Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "x-ray" wg kryterium: Temat


Tytuł:
Review of X-ray detection systems
Autorzy:
Urbański, Paweł
Grzebyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/27315700.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
X-ray detection
X-ray radiation
dosimetry
luminescence
Opis:
The article presents an overview and a classification of X-ray detection methods. The main motivation for its preparation was the need to select a suitable and useful method for detecting signals from a currently developed miniature micro-electro-mechanical system (MEMS) X-ray source. The described methods were divided into passive and active ones, among which can be distinguished: chemical, luminescent, thermo-luminescent, gas ionization, semiconductor, and calorimetric methods. The advantages and drawbacks of each method were underlined, as well as their usefulness for the characterisation of the miniature MEMS X-ray source.
Źródło:
Opto-Electronics Review; 2023, 31, 3; art. no. e146554
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wideband spectral emission measurements from laser-produced plasma EUV/SXR source based on a double gas puff target
Autorzy:
Arikkatt, Antony Jose
Wachulak, Przemysław
Fiedorowicz, Henryk
Bartnik, Andrzej
Czwartos, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1849155.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Plasma Spectroscopy
X-ray coherence tomography
soft X-ray
Opis:
We present spectral emission characteristics from laser-plasma EUV/SXR sources produced by irradiation of < 1 J energy laser pulse on eleven different double stream gas puff targets, with most intense electronic transitions identified in the spectral range from 1 nm to 70 nm wavelength which corresponds to photon energy from 18 eV to 1240 eV. The spectra were obtained using grazing incidence and transmission spectrographs from laser-produced plasma emission, formed by the interaction of a laser beam with a double stream gas puff target. Laser pulses with a duration of 4 ns and energy of 650 mJ were used for the experiment. We present the results obtained from three different spectrometers in the wavelength ranges of SXR (1-5.5 nm), SXR/EUV (4-15.5 nm), and EUV (10-70 nm). In this paper, detailed information about the source, gas targets under investigation, the experimental setup, spectral measurements and the results are presented and discussed. Such data may be useful for the identification of adequate spectral emissions from gasses in the EUV and SXR wavelength ranges dedicated to various experiments (i.e. broadband emission for the X-ray coherence tomography XCT) or may be used for verification of magnetohydrodynamic plasma codes.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 701-719
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
$K_{β}/K_{α}$ X-Ray Intensity Ratios for Cr, Mn, Fe, and Co Excited by 8.735 keV Energy
Autorzy:
Yılmaz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1398200.pdf
Data publikacji:
2018-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
K X-ray intensity ratios
X-ray fluorescence
cross-sections
Opis:
In this study, the K shell intensity ratios $K_{β}/K_{α}$ have been experimentally determined for the elements Cr, Mn, Fe, and Co. Measurements have been carried out at 8.735 keV excitation energy by using secondary excitation method. K X-rays emitted by samples have been counted by a Si (Li) detector with 160 eV resolutions at 5.9 keV. The measured values were compared with the calculated theoretical values. The obtained values are in good agreement with the calculated values.
Źródło:
Acta Physica Polonica A; 2018, 133, 5; 1227-1230
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar czasu ekspozycji w miernikach promieniowania rentgenowskiego
Measurement of exposure duration in the X-ray analyser
Autorzy:
Urban, Arkadiusz
Czubla, Albin
Knyziak, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/88863.pdf
Data publikacji:
2020
Wydawca:
Główny Urząd Miar
Tematy:
pomiar czasu ekspozycji
promieniowanie X
aparat rentgenowski
exposure time measurement
X-ray
X-ray machine
X-ray multimeter
Opis:
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na błąd pomiaru.
The main idea of the article is a description of problems of X-ray exposure time measurement. The content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time are presented. It also discusses the impact of different resolution settings of device under calibration on uncertainty measurement.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2020, 1 (24); 15-20
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X pinch as a source for X-ray radiography
Autorzy:
Pikuz, S.
Shelkovenko, T.
Romanova, V.
Sinars, D.
Hammer, D.
Bland, S.
Lebedev, S.
Powiązania:
https://bibliotekanauki.pl/articles/147532.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
wire array
X-pinch
X-ray imaging
X-ray radiography
Z-pinch
Opis:
This article describes several applications and methods using the X pinch as a source of X-ray radiation for the radiography of dense plasma objects. These methods, in general, do not use pinholes, and instead take the advantage of the small size (<1 mm, and in some cases <3 mm) and a short X-ray emission duration (<1 ns) of the radiation source produced by an X pinch. Two of these methods, monochromatic and direct point-projection backlighting, are discussed. Experimental images of exploding wires and wire arrays obtained on the BIN, XP, and MAGPIE generators using these techniques are presented. Also included are detailed measurements made on the XP generator of the emission characteristics of X pinches using different wire materials.
Źródło:
Nukleonika; 2001, 46, 1; 21-25
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorcowanie funkcji pomiaru czasu ekspozycji w miernikach promieniowania rentgenowskiego
Calibration of exposure duration in the X-ray analyser
Autorzy:
Urban, Arkadiusz
Czubla, Albin
Knyziak, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/268140.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wzorcowanie miernika promieniowania X
pomiar czasu ekspozycji
promieniowanie X
aparat rentgenowski
calibration
exposure time measurement
X-ray
X-ray machine
X-ray multimeter
Opis:
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na wielkość błędu.
Main idea of the article is a description of problems of X-ray exposure time measurement. Content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The article discuss differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time. It also discuss impact of different resolution settings of device under calibration on uncertainty measurement.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 91-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent measurements of soft X-ray emission from the DPF-1000U facility
Autorzy:
Surała, W.
Sadowski, M. J.
Paduch, M.
Zielinska, E.
Tomaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/148171.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray emission
X-ray images
gas puffing
filaments
hot spots
Opis:
Soft X-ray imaging is a very useful diagnostic technique in plasma-focus (PF) experiments. This paper reports results of four experimental sessions which were carried out at the DPF-1000U plasma-focus facility in 2013 and 2014. Over 200 discharges were performed at various experimental conditions. Measurements were taken using two X-ray pinhole cameras with a line of sight perpendicular to the z-axis, at different azimuthal angles (about 20° and 200°), and looking towards the centre of the PF-pinch column. They were equipped with diaphragms 1000 μm or 200–300 μm in diameter and coated with filters of 500 μm Al foil and 10 μm Be foil, respectively. Data on the neutron emission were collected with silver activation counters. For time-resolved measurements the use was made of four PIN diodes equipped with various fi lters and oriented towards the centre of the PF-column, in the direction perpendicular to the electrode axis. The recorded X-ray images revealed that when the additional gas-puff system is activated during the discharge, the stability of the discharge is improved. The data collected in these experiments confi rmed the appearance of a filamentary fi ne structure in the PF discharges. In the past years the formation of such fi laments was observed in many Z-pinch type experiments. Some of the recorded X-ray images have also revealed the appearance of the so-called hot- -spots, i.e. small plasma regions of a very intense X-ray emission. Such a phenomenon was observed before in many PF experiments, e.g. in the MAJA-PF device, but it has not been investigated so far in a large facility such as the DPF-1000U. The time-resolved measurements provided the evidence of a time lapse between the X-ray emission from plasma regions located at different distance from the anode surface. The formation of distinct ‘hot-spots’ in different instants of the DPF-1000U discharge was also observed.
Źródło:
Nukleonika; 2015, 60, 2; 303-308
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High speed signal processing for photon counting X-ray detection
Autorzy:
Shinomiya, B.
Koike, A.
Morii, H.
Okunoyama, T.
Neo, Y.
Mimura, H.
Aoki, T.
Powiązania:
https://bibliotekanauki.pl/articles/385292.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
X-ray
CdTe
photon counting
Opis:
Recently practical X-ray measurement systems are demanded energy distinction function. Photon-counting CdTe semiconductor detectors have a high energy resolution in a low count rate condition at room temperature. However, the energy resolution is decreased by pile-up phenomenon in a high count rate condition. In conventional signal processing, processing time estimated X-ray photon energy from the pulse waveform is about tens of microseconds. This time is depended on the pulse decay time. This paper purposes to maintain the high energy resolution by changing the signal-processing algorithm, which derived the pulse rise height of the output waveform from the CdTe detector in a high count rate condition. As a result, the pulse rise time required to estimate the pulse rise height was short about 100 ns at incident X-ray energy 60 keV. As the result of energy spectrum by using this data, the FWHM of about 11keV (at 60 keV) when the count rate of 500 kcps. This result shows the possibility that the photon counting sensor has application for the high count rate imaging without decrease of the high energy resolution.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 143-146
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray techniques in the investigation of a Gothic sculpture : the risen Christ
Autorzy:
Mikołajska, A.
Walczak, M.
Kaszowska, Z.
Urbańczyk-Zawadzka, M.
Powiązania:
https://bibliotekanauki.pl/articles/146866.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cultural heritage
X-ray image
X-ray dual source computed tomography (DSCT)
scanning electron microscopy energy dispersed X-ray spectroscopy (SEM-EDX)
Opis:
For over a century, X-ray radiation has played an important role in the area of the conservation and restoration of cultural heritage objects. X-ray techniques are amongst the most fundamental and helpful methods used in the investigation of art works. This paper reviews the application of traditional radiography, X-ray dual source computed tomography (DSCT) and scanning electron microscopy combined with energy dispersed X-ray spectroscopy (SEM-EDX) to the investigation of a wooden, Gothic sculpture, The risen Christ. Thanks to the properties of X-ray radiation (different absorption by various materials) first two methods allow the assessment of the preservation state and the observation of the internal structure of an object in 3-D. While SEM-EDX analysis permits the elemental analysis of the polychrome layers. As a result 2-D and 3-D images, permitting the full volume inspection of an object, were taken in a totally non-destructive way. The morphological and physical information about the inner structure of the investigated wooden sculpture was obtained, revealing changes related to previous restorations, as well as ageing effects. Employing the SEM-EDX, painting materials (pigments and filers), were identified. Gained data is essential for restorers to understand the whole structure of the studied object and to decide which further investigation and restoration steps have to be undertaken.
Źródło:
Nukleonika; 2012, 57, 4; 627-631
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study on X-ray source from Plasma Focus device for fast radiography
Autorzy:
Da Re, A.
Mezzetti, F.
Tartari, A.
Verri, G.
Rapezzi, L.
Gribkov, V. A.
Powiązania:
https://bibliotekanauki.pl/articles/147243.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray sources
Opis:
Plasma derived flash X-ray sources may find potential applications in medicine and industry. Notwithstanding, as is the case of Plasma Focus (PF) devices, their characterisation in term of photon energy, temporal and spatial beam stability is far to be considered satisfactory. In this work, a radiographic approach, which avoids the effects caused by the intrinsic instability of the pinch output of a PF machine, is proposed and an attenuation curve can be attained even in presence of Xray emission instability. Using two radiographic films for each shot exposition symmetrically positioned and collimated to the pinch region the mean energy of the photons in the X-ray beam are evaluated. The X-ray emission symmetry from the pinch region was then utilised to control the validity of the proposed methodology.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 123-125
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dense Plasma Focus as a powerful source of monochromatic X-ray radiation
Autorzy:
Dubrovsky, A.
Gribkov, V.
Ivanov, Y.
Karpiński, L.
Orlova, M.
Powiązania:
https://bibliotekanauki.pl/articles/147444.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
X-ray generation
X-ray dosimetry
exposure dose
absorbed dose
Opis:
A review of some experimental results obtained using the dense plasma focus (DPF) device PF-1000 is presented. The copper Ka1,2 radiation line generated by DPF in the case of device anode made of copper was the main object of this study. The predominance of this characteristic radiation over other kinds of radiation in the DPF X-ray spectrum is shown. A brief description of a new DPF 6.0 device as well as a radioenzymology experiment carried out within this device is presented.
Źródło:
Nukleonika; 2006, 51, 1; 21-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of the soft X-ray tungsten spectra expected to be registered by GEM detection system for WEST
Autorzy:
Syrocki, Ł.
Szymańska, E.
Słabkowska, K.
Polasik, M.
Pestka, G.
Powiązania:
https://bibliotekanauki.pl/articles/971490.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray spectra
tokamak
tungsten L, M, N, X-ray lines
GEM detection system
Opis:
In the future International Thermonuclear Experimental Reactor (ITER), the interaction between the plasma and the tungsten chosen as the plasma-facing wall material imposes that the hot central plasma loses energy by X-ray emission from tungsten ions. On the other hand, the registered X-ray spectra provide alternative diagnostics of the plasma itself. Highly ionized tungsten emits extremely complex X-ray spectra that can be understood only after exhaustive theoretical studies. The detailed analyses will be useful for proper interpretation of soft X-ray plasma radiation expected to be registered on ITER-like machines, that is, Tungsten (W) Environment in Steady-state Tokamak (WEST). The simulations of the soft X-ray spectra structures for tungsten ions have been performed using the flexible atomic code (FAC) package within the framework of collisional-radiative (CR) model approach for electron temperatures and densities relevant to WEST tokamak.
Źródło:
Nukleonika; 2016, 61, 4; 433-436
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and Characterization of Co-Cs-Nd-Sr-Doped Perovskite-Rutile-Type Structure
Autorzy:
Smolinski, T.
Zhao, L.
Rogowski, M.
Wawszczak, D.
Olczak, T.
Brykala, M.
Powiązania:
https://bibliotekanauki.pl/articles/355628.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Synroc
X-ray diffraction
Rutherford backscattering
particle induced X-ray emission
Roentgen computed microtomography
Opis:
The perovskite type matrix is considered as solidification material for high-level radioactive waste. In this work the perovskite-rutile-type matrix doped by Co, Cs, Nd and Sr which simulate nuclear waste was prepared by sol-gel route. The material was characterized by several methods such as: X-ray diffraction, energy dispersive X-ray spectrometer, and particle induced X-ray emission combined with Rutherford backscattering spectrometry. The analyzes confirmed chemical composition Co-Cs-Nd-Sr-doped perovskite-rutile-type structure. A virtual model of the pellet`s structure was created non-destructively by Roentgen computed micro-tomography. The leaching tests confirmed high chemical resistance of the matrix.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 4; 1417-1423
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray tube with needle-like anode
Autorzy:
Słapa, M.
Straś, W.
Traczyk, M.
Dora, J.
Snopek, M.
Gutowski, R.
Drabik, W.
Powiązania:
https://bibliotekanauki.pl/articles/147038.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
brachytherapy
photon needle
X-ray tube
Opis:
An X-ray tube with a needle-like anode (NAXT) built in our Laboratory, its design and basic operating parameters are presented. The process of electron beam forming and influence of external and internal magnetic fields is discussed. The tube properties essential from the point of view of its application in X-ray generators as well as disadvantageous thermal effects caused by flow of heat generated in the tube target to irradiated objects are discussed. The tube is almost a point-like source of X radiation emitted into 4đ geometry; the dose rates are on the order of 1 Gy/min at the distance of 10 mm from the anode cap. Preliminary tests show the tube may be useful in brachytherapy of cancer tumors of diameter up to 30 mm. The tube may also be an interesting device in widely understood field of irradiation techniques.
Źródło:
Nukleonika; 2002, 47, 3; 101-105
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multichannel calorimeters for measurement of flows of X-ray radiation in the range from 10 up to 200 keV
Autorzy:
Vinogradov, V. P.
Powiązania:
https://bibliotekanauki.pl/articles/148228.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
calorimeter
hard X-ray
plasma focus
Opis:
An 8-channel calorimeter was developed and applied to the Plasma focus facility (PF) with flat geometry of electrodes (Filippov type) for the measurements of a hard X-ray (HXR) radiation yield and its spectral distribution. The calorimeter measures the time-integrated HXR flux for one shot of the PF facility without any additional calibrations. The sensitivity ~10–4 J/cm2 was achieved.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 99-101
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure data at 150 K for diammonium oxalate monohydrate, [NH4]2[C2O4][H2O]
Autorzy:
Mielniczek-Brzóska, E.
Dmytriv, G.
Pavlyuk, V.
Griffin, A.
Powiązania:
https://bibliotekanauki.pl/articles/410252.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
oxalates
crystal structure
X-ray diffraction
Opis:
The single crystals of perfectly quality of the diammonium oxalate monohydrate, [NH4]2[C2O4][H2O], were obtained by the improved methods of crystal growth from solution. The crystal structure of title compound was studied at 150 K using modern X-ray equipment. At this temperature, as well as at room temperature, this compound crystallizes in the orthorhombic symmetry wiith P21212 space group. The unit cell of the title compound is formed by four amonium cations, two oxalate anions and water molecules, with a 2:1:1 cation-anion-water ratio. At 150 K oxalate ion is twisted by 26.9 (1)°. The similar twist angle (26.6 (4)° was observed at the room temperature. Central carbon-carbon bond in oxalate ion is insignificantly longer (1.568 Å) in comparing with this bond at room temperature (1.559 Å).
Źródło:
Chemistry, Environment, Biotechnology; 2013, 16; 73-78
2083-7097
Pojawia się w:
Chemistry, Environment, Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantitative Characteristic X-Ray Analysis for Different Compound Samples by Using Monte Carlo Method
Autorzy:
Tekın, H.
Altunsoy, E.
Manici, T.
Yilmaz, B.
Powiązania:
https://bibliotekanauki.pl/articles/1030113.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Monte Carlo
characteristic X-ray
brass
Opis:
X-ray spectrometry is an elemental analysis technique with broad application in science and industry. It is based on the principle that individual atoms, when excited by an external energy source emit X-ray photons of a characteristic energy or wavelength. Here we obtained the characteristic X-ray peaks of different brass compounds and compared the intensity of characteristic peaks by changing with Zn rate. In this study we modelled different brass samples by using Monte Carlo method and changed the zinc rate in brass samples for each compound. We obtained the characteristic X-ray peaks of different compounds and compared the intensity of characteristic peaks by changing with Zn rate. We achieved a good agreement between peak intensity and corresponding element rate in compound. Also we obtained that characteristic peak rate increases by corresponding element rate in compound. This study shows that Monte Carlo method is very effective method to simulate material features due to their characteristic peaks and their intensities.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 439-441
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
57Fe Mössbauer spectroscopy and X-ray diffraction study of gadolinites REE2Fe2+Be2Si2O10 from Lower Silesia (Poland) and Ytterby (Sweden)
Autorzy:
Malczewski, D.
Powiązania:
https://bibliotekanauki.pl/articles/148858.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gadolinite
Mössbauer spectroscopy
X-ray diffraction
Opis:
This paper reports the results of 57Fe Mössbauer spectroscopy, X-ray diffraction (XRD) and gamma-ray spectroscopy studies of partially metamict gadolinites from Szklarska Poręba and Zimnik (Lower Silesia, Poland), a fully metamict gadolinite sample from Ytterby (Sweden) and a crystalline sample obtained after annealing of a fragment of the sample from Ytterby at 1373 K in an argon atmosphere. Both fully metamict and crystalline gadolinite show divalent iron exclusively in octahedral coordination. Changes of the amplitudes ratio of high energy to low energy absorption peaks from Fe2+ quadrupole doublets are strictly correlated with calculated absorbed alpha-dose and the metamictization stages of the gadolinite specimens. In this respect, one of the samples is in conflict with the estimated radiation dose based on age and radionuclide concentrations. In this case, Mössbauer spectroscopy shows that the sample had to be naturally annealed over geologic time.
Źródło:
Nukleonika; 2003, 48,suppl.1; 41-44
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conceptual design of Light Impurity Monitor for Wendelstein 7-X
Autorzy:
Książek, I.
Burhenn, R.
Musielok, J.
Powiązania:
https://bibliotekanauki.pl/articles/146640.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma spectroscopy
stellarator
soft X-ray
Opis:
As plasma impurity ions can significantly influence the properties of a fusion plasma by dilution and enhancement of the radiation losses, the process of monitoring of their concentrations is one of the most important tasks. A Light Impurity Monitor is needed for monitoring the contamination of the stellarator plasma by carbon, nitrogen, boron, and oxygen impurities, which are indicators for the overload of the plasma facing components, leakage of the vacuum vessel, or wall condition, respectively. Their concentration will be estimated on the basis of emission intensities of their hydrogen-like ions. In this paper a conceptual design of such a spectrometer is presented, including the description of the geometry, the acquisition system and safety systems.
Źródło:
Nukleonika; 2011, 56, 2; 155-160
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Behavior of Jordanian Oil Shale during Combustion Process from the El-Lajjun Deposit
Autorzy:
Gougazeh, Mousa
Alsaqoor, Sameh
Borowski, Gabriel
Alsafasfeh, Ashraf
Hdaib, Ismail I.
Powiązania:
https://bibliotekanauki.pl/articles/2173323.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
El-Lajjun oil shale
combustion
X-ray diffraction
thermogravimetric
fourier transform infrared spectroscopy
X-ray fluorescence
Opis:
The results of X-ray diffraction, thermogravimetric and FTIR spectroscopy analyses of mineral composition indicated that the El-Lajjun oil shale is principally composed of calcite, quartz with minor amounts of kaolinite), gypsum, and apatite. The obtained oil shale ash products at 830 °C and 1030 °C are dominated by lime, quartz, anhydrite, portlandite, gehlenite, and amorphous phases. The TGA weight loss curves clearly indicate that it occurred in the temperature range from 310 to 650 °C. The decomposition of oil shale carbonates was detected above 750°C. The functional groups in the organic material of oil shale are dominated by the aliphatic hydrocarbons, the semi-ash of which had diverse structures of polycyclic aromatic hydrocarbons. The most intensive of combustion occurred in the temperature range of 400–750 °C. In this temperature range, about 75 wt.% was accounted for the total mass loss.
Źródło:
Journal of Ecological Engineering; 2022, 23, 8; 133--140
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The concept of implementation of a clinical audit as a tool for evaluating quality management in X-ray diagnostics
Koncepcja realizacji audytu klinicznego jako narzędzia do oceny poziomu zarządzania jakością w rentgenodiagnostyce
Autorzy:
Sergot, M.
Powiązania:
https://bibliotekanauki.pl/articles/202713.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
clinical audit
management
quality
X-ray imaging
X-ray facilities
audyt kliniczny
zarządzanie
jakość
rentgenodiagnostyka
pracownia rtg
Opis:
The article discusses the clinical implementation of internal audits in enterprises that use ionizing radiation in X-ray diagnostics. The legal aspects involved in conducting clinical audits and their implementation are presented. Rules which have to be obeyed during an audit of a quality management system are compared in an analysis with the rules accommodated during a clinical audit led by state authorities. This analysis presents some similarities between the analyzed forms of checking the management system’s condition in X-ray diagnostics. In addition to similarities, there exist some differences also, and they are pointed out in this analysis, that is, elements that distinguish the audits from each other. Both a quality management system’s audit and control components can be used for a clinical audit. The author designed a simple workflow during the internal clinical audit. The conclusions of the analysis will be the subject of further research.
W artykule opisano problem wdrożenia wewnętrznych audytów klinicznych w przedsiębiorstwach wykorzystujących promieniowanie jonizujące w rentgenodiagnostyce. Przywołano prawne aspekty przeprowadzania audytów klinicznych oraz ich wdrażania. Dokonano analizy porównawczej reguł przeprowadzania audytów systemu zarządzania jakością z regułami przeprowadzania audytów klinicznych i regułami przeprowadzania kontroli organów państwowych. W konsekwencji tej analizy wskazano podobieństwa pomiędzy analizowanymi formami sprawdzania stanu systemu zarządzania w rentgenodiagnostyce. Zwrócono również uwagę na elementy odróżniające je od siebie, a także możliwość adaptacji elementów audytu systemu zarządzania jakością i elementów kontroli organów państwowych na rzecz audytu klinicznego. Opracowano prosty schemat postępowania podczas wewnętrznego audytu klinicznego. Wnioski z przeprowadzonej analizy stanowić będą przedmiot dalszych badań.
Źródło:
Zeszyty Naukowe Politechniki Poznańskiej. Organizacja i Zarządzanie; 2016, 69; 81-96
0239-9415
Pojawia się w:
Zeszyty Naukowe Politechniki Poznańskiej. Organizacja i Zarządzanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezgodności z wymogami ochrony radiologicznej występujące w rentgenodiagnostyce oraz propozycje ich usunięcia
Radiodiagnostics and inconsistencies with the requirements of radiological protection along with propositions for their elimination
Autorzy:
Sergot, M.
Powiązania:
https://bibliotekanauki.pl/articles/179082.pdf
Data publikacji:
2017
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ochrona radiologiczna
promieniowanie jonizujące
rentgenodiagnostyka
bezpieczeństwo rtg
radiological protection
ionizing radiation
X-ray diagnostics
X-ray safety
Opis:
W artykule zaprezentowano podstawową problematykę z zakresu ochrony radiologicznej. Została również przeanalizowana aktualna sytuacja dotycząca niezgodności występujących podczas organizacji bezpieczeństwa pracy przy promieniowaniu rentgenowskim. Celem artykułu było opracowanie rozwiązania występujących niezgodności. Aby osiągnąć przedstawiony cel zaproponowano zmiany, które mogą mieć istotny wpływ na poprawę poziomu bezpieczeństwa pracowników na wybranym stanowisku oraz pacjentów. Dokonano analizy literatury z zakresu negatywnego oddziaływania promieniowania rentgenowskiego na organizm człowieka. Podzielono tak ze istniejące środki ochrony ze względu na osłonę dla pacjenta i pracownika oraz ogół ludności. Wykonano badania w 33 jednostkach ochrony zdrowia w celu weryfikacji stosowanej ochrony radiologicznej i niezgodności z nią związanych.
This article discusses some basic issues in radiological protection. It also analyzes problems in occupational safety related to X-rays. To solve those problems, it necessary to introduce several changes, which could significantly improve the level of safety of workers at selected workstations and patients. This article presents an analysis of the literature on the negative impact X-rays have on the human body, rays and a classification of existing safety measures according to whether they protect patients, personnel or the general population. To verify inconsistencies with the requirements of radiological protection, measurements were conducted at 33 health care facilities.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2017, 5; 11-15
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Second order reflection from crystals used in soft X-ray spectroscopy
Autorzy:
Książek, I.
Powiązania:
https://bibliotekanauki.pl/articles/146093.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
plasma spectroscopy
PbSt
KAP
Opis:
In this note the ratio of the second to the first order reflection is determined for the KAP and PbSt crystals, for wavelengths corresponding to the Al K-line emission. The source of the radiation was a low-voltage stabilized X-ray tube. The X-rays were detected with a Bragg spectrometer equipped with a proportional counter detector. The signal measured by the proportional counter was subsequently pulse height analyzed.
Źródło:
Nukleonika; 2015, 60, 2; 263-265
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of soft X-ray tomography on the COMPASS tokamak
Autorzy:
Imríšek, M.
Mlynář, J.
Löffelmann, V.
Weinzettl, V.
Odstrčil, T.
Odstrčil, M.
Tomeš, M.
Powiązania:
https://bibliotekanauki.pl/articles/146251.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
tomography
Tikhonov regularization
tokamak
Opis:
The COMPASS tokamak is equipped with the soft X-ray (SXR) diagnostic system based on silicon photodiode arrays shielded by a thin beryllium foil. The diagnostic is composed of two pinhole cameras having 35 channels each and one vertical pinhole camera with 20 channels, which was installed recently to improve tomographic inversions. Lines of sight of the SXR detectors cover almost complete poloidal cross section of the COMPASS vessel with a spatial resolution of 1–2 cm and temporal resolution of about 3 s. Local emissivity is reconstructed via Tikhonov regularization constrained by minimum Fisher information that provides reliable and robust solution despite limited number of projections and ill-conditionality of this task. Improved border conditions and numerical differentiation matrices suppressing artifacts in reconstructed radiation were implemented in the code. Furthermore, a fast algorithm eliminating iterative processes was developed, and it is foreseen to be tested in real-time plasma control.
Źródło:
Nukleonika; 2016, 61, 4; 403-408
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy transformation in Plasma Focus discharge with wire and liner as a load
Autorzy:
Kubeš, P.
Kravárik, J.
Klír, D.
Scholz, M.
Paduch, M.
Tomaszewski, K.
Karpinski, L.
Ryc, L.
Juha, L.
Krasa, J.
Szydlowski, A.
Romanova, V.
Powiązania:
https://bibliotekanauki.pl/articles/147107.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray source
XUV spectroscopy
Opis:
We present the results of experiments focused on energy transformations during the implosion of the hydrogen current sheath towards an Al wire (120 ěm in diameter) positioned on the top of the inner electrode of the PF-1000 plasma focus facility at the IPPLM in Warsaw. A wire corona is formed at the current sheath impact and ~60 ns after the impact a soft X-ray pulse is emitted. Its spectrum contains AlVI-XII lines accompanied by their satellites. The amount of emitted energy is recorded by two filtered PIN diodes and thermoluminescent dosimeters and depends on symmetry of the current sheath and quality of the current sheath focus. The mean value of energy of keV photons emitted in the runs done without the wire (~1 J) is higher than the energy obtained with the wire (~0.4 J). A time delay between the impact of the current sheath and X-ray pulse, the plasma focus dynamics and soft X-ray emission are interpreted by an axial magnetic field generation and transformations.
Źródło:
Nukleonika; 2002, 47, 4; 151-153
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and Characterization of the Energetic Compounds Aminoguanidinium-, Triaminoguanidiniumand Azidoformamidinium Perchlorate
Autorzy:
Klapötke, T. M.
Stierstorfer, J.
Powiązania:
https://bibliotekanauki.pl/articles/358855.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
perchlorates
energetic salts
calorimetry
X-ray
DSC
Opis:
Aminoguanidinium perchlorate (2, AGClO4) was formed by the reaction of aminoguanidinium bicarbonate (1) with aqueous perchloric acid solution. Triaminoguanidinium perchlorate (3, TAGClO4) was synthesized by nucleophilic attack of aqueous hydrazine solution on aminoguanidinium perchlorate under release of ammonia. The new and highly explosive azidoformamidinium perchlorate (4, AFClO4) was formed by the reaction of aminoguanidinium perchlorate with potassium nitrite under acidic conditions. The structures of the perchlorate salts in the crystalline state were determined using low temperature single crystal X-ray diffraction yielding monoclinic as well as orthorhombic structures. The compounds were characterized comprehensively using vibrational spectroscopy (IR and Raman), multinuclear (1H, 13C and 15N) NMR spectroscopy, elemental analysis and mass spectrometry. The thermal behavior as well as the decompositions were investigated using DSC (differential scanning calorimetry) and the heats of formation were calculated using heats of combustion determined by bomb calorimetric measurements. In addition, the sensitivities were evaluated using BAM methods (drophammer and friction tester), whereby the perchlorate salts are all sensitive towards impact as well as friction.
Źródło:
Central European Journal of Energetic Materials; 2008, 5, 1; 13-30
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Quality Control Test for General X-Ray Machine
Autorzy:
AL-Jasim, Ali Kareem
Hulugalle, S.N.C.W.M.P.S.K.
Al-Hamadani, Haider Kamil
Powiązania:
https://bibliotekanauki.pl/articles/1178771.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Quality Assurance
Quality Control
X-Ray Machine
Opis:
The aim of a quality assurance program is to assist a radio-diagnostic facility in consistently obtaining adequate radiological information with a minimum of dose and a minimum of cost. An integrated part of a quality assurance program is quality control ascertaining quality by measurements and other procedures. When procuring equipment, a specification is worked out taking into account all aspects of the performance of the equipment including the desired tolerances of technique factors. In this study the seven tests (beam alignment, beam collimation, reproducibility, accuracy of kv, time accuracy, half value layer (HVL) and leakage) were carried out for the newly installed General X-Ray machine at Nuclear Malaysia and were in the acceptable limits. Such a test will be the responsibility of a qualified physicist or engineer. The status test is carried out in order to establish the functional status of the equipment. The test is performed immediately after the acceptance test or as an integrated part of it. The test will be repeated when repair influencing the functional status has taken place like the acceptance test; the status test will comprise absolute measurements and will likewise be the responsibility of a qualified physicist or engineer.
Źródło:
World Scientific News; 2017, 90; 11-30
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Calcium Ions on the Structure and Properties of LaMnO3
Autorzy:
Bara, M.
Dzik, J.
Feliksik, K.
Kozielski, L.
Wodecka-Duś, B.
Goryczka, T.
Zarycka, A.
Adamczyk-Habrajska, M.
Powiązania:
https://bibliotekanauki.pl/articles/353112.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCMO
ceramics
manganites
X-ray diffraction
SEM
Opis:
La0,7 Ca0,3 MnO3 polycrystalline were synthesized from La2 O3 , CaO and MnO2 powder mixture using a solid state reaction technique. The compound powders were obtained through the free sintering method at different temperatures and sintering times in order to study the influence of technological conditions on Ca doped La manganites. The most important physical features as structure, microstructure and morphology were described after X-ray diffraction investigation. Photographs of the specimen fractures were taken with SEM (scanning electron microscope) and they revealed high porosity of the tested material and great tendency for its grains to create agglomerates. Influence of doping and technological conditions on lattice parameters were studied by means of Rietvield analysis. The XRD measurements reveal that La0,7 Ca0,3 MnO3 has orthorhombic symmetry with Pnma space group.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 3; 1189-1195
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation Of Intermetallic Compounds In Sn-Cu-Ni Lead-Free Solders
Badanie związków międzymetalicznych w bezołowiowych stopach lutowniczych Sn-Cu-Ni
Autorzy:
Nagy, E.
Kristaly, F.
Gyenes, A.
Gacsi, Z.
Powiązania:
https://bibliotekanauki.pl/articles/353266.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
intermetallic
lead-free solder
X-ray diffraction
Opis:
Interfacial intermetallic compounds (IMC) play an important role in Sn-Cu lead-free soldering. The size and morphology of the intermetallic compounds formed between the lead-free solder and the Cu substrate have a significant effect on the mechanical strength of the solder joint. In the soldering process of Sn-Cu alloys, Cu6Sn5 intermetallic compounds are formed. The complex structural behaviour of Cu6Sn5 IMC is temperature- and composition-dependent and it is long since subject to scientific research. The Cu6Sn5 phase basically exists in two crystal structures: hexagonal η-Cu6Sn5 (at temperatures above 186°C) and monoclinic η’-Cu6Sn5 (at lower temperatures). In the presence of Ni in the solder, the η-η’ transformation does not occur, therefore, the η-Cu6Sn5 phase remains stable. In this study the role of Ni in the (Cu,Ni)6Sn5 intermetallic compound in Sn-Cu lead-free solders was examined. Sn-Cu alloys with different Cu content (0.5 to 1 mass%) were modified through Ni addition. The morphology of the intermetallic compounds of the modified Sn-Cu alloys was investigated by optical microscopy (OM) and scanning electron microscopy (SEM), the IMC phases were examined with X-ray diffraction method (XRD).
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2B; 1511-1515
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Depth dependent X-ray diffraction of porous anodic alumina films filled with cubic YAlO3:Tb3+ matrix
Autorzy:
Serafińczuk, Jarosław
Pawlaczyk, Łukasz
Podhorodecki, Artur
Gaponenko, Nikolai
Molchan, Igor
Thompson, George
Powiązania:
https://bibliotekanauki.pl/articles/173841.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
PAA
X-ray diffraction
AFM
SEM
crystallization
Opis:
The presented paper deals with the measurement methodologies of the structural properties of porous anodic alumina (PAA) films filled with YalO3:Tb3+ composite using X-ray diffraction, atomic force microscopy and scanning electron microscopy. It shows that the deposited material does not uniformly fill the porous volume of the anodic alumina film and the part of it forms a thick layer on the PAA surface. The aim of this work is to show the differences in the XRD response obtained at different angles of incidence of the excitation beam for the PAA/YalO3:Tb3+ system. Furthermore, this simple approach enables separation of the signal from both regions on the surface and inside the PAA pores, providing more accurate data interpretation. It reveals that the crystallization of the material on the PAA surface and within the pores is different.
Źródło:
Optica Applicata; 2020, 50, 1; 127-134
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intrinsic linewidth calculation in an argon X-ray laser based on the model of geometrically dependent gain coefficient
Autorzy:
Hariri, A.
Sarikhani, S.
Powiązania:
https://bibliotekanauki.pl/articles/174753.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Ar X-ray laser
intrinsic linewidth
ASE
Opis:
By introducing differential amplified spontaneous emission intensity, numerical calculations for both homogeneously and Doppler broadened lines, and using the reported experimental measurements of the amplified spontaneous emission intensity and linewidth, we managed to explain the linewidth behavior, and calculate the intrinsic linewidth due to Voigt-profile width in an argon X-ray laser operating at 440 × 10–3 torr argon pressure and current of 21 kA. For the calculation, the intensity rate equation, along with the model of geometrically dependent gain coefficient were applied. The calculated value of the intrinsic linewidth was found to be 55.67 mÅ, which is very close to the Doppler broadened line of 53.52 mÅ. That is, the collision broadening has a very small contribution to the light-matter interaction in argon X-ray lasers. Details of the procedure used for the calculation will be presented in this paper.
Źródło:
Optica Applicata; 2017, 47, 2; 325-335
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Enlargement of Type II Burst After Type III at AR 12522 on 16th March 2016 In Conjunction With Flare-Related Coronal Mass Ejections Event
Autorzy:
Husien, Nurulhazwani
Hamidi, Z. S.
Shariff, N. N. M.
Ali, M. O.
Zainol, N. H.
Sabri, S. N. U.
Monstein, C.
Powiązania:
https://bibliotekanauki.pl/articles/1178545.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Coronal Mass Ejections
Sun
X-ray emission
Opis:
On 16th March 2016 the solar radio burst type II is recorded to appear on spectrograph after the type III formation. These two bursts related to the Coronal Mass Ejections (CMEs) event that recorded by the SOHO spacecraft several minutes before the formation of Type III on the spectrograph. It has been reported that the Type III burst a fast drift compared to the Type II burst. In this paper, the calculation has been proved that the type III burst has a higher drift rate compared to Type II. These two events of Type II and III burst also has been contributing to the formation of C class flare with magnitude of C2.2 It is also proven that the type III burst has a fast drift rate compared to type II burst. In this case, the type III has a fast drift rate of 81% compared to the type II burst. During this event, the active region AR 12522 erupted the C-class X-ray emission with magnitude of C2.2 contribute to these type III and II burst
Źródło:
World Scientific News; 2017, 70, 2; 230-240
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of X-ray on fibroblast mechanical properties
Autorzy:
Heydarian, Ashkan
Khorramymehr, Siamak
Vasaghi-Gharamaleki, Behnoosh
Powiązania:
https://bibliotekanauki.pl/articles/280421.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
viscoelastic
biomechanics
cellular mechanics
X-ray effects
Opis:
Concerning the widespread use of X-rays to detect various diseases, such as oral and dental ones, it is essential to study the effects of this radiation on living cells. From the past, genetic effects and cell death because of X-rays have been studied. In addition, the effect of this ionizing radiation on the mechanical properties of the cell and cytoskeleton has been studied, but different results have been obtained based on different models. In this study, post-culture gingival fibroblast cells were classified into two groups of control and radiation with Nano Magnetic Particles functionalized by folic acid. The cells of the radiation group were exposed to X-rays of 3 mGy·cm2 . The specimens were undergone static creep test by a magnetic tweezer. Spring and damper coefficients were obtained based on the viscoelastic solid modeling. The static and dynamic stiffness of the groups was also calculated. The maximum deformation was decreased after radiation from 0.049 ± 0.01 µm to 0.029 ± 0.01 µm and the static stiffness of the model was 1.6 times decreased. Also, the gel point frequency for the control group was 27 Hz and for the radiation group was 7.5 Hz. The results show that the static and dynamic stiffness of the cells decreases after radiation, and less deformation appears in the cells after irradiation. These changes can be due to the breakdown of membrane chemical bonds and activation of actin fibers after radiation.
Źródło:
Journal of Theoretical and Applied Mechanics; 2019, 57, 4; 999-1008
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Refined design of a new driver for fast capillary discharge
Autorzy:
Koláček, K.
Boháček, V.
Šunka, P.
Řípa, M.
Kravárik, J.
Powiązania:
https://bibliotekanauki.pl/articles/148339.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast capillary discharge
soft X-ray laser
Opis:
A new driver of the fast capillary discharge has been designed. It consists of the Marx generator and radial Blumline pulse forming line. Such a geometry enables axial access to both capillary ends (”transparent capillary”). This arrangement substantially simplifies the experiments (adjustment, monitoring, applications). The designed apparatus is capable of reaching the discharge current of the order of 120 kA and the discharge current rise time 2.9×1012 A/s, which is sufficient for the investigation of amplification in non-traditional electronic transitions.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 45-47
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dena, a new PF device
Autorzy:
Tafreshi, M. A.
Farrahi, M.
Lamehi, M.
Goudarzi, S.
Habibi, H.
Memarzadeh, M.
Siahpoush, V.
Saeedzadeh, E.
Vinogradov, V. P.
Krauz, V. I.
Krivtsov, V. A.
Karakin, M. A.
Myalton, V. V.
Tykshaev, V. P.
Powiązania:
https://bibliotekanauki.pl/articles/148836.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
Dena
focus
fusion
neutron
plasma
X-ray
Opis:
In this paper we are going to introduce “Dena”, a new Filippov type plasma focus facility, with a condenser bank of 0.288 mF, and a maximum supplying energy of 90 kJ (at Vmax= 25 kV). The facility was installed and started to work in the first quarter of the year 2000. Major points of the paper are: – Dena’s construction, functionality, and diagnostic system. – Preliminary results: Different modes of neutron, X-ray, and “hot spot” production, as well as the possibility of controlling operational mode, by changing anode configuration and initial discharge condition.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 85-87
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray stress measurements in the institute of aviation possibilities and examples
Autorzy:
Gadalińska, E.
Malicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/242492.pdf
Data publikacji:
2018
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
X-ray diffraction
residual stress measurements
fatigue
Opis:
From the point of view of the airplane construction, its fatigue lifetime and exploitation process, the stress states and levels are of crucial importance. The most appropriate experimental methods to determine stress values are diffraction methods with different radiation type employed. These methods allow the determination of the elastic lattice deformation and distortion (effectively the stress state) from the displacement and broadening of the diffraction peak. Diffraction methods are widely known as the experimental methods for determining not only the stress values but also the elastic properties of polycrystalline materials (also of all alloys types used in the aerospace industry). The advantages of diffraction experiments result from their non-destructive character and the possibility to obtain absolute values of stresses in different phases of each type of crystal material (the measurements are performed selectively only for crystallites contributing to the measured diffraction peak, i.e. for the grains having lattice orientations for which the Bragg condition is fulfilled). In the frame of this work, the laboratory possibilities of the Institute of Aviation in this area are presented as well as the exemplary results of stress measurements performed there.
Źródło:
Journal of KONES; 2018, 25, 3; 159-166
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Refined design of a new driver for fast capillary discharge
Autorzy:
Kolácek, K.
Bohacek, V.
Schmidt, J.
Sunka, P.
Ripa, M.
Kravárik, J.
Powiązania:
https://bibliotekanauki.pl/articles/147571.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast capillary discharge
soft X-ray laser
Opis:
A new driver of the fast capillary discharge has been designed. It consists of the Marx generator and radial Blumline pulse forming line. Such a geometry enables axial access to both capillary ends ("transparent capillary"). This arrangement substantially simplifies the experiments (adjustment, monitoring, applications). The designed apparatus is capable of reaching the discharge current of the order of 120 kA and the discharge current rise time 2.9×1012 A/s, which is sufficient for the investigation of amplification in non-traditional electronic transitions.
Źródło:
Nukleonika; 2001, 46, 3; 117-120
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preparation of Samples used in Fatigue Testing of Aircraft Materials
Autorzy:
Manaj, W.
Wronicz, W.
Michałowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/98020.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
mechanical processing
stress measurement
X-ray diffraction
Opis:
The application of a new type of alloy requires the evaluation of its properties, which is typically achieved with destructive methods. For this purpose, among others, static and fatigue mechanical tests are performed. Tests are performed on standardized samples in a way which reflects the level of stress occurring in real elements. These tests should limit random errors associated with sample preparation. For this reason the proper preparation of samples is crucial, not only in terms of their geometric dimensions but also in terms of the residual stress level. A sample preparation process was developed, involving checking samples’ surface for cracks, scratches, roughness, and the state of stress. The measurements are performed with nondestructive methods so as not to affect the proceeding research. In this study, the residual stress and features of a mechanically prepared surface were characterized. The specimens were subjected to various surface finishes mainly, lathe turning and grinding surface conditions. The effects of residual surface stress (measured by XRD) were studied after machining and polishing.
Źródło:
Fatigue of Aircraft Structures; 2015, 7; 66-68
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanically Stimulated Changes in Surface Electrical Conductivity of X-Irradiated Silicon Crystals
Autorzy:
Lys, Roman
Żyłka, Marta
Shykorjak, Josyp
Slobodzyan, Dmytro
Żyłka, Wojciech
Pavlyk, Bohdan
Powiązania:
https://bibliotekanauki.pl/articles/2201919.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
X-ray irradiation
silicon
uniaxial deformation
dislocation
Opis:
Changes in the resistance of single crystals of p-type conductivity silicon under the action of mechanical loading were investigated in this research. Also, non-irradiated and pre-irradiated X-rays experimental samples were studied. It was found that at small deformation values when they are at the initial stage of the action of elastic deformation, a section forms and increases, on which the resistance practically does not depend on the applied mechanical load. In irradiated crystals, at small deformation values, electron generation processes dominate, which then recombine with the main carriers – holes. The consequence of such processes is the appearance of a maximum increase in electrical resistance at the initial stage of elastic deformation of experimental samples irradiated with X-rays. Charge carrier generation processes begin to dominate with further deformation. Such processes occur as a result of the release of acceptor centers from other complex defects, which are destroyed during the deformation of the Si crystal and captured by mobile dislocations. Thus, the processes of generation of charge carriers prevail over the processes of gettering and, accordingly, a mechano-stimulated decrease in the electrical resistance of p-Si samples occurs.
Źródło:
Advances in Science and Technology. Research Journal; 2023, 17, 2; 226--231
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniki dyfrakcji rentgenowskiej
Autorzy:
Bonarski, J
Powiązania:
https://bibliotekanauki.pl/articles/273763.pdf
Data publikacji:
2013
Wydawca:
Roble
Tematy:
dyfrakcja rentgenowska
mikrostruktura
rentgenowska ilościowa analiza fazowa
RIAF
rentgenowska tomografia teksturowa
RTT
mikroskopia akustyczna
X-ray diffraction
microstructure
X-ray quantitative phase analysis
X-ray texture chromatography
acoustic microscopy
Źródło:
LAB Laboratoria, Aparatura, Badania; 2013, 18, 4; 26-30
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of High-Energy Laser coupled with Gamma – Lonizing Irradiations as New Sterilizing Technique
Autorzy:
Elsabawy, Khaled M.
Powiązania:
https://bibliotekanauki.pl/articles/1192077.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Nd-Laser
Gamma-ray
Sterilizing
X-Ray
SEM
AFM
Opis:
The present investigations introduce for first time new trend of coupling of two sterilizing sources, high energy Nd-Laser and Gamma – irradiations which has oxidative nature by additional to its thermal effects. The investigated samples will be examined before and after radiations to confirm its internal structure (XRD, microstructure (SEM, AFM, Raman-Spectra) and killing ratio for polluted bacteria. Furthermore some selected biological tests will be checked to be sure from toxicity ratio after radiations. Also many of investigational parameters will be tested such as strength of irradiation dose and irradiation dosage time to achieve maximum healthy sterilizing ratio per minimum time to validate application and wide scale application of this promising sterilizing technique.
Źródło:
World Scientific News; 2016, 37; 61-75
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High resolution x-ray tomography as a tool for analysis of internal textures in meteorites
Autorzy:
Krzesińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/411476.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Meteorytowe
Tematy:
NWA-5929
Ghubara
Pułtusk
wysoka rozdzielczość X-ray tomografii komputerowej
deformacja
high resolution X-ray computed tomography
deformation
Opis:
A comparison of internal textures of the NWA-5929, Ghubara and Pułtusk chondrites has been carried out using high resolution X-ray tomography. This is a powerful, non-destructive technique that allows on to determine textural and compositional dierences that occur between ordinary chondrites of various groups by means of grey-levels calehistograms, first-order statistics, and 3D imaging. Deformational structures in the Pułtusk meteorite such as cataclastic zones, impact melt clasts, melt veins, and melt pockets are observed and studied. Measurements of metal particle size are achieved, giving even deeper insight into textural features of meteorite. My approach shows that as shock deformation occurred, numerous small metal grains became progressively dispersed within the volume of the deformed Pułtusk meteorite rock. Simultaneously, metal was mobilized via frictional or direct impact melting to form scarce large metal nodules or grains arranged along the margins of relict chondritic clasts or as components of irregular injection veining. The possibility of tracing of these impact related processes by using tomography micrograms (without breaking the sample) is very useful for distinguishing which parts of each meteorite were deformed in diferent ways in order to make first order observations regarding the deformational history of these meteorites.
Źródło:
Meteorites; 2011, 1, 1; 3-12
2299-0313
2299-1220
Pojawia się w:
Meteorites
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray diffraction and Mössbauer spectroscopy studies of a mechanosynthesized Fe75B25 alloy
Autorzy:
Jartych, E.
Kubalova, L. M.
Fadeeva, V. I.
Powiązania:
https://bibliotekanauki.pl/articles/146344.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
mechanosynthesis
metastable phase
Mössbauer spectroscopy
X-ray diffraction
Opis:
In this work, the process of formation of metastable phases was investigated for the Fe75B25 composition. Mechanical synthesis was performed in a MAPF-2M high-energy planetary ball mill under an argon atmosphere. X-ray diffraction (XRD), differential scanning calorimetry (DSC), and Mössbauer spectroscopy (MS) were applied to recognize the phases. After 6 h of milling, the material consisted of two phases, that is, metastable tetragonal t-Fe2B and amorphous phases. During further thermal processing, the metastable phase was transformed into the stable Fe2B phase.
Źródło:
Nukleonika; 2015, 60, 1; 43 -46
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Three-channel X-ray detection head for diagnostics of plasma in noisy environment
Autorzy:
Ryć, L.
Kaczmarczyk, J.
Martinez, J. F.
Scholz, M.
Słysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/148717.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
high-temperature plasma
semiconductor detector
X-ray diagnostics
Opis:
A compact, three-channel, noise-resistant detection head based on semiconductor detectors has been built for the diagnostics of X-ray emission from plasmas. It is useful in the energy range of 0.5–20 keV.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 95-97
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Observation of intrapulse energy switching in standing-wave electron linac
Autorzy:
Matusiak, Michał
Kosiński, Tymoteusz
Wronka, Sławomir
Zakrzewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173383.pdf
Data publikacji:
2022
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cargo scanning
dual-energy imaging
X-ray imaging
Opis:
For the development of an effective cargo-scanning system, an intrapulse energy switching has been tested at the National Centre for Nuclear Research (NCBJ) with the possibility to change the beam energy within a 4 μs pulse of the linear electron accelerator (linac). Modifi cation of the electron energy is achieved through the beam-loading effect in a standing-wave accelerating structure equipped with a triode gun. Construction of the machine and the achieved results are presented in this article.
Źródło:
Nukleonika; 2022, 67, 3; 43--47
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metal-induced asthma and chest X-ray changes in welders
Autorzy:
Wittczak, Tomasz
Dudek, Wojciech
Walusiak-Skorupa, Jolanta
Świerczyńska-Machura, Dominika
Cader, Wojciech
Kowalczyk, Monika
Pałczyński, Cezary
Powiązania:
https://bibliotekanauki.pl/articles/2180086.pdf
Data publikacji:
2012-06-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
welders
metals
occupational asthma
chest X-ray changes
Opis:
Objectives: The aim of this study was to evaluate the coexisting factors and usefulness of diagnostic methods in metal-induced asthma in Polish welders. Materials and Methods: Examination of 50 welders occupationally exposed to metals and with suspicion of metal-induced asthma (group A), 100 welders occupationally exposed to metals but without suspicion of metal-induced asthma (group B), and two control groups (10 patients with atopic asthma and 10 healthy subjects) was carried out. Questionnaire survey, clinical examination, skin prick tests to common aeroallergens and metal salts, rest spirometry tests, X-ray, metacholine challenge and a single-blind, placebo controlled specific inhalation challenge tests with metals (or work-like conditions challenge tests) were performed. Results: In group A – in 9 cases we obtained positive results of specific inhalation challenge tests with metals (in 3 cases with nickel, in 4 cases with chromium, in 1 case with cobalt and in 1 case with manganese). Nine cases of metal-induced occupational asthma were recognized. In group B – only in one case we obtained positive results of work-like conditions challenge test (clinical and spirometry changes, eosinophil influx in induced sputum), which confirmed the diagnosis of occupational asthma. In most of examined welders (62%), pulmonary changes in chest X-ray images were noted. The statistical analysis revealed that working as a welder for more than 10 years is the coexisting factor of presence of chest X-ray changes (p- or q-type nodular changes or interstitial changes). Positive results of skin prick tests with metal salts were the coexisting factors of occupational asthma due to metals among examined group of welders. Conclusions: Specific inhalation challenge plays the key role in diagnostics of metal-induced asthma in welders. Pulmonary changes in chest X-ray were found in a significant percentage of examined welders.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2012, 25, 3; 242-250
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-Ray Diffraction Measurements for Riveted Joints. The Application of a Novel Methodology
Autorzy:
Gadalińska, E.
Kaniowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/97767.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
X-ray diffraction method
stress measurements
riveted joints
Opis:
The X-ray diffraction method is the best, widely available, non-destructive measurement method used to determine the residual and load stresses in crystalline materials. This method can be applied without any limitations to flat specimens. Depending on the equipment geometry, the type of material and geometry of the specimen, there are many limitations, restrictions and recommendations which have to be fulfilled to obtain reliable results. This was the reason for working out a methodology for X-ray diffraction stress measurements for riveted specimens.The first case to analyze is the necessity of choosing an X-ray tube suitable for the specimen material which will give the diffraction peaks in the range of 2Θ angles between 120° and 180°. Afterwards it is crucial to make the best selection of Bragg's angle 2Θ. In the vast majority of cases the best selection is the possibly biggest 2Θ angle because of the best accuracy of the measurement. However, for example for aluminum alloys (for CrKα radiation), this choice is not so obvious. It is much more convenient to perform measurements not for the highest diffraction angle. The best selection in this case is 2Θ=139,3°, and not 156,7°. Other selections which are necessary to be made before measurements are the collimator diameter, time of exposure, ψ tilts and φ oscillations. The proper selection of these parameters is crucial for the fast and efficient performing of measurements and for obtaining reliable results. Before performing the measurement, especially in the case of the specimen with complicated geometry (for example in the case of riveted specimens made of aluminum alloys), it is necessary to analyze the results obtained paying special attention to the possibility of the appearing of the rivet head/driven rivet head shadow during the measurement. The work describes differences between the X-ray stress measurement results obtained without any interference and the results received after eliminating the selected diffraction peaks for which the shadow of rivet head/driven rivet head has appeared.
Źródło:
Fatigue of Aircraft Structures; 2012, 4; 17-28
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on the X-ray wavelength division multiplexing technology for blackout region communication
Autorzy:
Li, Yao
Su, Tong
Sheng, Lizhi
Xu, Neng
Zhao, Baosheng
Powiązania:
https://bibliotekanauki.pl/articles/1835966.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
X-ray communication
plasma sheath
wavelength division multiplexing
Opis:
After the concept of X-ray communication was proposed, its application in complex electromagnetic environment has received more attention, such as data transmission in re-enter special electro-magnetic condition. In this article, a new type of X-ray source was introduced firstly, which was expected to generate multiple characteristic lines and achieve wavelength division multiplexing technology in X-ray band. Then an experimental platform was built for analyzing transmission characteristics of X-ray photon in various plasma media. Finally, the calculation model for a link power equation was given. Experiment results show that transmittance of 8–18 keV X-ray signal is relatively stable, atomic numbers from 29 to 42 are the most suitable materials for wavelength division multiplexing, the X-ray communication system is expected to realize about 200 kbps data transmission rate in adjacent space.
Źródło:
Optica Applicata; 2020, 50, 4; 619-632
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Residual stresses measurements with X-ray diffractometry on aluminum specimens - determination of the most suitable parameters of measurement
Autorzy:
Gadalińska, E.
Kaniowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/245743.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
X-ray diffractometry
residual stresses
fatigue
aluminum alloys
Opis:
The work was done as apart of the IMPERJA Eureka Project. The goal of the IMPERJA project is to increase the fatigue life of riveted joints, which will lead to an increase of the aircraft service life, a smaller number of inspections and lower operation costs of an aircraft. The consortium intends to meet this goal by investigating and improving the riveting process as well as improving the prediction methods for fatigue life. Riveting is the most commonly used method of joining sheet metal components of the aircraft structure. Typically, the number of rivets ranges from several thousands to some millions in a single aircraft depending on the specific aircraft type and size. The riveted joints are critical areas of the aircraft structure due to severe stress concentrations and effects such as fretting and secondary bending. Therefore the fatigue crack initiation will start at the rivets holes. Fatigue crack initiation usually occurs at a number of rivet holes (multiple site damage), which may lead to widespread fatigue damage and reduced residual strength. Although the literature on the fatigue behaviour of riveted joints is quite abundant, many aspects are still not sufficiently understood and investigated and, therefore, they require a further study. The work contains the results of stress measurements obtained with X-ray diffractometer. The aim of the work was to determine the stress values after different kinds of treatment, to check what are the limits of the x-ray measurement for aluminum alloys and to obtain the most suitable measurement parameters for this kind of alloy. There were 5 kinds of specimens: -specimen no. l - technically pure aluminum, specimen annealed in temperature 300° C for l hour, -specimen no. 2 - technically pure aluminum, raw state without any additional treatment, -    -specimen no. 3 - technically pure aluminum, squeezed perpendicularly to the axis direction, force: l00 kN, longitudinal intersection, specimen no. 4 - technically pure aluminum, squeezed perpendicularly to the axis direction, force: 100 kN, transverse intersection, specimen no. 5 - PA24 alloy, 05 bar, squeezed along the axis of the rod, force: l3,9 kN, longitudinal intersection. The second part of the work contains the measurements of the stress distribution around the rivets. The specimen prepared to realize this kind of measurements had four areas. The rivets on every area were riveted with the different riveting force: 1.2 kN; 1.4 kN; 1.5 kN and 1.55 kN.
Źródło:
Journal of KONES; 2009, 16, 4; 123-134
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Size/Strain Diffraction Peak Broadening of the Energetic Materials FOX-7, RDX and ADN
Autorzy:
Herrmann, M.
Forter-Barth, U.
Kempa, P. B.
Powiązania:
https://bibliotekanauki.pl/articles/358820.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
X-ray diffraction
microstructure
FOX-7
RDX
ADN
Opis:
X-ray powder diffraction (XRD) is an established tool for the investigation of energetic materials. Whereas positions and intensities of diffraction peaks yield information on the crystal structure, peak profles are related to the real structure described by crystallite size, shape and microstrain. A series of energetic materials were measured at the synchrotron ANKA, and the size/strain broadening of FOX-7, RDX and ADN is discussed in relation to crystal structures and properties.
Źródło:
Central European Journal of Energetic Materials; 2009, 6, 2; 183-193
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies