Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "ventilation" wg kryterium: Temat


Tytuł:
The influence of alternative characteristics of the vicinity of the ventilation district on air quantity
Autorzy:
Pach, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/220241.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalni
rejon wentylacji
zagrożenie wentylacyjne
mine ventilation network
ventilation district
alternative characteristics
ventilation hazards
Opis:
Subnetwork with two nodes shared with entire ventilation network can be separated as its part. For the network under common ventilation conditions, one of these nodes will become the subnetwork starting node, while the other will be the subnetwork end node. According to the graphs theory, such a piece of the network can be considered as a subgraph of the graph representing the entire ventilation network. A special feature of that subgraph is lack of predecessors of the subnetwork starting node and lack of successors of the subnetwork end node. Ventilation district of a mine may be often treated as a subnetwork. Vicinity is a part of the network which is not separated as subnetwork. In the case of a ventilation district its vicinity forces air flow through the district. The alternative characteristic curve of the vicinity can therefore be compared to the characteristics curve of a fictional fan that forces the airflow in the district. The alternative characteristics (later in the text: the characteristics) of the vicinity of the ventilation district in an underground mine strongly influence air quantity and therefore play a crucial role in the reduction of methane, fire and thermal hazards. The role of these characteristics and proper selection of their approximating function were presented in the article. The reduction of resistance of an intake stopping (having influence on entire resistance of a ventilation district) produces increased airflow in the district. This changes of airflow in the district caused by a variation in internal resistance (e.g. by opening an internal regulation stopping) depends on the characteristic of the vicinity of the district. Proper selection of its approximating function is also important for this matter. The methods of determination of the alternative characteristic curve of the district vicinity are presented. From these procedures it was possible to obtain the results of air quantities and differences in isentropic potentials between an inlet and an outlet to/from the ventilation district. Following this, the characteristics were determined by graphic and analytic methods. It was proved that, in contrast to flat vicinity characteristics, steep ones have a smaller influence on the airflow modification in the district (which are caused by a regulation of the district resistance). The characteristic curve of the vicinity determines the ability to regulate air quantity and velocity in the district.
Źródło:
Archives of Mining Sciences; 2020, 65, 1; 47-58
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of automated mine ventilation control systems for Belarusian potash mines
Autorzy:
Semin, Mikhail A.
Levin, Lev Y.
Maltsev, Stanislav V.
Powiązania:
https://bibliotekanauki.pl/articles/1853845.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wentylacja kopalni
wentylator
automatyczne sterowanie wentylacją
mine ventilation
ventilation on demand
automated ventilation control
energy efficiency
main fan
ventilation door
potash mines
Opis:
In recent decades, two different approaches to mine ventilation control have been developed: ventilation on demand (VOD) and automatic ventilation control (AVC) systems. The latter was primarily developed in Russia and the CIS countries. This paper presents a comparative analysis of these two approaches; it was concluded that the approaches have much in common. The only significant difference between them is the optimal control algorithm used in automatic ventilation control systems. The paper describes in greater detail the algorithm for optimal control of ventilation devices that was developed at the scientific school of the Perm Mining Institute with the direct participation of the authors. One feature of the algo-rithm is that the search for optimal airflow distribution in the mine is performed by the system in a fully automated mode. The algorithm does not require information about the actual topology of the mine and target airflows for the fans. It can be easily programmed into microcontrollers of main fans and ventilation doors. Based on this algorithm, an automated ventilation control system was developed, which minimizes energy consumption through three strategies: automated search for optimal air distribution, dynamic air distribution control depending on the type of shift, and controlled air recirculation systems. Two examples of the implementation of an automated ventilation control system in potash mines in Belarus are presented. A significant reduction in the energy consumption for main fans’ operation obtained for both potash mines.
Źródło:
Archives of Mining Sciences; 2020, 65, 4; 803-820
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uproszczona analiza działania wentylacji grawitacyjnej w sezonie ogrzewczym na przykładzie danych meteorologicznych Warszawy
Simplified analysis of the operation of gravity ventilation in the heating season on the example of meteorological data for Warsaw
Autorzy:
Jędrzejuk, H.
Powiązania:
https://bibliotekanauki.pl/articles/270505.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
energetyka
wentylacja
wentylacja grawitacyjna
energy
ventilation
gravity ventilation
Opis:
W artykule sprawdzono wpływ zmienności temperatury powietrza zewnętrznego i wielkości kanałów wentylacyjnych na zmienność intensywności wymiany powietrza w budynkach z wentylacją grawitacyjną w sezonie ogrzewczym. Wyznaczono również średnią wartość strumienia powietrza w tym okresie. Przedstawiono metodę wymiarowania kominów wentylacyjnych, która jest zgodna z wymaganiami Rozporządzenia Ministra Infrastruktury [13] (według normy PN-B-03430:1983/Az3:2000 [5]). Następnie przeprowadzono obliczenia, w których dodatkowo uwzględniono wilgotność względną powietrza wewnętrznego i zewnętrznego.
This article examines the influence of outdoor air temperature variations and the size of ventilation ducts on the variation of air exchange intensity in buildings with gravitational ventilation during the heating season. The mean value of the air flow was also determined during this period. The method of dimensioning ventilation chimneys, which complies with the requirements of the Regulation of the Minister of Infrastructure (according to PN-B-03430:1983/Az3:2000). Subsequent calculations were made in which the relative humidity of the internal and external air was also taken into account.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 4; 260-268
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sposób doprowadzenia powietrza kompensacyjnego a wzdłużna wentylacja pożarowa stacji metra
The Influence of Air Supply Methods on Longitudinal Fire Ventilation of Underground Stations
Autorzy:
Krajewski, G.
Węgrzyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/372886.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
wentylacja pożarowa
wentylacja tuneli
wentylacja wzdłużna
metro
kompensacja
fire ventilation
tunnel ventilation
longitudinal ventilation
underground railway
air supply
Opis:
Cel: Przedstawienie wyników badań własnych autorów w obszarze systemów wentylacji podziemnych obiektów kolejowych na przykładzie sieci metra. Badania obejmowały przede wszystkim powiązanie wpływu sposobu doprowadzenia powietrza kompensacyjnego do obszaru stacji metra ze skutecznością działania systemu wzdłużnej wentylacji tej stacji. Artykuł ma na celu zapoznanie projektantów z możliwym zastosowaniem wentylacji wzdłużnej, także w obszarze stacji podziemnych, poprzez podkreślenie wad i zalet tego rozwiązania. Artykuł zredagowano na podstawie wyników badań prezentowanych na konferencji „Budownictwo podziemne i bezpieczeństwo w komunikacji drogowej i infrastrukturze miejskiej” (Kraków 2016). Wprowadzenie: Jednym z dopuszczonych do stosowania rozwiązań wentylacji pożarowej podziemnych stacji kolei (metra) jest system wentylacji wzdłużnej, bazujący na rozwiązaniach podobnych do tych wykorzystywanych w wentylacji tuneli. Systemy wentylacji wzdłużnej mogą zapewnić podobne warunki środowiska do systemów poprzecznych (oddymiania). Chronią one cały obszar stacji i zapewniają drogę wejścia dla ekip ratowniczo-gaśniczych. Aby spełniały te funkcje, należy poprawnie dobrać metodę doprowadzenia powietrza kompensacyjnego do obszaru stacji, zarówno w sposób mechaniczny, jak i naturalny. Duże znaczenie ma również stosunek ilości powietrza doprowadzanego w sposób mechaniczny oraz grawitacyjny. W artykule autorzy prezentują wyniki przeprowadzonego krótkiego programu badań numerycznych, w ramach którego analizowano wpływ bilansu powietrza doprowadzanego na efekty działania systemu wentylacji pożarowej peronów. Metodologia: W pracy przedstawiono w głównej mierze wyniki badań własnych autorów, wykonanych z wykorzystaniem metody obliczeniowej mechaniki płynów (CFD), które osadzono w kontekście literaturowym tematu. Dodatkowo zaprezentowano własne doświadczenia zdobyte w trakcie kilkuset testów z gorącym dymem w trakcie odbiorów II linii Metra Warszawskiego. Wnioski: Systemy wentylacji pożarowej wzdłużnej są w stanie zapewnić porównywalne warunki środowiska w obrębie tuneli i stacji metra do systemów poprzecznych. Działanie systemu wzdłużnego można uznać za bezpieczniejsze z punktu widzenia ratowników prowadzących działania ratowniczo-gaśnicze. Kluczową rolę w określeniu skuteczności systemu mają sposób dostarczania powietrza oraz ilość powietrza, które dostarczane jest mechanicznie.
Aim: The purpose of this paper is to reveal the outcome from studies performed by the authors about smoke and heat ventilation systems for underground railway buildings using an underground railway network as an example. Research activity examined, in particular, the link between air supply methods to an underground station area with the effective performance of a longitudinal ventilation system at such a station. The intention for this publication is to increase the design credibility for longitudinal ventilation solutions, including solutions for underground stations, by highlighting associated advantages and disadvantages. This article is based on experimental study results, which were presented at an international conference “Underground Buildings and Road Safety, and the Urban Infrastructure” (Budownictwo podziemne i bezpieczeństwo w komunikacji drogowej i infrastrukturze miejskiej), Kraków 2016. Introduction: Longitudinal ventilation systems provide one of the approved solutions for underground railway stations and are based on similar solutions applied in the ventilation of road tunnels. Such system may provide similar environmental conditions as with transverse systems, at the same time preserve areas throughout the station from smoke and ensure safe access for firefighting and rescue teams. In order to achieve this, a key issue, which must be addressed, concerns the choice of supply strategy for the delivery of air to the underground location. This may be by mechanical as well as natural means. Likewise, the volume relationship between air supplied by mechanical and gravitational means has a crucial impact on the performance of the ventilation system. The authors reveal results from a short programme of numerical studies, which analysed the air flow relationship to achieve an optimum balance, and the consequential performance of fire ventilation systems on station platforms. Methodology: The study reveals results from original research performed by the authors, which is based on the literature review in this area, using the Computational Fluid Dynamics method (CFD), Additionally, numerical study results are supported by the authors personal experience acquired through numerous hot smoke tests performed during the commissioning phase of the Warsaw Metro, Line 2. Conclusions: Longitudinal systems can provide similar environmental conditions as traditional transverse systems. During firefighting and rescue operations, longitudinal systems provide more safety for firefighters than transverse solutions. The key role in the system performance can be attributed to the supply method and volume of air provided by mechanical means.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 43, 3; 231-241
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka wewnętrznych instalacji wentylacyjnych w budynku Wydziału Budownictwa i Inżynierii Środowiska Politechniki Białostockiej po termomodernizacji
Characteristics of the inner ventilation system in the modernised building of the Faculty of Civil and Environmental Engineering of the Bialystok University of Technology
Autorzy:
Gładyszewska-Fiedoruk, K.
Powiązania:
https://bibliotekanauki.pl/articles/402982.pdf
Data publikacji:
2015
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
termomodernizacja
wentylacja
thermomodernization
ventilation
Opis:
W artykule przedstawiono stan techniczny instalacji wentylacyjnej w budynku Wydziału Budownictwa i Inżynierii Środowiska Politechniki Białostockiej po termomodernizacji. W związku z przeprowadzoną kompleksową termomodernizacją omówiono zmiany, jakie zostały przeprowadzone w trakcie modernizacji systemu wentylacyjnego. Opisane przedsięwzięcia spowodowały podwyższenie sprawności systemów wentylacyjnych, a tym samym obniżenie zużycia energii i kosztów eksploatacyjnych.
The paper presents the technical condition of the ventilation system in the building of the Faculty of Civil and Environmental Engineering of the Bialystok University of Technology after its modernization. In connection with conducted comprehensive thermo-modernisation the changes that had been carried out during the ventilation system modernization were discussed. The described project increased the efficiency of ventilation systems and thereby reduction of energy consumption and operating costs.
Źródło:
Budownictwo i Inżynieria Środowiska; 2015, 6, 4; 155-159
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spontaneous Pneumoperitoneum in a Patient After Ventilation Therapy
Autorzy:
Marian, Kuczia
Monika, Kurowska
Bartosz, Kubica
Powiązania:
https://bibliotekanauki.pl/articles/1396000.pdf
Data publikacji:
2015-03-01
Wydawca:
Index Copernicus International
Tematy:
spontaneous pneumoperitoneum
ventilation therapy
Opis:
Free gas in the peritoneal cavity is not always associated with gastrointestinal perforation. The study presented a case of a 72-year old male patient with peritoneal emphysema, which developed after ventilation therapy. Suspecting gastrointestinal perforation the patient was subjected to laparotomy, which did not show perforation. The patient was diagnosed with spontaneous pneumoperitoneum. The patient died, due to cardiopulmonary and neurological disturbances. Withdrawal from non-therapeutic laparotomy may prove crucial in similar cases.
Źródło:
Polish Journal of Surgery; 2014, 86, 12; 601-603
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Solution to Ensure Ventilation when Expanding the Area of Cam Thanh Underground Coal Mine, Ha Long Coal Company, Vietnam
Autorzy:
Nguyen, Cao Khai
Nguyen, Van Tinh
Nguyen, Phi Hung
Nguyen, Van Quang
Powiązania:
https://bibliotekanauki.pl/articles/2020950.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
mine ventilation
mine ventilation and safety
Cam Thanh mines area
ventilation system adjustment
fan operating points
kopalnie
wentylacja
Wietnam
Opis:
In the process of underground mining, the mining system changes for various reasons. One of the main reasons is changes in the mining production plans, especially the scales and outputs. Nowadays, coal mines in Vietnam have been expanding in width and depth, and so have the mines’ ventilation systems. Consequently, there will be changes in the alteration of the structure of the design ventilation system, which reduces the effectiveness of the ventilation and does not meet the main objective of mine ventilation, directly affect the safety of the working environment in the mine. Therefore, it is necessary to research the improvement of the ventilation system with the development and specific conditions of underground coal mines in Vietnam, improving the efficiency of the ventilation work and assuring the safety of the mine environment. Cam Thanh coal mine, Ha Long coal company, Vietnam, is the case study for this research. The article considers the plan of increases the mining output by more than 1.5 times, propose solutions to improve the ventilation system accordingly, helping the company proactively implement the production plan, ensure the working environment's safety, and reduce the costs of mine ventilation.
Źródło:
Inżynieria Mineralna; 2021, 2; 533--542
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ elementów wspomagajacych wentylację grawitacyjną na warunki mikroklimatu
Autorzy:
Telejko, M.
Piotrowski, J.Z.
Powiązania:
https://bibliotekanauki.pl/articles/362344.pdf
Data publikacji:
2005
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
microclimate
gravitational ventilation
Opis:
Zastosowanie szczelnej obudowy budynków oraz szczelnej stolarki podyktowane względami ekonomicznymi spowodowało konieczność zastosowania nawiewników powietrza oraz nasad kominowych jako elementu uzupełnienia systemu wentylacji grawitacyjnej. Pomimo zastosowania tych rozwiązań w dalszym ciągu zauważa się jednak pewne nieprawidłowości w działaniu systemu wentylacji. W artykule przedstawiono wyniki badań przeprowadzonych na obiektach mieszkalnych wybudowanych w ciągu ostatnich pięciu lat i wyposażonych w szczelna stolarkę okienną, nawiewniki powietrza oraz nasady kominowe.
Applying tight concrete lining due to energetistic factors, as well as applying tight window joinery caused the necessity of using air intakes and passive or effective venilation assistance. They are used as the supplement to the system of ventilation in flats. In spite of such a solution, there occure some serious problem s in functioning of the ventilation. Results of the studies presented in the article concem alI the chosen flats which were built in the las t five years. The flats were equipped with the tight window joinery , air intakes and passive or effective ventilation assistance.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2005, T. 1; 331-337
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność urządzeń wentylacji miejscowej wywiewnej
The effectiveness of local exhaust systems
Autorzy:
Gliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/179514.pdf
Data publikacji:
2003
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
wentylacja
urządzenia wentylacyjne
pyły
emisja pyłów
ventilation
ventilation device
dusts
dust emission
Opis:
Autor przedstawił stan przedsięwzięć normalizacyjnych w zakresie oceny parametrów związanych z emisją zanieczyszczeń z maszyn i urządzeń oraz skuteczności działania odciągów wentylacyjnych. Omówił dotychczas stosowane metody badań w omawianym zakresie, wykonywanych w Niemczech i w Polsce. Przedstawił wyniki pomiarów emisji pyłu powstającego przy obróbce skrawaniem za pomocą ręcznych zmechanizowanych narzędzi i szlifierki stołowej oraz wyniki badań skuteczności odsysania pyłów przez wentylację miejscową wywiewną.
Current standardisation efforts in the field of evaluating parameters connected with the emission of airborne pollutants from machinery and devices end assessing the effectiveness of exhausts are presented. The article discusses methods used so far in Germany and Poland. The results of measurements of the emission of dust generated during machining using hand-held power tools end a bench grinder as well as results of testing the effectiveness of dust removal by local exhaust systems are presented.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2003, 6; 24-28
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smoke extraction garages
Autorzy:
Gładyszewska-Fiedoruk, Katarzyna
Milius, Povilas
Powiązania:
https://bibliotekanauki.pl/chapters/31020000.pdf
Data publikacji:
2019
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
ventilation system
garages
fire ventilation systems
legal requirements
smoke
smoke extraction system
Opis:
The dynamic development of motorization causes inadequate parking places in the city centers as well as in their outskirts. The emergence of new residential buildings and public utilities results in the need to create new parking spaces. Due to the problem of limited development space as well as the high cost of building plots, investors decide to create one or multi-storey closed garages. The area of these garages often reaches several tens of thousands of square meters. For these new parking spaces, an adequate and effective ventilation system should be provided, which at the same time functions as a residential ventilation system, and has a fire ventilation function as a means of protecting escape routes and rescue teams during a fire.
Źródło:
Buildings 2020+. Constructions, materials and installations; 227-246
9788365596703
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies