Powiązania:
https://bibliotekanauki.pl/articles/160181.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
lasery w stomatologii
wzrost temperatury
termowizja
Opis:
Celem badań było określenie przyrostu temperatury tkanek jamy ustnej podczas laseroterapii. Autorzy sprawdzili zalecane przez producentów metody posługiwania się urządzeniami laserami w wybranych zabiegach stomatologicznych pod kątem ilości ciepła odbieranego przez tkanki w wyniku oddziaływania wiązki promieniowania świetlnego na pole zabiegowe. Pomiary zostały zrealizowane za pomocą kamery termowizyjnej zarówno w warunkach in vivo jak i in vitro. Do badań użyto trzech typów laserów: YAG:Nd, YAG:Er, i CO2. Na podstawie uzyskanych wyników sformułowano zalecenia pozwalające zmniejszyć ryzyko powstania niekorzystnych zmian w tkankach jamy ustnej na skutek oddziaływania promieniowania laserowego.
A main goal of the study was to determine the temperature increase inside oral cavity during laser treatments. Methodology and parameters recommended by equipment manufacturers was tested in chosen operations to determine how they influence on the amount of heat absorbed by oral cavity tissues. Measurements were performed using IR camera. In vitro and in vivo conditions was taking into consideration. Three types of laser was tested: Nd:YAG, Er:YAG, and CO2. On the basis of gathered results of investigations a list of recommendations was formulate which allow to avoid unfavorable changes in the oral cavity resulting from influence of laser radiation.
Źródło:
Prace Instytutu Elektrotechniki; 2010, 245; 19-29
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zmian temperatury światłoutwardzalnych kompozytowych materiałów dentystycznych w trakcie polimeryzacji
Examination of temperature change of composite dentistry materials during polimeryzation
Autorzy:
Dąbrowski, M.
Dulski, R.
Zaborowski, P.
Aluchina, M.
Powiązania:
https://bibliotekanauki.pl/articles/158844.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
wzrost temperatury
polimeryzacja materiałów dentystycznych
termografia
Opis:
Celem badań było określenie przyrostu temperatury nowego materiału światłoutwardzalnego Filtek Siloran w trakcie jego polimeryzacji. Badania wykonano za pomocą kamery termowizyjnej w warunkach in vitro na stanowisku pomiarowym. Głównym zadaniem było określenie wpływu wydłużonego czasu naświetlania nowego materiału kompozytowego na wzrost temperatury w procesie utwardzania. Pomiary wykonano z wykorzystaniem dwóch typów lamp polimeryzacyjnych oraz, w celu porównania wyników, równolegle dla innych powszechnie używanych materiałów do wypełnień. Na podstawie uzyskanych wyników stwierdzono znacznie większe przyrosty temperatury w trakcie polimeryzacji dla nowego materiału.
The aim of the study was to evaluate the temperature rise of a new Filtek Siloran dental material during the polymerization. Measurements were made in vitro using a laboratory stand and a thermal imaging system. The main goal was to elaborate the thermal effects of extended light exposure time required for polymerisation of the new material. During the polymerization with two different lamps it was found that the temperature increased to a level that is much higher than for the traditional dental materials tested together for comparison with the new one.
Źródło:
Prace Instytutu Elektrotechniki; 2008, 234; 97-104
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dalekozasięgowa kamera do monitorowania obiektów infrastruktury krytycznej. Testy zasięgowe
Range Capability Testing of Long Range Surveillance Cameras Used for Protection of Key Installations
Autorzy:
Szustakowski, M.
Życzkowski, M.
Karol, M.
Kastek, M.
Dulski, R.
Bareła, J.
Markowski, P.
Kowalski, M.
Powiązania:
https://bibliotekanauki.pl/articles/373748.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
kamera dalekozasięgowa
system obserwacyjny
test zasięgowy
kamera przeciwmgielna
long range surveillance camera
observation systems
range test
anti-fog camera
Opis:
Cel badań: Głównym celem badań było wyznaczenie i zweryfikowanie efektywnego zasięgu działania systemu kamerowego LongView 2 zarówno w warunkach laboratoryjnych, jak i rzeczywistych. W szczególności dla badanego zestawu kamerowego określenie odległości, na której możliwa jest identyfikacja, rozpoznanie i detekcja obserwowanego celu. Wprowadzenie: Kamery wizyjne, niskiego poziomu oświetlenia oraz przeciwmgielne mają różną zdolność do rejestrowania informacji zewnętrznych, połączenie ich cech może znacznie poprawić zdolność wykrywania intruzów, sytuacji awaryjnych lub zagrażających bezpieczeństwu monitorowanego obiektu. Specjalnie zaprojektowany, na potrzeby nadzoru, wielosensorowy układ detekcyjny kamery tego typu pozwala na obserwację celów na dużym dystansie oraz ich śledzenie za pomocą systemu uchylno-obrotowego z zastosowaniem zoomu optycznego. Dzięki zastosowaniu układu wielosensorowego możliwe jest obserwowanie i śledzenie celu w trudnych warunkach na dużych odległościach, dodatkowo wszystkie elementy systemu zintegrowane są w jednej obudowie, oferując kompaktowość przedstawionego rozwiązania. Dzięki zwartej budowie oraz zastosowaniu wielosensorowego systemu obserwacji opisywany zestaw kamerowy z powodzeniem może być stosowany przez różne służby bezpieczeństwa. Metodyka badań: Artykuł opisuje przeprowadzone badania w celu określenia rzeczywistych parametrów na potrzeby ich ustandaryzowania, ze szczególnym naciskiem na zakres wykrycia, rozpoznania i identyfikacji człowieka. W artykule przedstawione zostały wykorzystane urządzenia pomiarowe, procedury oraz wyniki. Testy przeprowadzone były zgodnie z procedurą pomiarową akredytowanego Laboratorium Badawczego Instytutu Optoelektroniki WAT „Pomiary parametrów urządzeń termowizyjnych”. Wykorzystane metody pomiarowe pozwoliły na określenie parametrów takich jak: minimalna rozróżnialna różnica temperatur (MRTD), minimalny rozróżnialny kontrast (MRC) oraz funkcja przenoszenia modulacji (MTF). Przeprowadzone badania poligonowe miały na celu weryfikację działania i użyteczności testowanych kamer w rzeczywistych warunkach pracy oraz porównanie wartości parametrów zmierzonych podczas testów laboratoryjnych z obiektywną oceną operatora kamery. Wyniki: Przeprowadzone badania laboratoryjne i poligonowe pozwoliły na określenie zasięgów skutecznego działania kamer systemu LongView 2 do zastosowań w systemach ochrony obiektów rozległych. Wnioski: Przeprowadzone badania i testy potwierdziły skuteczność działania systemu kamer LongView 2 zarówno przy zastosowaniach do identyfikacji zagrożeń, jak i dalekozasięgowej obserwacji obiektów morskich i lądowych.
Aim: The main purpose of this research was to determine and verify the effective range of Long View 2 camera systems in laboratory and practical conditions. Particularly, the authors endeavoured to determine the distance at which the tested camera could identify, recognize and detect an observed target. Introduction: Low light vision and fog video cameras have different abilities to record external information. Therefore, the linking of their individual features may significantly improve the ability to detect intruders, emergency incidents or situations which endanger the safety of a target under surveillance. Specially designed for surveillance, multi-sensor detection camera systems facilitate observation at a long distance and tracking of targets with the aid of a pan-tilt mechanism incorporating an optical zoom. All system components are integrated in a single compact housing. The compact design and multi-sensor components allow for the equipment to be used successfully by various security services. Methodology: This article describes a research process used to determine practical application parameter standards, with a special focus on the range for detection, recognition and identification of humans. The article identifies measuring equipment used, procedures and results. Tests were carried out in accordance with established procedures “Parameter measurements of infrared devices”, established by the accredited Testing Laboratory of the Institute of Optoelectronics, Military University of Technology (MUT). The process applied in the research allowed for the determination of parameters such as; the minimum resolvable temperature difference (MRTD), the minimum resolvable contrast (MRC) and the modulation transfer function (MTF). Field tests were performed to verify the capability and usability of cameras in working conditions. Additionally, results obtained during laboratory tests were compared with an objective assessment by the camera operator. Results: Laboratory research and field tests facilitated the determination of an effective range for the operation of the Long View 2 camera system, intended for use in security systems covering a large expanse. Conclusions: Conducted research and tests have confirmed the effectiveness of the Long View 2 camera system for use in identification of threats and long-range observation of offshore and onshore targets
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 4; 103-111
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electro-optical passive sniper detection conception and system overview
Pasywne wykrywanie strzelca wyborowego : koncepcja i optoelektroniczne systemy wykrywania
Autorzy:
Kastek, M.
Dulski, R.
Trzaskawka, P.
Powiązania:
https://bibliotekanauki.pl/articles/210046.pdf
Data publikacji:
2010
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
detekcja
termowizja
analiza obrazu
systemy optoelektroniczne
sniper detection
muzzle flash detection
infrared detection
Opis:
The paper presents modern sensor systems for sniper detection. Among such systems there are active and passive optoelectronic devices. Its primary advantage is the possibility of early recognition of the threat, before the sniper is able to take the shot. Presented passive systems employ thermal cameras and advanced image processing algorithms to distinguish the sniper and muzzle blast signatures. Active systems, in turn, rely on the detection of laser radiation, retro reflected from pointed optics (optical sights and observation scopes). The paper presents basic technical and tactical characteristics of sniper detection devices, both standalone and included in multi-sensor detection systems.
W artykule przedstawiono współczesne systemy detekcyjne przeznaczone do wykrywania snajpera. Wśród systemów tego typu, wprowadzanych na uzbrojenie wielu armii istotną rolę pełnią pasywne i aktywne systemy optoelektroniczne. Ich zaletą jest możliwość wczesnej detekcji zagrożenia, zwłaszcza przed oddaniem strzału przez snajpera. Przedstawione systemy pasywne wykorzystują kamery termowizyjne i zaawansowane metody analizy obrazu w celu wykrycia sygnatur snajpera i strzału z broni palnej. Systemy aktywne wykorzystują z kolei promieniowanie laserowe w celu wykrycia optycznych przyrządów celowniczych i obserwacyjnych.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2010, 59, 3; 277-293
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kamera termowizyjna z niechłodzoną matrycą detektorów PbSe o dużej prędkości rejestracji
Fast thermal camera with uncooled PbSe focal plane array
Autorzy:
Trzaskawka, P.
Dulski, R.
Kastek, M.
Powiązania:
https://bibliotekanauki.pl/articles/154571.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kamera termowizyjna
detektor PbSe
wykrywanie strzałów
thermal camera
PbSe detector
gunshot detection
Opis:
W artykule opisano kamerę z niechłodzonym matrycowym detektorem PbSe o rozdzielczości 32x32 piksele. Opisano konstrukcję kamery opracowanej przez New Infrared Technologies wyposażonej w matrycę detektorów wykonaną w technologii VPD (ang. Vapour Phase Deposition), pracującą w zakresie spektralnym 3 - 5 žm. Kamera ta jest w stanie rejestrować obrazy z prędkością przekraczającą 1500 klatek na sekundę, dzięki czemu nadaje się szczególnie do rejestracji wysokotemperaturowych, szybko-zmiennych procesów i zjawisk. Przedstawiono możliwości dedykowanego oprogramowania oraz przykłady zastosowań, takich jak rejestracja strzałów z ręcznej broni palnej.
The paper presents a fast thermal camera with PbSe uncooled focal plane array. The array detector is manufactured using Vapour Phase Deposition (VPD) process, which makes it possible to easily integrate the array with silicon CMOS read-out circuits. The most important features of the PbSe array (shown in Fig. 1) are fast data acquisition rate (up to 1600 fps) and room temperature operation. The construction of MATRIX 1024 camera, manufactured by NIT Ltd. is described, including universal camera core module 2M-32-100 (Fig. 2). The control and data analysis software bundle which offers the possibility to perform 2-point NUC and offset correction is also presented (Figs. 3, 4). The camera was applied to record some fast, high temperature processes, such as gunshots. Measurements included laboratory session for camera calibration against a precise blackbody (Fig. 5) and field tests, where the real shots from selected weapons were recorded. The theoretical, calculated shot detection ranges were confirmed during the field tests, performed according to the scenario schematically shown in Fig. 6. The fast camera image acquisition rate made it possible to record several frames during a single shot. Sample results are presented in Fig. 7. The current state of PbSe technology, mainly the low resolution of arrays (32 x 32 pixels) limits the usage of the tested camera to some specific applications, like monitoring of fast, high-temperature processes. A wider area of applications is expected, when higher resolution arrays become available.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 10, 10; 1123-1126
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method of object tracking implemented in multisensor security system
Metoda śledzenia obiektów zaimplementowana w wieloczujnikowym systemie ochrony
Autorzy:
Bieszczad, G.
Szustakowski, M.
Dulski, R.
Ciurapiński, W.
Życzkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/235747.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
bezpieczeństwo baz wojskowych
wieloczujnikowy system ochrony
security of military bases
multi protection system
Opis:
Recent military conflicts revealed the need to increase security for military convoys and bases. More and more sophisticated techniques of carnouflage and warfare are utilized by for example terrorists. This situation demands a development of sensor systems for automatic detection and tracking of threats. In article the concept of multi-sensor system for detection and tracking objects is presented. System is built of radar, visual and thermal camera. Radar is used for wide area monitoring, detection and preliminary localization. Visual and thermal camera is used for precise localization and tracking of objects being potential threat. In article the principles of system operation are described. In article the visual object tracking algorithm used in the system is described. The security system described in this paper can be used as an early warning system for mobile units or temporary bases.
Doświadczenia z ostatnich konfliktów zbrojnych ujawniły potrzebę zwiększenia bezpieczeństwa konwojów oraz baz wojskowych. Coraz bardziej wysublimowane techniki kamuflażu oraz walki stosowane na przykiad przez terrorystów wymagają rozwoju systemów wieloczujnikowych do detekcji oraz lokalizacji zagrożenia. W artykule przedstawiono koncepcję wieloczujnikowego systemu do wykrywania i śledzenia obiektów składającego się z radaru, kamery rejestrującej obraz w świetle widzialnym oraz kamery termowizyjnej rejestrującej promieniowanie podczerwone. Zastosowanie radaru umożliwia detekcję zagrożenia oraz wstępną lokalizacje, natomiast czujniki w postaci kamery dziennej i kamery termowizyjnej zapewniających obserwację obiektu oraz jego śledzenie. W artykule przedstawiono zasadę działania systemu, oraz omówiono algorytm do śledzenia obiektów na obrazie zastosowany w urządzeniu. Wieloczujnikowy systemu ochrony zrealizowany według zaproponowanej koncepcji może stanowić swoisty system wczesnego ostrzegania przed zagrożeniem.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 110; 57-64
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda komputerowej symulacji sceny termalnej
Method of a computer simulation of a thermal scene
Autorzy:
Dulski, R.
Piątkowski, T.
Sosnowski, M.
Dąbrowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/154122.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
modelowanie sceny termalnej
sygnatury termalne
symulacje komputerowe
thermal scene modeling
thermal signature
computer simulations
Opis:
W artykule opisano metodę komputerowej symulacji i analizy sceny termalnej. Modelowanie układu detekcji, obserwowanego obiektu oraz otoczenia umożliwia wyznaczenie parametrów istotnych z punktu widzenia skuteczności detekcji obiektu w podczerwieni oraz zaprezentowano przykładowe termogramy, będące wynikiem przeprowadzonych symulacji. Wykorzystanie opisanej metody umożliwia uzyskanie odpowiedzi na wiele pytań konstrukcyjnych już na etapie projektowania urządzenia termodetekcyjnego oraz daje możliwość ograniczenia do minimum drogich i czasochłonnych badań eksperymentalnych na rzeczywistych obiektach.
The paper presents a method for simulation and analysis of a thermal scene. The simulation of detection system and observed object together with surrounding scenery makes it possible to determine several parameters crucial in terms of IR detection efficiency. It answers many questions at the early stage of design of a thermodetection device. Utilization of the method described here also reduces the needs for expensive and time-consuming field tests on real objects.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 9, 9; 9-11
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multisensor system for the protection abovewater of seaport
Autorzy:
Kastek, M.
Życzkowski, M.
Szustakowski, M.
Trzaskawka, P.
Ciurapiński, W.
Dulski, R.
Powiązania:
https://bibliotekanauki.pl/articles/331780.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
There are many separated infrastructural objects within a harbor area that may be considered „critical”, such as gas and oil terminals or anchored naval vessels. Those objects require special protection, including security systems capable of monitoring both surface and underwater areas, because an intrusion into the protected area may be attempted using small surface vehicles (boats, kayaks, rafts, floating devices with weapons and explosives) as well as underwater ones (manned or unmanned submarines, scuba divers). The paper will present the concept of multisensor security system for a harbor protection, capable of complex monitoring of selected critical objects within the protected area. The proposed system consists of a command centre and several different sensors deployed in key areas, providing effective protection from land and sea, with special attention focused on the monitoring of underwater zone. The protection of surface area is based on medium-range radar and LLTV and infrared cameras.
Źródło:
Hydroacoustics; 2013, 16; 101-112
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optoelectronics systems for sniper detection
Optoelektroniczne systemy wykrywania strzelca wyborowego
Autorzy:
Kastek, M.
Dulski, R.
Trzaskawka, P.
Zygmunt, M.
Wojtanowski, J.
Kaszczuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/236092.pdf
Data publikacji:
2009
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
systemy detekcyjne
systemy optoelektryczne
systems detection
optoelectronics systems
Opis:
The paper presents modern sensor systems for sniper detection. Among such systems there are active and passive opto-electronic devices. Its primary advantage is the possibility to early recognize the threat, before the sniper is able to take the shot. Presented passive systems employ thermal cameras and advanced image processing algorithms to distinguish the sniper and muzzle blast signatures. Active systems, in turn, rely on the detection of laser radiation, retro reflected from pointed optics (optical sights and observation scopes). The paper presents basic technical and tactical characteristics of sniper detection devices, both standalone and included in multi-sensor detection systems.
W artykule przedstawiono współczesne systemy detekcyjne przeznaczone do wykrywania snajpera. Wśród systemów tego typu, wprowadzanych na uzbrojenie wielu armii istotną rolę pełnia pasywne i aktywne systemy optoelektroniczne. Ich zaletą jest możliwość wczesnej detekcji zagrożenia, zwłaszcza przed oddaniem strzału przez snajpera. Przedstawione systemy pasywne wykorzystują kamery termowizyjne i zaawansowane metody analizy obrazu w celu wykrycia sygnatur snajpera i strzału z broni palnej. Systemy aktywne wykorzystują z kolei promieniowanie laserowe w celu wykrycia optycznych przyrządów celowniczych i obserwacyjnych. W artykule przedstawiono charakterystyki techniczne i taktyczne szeregu urządzeń optoelektronicznych przeznaczonych do wykrywania snajpera, pracujących jako samodzielne urządzenia bądź jako elementy składowe \\ieloczujnikowych systemów detekcyjnych.
Źródło:
Problemy Techniki Uzbrojenia; 2009, R. 38, z. 109; 23-30
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies