Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "voltage vector" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Predictive torque control of induction motor drive with reduction of torque and flux ripple
Autorzy:
Kiani, Babak
Mozafari, Babak
Soleymani, Soodabeh
Mohammadnezhad Shourkaei, Hosein
Powiązania:
https://bibliotekanauki.pl/articles/2086858.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FS-MPTC
induction motor
duty ratio
voltage vector
torque
flux ripples
silnik indukcyjny
cło
wektor napięcia
moment obrotowy
fala strumienia
tętnienie momentu obrotowego
Opis:
The continuing efforts for reduction of the torque and flux ripples using Finite Set Model Predictive Direct Torque Control methods (FS-MPDTC) have been currently drowning a great attention from the academic communities and industrial applications in the field of electrical drives. The major problem of high torque and flux ripples refers to the consideration of just one active voltage vector at the whole control period. Implementation of two or more voltage vectors at each sampling time has recently been adopted as one of the practical techniques to reduce both the torque and flux ripples. Apart from the calculating challenge of the effort control, the parameter dependency and complexity of the duty ratio relationships lead to reduction of the system robustness. those are two outstanding drawbacks of these methods. In this paper, a finite set of the voltage vectors with a finite set of duty cycles are employed to implement the FS-MPDTC of induction motor. Based on so-called Discrete Duty Cycle- based FS-MPDTC (DDC-FS-MPDTC), a base duty ratio is firstly determined based on the equivalent reference voltage. This duty ratio is certainly calculated using the command values of the control system, while the motor parameters are not used in this algorithm. Then, two sets of duty ratios with limit members are constructed for two adjacent active voltage vectors supposed to apply at each control period. Finally, the prediction and the cost function evaluation are performed for all of the preselected voltage vectors and duty ratios. However, the prediction and the optimization operations are performed for only 12 states of inverter. Meanwhile, time consuming calculations related to SVM has been eliminated. So, the robustness and complexity of the control system have been respectively decreased and increased, and both the flux and torque ripples are reduced in all speed ranges. The simulation results have verified the damping performance of the proposed method to reduce the ripples of both the torque and flux, and accordingly the experimental results have strongly validated the aforementioned statement.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 4; e137727, 1--13
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A computationally low burden MPTC of induction machine without prediction loop and weighting factor
Autorzy:
Kiani, Babak
Powiązania:
https://bibliotekanauki.pl/articles/2173663.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
MPTC
model predictive torque control
induction motor
duty ratio
voltage vector
lookup table
weighting factor
modelowa predykcyjna kontrola momentu obrotowego
silnik indukcyjny
współczynnik wypełnienia impulsu
wektor napięcia
tabela przeglądowa
współczynnik ważenia
Opis:
This paper presents a novel method to overcome problems of finite set-model-based predictive torque control (MPTC) which has received a lot of attention in the last two decades. Tuning the weighting factor, evaluating a large number of switching states in the loop of the predictive control, and determining the duty cycle are three major challenges of the regular techniques. Torque and flux responses of deadbeat control have been developed to overcome these problems. In our method, firstly, the prediction stage is performed just once. Then, both the weighted cost function and its evaluation are replaced with only simple relationships. The relationships reduce torque ripple and THD of stator current compromisingly. In the next step, the length of the virtual vector is used to determine the duty cycle of the optimum voltage vector without any additional computations. The duty ratio does not focus on any relation or criteria minimizing torque or flux ripple. As a result, torque and flux ripples are reduced equally. The proposed duty cycle is calculated by using a predicted virtual voltage vector. Hence, no new computation is needed to determine the proposed duty cycle. Simulation and experimental results confirm both the steady and dynamic performance of the proposed method in all speed ranges.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 4; art. no. e142050
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simple three-level neutral point voltage balance control strategy based on SVPWM
Autorzy:
Bo, G.
Shanmei, Ch.
Yi, Q.
Powiązania:
https://bibliotekanauki.pl/articles/141238.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
space vector
neutral point voltage
voltage offset
PWM
Opis:
The unbalance of the neutral point voltage is an inherent problem of three-level neutral-point-clamped (NPC) inverter, the effect of neutral point voltage balancing which is caused by voltage vector is analyzed, and the relationship of the voltage offset and neutral point voltage is studied in this paper. This paper proposes a novel neutral point balance strategy for three-level NPC inverter based on space vector pulse width modulation (SVPWM). A voltage offset is added to the modulation wave, and a closed-loop neutral point voltage balance control system is designed. In the control system, the dwelling time of synthesis voltage vectors for SVPWM is varied to solve the problem of the unbalance of the neutral point voltage, the sequence of the voltage vectors maintains unchanging. Simulation and experimental results show the neutral point voltage balancing control strategy based on SVPWM is effective.
Źródło:
Archives of Electrical Engineering; 2013, 62, 1; 15-23
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An improved space vector modulation strategy for common-mode voltage reduction in matrix rectifier
Autorzy:
Liu, X.
Zhang, Q.
Hou, D.
Powiązania:
https://bibliotekanauki.pl/articles/950664.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
matrix converter
space vector modulation
common-mode voltage
Opis:
The matrix rectifier modulated by the classical space vector modulation (SVM) strategy generates common-mode voltage (CMV). The high magnitude and high du/dt of the CMV causes serious problems such as motor damage, electromagnetic noise and many others. In this paper, an improved SVM strategy is proposed by replacing the zero vectors with suitable couple of active ones that substantially eliminate the CMV. Theoretical analysis proves that the proposed strategy can reduce the amplitude of the CMV to half of the original value. In addition, the quality of the input and output waveforms is not affected by extra active vectors. Simulation and experimental results demonstrate the feasibility and effectiveness of the proposed strategy are shown.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 93-106
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage induced by currents in power-line sagged conductors in nearby circuits of arbitrary configuration
Autorzy:
Budnik, K.
Machczyński, W.
Szymenderski, J.
Powiązania:
https://bibliotekanauki.pl/articles/140488.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power line
catenary
vector potential
overhead circuit
induced voltage
mutual inductance
Opis:
The study presents a calculation method of the voltage induced by power-line sagged conductor in an inductively coupled overhead circuit of arbitrary configuration isolated from ground. The method bases on the solution utilizing the magnetic vector potential for modeling 3D magnetic fields produced by sagging conductors of catenary electric power lines. It is assumed that the equation of the catenary exactly describes the line sag and the influence of currents induced in the earth on the distribution of power line magnetic field is neglected. The method derived is illustrated by exemplary calculations and the results obtained are partially compared with results computed by optional approach.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 227-236
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obserwator prędkości silnika asynchronicznego pracującego w układzie z filtrem sinusoidalnym
Speed control of asynchronous motor in system with output LC filter
Autorzy:
Guziński, J.
Powiązania:
https://bibliotekanauki.pl/articles/153952.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
falownik napięcia
filtr sinusoidalny
sterowanie wektorowe
voltage source inverter
LC filter
vector control
Opis:
W układach napędowych z tranzystorowymi falownikami napięcia występują niekorzystne zjawiska wynikające z dużych stromości napięć zasilających silnik. Aby ich uniknąć między falownik a silnik włącza się filtr bierny wygładzający przebiegi napięć i prądów silnika. Włączenie takiego filtru sinusoidalnego powoduje zmianę struktury układu i powoduje konieczność modyfikacji układu sterowania silnika i estymatorów zmiennych stanu układu. W niniejszym referacie przedstawiono układ napędowy w sterowaniu którego uwzględniono filtr sinusoidalny.
In the electric drives with voltage inverters appears disadvantageous phenomena come from high du/dt in motor supply voltage. To prevent that phenomena the passive filter is introduced between motor and inverter. Filter assure smoothed voltages and current in the electric motor. When the filter is used the structure of the system is changed so the control and estimation structure should be changed also. In the paper the modified electric drive with output LC filter is presented.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 4, 4; 27-31
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Predictive-SVM control method dedicated to an AC/DC converter with an LCL grid filter
Autorzy:
Dmitruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/200760.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-phase voltage converter
model predictive control
space vector modulation
infinite control set
Opis:
This paper presents simulation and laboratory test results of an implementation of an infinite control set model predictive control into a three-phase AC/DC converter. The connection between the converter and electric grid is made through an LCL filter, which is characterized by a better reduction of grid current distortions and smaller (cheaper) components in comparison to an L-type filter. On the other hand, this type of filter can cause strong resonance at specific current harmonics, which is efficiently suppressed by the control strategy focusing on the strict control input filter capacitors voltage vector. The presented method links the benefits of using linear control methods based on a space vector modulator and the nonlinear ones, which result in excellent control performance in a steady state as well as in a transient state.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 5; 1049-1056
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DC-link voltage balancing in cascaded H-Bridge converters
Autorzy:
Lewicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/141491.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascaded H-Bridge converter
DC-link voltage balancing
space-vector pulse width modulation
Opis:
In this paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches on proposed control strategy are presented in the paper.
Źródło:
Archives of Electrical Engineering; 2014, 63, 3; 439-455
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O kształcie napięcia wyjściowego falownika pomocniczego pojazdu trakcyjnego na podstawie analizy z wykorzystaniem wektora przestrzennego
The shape of output volt- i age of the auxiliary inverter of traction vehicle based on the analysis using the spatial vector
Autorzy:
Żarnowski, Roman
Płachtyna, Omelian
Kłosowski, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/34595792.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
napięcie wyjściowe
falownik napięcia
pojazd trakcyjny
wektor przestrzenny
transformator trójfazowy
napięcie trójfazowe
output voltage
voltage inverter
traction
space vector
three-phase transformer
three-phase voltage
Opis:
Współczesne układy elektryczne często są zasilane ze źródeł napięcia odkształconego pochodzącego z przekształtników energoelektronicznych. Artykuł jest opisem pracy pewnego nowego układu trójfazowego kaskadowego falownika napięcia z trójfazowym transformatorem, jako źródła napięcia bez wyższych harmonicznych do rzędu 10 włącznie, lub w wersji rozbudowanej bez harmonicznych do rzędu 22, na podstawie analizy z wykorzystaniem pojęcia wektora przestrzennego. Źródło trójfazowego napięcia o takiej jakości napięcia jest wystarczające do zasilenia obwodów pomocniczych prądu przemiennego pojazdu trakcyjnego, jak i może zasilać sieć autonomiczną, w tym silniki indukcyjne.
The modern electrical systems are often supplied from the deformed i voltage sources derived from the energy-electronic converters. The article is a description of operation of a i new three- phase cascade inverter of 1 voltage with the three-phase transformer as the voltage source without i the higher harmonics up to the order of 10 inclusive or in the extended t version without harmonics up to the order of 22 based on the analysis with s using the notion of spatial vector. Three-phase voltage source with such voltage quality is sufficient to supply a the AC auxiliary circuits of the traction vehicle and it can power the a autonomous network including the induction motors.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2014, 4; 6-13
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Industrial implementations of control algorithms for voltage inverters supplying induction motors
Autorzy:
Jabłoński, Mariusz
Borkowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1841309.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
open mining
sensorless control
vector-controlled
adjustable speed drive
converter system
voltage-feed induction motors
Opis:
This article discusses the most important issues regarding the implementation of digital algorithms for control and drive technology in industrial machines, especially in open mining machines. The article presents the results of tests in which the algorithm and drive control parameter settings were not selected appropriately for voltage-fed induction motors, and where the control speed was not verified by any of the available motoring or simulation methods. We then show how the results can be improved using field-oriented control algorithms and deep parameters analysis for sensorless field-oriented performance.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 475-491
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid-Tied Neutral Point Clamped based Centralised Photovoltaic Inverter with Improved DC Link Voltage Balancing and Harmonic Minimisation Control
Autorzy:
Bhowmick, Supratik
Mukherjee, Debranjan
Maiti, Suman
Chakraborty, Chandan
Powiązania:
https://bibliotekanauki.pl/articles/1955983.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
photovoltaic multilevel inverter
neutral point voltage balancing
space vector pulse width modulation
current harmonic minimisation
Opis:
This paper proposes an improved space vector pulse width modulation (SVPWM) based DC link voltage balancing control of a three-phase three-level neutral point clamped (NPC) centralised inverter supplying the generated power from photo voltaic (PV) array to a three-phase utility grid. Two possible schemes have been developed based on the power conversion stage between PV array and the utility grid namely, two-stage (three-level boost converter three-phase three-level NPC inverter) and single-stage (three-phase three-level NPC inverter alone). The comparison between these two schemes has been thoroughly discussed in terms of the control strategies employed, power loss analysis and efficiency. The performance of the centralised inverter under different modes of operation has been investigated by developing the required control strategies for smooth operation. Using the proposed control strategy, the centralised inverter can be operated as a static synchronous compensator (STATCOM) during night time, if needed. The power loss incurred in the power-electronic converters has been analysed for constant and also for variable ambient temperature. The effectiveness of the centralised inverter as an active filter (AF) has also been verified when a three-phase non-linear load is considered in the system.
Źródło:
Power Electronics and Drives; 2021, 6, 41; 185-203
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Space-vector pulsewidth modulation for a seven-level cascaded H-bridge inverter with the control of DC-link voltages
Autorzy:
Lewicki, A.
Morawiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/200099.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cascade H-bridge inverter
DC-link voltage control
space vector modulation
mostek H
sterowanie napięciem
modulacja
Opis:
A control strategy of DC-link voltages for a seven-level cascaded H-bridge inverter is proposed in this paper. The DC-link voltage balancing is accomplished by an appropriate selection of H-bridges and control of their duty cycles in space-vector modulation (SVM) algorithm. The proposed SVM method allows to maintain the same voltage level on all inverter capacitors. Regardless of the balancing function, the SVM strategy makes it possible to generate the output voltage vector properly also in the case where the DC-link voltages are not balanced. The results of simulation and experimental investigations are presented in the paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 5; 619-628
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of complex sliding window discrete Fourier transformation in current and voltage distortion analysis in three-phase circuits
Wykorzystanie dyskretnej transformaty Fouriera zmiennej zespolonej ze ślizgającym oknem do analizy odkształceń prądów i napięć w układach trójfazowych
Autorzy:
Grugel, P.
Powiązania:
https://bibliotekanauki.pl/articles/194124.pdf
Data publikacji:
2011
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
dyskretna Transformata Fouriera zmiennej zespolonej ze ślizgającym oknem
selektywna filtracja aktywna
analiza widmowa wektora wodzącego
odkształcone przebiegi prądu i napięcia
Complex Sliding Window Discrete Fourier Transformation
selective active power filtration
position vector spectrum analysis
voltage and current distorted waveforms
Opis:
The article concerns the aspects of vector analysis of current and voltage distorted waveforms in three-phase circuits from the point of higher harmonic content. Apart from that, the work contains the results of the analysis of current's vector harmonic based on the complex SDFT. These results have been obtained after having conducted a simulation. The article also tackles the proposal of accelerating the SDFT algorithm in order to facilitate its implementation in real-time systems.
Artykuł przedstawia aspekty wektorowej analizy odkształconych przebiegów prądów i napięć w układach trójfazowych pod kątem zawartości wyższych harmonicznych. Praca zawiera również wyniki analizy harmonicznej wektora prądu opartej o transformatę Fouriera zmiennej zespolonej ze ślizgającym oknem (complex SDFT) uzyskane na drodze symulacji oraz propozycję przyspieszenia algorytmu SDFT w celu ułatwienia jego implementacji w układach pracujących w czasie rzeczywistym.
Źródło:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2011, 16; 27-41
0209-0570
Pojawia się w:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies