Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "voltage measurement" wg kryterium: Temat


Wyświetlanie 1-31 z 31
Tytuł:
High frequency metrology for intracardiac ablation: in-vivo results
Autorzy:
Rouane, A.
Bru, P.
Powiązania:
https://bibliotekanauki.pl/articles/221888.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance matching
voltage measurement cell
current measurement cell
high frequency energy
Opis:
Cardiac Radiofrequency (RF) ablation is a commonly used clinical procedure for treating many cardiac arrhythmias. However, the efficacy of RF ablation may be limited by two factors: small ventricular lesions and impedance rise, leading to coagulum formation and desiccation of tissue. In this paper, a high frequency (HF) energy ablation system operating at 27.12 MHz based on an automated load matching system was developed. A HF energy matched probe associated to the automated impedance matching device ensures optimal transfer of the energy to the load. The aim of this study was to evaluate this energy for catheter ablation of the atrioventricular junction. In vivo studies were performed using 10 sheep to characterize the lesions created with the impedance matching system. No cardiac perforation was noted. No thrombus was observed at the catheter tip. Acute lesions ranged from 3 to 45 mm in diameter (mean šSD = 10.3š10) and from 1 to 15 mm in depth (6.7š3.9), exhibiting a close relationship between HF delivered power level and lesion size. Catheter ablation using HF current is feasible and appears effective in producing a stable AV block when applied at the AV junction and large myocardial lesions at ventricular sites.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 603-610
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Improved Method of Busbar Voltage Reconstruction from Signals of Electric Field Sensors Installed in an Indoor MV Substation
Autorzy:
Borkowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/220871.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
voltage measurement
signal reconstruction
modelling
parameters identification
simulated annealing
Opis:
This paper presents an improved method for the reconstruction of busbar voltage waveforms from signals acquired by a system of electric field (EF) sensors located in an indoor medium voltage substation. In the previous work [8], the authors proposed the use of black-box models in the form of artificial neural networks (ANNs) for this task. In this paper it is shown that a parametric model of the system of EF sensors can reconstruct voltages with much lower errors, provided that it is accurately identified. The model identification is done by minimization of a nonlinear goal function, i.e. mean squared error (MSE) of voltage reconstruction. As a result of examining several optimization techniques, the method based on simulated annealing extended with a simplex search, is proposed. The performance of the model identified with this method is at least 8 times better in terms of MSE and at least 12 times better in terms of frequency domain errors than the best one of concurrent ANNs.
Źródło:
Metrology and Measurement Systems; 2018, 25, 1; 71-86
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frequency synchronization error correction by using DFT in sinusoidal voltage measurements
Autorzy:
Krajewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/114200.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
correction of synchronization error
accurate RMS voltage measurement
DFT algorithm
Opis:
The paper presents a method of correcting a frequency synchronization error in the sinusoidal voltage measurement. Correction is performed by changing a frequency of the measured signal on the basis of the respectively determined synchronization error by using DFT. Carried out simulation experiments indicate that the correction can theoretically improve the accuracy of measurement of the RMS voltage to the level below 1 ppm. The results of measurements taken by a highly accurate voltmeter Agilent 3458 confirm the conclusions of the simulation, that it is possible to repeatedly reduce the frequency synchronization error by applying the developed correction method in the voltage measurement.
Źródło:
Measurement Automation Monitoring; 2016, 62, 7; 218-220
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar mocy prądu przemiennego metodami elektronicznymi
Power measurement non-sinusoidal current using electronic methods
Autorzy:
Zajkowski, K.
Duer, S.
Powiązania:
https://bibliotekanauki.pl/articles/315355.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
prąd przemienny
teoria Budeanu
pomiar mocy
pomiar napięcia
alternating current
Budeanu theory
voltage measurement
power measurement
Opis:
W artykule omówiono metodę pomiaru mocy czynnej i biernej według Budeanu dla prądu przemiennego przy wykorzystaniu algorytmów elektronicznych. Zaproponowany sposób pomiaru mocy może być zastosowany w urządzeniach energetycznych w układach bezpieczeństwa w transporcie.
The article discusses the method for measuring active and reactive power by Budeanu for alternating current using electronic algorithms. The proposed method of measuring the power may be used in power equipment systems for transport security.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1505-1508
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of insulating parameters of oil transformer by time and frequency methods
Autorzy:
Gutten, Miroslav
Kucera, Matej
Brncal, Peter
Sebok, Milan
Korenciak, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/327187.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
insulating system
transformer
return voltage measurement
frequency dielectric spectroscopy
system izolacyjny
transformator
metoda spektroskopii częstotliwościowej
Opis:
In the paper is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers. In the first part of the paper is described base theory about measurement and diagnostics insulating part (oil and paper) of transformers. In the other two parts of the paper is presented experimental results of the diagnostic measurement for the transformer 22/0.4 kV at constant temperature. Specifically, in the second part is described measuring time method of insulating diagnostics - return voltage measurement (RVM). This method is used for analysis of condition of paper moisture of high-voltage equipment. In the third part is described measuring method of insulating frequency diagnostics - frequency domain spectroscopy (FDS). This method is used for analysis insulating condition of high-voltage equipment with insulating oil-paper. The both measuring methods are unique in terms of analysis of insulating system of oil power transformers. In comparison with other methods, the RVM and FDS methods it is possible comparison and evaluate the moisture state of the dielectric paper of the power transformer with high reliability and accurate. Their reliability in determining moisture in paper was shown by determining the same result (3.5%) on the same measured transformer.
Źródło:
Diagnostyka; 2020, 21, 4; 51-56
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podstawy analizy harmonicznej odkształconych przebiegów prądów i napięć w sieciach zasilających
The prinzip of spectrum analyse of deformated current and voltage in supply electrical networks
Autorzy:
Pawłowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/186414.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
pomiar napięcia i mocy
pomiar wyższych harmonicznych napięcia
pomiar wyższych harmonicznych prądu
measurement of upper harmonics of current
measurement of upper harmonics of voltage
power and voltage measurement
Opis:
W artykule przeprowadzono krytyczną analizę metod pomiaru wyższych harmonicznych prądu i napięcia, porównując różne teorie odnośnie do definicji mocy. Podano podstawy analizy harmonicznej wraz z przykładami, ze szczególnym naciskiem na wpływ zastosowania różnych okien do analizy harmonicznej. Sformułowano odpowiednie wnioski praktyczne.
In the paper is given analyse of methodology of measurement of upper harmonics of current and voltage. It was made a summary of different theory of electrical power and their problems. There are given the prinzip of spectrum analyse with exemples. There were describes influence of different types of windows on the results of analyse. Finally given conclusions.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2010, R. 48, nr 7, 7; 17-23
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja wzorców transferowych AC/DC w Centralnym Wojskowym Ośrodku Metrologii
AC/DC transfer standards calibration at the Central Military Calibration Laboratory
Autorzy:
Piróg, P.
Górecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/208762.pdf
Data publikacji:
2017
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
wzorce transferowe AC/DC
różnica transferowa AC/DC
termiczne przetworniki wartości skutecznej
pomiar napięcia przemiennego
AC/DC converters
AC/DC difference
thermal voltage converters
TVCs
AC voltage measurement
Opis:
W artykule omówiono metodę kalibracji wzorca transferowego Fluke 5790A z użyciem transferowego wzorca odniesienia Fluke 792A, stosowaną w Centralnym Wojskowym Ośrodku Metrologii. Przedstawiono równanie pomiaru, budżet niepewności oraz ocenę wpływu wielkości wejściowych na niepewność pomiaru. Dokonano oceny spójności pomiarowej uzyskanych wyników kalibracji z wynikami ostatniej kalibracji w laboratorium Fluke.
The article discusses the method used at the Central Military Calibration Laboratory to calibrate Fluke 5790 AC/DC transfer standard with the reference transfer standard Fluke 792A. It presents the measurement equation and the uncertainty budget. The contribution of uncertainty components in the measurement uncertainty has been presented. The metrological traceability has been evaluated by comparing calibration results with the results in the last Fluke certificate of calibration.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2017, 66, 4; 203-213
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monolityczne układy konwerterów sigma-delta do pomiaru wartości skutecznej napięcia i ich porównanie ze scalonymi konwerterami klasycznymi
The present monolithic sigma-delta converters for root-mean-square voltage measurement and their comparison to classic monolithic integrated RMS converters
Autorzy:
Korytkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/277296.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
element monolityczny
elektroniczny układ pomiarowy
modulator sigma-delta
pomiar wartości skutecznej napięcia
monolithic element
electronic measuring circuit
sigma-delta modulator
root-mean-square voltage measurement
Opis:
W pracy omówiono zasadę działania współczesnych monolitycznych układów konwerterów sigma-delta stosowanych do formowania analogowego sygnału pomiarowego o wartości skutecznej napięcia. Dokonano przeglądu właściwości monolitycznych układów konwerterów sigma-delta do pomiaru wartości skutecznej napięcia i porównano z właściwościami monolitycznych klasycznych konwerterów stosowanych do takich pomiarów. Istotnymi zaletami monolitycznych układów konwerterów sigma-delta do pomiaru wartości skutecznej są: duża dokładność formowania analogowego wyjściowego sygnału pomiarowego, bardzo mały pobór mocy na wejściu oraz szerokie pasmo częstotliwościowe mierzonego napięcia wejściowego.
The monolithic sigma-delta converters are very useful for measurement root-mean-square time-varying voltage circuits. The fig. 1 shows converter block diagram, which got possibility to describe the mathematical function for calculation RMS value of input AC voltage. The fig. 2 shows block diagram of multiplier-divider circuit containing identical two controlled elements having the very same controlled amplification. In the fig. 3 is shown the circuit diagram of sigma-delta modulator and characteristic of comparator, which is a part of the modulator. According to fig. 3 was formulated equation (15) as the characteristic description of multiplier-divider circuits, which is the main element of sigma-delta true RMS converter for input voltage measurement. The part 3 of this paper describes the parameters review of monolithic RMS converters. The table 1 presents the parameter values of selected group RMS converters, which are delivered by several much known firms. The converters parameters analysis shows, that monolithic sigma-delta converters have very good qualities in the parameter field of accuracy, minimal signal power consumption and wide frequency band of input measurement signals.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 7-8; 84-89
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza właściwości filtru Kalmana w pomiarze zespolonego stosunku napięć
Analysis of Kalman filter properties on complex voltage ratio measurement
Autorzy:
Krajewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/153149.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
analiza właściwości filtru Kalmana
pomiar zespolony w stosunku napięć
analysis of filter properties
complex voltage ratio measurement
Opis:
W pracy przedstawiono analizę właściwości filtru Kalmana zastosowanego w pomiarze zespolonego stosunku napięć sinusoidalnych. Analizowano wpływ wybranych parametrów przetwarzania analogowo-cyfrowego oraz parametrów algorytmu na dokładności estymacji modułu i argumentu zespolonego stosunku napięć sinusoidalnych. Właściwości filtru Kalmana porównano z właściwościami metody najmniejszych kwadratów (MNK). Przedstawiono wyniki symulacji komputerowych i badań doświadczalnych.
In the paper analysis of Kalman filter properties on complex voltage ratio measurement are presented. Influence of chosen analog to digital conversion parameters and algorithm parameters on estimate accuracy of the magnitude and argument of complex sinusoidal voltage ratio is analysed. Kalman filter properties are compared with least square mean (LSM) algorithms properties. Simulation end experimental results are described.
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 6, 6; 51-53
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary mocy chwilowej w diagnostyce łożysk silników indukcyjnych
Instantaneous power measurements in induction motor bearing diagnostics
Autorzy:
Dzwonkowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/156016.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
diagnostyka łożysk
pomiary napięcia
pomiary prądu
moc chwilowa
widmo mocy chwilowej
wibracje
silnik indukcyjny
bearing diagnostics
voltage measurement
current measurements
instantaneous power spectrum
vibration
induction motor
Opis:
W artykule przedstawiono zagadnienia dotyczące diagnostyki łożysk z wykorzystaniem metody badawczej, opartej na pomiarze i analizie mocy chwilowej pobieranej przez silnik indukcyjny. Przedstawiono przykładowe wyniki wykonanych pomiarów w oparciu o proponowaną metodę oraz przeprowadzono ich analizę. Na podstawie przeprowadzonej analizy sformułowano wnioski dotyczące możliwości wykorzystania proponowanej metody do diagnostyki łożysk.
The paper deals with the issue of bearing diagnostics using the method based on measurements and analysis of a product of instantaneous values of the stator current and supply voltage of induction machines. The introduction of the paper contains general assumptions of the used method and description of the research methodology. The second and third sections present the laboratory stand used for investigations as well as the methodology of the research. The fourth section contains some examples of the measurement results obtained with use of the proposed method and the analysis of these results. The measurements were taken on induction motors. The investigation results for an undamaged machine are shown in Fig. 1, while those for motors with a damaged bearing outer and inner ring are presented in Figs. 2 and 4. The investigation results for a machine with damage of a bearing outer ring for different load torque values are shown in Fig. 6, whereas Figs. 3 and 5 present the vibration measurements of damaged machines. The summary contains the main conclusions concerning the possibility of using the proposed method for bearing diagnostics of induction motors.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1589-1591
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienia wpływu odkształcenia krzywej napięcia sieci na pomiar impedancji pętli zwarciowej
Problems of the influance of voltage waveform distortion on me asurement the short-circuit loop impedance
Autorzy:
Roskosz, R.
Powiązania:
https://bibliotekanauki.pl/articles/151844.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
odkształcenia krzywej napięcia sieci
pomiar impedancji pętli zwarciowej
influance of voltage waveform distortion on measurement
Opis:
W artykule przedstawiono problematykę pomiaru impedancji pętli zwarciowej szczególnie w tych układach niskiego napięcia, gdzie krzywa napięcia w miejscu badania może być odkształcona. Przeprowadzono analizę wpływu wyższych harmonicznych zawartych w napięciu badanym na błędy pomiaru impedancji pętli przy stosowaniu klasycznych metod opartych na pomiarze skutecznych wartosci oraz dla metod wykorzystujących amplitudy mierzonych napięć. Badania i obliczenia błędów pomiaru przeprowadzone zostały dla wybranych typów odkształceń krzywej napięcia oraz dla różnych parametrów obwodu badanego, a przykładowe wyniki badań zaprezentowano w tablicy i na wykresach. Z analizy wynika, że błąd pomiaru może znacznie przekroczyć wartość dopuszczalną przez przepisy. Przeprowadzona analiza umożliwi ocenę, które znane metody i przyrządy mogą być stosowane do wyznaczania impedancji petli przy wyraźnym odkształceniu klrzywej napięcia.
This paper discusses and analyses the effects of supply voltage harmonics on accuracy of power system loop impedance measurement. Special attention is given to the study of impedance measurement methods, which are based on the measurement of arms or maximum voltage values. Examples of measurement error values are presented in the form of a table and curves for different parameters of the tested circuit. The result of this study indicates that under unfavorable measuring condition the measurement error may exceed the permissable value given by standards. An analysis allows for the assesment, which known loop impedance measuring methods and instruments may be use in networks with distinct voltage waveform distortion.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 9, 9; 9-13
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomagane komputerowo stanowisko laboratoryjne do badania właściwości metrologicznych multimetrów na zakresach napięć przemiennych
Computer-assisted laboratory stand for testing metrological properties of multimeters alternating voltage ranges
Autorzy:
Krawiecki, Z.
Odon, A.
Powiązania:
https://bibliotekanauki.pl/articles/153893.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
programowanie
badanie woltomierzy
pomiar napięcia przemiennego
programming
testing of voltmeters
measurement of alternating voltage
Opis:
W pracy opisano stanowisko laboratoryjne ze wspomaganiem komputerowym do badania woltomierzy napięcia przemiennego. Do testów wybrano przyrządy analogowe i cyfrowe z przetwornikami wartości średniej i wartości skutecznej. Źródłem sygnału jest generator Agilent 33120A. Sprawdzanie wskazań przeprowadzane jest dla różnych częstotliwości oraz kształtów przebiegów, w tym silnie odkształconych.
In the paper a laboratory stand for testing voltmeters of alternating voltage is described. Analog and digital voltmeters based on the mean value and root mean square converters have been utilized. The generator Agilent 33120A was used as the source of signals to be measured. Controlling of indications was performed for some different frequencies as well as shapes of the waveforms, including the signals strongly deformed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 710-712
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wieloparametrowy tester elektrycznych parametrów bezpieczeństwa sprzętu elektromechanicznego
Multiparameter tester of electric safety of electromechanical equipment
Autorzy:
Pacholski, K.
Pierzgalski, W.
Szawelko, M.
Szczęsny, A.
Powiązania:
https://bibliotekanauki.pl/articles/157554.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektryczne parametry bezpieczeństwa
pomiar prądu i napięcia
electric safety parameters
measurement of current and voltage
Opis:
W artykule przedstawiono wymagania dotyczące metod badania i kryteriów oceny bezpieczeństwa sprzętu elektrycznego użytkowanego w gospodarstwach domowych i przemyśle. Zaprezentowano ponadto koncepcję nowego systemu pomiarowego przeznaczonego do wyznaczania wartości tych parametrów dla odbiorników jednofazowych i trójfazowych o mocy zawartej w przedziale od 0.1 do kilkudziesięciu kW. Przedstawiony system pomiarowy zbudowany jest z kilku niezależnych modułów (przyrządów), które można zastosować do pomiaru wybranych parametrów oddzielnie i zapewnić zgodność opracowanych metod pomiarowych z wymaganiami normy PN-EN 60335-1:2004. Jego konfigurację określał będzie użytkownik łącząc wybrane moduły z blokiem sterującym.
In the paper there are described requirements concerning the methods of investigations and criteria of evaluation of the electric equipment safety. This equipment is used in households and the industry. The idea of a new measuring system for determining the values of these parameters for single-phase and three-phase receivers at power from the range of 0.1 kW to some kW is also presented. The presented measuring system is built of several independent modules (instruments), which can be used for measuring chosen parameters separately. It ensures that the elaborated measuring methods meet the requirements of standard PN - EN 60335-1:2004. The user can determine the configuration of a measuring system, connecting the chosen modules with a controlling block. Currently produced measuring systems dedicated to determine electric safety parameters do not allow determinuing their values during the tested device operation. The system presented in this paper does not possess this disadvantage.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1104-1106
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of methods applied to measuring the lightning impulse breakdown voltage of insulating pressboard impregnated with mineral oil and natural ester
Autorzy:
Klarecki, Artur
Rózga, Paweł
Stuchała, Filip
Powiązania:
https://bibliotekanauki.pl/articles/2052181.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lightning impulse voltage
high voltage
measurement methods
dielectric liquids
insulating pressboard
Weibull distribution
Opis:
The aim of this paper is to compare three different methods of analysis of results of lightning impulse breakdown voltage measurements of solid materials such as insulating pressboard. These three methods are the series method, the step method and the up-and-down method which are applied to withstand voltage estimation commonly in high voltage engineering. To obtain the data needed for the analysis a series of experimental studies was carried out. It included studies of mineral oil and natural ester impregnating 1 mm of thick cellulose-based pressboard. In order to show the distribution of breakdown voltage the Weibull distribution was additionally applied in data analysis. The results were also assessed from the viewpoint of dielectric liquid used for impregnation. The studies carried out showed that series and step methods give comparable results opposite to the up-and-down method. The latest overstates the results for mineral oil impregnated pressboard and understates for natural ester impregnated pressboard when juxtaposing them with the rest of the methods applied. In addition, there is lack of possibility to assess the withstand voltage for the up-and-down method directly from the vector of random variable. It is possible only as a result of a specially developed equation which always arouses doubt. From the methods applied it seems that the step method can be a great substitution for the series method as intuitive, fast in application and limiting the number of samples in solid insulation material testing.
Źródło:
Metrology and Measurement Systems; 2021, 28, 4; 693-709
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiar mocy elektrycznej w urządzeniach mobilnych
The measure of electrical energy in mobile devices : methods of measuring voltage and current in a sinusoidal electrical circut with using microcontroller device and in analitical way to state power
Autorzy:
Zajkowski, K.
Karpiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/313113.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
pomiar mocy
moc czynna
Arduino
measurement
voltage
current
power
Opis:
W artykule omówiono problem pomiaru mocy elektrycznej w zastosowaniach mobilnych, w tym pojazdach zasilanych elektrycznie. Omówiono sposoby pomiaru mocy przy różnych typach przebiegów napięć i prądów. Przedstawiono propozycję realizacji pomiaru w oparciu o system mikroprocesorowy.
The article discusses the problem of measuring of electrical power in mobile applications, including electrically powered vehicles. Discusses ways to measure power at the different types of voltage and current waveforms. Presented a proposal for the implementation of the measurement system based on microprocessor systems.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 7-8; 478-482
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An AC measurement system for use with resistive temperature sensors
Autorzy:
Rybski, R.
Walkowiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/114103.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
AC resistance thermometry
resistance ratio measurement
complex voltage ratio
Opis:
In the paper, a measurement system based on a universal commercial measuring module of alternating current for accurate temperature measurement by means of resistive temperature sensors is described. There are presented the research results on the basis of which the metrological properties of the system were evaluated. It was shown that this relatively simple measurement system is a competitive solution compared with the most accurate commercial DC measurement systems.
Źródło:
Measurement Automation Monitoring; 2016, 62, 8; 259-261
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komparacja Termicznych Przetworników Wartości Skutecznej metodą dwukanałową - szacowanie niepewności przy przenoszeniu jednostki napięcia AC
Dual - channel comparison of AC-DC Thermal Voltage Converters (TVCs) - uncertainty analysis for AC voltage unit transfer
Autorzy:
Kaźmierczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/155822.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
napięcie AC
spójność pomiarowa
wzorcowanie
niepewność pomiaru
przetworniki termiczne wartości skutecznej
AC voltage
traceability
calibration
measurement uncertainty
thermal voltage converters
Opis:
W artykule przedstawiono rolę, jaką spełniają termiczne przetworniki wartości skutecznej (TVC) dla zapewnienia spójności pomiarowej w zakresie napięć AC niskich częstotliwości (do 1 MHz) w Głównym Urzędzie Miar (GUM). Przedstawiono metodę pomiarową komparacji dwukanałowej stosowaną w GUM do wzorcowania termicznych przetworników AC/DC wartości skutecznej napięcia elektrycznego przemiennego (AC). W drugiej części opisano procedurę szacowania niepewności dla tej metody i przedstawiono przykładowy budżet niepewności. Przedstawiono także przykładowe wyniki porównania wzorcowań przetwornika termicznego przeprowadzonych w GUM i w PTB (Niemcy) potwierdzające poprawność stosowanej metody komparacji.
The paper discusses thermal voltage converters (TVC) as reference standards for low AC voltages. The Central Office of Measures (GUM) in Warsaw, Poland, like many other NMIs, uses TVCs as reference standards for AC voltages. More precisely, a set of single-junction Holt Model 11 TVCs is used as a reference standard for AC voltages above 600 mV, while a semiconductor multi-range Fluke 792A TVC serves as a highest level working standard for these voltages and as a reference standard for the AC voltages below 600 mV. The precise traceability chart for AC voltages is shown in Fig. 2. The AC voltage unit is transferred at GUM using the dual - channel method for TVC comparison. This method is discussed and schematic of the measurement system is shown in Fig. 5. The consecutive equation describing an AC-DC difference of the TVC is discussed (equations (3) and (4)). The full analysis of the uncertainty budget is performed following the JCGM guide recommendations. Finally, two practical examples of the experimental results are given. In the first example a Fluke 792A TVC calibration at 10 V AC and 1 kHz is analysed and the measurement uncertainty is calculated (Tab. 1). In the second example the calibration results obtained at GUM and at PTB are compared for the same Fluke 792A TVC at 600 mV and frequencies ranging from 10 Hz to 1 MHz (Fig. 6).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1281-1284
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ do pomiaru tłumienia napięcia współbieżnego precyzyjnych komparatorów napięcia typu LM111
Circuit for measuring of common mode rejection ratio of precise voltage comparators type LM111
Autorzy:
Wiśniewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/158333.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparatory napięcia
miernictwo układów scalonych
układy scalone
integrated circuits
measurement of integrated circuits
voltage comparators
Opis:
W pracy rozważono zagadnienie pomiaru, przy prądzie przemiennym i zamkniętej pętli sprzężenia zwrotnego, współczynnika tłumienia napięcia współbieżnego (CMRR) o wartości rzędu 1•105 ÷ 1•107 (tj. (100 ÷ 140) dB) scalonych komparatorów napięcia typu LM111. W wyniku przeprowadzonej analizy teoretycznej właściwości metrologicznych układu pomiarowego ustalono istotny związek między stosunkiem mierzonych w układzie napięć, zależnym od współczynnika CMRR, a innymi parametrami badanego komparatora napięcia, w tym zwłaszcza wzmocnieniem napięcia różnicowego, stanowiący podstawę ilościowej oceny błędu metody pomiarowej. Zaproponowano nowe techniczne rozwiązanie układu pomiarowego zawierające specjalny transformator pomiarowy napięcia przemiennego wyposażony we wtórne uzwojenia o nawoju bifilarnym, co przyczyniło się do wyeliminowania wpływu skończonej wartości wzmocnienia różnicowego badanego komparatora napięcia na mierzoną wartość współczynnika CMRR.
The comparator open-loop common-mode rejection ratio (CMRR) is a measure of the comparator's ability to reject common signals present in equal measure at both inputs. CMRR according to the definition is the ratio of the differential-mode gain to common-mode gain. Often, manufacturer data sheets only give DC CMRR value and CMRR curve over frequency while no measurement methods are given. The present work deals with measurements of common mode rejection ratio of values of the order 1•105 ÷ 1•107 (i.e. (100 ÷ 140) dB) of the voltage comparators type LM111. The present investigation concerns the method of measurement of coefficient CMRR with closed loop feedback of voltage comparator at alternating current. Important relationship between measured output voltage (Uwy) and finite values of parameters of comparator and others parameters of measuring circuit has been discovered by means of detailed analysis (see equations (12) and (17)). This relationship is the basis for quantitative analysis of the error of measuring method. Finally proposed - by author - a new solution of measuring circuit different from others existing up to date offer significant improvements over previous methods and is capable of accurate measurements on high-performance analogue comparators. It is based on special precise inductive voltage transformer with bifilar windings (Tr, Fig. 4). Such the error of measuring method is independent from finite value of differential open loop voltage gain and the output voltage is directly related to CMRR. The unity gain differential amplifier (buffer) which is implemented at input device under test (DUT: KB, Fig. 2÷4) eliminates differential and common-mode input resistances of DUT on measuring output voltage and thereby CMRR.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 10, 10; 1238-1242
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary napięcia zasilania stojana silnika w napędzie falownikowym
Measurements of stator voltage in the inverter-fed drive system
Autorzy:
Zawarczyński, Ł.
Stefański, T.
Powiązania:
https://bibliotekanauki.pl/articles/314146.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
napęd falownikowy
stojan silnika
napięcie fazowe
napięcie międzyfazowe
pomiar wartości chwilowej
inverter-fed drive system
motor stator
phase voltage
interphase voltage
measurement of temporary values
Opis:
W artykule przedstawiono analizę układów pomiarowych napięć stojana silnika zasilanego z falownika napięcia. Badania eksperymentalne układów pomiarowych przeprowadzono pod kątem oceny ich pasma przenoszenia, właściwości dynamicznych i dokładności pomiaru. Przedstawiono metody pomiaru wartości chwilowych napięć fazowych i międzyprzewodowych. Testy eksperymentalne przeprowadzono na stanowisku badawczym napędu falownikowego z silnikiem asynchronicznym o mocy 2,6 kW.
This paper presents an analysis of the measuring systems of the stator voltage of inverter-fed motor drive system. Experimental tests of measurement systems were carried out to calculate their bandwidth, dynamic properties and accuracy. The methods of measuring the temporary values of the phase voltages and interphase voltages. Experimental tests were carried out on the inverter-fed drive system with asynchronous motor with a power of 2,6 kW.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1514-1518
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroprocesorowy miernik impedancji pętli zwarciowej eliminujący wpływ odkształcenia napięcia przez regulację argumentu obciążenia pomiarowego
Microprocessor fault loop impedance meter eliminating the influence of voltage distortion by adjusting the load impedance argument
Autorzy:
Roskosz, R.
Świsulski, D.
Powiązania:
https://bibliotekanauki.pl/articles/155959.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fault loop impedance
measurement
distorted voltage waveform
electrical shock protection
impedancja pętli zwarciowej
pomiary
napięcie odkształcone
ochrona przeciwporażeniowa
Opis:
W artykule przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach o napięciu odkształconym. Zaproponowano metodę pomiaru impedancji pętli eliminującą wpływ odkształcenia napięcia i zbudowano mikroprocesorowy miernik, który ją wykorzystuje. W mierniku zastosowano impedancyjne obciążenie pomiarowe o stałej wartości modułu i regulowanym automatycznie argumencie. Przy zrównaniu argumentu impedancji obciążenia pomiarowego do wartości argumentu impedancji pętli, w pełni eliminuje się wpływ wszystkich harmonicznych występujących w krzywej napięcia sieci, a wynik pomiaru zależy od największej różnicy wartości skutecznych mierzonych napięć.
The paper presents the problem of measuring the fault loop impedance in networks with a distorted voltage waveform. When testing effectiveness of a protective earthing system, it is necessary to know the measured value of the fault loop impedance. An accurate loop impedance measurement is needed for reliable operation of protective devices and, consequently, for the safety of human beings and apparatus. The measurement accuracy depends on the parameters of the tested circuit, the disturbances within the supplying system, and the measuring method and instrument used. Most present-day techniques for measurement of the fault loop impedance are based on determination of the voltage drop across the loop impedance when a known value measuring load impedance is switched ON and OFF between the conductors being tested. The loop impedance meters and methods which are used today may cause a large error in the measured impedance value due to reactance in the tested network and the distortion of voltage waveform. The proposed method for measuring the loop impedance eliminates the influence of voltage distortion on the measurement result. In the loop impedance meter there is used the measuring load impedance of constant magnitude and the argument adjusted automatically in steps. When the argument of load impedance equals the argument of the loop impedance, the impact of all harmonics present in the voltage waveform is eliminated, and the measurement result depends on the greatest difference of RMS measured voltages. The construction and measuring procedure of the model microprocessor loop impedance meter are simple, and the measurement result is indicated directly in ohms.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 564-567
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instalacja energetyczna użytkowana w wybranym budynku : ocena wybranych parametrów technicznych
Analysis of electrical energy consumption on the example of a selected building
Autorzy:
Suproniuk, Marek
Paś, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/210858.pdf
Data publikacji:
2019
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
pomiar parametrów jakości energii elektrycznej
wyższe harmoniczne napięcia/prądu
electricity quality parameters measurement
higher harmonics of current/voltage
Opis:
W Polsce ok. 95% energii elektrycznej wytwarza się w procesie spalania węgla [6, 7]. Oszczędzanie energii elektrycznej daje wymierne efekty ekonomiczne związane z mniejszymi rachunkami, a także przyczynia się do ochrony środowiska naturalnego. Pochodną tego są oszczędności związane z naszym zdrowiem, mniejszą degradacją środowiska naturalnego, czy w efekcie oszczędności złóż energii. W artykule przedstawiono zagadnienia związane z analizą zużycia energii elektrycznej w wybranym obiekcie budowlanym. Uwzględniono dwa następujące zagadnienia - analizę dokumentów związanych z zasilaniem w energię elektryczną, rozdziałem energii, poborem mocy poszczególnych odbiorników i reżimami czasowymi pracy odbiorników w obiekcie oraz analizę odczytów analizatora energii elektrycznej zainstalowanego na obiekcie.
In Poland, approx. 95% of electrical energy is generated in a coal combustion process. Saving electrical energy gives economic effects related to the smaller fees and contributes to protection of the natural environment. Additionally, saving electrical energy should translate into our health, lesser degradation of the natural environment, or less consumption of natural deposits of energy. The paper has presented the issues related to analysis of energy consumption in a selected building object. The analyse includes the following issues - document analysis related to the building’s power, energy distribution, and power consumption of individual load and time regimes of work of receivers in the object and analysis of electrical energy which has been measured in a building.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2019, 68, 1; 165-174
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i przykładowe zastosowanie stanowiska pomiaru i rejestracji prądów i napięć w instalacjach trójfazowych
Design and sample application stand of measurement and registration currents and voltages in three-phase mains
Autorzy:
Uździcki, W.
Chciuk, M.
Bachman, P.
Aksentowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/276799.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiary
rejestracja
napięcie
prąd
moc
sieć trójfazowa
siła skrawania
measurement
recording
voltage
current
power
three-phase mains
cutting force
Opis:
W artykule opisane jest stanowisko do pomiarów i rejestracji podstawowych parametrów sieci trójfazowych. Opisano w nim budowę stanowiska pomiarowego a następnie zależności matematyczne dotyczące mierzonych sygnałów. W końcowej części artykułu przedstawiono wyniki przykładowych pomiarów.
This paper describes a stand to measure and record the basic parameters of the three-phase mains. Describes the construction of measuring stand and mathematical relations of the measured signals. Finally, the paper presents the results of the sample measurements.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 525-529
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie sztucznych sieci neuronowych do zmniejszenia błędów przetworników impedancji
Error correction of impedance-voltage converter with neural network application
Autorzy:
Wrzuszczak, M.
Khoma, Y.
Powiązania:
https://bibliotekanauki.pl/articles/266534.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przetwornik impedancja-napięcie
sztuczne sieci neuronowe
korekcja wyników pomiarów
impedance to voltage converter
artificial neural network
measurement error correction
Opis:
Przetworniki impedancja – napięcie (Z/U) stanowią podstawowy element komputerowych tomografów impedancyjnych. W artykule przedstawiono sposób zmniejszenia błędów przetwarzania przetwornika Z/U z zastosowaniem sztucznej sieci neuronowej wielowarstwowej, perceptronowej (MLP). Dokładność metody porównano z dokładnością uzyskaną w przypadku wyznaczania poprawek dla dwu składowych impedancji: rezystancyjnej i reaktancyjnej na podstawie wzorów analitycznych wyprowadzonych dla schematu zastępczego układu.
Impedance – voltage transducer (Z/U) are fundamental circuits in Impedance Tomography devices. In the paper the transducer error reducing method for resistance and reactance components of impedance with Multi-Layer Perceptron artificial neural network application is presented. The accuracy of the method is compared with the values calculated with analytical formulas derived for equivalent circuit of the transducer. The consideration presented in the paper focuses only on decreasing the processing error of the impedance/voltage transducer (Z/U), neglecting errors being introduced by following electronic processing stages i.e. phase detector and analog /digital converter.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 49; 133-136
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa metoda pomiaru impedancji pętli zwarciowej bez wyzwalania wyłączników różnicowoprądowych
A new method for measurement earth fault loop impedance without Tripping residua current devices
Autorzy:
Roskosz, R.
Wołoszyk, M.
Ziółko, M.
Jakubiuk, K.
Swedrowski, L.
Swisulski, D.
Powiązania:
https://bibliotekanauki.pl/articles/267343.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci niskiego napięcia
RCD
impedancja pętli zwarciowej
metody pomiarowe
pomiar impedancji bez wyzwalania RCD
low voltage network
earth fault loop impedance
measurement methods
measurement loop
impedance without tripping RCD
Opis:
W referacie przedstawiono problematykę pomiaru impedancji pętli zwarciowej w sieciach niskiego napięcia z wyłącznikami różnicowopradowymi (RCD - Residul Current Device). Zaproponowano nową metodę i układ do pomiaru impedancji pętli bez wyzwalania RCD. Pomiar nową metodą przeprowadzany jest przy stosowaniu dużej wartości pełnofalowego prądu pomiarowego, co wpływa korzystnie na dokładność pomiaru. Metoda ta umożliwia łatwe przystosowanie obecnie produkowanych przyrządów do pomiaru impedancji pętli zwarciowej w obwodach z RCD.
This paper presents the problem of earth fault loop impedance measurement in low voltage network with RCD – Residual Current Device. The proposed new method and system for measurement of loop impedance without tripping. RCD use high-value, fullcycles testing current, which has a positive effect on measurement accuracy. This method enables easy adaptation of currently manufactured of Loop Impedance Meters for use in circuits with RCD. The value of earth fault loop impedance is required to determine the effectiveness of protective systems against electric shock. Measurement of fault loop impedance in installations with RCD always create problems since the high testing current trips RCD. There are several techniques that are less liable to trip RCD, they have know disadvantages and have major drawbacks. One commonly use techniques is to bypass the RCD by shorting links. The second technique use d.c. current to saturate the core of the RCD prior to the test. Another method is to reduce testing current to or below 15mA, so RCDs having a rated residual current 30mA or greater will not trip. The new method for measurement loop impedance using high testing current Ip flowing in phase conductor of the tested circuit will not trip the RCD thanks to use the Current Transducer PPD, which provides the flow in neutral conductor of RCD the complementary current Id. The testing current Ip and complementary current Id are flowing in opposite direction through RCD, and have the same value (Ip = Id). In practice as a Complementary Current Transducer PPD can be used current transformer with a rated current ratio equal to one, and is located in housing of Loop Impedance Meter.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 34; 57-62
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of current-voltage converter with amorphous core
Działanie przetwornika prądowo-napięciowego z rdzeniem amorficznym
Autorzy:
Habrych, M.
Powiązania:
https://bibliotekanauki.pl/articles/1361018.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
amorphous material
current measurement
current-voltage converter
deformed current waveform
materiały amorficzne
pomiary prądu
przetwornik prądowo-napięciowy
zniekształcone przebiegi prądu
Opis:
The paper presents and discusses investigated results of metrological characteristics of a new generation of current-voltage converters manufactured with the use of the innovative technology of soft magnetic components. Current and angle errors of the converters together with current and frequency ranges of their work have been identified.
W artykule przedstawiono i omówiono wyniki badań charakterystyk metrologicznych nowej generacji przetworników prądowo-napięciowych wyprodukowanych przy użyciu innowacyjnej technologii miękkich części magnetycznych. Określono błędy prądowe i kątowe przetworników wraz z zakresami prądowymi i częstotliwościowymi ich pracy.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2016, 54, 1; 15-20
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wybranych właściwości sygnału wytwarzanego przez cyfrowe źródło wzorcowego napięcia przemiennego z interpolatorem pierwszego rzędu
Analysis of selected properties of the signal generated by a digital source of the standard AC voltage with a first-order interpolator
Autorzy:
Dudzik, K.
Kampik, M.
Powiązania:
https://bibliotekanauki.pl/articles/972211.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce napięcia przemiennego
źródła sygnałów pomiarowych
cyfrowa synteza sygnału
interpolacja
AC voltage standards
sources of measurement signals
digital signal synthesis
interpolation
Opis:
W artykule przedstawiono analizę właściwości sygnału generowanego przez cyfrowe źródło sinusoidalnego wzorcowego napięcia przemiennego wyposażone w interpolator pierwszego rzędu. Interpolator pierwszego rzędu pozwala na uzyskanie sygnału aproksymowanego odcinkowo w miejsce sygnału aproksymowanego sygnałem schodkowym. Głównym celem analizy było uzyskanie odpowiedzi na pytanie, czy zastosowanie interpolatora pierwszego rzędu rzeczywiście umożliwia zmniejszenie zawartości harmonicznych w widmie wytwarzanego przez źródło sygnału. Zaproponowano również przykładowe rozwiązania układowe analogowych i cyfrowych interpolatorów pierwszego rzędu.
The paper presents analysis of the signal generated by a digital source of the standard sinusoidal voltage. In the source the digital-to-analog converter (DAC) used for reconstruction of the sinusoidal waveform is followed with a first-order interpolator. The interpolator approximates a staircase waveform at the DAC output with piecewise approximation of the signal. It is shown in the paper that use of the first-order interpolator improves the spectral purity of the generated sine wave significantly and is especially beneficial for low number of samples per period of the generated sinusoidal waveform. The disadvantage of the source with the first-order interpolator is the need to use two digital-to-analog converters. Nonlinearities of both DACs may generate harmonics located close to the fundamental and difficult to be filtered out. Despite this drawback, the authors speculate that use of modern electronic components in the interpolator will increase the stability and accuracy of the signal produced by the source. The paper presents a few ideas of the circuits of analog and digital first-order interpolators. The presented analysis does not include the effect of finite resolution of digital-to-analog converters, their nonlinearity, the impact of analog circuits, and other phenomena.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 414-417
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorce jednostek miar rezystancji i napięcia elektrycznego a podstawowe stałe fizyczne
Voltage and resistance standards and basic physical constants
Autorzy:
Dudek, E.
Mosiądz, M.
Powiązania:
https://bibliotekanauki.pl/articles/151376.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce
rezystancja
napięcie elektryczne
zjawisko Josephsona
kwantowy efekt Halla
system miar
standard
resistance
voltage
Josephson effect
quantum Hall effect
measurement units system
Opis:
Współczesne kierunki rozwoju metrologii postulują odejęcie od tradycyjnych materialnych wzorców jednostek miar i zastąpienie ich wzorcami opartymi na zjawiskach kwantowych. Referat przedstawia fizyczne podstawy najnowocześniejszych wzorców napięcia elektrycznego (opartego na zjawisku Josephsona) i rezystancji (kwantowy efekt Halla), systemy odtwarzania jednostek miar pracujące w oparciu o nie, a także korzyści płynące z włączenia ich do polskiego systemu miar.
Modern metrology postulates replacing material standards with quantum standards. Article describes physical phenomenas and working principles of voltage (Josephson effect) and resistance (quantum Hall effect) standards, measurement systems and advantages of using them in polish units system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 82-85
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wyższych harmonicznych napięcia zasilającego na rozkład temperatury silnika synchronicznego z magnesami trwałymi
Influence of voltage harmonic distortion on temperature distribution in line-start permanent magnet synchronous motor
Autorzy:
Lipiński, S.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/303913.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Druk-Art
Tematy:
silniki synchroniczne
magnesy trwałe
rozruch bezpośredni
analiza numeryczna
odkształcenie napięcia
pomiar temperatury
synchronous motors
permanent magnets
line start
voltage distortion
numerical analysis
temperature measurement
Opis:
Silniki synchroniczne wzbudzane magnesami trwałymi o rozruchu bezpośrednim (LSPMSM) są wysoko sprawną alternatywą dla silników indukcyjnych. Wobec tego muszą one być projektowane z uwzględnieniem podobnych narażeń jak maszyny asynchroniczne. Jednym z takich narażeń jest praca przy zasilaniu napięciem odkształconym zawierającym wyższe harmoniczne. Dotychczasowe prace dotyczące wpływu odkształceń napięcia zasilającego na silniki indukcyjne pokazują, że prowadzą one do wzrostu strat i temperatur w maszynie. Ze względu na podobną konstrukcję, analogiczne zjawiska występują także w silnikach synchronicznych wzbudzanych magnesami trwałymi o rozruchu bezpośrednim. Na podstawie normy IEC 61000-2-2:2002 i IEC 61000-2-4:2002 zaprezentowano wpływ wyższych harmonicznych w napięciu zasilającym na temperaturę pracy silnika LSPMSM o mocy 1900 W oraz napięciu 400 V. Rozpatrywano przy tym pracę ustaloną silnika poddanego stałemu obciążeniu i wykorzystano model numeryczny sprzęgający dwukierunkowo pole elektromagnetyczne i cieplne.
Line-Start Permanent Magnet Synchronous Motors (LSPMSM) are high-efficient substitute for induction motors. Therefore they have to designed regarding the same exposures like asynchronous motors. One of such exposal is operation with distorted power supply voltage. Foregoing papers concerning influence of the voltage distortion on induction motors show that higher harmonics lead to increased temperature of the machine. Because of similar construction such phenomenon occurs also in LSPMSM. According to standards IEC 61000-2-2:2002 and IEC 61000-2-4:2002 presented influence of harmonics in power supply voltage during steady state operation with constant load equal to 1900 W and fed with voltage 400 V. Two-way coupled electromagnetic and thermal model was used in numerical analysis.
Źródło:
Napędy i Sterowanie; 2017, 19, 10; 102-107
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda zmniejszenia wartości błędu uśredniania w systemie pomiarowym wykorzystującym przetwornik "napięcie-częstotliwość"
A method for decreasing the average error in a measurement system using a "voltage-to-frequency" converter
Autorzy:
Warda, P.
Powiązania:
https://bibliotekanauki.pl/articles/155829.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetwornik napięcie-częstotliwość
pomiar częstotliwości
tor z częstotliwościowym nośnikiem informacji
voltage-to-frequency converter
frequency measurement
slotted line with a frequency carrier of information
Opis:
Przetwarzanie zmiennego napięcia w przetworniku typu "napięcie-częstotliwość" powoduje wygenerowanie sygnału wyjściowego o zmiennej częstotliwości. Istotnym składnikiem wypadkowego błędu przetwarzania informacji o wejściowym, zmiennym napięciu jest błąd uśredniania, którego wartość rośnie wraz ze zmniejszaniem częstotliwości wyjściowej przetwornika. W pracy opisano metodę pozwalającą na zmniejszenie błędu uśredniania poprzez zadawanie dodatkowego napięcia korygującego.
The paper presents a new method decreasing the total error in a slotted line with a frequency carrier of information. A changeable voltage conversion in a "frequency-to-voltage" converter causes generation of a signal of changeable frequency. In the presented situation the essential component of the total conversion error is the average error. When the frequency of a "voltage-to-frequency" converter output signal is decreased, the average error rises. The paper describes the method which allows decreasing the average error by setting the additional correcting voltage. Recent research on decreasing the conversion error in a slotted line are presented in the paper. Influence of the error components on conversion is also discussed (Fig. 1). There has been obtained the formula describing how a quotient of the constant component to the frequency signal amplitude influence the total error (1). A schematic diagram of a system for correction of the constant component is shown in Fig.3. There is also given the analysis of influence of the constant component on the total error (Fig. 5). The procedure for correction of the constant component is described and the procedure algorithm is given.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1297-1300
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ odkształceń napięcia w sieci zasilającej na rozkład temperatury silnika synchronicznego wzbudzonego magnesami trwałymi
Influence of voltage distortion on temperature distribution in line-start permanent magnet synchronous motor
Autorzy:
Lipiński, Sz.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1199647.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki synchroniczne
magnesy trwałe
rozruch bezpośredni
analiza numeryczna
odkształcenie
napięcia
pomiar temperatury
synchronous motors
permanent magnets
line start
voltage distortion
numerical analysis
temperature measurement
Opis:
Line-Start Permanent Magnet Synchronous Motors (LSPMSM) are increasingly used in preference to induction motors. Therefore they have to be resistant to the same exposures like asynchronous motors. One of such exposal is operation with distorted power supply voltage. Foregoing papers concerning influence of the voltage distortion on induction motors show that higher harmonics lead to increased temperature of the machine. By virtue of similarity in construction such phenomenon occurs also in LSPMSM. According to standards IEC 61000-2-2:2002 and IEC 61000-2-4:2002 presented influence of harmonics in power supply voltage during steady state operation with constant load. Two-way coupled electromagnetic and thermal model was utilized in numerical analysis.
Silniki synchroniczne wzbudzane magnesami trwałymi o rozruchu bezpośrednim są coraz częściej stosowane w miejsce silników indukcyjnych. Wobec tego muszą być odporne na podobne narażenia jak maszyny asynchroniczne. Jednym z takich narażeń jest praca przy zasilaniu napięciem odkształconym. Dotychczasowe prace dotyczące wpływu odkształceń napięcia zasilającego na silniki indukcyjne pokazują, że wyższe harmoniczne powodują wzrost temperatur w maszynie. Ze względu na zbliżoną konstrukcję, podobne zjawiska występują także w silnikach synchronicznych wzbudzanych magnesami trwałymi o rozruchu bezpośrednim. Na podstawie normy IEC 61000-2-2:2002 i IEC 61000-2-4:2002 zaprezentowano wpływ wyższych harmonicznych w napięciu zasilającym na temperaturę pracy silnika tego typu o mocy 1900 W oraz napięciu 400 V. Rozpatrywano przy tym pracę ustaloną silnika ze stałym obciążeniem i do obliczeń wykorzystano model numeryczny sprzęgający dwukierunkowo pole elektromagnetyczne i cieplne.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 1, 113; 117-122
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zależność częstotliwościowa napięciowego współczynnika magnetoelektrycznego w ceramikach (BiFeO3)x-(BaTiO3)1-x
Частотна залежність магнітоелектричного коефіцієнту напруги у кераміці (BiFeO3)X-(BaTiO3)1-X
Frequency dependence of the magnetoelectric voltage coefficient in (BiFeO3)x-(BaTiO3)1-x ceramics
Autorzy:
Pikula, T.
Kowal, K.
Guzdek, P.
Powiązania:
https://bibliotekanauki.pl/articles/407817.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
multiferroiki
efekt magnetoelektryczny (ME)
materiały magnetoelektryczne
napięciowy współczynnik magnetoelektryczny
dynamiczna metoda pomiaru
multiferroics
magnetoelectric effect (ME)
magnetoelectric materials
magnetoelectric voltage coefficient
lock-in technique
dynamic measurement of ME effect
Opis:
Zależność właściwości magnetoelektrycznych od składu chemicznego w ceramikach (BiFeO3)x-(BaTiO3)1-x została w ostatnim czasie zaobserwowana i odnotowana w literaturze. Pomiary efektu magnetoelektrycznego (ME) w tych materiałach wykonywane były metodą dynamiczną. Próbki o x = 0,9, 0,8 i 0,7 umieszczano w stałym (DC) polu magnetycznym generowanym przez elektromagnes, na które nałożono zmienne (AC) pole magnetyczne o częstotliwości f = 1kHz wytwarzane przez cewki Helmholtza. W niniejszej pracy przedstawiono podstawy teoretyczne tego rodzaju pomiarów oraz wyznaczono optymalną częstotliwość pola AC, która minimalizuje procesy powodujące redukcję mierzonego sygnału napięciowego.
Залежність магнітоелектричних властивостей від хімічного складу кераміки (BiFeO3)x-(BaTiO3)1-x цей факт був досліджений нещодавно і занотований в літературі. Вимірювання магнітоелектричного ефекту (ME) в цих матеріалах були виконані за допомогою динамічною методу. Зразки o x = 0,9, 0,8 i 0,7 розміщені в магнітному полі постійного струму (DC), що генерується електромагнітом, на який накладено змінне (AC) магнітне поле з частотою f = 1 кГц, утворюване катушками Гельмгольца. В цій статті показана теоретична основа цього виду вимірювання та визначена оптимальна частота поля АС, яка мінімалізує процеси, які зменшують вимірюваний сигнал напруги.
Composition-dependent magnetoelectric properties of sintered (BiFeO3)x-(BaTiO3)1-x ceramics have been recently observed and reported in the literature. Measurements of the magnetoelectric effect (ME) for these materials have been performed by usage of the dynamic method. The samples with x = 0.9, 0.8 and 0.7 were placed in a static (DC) magnetic field created by an electromagnet on which a sinusoidal (AC) magnetic field with a frequency of 1 kHz produced by Helmholtz coils was superimposed. In this work the theory of the dynamic measurement was presented and the optimal frequency of the AC field was determined in order to minimize the processes causing undesired reduction of the measured voltage signal.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 4; 62-69
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-31 z 31

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies