Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "x-ray" wg kryterium: Temat


Tytuł:
Review of X-ray detection systems
Autorzy:
Urbański, Paweł
Grzebyk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/27315700.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
X-ray detection
X-ray radiation
dosimetry
luminescence
Opis:
The article presents an overview and a classification of X-ray detection methods. The main motivation for its preparation was the need to select a suitable and useful method for detecting signals from a currently developed miniature micro-electro-mechanical system (MEMS) X-ray source. The described methods were divided into passive and active ones, among which can be distinguished: chemical, luminescent, thermo-luminescent, gas ionization, semiconductor, and calorimetric methods. The advantages and drawbacks of each method were underlined, as well as their usefulness for the characterisation of the miniature MEMS X-ray source.
Źródło:
Opto-Electronics Review; 2023, 31, 3; art. no. e146554
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wideband spectral emission measurements from laser-produced plasma EUV/SXR source based on a double gas puff target
Autorzy:
Arikkatt, Antony Jose
Wachulak, Przemysław
Fiedorowicz, Henryk
Bartnik, Andrzej
Czwartos, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1849155.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Plasma Spectroscopy
X-ray coherence tomography
soft X-ray
Opis:
We present spectral emission characteristics from laser-plasma EUV/SXR sources produced by irradiation of < 1 J energy laser pulse on eleven different double stream gas puff targets, with most intense electronic transitions identified in the spectral range from 1 nm to 70 nm wavelength which corresponds to photon energy from 18 eV to 1240 eV. The spectra were obtained using grazing incidence and transmission spectrographs from laser-produced plasma emission, formed by the interaction of a laser beam with a double stream gas puff target. Laser pulses with a duration of 4 ns and energy of 650 mJ were used for the experiment. We present the results obtained from three different spectrometers in the wavelength ranges of SXR (1-5.5 nm), SXR/EUV (4-15.5 nm), and EUV (10-70 nm). In this paper, detailed information about the source, gas targets under investigation, the experimental setup, spectral measurements and the results are presented and discussed. Such data may be useful for the identification of adequate spectral emissions from gasses in the EUV and SXR wavelength ranges dedicated to various experiments (i.e. broadband emission for the X-ray coherence tomography XCT) or may be used for verification of magnetohydrodynamic plasma codes.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 701-719
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
$K_{β}/K_{α}$ X-Ray Intensity Ratios for Cr, Mn, Fe, and Co Excited by 8.735 keV Energy
Autorzy:
Yılmaz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1398200.pdf
Data publikacji:
2018-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
K X-ray intensity ratios
X-ray fluorescence
cross-sections
Opis:
In this study, the K shell intensity ratios $K_{β}/K_{α}$ have been experimentally determined for the elements Cr, Mn, Fe, and Co. Measurements have been carried out at 8.735 keV excitation energy by using secondary excitation method. K X-rays emitted by samples have been counted by a Si (Li) detector with 160 eV resolutions at 5.9 keV. The measured values were compared with the calculated theoretical values. The obtained values are in good agreement with the calculated values.
Źródło:
Acta Physica Polonica A; 2018, 133, 5; 1227-1230
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar czasu ekspozycji w miernikach promieniowania rentgenowskiego
Measurement of exposure duration in the X-ray analyser
Autorzy:
Urban, Arkadiusz
Czubla, Albin
Knyziak, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/88863.pdf
Data publikacji:
2020
Wydawca:
Główny Urząd Miar
Tematy:
pomiar czasu ekspozycji
promieniowanie X
aparat rentgenowski
exposure time measurement
X-ray
X-ray machine
X-ray multimeter
Opis:
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na błąd pomiaru.
The main idea of the article is a description of problems of X-ray exposure time measurement. The content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time are presented. It also discusses the impact of different resolution settings of device under calibration on uncertainty measurement.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2020, 1 (24); 15-20
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X pinch as a source for X-ray radiography
Autorzy:
Pikuz, S.
Shelkovenko, T.
Romanova, V.
Sinars, D.
Hammer, D.
Bland, S.
Lebedev, S.
Powiązania:
https://bibliotekanauki.pl/articles/147532.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
wire array
X-pinch
X-ray imaging
X-ray radiography
Z-pinch
Opis:
This article describes several applications and methods using the X pinch as a source of X-ray radiation for the radiography of dense plasma objects. These methods, in general, do not use pinholes, and instead take the advantage of the small size (<1 mm, and in some cases <3 mm) and a short X-ray emission duration (<1 ns) of the radiation source produced by an X pinch. Two of these methods, monochromatic and direct point-projection backlighting, are discussed. Experimental images of exploding wires and wire arrays obtained on the BIN, XP, and MAGPIE generators using these techniques are presented. Also included are detailed measurements made on the XP generator of the emission characteristics of X pinches using different wire materials.
Źródło:
Nukleonika; 2001, 46, 1; 21-25
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorcowanie funkcji pomiaru czasu ekspozycji w miernikach promieniowania rentgenowskiego
Calibration of exposure duration in the X-ray analyser
Autorzy:
Urban, Arkadiusz
Czubla, Albin
Knyziak, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/268140.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wzorcowanie miernika promieniowania X
pomiar czasu ekspozycji
promieniowanie X
aparat rentgenowski
calibration
exposure time measurement
X-ray
X-ray machine
X-ray multimeter
Opis:
W artykule opisano problematykę pomiarów przedziałów czasu równych czasowi ekspozycji promieniowania X. Pokazano zależność niepewności pomiaru od metody pomiarowej oraz od sposobu działania źródła promieniowania rentgenowskiego. Przedstawiono wpływ zakresu przedziału czasu mierzonego przez miernik na wielkość błędu.
Main idea of the article is a description of problems of X-ray exposure time measurement. Content describes two types of X-ray machines. Among the two X-ray machine types, continuous type with shutter is more suitable for long time measurement, and pulse type is better for short time measurements. The article discuss differences between mode of operation of different X-ray sources and it’s impact on uncertainty of measurement of exposure time. It also discuss impact of different resolution settings of device under calibration on uncertainty measurement.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 91-94
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent measurements of soft X-ray emission from the DPF-1000U facility
Autorzy:
Surała, W.
Sadowski, M. J.
Paduch, M.
Zielinska, E.
Tomaszewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/148171.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray emission
X-ray images
gas puffing
filaments
hot spots
Opis:
Soft X-ray imaging is a very useful diagnostic technique in plasma-focus (PF) experiments. This paper reports results of four experimental sessions which were carried out at the DPF-1000U plasma-focus facility in 2013 and 2014. Over 200 discharges were performed at various experimental conditions. Measurements were taken using two X-ray pinhole cameras with a line of sight perpendicular to the z-axis, at different azimuthal angles (about 20° and 200°), and looking towards the centre of the PF-pinch column. They were equipped with diaphragms 1000 μm or 200–300 μm in diameter and coated with filters of 500 μm Al foil and 10 μm Be foil, respectively. Data on the neutron emission were collected with silver activation counters. For time-resolved measurements the use was made of four PIN diodes equipped with various fi lters and oriented towards the centre of the PF-column, in the direction perpendicular to the electrode axis. The recorded X-ray images revealed that when the additional gas-puff system is activated during the discharge, the stability of the discharge is improved. The data collected in these experiments confi rmed the appearance of a filamentary fi ne structure in the PF discharges. In the past years the formation of such fi laments was observed in many Z-pinch type experiments. Some of the recorded X-ray images have also revealed the appearance of the so-called hot- -spots, i.e. small plasma regions of a very intense X-ray emission. Such a phenomenon was observed before in many PF experiments, e.g. in the MAJA-PF device, but it has not been investigated so far in a large facility such as the DPF-1000U. The time-resolved measurements provided the evidence of a time lapse between the X-ray emission from plasma regions located at different distance from the anode surface. The formation of distinct ‘hot-spots’ in different instants of the DPF-1000U discharge was also observed.
Źródło:
Nukleonika; 2015, 60, 2; 303-308
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High speed signal processing for photon counting X-ray detection
Autorzy:
Shinomiya, B.
Koike, A.
Morii, H.
Okunoyama, T.
Neo, Y.
Mimura, H.
Aoki, T.
Powiązania:
https://bibliotekanauki.pl/articles/385292.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
X-ray
CdTe
photon counting
Opis:
Recently practical X-ray measurement systems are demanded energy distinction function. Photon-counting CdTe semiconductor detectors have a high energy resolution in a low count rate condition at room temperature. However, the energy resolution is decreased by pile-up phenomenon in a high count rate condition. In conventional signal processing, processing time estimated X-ray photon energy from the pulse waveform is about tens of microseconds. This time is depended on the pulse decay time. This paper purposes to maintain the high energy resolution by changing the signal-processing algorithm, which derived the pulse rise height of the output waveform from the CdTe detector in a high count rate condition. As a result, the pulse rise time required to estimate the pulse rise height was short about 100 ns at incident X-ray energy 60 keV. As the result of energy spectrum by using this data, the FWHM of about 11keV (at 60 keV) when the count rate of 500 kcps. This result shows the possibility that the photon counting sensor has application for the high count rate imaging without decrease of the high energy resolution.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 143-146
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study on X-ray source from Plasma Focus device for fast radiography
Autorzy:
Da Re, A.
Mezzetti, F.
Tartari, A.
Verri, G.
Rapezzi, L.
Gribkov, V. A.
Powiązania:
https://bibliotekanauki.pl/articles/147243.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray sources
Opis:
Plasma derived flash X-ray sources may find potential applications in medicine and industry. Notwithstanding, as is the case of Plasma Focus (PF) devices, their characterisation in term of photon energy, temporal and spatial beam stability is far to be considered satisfactory. In this work, a radiographic approach, which avoids the effects caused by the intrinsic instability of the pinch output of a PF machine, is proposed and an attenuation curve can be attained even in presence of Xray emission instability. Using two radiographic films for each shot exposition symmetrically positioned and collimated to the pinch region the mean energy of the photons in the X-ray beam are evaluated. The X-ray emission symmetry from the pinch region was then utilised to control the validity of the proposed methodology.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 123-125
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray techniques in the investigation of a Gothic sculpture : the risen Christ
Autorzy:
Mikołajska, A.
Walczak, M.
Kaszowska, Z.
Urbańczyk-Zawadzka, M.
Powiązania:
https://bibliotekanauki.pl/articles/146866.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cultural heritage
X-ray image
X-ray dual source computed tomography (DSCT)
scanning electron microscopy energy dispersed X-ray spectroscopy (SEM-EDX)
Opis:
For over a century, X-ray radiation has played an important role in the area of the conservation and restoration of cultural heritage objects. X-ray techniques are amongst the most fundamental and helpful methods used in the investigation of art works. This paper reviews the application of traditional radiography, X-ray dual source computed tomography (DSCT) and scanning electron microscopy combined with energy dispersed X-ray spectroscopy (SEM-EDX) to the investigation of a wooden, Gothic sculpture, The risen Christ. Thanks to the properties of X-ray radiation (different absorption by various materials) first two methods allow the assessment of the preservation state and the observation of the internal structure of an object in 3-D. While SEM-EDX analysis permits the elemental analysis of the polychrome layers. As a result 2-D and 3-D images, permitting the full volume inspection of an object, were taken in a totally non-destructive way. The morphological and physical information about the inner structure of the investigated wooden sculpture was obtained, revealing changes related to previous restorations, as well as ageing effects. Employing the SEM-EDX, painting materials (pigments and filers), were identified. Gained data is essential for restorers to understand the whole structure of the studied object and to decide which further investigation and restoration steps have to be undertaken.
Źródło:
Nukleonika; 2012, 57, 4; 627-631
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dense Plasma Focus as a powerful source of monochromatic X-ray radiation
Autorzy:
Dubrovsky, A.
Gribkov, V.
Ivanov, Y.
Karpiński, L.
Orlova, M.
Powiązania:
https://bibliotekanauki.pl/articles/147444.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
X-ray generation
X-ray dosimetry
exposure dose
absorbed dose
Opis:
A review of some experimental results obtained using the dense plasma focus (DPF) device PF-1000 is presented. The copper Ka1,2 radiation line generated by DPF in the case of device anode made of copper was the main object of this study. The predominance of this characteristic radiation over other kinds of radiation in the DPF X-ray spectrum is shown. A brief description of a new DPF 6.0 device as well as a radioenzymology experiment carried out within this device is presented.
Źródło:
Nukleonika; 2006, 51, 1; 21-28
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of the soft X-ray tungsten spectra expected to be registered by GEM detection system for WEST
Autorzy:
Syrocki, Ł.
Szymańska, E.
Słabkowska, K.
Polasik, M.
Pestka, G.
Powiązania:
https://bibliotekanauki.pl/articles/971490.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
X-ray spectra
tokamak
tungsten L, M, N, X-ray lines
GEM detection system
Opis:
In the future International Thermonuclear Experimental Reactor (ITER), the interaction between the plasma and the tungsten chosen as the plasma-facing wall material imposes that the hot central plasma loses energy by X-ray emission from tungsten ions. On the other hand, the registered X-ray spectra provide alternative diagnostics of the plasma itself. Highly ionized tungsten emits extremely complex X-ray spectra that can be understood only after exhaustive theoretical studies. The detailed analyses will be useful for proper interpretation of soft X-ray plasma radiation expected to be registered on ITER-like machines, that is, Tungsten (W) Environment in Steady-state Tokamak (WEST). The simulations of the soft X-ray spectra structures for tungsten ions have been performed using the flexible atomic code (FAC) package within the framework of collisional-radiative (CR) model approach for electron temperatures and densities relevant to WEST tokamak.
Źródło:
Nukleonika; 2016, 61, 4; 433-436
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and Characterization of Co-Cs-Nd-Sr-Doped Perovskite-Rutile-Type Structure
Autorzy:
Smolinski, T.
Zhao, L.
Rogowski, M.
Wawszczak, D.
Olczak, T.
Brykala, M.
Powiązania:
https://bibliotekanauki.pl/articles/355628.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Synroc
X-ray diffraction
Rutherford backscattering
particle induced X-ray emission
Roentgen computed microtomography
Opis:
The perovskite type matrix is considered as solidification material for high-level radioactive waste. In this work the perovskite-rutile-type matrix doped by Co, Cs, Nd and Sr which simulate nuclear waste was prepared by sol-gel route. The material was characterized by several methods such as: X-ray diffraction, energy dispersive X-ray spectrometer, and particle induced X-ray emission combined with Rutherford backscattering spectrometry. The analyzes confirmed chemical composition Co-Cs-Nd-Sr-doped perovskite-rutile-type structure. A virtual model of the pellet`s structure was created non-destructively by Roentgen computed micro-tomography. The leaching tests confirmed high chemical resistance of the matrix.
Źródło:
Archives of Metallurgy and Materials; 2020, 65, 4; 1417-1423
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray tube with needle-like anode
Autorzy:
Słapa, M.
Straś, W.
Traczyk, M.
Dora, J.
Snopek, M.
Gutowski, R.
Drabik, W.
Powiązania:
https://bibliotekanauki.pl/articles/147038.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
brachytherapy
photon needle
X-ray tube
Opis:
An X-ray tube with a needle-like anode (NAXT) built in our Laboratory, its design and basic operating parameters are presented. The process of electron beam forming and influence of external and internal magnetic fields is discussed. The tube properties essential from the point of view of its application in X-ray generators as well as disadvantageous thermal effects caused by flow of heat generated in the tube target to irradiated objects are discussed. The tube is almost a point-like source of X radiation emitted into 4đ geometry; the dose rates are on the order of 1 Gy/min at the distance of 10 mm from the anode cap. Preliminary tests show the tube may be useful in brachytherapy of cancer tumors of diameter up to 30 mm. The tube may also be an interesting device in widely understood field of irradiation techniques.
Źródło:
Nukleonika; 2002, 47, 3; 101-105
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multichannel calorimeters for measurement of flows of X-ray radiation in the range from 10 up to 200 keV
Autorzy:
Vinogradov, V. P.
Powiązania:
https://bibliotekanauki.pl/articles/148228.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
calorimeter
hard X-ray
plasma focus
Opis:
An 8-channel calorimeter was developed and applied to the Plasma focus facility (PF) with flat geometry of electrodes (Filippov type) for the measurements of a hard X-ray (HXR) radiation yield and its spectral distribution. The calorimeter measures the time-integrated HXR flux for one shot of the PF facility without any additional calibrations. The sensitivity ~10–4 J/cm2 was achieved.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 99-101
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure data at 150 K for diammonium oxalate monohydrate, [NH4]2[C2O4][H2O]
Autorzy:
Mielniczek-Brzóska, E.
Dmytriv, G.
Pavlyuk, V.
Griffin, A.
Powiązania:
https://bibliotekanauki.pl/articles/410252.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
oxalates
crystal structure
X-ray diffraction
Opis:
The single crystals of perfectly quality of the diammonium oxalate monohydrate, [NH4]2[C2O4][H2O], were obtained by the improved methods of crystal growth from solution. The crystal structure of title compound was studied at 150 K using modern X-ray equipment. At this temperature, as well as at room temperature, this compound crystallizes in the orthorhombic symmetry wiith P21212 space group. The unit cell of the title compound is formed by four amonium cations, two oxalate anions and water molecules, with a 2:1:1 cation-anion-water ratio. At 150 K oxalate ion is twisted by 26.9 (1)°. The similar twist angle (26.6 (4)° was observed at the room temperature. Central carbon-carbon bond in oxalate ion is insignificantly longer (1.568 Å) in comparing with this bond at room temperature (1.559 Å).
Źródło:
Chemistry, Environment, Biotechnology; 2013, 16; 73-78
2083-7097
Pojawia się w:
Chemistry, Environment, Biotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantitative Characteristic X-Ray Analysis for Different Compound Samples by Using Monte Carlo Method
Autorzy:
Tekın, H.
Altunsoy, E.
Manici, T.
Yilmaz, B.
Powiązania:
https://bibliotekanauki.pl/articles/1030113.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Monte Carlo
characteristic X-ray
brass
Opis:
X-ray spectrometry is an elemental analysis technique with broad application in science and industry. It is based on the principle that individual atoms, when excited by an external energy source emit X-ray photons of a characteristic energy or wavelength. Here we obtained the characteristic X-ray peaks of different brass compounds and compared the intensity of characteristic peaks by changing with Zn rate. In this study we modelled different brass samples by using Monte Carlo method and changed the zinc rate in brass samples for each compound. We obtained the characteristic X-ray peaks of different compounds and compared the intensity of characteristic peaks by changing with Zn rate. We achieved a good agreement between peak intensity and corresponding element rate in compound. Also we obtained that characteristic peak rate increases by corresponding element rate in compound. This study shows that Monte Carlo method is very effective method to simulate material features due to their characteristic peaks and their intensities.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 439-441
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
57Fe Mössbauer spectroscopy and X-ray diffraction study of gadolinites REE2Fe2+Be2Si2O10 from Lower Silesia (Poland) and Ytterby (Sweden)
Autorzy:
Malczewski, D.
Powiązania:
https://bibliotekanauki.pl/articles/148858.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
gadolinite
Mössbauer spectroscopy
X-ray diffraction
Opis:
This paper reports the results of 57Fe Mössbauer spectroscopy, X-ray diffraction (XRD) and gamma-ray spectroscopy studies of partially metamict gadolinites from Szklarska Poręba and Zimnik (Lower Silesia, Poland), a fully metamict gadolinite sample from Ytterby (Sweden) and a crystalline sample obtained after annealing of a fragment of the sample from Ytterby at 1373 K in an argon atmosphere. Both fully metamict and crystalline gadolinite show divalent iron exclusively in octahedral coordination. Changes of the amplitudes ratio of high energy to low energy absorption peaks from Fe2+ quadrupole doublets are strictly correlated with calculated absorbed alpha-dose and the metamictization stages of the gadolinite specimens. In this respect, one of the samples is in conflict with the estimated radiation dose based on age and radionuclide concentrations. In this case, Mössbauer spectroscopy shows that the sample had to be naturally annealed over geologic time.
Źródło:
Nukleonika; 2003, 48,suppl.1; 41-44
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conceptual design of Light Impurity Monitor for Wendelstein 7-X
Autorzy:
Książek, I.
Burhenn, R.
Musielok, J.
Powiązania:
https://bibliotekanauki.pl/articles/146640.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma spectroscopy
stellarator
soft X-ray
Opis:
As plasma impurity ions can significantly influence the properties of a fusion plasma by dilution and enhancement of the radiation losses, the process of monitoring of their concentrations is one of the most important tasks. A Light Impurity Monitor is needed for monitoring the contamination of the stellarator plasma by carbon, nitrogen, boron, and oxygen impurities, which are indicators for the overload of the plasma facing components, leakage of the vacuum vessel, or wall condition, respectively. Their concentration will be estimated on the basis of emission intensities of their hydrogen-like ions. In this paper a conceptual design of such a spectrometer is presented, including the description of the geometry, the acquisition system and safety systems.
Źródło:
Nukleonika; 2011, 56, 2; 155-160
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Behavior of Jordanian Oil Shale during Combustion Process from the El-Lajjun Deposit
Autorzy:
Gougazeh, Mousa
Alsaqoor, Sameh
Borowski, Gabriel
Alsafasfeh, Ashraf
Hdaib, Ismail I.
Powiązania:
https://bibliotekanauki.pl/articles/2173323.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
El-Lajjun oil shale
combustion
X-ray diffraction
thermogravimetric
fourier transform infrared spectroscopy
X-ray fluorescence
Opis:
The results of X-ray diffraction, thermogravimetric and FTIR spectroscopy analyses of mineral composition indicated that the El-Lajjun oil shale is principally composed of calcite, quartz with minor amounts of kaolinite), gypsum, and apatite. The obtained oil shale ash products at 830 °C and 1030 °C are dominated by lime, quartz, anhydrite, portlandite, gehlenite, and amorphous phases. The TGA weight loss curves clearly indicate that it occurred in the temperature range from 310 to 650 °C. The decomposition of oil shale carbonates was detected above 750°C. The functional groups in the organic material of oil shale are dominated by the aliphatic hydrocarbons, the semi-ash of which had diverse structures of polycyclic aromatic hydrocarbons. The most intensive of combustion occurred in the temperature range of 400–750 °C. In this temperature range, about 75 wt.% was accounted for the total mass loss.
Źródło:
Journal of Ecological Engineering; 2022, 23, 8; 133--140
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The concept of implementation of a clinical audit as a tool for evaluating quality management in X-ray diagnostics
Koncepcja realizacji audytu klinicznego jako narzędzia do oceny poziomu zarządzania jakością w rentgenodiagnostyce
Autorzy:
Sergot, M.
Powiązania:
https://bibliotekanauki.pl/articles/202713.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
clinical audit
management
quality
X-ray imaging
X-ray facilities
audyt kliniczny
zarządzanie
jakość
rentgenodiagnostyka
pracownia rtg
Opis:
The article discusses the clinical implementation of internal audits in enterprises that use ionizing radiation in X-ray diagnostics. The legal aspects involved in conducting clinical audits and their implementation are presented. Rules which have to be obeyed during an audit of a quality management system are compared in an analysis with the rules accommodated during a clinical audit led by state authorities. This analysis presents some similarities between the analyzed forms of checking the management system’s condition in X-ray diagnostics. In addition to similarities, there exist some differences also, and they are pointed out in this analysis, that is, elements that distinguish the audits from each other. Both a quality management system’s audit and control components can be used for a clinical audit. The author designed a simple workflow during the internal clinical audit. The conclusions of the analysis will be the subject of further research.
W artykule opisano problem wdrożenia wewnętrznych audytów klinicznych w przedsiębiorstwach wykorzystujących promieniowanie jonizujące w rentgenodiagnostyce. Przywołano prawne aspekty przeprowadzania audytów klinicznych oraz ich wdrażania. Dokonano analizy porównawczej reguł przeprowadzania audytów systemu zarządzania jakością z regułami przeprowadzania audytów klinicznych i regułami przeprowadzania kontroli organów państwowych. W konsekwencji tej analizy wskazano podobieństwa pomiędzy analizowanymi formami sprawdzania stanu systemu zarządzania w rentgenodiagnostyce. Zwrócono również uwagę na elementy odróżniające je od siebie, a także możliwość adaptacji elementów audytu systemu zarządzania jakością i elementów kontroli organów państwowych na rzecz audytu klinicznego. Opracowano prosty schemat postępowania podczas wewnętrznego audytu klinicznego. Wnioski z przeprowadzonej analizy stanowić będą przedmiot dalszych badań.
Źródło:
Zeszyty Naukowe Politechniki Poznańskiej. Organizacja i Zarządzanie; 2016, 69; 81-96
0239-9415
Pojawia się w:
Zeszyty Naukowe Politechniki Poznańskiej. Organizacja i Zarządzanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezgodności z wymogami ochrony radiologicznej występujące w rentgenodiagnostyce oraz propozycje ich usunięcia
Radiodiagnostics and inconsistencies with the requirements of radiological protection along with propositions for their elimination
Autorzy:
Sergot, M.
Powiązania:
https://bibliotekanauki.pl/articles/179082.pdf
Data publikacji:
2017
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ochrona radiologiczna
promieniowanie jonizujące
rentgenodiagnostyka
bezpieczeństwo rtg
radiological protection
ionizing radiation
X-ray diagnostics
X-ray safety
Opis:
W artykule zaprezentowano podstawową problematykę z zakresu ochrony radiologicznej. Została również przeanalizowana aktualna sytuacja dotycząca niezgodności występujących podczas organizacji bezpieczeństwa pracy przy promieniowaniu rentgenowskim. Celem artykułu było opracowanie rozwiązania występujących niezgodności. Aby osiągnąć przedstawiony cel zaproponowano zmiany, które mogą mieć istotny wpływ na poprawę poziomu bezpieczeństwa pracowników na wybranym stanowisku oraz pacjentów. Dokonano analizy literatury z zakresu negatywnego oddziaływania promieniowania rentgenowskiego na organizm człowieka. Podzielono tak ze istniejące środki ochrony ze względu na osłonę dla pacjenta i pracownika oraz ogół ludności. Wykonano badania w 33 jednostkach ochrony zdrowia w celu weryfikacji stosowanej ochrony radiologicznej i niezgodności z nią związanych.
This article discusses some basic issues in radiological protection. It also analyzes problems in occupational safety related to X-rays. To solve those problems, it necessary to introduce several changes, which could significantly improve the level of safety of workers at selected workstations and patients. This article presents an analysis of the literature on the negative impact X-rays have on the human body, rays and a classification of existing safety measures according to whether they protect patients, personnel or the general population. To verify inconsistencies with the requirements of radiological protection, measurements were conducted at 33 health care facilities.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2017, 5; 11-15
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Second order reflection from crystals used in soft X-ray spectroscopy
Autorzy:
Książek, I.
Powiązania:
https://bibliotekanauki.pl/articles/146093.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
plasma spectroscopy
PbSt
KAP
Opis:
In this note the ratio of the second to the first order reflection is determined for the KAP and PbSt crystals, for wavelengths corresponding to the Al K-line emission. The source of the radiation was a low-voltage stabilized X-ray tube. The X-rays were detected with a Bragg spectrometer equipped with a proportional counter detector. The signal measured by the proportional counter was subsequently pulse height analyzed.
Źródło:
Nukleonika; 2015, 60, 2; 263-265
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of soft X-ray tomography on the COMPASS tokamak
Autorzy:
Imríšek, M.
Mlynář, J.
Löffelmann, V.
Weinzettl, V.
Odstrčil, T.
Odstrčil, M.
Tomeš, M.
Powiązania:
https://bibliotekanauki.pl/articles/146251.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
tomography
Tikhonov regularization
tokamak
Opis:
The COMPASS tokamak is equipped with the soft X-ray (SXR) diagnostic system based on silicon photodiode arrays shielded by a thin beryllium foil. The diagnostic is composed of two pinhole cameras having 35 channels each and one vertical pinhole camera with 20 channels, which was installed recently to improve tomographic inversions. Lines of sight of the SXR detectors cover almost complete poloidal cross section of the COMPASS vessel with a spatial resolution of 1–2 cm and temporal resolution of about 3 s. Local emissivity is reconstructed via Tikhonov regularization constrained by minimum Fisher information that provides reliable and robust solution despite limited number of projections and ill-conditionality of this task. Improved border conditions and numerical differentiation matrices suppressing artifacts in reconstructed radiation were implemented in the code. Furthermore, a fast algorithm eliminating iterative processes was developed, and it is foreseen to be tested in real-time plasma control.
Źródło:
Nukleonika; 2016, 61, 4; 403-408
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy transformation in Plasma Focus discharge with wire and liner as a load
Autorzy:
Kubeš, P.
Kravárik, J.
Klír, D.
Scholz, M.
Paduch, M.
Tomaszewski, K.
Karpinski, L.
Ryc, L.
Juha, L.
Krasa, J.
Szydlowski, A.
Romanova, V.
Powiązania:
https://bibliotekanauki.pl/articles/147107.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
X-ray source
XUV spectroscopy
Opis:
We present the results of experiments focused on energy transformations during the implosion of the hydrogen current sheath towards an Al wire (120 ěm in diameter) positioned on the top of the inner electrode of the PF-1000 plasma focus facility at the IPPLM in Warsaw. A wire corona is formed at the current sheath impact and ~60 ns after the impact a soft X-ray pulse is emitted. Its spectrum contains AlVI-XII lines accompanied by their satellites. The amount of emitted energy is recorded by two filtered PIN diodes and thermoluminescent dosimeters and depends on symmetry of the current sheath and quality of the current sheath focus. The mean value of energy of keV photons emitted in the runs done without the wire (~1 J) is higher than the energy obtained with the wire (~0.4 J). A time delay between the impact of the current sheath and X-ray pulse, the plasma focus dynamics and soft X-ray emission are interpreted by an axial magnetic field generation and transformations.
Źródło:
Nukleonika; 2002, 47, 4; 151-153
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies