Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water stability" wg kryterium: Temat


Tytuł:
Ocena mikrobiologiczna osadów wodociągowych, na przykładzie wybranego Systemu Zaopatrzenia w Wodę
The Microbiological Evaluation of Deposits Come from Water Network on the Example of Selected Water Supply System
Autorzy:
Szuster-Janiaczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818065.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady wodociągowe
biofilm
stabilność chemiczna
stabilność biologiczna wody
korozja
deposits
chemical water stability
biological water stability
corrosive properties
Opis:
The study described herein was carried out on a technical scale on a water supply system servicing approximately 350 thousand inhabitants. The total length of the water mains and distribution pipelines in the area under review approximates 1 744 km and 37 264 water supply connections. The greater part of the water supply area is compact, and a region (a maximum located to the south) is clearly separated from the rest. Because the Waterworks Company, which manages the examined SDW, does not exploit its own intakes and water treatment plants, it has to purchase the water from two external suppliers (D-1 and D-2). The studied area is supplied with water from water mains through 21 points (P1-P21) which, in many cases, are also points of water pressure reduction (reduction stations) or elevation (pumping stations). In 8 of the 21 points of purchase, through appropriate installations, phosphate corrosion inhibitors are dispensed to the water. In an article, the microbiological evaluation of deposits collected from five points in the water distribution system was conducted. The analyzed deposits were located at three different materials: cast iron, plastic, and asbestos cement, which in terms of age ranged from 3 to 40 years. Samples of deposits were collected using the same method for various months during one calendar year. Bacteriological analysis of samples included determination of: total number of mesophilic bacteria (growing at 37°C), psychrophilic (growing at 22°C), coliform, faecal coliform (thermotolerant) or E. coli, fecal streptococci, Clostridium perfingens, bacteria of the Pseudomonas genus, bacteria precipitating iron, anaerobic bacteria sulfate reducing (SRB-initiate corrosion processes), actinomycetes and fungi which are the possible contamination of the soil. Results of microbiological testing showed that the surface of the pipes developed biofilm, which is a significant reservoir of microorganisms, which is a phenomenon often occurring in water distribution systems. The analysis showed a variety of deposits in terms of microbiological, depending on the type of material which they were originally placed on. In the case of sediment samples taken from the plastic pipe, the size of the bacteria grown in the two temperatures was several times higher than in the case of samples taken from the cast iron pipe. In the case of the water sample taken from the plastic, the size of bacteria grown at both temperatures exceeded the limit values for water several times.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 815-827
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność odmanganiania wód o wysokiej twardości
Influence of High Water Hardness on the Efficiency of Manganese Removal
Autorzy:
Błażejewski, M.
Kosmala, A.
Powiązania:
https://bibliotekanauki.pl/articles/236630.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
odmanganianie
twardość węglanowa
stabilność wody
manganese removal
carbohydrate hardness
water stability
Opis:
W pracy omówiono wyniki badań w skali laboratoryjnej i technicznej w zakresie wpływu twardości wody na skuteczność jej odmanganiania na złożach utleniających. W skali modelowej określono wpływ twardości ogólnej w zakresie 300÷960 gCaCO3/m3 na usuwanie manganu w zakresie stężeń 1,7÷3,7 gMn/m3 przy prędkości filtracji około 5 m/h. Stwierdzono, że w badanym zakresie twardość ogólna, przy względnie niskiej zasadowości i pH=7,8 nie miała wpływu na efektywność usuwania manganu z wody. W badaniach w skali technicznej stwierdzono, że w wyniku napowietrzania wody o wysokiej twardości zmieniała się jej równowaga węglanowo-wapniowa, czego efektem było wytrącanie w złożu węglanu wapnia, blokujące powierzchnię złoża utleniającego, co powodowało całkowity zanik efektu odmanganiania wody. Wyeliminowanie tego zjawiska uzyskano w dwustopniowym układzie filtracji wody, w którym odżelazianie (poprzedzone napowietrzaniem) zachodziło w filtrach pierwszego stopnia, a mangan był skutecznie usuwany w złożu utleniającym.
Laboratory and full-scale investigations were carried out using a physical model of a rapid filter and an activated filter bed, respectively. The influence of water hardness (300 to 960 gCaCO3/m3) and alkalinity (190 to 230 gCaCO3/m3) on the efficiency of manganese removal, at a manganese concentration ranging between 1.7 and 3.7 gMn/m3, was examined at the laboratory conditions. Full-scale experiments were performed at the Water Treatment Plant of Pępowo, with groundwater samples of a high iron and manganese content, a total hardness of 650 gCaCO3/m3, a maximum alkalinity of 420 gCaCO3/m3, and pH varying from 6.8 to 7.0. Laboratory investigations revealed that, in the tested range of manganese concentration, total hardness did not affect the efficiency of manganese removal at pH 7.8. Under full-scale conditions, involving two-stage filtration via oxidation filter beds, the carbohydrate-calcium equilibrium was disturbed due to the aeration of the high-hardness water under treatment. Calcium carbonate precipitated in the bed, thus clogging the surface of the oxidation filter bed. In the first year of operation, the removal of both manganese and iron was effective. Later, the manganese removal effect decreased continually and disappeared, and iron was detected in the treated water. To eliminate these adverse effect, a two-stage water filtration system was installed, where iron removal (following aeration) is achieved with a sand filter bed (first stage), and manganese is efficiently removed with the oxidation filter bed (second stage).
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 39-41
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasiedlanie granulowanych węgli aktywnych przez mikroorganizmy w procesie uzdatniania wody
Water treatment involving granular active carbon filters: Problem of bacterial colonization
Autorzy:
Kiedryńska, L.
Powiązania:
https://bibliotekanauki.pl/articles/236460.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
uzdatnianie wody
granulowany węgiel aktywny
stabilność wody
water treatment
granular active carbon
water stability
Opis:
W pracy dokonano analizy przebiegu i efektywności zasiedlania złoża modelowego filtru sorpcyjnego wypełnionego granulowanym węglem aktywnym przez mikroorganizmy. Określono liczebności bakterii w wodzie dopływającej i odpływającej ze złoża węglowego, na tle skuteczności oczyszczania wody, oraz znajdujących się w błonie biologicznej na węglu aktywnym. Wykazano, że usuwaniu związków organicznych około 0,95 gC/m3 (jako OWO) towarzyszyło usunięcie 8 mgC/m3 jako biocenoza bakterii, co stanowiło 0,8% usuniętego węgla organicznego. Zaproponowano, aby ze względu na wypłukiwanie pyłu węgla i bakterii z filtru stosować filtr piaskowy po procesie sorpcji lub filtr dwuwarstwowy, węglowo-piaskowy, zamiast złoża węglowego.
The aim of the study was to analyze the efficiency of bacterial colonization of the granular activated carbon (GAC) filter. According to the efficiency of water treatment, the following parameters were determined: bacterial growth on the GAC, and the number of bacteria in the influent and effluent water. The study was carried out at the R&D Water Treatment Plant, Warsaw University of Agriculture. Taking into account the penetration of organic carbon, as well as bacteria and carbon dust from the GAC, into the water supply system, the application of a sandwich filter (GAC-sand) or a sand filter after the GAC is recommended for an effective control of bacterial growth.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 1, 1; 39-42
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stopnia rozmywalności płatków owsianych błyskawicznych
An assessment of the degree of washability of instant oat flakes
Autorzy:
Panasiewicz, M.
Tatara, A.
Chudkowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/287652.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
płatki owsiane błyskawiczne
rozmywalność
stabilność wodna
urządzenie
instant oat flakes
washability
water stability
Opis:
W pracy przedstawiono zakres zmian stopnia rozmiękczania i rozmywalności płatków owsianych błyskawicznych testowanych w zróżnicowanych warunkach ośrodka wodnego (temperatura wody, czas rozmywania). Badania ukierunkowano pod kątem oceny zmiany, wybranych cech sensorycznych i organoleptycznych (głównie masy, struktury i konsystencji) płatków owsianych błyskawicznych oferowanych w sieci handlowej.
The paper presents a scope of changes of the degree of softening and washability of instant oat flakes tested in different water environment conditions (water temperature, wash-out time). The tests were oriented to assess changes of selected sensory and organoleptic qualities (mainly mass, structure and consistency) of instant oat flakes offered on the market.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 5 (93), 5 (93); 321-330
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory investigations of deep-water wave transformation and stability
Autorzy:
Wilde, P.
Sobierajski, E.
Chybicki, W.
Sobczak, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/240986.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
laboratory investigations
deep-water wave transformation
deep-water wave stability
Opis:
The authors performed laboratory investigations and the analysis of the transformation of deep-water waves in the flume of the Institute of Hydro-Engineering. Special wave trains were generated by our piston-type wavemaker. Due to the transformation the wave profiles changed along the path of propagation. At first, the changes appeared at the ends of the wave train. Far from the generator they intruded into the middle interval of initially regular waves. Finally, the whole wave train consisted of a set of irregular groups. To study the instability problem the wave trains were modulated by superposition of wave groups with very small amplitudes. The number of waves in a group was a very important parameter. When the number was proper, even small amplitudes of modulation resulted in strong development of amplitudes of wave groups. In our theoretical analysis the non-linear Schroedinger equation was used. The comparison of laboratory and theoretical results proved that this equation is useful but it does not describe the phenomenon in the best way. There have been many attempts to construct a numerical procedure that describes the propagation of water waves. Very often the numerical algorithm is not stable and the results of calculation diverge from the expected behaviour. The authors believe that in many cases the instability is due to the physical loss of stability of the wave train and thus it is necessary to have a good understanding of the physics of the studied motion.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2003, 50, 3; 287-313
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie programów symulujących skład jonowy wody do oceny stabilności chemicznej wody wodociągowej
Assessing the chemical stability of tap water by means of the software for ionic composition simulation
Autorzy:
Łomotowski, J.
Siwoń, Z.
Powiązania:
https://bibliotekanauki.pl/articles/236350.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
osady w sieci
skład jonowy
stabilność wody
tap water
precipitation
ionic composition
water stability
Opis:
Wymywanie osadów z sieci wodociągowej może występować na skutek zmian warunków hydraulicznych oraz składu chemicznego wody w sieci wodociągowej. Może być także efektem zmian w układzie technologicznym stacji uzdatniania wody, zmian składu wody surowej (szczególnie na ujęciach wód powierzchniowych) lub mieszania się w sieci wodociągowej wód pochodzących z różnych ujęć. Zastosowanie programów komputerowych do symulacji składu jonowego wody i obliczania indeksów stabilności w tych wypadkach może okazać się cennym narzędziem diagnostycznym. W pracy przedstawiono możliwości wykorzystania programu PHREEQC 2.3 do symulacji składu jonowego wody w praktyce wodociągowej. Stwierdzono ich użyteczność przy prognozowaniu zdolności do wytrącania minerałów z wody wodociągowej oraz sprawdzania poprawności analiz chemicznych wody. Wykazano, że na podstawie indeksów stabilności chemicznej wody można diagnozować procesy zachodzące w sieciach wodociągowych.
Mineral precipitation in the water-pipe network occurs due to the change in the hydraulic conditions or in the chemical composition of the water. But there are some other contributing factors, e.g. the change in the treatment train applied, variations in the composition of raw water (especially at surface water intakes), or the water mix produced in the pipeline by the inflow from a variety of intakes. It seemed therefore advisable to evaluate the chemical stability indexes for the pipe water with the help of the software for simulating the ionic composition of the water, as this was likely to be a useful diagnostic tool. For the purpose of the study reported on in this paper, use was made of the software PHREEQC for ionic composition simulation in water distribution engineering. The software was found to be of utility in predicting mineral precipitation from the tap water and in assessing the reliability of chemical analyses. The study has shown that with the chemical stability indexes obtained via the described method it is possible to predict the processes occurring in the water distribution networks.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 4, 4; 13-16
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu promieniowania nadfioletowego na stabilność mikrobiologiczną wody
Studies of the influence of UV irradiation on drinking water microbial stability
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Powiązania:
https://bibliotekanauki.pl/articles/237624.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
oczyszczanie wody
dezynfekcja
związki organiczne
stabilność wody
tap water
water treatment
disinfection
organic matter
water stability
Opis:
Wykorzystanie promieniowania UV do dezynfekcji wody staje się coraz powszechniejsze w polskiej praktyce oczyszczania wody przeznaczonej do spożycia przez ludzi. Dezynfekcja wody promieniami UV często jest łączona sekwencyjnie z dezynfekcją chemiczną, aby zapobiec wtórnemu rozwojowi bakterii w systemach dystrybucji wody. Znane są jednak przypadki, że woda po procesie dezynfekcji promieniami UV podawana jest wprost do sieci wodociągowej, bez dodatkowej chemicznej ochrony. Artykuł przedstawia wyniki badań nad wpływem promieniowania UV na zmiany stabilności mikrobiologicznej wody w krakowskiej sieci wodociągowej zasilanej ze stacji oczyszczania wody „Raba”. Próbki wody poddano w warunkach laboratoryjnych naświetlaniu promieniami UV za pomocą niskociśnieniowej lampy UV TNN 15/32 w reaktorze fotochemicznym LRS-3 firmy Heraeus. Zastosowano dawki promieniowania UV wynoszące 400 J/m2, 1860 J/m2 oraz 10000 J/m2. Stabilność mikrobiologiczną wody oceniano na podstawie obserwacji wzrostu bakterii heterotroficznych w czasie do 18 d. Analiza otrzymanych wyników pokazała, że promieniowanie UV może niekorzystnie wpływać na stabilność mikrobiologiczną wody w systemie dystrybucji. Wykazano, że w próbce wody naświetlanej promieniami UV dawką 400 J/m2 liczba bakterii heterotroficznych była ponad 3-krotnie większa niż w próbce wody poddanej tylko ozonowaniu. Stwierdzono, że większe dawki promieniowania UV oraz sekwencyjne stosowanie ozonowania i promieniowania UV, najprawdopodobniej ze względu na mineralizację związków organicznych, poprawiały stabilność mikrobiologiczną wody.
Application of UV radiation for water disinfection becomes more and more popular in Polish treatment plants that supply drinking water. UV disinfection is often sequentially coupled with chemical disinfection to prevent secondary growth of bacteria in water distribution systems. However, there are cases where directly after the UV disinfection water is pumped into a distribution system, without any additional chemical protection. The article presents results of the research on the influence of UV radiation on variations in water microbial stability in the distribution system supplied by Raba water treatment plant. Water samples were irradiated in laboratory conditions in the photochemical reactor (Heraeus) with the UV low-pressure lamp TNN 15/32. The UV doses of 400 J/m2, 1860 J/m2 and 10,000 J/m2 were applied. Water microbial stability was determined on the basis of heterotrophic bacteria growth rate in the period of up to 18 days. An analysis of the results demonstrated that UV radiation could adversely affect water microbial stability in distribution systems. The highest number of heterotrophic bacteria, over three-times higher compared to a purely ozonated sample, was recorded in the water sample irradiated with 400 J/m2. Higher doses of UV radiation as well as ozone/UV sequence improved water microbial stability, most likely due to organic matter mineralization.
Źródło:
Ochrona Środowiska; 2015, 37, 4; 47-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the PHREEQC program to assess the chemical stability of tap water in Kielce
Zastosowanie programu PHREEQC do oceny stabilności chemicznej wody wodociągowej w Kielcach
Autorzy:
Metryka-Telka, Monika
Kowalik, Robert
Gawdzik, Jarosław
Gawdzik, Barbara
Gawdzik, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/402211.pdf
Data publikacji:
2020
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
PHREEQC
water chemical stability
stability index
stabilność chemiczna wody
wskaźnik stabilności
Opis:
The research was conducted on samples of water in Kielce from two intakes: Białogon and Zagnańsk. The results of selected indicators for these waters were presented, among others, the most important ones influencing its chemical stability i.e. calcium or magnesium. Then, using the PHREEQC program, stability indices were calculated for water in Kielce from the two shots in question. In the next stage, the correctness of the water test method was checked by means of a program through the ionic balance of the water and comparison of pH of the water determined with the value determined by calculation. For the above mentioned activities, tables and calculations were prepared on the basis of which appropriate conclusions were made.
Badania przeprowadzono na próbkach wody w Kielcach pochodzące z dwóch ujęć: Białogon i Zagnańsk. Przedstawiono wyniki wybranych wskaźników dla tych wód, m.in. najważniejszych wpływających na ich stabilność chemiczną, tj. wapnia lub magnezu. Następnie, za pomocą programu PHREEQC, obliczono wskaźniki stabilności dla wód w Kielcach z dwóch ujęć, o których mowa. W kolejnym etapie sprawdzono poprawność metody badania wody za pomocą programu poprzez bilans jonowy wody i porównanie pH wyznaczonej wody z wartością wyznaczoną w wyniku obliczeń. Dla wyżej wymienionych czynności przygotowano tabele i obliczenia, na podstawie których wyciągnięto odpowiednie wnioski.
Źródło:
Structure and Environment; 2020, 12, 1; 41-45
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relations between soil structure, number of selected groups of soil microorganisms, organic matter content and cultivation system
Autorzy:
Dabek-Szreniawska, M.
Wyczolkowski, A.
Jozefaciuk, B.
Ksiezopolska, A.
Szymona, J.
Stawinski, J.
Powiązania:
https://bibliotekanauki.pl/articles/24174.pdf
Data publikacji:
1996
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
organic matter content
mercury
water stability
soil structure
microorganism
soil aggregate
cultivation system
brown earth
Źródło:
International Agrophysics; 1996, 10, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie procesu dezynfekcji w zapewnieniu bezpieczeństwa mikrobiologicznego wody przeznaczonej do spożycia przez ludzi
Role of disinfection process in ensuring microbiological safety of drinking water
Autorzy:
Dymaczewski, Zbysław
Jeż-Walkowiak, Joanna
Michałkiewicz, Michał
Sozański, Marek
Powiązania:
https://bibliotekanauki.pl/articles/237203.pdf
Data publikacji:
2019
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
disinfection
disinfection by-products
biological water stability
monitoring
uzdatnianie wody
dezynfekcja
produkty uboczne dezynfekcji
biologiczna stabilność wody
Opis:
Przedstawiono genezę powstania i tradycję stosowania procesu dezynfekcji w systemach uzdatniania wody. Zwrócono uwagę na złożoność i trudności metodyczne dezynfekcji, zaznaczając, że jest ona jednocześnie podstawowym celem technologii uzdatniania wody, zapewniającym jej bezpieczną jakość mikrobiologiczną. Zaprezentowano nowe podejście do procesu dezynfekcji, wynikające z rozszerzenia funkcji i celów tego procesu, jako podstawy bezpieczeństwa jakości wody przeznaczonej do spożycia. Wykazano, że dezynfekcja powinna być integralnym elementem całego systemu zaopatrzenia w wodę, obejmującego zarówno technologię uzdatniania, jak i układ dystrybucji wody. Podejście takie wynika z miejsca dezynfekcji w systemie, jako ogniwa pośredniego między układem technologicznym a siecią wodociągową. Koncepcja ta zakłada wykorzystanie dezynfekcji również jako procesu monitorującego i diagnozującego bezpieczeństwo całego systemu uzdatniania i dystrybucji wody. Zwrócono też uwagę na zadania badawcze towarzyszące projektowaniu i eksploatacji procesu dezynfekcji, w połączeniu z wiarygodną oceną biologicznej stabilności wody w sieci wodociągowej. Przeanalizowano kryteria metodyczne procesu dezynfekcji, wpływające na wybór chemicznych utleniaczy, ich dawek, czasu kontaktu, miejsc dawkowania, a także identyfikację i ograniczanie powstawania produktów ubocznych.
The paper discusses the origins and tradition of disinfection process application in water treatment systems paying special attention to its complexity and methodological problems. Disinfection was presented as the main objective of water treatment technology that guarantees safe microbiological water quality. A new approach to the process of disinfection was proposed as a result of the expansion of its functions and objectives as a foundation for drinking water quality safety. It was demonstrated that disinfection should become an integral part of the whole water supply system, comprising both water treatment technology and distribution system. Such an approach results from the position of disinfection process in the system, as an indirect link between the technological system and distribution network. The concept also assumes use of disinfection to monitor and diagnose safety of the water supply system as a whole. Attention was also paid to the research tasks accompanying design and operation of the disinfection process in combination with a reliable evaluation of biological water stability in water networks. The article presents the analysis of methodological criteria of the disinfection process affecting chemical oxidant and dose selection, contact time, dosing site location as well as by-product identifi cation and reduction in their formation.
Źródło:
Ochrona Środowiska; 2019, 41, 1; 3-9
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological Stability of Water after the Biofiltration Process
Autorzy:
Zamorska, J.
Powiązania:
https://bibliotekanauki.pl/articles/124588.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
biofiltration
microbiology of water
biological stability of water
flow cytometry
Opis:
One of the most frequently implemented processes in the water treatment technology is filtration through a biosorption bed. The techniques based on biochemical processes involving bacteria result in obtaining high quality of water. There are a number of different materials used as the filler material for biological filters. Carbon deposits are the most popular, due to their high effectiveness. The problem with the use of this process is the leaching of microorganisms from the biofilm and the biological stability of water thus obtained. There is a need to develop quick methods to assess the microbiological quality of this water. Modern techniques for determining the amount of microorganisms, such as flow cytometry and luminometry may be the right tools. The water collected for testing came from the Water Treatment Station located in the Podkarpackie voivodeship. The microbiological tests carried out in the analyzed water samples collected after the filtration process on granular activated carbon. Both traditional culture method and modern techniques used to determine the number of microorganisms (flow cytometry, luminometric ATP assay) demonstrated an increase in the number of microorganisms in the examined waters (in the water after the filtration process and in the water introduced into the water supply network) after the incubation process for 3 and 7 days at 15 and 22°C.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 234-239
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of process conditions on quality and energy consumpion during extrusion-cooking of carp feed
Wplyw warunkow procesu na jakosc i energochlonnosc ekstrudowanej karmy dla karpia
Autorzy:
Oniszczuk, T.
Moscicki, L.
Wojtowicz, A.
Mitrus, M.
Rejak, A.
Zawislak, K.
Sobczak, P.
Mazur, J.
Oniszczuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/793431.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
extrusion-cooking
specific mechanical energy
water stability
single screw extrusion-cooker
carp
feed
freshwater fish
standard mixture
raw material
moisture content
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aggregate water stability of sandy and clayey loam soils differently compacted with and without wheat plants
Autorzy:
Balashov, E.
Bazzoffi, P.
Powiązania:
https://bibliotekanauki.pl/articles/26026.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
wheat plant
water stability
growth parameter
root hair
texture
winter wheat
root
plant root
sandy soil
clay soil
soil
aggregation
compaction
loamy soil
Źródło:
International Agrophysics; 2003, 17, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rheological Properties and Water-in-Oil Structural Stability of Emulsion Matrixes
Autorzy:
Wang, L.
Fang, J.
Powiązania:
https://bibliotekanauki.pl/articles/357954.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
emulsifier
emulsion matrix
rheological properties
viscoelasticity
water-in-oil structural stability
Opis:
The emulsion explosive is one of the important industrial explosives.The structural stability of the water-in-oil (W/O) emulsion matrix of an emulsion ex plosive determines the reliability of its initiation, safety and detonation performance. It is known that the emulsifier is one of the most important factors affecting W/O structural stability. In this paper, several emulsifiers with the functionalities of imide, amide, ester, salt, and sorbin monooleate (SMO) were selected. From the perspective of the rheological properties, the effects of the emulsifier structure and its functionality on the viscosity and visco-elastic properties of the emulsion matrix were analyzed and researched. The results show that emulsifiers with imide/amide functionality and their corresponding emulsion matrixes have higher viscosity at normal temperatures and better fluidity at high temperatures than those of the others. The linear visco-elastic region (LVR) for emulsion matrixes containing these emulsifiers is wider than that of the others. The effect of a change in ambient temperature on the viscosity for a complex emulsifier is small. The emulsion matrix containing the emulsifier named LZ2727B is the most stable, followed by the emulsifier named LZ2727D. This conclusion is consistent with the conclusions from tension tests and from high and low temperature cycling experiments. From the emulsifiers studied in this paper, LZ2727B and LZ2727D emulsifiers are very suitable for manufacturing packaged emulsion explosives. On the other hand emulsifiers based on SMO functionalities, named LZ2731 and LZ2735, are the best choices for manufacturing bulk emulsion explosives.
Źródło:
Central European Journal of Energetic Materials; 2013, 10, 1; 87-102
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu napowietrzania do desorpcji dwutlenku węgla z wody powierzchniowej na przykładzie wodociągu w Dębicy
The use of the aeration process for the desorption of carbon dioxide from surface water: A case study
Autorzy:
Zymon, W.
Powiązania:
https://bibliotekanauki.pl/articles/237816.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dwutlenek węgla
napowietrzanie
desorpcja
stabilność chemiczna wody
carbon dioxide
aeration
desorption
chemical stability of water
Opis:
Na przykładzie wodociągu w Dębicy omówiono problem stabilizacji składu chemicznego wody o charakterze agresywnym, spowodowanym stosowaniem dużych dawek koagulantu podczas oczyszczania wody powierzchniowej. Przeprowadzono analizę skuteczności usuwania agresywnego dwutlenku węgla przy użyciu metody chemicznej (dawkowanie węglanu sodu) i fizycznej (napowietrzanie). Biorąc pod uwagę skuteczność obu procesów oraz warunki eksploatacyjne w stacji oczyszczania wody, wybrano metodę desorpcji dwutlenku węgla przy użyciu powietrza w kolumnowym desorberze z pierścieniami Białeckiego. Zakładając wymaganą jakość wody oczyszczonej, określono podstawowe parametry projektowe kolumny desorpcyjnej do usuwania dwutlenku węgla. Przestawiono także sposób adaptacji nieczynnej kolumny filtracyjnej na desorber kolumnowy. Analiza ponadrocznej eksploatacji urządzenia do usuwania dwutlenku węgla z wody w wodociągu w Dębicy potwierdziła skuteczność przyjętego rozwiązania.
With the Waterworks of Debica as a case in point, the paper addresses the problem of stabilizing the chemical composition of the water whose aggressive character is attributable to the high coagulant doses applied in the course of the treatment process. Two methods for the removal of aggressive carbon dioxide, a chemical one (dosage of sodium carbonate) and a physical one (aeration), were made subject to analysis in view of their efficiencies. Taking into account the efficiencies of the two processes and the operating conditions at the water treatment station, the method of carbon dioxide desorption (with air in a column desorber packed with Bialecki rings) was chosen. Upon setting the desired quality of the treated water, the basic design parameters of the desorption column for carbon dioxide removal were determined. It was also shown how to adapt an idle filter column in order to make it act as a desorber. The analysis of a one-year operation of the unit for carbon dioxide removal from water at the Waterworks of Debica has substantiated the efficiency of the design adopted.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 4, 4; 65-68
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A methodology of identification of the aircraft translational dynamic stability derivatives in water tunnel experiments
Autorzy:
Lichoń, D.
Powiązania:
https://bibliotekanauki.pl/articles/243656.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
aircraft dynamic stability
dynamic stability derivatives
water tunnel
Opis:
The aircraft dynamic stability derivatives (DSD) describe the variation of aerodynamics forces and moments with respect to disturbances of kinematic parameters (translational or rotational). The knowledge of DSD is important due to determination of aircraft dynamic stability characteristics. Thus, the identification of DSD is an issue of analytical or numerical analysis and experimental researches. Experimental methods use air or water tunnel tests. The investigated model is submitted to forced oscillations with relatively low amplitude, which simulates the disturbances around steady state flight parameters. The variation of forces and moments are measured by strain balance system, which allows identifying DSD. This work is focused on development the methodology of experimental identification the aircraft translational DSD in water tunnel tests. Study of available publications shows that model manipulator system usually provides rotational movements around three axes. Therefore, the measurements can be performed with respect to rotational velocity disturbances. However, by addition the translational manipulator with one degree of freedom the measurements can be expanded into translational velocity disturbances (normal and sideslip). It is necessary to point that axial velocity disturbance is omitted due to lack of axial force component in strain balance construction. The proposed modification does not affect the construction of rotational manipulator or balance. The article contains translational manipulator scheme, modification of data acquisition system and mathematical process of identification the aircraft translational dynamic stability derivatives.
Źródło:
Journal of KONES; 2016, 23, 4; 291-296
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of chemical stability of tap water in terms of required level of technological safety
Analiza stabilności chemicznej wody wodociągowej pod kątem wymaganego poziomu bezpieczeństwa technologicznego
Autorzy:
Pietrucha-Urbanik, K.
Tchórzewska-Cieślak, B.
Papciak, D.
Skrzypczak, I.
Powiązania:
https://bibliotekanauki.pl/articles/205102.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chemical stability of water
corrosion indice
technological safety
risk criteria
stabilność chemiczna wody
wskaźnik korozji
bezpieczeństwo technologiczne
kryteria ryzyka
Opis:
The main goal of this work is to show the new approach to determining safety technological levels (SLs) in terms of water quality and its chemical stability, as well as issues of water corrosion properties in water distribution systems (WDSs), due to the fact that water supply pipes are prone to corrosion. In the paper the methodology of determining the risk associated with threat to technical infrastructure was considered. The concept was studied on the basis of real operational data from the water treatment plant. The probability of exceeding the individual parameters for WTPI is slightly larger than for WTPII, which means that this water treatment process may cause lack of chemical stability in the water supply network. Operators should anticipate in the process of designing water distribution system, using proper materials, as to ensure an adequate level of safety from the water source to the water recipient. It should be noted that it is necessary to adjust the material of internal installation of water supply networks to the parameters of the water. At present, there are no correlations between the designing step and water parameters. It was concluded that to protect the water supply infrastructure, which belongs to critical infrastructure, water company should put more emphasis on distribution of stable water that has not potentially corrosion properties. Some suggestions were made for the protection of WDS and to ensure safety of system functioning and long-term usability of water pipes.
Głównym celem pracy jest przedstawienie nowego podejścia do określania poziomów technologicznych bezpieczeństwa (SL) w zakresie jakości wody i jej stabilności chemicznej, a także właściwości korozyjnych wody w systemach dystrybucji wody (WDS), ze względu na fakt, iż przewody wodociągowe są podatne na korozję. W pracy przedstawiono metodologię określania ryzyka związanego z wystąpieniem zagrożeń dla infrastruktury technicznej. Analiza została wykonana na podstawie uzyskanych danych eksploatacyjnych ze stacji uzdatniania wody. Prawdopodobieństwo przekroczeń poszczególnych parametrów w przypadku WTPI jest nieznacznie większe od WTPII, co oznacza iż ten proces uzdatniania wody może powodować brak zachowania stabilności chemicznej w sieci wodociągowej. Operatorzy powinni przewidzieć w procesie projektowania systemu dystrybucji wody, użycie odpowiednich materiałów, tak aby zapewnić odpowiedni poziom bezpieczeństwa od źródła wody do odbiorcy. Należy zauważyć, że niezbędne jest dostosowanie materiału wewnętrznej instalacji sieci wodociągowej do parametrów wody nie odwrotnie. W chwili obecnej nie ma korelacji pomiędzy etapem projektowania, a parametrami wody. W celu ochrony infrastruktury wodociągowej, które należą do infrastruktury krytycznej, przedsiębiorstwo wodociągowe powinna położyć większy nacisk na dystrybucję stabilnej wody, która nie ma właściwości korozyjnych. W pracy zaproponowano podjęcie działań zapewniających ochronę systemu dystrybucji wody przed utratą stabilności chemicznej wody.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 3-12
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of geotechnical conditions on damage states of Gdansk Bay Coast cliff formations
Autorzy:
Mieloszyk, E.
Wyroślak, M.
Powiązania:
https://bibliotekanauki.pl/articles/258882.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
coastal cliff
escarpment stability
underground water flow
Opis:
A geotechnical aspect of destruction processes of seashores was identified based on the case of erosion of Gdansk Bay Coast cliff formations. Causative factors of landslide were described in the context of natural phenomena, land development and its anthropogenic transformations. Possible directions of theoretical analysis of changes in groundwater relations were indicated.
Źródło:
Polish Maritime Research; 2018, 3; 137-142
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity-based stability evaluation of closed piping networks
Autorzy:
Fu, Y.
Cai, Y.
Wu, K.
Powiązania:
https://bibliotekanauki.pl/articles/1933181.pdf
Data publikacji:
2007
Wydawca:
Politechnika Gdańska
Tematy:
closed-loop water system
sensitivity
stability
evaluation
Opis:
Aiming at a closed-loop water system of HVAC engineering, the authors put forward an evaluation method of systems' stability based on sensitivity. It has three evaluating indexes: [alfa] - the summation of flow changes in other subcircuits influenced by resistance change in a certain subcircuit [Beta] - the summation of flow changes in a certain sub circuit influenced by resistance changes in other subcircuits; [gamma] - average [Beta] (or [alfa]) value of each subcircuit, reflecting the strength of regulating interference between subcircuits. The method is used to analyze the stability of a reverse return system (RRS) and a direct return system (DRS). The DRS subcircuit farthest from the heat source and the middle RRS are the least stable. Stability of the whole RRS is inferior to that of the DRS.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2007, 11, 3; 197-202
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Analysis of the Stability of the Communication Support Stabilized by Gabion Wall with Variable Configuration
Autorzy:
Zamiar, Zenon
Surowiecki, Andrzej
Saska, Piotr
Balawejder, Adam
Powiązania:
https://bibliotekanauki.pl/articles/504194.pdf
Data publikacji:
2019
Wydawca:
Międzynarodowa Wyższa Szkoła Logistyki i Transportu
Tematy:
communication embankment
gabion wall
water damming
stability
Opis:
The subject of the article concerns the stabilization of communication earthworks using the so-called lightweight retaining structures. The stability of the embankment with the embankment built with the gabion wall is analysed, assuming a uniformly distributed load on the crown and a case of unilateral water pressure in the event of a flood. Final results of stability calculations made with the Fellenius and Bishop method in the form of slip surface with the smallest value of the coefficient were presented. Then, assuming the case of damming up of flood water, discretization of the filtration area, velocity distribution and hydrodynamic grating and slip surfaces were developed. The variable parameter is the wall configuration.
Źródło:
Logistics and Transport; 2019, 42, 2; 109-116
1734-2015
Pojawia się w:
Logistics and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stability of air nucleus in liquid water and cavitation inception on marine engineering
Autorzy:
Fu, Q.
Chen, M.
Wang, X.
Zhu, R.
Zhang, G.
Powiązania:
https://bibliotekanauki.pl/articles/260137.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
air nuclei
water
molecular dynamics
stability
surface tension
Opis:
The micro air nucleus widely distributed in the ocean is a necessary condition for the cavitation of hydraulic machinery in seawater. In order to study the stability of air nucleus in seawater and cavitation inception, the computational domain of water molecules with air nucleus was studied using the method of molecular dynamics simulation, and the transient characteristics of air nucleus in liquid water were obtained. The key factors influencing nuclei stability were analyzed. The results showed that air nucleus with a certain mass could maintain the dynamic equilibrium in liquid water. The internal density of air nuclei had a critical value that allowed the nuclei to stably exist in water. The air nuclei mass was the decisive factor in its equilibrium volume in water, and the two were positively correlated. The internal density of air nuclei was negatively correlated with the nuclei radius when the nuclei was stable in water. Liquid surface tension was an important factor affecting the stability of the air nuclei. The larger the initial radius of nuclei, the smaller the water pressure, and the more likely the cavitation occurs.
Źródło:
Polish Maritime Research; 2018, S 3; 111-119
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pływalności i stateczności pojazdu ratownictwa wodnego do prowadzenia akcji na akwenach śródlądowych i wodach przybrzeżnych oraz pokrytych lodem
An analysis of floatability and stability of an inland water rescue vehicle for conducting the rescue activities on the inland waters covered by ice
Autorzy:
Cwojdziński, L.
Gerigk, M. K.
Szulczewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/251719.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
pływalność
stateczność
ratownictwo wodne
buoyancy
stability
water rescue
Opis:
W artykule przedstawiono wyzwania związane z zastosowaniem małego pojazdu ratownictwa wodnego do prowadzenia akcji na akwenach śródlądowych i wodach przybrzeżnych oraz pokrytych lodem. Przedstawiono koncepcję małego pojazdu ratownictwa wodnego. Opisano wybrane elementy modelowania pływalności i stateczności pojazdu. Przedstawiono podstawowe elementy związane z modelowaniem ruchu i oceną zachowania się obiektu w warunkach operacyjnych. Podano wnioski końcowe dotyczące prowadzonych badań.
In the paper the basic problems associated with development the concept of an inland water rescue vehicle PRWL which is devoted to perform the rescue activities on the inland waters covered by ice is presented. The research objective, PRWL vehicle, research method and some elements of the research directed towards development of the PRWL vehicle technology demonstrator has been described. Some elements asso-ciated with assessment of the vehicle floatability, stability and performance in the water have been presented. Some information on a possible application of the PRWL vehicle have been given. The information presented in the paper are the results of work of the authors and results of research investigations conducted at the Gdańsk University of Technology, Faculty of Ocean Engineering and Ship Technology between 2014 and 2015.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 331-335, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water quality effects on a sulfidic PGM ore: Implications for froth stability and gangue management
Autorzy:
Manono, M. S.
Corin, K.
Wiese, J.
Powiązania:
https://bibliotekanauki.pl/articles/110603.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
entrainment
water quality
froth stability
electrolytes
Depressant behavior
Opis:
Polysaccharide depressants play a crucial role in the flotation of sulfidic PGM bearing ores as they prevent naturally floatable gangue (NFG) from reporting to the concentrate. This action is regarded as critically important because less dilution of the concentrate means lower costs for downstream processes. However, abnormal water conditions such as high concentrations of ions in the flotation system can modify the selectivity of these depressants. It is well known that the existence of selected electrolytes in water can alter the behaviour of some polysaccharide depressants by enhancing their adsorption onto gangue minerals and thereby prevent naturally floatable gangue from moving into the froth phase. Concurrently these same electrolytes may enhance frothability owing to their stabilising effect on the bubbles within the system. Plant water at various ionic strengths was investigated against sodium carboxymethyl cellulose (CMC) dosages in order to understand electrolyte-depressant interactive effects during the flotation of a Merensky ore in a batch flotation cell, using entrainment, rate of NFG recovery, and total gangue recovery as proxies. The study showed that the NFG recovery per unit mass of water decreased with increasing ionic strength at all CMC dosages, however the total amount of gangue reporting to the concentrate increased with increasing ionic strength at all CMC dosages. Thus, this paper considers the effects of both ionic strength and CMC dosage within flotation. It further investigates whether any interactive effects exist between froth stability and entrainment when considered simultaneously.
Źródło:
Physicochemical Problems of Mineral Processing; 2018, 54, 4; 1253-1265
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Emulsja oleju napędowego jako paliwo alternatywne
Emulsified diesel as an alternative fuel
Autorzy:
Pacholski, P.
Błaszczyk, M.
Sęk, J.
Powiązania:
https://bibliotekanauki.pl/articles/134690.pdf
Data publikacji:
2016
Wydawca:
ADVSEO
Tematy:
water-in-Diesel emulsion
alternative fuel
emulsion stability
microexplosion
Opis:
Emulsified water-in-Diesel fuel is a solution that helps to reduce emissions of nitrogen oxides and particulate matters in compression-ignition engines. The biggest advantage of this fuel is a possibility to introduce it to older generation units without any modifications. The presented solution allows the mixture to be burned more complete which results in less soot formation. However, the practical application of this fuel is limited mainly because its limited stability. In this article we review the following issues connected with water-in diesel fuel: its production, stability, influence on engine performance and environmental benefits. The main aspect of this paper is to review the advantages related to better combustion of such emulsion and reduction in emission of health hazardous substances.
Źródło:
Technical Issues; 2016, 4; 62-67
2392-3954
Pojawia się w:
Technical Issues
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stabilności składu chemicznego wód leczniczych ze Zdroju Głównego w Krzeszowicach
Assessment of stability of curative waters chemical composition from Zdrój Główny in Krzeszowice
Autorzy:
Szczepańska-Plewa, J.
Kmiecik, E.
Drzymała, M.
Powiązania:
https://bibliotekanauki.pl/articles/2062846.pdf
Data publikacji:
2009
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
jakość wody
stabilność
trendy
Krzeszowice
stability
trends
water quality
Opis:
Zdrój Główny w Krzeszowicach ujmuje wody podziemne z utworów mioceńskich. Eksploatacja ujęcia prowadzona jest z przerwami od 1780 roku. Wody te wykorzystywane są wyłącznie na cele lecznictwa balneologicznego. Badania jakości wód ze Zdroju Głównego w Krzeszowicach prowadzone są przez Katedrę Hydrogeologii i Geologii Inżynierskiej AGH od 2002 roku. Próbki pobierane są w odstępach miesięcznych. Składniki chemiczne (17 składników) oznaczane są w laboratorium KHGI metodą ICP-AES (PN-EN ISO 11885:2001), natomiast H2S oznaczany jest w akredytowanym laboratorium Wojewódzkiego Inspektoratu Ochrony Środowiska w Krakowie, zgodnie z normąPN-C-04566.03:1982. W okresie od 31.01.2004 do 31.03.2008 pobrano ogółem 51 próbek. Ocenę stabilności składu chemicznego wód ze Zdroju Głównego w Krzeszowicach przeprowadzono dla trzech składników głównych, decydujących o typie hydrogeochemicznym: S04/2-, Ca2+, Mg2+ oraz składnika swoistego - siarkowodoru (H2S). Do identyfikacji obserwacji odstających zastosowano wykresy skrzynkowe. W celu weryfikacji rozkładu opisującego dane wykorzystano test Shapiro-Wilka. Ocenę stabilności oznaczeń przeprowadzono z wykorzystaniem metody kart kontrolnych (Szczepańska, Kmiecik,1998, 2005). Z przeprowadzonej analizy uzyskano następujące wnioski: stężenia głównych składników: SO4/2-, Ca2+ i Mg2+ w wodach ze Zdroju Głównego w Krzeszowicach mieszczą się w przedziale x+=2delta a zatem należy je uznać za stabilne; składniki te wpływają na typ hydrogeochemiczny wody - ich stężenia stanowią więcej niż 20% mval; stwierdzono rosnący trend wartości stężeń siarkowodoru w czasie, jednak na podstawie analizy przeprowadzonej z wykorzystaniem programu GWSTAT stwierdzono, że z prawdopodobieństwem 95% nie jest on statystycznie istotny.
Zdrój Główny in Krzeszowice intakes sulfide waters from Miocene deposit. Exploitation of this intake has run since the 1780. Water from Zdrój Główny is being used only for balneological treatment. Since the 2002 Department of Hydrogeology and Geology Engineering (AGH - University of Science and Technology) has led up continuous monitoring of its water quality. Average interval between consecutive samplings was ca. one month. Samples were filtered through membrane filter (0.45 micro/m) and transported to laboratory. Chemical analyses of 17 elements were performed with ICP-AES method (PN-EN ISO 11885:2001) and H2S determination were performed in the accredited laboratory according to norm PN-C-04566.03:1982. Between January 2004 and March 2008 51 samples were collected. The assessment of stability was performed for components, which influence on the hydrogeochemical type of water: SO4/2- , Ca2+, Mg2+ and H2S (RMZ, 2006). To identify and reject outliers there were used Box-and-Whisker Plots. Verification of data distribution was made on the base of results from the Shapiro-Wilk Test. Control charts (Szczepańska, Kmiecik, 1998, 2005) were used to assess the stability of examined components. On the basis of this analysis the following information was derived: the content of SO4/2- , Ca2+ and Mg2+ in water from Zdrój Główny in Krzeszowice is stable (most of values are in range x- 2delta x+ 2delta); SO4/2-, Ca2+, Mg2+ influences on the hydrogeochemical type of water (their content is greater than 20% mval); the upward trend for H2S was detected, however detailed analysis with GWstat programme showed, that this trend is statisticaly non-significant (for 95% confidence level).
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2009, 436, z. 9/2; 497-506
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspectives from literature on the influence of inorganic electrolytes present in plant water on flotation performance
Autorzy:
Manono, M. S.
Corin, K.
Wiese, J.
Powiązania:
https://bibliotekanauki.pl/articles/110721.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
electrolytes
flotation reagents
froth stability
physicochemical interaction
water quality
Opis:
The interaction of inorganic electrolytes with reagents in the flotation of sulphidic PGM bearing ores is not well explored. It has been shown that specific inorganic electrolytes such as Ca2+ and SO42- can affect the wettability of gangue minerals. These could also hinder the adsorption of collectors onto valuable minerals and concurrently enhance or retard froth stability. This presents a challenge as regards understanding what the overarching or controlling mechanisms of interaction between electrolytes, reagents and minerals are as well as predicting how flotation performance will be affected. This review shows that studies in literature have simplified the question of electrolyte-reagent-mineral interactions and that current approaches have not provided fundamental solutions to the challenge of water quality. It is proposed that the complexity of the flotation system requires an in-depth knowledge of the individual electrolyte-reagent-mineral interactions so as to establish whether there are any dominant or synergistic interactions. Such in-depth knowledge should enable the development of pulp chemistry control measures against water quality variations in flotation.
Źródło:
Physicochemical Problems of Mineral Processing; 2018, 54, 4; 1191-1214
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność koagulacji kontaktowej w usuwaniu substancji biogennych z wody
Efficiency of contact coagulation in removing biogenic substances from water
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237355.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
stabilność biologiczna wody
koagulacja kontaktowa
substancje organiczne
biogeny organiczne
biogeny nieorganiczne
biological stability of water
contact coagulation
organic matter
organic nutrients
inorganic nutrients
Opis:
Jednym z głównych warunków, jakie należy spełnić, aby zapobiec wtórnemu rozwojowi mikroorganizmów (głównie bakterii) w sieci wodociągowej jest zapewnienie stabilności biologicznej wody wprowadzanej do systemu dystrybucji. W tym celu z oczyszczanej wody muszą być usunięte w jak największym stopniu nieorganiczne związki azotu i fosforu oraz biodegradowalne rozpuszczone substancje organiczne (BRWO), a głównie ich frakcje przyswajalne przez mikroorganizmy (PWO). W artykule przedstawiono wyniki badań nad skutecznością procesu koagulacji kontaktowej w usuwaniu organicznych i nieorganicznych substancji biogennych z mieszaniny wody podziemnej (po napowietrzaniu) i powierzchniowej (po mikrocedzeniu). Stwierdzono, że koagulacja kontaktowa siarczanem żelaza(III) przyczyniła się do znacznego usunięcia fosforanów z wody. Nieorganiczne związki azotu były w tym procesie usuwanie w znacznie mniejszym stopniu. Jednocześnie najmniej skutecznie usuwana była z wody biodegradowalna frakcja związków organicznych, a najskuteczniej nierozpuszczony i rozpuszczony węgiel organiczny. Wykazano, że proces koagulacji kontaktowej w analizowanym przypadku nie zapewnił usunięcia substancji biogennych do wartości zapewniających stabilność biologiczną wody oczyszczonej.
An essential prerequisite for preventing the regrowth of microorganisms (specifically bacteria) in the water-pipe network is the biological stability of the water supplied to the distribution system. To achieve this goal, it is necessary to aim at the highest possible removal of inorganic nitrogen compounds, inorganic phosphorus compounds and biodegradable dissolved organic carbon (BDOC) - particularly their fractions assimilable for microorganisms (AOC) - from the water being treated. In this work, contact coagulation was investigated for efficiency in removing biogenic substances from a mixture of groundwater (after aeration) and surface water (after microfiltration). The study produced the following results. Contact coagulation with iron(III) sulfate provided noticeable removal of phosphates, and much lower removal of inorganic nitrogen compounds. At the same time, the lowest removal efficiency was obtained for the biodegradable fraction of organic compounds, and the highest extent of removal for insoluble organic carbon. It has been demonstrated that in the case under analysis the contact coagulation process failed to provide a reduction in biogenic substances to such a value that would guarantee a biological stability of the treated water.
Źródło:
Ochrona Środowiska; 2010, 32, 2; 3-7
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ dodatku prekursorów cieczy jonowych z anionami wodorosiarczanowymi (VI) i siarczanowymi (VI) na potencjał wydzielania tlenu i wodoru
Influence of addition of ionic liquids precursors with bisulphate (VI) and sulphate (VI) anions on hydrogen and oxygen evolution potential
Autorzy:
Kopczyński, K.
Baraniak, M.
Lota, G.
Pernak, J.
Giszter, R.
Fryder, M.
Powiązania:
https://bibliotekanauki.pl/articles/1215357.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
ciecz jonowa
potencjał wydzielania wodoru i tlenu
trwałość termodynamiczna wody
podstawniki alkilowe
ionic liquid
gas evolution potential
thermodynamic stability of water
alkyl substituents
Opis:
Zbadano wpływ dodatku prekursorów czwartorzędowych amoniowych cieczy jonowych o podstawnikach alkilowych na nadpotencjał wydzielania tlenu i wodoru na elektrodach z węgla szklistego i platyny. Badane prekursory cieczy jonowych różniły się długością jednego z podstawników alkilowych. Znaleziono optymalną długość podstawnika, zapewniającą znaczne zwiększenie nadpotencjału wydzielania gazów. Sprawdzono również, jak zmiana anionu z wodorosiarczanowego (VI) na siarczanowy (VI) wpływa na właściwości tych cieczy. Wykazano, że prekursory cieczy jonowych z anionem siarczanowym (VI) posiadają gorsze właściwości pod względem rozszerzenia przedziału trwałości potencjałowej wody w stosunku do analogów z anionem wodorosiarczanowym (VI).
Influence of addition of precursors of quaternary ammonium ionic liquids on overpotential of oxygen and hydrogen evolution reactions was examined on glassy carbon and platinum electrodes. Ionic liquids differ in length of one of the alkyl chains. Optimal length of alkyl chain, which ensures high increase of gas evolution reaction overpotential was found. Influence of anion change, from bisulphate (VI) to sulphate (VI), was also verified. It was concluded that ionic liquids with sulphate (VI) anions has lower ability to enhance electrochemical stability window of water than ionic liquids with bisulphate (VI) ones.
Źródło:
Chemik; 2016, 70, 9; 509-514
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ mieszania wody podziemnej z różnych pięter wodonośnych na jej stabilność chemiczną i biologiczną w sieci wodociągowej
Impact of mixing groundwaters from different formations on their chemical and biological stability in the water-pipe network
Autorzy:
Bray, R.
Sokołowska, A.
Jankowska, K.
Olańczuk-Neyman, K.
Powiązania:
https://bibliotekanauki.pl/articles/237361.pdf
Data publikacji:
2011
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda podziemna
sieć wodociągowa
stabilność biologiczna
stabilność chemiczna
groundwater
water-pipe network
biological stability
chemical stability
Opis:
Przedstawiono wyniki badań nad wpływem mieszania wody czwarto-rzędowej (oczyszczonej) i wody kredowej (niepoddanej oczyszczaniu) w sieci wodociągowej na jej stabilność chemiczną i biologiczną. Oznaczenie ogólnej liczby bakterii żywych i martwych w próbkach wody wykonano w preparatach mikroskopowych wybarwionych fluorochromem (DAPI). Badania chemicznej stabilności wody na podstawie potencjalnej zdolności do wytrącania z niej osadu wykonano w warunkach przepływowych, mierząc absorpcję światła nadfioletowego i widzialnego przechodzącego przez warstwę odkładającego się osadu. Ustalono, że zmieszanie wody kredowej z wodą czwartorzędową, pomimo utrzymania jakości zgodnej z wymaganiami, może skutkować utratą jej stabilności chemicznej i biologicznej i prowadzić do powstawania osadów oraz namnażania się mikroorganizmów w sieci wodociągowej. Wysoki wzrost liczby bakterii odnotowany w wodzie zmieszanej w temperaturze 10 oC (3,35-krotny) oznacza, że niska temperatura wód podziemnych nie gwarantuje zachowania stabilności biologicznej wody w sieci wodociągowej.
Groundwater from Quaternary aquifers (treated) and groundwater from Cretaceous aquifers (untreated) was mixed and tested for chemical and biological stability in water-pipe networks. The total number of live and dead bacteria in the water samples was determined using microscopic preparations stained with fluorochrome (DAPI method). Chemical stability examinations, based on the potential ability of the water to precipitate sediments, were conducted under flow conditions, by measuring both the absorption of UV light and the absorption of visible light passing through the layer of the depositing sediment. The study has produced the following finding. Mixing Cretaceous and Quaternary ground-waters may not only result in the loss of their chemical and biological stability, but also induce sediment deposition and microbial regrowth in the water-pipe network, even when the water quality required is maintained. The considerable (3.35-fold) increase in the number of bacteria observed at 10 oC indicates that the temperature of the mixed groundwaters is insufficiently high to guarantee their biological stability in the water-pipe network.
Źródło:
Ochrona Środowiska; 2011, 33, 3; 19-23
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of monovalent cations on soil structure. Part I. Results of an Iranian soil
Autorzy:
Farahani, Elham
Emami, Hojat
Keller, Thomas
Fotovat, Amir
Khorassani, Reza
Powiązania:
https://bibliotekanauki.pl/articles/972451.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
aggregate stability
dispersible clay
potassium
soil pore size
water retention
Opis:
This study investigated the impact of monovalent cations on clay dispersion, aggregate stability, soil pore size distribution, and saturated hydraulic conductivity on agricultural soil in Iran. The soil was incubated with treatment solutions containing different concentrations (0-54.4 mmol l-1) of potassium and sodium cations. The treatment solutions included two levels of electrical conductivity (EC=3 or 6 dS m-1) and six K:Na ratios per electrical conductivity level. At both electrical conductivity levels, spontaneously dispersible clay increased with increasing K concentration, and with increasing K:Na ratio. A negative linear relationship between percentage of water-stable aggregates and spontaneously dispersible clay was observed. Clay dispersion generally reduced the mean pore size, presumably due to clogging of pores, resulting in increased water retention. At both electrical conductivity levels, hydraulic conductivity increased with increasing exchangeable potassium percentage at low exchangeable potassium percentage values, but decreased with further increases in exchangeable potassium percentage at higher exchangeable potassium percentage. This is in agreement with earlier studies, but seems in conflict with our data showing increasing spontaneously dispersible clay with increasing exchangeable potassium percentage. Our findings show that clay dispersion increased with increasing K concentration and increasing K:Na ratio, demonstrating that K can have negative impacts on soil structure.
Źródło:
International Agrophysics; 2018, 32, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutki braku stabilności biologicznej wody wodociągowej
Lack of Biological Stability and the Implication it has for Tap Water Quality
Autorzy:
Świderska-Bróż, M.
Powiązania:
https://bibliotekanauki.pl/articles/236444.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
stabilność biologiczna
biofilm
tap water quality
biological stability
Opis:
Omówiono parametry składu wody oraz procesy oczyszczania współdecydujące o jej biologicznej stabilności. Wykazano, że brak stabilności biologicznej wody wprowadzanej do sieci wodociągowej jest jedną z głównych przyczyn wtórnego fizyczno-chemicznego i bakteriologicznego zanieczyszczenia wody wodociągowej podczas jej transportu do odbiorców. Wykazano, że w wodzie niestabilnej biologicznie przebiegają takie zjawiska, jak wtórny rozwój mikroorganizmów unoszonych z wodą lub zasiedlających wewnętrzne powierzchnie przewodów wodociągowych (tzw. biofilm), biokorozja intensyfikująca korozję elektrochemiczną metali, hamowanie powstawania powłok antykorozyjnych, bądź ich rozpuszczanie, zwiększone zużycie środków dezynfekcyjnych i uwalnianie produktów korozji metali do wody. Zjawiska te są powodem wtórnego zanieczyszczenia wody podczas jej przebywania w systemie wodociągowym.
The parameters of the water composition and the treatment processes contributing to its biological stability are specified. It has been shown that the lack of biological stability of the water entering the pipe network is one the major factors responsible for the recontamination (both physicochemical and bacteriological) of the tap water during transport to the users. Biologically unstable water favours the occurrence of the following phenomena: regrowth of microorganisms floating in the water or colonizing the pipe interior (biofilm), biocorrosion enhancing the electrochemical corrosion of metals, inhibition of anticorrosive film formation, solubilization of anticorrosive films, release of metal corrosion products into the water, etc. They all are contributions to the recontamination of water during residence in the water supply system.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 4, 4; 7-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of seed priming and aging on physiological performance of chickpea under different irrigation treatments
Autorzy:
Hosseinzadeh-Mahootchi, Ayda
Ghassemi-Golezani, Kazem
Powiązania:
https://bibliotekanauki.pl/articles/2199712.pdf
Data publikacji:
2012-12-20
Wydawca:
Instytut Hodowli i Aklimatyzacji Roślin
Tematy:
chickpea
hydro-priming
membrane stability
relative water content
stomatal conductance
Opis:
A sub-sample of chickpea (Cicer arietinum L. cv.ILC482) seeds was kept  as control and two other sub- samples were aged at 40 °C for 3 and 5 days. Consequently, three seed lots with different levels of vigor were provided. These seed lots were soaked in distilled water at 15°C for 12 and 18 hours and then dried back to initial moisture content at a room temperature of 20-22°C. Then seeds were sown in the field as split plot factorial based on RCB design. Hydro-priming improved leaf chlorophyll content index of plants from different  seed  lots.  Hydro-priming also  enhanced  stomatal  conductance of plants  from all  seed  lots under all  irrigation  levels,  but this  advantage for plants  from low vigor seed  lots  particularly under limited  irrigations  was higher  than that  for other  treatments. Plants  from high vigor seed  lot under different irrigation treatments had higher relative water content, compared with those from low vigor seed lots. Hydro-priming improved relative water content, membrane stability and grain yield of chickpea plants from different  seed lots  under various  irrigation treatments. It was concluded that hydro-priming to some extent can repair aged seeds and improve their performance under different irrigation treatments.
Źródło:
Plant Breeding and Seed Science; 2012, 67; 13-26
1429-3862
2083-599X
Pojawia się w:
Plant Breeding and Seed Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comprehensive Assessment of the Impact of the Almaty Wastewater Storage System on the State of Groundwater
Autorzy:
Ospanov, Kairat
Absametov, Malis
Murtazin, Yermek
Iskanderov, Rustam
Powiązania:
https://bibliotekanauki.pl/articles/2086383.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water disposal
waste water
storage system
impact on groundwater
filtration
stability of loose massif
pollution
Opis:
This article presents the results of studies on the comprehensive assessment pertaining to the peculiarities of nutrition, accumulation, transit and discharge of groundwater in the adjacent territory of the Sorbulak reservoir. The information about the waste water storage was presented. The results of the analysis and decryption of satellite images, as well as the results of aerial photography of the territory of the Sorbulak were presented. The results of field route studies of the work area were presented to identify the external manifestations of directional filtration, areas of exits to the daytime surface of groundwater. The results of the calculation of the filtration flow controlled by the Sorbulak storage lake, unloading through the western side of the plateau into the Kurty River, were presented.
Źródło:
Journal of Ecological Engineering; 2022, 23, 4; 75--84
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Snizhenie agregativnojj ustojjchivosti kolloidnojj primesi prirodnykh vod aktivirovannym rastvorom koaguljanta sulfata aljuminija
Decline of aggregate stability of colloid admixture of natural waters by the activated solution of coagulant of sulfate of aluminium
Autorzy:
Ehpojan, S.
Dushkin, S.
Powiązania:
https://bibliotekanauki.pl/articles/77180.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
water treatment
admixture
colloid
natural water
aggregate stability
coagulant
aluminium sulphate
electrokinetic potential
sewage treatment plant
drinking water
Opis:
Influence of the activated solution of coagulant of sulfate aluminium is examined on the decline of electrokinetic potential of colloid admixtures at cleaning of natural waters. It is set that the decline of aggregate stability of colloid admixtures of natural waters allows intensifying work of sewage treatment plants at preparation of drinking-water.
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stabilności wody wprowadzanej do sieci wodociągowej
Stability Assessment of Water Introduced into the Water Supply Network
Autorzy:
Wolska, M.
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236953.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
tap water
chemical stability
biostability
water aggressiveness
nutrients
woda z kranu
stabilność chemiczna
sieć wodociągowa
Opis:
Both chemical and biological stability of water was assessed from the three water supply networks using different water sources: surface, infiltration and the mixed (surface and groundwater). The oxidizing agent content, Langelier and Ryznar corrosivity indexes and water aggressiveness index were chosen as criteria for the water chemical stability assessment. Water biostability was determined on the basis of nutrient content: inorganic nitrogen and phosphate forms as well as biodegradable organic carbon (BDOC). It was established that in respect of chemical stability, the waters had some common characteristics such as dissolved oxygen and chlorine oxidizing agent content, conducive to the electrochemical corrosion process, as well as lack of an aggressive carbon dioxide with the concurrent lack of calcium-carbonate equilibrium supporting scale formation. The Ryznar index values were indicative of the corrosive potential of water; the surface water samples belonged to a clearly ‘corrosive’ range. The biological instability was a constant feature of the tested waters and it was the excessive inorganic nitrogen content that was the most conducive to the bacterial regrowth in the water. In either case, disinfectant content was determined to be inadequate with regard to prevention of biological recontamination of water, which was in contrast with its excess in relation to water corrosivity criterion.
Chemiczna i biologiczna stabilność wody została oceniona w trzech sieciach wodociągowych wykorzystujących różne źródła wody: powierzchniowe, infiltracji i mieszane (powierzchniowych i podziemnych).
Źródło:
Ochrona Środowiska; 2015, 37, 4; 51-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki współdecydujące o potencjale powstawania i rozwoju bio-filmu w systemach dystrybucji wody
Factors in the potential of biofilm formation and growth in water distribution systems
Autorzy:
Świderska-Bróż, M.
Powiązania:
https://bibliotekanauki.pl/articles/236880.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
system wodociągowy
biofilm
stabilność chemiczna
stabilność biologiczna
środek dezynfekcyjny
water distribution system
chemical stability
biological stability
disinfectant
Opis:
Dokonano przeglądu problematyki powstawania biofilmu na wewnętrznej powierzchni rurociągów i instalacji wodociągowych. Omówiono przyczyny i skutki braku stabilności chemicznej i biologicznej wody w systemie wodociągowym. Podkreślono, że biofilm stwarza problemy techniczne i ekonomiczne, a przede wszystkim stanowi poważne zagrożenie jakości sanitarnej wody dostarczanej odbiorcom. Wykazano, że przyczyn współdecydujących o obecności i rozwoju biofilmu w systemach dystrybucji wody jest wiele. Związane są one nie tylko z jakością wody wprowadzanej do sieci wodociągowej, ale również z właściwościami materiałów instalacyjnych, warunkami hydraulicznymi panującymi podczas transportu wody do odbiorców, stanem technicznym i sanitarnym wszystkich elementów systemu dystrybucji oraz zachodzącymi w nim zjawiskami. Z uwagi na interakcje tych uwarunkowań, a przede wszystkim na najczęściej niemożliwą całkowitą ich eliminację, niezbędna jest skuteczna kontrola rozwoju biofilmu. Jest ona równoznaczna z zapewnieniem w całym systemie dystrybucji obecności środka dezynfekcyjnego, którego rodzaj i wymagana ilość mogą być różne w poszczególnych systemach dystrybucji wody. Spełnienie tego wymogu jest szczególnie trudne w przypadku rozległych i wyeksploatowanych systemach wodociągowych oraz tych, w których powstały już obrosty biologiczne.
The paper gives an account of the problems associated with the formation and growth of a biofilm on the internal surfaces of water pipes and water supply systems. Consideration is given to the causes and implications of chemical and biological instability of the water in the distribution system. Biofilms not only create technological and economic problems, but also pose a serious risk of deteriorating the quality of the water supplied to the user. The causes underlying the occurrence and growth of the biofilm in the water distribution system are manifold. Apart from those pertaining to the quality of the water entering the distribution system, they include the properties of the materials from which particular installations have been constructed, the hydraulic conditions that occur during water transport to the user, the technical and sanitary condition of all elements being part of the water distribution system, as well as any of the phenomena involved. Considering all the concomitant interactions - as well as the fact that in most instances they are difficult to eliminate to the extent desired (if at all) - a viable control of the biofilm's growth becomes a must. To efficiently control biofilm growth, it is necessary to provide the water distribution systems with continuous supply of disinfectants. (The type and quantity of the disinfectant may vary from one water distribution system to another.) Such requirement is difficult to fulfil specifically in the case of spacious, obsolete water-supply systems.
Źródło:
Ochrona Środowiska; 2010, 32, 3; 7-13
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Protein thermal stabilization in aqueous solutions of osmolytes
Autorzy:
Bruździak, Piotr
Panuszko, Aneta
Jourdan, Muriel
Stangret, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1038842.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
water structure
protein stability
circular dichroism
FT-IR spectroscopy
DFT calculations
Opis:
Proteins' thermal stabilization is a significant problem in various biomedical, biotechnological, and technological applications. We investigated thermal stability of hen egg white lysozyme in aqueous solutions of the following stabilizing osmolytes: Glycine (GLY), N-methylglycine (NMG), N,N-dimethylglycine (DMG), N,N,N-trimethylglycine (TMG), and trimethyl-N-oxide (TMAO). Results of CD-UV spectroscopic investigation were compared with FTIR hydration studies' results. Selected osmolytes increased lysozyme's thermal stability in the following order: Gly>NMG>TMAO≈DMG>TMG. Theoretical calculations (DFT) showed clearly that osmolytes' amino group protons and water molecules interacting with them played a distinctive role in protein thermal stabilization. The results brought us a step closer to the exact mechanism of protein stabilization by osmolytes.
Źródło:
Acta Biochimica Polonica; 2016, 63, 1; 65-70
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sedimentation of water dispersed systems of acrylate copolymers in xylene
Autorzy:
Makarewicz, E.
Zalewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/779032.pdf
Data publikacji:
2008
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
polimery
dyspersja wodna
sedymentacja
stabilność
polymer
water colloid dispersions
sedimentations
stability
Opis:
Methyl methacrylate - butyl acrylate - methacrylic acid copolymer and butyl methacrylate - methacrylic acid amide copolymer of a different segmental structure were stabilised with non-ionic and anionic surfactants. Gel chromatography, viscosimetry, tensiometry, conductometry and sedimentation methods were applied to define the properties of the synthesized copolymers, surfactants in water solutions and water dispersions. The types and the properties of the phases being in a state of sedimentation balance were also determined. The obtained experimental data were interpreted and justified by using the copolymer and surfactants properties. The existing correlations were pointed out. The obtained results show that the stability of a disperse system considerably depends on the structure of the copolymer. The MMA/BA/MAA copolymer has monomeric units of elastic butyl acrylate. Segments containing these monomeric units adsorb surfactants much better and form more stable water disperse systems. However, the MBA/AMAA copolymer with the polarity of amide group of methacrylamide makes disperse systems less stable.
Źródło:
Polish Journal of Chemical Technology; 2008, 10, 3; 29-34
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical analysis on experiments in transformation of deep-water-waves
Autorzy:
Wilde, P.
Powiązania:
https://bibliotekanauki.pl/articles/241349.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
water wave
stability
transformation
wave groups
non-linear Schrödinger differential equation
Opis:
The aim of the paper is to discuss the usefulness of the non-linear Schrödinger differential equation in the study of transformations of progressive deep water waves. Its solution compared with a regular Stokes type wave is essentially restricted to the first order approximation of the second one. The difference is that the Schrödinger equation introduces the concepts of a carrier wave and complex amplitude. In this way the dispersion relation of the third order Stokes expansion is taken into account. The analysis starts with regular, non breaking Stokes waves with large amplitudes as measured in our laboratory. The third order approximation is considered and compared with the corresponding solution of the Schrödinger equation. Then small periodic modifications are introduced in the time series fed into the control system of the generator. The approximation by trigonometric series is applied and the simplified analysis of superposition of very small modifications is used (higher powers of modifications are neglected). The Schrödinger non-linear equation is used in this analysis. The comparison of experimental and calculated envelopes is good, but for the surface elevations in space it is not as good. The approximation by trigonometric series is also applied to study the case of larger modifications. Finally the solutions of the Schrödinger equation corresponding to perfect solitons, are compared with the experimental data for cases where the measured surface elevations look almost like periodic solitons. This gives a reasonable approximation of the real behaviour in a very short space interval. It is not easy to get a good numerical description for the wave problem discussed as the waves are physically unstable. The results of the presented research will be used to establish an effective numerical procedure, stress the approximations introduced by the application of the Schrödinger differential equation and show how the theoretical solutions should be compared with the measured data.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2005, 52, 3; 213-242
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Filtracja i stateczność jako główne parametry oceny stanu wału przeciwpowodziowego
Water filtration and slope stability is as the prime parameters of flood banks
Autorzy:
Kołodziejczyk, U.
Powiązania:
https://bibliotekanauki.pl/articles/2062876.pdf
Data publikacji:
2011
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wały przeciwpowodziowe
filtracja
stateczność skarp
flood banks
water filtration
slope stability
Opis:
Od czasu powodzi tysiąclecia, która miała miejsce w dorzeczu Odry w 1997 r., prowadzi się intensywną modernizację wałów przeciwpowodziowych. Wykorzystuje się tutaj szereg nowoczesnych technologii. Artykuł przedstawia skuteczność modernizacji wałów przeciwpowodziowych za pomocą mat bentonitowych. Zagadnienie to scharakteryzowano na podstawie obliczeń filtracji i stateczności korpusu wału przeciwpowodziowego, który jest projektowany na lewym brzegu lubuskiego odcinka Odry, wzdłuż 528,6–532,0 km biegu rzeki. W obliczeniach uwzględniono dwa przypadki: (a) wał bez przegrody filtracyjnej oraz (b) wał uszczelniony przesłoną z mat bentonitowych. Wykonane obliczenia filtracji sugerują, że zastosowanie ekranów przeciwfiltracyjnych w postaci mat bentonitowych może obniżyć filtrację nawet o 99%.
Since the millennium flooding, which happened in Odra basin in 1997, intensive modernization of flood banks has been carried out. The catastrophic flood in 1997, called the flood of the century, had the greatest range. Many different types of sealing materials are used during modernization of the flood banks of Odra River. This article shows the effectiveness of flood banks modernization with the usage of bentomat which is produced by CETCO Poland. This problem has been described on the basis of filtration and stability calculations of the flood banks body localized on left bank of Odra River in Lubuskie voivodship. The described section is located along 528,6-532,0 km of the course of the river. In calculations two cases were taken into consideration: (a) flood bank without filtration barrier and (b) flood bank sealed with bentomat. The calculations showed that the usage of waterproof screens made of bentonite mats can reduce filtration by 99%.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2011, 446 (2); 369--378
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Molecular dynamics simulations study of nano bubble attachment at hydrophobic surfaces
Autorzy:
Jin, J.
Dang, L. X.
Miller, J. D.
Powiązania:
https://bibliotekanauki.pl/articles/109533.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
molecular dynamics simulations (MDS)
film stability
bubble attachment
interfacial water structure
Opis:
Bubble attachment phenomena are examined using Molecular Dynamics Simulations (MDS) for the first time. The simulation involves a nitrogen nano bubble containing 906 nitrogen molecules in a water phase with 74,000 water molecules at molybdenite surfaces. During a simulation period of 1 ns, film rupture and displacement occurs. The attached nanobubble at the hydrophobic molybdenite face surface results in a contact angle of about 90º. This spontaneous attachment is due to a “water exclusion zone” at the molybdenite face surface and can be explained by a van der Waals (vdW) attractive force, as discussed in the literature. In contrast, the film is stable at the hydrophilic quartz (001) surface and the bubble does not attach. Contact angles determined from MD simulations are reported, and these results agree well with experimental and MDS sessile drop results. In this way, film stability and bubble attachment are described with respect to interfacial water structure for surfaces of different polarity. Interfacial water molecules at the hydrophobic molybdenite face surface have relatively weak interactions with the surface when compared to the hydrophilic quartz (001) surface, as revealed by the presence of a 3 Å “water exclusion zone” at the molybdenite/water interface. The molybdenite armchair-edge and zigzag-edge surfaces show a comparably slow process for film rupture and displacement when compared to the molybdenite face surface, which is consistent with their relatively weak hydrophobic character.
Źródło:
Physicochemical Problems of Mineral Processing; 2018, 54, 1; 89-101
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of balancing of anthropogenic changes of relief and water conditions in the Tatra Mountains
Autorzy:
Radziewicz, Tomasz
Mikulska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2030353.pdf
Data publikacji:
2006-06-01
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Tematy:
anthropopressure
relief
water conditions
Tatra Mountains
natural system
catchment area
system stability
Opis:
During its entire utilisation history - lasting several hundred years - the area of the Tatra Mountains underwent multidirectional anthropopressure. As the result, all components of their natural environment have been transformed, including relief and water conditions.The analysis of the literature on this topie conducted by the author, as well as his observations performed in the area, confirmed the assumption that transformations caused by human actions developed with varying intensity and admitted various forms depending on the area of action and the magnitude of means applied. The transformation scalę presented here estimates the influence of anthropopressure on the stability of the catchment area systems of larger Tatra streams, partial catchment areas of their confluents and selected slope surfaces. In systems, where the limits of persistence were not exceeded, stability was ensured by natural processes compensating for the conseąuences of anthropopressure. In systems where stability was disturbed, planned preventive measures are necessary.
Źródło:
Miscellanea Geographica. Regional Studies on Development; 2006, 12; 125-130
0867-6046
2084-6118
Pojawia się w:
Miscellanea Geographica. Regional Studies on Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zmian jakości wody w przewodach wodociągowych z wykładziną cementową
Water quality variations in cement-lined water-pipe networks
Autorzy:
Wąsowski, J.
Kowalski, D.
Kowalska, B.
Kwietniewski, M.
Zawilska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236692.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
sieć wodociągowa
wykładzina cementowa
stabilność chemiczna
zanieczyszczenie wody
tap water
water-pipe network
cement lining
chemical stability
water contamination
Opis:
Badania przeprowadzone w instalacji modelowej zasilanej wodą podziemną wykazały, że woda kontaktująca się z wykładziną cementową stopniowo traciła właściwości agresywne i nabierała zdolności do wytrącania węglanu wapnia. Świadczyło to o przechodzeniu składników cementu z wykładziny do wody wodociągowej. Poza głównymi składnikami (wapń, magnez, glin) stwierdzono obecność w wodzie także pierwiastków śladowych (cynk, bar, chrom, ołów, nikiel, kobalt), przy czym nie były to ilości znaczące. Wykazano, że wymywanie pierwiastków z cementu przebiegało intensywniej do wody poddawanej chlorowaniu. Końcowa zawartość wszystkich oznaczonych pierwiastków w wodzie po kontakcie z wykładziną cementową była znacznie poniżej wartości dopuszczalnych w wodzie przeznaczonej do spożycia.
Experiments performed in a model pipe system fed with underground water demonstrated that tap water exposed to cement-lining gradually lost its corrosive properties and continued to develop its potential for calcium carbonate precipitation. This was an indication that cement components were released from the lining into the water residing in the pipes. Apart from its main components (calcium, magnesium and aluminum), the water contained small quantities of trace elements (zinc, barium, chromium, lead, nickel and cobalt). The study produced the following findings: leaching of elements from the cement lining was enhanced upon exposure to chlorinated water, and the final concentration values of all the elements detected in the water after contact with the cement lining were much lower than those permissible for drinking water.
Źródło:
Ochrona Środowiska; 2012, 34, 1; 53-58
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wtórnego zanieczyszczenia niestabilnej chemicznie wody w systemie dystrybucji
Recontamination of Chemically Unstable Water in the Distribution System
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237225.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
korozyjność wody
stabilność chemiczna
system dystrybucji
produkty korozji
water corrosivity
chemical stability
distribution system
tap water
corrosion products
Opis:
Brak stabilności chemicznej wody wprowadzanej do systemu dystrybucji jest przyczyną pogarszania jej jakości, w większości próbek wody nawet do poziomu ponadnormatywnego. W badaniach wykazano, że największe zmiany składu fizyczno-chemicznego wody dotyczyły zawartości żelaza ogólnego i nierozpuszczonego, a także barwy i mętności wody. Dodatkowo, wraz ze wzrostem odległości punktu poboru wody od zakładu oczyszczania wody, wzrastało zużycie chloru wolnego, co stwarzało warunki do rozwoju mikroorganizmów. Stwierdzono, że procesy zachodzące podczas transportu wody w sieci wodociągowej powodowały intensyfikację agresywności korozyjnej wody, co sprzyjało rozpuszczaniu osadów zgromadzonych w rurociągach, będących źródłem zanieczyszczenia wody głównie produktami korozji żeliwnych i stalowych przewodów wodociągowych.
Chemical instability is the main contributor to the deterioration of water quality during transport in the distribution system. In the investigated water distribution system, the most noticeable changes in the water quality parameters were those in total and insoluble iron concentrations, colored matter content and turbidity. The persistence of low disinfectant concentrations promoted bacterial regrowth and water contamination due to the metabolism of bacterial by-products. The processes that occured in the distribution system during water transport enhanced the corrosivity of the water, which favored the dissolution of pipe encrustation. The dominating pollutants were found to be products of cast iron and steel pipe corrosion.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 4, 4; 34-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy woda wodociągowa musi być dezynfekowana chemicznie?
Does drinking water have to be chemically disinfected?
Autorzy:
Olejnik, A.
Nawrocki, J.
Powiązania:
https://bibliotekanauki.pl/articles/236658.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
jakość wody
substancje organiczne
oczyszczanie wody
stabilność biologiczna
sieć wodociągowa
water quality
natural organic matter
water treatment
biological stability
water distribution system
Opis:
Rozwój wiedzy w dziedzinie technologii oczyszczania wody pozwala na takie przygotowanie wody przed jej dystrybucją, że nie jest konieczne stosowanie chemicznej dezynfekcji. Zakłady wodociągowe w Polsce poniosły olbrzymie nakłady finansowe na zmiany technologii oczyszczania, aby sprostać zwiększonym wymaganiom jakościowym wody przeznaczonej do spożycia. Podstawowym celem zakładu wodociągowego jest dostarczenie wody bezpiecznej mikrobiologicznie, przy czym bezpieczeństwo to w dużych sieciach wodociągowych osiąga się dzięki stosowaniu chemicznej dezynfekcji wody za pomocą chloru, dwutlenku chloru lub chloraminy. Obecność chemicznych środków dezynfekcyjnych w wodzie jest często społecznie trudna do akceptacji ze względu na wrażenia organoleptyczne, a także z uwagi na powstawanie tzw. ubocznych produktów dezynfekcji. Coraz lepsze zrozumienie procesów chemicznych i biologicznych zachodzących podczas oczyszczania wody oraz jej dystrybucji powoduje, że nowoczesna technologia może zapewnić konsumentom wodę wodociągową bezpieczną mikrobiologicznie, a jednocześnie pozbawioną pozostałości chemicznych środków dezynfekcyjnych. W ten sposób pracują wodociągi i sieci dystrybucyjne w Berlinie, Zurychu, Amsterdamie, Rotterdamie i innych miastach zachodniej Europy. W artykule postawiono pytanie, jakie warunki należy spełnić, aby chemiczna dezynfekcja wody nie była konieczna. W tym celu omówiono warunki zapewniające wysoką stabilność biologiczną wody, co w konsekwencji umożliwi zaniechanie jej dezynfekcji chemicznej.
Knowledge development in the field of water treatment enables preparation of water prior to its distribution in such a way that chemical disinfection is no longer required. Public water systems in Poland incurred huge expenses for changes in water treatment technology in order to fulfill increasing quality requirements regarding potable water. The basic aim of public water system is to provide microbially safe water for human consumption. This safety in large water supply networks is obtained thanks to chemical disinfection with chlorine, chlorine dioxide or chloramine. Presence of chemical disinfectants in water is often socially difficult to accept due to their negative organoleptic properties as well as formation of the so called byproducts of disinfection. Continuous progress in understanding of chemical and biological processes taking place during water treatment and its distribution enables modern technology to provide consumers with microbially safe drinking water, devoid of chemical disinfectant residues. This is how waterworks and distribution networks operate in Berlin, Zurich, Amsterdam, Rotterdam and other cities of Western Europe. The question asked in this paper referred to the conditions necessary to be fulfilled for chemical water disinfection not to be required. For this purpose, conditions ensuring high biological water stability, and as a result allowing chemical disinfection to be abandoned, were discussed.
Źródło:
Ochrona Środowiska; 2013, 35, 4; 3-8
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Firmness and stability of plantain fruits under ambient temperatures
Autorzy:
Asoegwu, S.N.
Powiązania:
https://bibliotekanauki.pl/articles/25721.pdf
Data publikacji:
1996
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
firmness
ambient temperature
physical property
plantain
Musa
stability
nutrition
Africa
fruit
water content
Źródło:
International Agrophysics; 1996, 10, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-term effects of spent coffee grounds on the physical properties of two Mediterranean agricultural soils
Autorzy:
Cervera-Mata, A.
Martin-Garcia, J.M.
Delgado, R.
Parraga, J.
Sanchez-Maranon, M.
Delgado, G.
Powiązania:
https://bibliotekanauki.pl/articles/2082515.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
organic amendment
soil aggregate stability
soil water retention
soil aggregate size
SEM images
Opis:
We investigated the short-term effects of spent coffee grounds on the physical properties of two Mediterranean agricultural soils (Calcisol and Luvisol). The in vitro assay was performed with two spent coffee grounds doses (60 and 240 Mg ha-1), two incubation times (30 and 60 days) and two modalities: with and without lettuce seedlings (Lactuca sativa var. longifolia). Spent coffee grounds addition increased water retention at -33 and -1500 kPa, and decreased bulk density and plant-available water content. With spent coffee grounds, the percentage of macroaggregates increased, the percentage of meso- and microaggregates decreased and the structural stability of all types of aggregates increased. The stereomicroscopy images showed that: the structural aggregates were rounded, the porosity increased by 316%, the structure was ordered into smaller aggregates, the incorporation of spent coffee grounds particles could occur in intraped cracks and spent coffee grounds particles could act as a binding agent. Scanning electron microscopy also showed that spent coffee grounds particles interacted with mineral particles and integrated into soil structure; moreover, fungal hyphae also developed on many spent coffee grounds particles. If spent coffee grounds effects are compared with those described in the literature for other organic amendments, the same trend was observed in most of the soil physical properties although with a different intensity, principally with regard to structural stability.
Źródło:
International Agrophysics; 2019, 33, 2; 205-216
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temporal stability of electrical conductivity in a sandy soil
Autorzy:
Pedrera-Parrilla, A.
Brevik, E.C.
Giraldez, J.V.
Vanderlinden, K.
Powiązania:
https://bibliotekanauki.pl/articles/26163.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
temporal stability
electrical conductivity
sandy soil
soil texture
soil water content
spatial variability
Źródło:
International Agrophysics; 2016, 30, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of landscape structure on the quality index of surface waters
Wpływ struktury krajobrazu na wskaźniki jakości wody
Autorzy:
Fedoniuk, Tetyana P.
Fedoniuk, Roman H.
Romanchuk, Ludmila D.
Petruk, Anatolyy A.
Pazych, Viktor M.
Powiązania:
https://bibliotekanauki.pl/articles/292648.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
degradation
landscape stability
surface water
the Dnieper-River cascade
water quality
degradacja
jakość wody
kaskada Dniepru
stabilność krajobrazu
wody powierzchniowe
Opis:
The article focuses on the problem of structure degradation and ecosystem functioning – the urgency that identifies the relevance of operations at a strategic level aimed at providing the integrated assessment of ecological stability of water. Determination of water quality indicators were divided into blocks according to the criteria of salt composition, according to chemical saprobological indicators and the content of specific substances of toxic and radiation action. According to the results of block analysis, the integrated ecological index of water quality was determined by the dependence of water quality on the indicators of ecological stabilization of the landscape and the structure of biotechnical elements. The article determines the relationships between worsening quality of surface waters and stabilization or destabilization of the landscape structure. The research was conducted on medium and large streamflows on the Right Bank of Polesie region of the Dnieper- River cascade within which the tracts of land were identified and the landscape ecological stability (CESL1) and landscape biotechnical elements coefficients (CESL2) were determined. The retrospective analysis was performed of the surface water features on the Right Bank of Polesie region of the Dnieper- River cascade and the main trends in salt block indicators, trophic and saprobiological block indicators, and in the content of toxic and radioactive substances at observation sites were estimated. Based on obtained data, the integrated assessment in trends of surface water quality on the Right Bank of Polesie region of the Dnieper- River cascade was made and the main parameters and scale of stabilization and destabilization of landscape impact on the water quality formation were defined.
W artykule skupiono się na problemie degradacji struktury i funkcjonowaniu krajobrazu, tj. pilnej potrzebie odniesienia się do strategicznych działań mających zapewnić zintegrowaną ocenę ekologicznej stabilności wód. Określenie wskaźników jakości wody realizowano w blokach według kryteriów: skład mineralny wód, wskaźniki chemiczne i saprobiologiczne oraz stężenie substancji toksycznych i radioaktywnych. W wyniku analiz oznaczono zintegrowany wskaźnik jakości wód i ustalono zależność między jakością wody a wskaźnikami stabilizacji krajobrazu i strukturą elementów biotechnicznych. W artykule określono zależność między pogarszającą się jakością wody a stabilizacją bądź destabilizacją struktur krajobrazu. Badania prowadzono na średnich i dużych ciekach prawobrzeżnej kaskady Dniepru w regionie Polesia, gdzie wyznaczono pasy ziemi i oznaczono dla nich współczynnik stabilności ekologicznej (CESL1) oraz współczynnik krajobrazowych elementów biotechnicznych (CESL2). Przeprowadzono retrospektywną analizę właściwości wód powierzchniowych obszaru badań i ustalono trendy zmian wskaźników zasolenia, wskaźników chemicznych i saprobiologicznych oraz stężenia substancji toksycznych i radioaktywnych. Na podstawie uzyskanych danych wykonano zintegrowaną ocenę jakości wód na obszarze prawobrzeżnej kaskady Dniepru oraz zdefiniowano główne parametry i wpływ skali stabilizacji lub destabilizacji krajobrazu na jakość wód.
Źródło:
Journal of Water and Land Development; 2019, 43; 56-63
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the stability and reliability of the water treatment plant in Nowy Sącz using control cards
Autorzy:
Śliz, Paulina
Bugajski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2073749.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
control cards
pollution reduction efficiency
stability of wastewater treatment
technological reliability
water treatment plant
Opis:
The subject of the study was to evaluate the stability and reliability of the sewage treatment plant in Nowy Sącz. The scope of the analysed indicators included the main indicators of wastewater contamination: BOD5(biochemical oxygen demand), CODCr (chemical oxygen demand), total suspended solids (TSS), total nitrogen (Ntot), and total phosphorus (Ptot). The operation stability of the sewage treatment plant in Nowy Sącz was determined on the basis of control cards x for 24 observations made in the period 2018-2019 (2 years). Moreover, the technological reliability of the tested sewage treatment plant (WN) was determined based on the values of the analysed pollution indicators in treated sewage and their permissible values. On the basis of the conducted analyses, full stability of the removal process of most of the analysed contaminants was found. In no case was there any crossing of the control lines, only a single grouping of samples above the help line in the case of total nitrogen, which could indicate a periodical disturbance in the stability of the removal process of this compound. On the basis of the obtained values of the reliability coefficient, which were below WN=1.00, reliable operation of the analysed facility was found, with a high degree of reduction (ƞ) of the analysed pollutants. The method of determining the technological reliability and stability of the treatment plant with the use of control cards is an effective and easy tool for detecting any disturbances and instabilities in the processes taking place in the tested facility. It enables the operator to take quick action to remove them, thus ensuring a safe wastewater treatment process for the environment and human health.
Źródło:
Journal of Water and Land Development; 2022, 52; 251--256
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies