Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "drinking water" wg kryterium: Temat


Tytuł:
Analiza czynników wpływających na zmiany składu chemicznego wód przeznaczonych do spożycia
Analysis of factors influencing changes of drinking water chemical composition
Autorzy:
Wątor, K.
Kmiecik, E.
Postawa, A.
Powiązania:
https://bibliotekanauki.pl/articles/2075619.pdf
Data publikacji:
2017
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
woda pitna
analiza czynników
drinking water
factor analysis
Opis:
Drinking water samples were collected from 501 points in five cities located in south Poland - Kraków, Myszków, Jaworzno, Racibórz and Kamienna Góra, using the random daytime sam-pling method (RDT). All samples were collected by trained samplers from randomly chosen buildings, at random hours and without prior flushing. Analysis of chemical composition of water samples was conducted at the certified Hydrogeochemical Laboratory of AGH - University of Science and Technology in Kraków. Concentrations of selected trace elements (As, Cr, Zn, Al, Cd, Mn, Cu, Ni, Pb, Fe) and major ions (Na, Ca, Mg, K, Cl-, SO42-, HCO3¯) were measured. The principal component analysis was performed. The dimension reduction was made on the basis of major ions. Two principal components were used: the first one was dependent on the concentration of Cľ , SO42-, NaandK, and the second one included the concentration of Mg, Ca and HCO-. The analysis indicated a diversity of the results in virtue of sampling site. Three groups of results were clearly indicated: the first one represented water samples from Kraków and Kamienna Góra, the second one - samples from Myszków and Racibórz, and the third group was were the samples collected in Jaworzno. This diversity results from the type of water intake (groundwater and surface water), manner of water water supply systems.
Źródło:
Przegląd Geologiczny; 2017, 65, 11/2; 1388--1392
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bateria zbiorników wyrównawczych na wodę pitną w Arłamowie - pięciogwiazdkowa technologia
Autorzy:
Krasuska, E.
Powiązania:
https://bibliotekanauki.pl/articles/363852.pdf
Data publikacji:
2012
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
instalacja
woda pitna
zbiornik wyrównawczy
drinking water
installation
reservoir
Opis:
Nagrodzona Grand Prix na konferencji INFRAEKO 2012 bateria zbiorników wyrównawczych Weho produkcji KWH Pipe Poland Sp. z o.o. już w przyszłym roku będzie służyła gościom nowo budowanego Wschodnioeuropejskiego Centrum Kongresowo-Sportowego w Arłamowie.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2012, 5; 36-38
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekty systemów do produkcji wody pitnej z wody morskiej z zastosowaniem geotermii
Project of system for fresh water production using geothermal energy
Autorzy:
Pawlikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/183476.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
woda morska
woda pitna
energia geotermalna
sea water
drinking water
geothermal energy
Opis:
Modern technology of fresh water production using sea water and geothermal energy is presented. Two methods are described: 1- technology with the use of geothermal springs (natural) or hot water obtained from boreholes as heating medium for distillation of sea water, 2- technology allows the production of drinking water from sea water by means of the energy obtained from water heated by hot ground.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 227-231
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjna technologia uzdatniania wody dla gospodarstw z produkcją zwierzęcą
Innovative technology of water treatment for the animal farms
Autorzy:
Eymontt, A.
Wierzbicki, K.
Powiązania:
https://bibliotekanauki.pl/articles/239180.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bakteriofagi
chitozan
woda pitna
uzdatnianie wody
bacteriophages
chitosan
drinking water
water treatment
Opis:
Przeprowadzone badania właściwości bakteriofagów i chitozanu wskazują na możliwość ich zastosowania do uzdatniania wody pitnej, szczególnie pod względem mikrobiologicznym. Na wsiach polskich buduje się coraz więcej sieci wodociągowych o długościach dochodzących do kilkunastu kilometrów, co zwiększa możliwość skażenia wody doprowadzanej do gospodarstw na skutek awarii lub osadzania się bakterii na ściankach rurociągów. Wobec powyższego konieczne jest opracowanie nowych, tanich i skutecznych technologii uzdatniania wody, przede wszystkim pod względem bakteriologicznym. W Laboratorium Bakteriofagowego Instytutu Immunologii i Terapii Doświadczalnej PAN, w Instytucie Technologiczno-Przyrodniczym (Oddział w Warszawie), na Politechnice Śląskiej oraz w innych ośrodkach naukowych podjęto prace w celu przebadania i wdrożenia układów fagowo-chitozanowych, skutecznie oczyszczających wodę ze skażeń bakteryjnych i chemiczno-fizycznych. Celem pracy jest przeprowadzenie analizy, czy badana technologia może mieć zastosowanie do uzdatniania wody zarówno dla ludzi, jak i dla zwierząt.
The results of recent studies on characteristics of bacteriophages and chitosan indicate their utility to purification of drinking water, especially in microbiological aspect. Actually, in the country regions of Poland there are built many water-pipe networks of the length up to several kilometers. Such a distance increases contamination risk for the water supplied to farms, as resulted from piping failures, cracking the pipes or settling bacteria on the pipe walls. In such a situation it is necessary to elaborate new, inexpensive and effective technnologies of water treatment, first of all in bacteriological way. In the Bacteriophage Laboratory of Immunology and Experimental Therapy Institute, Polish Academy of Sciences, in the Institute of Technology and Life Sciences (Branch in Warsaw), as well as in Silesian Technological University and some other research centres, the studies have been undertaken in order to investigate and implement the bacteriophage - chitosan system for effective biological treatment and chemical purification of drinking water. The aim of research is to analyse, whether the investigated technology may be applied to treatment of water supplied for both, human and animal consumption.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 1, 1; 105-113
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania fizyczno-chemiczne wód mineralnych Krynicy-Zdrój. Cz. 1: Badania fizyczne
Autorzy:
Bodora, S.
Powiązania:
https://bibliotekanauki.pl/articles/274540.pdf
Data publikacji:
2011
Wydawca:
Roble
Tematy:
woda mineralna
woda pitna
wody podziemne
Krynica-Zdrój
mineral water
drinking water
groundwater
Źródło:
LAB Laboratoria, Aparatura, Badania; 2011, 16, 5; 36-40
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania fizyczno-chemiczne wód mineralnych Krynicy-Zdrój. Cz. 2: Badania chemiczne
Autorzy:
Bodora, S.
Powiązania:
https://bibliotekanauki.pl/articles/274072.pdf
Data publikacji:
2011
Wydawca:
Roble
Tematy:
woda mineralna
woda pitna
wody podziemne
Krynica-Zdrój
mineral water
drinking water
groundwater
Źródło:
LAB Laboratoria, Aparatura, Badania; 2011, 16, 6; 28-30
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obecność farmaceutyków w wodach powierzchniowych i przeznaczonych do spożycia
Pharmaceuticals in surface and drinking water
Autorzy:
Szymonik, A.
Lach, J.
Powiązania:
https://bibliotekanauki.pl/articles/127174.pdf
Data publikacji:
2013
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
farmaceutyki
wody powierzchniowe
woda przeznaczona do spożycia
toksyczność
pharmaceuticals
surface water
drinking water
toxicity
Opis:
W pracy przedstawiono stężenia wybranych farmaceutyków w ściekach nieoczyszczonych i po oczyszczeniu, wodach powierzchniowych i wodach przeznaczonych do spożycia w Polsce oraz na świecie. Opisano również wpływ farmaceutyków na człowieka i organizmy wodne. Najczęściej identyfikowanymi lekami w ściekach są: beta-blokery (atenolol, propanolol, metoprolol), niesteroidowe leki przeciwzapalne (diklofenak, naproksen, ketoprofen), hormony płciowe (naturalne: estron, 17 b-estradiol, estriol i syntetyczne: etinyloestradiol), karbamazepina - lek przeciwpadaczkowy, regulatory gospodarki lipidowej - fibraty (kwas klofibrowy, gemfibrozil, bezafibrat). Dane leki są trudno usuwalne w nawet rozbudowanych procesach oczyszczania ścieków. Karbamazepina ulega eliminacji w 10%, diklofenak od 21 do 40%, naproksen w 50-80%, metoprolol (beta-bloker) do 25%, a propanolol (najbardziej lipofilowy beta-bloker) jest prawie nieusuwalny. Obecność leków w wodach powierzchniowych jest problemem globalnym.
The article presents the analysis of the concentrations of selected pharmaceuticals in non-treated and treated wastewater, surface water and drinking water in Poland and around the world. Also, the effects of pharmaceuticals on human beings and aqueous organisms were discussed. Among pharmaceuticals the most frequently identified in wastewater are: beta-blockers (ie atenolol, propanolol, metaprolol), non steroidal anti inflammatory drugs (ie diclofenac, naproxen, ketoprofen), estogens (natural: estrone, 17 b-estradiol, estriol and synthetic: ethinylestradiol), carbamazepine - an anticonvulsant drug, and lipid regulators - fibrates (ie clofibric acid, gemfibrozil, bezafibrate). Some of these pharmaceuticals are difficult to remove even through advanced processes of wastewater treatment. Carbamazepine can be removed by 10%, diclofenac can be removed by 21 up to 40%, naproxen can be removed by 50-80%, metoprolol (that belongs to the group of beta-blockers) can be removed by 25%, and propanolol (the most lipophilic beta-blocker) is almost non removable. The presence of pharmaceuticals in surface water is now considered a global issue.
Źródło:
Proceedings of ECOpole; 2013, 7, 2; 735-743
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe przepisy dotyczące jakości wody do picia w Federacji Rosyjskiej i na Ukrainie
New drinking water quality regulations in Russia and Ukraine
Autorzy:
Roman, M.
Powiązania:
https://bibliotekanauki.pl/articles/236578.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda do picia
przepisy sanitarne
standardy europejskie
drinking water regulations
EU standards
Opis:
Scharakteryzowano nowe uregulowania prawne dotyczące jakości wody do picia w Federacji Rosyjskiej (SanPiN) i na Ukrainie (DSanPin). Analizę porównawczą oparto na standardach jakościowych stosowanych w tym zakresie w Unii Europejskiej (Council Directive 98/83/EC). Wykazano, że standardy dotyczące jakości wody do picia zawarte w przepisach rosyjskich i ukraińskich częściowo są zgodne z unormowaniami podanymi w dyrektywie UE, a częściowo różnią się od nich tak wartością jak i liczbą normowanych parametrów. W przepisach rosyjskich przyjęto zasadę, zgodnie z którą suma ilorazów stężeń substancji toksycznych do ich normatywnych wartości nie może przekraczać jedności, co oznacza istotne zaostrzenie wymagań w stosunku do zawartości tych substancji w wodzie. Ponadto w przepisach rosyjskich i ukraińskich zakres unormowań parametrów mikrobiologicznych jest znacznie szerszy niż w dyrektywie UE - w przepisach rosyjskich i ukraińskich uwzględnia się nawet parametry parazytologiczne wody. Stąd też specyficzne podejścia w przepisach rosyjskich i ukraińskich do normowania jakości wody do picia zasługują na rozważenie pod kątem ich wykorzystania w przyszłych modyfikacjach przepisów polskich czy też przepisów w innych krajach europejskich.
Comparative analysis has been made of the new potable water quality regulations recently issued in Russia (SanPiN) and Ukraine (DSanPin), which have been related to relevant EU standards (Council Directive 98/83/EC). The comparisons have revealed the following: Both SanPiN and DsanPin partly comply with the EU recommendations, but they differ in the admissible values and in the number of the parameters which are to be analyzed. The Russian regulations make use of the principle that the sum of the quotients of the toxic substance concentrations related to the standard values must not be greater than unity. And this means that the demands made on the content of toxic substances in water have increased substantially. Moreover, compared to the Council Directive 98/83/EC, the Russian and Ukrainian regulations include a wider range of standardized microbiological parameters, consideration being also focused on parasitological parameters. In view of potential modifications to the potable water quality standards in Poland or elsewhere in Europe, it seems advisable to take a close look at the specific approach to the water quality problem expressed in SanPiN and DsanPin.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 2, 2; 3-8
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy filtrów przelewowych
Evaluation of the operation effectiveness of overflow filters
Autorzy:
Puszczało, Ewa
Kudlek, Edyta
Marszałek, Anna
Powiązania:
https://bibliotekanauki.pl/articles/125746.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
woda pitna
dzbanek filtracyjny
filtr przelewowy
drinking water
filter jug
overflow filter
Opis:
Celem badań była ocena skuteczności pracy filtrów przelewowych. W dzbanku filtracyjnym o objętości 2,0 dm3 codziennie przez okres jednego miesiąca filtrowano 5 dm3 wody wodociągowej. Próbki do badań pobierano co 3 dni. Analizie poddano także próbki wody bezpośrednio po przepłukaniu filtra oraz po pierwszej i drugiej filtracji od założenia nowego wkładu. Skuteczność pracy filtrów została oceniona na podstawie pomiaru parametrów fizykochemicznych, tj. stopnia obniżenia twardości wody, pH, zawartość chlorków, absorbancji, barwy, ogólnego węgla organicznego oraz eliminacji zanieczyszczeń z grupy Emerging Pollutants. Ponadto wykonana została analiza toksykologiczna próbek po filtracji, która wykazała ich nietoksyczny charakter na każdym etapie prowadzenia badań. Na podstawie przeprowadzonych badań można stwierdzić, że po dwóch tygodniach pracy filtra może on nie spełniać już swojej funkcji, natomiast, biorąc pod uwagę możliwość występowania w sieci wodociągowej różnych zanieczyszczeń, stosowanie filtrów wydaje się być niezbędne.
The aim of the study was to evaluate the effectiveness of overflow filters. The tests were carried out in a 2.0 dm3 filter jug. Each filter was tested for a period of 1 months. 5 dm3 of tap water were filtered every day. Samples for analyzes were taken every 3 days. The water samples were collected immediately after the filter was rinsed. Water samples taken after the first and second filtration through a new cartridge (such water is according to filter jugs producers not suitable for drinking) were also analyzed. The effectiveness of the tested filters was evaluated based on the monitoring of physicochemical parameters such as: water hardness, pH, chloride content, absorbance, color, total organic carbon and also by the elimination of pollutants from the Emerging Pollutants group. In addition, a toxicological analysis of the samples after filtration was carried out. A non-toxic nature of each sample at every stage of the test has been proved. Based on the conducted tests, it can be concluded that after two weeks of filter operation, it may no longer fulfill its function. However, taking into account the possibility of occurrence of even pollution in the water supply network, the use of filters seems to be necessary.
Źródło:
Proceedings of ECOpole; 2019, 13, 1-2; 155-162
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie bakterii antybiotykoopornych w wodzie przeznaczonej do spożycia przez ludzi
Antibiotic resistant bacteria in drinking water
Autorzy:
Łebkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236572.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda
woda pitna
kąpielisko
woda butelkowana
bakteria lekoodporna
drinking water
water
bottled water
drug resistant bacteria
Opis:
Omówiono występowanie bakterii lekoopornych w środowisku wodnym, ze szczególnym uwzględnieniem wody przeznaczonej do spożycia przez ludzi. Podano sposoby przenoszenia cechy oporności z komórek (dawców R+) na komórki wrażliwe biorców i scharakteryzowano pojecie oporności mikroorganizmów na antybiotyki. Opisano mechanizmy indywidualnej oporności bakterii na środki dezynfekcyjne, jak również oporności mikroorganizmów zasiedlających tzw. biofilm w przewodach wodociągowych. Podano przykłady lekooporności bakterii w warunkach dezynfekcji wody. Przedstawiono informacje związane z występowaniem bakterii opornych na leki w wodach butelkowanych i w wodach przeznaczonych do rekreacji. Wykazano, że ze względu na wzrastające zużycie leków w terapii ludzi i w leczeniu zwierząt zwiększa się zawartość bakterii antybiotykoopornych w ściekach, w wodach powierzchniowych i w wodzie przeznaczonej do spożycia. Zjawiska te wymagają podjęcia działań w kierunku odpowiedniego stosowania antybiotyków, ograniczenia liczby mikroorganizmów w ściekach i - w konsekwencji - w wodach ujmowanych do celów wodociągowych, a także optymalizacji technologii oczyszczania i dezynfekcji wody przeznaczonej do spożycia przez ludzi. Stwierdzono konieczność wprowadzenia w Polsce monitoringu bakterii lekoopornych występujących w środowisku wodnym.
Literature references to the presence of drug-resistant bacteria in the aquatic environment are reviewed, particular consideration being given to the water used for human consumption. The methods by which antibiotic resistance markers are transferred from the cells of the R+ donors onto the sensitive cells of the recipients are analyzed and the term "antibiotic resistance" is characterized. The mechanisms governing the specific resistance to disinfectants, not only of the bacteria but also of the microorganisms colonizing the biofilm in the water-pipe network, are discussed. Examples are given, which describe the drug-resistance of bacteria under conditions of water disinfection. Presented are data on the occurrence of drug-resistant bacteria in bottled water, as well as in the aquatic environment of recreational areas. It has been demonstrated that owing to the increasing use of drugs in human and animal therapy, the number of drug-resistant bacteria in wastewater, surface water and drinking water continues to grow. These findings provide evidence that immediate measures should be taken to ensure a rational application of antibiotics, to reduce the number of microorganisms in wastewaters (and consequently in water intakes for municipal supply), as well as to optimize the technology of water treatment and disinfection for human consumption. The need has been emphasized of monitoring the drug-resistant bacteria that are found in the aquatic environment in Poland.
Źródło:
Ochrona Środowiska; 2009, 31, 2; 11-15
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność usuwania związków biogennych w procesie uzdatniania wody
Efficiency of biogenic compounds removal in water treatment
Autorzy:
Jachimowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/399748.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
składniki biogenne
uzdatnianie wody
jakość wody pitnej
biogenic components
water treatment
quality of drinking water
Opis:
Celem pracy było określenie skuteczności usuwania związków biogennych z wody podczas procesu jej oczyszczania w zakładach uzdatniania wody Miejskiego Przedsiębiorstwa Wodociągów i Kanalizacji w Krakowie. Analizie poddano wybrane wskaźniki jakości wody przed i po procesie uzdatniania w latach 2007 – 2014. Badania przeprowadzono na wodach pobranych z zakładów, które różniły się technologią uzdatnia i wielkością produkcji. W analizowanych układach technologicznych stwierdzono, że największe zastrzeżenia budzą stężenia azotanów(V), których średnia zawartość jest większa w wodzie uzdatnionej w trzech zakładach: Rudawa, Dłubnia i Bielany.
The aim of the study was to determine the effectiveness of biogenic compounds removal from water during the treatment process in water treatment plants of Municipal Water Supply and Sewerage Company in Cracow. The selected water quality indicators were analyzed before and after the treatment process in 2007–2014. The research was carried out in waters taken from plants that differed in respect to the treatment and production method. In the analyzed technological systems, the greatest objections were raised by the concentration of nitrates, the average content of which is higher in the treated water from three plants: Rudawa, Dłubnia and Bielany.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 4; 97-106
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nuklidy promieniotwórcze w wodach pitnych na Śląsku
Natural radioactivity in the drinking water in Upper Silesia region
Autorzy:
Chmielewska, I.
Chałupnik, S.
Mielnikow, A.
Hudzik, G.
Czapla, B.
Powiązania:
https://bibliotekanauki.pl/articles/340957.pdf
Data publikacji:
2011
Wydawca:
Główny Instytut Górnictwa
Tematy:
wody pitne
nuklidy promieniotwórcze
izotopy radu
drinking water
measurement of radiation
radium isotopes
Opis:
W kopalniach węgla Górnośląskiego Zagłębia Węglowego występują słone wody o podwyższonej promieniotwórczości naturalnej, związanej z występowaniem w nich izotopów radu. Wody te mogą powodować między innymi skażenie środowiska naturalnego, a efekty skażeń są od wielu lat przedmiotem badań i problem ten jest stosunkowo dobrze rozpoznany. Jednocześnie wody z płytko zalegających warstw wodonośnych są wodami o niskiej mineralizacji i niskich, a nawet bardzo niskich, stężeniach nuklidów promieniotwórczych. W niektórych przypadkach takie wody po uzdatnieniu są wykorzystywane jako wody pitne czy technologiczne w kopalniach. Wydawać by się mogło, że w tych przypadkach nie pojawią się żadne problemy związane z promieniotwórczością naturalną. Jednakże, długotrwała filtracja wód zawierających nawet bardzo niskie stężenia takich nuklidów promieniotwórczych, jak izotopy radu czy uranu, może prowadzić do ich adsorpcji w materiałach filtracyjnych stacji uzdatniania wód i powstawania substancji o podwyższonej promieniotwórczości naturalnej. Problemy takie stwierdzono już w kilku krajach europejskich (Finlandii, Szwecji czy Austrii), a wstępne wyniki badań filtrów piaskowych ze stacji uzdatniania wód w kopalniach GZW potwierdzają istnienie takiego zjawiska. Dodatkowo, wody podziemne mogą zawierać podwyższone stężenia radonu, który w procesach uzdatniania jest zazwyczaj uwalniany do powietrza w stacji uzdatniania, co może powodować znaczący wzrost narażenia radiacyjnego pracujących tam ludzi. Takie procesy są długotrwałe i dlatego jest wskazane prowadzenie badań przez okres kilku lat, przede wszystkim w stacjach uzdatniania wód przy kopalniach węgla.
Drinking Water Directive of European Union requires a monitoring of the quality of drinking waters in Member States, also measurements of natural radioactivity. Although only for H-3 the permissible level has been established directly (100 Bq/l), for other radionuclides the Total Indicative Dose (TID) due to its intake is 0.1 mSv/year. For the monitoring of the drinking water quality a complex of methods for chemical preparation and measurements have been developed and implemented. It consists of following steps – at first, tritium analysis is done as well as gross alpha and gross beta activity is measured for each sample. For both of latter measurements liquid scintillation spectrometry with use of low level LS spectrometer Quantulus is applied. Afterwards, radium analysis is made, measurements are done for Ra-226 and Ra-228 simultaneously in LS spectrometer, preceded by chemical separation of radium from water sample with barium carrier. Simultanously to radium measurement, Pb-210 analysis is done in all samples, after coprecipitation with stable lead carrier the resulting precipitate is mixed with gelling scintillator and measurement is performed with use of Quantulus. Also uranium determination is done, at first uranium is retained at anionic ion exchange resin, than purified by means of UTEVA resin (Triskem). Finally the electrodeposition of uranium is performed and resulting sample is measured by alpha spectrometry.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2011, 2; 29-38
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Historyczne zmiany struktury sieci wodociągowej na tle utrzymania standardów wody pitnej dla miasta Łodzi
Historical changes in the water supply system and maintenance of drinking water quality standards in the city of Lodz
Autorzy:
Tomczak, E.
Dominiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/127039.pdf
Data publikacji:
2014
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wodociąg łódzki
eksploatacja wody
jakość wody pitnej
Lodz water supply system
water exploitation
quality of drinking water
Opis:
Projekt łódzkiej sieci wodociągowej, wykonany przez najlepszego europejskiego fachowca W. Lindleya, powstał już w 1909 roku. Realizację rozpoczęto w 1934 roku przy współudziale polskiego inżyniera S. Skrzywana. Po II wojnie światowej dokonano wiercenia dalszych studni głębinowych i zbudowano system wodociągowy oraz stację uzdatniania wody. Zbudowano 50 km rurociągu Tomaszów-Łódź (1955 rok), zbiornik retencyjny na Pilicy (1968-1973) i kolejne studnie głębinowe. W 2010 roku istniało już 58 ujęć wód podziemnych, dlatego też w 2013 roku zapadła decyzja o rezygnacji z ujmowania wody powierzchniowej z Zalewu Sulejowskiego. Celem pracy było przedstawienie miejsc poboru wody i struktury sieci wodociągowej, której budowa ulegała zmianom w zależności od potrzeb i rozwoju dużego miasta, w powiązaniu z uzyskiwaniem wody pitnej najwyższej jakości. Pieczę nad eksploatacją i dystrybucją nieprzerwanie od 1925 roku sprawuje Zakład Wodociągów i Kanalizacji Sp. z o.o. w Łodzi.
The water supply system for Lodz was designed in 1909 by W. Lindley who was the best European civil engineer. The works started in 1934 and were supervised by a Polish engineer S. Skrzywan. After the World War II another deep water wells were drilled and water-pipe network and water conditioning plant were built: the first line of a 50-kilometre Tomaszow-Lodz pipeline (1955), the reservoir on the Pilica River (1968-1973). Due to that Lodz had 58 groundwater intakes in 2010 a decision was made to stop taking surface water from the Sulejowski Reservoir in 2013. The aim of the paper is to present water intake points and the structure of water supply system that was modified to meet the needs of a big city and provide drinking water of the highest quality. Municipal Water and Wastewater Company in Lodz manages the exploitation, transfer and conditioning of water for Lodz since 1925.
Źródło:
Proceedings of ECOpole; 2014, 8, 1; 311-318
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany absorbancji w nadfiolecie (UV254) w wodzie w procesach uzdatniania
Autorzy:
Nowacka, A.
Włodarczyk-Makuła, M.
Powiązania:
https://bibliotekanauki.pl/articles/274170.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
woda pitna
jakość wody
uzdatnianie wody
absorbancja w nadfiolecie
drinking water
water quality
water treatment
UV absorbance
Opis:
W pracy przedstawiono wyniki analiz jednego ze wskaźników jakości wody jakim jest absorbancja w nadfiolecie (UV254). Próbki wody pobrano po poszczególnych etapach uzdatniania wody do spożycia przez ludzi w wybranym zakładzie. Średnia wartość absorbancji (UV 1m 254nm) w wodzie surowej wynosiła 11,1. Podczas uzdatniania nastąpiło obniżenie wartości początkowej o 70%, co świadczy o wysokiej skuteczności prowadzonych procesów. Po procesie ozonowania wstępnego i koagulacji objętościowej odnotowano spadek zawartości substancji organicznych wyrażanych badanym wskaźnikiem o 54%, a po ozonowaniu wstępnym i koagulacji kontaktowej - o 56% w stosunku do wartości początkowej oznaczonej dla wody surowej. Zarówno w procesie ozonowania pośredniego i filtracji na węglu aktywnym obniżenie wartości absorbancji w nadfiolecie sięgało 20%.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 1; 28-31
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies