Tytuł:
High temperature heat pumps technology for geothermal district heating applications
Technologia wysokotemperaturowych pomp ciepła dla ciepłownictwa sieciowego w zastosowaniach geotermalnych
Autorzy:
Wojtan, L.
Powiązania:
https://bibliotekanauki.pl/articles/203831.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
pompy ciepła wysokotemperaturowe
ciepłownictwo sieciowe
pompy ciepła sprężarkowe
odśrodkowe pompy ciepła
woda gruntowa
woda geotermalna
zbiornik wodonośny neokomu
zbiornik wodonośny doggeru
high temperature heat pumps
district heating
centrifugal compressor
ground water
geothermal water
Neocomian aquifer
Dogger aquifer
Opis:
Already since more than three decades high capacity centrifugal heat pumps are reducing CO2 emissions and are supplying hot water up to 90°C to district heating systems. In most cases the heat is recovered from low temperature heat sources like waste, river and sea water. However, with the centrifugal heat pump technology energy can also be exploited from high temperature heat sources like geothermal water. With an intelligent heat pump system the district heating return temperature can be boosted and at the same time the exploitation of the geothermal heat source can be increased. In this paper four examples of large centrifugal heat pumps in district heating applications using ground, water from the Neocomian and Dogger aquifers will be presented. The heating capacity of presented examples ranges from 5'000 to 8'650 kW.
Już od ponad trzech dziesięcioleci odśrodkowe pompy ciepła zasilają sieci ciepłownicze wodą o temperaturach do 90°C, przyczyniając się do znacznej redukcji emisji CO2. W większości przypadków do odzysku ciepła używane są niskotemperaturowe źródła ciepła, takie jak ścieki, woda rzeczna bądź morska. Jednakże przy użyciu technologii odśrodkowych pomp ciepła mogą być również eksploatowane inne dolne źródła ciepła, takie jak woda geotermalna. Zastosowanie inteligentnego systemu pompy ciepła umożliwia podwyższenie temperatury powrotu sieci ciepłowniczej do wymaganego poziomu przy jednoczesnym zwiększeniu eksploatacji źródła geotermalnego. Artykuł prezentuje cztery przykłady zastosowań odśrodkowych pomp ciepła dużej mocy w aplikacjach ciepłowniczych używających wody gruntowej ze zbiorników w utworach jurajskich (neokomu i doggeru). Moc cieplna użytych urządzeń waha się w zakresie od 5 000 do 8 650 kW.
Źródło:
Technika Poszukiwań Geologicznych; 2013, R. 52, nr 1, 1; 161-170
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and Economic Analysis of The Use of Heat Pumps in a Public Facility
Autorzy:
Wiekiera, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/27314842.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
air-water heat pump
ground-water heat pump
heat pumps
RES
pompy ciepła powietrze-woda
pompa ciepła grunt-woda
pompy ciepła
OZE
Opis:
A heat pump uses natural energy from renewable sources such as air, ground or water. The pump, acquiring thermal energy from the environment (75%) and using electricity (25%), supplies it to the heated object. A heat pump-based system consists of a ground heat source (heat is taken from it), a heat pump unit and an upper heat source (heat is transferred to it). The refrigerant transfers heat from the lower heat source to the upper heat source. The paper discusses types of heat pumps in terms of the use of the lower heat source. A technical and economic analysis was carried out on the basis of two types of heat pump: air-to-water and ground-to-water A comparative analysis of the results obtained results will allow a real assessment of the system’s functioning.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 4; 376--388
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena techniczno-ekonomiczna systemów grzewczych w budynku o niemal zerowym zużyciu energii współpracujących z mikroinstalacją fotowoltaiczną
Technical and economic evaluation of heating systems in a nearly zero energy building cooperating with a photovoltaic microinstalation
Autorzy:
Szul, Tomasz
Kokoszka, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/946857.pdf
Data publikacji:
2020-06-30
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
zużycie energii końcowej w budynku
budynek o niemal zerowym zużyciu energii
pompy ciepła typu powietrze/woda
pa-nele grzewcze
mikroinstalacja PV
analiza ekonomiczna
koszty cyklu życia LCC
final energy consumption in a building
nearly zero energy building
air/water heat pumps
heating panels
PV microin-stallation
economic analysis
LCC life cycle costs
Opis:
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zapotrzebowanie na moc i sezonowe zużycie energii do ogrzewania i przygotowania ciepłej wody użytkowej, określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.). Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów do-tyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną zgodnie z metodą opartą na kosztach cyklu życia LCC. Jako poziom odniesienia przyjęto budynek, w którym ogrzewanie i przygotowanie ciepłej wody użytkowej odbywa się za pomocą kotła gazowego kondensacyjnego, natomiast instalacja PV służy do pokrycia zapotrzebowania na energię elektryczną w budynku. Do analizy porównawczej przyjęto dwa systemy grzewcze, tj. pompę ciepła typu powietrze/woda oraz panele grzewcze. W tym przypadku instalacja PV miała pokryć wszystkie potrzeby energetyczne w budynku. W celu określenia zasadności montażu instalacji fotowoltaicznej służącej do pokrycia potrzeb energetycznych budynku dla poszczególnych wariantów, wykonano analizę ekonomiczną w oparciu o koszty cyklu życia LCC. Wyniki analizy wskazały, że lepszym wyborem dla inwestora będzie, jeżeli zdecyduje się na montaż systemu ogrzewania opartego na panelach grzewczych, m.in. ze względu na najkrótszy okres zwrotu nakładów inwestycyjnych.
For an exemplary single-family residential building, the power demand and seasonal energy consumption for heating and domestic hot water preparation were calculated, and the amount of electricity consumption for domestic purposes was also determined on the basis of statistical summaries. On this basis, the power was selected and the annual production volume of the photovoltaic microinstallation operating in the ON-GIRD system was determined under the Prospectus Reg-ulations of the Renewable Energy Sources Act. An economic analysis was then carried out based on methods based on LCC life cycle costs. A building where heating and domestic hot water preparation is carried out by means of a condens-ing gas boiler, while a photovoltaic installation serves to cover the electricity demand of the building was taken as a reference. Two heating systems were used for the comparison analysis, i.e. the air-water heat pump and the heating panels. In this case, the PV installation was to cover all energy needs in the building. In order to determine the validity of in-stalling a photovoltaic installation to cover the energy needs of the building for each variant, an economic analysis based on LCC life cycle costs was performed. The results of the analysis showed that a better choice for the investor will be if he decides to install a heating system based on heating panels, among others because of the shortest period of return on investment.
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2020, 1; 13-17
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka energetyczna budynków wiejskich powstałych przed rokiem 1918
Energy performance of buildings in rural areas built before 1918
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/884469.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
budynki wiejskie
budynki powstale przed rokiem 1918
charakterystyka energetyczna
wspolczynnik przenikania ciepla
zapotrzebowanie na energie
ogrzewanie
woda ciepla uzytkowa
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2015, 3
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena techniczno-ekonomiczna źródeł ciepła do przygotowania ciepłej wody użytkowej
Evaluation of technical and economic sources for the preparation of hot water
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/336100.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
ocena techniczno-ekonomiczna
ciepło
ciepła woda użytkowa
evaluation of technical and economic
preparation of hot water
Opis:
W pracy przedstawiono analizę porównawczą pięciu systemów do przygotowania c.w.u dla czteroosobowej rodziny. Są nimi, elektryczny podgrzewacz pojemnościowy, gazowy podgrzewacz pojemnościowy, pompa ciepła typu powietrze-woda oraz dwa zestawy solarne z kolektorem płaskim oraz próżniowym. Aby móc wybrać najkorzystniejszy obliczono zużycie energii końcowej do przygotowania ciepłej wody użytkowej a następnie przeprowadzono analizę techniczno-ekonomiczną w oparciu o metody dynamiczne takie jak LCC, PBP, NPV oraz IRR. W wyniku przeprowadzonych obliczeń wyłoniono system, który w perspektywie założonego 20-letniego okresu eksploatacji cechuje się najlepszymi wskaźnikami ekonomicznymi, a więc całkowite koszty przygotowania ciepłej wody użytkowej dla tego systemu będą najniższe. Najlepszym rozwiązaniem jest zastosowanie gazowego pojemnościowego ogrzewacza c.w.u, dla którego wartości wskaźników są najkorzystniejsze, a co najważniejsze inwestycja ta zwróci się po 4 latach. Zastosowanie pompy ciepła i zestawu solarnego z kolektorami płaskimi jest również dobrym rozwiązaniem jednak inwestycja w te urządzenia zwróci się dopiero po upływie 13-14 lat.
The paper presents a comparative analysis of five systems for hot water for a family of four. To select the best possible final energy consumption was calculated for the hot water and then carried out technical and economic analysis based on dynamic methods, such as LCC, PBP, NPV and IRR. As a result of the calculations it has been selected the system, which in the perspective of admitted 20-year period of use is characterized by the best economic indicators. Total costs of hot water for this system are the lowest. The best solution is to use a gas hot water heater capacitance, for which the index values are the best, and most importantly, this investment will return after 4 years. Application of heat pumps and solar set with flat collectors is a good solution, however, investment in these devices will return only after 13-14 years.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2011, 56, 2; 161-164
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and economic evaluation of a heating system based on air-to-water heat pumps with photovoltaic - micro-installation within the Prosument program
Ocena techniczno-ekonomiczna systemu grzewczego opartego na pompach ciepła typu powietrze woda współpracującego z mikroinstalacją fotowoltaiczną w ramach programu Prosument
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/334685.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
final energy consumption
building
air-water heat pump
PV micro-installation
Prosumer program
economic analysis
zużycie energii końcowej
budynek
pompa ciepła typu powietrze-woda
mikroinstalacja PV
program Prosument
analiza ekonomiczna
Opis:
For an exemplary single-family residential building, final energy consumption for heating and domestic hot water preparation was calculated using an air / water heat pump, consumption of electricity for household purposes (lighting, household appliances, RTV, etc.) was also calculated as based on statistical summaries. On this basis, power was selected and the annual production volume was determined by a photovoltaic micro-installation working in the ON-GIRD system pursuant to prosumer regulations contained in the Act on Renewable Energy. Then, an economic analysis was carried out basing on such static and dynamic methods as SPBT, PBP, NPV, IRR and CCE. The calculations were made for two variants, i.e.: the investment costs of the system are borne entirely by the investor, or the installation is purchased within the "EKOkredyt Prosument II" NFEP&WM program. As a result of the calculations, it was found that the investment in PV microinstallation will be profitable only if the support instruments offered by the NFEP&WM program are used. If the investor uses co-financing, the investment will pay back within 16 years at the latest and if he wants to invest his own funds, the waiting period for the return on investments can be extended to up to 21 years, which, given the twenty-five year period of operation, can turn out to be the risk that the funds invested can never be returned.
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zużycie energii końcowej do ogrzewania i przygotowania ciepłej wody użytkowej za pomocą pompy ciepła typu powietrze/woda. Określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.) Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów dotyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną w oparciu o metody statyczne i dynamiczne takie jak: SPBT, PBP, NPV, IRR oraz CCE. Obliczenia wykonano dla dwóch wariantów, tj.: koszty inwestycyjne systemu ponoszone są w całości przez inwestora lub instalacja jest zakupiona w ramach programu NFOŚiGW „EKOkredyt Prosument II”. W wyniku przeprowadzonych obliczeń stwierdzono, że inwestycja w mikroinstalację PV będzie opłacalna jedynie w przypadku skorzystania z instrumentów wsparcia oferowanych przez program NFOŚiGW. Jeżeli inwestor skorzysta z dofinansowania to inwestycja zwróci się najpóźniej w ciągu 16 lat, natomiast jeżeli będzie chciał zainwestować środki własne okres oczekiwania na zwrot nakładów może wydłużyć się nawet do 21 lat, co przy zakładanym dwudziestopięcioletnim okresie eksploatacji może okazać się, że inwestycja ta będzie niosła za sobą ryzyko, iż zainwestowane środki mogą się nie zwrócić.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2018, 63, 4; 197-202
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyniki badań eksploatacyjnych i ocena opłacalności ekonomicznej instalacji solarnej w gospodarstwie domowym
Results of operational tests and evaluation of the economical profitability of the solar installation in the household
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/884228.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
instalacje sloneczne
wykorzystanie
eksploatacja
analiza ekonomiczna
gospodarstwa domowe
podgrzewanie wody
woda ciepla
woda uzytkowa
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2015, 5
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt urządzenia ogrzewania wody z wtórnym wykorzystaniem energii z systemów chłodzenia
Design of a water heating tank based on utilization of the waste heat energy of refrigerants
Autorzy:
Sleger, V.
Sedlacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/61234.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
cieplo niskotemperaturowe
zrodla ciepla
chlodziwa
wykorzystanie
woda uzytkowa
ogrzewanie
wymienniki ciepla
roznice temperatur
Opis:
W artykule przedstawiono propozycję konstrukcji naczynia do ogrzewania wody do celów socjalnych. Jako czynnik grzewczy w zaprojektowanym systemie wykorzystano ciepło z obiegu wtórnego urządzeń chłodniczych. Uzyskane wyniki na urządzeniu prototypowym (rys. 4) pozwalają stwierdzić, że istnieje możliwość warstwowego ogrzewania cieczy wewnątrz naczynia. Dzieje się to wówczas, jeśli do miejsca wymiany ciepła dostarczana jest stale chłodna woda. Zaprojektowana konstrukcja umożliwia wykorzystanie niskotemperaturowych źródeł ciepła z obiegów chłodzących do ogrzewania wody, eliminując niebezpieczeństwo przeniknięcia mediów.
In the contribution is submitted proposal of the vessel construction for water for industrial use. For heating is being used the secondary heat from the cooling system. More frequent utilization of this energy is limited of present by two facts: 1. The cooling devices contain toxic charge and therefore the pipeline for cooling medium passing through must not be in direct contact with the heated water for hygiene and safety reasons. 2. Sufficient thermal difference for effective heat sharing is possible only when the cool water is supplied to the place of heating. The suggested construction solves both these problems. The primary pipeline with ammonia is located on the container outer side into other heat-carrying protective medium. The inner arrangement provides the isothermal water stratification in container. In to the container is located the insert from non-conductive material with outer dimension smaller than the inner diameter of container. This enables formation of the slot filled by the heated water. Between the hot water in the slot and cold water inside the vessel creates the pressure difference, heated water rises into the upper part of the container and cold water is sucked into the slot from the bottom. Within the heating almost whole container volume is therefore reached steady thermal gradient between the heating and heated medium and maximum effectiveness of the heat sharing. After verification of the suggested construction the device prototype is manufactured enabling monitoring of the temperature course in various parts of the device in dependence on time. The temperature layout inside the container was monitored by five thermal sensors located in the vessel centre line in distance of 150 mm (Fig. 3). From the measuring results is evident the heated water stratification inside the vessel. To the heating point is continuously supplied water of initial temperature (Fig. 4) for 15 minutes. Nevertheless, from the measured temperature resulted that the cooling medium secondary heat is not utilized sufficiently. The maximum output of the device at the heating beginning is almost 5 kW. This it will be necessary to extend the heat-exchanging surface of the exchanger or to adapt the slot shape along the vessel periphery to reach lower flow rate of the heated water. The described device will enable after the suggested adaptation the effective utilization of the secondary heat of the cooling medium without risk of its penetration into the heated water.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2005, 3
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of effectiveness of storing waste heat in the water accumulator
Analiza efektywności magazynowania ciepła odpadowego w akumulatorze wodnym
Autorzy:
Rutkowski, K.
Vogelgesang, J.
Findura, P.
Powiązania:
https://bibliotekanauki.pl/articles/93434.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
facilities under cover
air-water heat exchange
ballotage
diffuser
obiekt pod osłonami
wymiana ciepła powietrze-woda
balotaż
dyfuzor
Opis:
The paper presents analysis of the ways in which waste heat collected from the upper space of the plastic tunnel may be used. Warm air sucked from the upper space was pumped to a diffuser located in the process water tank. The assumed method was theoretically analysed and then tests were carried out in a real facility. Air bubbles moving in the liquid layer transferred heat, which they contained. The initial research, carried out according to the assumed method, did not bring satisfactory results. Nonetheless, some relations and possibilities of improvement of the described method by increasing the degree of complexity and the system costs were reported.
W pracy przeprowadzono analizę metody zagospodarowania ciepła odpadowego pobieranego z górnej przestrzeni tunelu foliowego. Ciepłe powietrze zasysane z górnej przestrzeni wtłaczano do dyfuzora umieszczonego w zbiorniku z wodę technologiczną. Przyjętą metodę przeanalizowano teoretycznie a następnie przeprowadzono badania w obiekcie rzeczywistym. Unoszące się pęcherzyki powietrza przemieszczając się w warstwie cieczy przekazywały zawarte w nich ciepło. Badania wstępne realizowane według przyjętej metody nie przyniosły zadawalających wyników. Niemniej zaobserwowano pewne zależności i możliwości doskonalenia opisanej metody na drodze zwiększenia stopnia złożoności i kosztów układu.
Źródło:
Agricultural Engineering; 2014, 18, 4; 205-212
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation into the thermal protection of building enclosing structures in the case of emergency heat supply
Autorzy:
Rafalskaya, Tatyana
Powiązania:
https://bibliotekanauki.pl/articles/2065650.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
ograniczona podaż ciepła
ogrzewanie
ciepła woda
akumulacja ciepła
limited heat supply
heating
hot water supply system
heat accumulation
Opis:
In case of emergency situations in heat supply systems, the water temperature in the supply line of the system decreases. It is necessary to determine the allowable operational duration of the heating system in case there is an accident, taking into account heat accumulation in exterior building envelopes and the variable flow of water in the hot water supply system. Operational modes of the heat supply system during emergency heat release from the CHP are studied. Factors affecting the thermal regime of buildings with external fences of various levels of heat accumulation are considered. A method is developed for calculating the cooling rate of the inner surface of the outer fence and the temperature on this surface at a given time. Calculated dependences are obtained for determining the permissible operating time of the heat supply system with a limited heat supply.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2021, 10, 1; 87--96
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Теплоснабжения на основе термотрансформированной энергии стабилизирующего охлаждения печи и переохлаждения теплоносителя низкопотенциальных источников
Heat supply based on thermotransformed energy of stabilizing cooling of the furnace and supercooling of coolant of low–potential sources
Autorzy:
Petrash, V.D.
Geraskina, E.A.
Danicenko, N.V.
Chernysheva, I.V.
Powiązania:
https://bibliotekanauki.pl/articles/2067774.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
heating and hot water supply
system efficiency
coolant flow rate
conversion rate
ogrzewanie
wydajność systemu
współczynnik konwersji
ciepła woda
Opis:
В статье представлены исследования совместной работы отопления и горячего водоснабжения. Установлено, что эффективность системы возрастает с увеличением расхода теплоносителя на горячее водоснабжение, а также при снижении температуры теплоносителя в системе отопления. Аналитическим способом установлено для системы с доохлаждением рациональное сочетание исходных и режимных условий, которое в системе анализируемой структуры обеспечивает оптималное значение коэффициента преобразования.
The article presents a study of the joint work of heating and hot water. It has been established that the efficiency of the system increases with an increase in the coolant flow rate for hot water supply, as well as with a decrease in the coolant temperature in the heating system. Analytically, a rational combination of initial and regime conditions is established for a system with subcooling, which in the system of the analyzed structure provides the optimal value of the conversion coefficient.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2018, 24 (174); 280-284
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality evaluation of domestic hot water supply depending on location of the apartment in apartment building
Ocena jakości ciepłej wody użytkowej w zależności od lokalizacji mieszkania w budynku mieszkalnym
Autorzy:
Perackova, J.
Krippelova, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2065386.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska
Tematy:
hot water
domestic hot water supply
temperature of domestic hot water
woda użytkowa
zaopatrzenie w ciepłą wodę użytkową
temperatura ciepłej wody użytkowej
Opis:
The paper compares temperature of domestic hot water in households with various ascending pipes located on different floors in two residential buildings of the same structural system. It describes household expenses for the consumption of hot water depending on its temperature. The article also contains subjective evaluation of domestic hot water supply’s quality depending on the location of the flat in an apartment building.
W artykule porównano temperaturę ciepłej wody użytkowej w mieszkaniach zlokalizowanych na różnych kondygnacjach w dwóch budynkach mieszkalnych wzniesionych w tym samym systemie konstrukcyjnym. W artykule opisano koszty dla indywidualnych gospodarstw domowych związane z zużyciem ciepłej wody w zależności od jej temperatury. Zawarto w nim również subiektywną ocenę jakości ciepłej wody w zależności od położenia mieszkania w budynku.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2014, 2 (14); 53--59
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of heat from sewage
Wykorzystanie ciepła z kanalizacji
Autorzy:
Perackova, J.
Podobekova, V.
Powiązania:
https://bibliotekanauki.pl/articles/2065164.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska
Tematy:
heat exchanger
heat recovery
wastewater
sewage pipes
wymiennik ciepła
rekuperacja
woda odpadowa
kanalizacja
Opis:
The increase in fossil fuel prices and the negative environmental impacts of fossil fuel use force people to use renewable energy more widely. Recovery of waste heat also ranks among the renewable energy sources. It is proposed mainly in passive houses and energy-efficient buildings. Heat from wastewater can be optimally used for heating, cooling and hot water preparation in low-energy houses. Thermal energy can be extracted from the drain outside the housing and also in the building. For heating or cooling systems in buildings sources of wastewater with higher flow, for example the administrative buildings, the swimming pools or industrial production are suitable. For preheating domestic hot water locally regenerative systems inside buildings can be used.
Wzrost cen paliw kopalnych oraz negatywne oddziaływanie na środowisko związane z ich użytkowaniem skłania ludzi do szerszego stosowania źródeł odnawialnych. Odzysk ciepła odpadowego również zalicza się do odnawialnych źródeł energii. Rozwiązania takie proponuje się głównie w domach energooszczędnych i pasywnych. Ciepło odzyskane ze ścieków może być wykorzystywane do ogrzewania, przygotowania ciepłej wody czy chłodzenia. Ciepło ze ścieków można odzyskać w budynkach, ale też poza nimi. Do ogrzewania lub chłodzenia w budynkach bardziej odpowiednie są źródła ścieków o wyższym przepływie, np. z budynków administracyjnych, basenów czy przemysłowych. Do przygotowania ciepłej wody użytkowej mogą być użyte lokalne systemy odzysku wewnątrz budynków.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2013, 2 (12); 79--86
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental set - up to research inductive heating of domestic hot water
Autorzy:
Peplińska-Matysiak, K.
Pecolt, S.
Krzyżyński, T.
Powiązania:
https://bibliotekanauki.pl/articles/118538.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
inductive
domestic hot water
heating systems
temperature sensors
badania indukcyjne
ciepła woda użytkowa
systemy grzewcze
czujniki temperatury
Opis:
The article discusses experimental set – up to research inductive heating of domestic hot water. The article presents parts which contain test stand include: water tank, measuring, heating and acquisition systems. Each part is described with important parameters. The paper further presents result of research in two setups – with the stirring of water by pump and without the stirring of water.
Artykuł przedstawia stanowisko pomiarowe do badania indukcyjnego podgrzewacza wody użytkowej o pojemności 50 litrów. Szczegółowo opisano elementy stanowiska pomiarowego do automatycznej akwizycji danych wraz z aplikacją zbudowaną w LabView. Omówiono parametry zastosowanych czujników i przetworników. W drugiej części artykułu przedstawiono wyniki badań zebrane na stanowisku badawczym podczas dwóch procesów – z mieszaniem wody w zbiorniku w obiegu zamkniętym i bez mieszania wody, dzięki czemu można było zaobserwować uwarstwienie temperaturowe wody w bojlerze.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2016, 9; 67-76
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opłacalność ekonomiczna zmiany wielkości powierzchni kolektorów słonecznych płaskich w instalacji c.w.u. budynku jednorodzinnego – studium przypadku
The economic profitability of the changing size of solar collectors surface in the case study of the household domestic hot water installation
Autorzy:
Olczak, P.
Kryzia, D.
Augustyn, A.
Olek, M.
Powiązania:
https://bibliotekanauki.pl/articles/394291.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
ciepła woda użytkowa (c.w.u.)
kolektory słoneczne
promieniowanie słoneczne
opłacalność ekonomiczna
NPV
Monte Carlo
domestic hot water (DHW)
solar collectors
solar radiation
economic profitability
Opis:
Kolektory słoneczne są głównymi elementami solarnych systemów grzewczych. Praca tych urządzeń polega na konwersji energii promieniowania słonecznego na ciepło czynnika roboczego. Czynnikiem tym może być zarówno ciecz (glikol lub woda), jak i gaz (powietrze). Ze względu na konstrukcję wyróżnia się kolektory płaskie, próżniowe, próżniowo-rurowe i skupiające. Kolektory płaskie są stosowane przede wszystkim w budynkach, w których potrzeby cieplne są niskie lub średnie, czyli na przykład w gospodarstwach domowych. Rozwój kolektorów został ukierunkowany na zwiększenia wydajności oraz poprawy efektywności ekonomicznej inwestycji. W artykule oceniono wpływ zmiany powierzchni płaskich kolektorów słonecznych na opłacalność ekonomiczną inwestycji. Do analizy wytypowano dom jednorodzinny, zlokalizowany w województwie małopolskim, w którym instalacja przygotowania ciepłej wody użytkowej została rozbudowana o system solarny. System ten składa się z płaskich kolektorów, o łącznej powierzchni absorberów 5,61 m2. Jako czynnik roboczy w instalacji stosowany jest glikol. W celu poprawy efektu ekonomicznego zaproponowano zwiększenie powierzchni absorberów. Na podstawie trzyletnich pomiarów nasłonecznienia oraz efektów cieplnych instalacji, stworzono model ekonomiczny służący do oceny opłacalności zwiększenia powierzchni kolektorów słonecznych. Obliczenia z użyciem modelu promieniowania HDKR wykonano w środowisku Matlab dla lokalizacji Tarnów (najbliższej instalacji). Ponadto na podstawie rzeczywistych pomiarów z tej instalacji, odzwierciedlających wpływ wielu niemierzalnych czynników na efektywność przetwarzania energii słonecznej, wykonano symulacje efektu ekonomicznego dla różnych wielkości zapotrzebowania na ciepło. Otrzymane wyniki uogólniono, co daje możliwość ich wykorzystania w procesie doboru wielkości powierzchni kolektorów w przypadku podobnych instalacji.
Solar collectors are the main components of the solar heating systems. This devices convert radiation from the sun into the heat of distribution medium. The medium can be either (water, glycol) or gas (air). Two types of solar panels can be distinguished on the basis of the construction criterion: flat plate collectors and evacuated tube collectors. Solar collectors development progresses towards improving their efficiency and economic profitability. Flat plate collectors are popular for low and medium heating applications, i.e. in households. In this paper, flat plate collectors with glycol as a distribution medium are investigated. The authors evaluate the impact of changing the size of the solar collectors on the heating economic profitability. A detached house, located in the Malopolskie Province was selected for the analysis. The house was fitted with domestic hot water installation which was extended with the solar system. At present, the collector area amounts to 5.61 m2. In order to improve the economic effect, the authors propose to increase their area. The radiation from the sun, sun exposure and thermal results were collected and calculated for three years. The authors prepared an economic model on the basis of the collected data. This model was created to assess the economic effect in relation to increasing the collector area. Calculations were made with the HDKR radiation model using Matlab software. The authors chose Tarnow as location because the city is the nearest to the tested installation. In addition, the authors created a simulation that allowed the economic effect for different detached houses with different heat demands to be assessed. By using real data an impact of many non-measurable factors on the efficiency of solar energy conversion could be taken into account in the simulation. The obtained results have been generalized and thus can be applied in a similar installation during the process of choosing an appropriate collector area size.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2018, 102; 77-90
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies