Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment system" wg kryterium: Temat


Tytuł:
Analysis and Assesment of the Wastewater Treatment Plant Operation in the City of Kłodzko
Autorzy:
Garbowski, T.
Wiśniewski, J.
Bawiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/125373.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment system
sewage treatment efficiency
WWTP
treatment plant reliability factor
Opis:
In this study, the current operation efficiency of the wastewater treatment plant (WWTP) in the city of Kłodzko in the Lower Silesia Voivodeship (Poland) was analyzed and the predicted amount of the wastewater flowing to the WWTP in a 20-year period (until the year 2036) was estimated. The data on the quality and the quantity of raw (entering to the WWTP) and treated sewage from the years 2012-2016 were analyzed. The five essential pollutants indicators: biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), total suspended solids (TSS), total nitrogen and total phosphorus, regulated in the water permit were used to evaluate the efficiency of contaminants removal. On the basis of the percentage reduction of the individual pollutants indicators and their acceptable concentrations in the treated sewage, the effectiveness of the operation of the object was determined. Furthermore, a so-called the treatment plant reliability factor (RF) was calculated and its value below 1.0 indicates the correct operation of the wastewater treatment plant. After determining the prospective amount of raw sewage in 2036 (based on the decreasing population in the city) it has been found that the WWTP will work with a significant reserve of capacity and the modernization of the treatment system, leading to a decrease of its capacity should be considered.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 114-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of Hydrophytes for Additional Treatmnet of Municipal Sewage
Autorzy:
Pichura, Vitalii
Potravka, Larisa
Ushkarenko, Viktor
Chaban, Viktor
Mynkin, Mykola
Powiązania:
https://bibliotekanauki.pl/articles/2086397.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water quality
sewage
treatment system
Eichhornia crassipes
Lemna minor
pollutant
water treatment
Opis:
At the current stage of discharge and treatment of municipal sewage and other types of wastewater in the territory of Ukraine, traditional technologies of biological treatment in aero-tanks by the process of aerobic oxidation involving active silt characterized by low efficiency are largely used. It was established that biological treatment and additional treatment of sewage involving hydrophytes are efficient. The research on wastewater quality and the efficiency of sewage treatment was conducted in three phases: Phase 1 – “the quality before treatment”, Phase 2 – “the quality after mechanical-biological treatment” at the existing municipal treatment plants, Phase 3 – “the quality after additional treatment by hydrophytes”. In order to determine the efficiency of using hydrophytes additional treatment, Eichhornia crassipes (water hyacinth) and the perennial aquatic plant Lemna minor were planted in one treatment pond. The results of the experiment made it possible to determine high efficiency of using hydrophytes for additional sewage treatment. In particular, the efficiency of additional treatment in the treatment ponds removing the residue of suspended pollutants for 40 days was 32%, toxic salts – 13.0–23.0%, oil products – 30.0%, biogenic substances – 68.5–83.3%. It caused a drop in the values of chemical and biological oxygen demand for 5 days by 89.6% and 61.2%, respectively. The efficiency of sewage treatment removing toxic salts and oil products reached 97.7%, whereas in the case of mineral and organic pollutants – up to 99%. That contributed to a considerable increase in the wastewater quality by the criteria for fisheries. In particular, high nutritional value of Eichhornia crassipes and Lemna minor allowed obtaining 12.5 tons of hydrophyte wet mass that can be used as green manure, feeds for farm animals, poultry and fish.
Źródło:
Journal of Ecological Engineering; 2022, 23, 5; 54--63
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności procesu koagulacji ścieków włókienniczych w warunkach przemysłowych
Effectiveness of textile wastewater coagulation treatment under industrial conditions assessment
Autorzy:
Bilińska, L.
Biliński, K.
Ledakowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/2073257.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ścieki włókiennicze
oczyszczanie ścieków
koagulacja
textile wastewater
wastewater treatment
coagulation-flocculation treatment system
Opis:
W pracy przedstawiono wyniki oczyszczania strumienia ścieków włókienniczych o wysokim stężeniu zanieczyszczeń za pomocą koagulacji. Na podstawie wskaźników charakteryzujących oczyszczone w skali laboratoryjnej ścieki (pH, indeksu osadu, temperatury, stężenia chlorków, ChZT, BZT) oceniono efektywność działania badanych koagulantów i flokulantów. Wybrano najlepszą parę środków. Efekty oczyszczania potwierdzono w skali przemysłowej. Udało się osiągnąć parametry oczyszczonych ścieków pozwalające na zrzut do miejskiej sieci kanalizacyjnej.
The paper presents the results of "high-loaded" wastewater stream coagulation-flocculation treatment. On the basic of indicators that characterized treatedin labolatory scale wastewater (pH, sludge index, temperature, chlorides, COD and BOD) the effectiveness of tasted coagulants and flocculants was assessed. The best coagulant-flocculant pair was chosen. Treatment effects were confirmed on an industrial scale. Limiting emission factors were achieved so dumping into municipal sewer was possible.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 143--145
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical modelling of marine power plants with thermochemical fuel treatment
Autorzy:
Cherednichenko, Oleksandr
Serbin, Serhiy
Tkach, Mykhaylo
Kowalski, Jerzy
Chen, Daifen
Powiązania:
https://bibliotekanauki.pl/articles/32907384.pdf
Data publikacji:
2022
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
marine power plants
thermochemical fuel treatment system
gas turbine engine
mathematical modeling
Opis:
The article considers the methodological aspects of the theoretical investigation of marine power plants with thermochemical fuel treatment. The results of the study of the complex influence of temperature, pressure, and the ratio of steam / base fuel on the thermochemical treatment efficiency are presented. The adequacy of the obtained regression dependences was confirmed by the physical modelling of thermochemical fuel treatment processes. For a gas turbine power complex with a thermochemical fuel treatment system, the characteristics of the power equipment were determined separately with further merging of the obtained results and a combination of material and energy flow models. Algorithms, which provide settings for the mathematical models of structural and functional blocks, the optimisation of thermochemical energy transformations, and verification of developed models according to the indicators of existing gas turbine engines, were created. The influence of mechanical energy consumption during the organisation of thermochemical processing of fuel on the efficiency of thermochemical recuperation is analysed.
Źródło:
Polish Maritime Research; 2022, 3; 99-108
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu systemu cyrkulacji na poziom stężeń mikrozanieczyszczeń w układzie oczyszczania wody basenowej
The impact of the circulation system on the concentration levels of micropollutants in the swimming pool water treatment system
Autorzy:
Lempart, A.
Kudlek, E.
Dudziak, M.
Szyguła, A.
Powiązania:
https://bibliotekanauki.pl/articles/399926.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system oczyszczania
woda basenowa
cyrkulacja wody
PPCPs
mikrozanieczyszczenia
pool water
treatment system
water circulation
micropollutants
Opis:
Każda instalacja basenowa powinna zapewniać prawidłową i stałą cyrkulację wody w systemie obiegu zamkniętego, która umożliwia przedłużenie czasu całkowitej wymiany wody nawet do 1 roku. Praca takiego systemu może jednak potencjalnie powodować podwyższenie stężenia małocząsteczkowych mikrozanieczyszczeń w układzie oczyszczania wody basenowej. Celem niniejszej pracy jest potwierdzenie lub odrzucenie niniejszej tezy. W ramach badań wstępnych przeprowadzono analizę zawartości substancji organicznych i nieorganicznych w wodzie basenowej na podstawie wskaźników ogólnych takich jak OWO, absorbancja UV254 i przewodność właściwa. W zasadniczym etapie badań, próbki wody basenowej pobierane z czterech różnych punktów instalacji zostały poddane analizie chromatograficznej w celu oznaczenia małocząsteczkowych mikrozanieczyszczeń organicznych. Badaniu poddano także wodę wodociągową stosowaną do napełnienia niecki i regularnego uzupełniania strat objętości. Badanie to miało na celu wykluczenie wody wodociągowej jako potencjalnie możliwego źródła pochodzenia zanieczyszczeń w wodzie basenowej. Przeprowadzone badania wstępne wykazały niemal dwukrotny wzrost zawartości ogólnego węgla organicznego oraz absorbancji UV254 po sześciu miesiącach, co niewątpliwie świadczy o możliwości gromadzenia się zanieczyszczeń organicznych w systemach cyrkulacji wody basenowej. Tego zjawiska nie zaobserwowano w przypadku związków nieorganicznych. W wyniku analiz chromatograficznych w wodzie basenowej oznaczono farmaceutyki i pozostałości kosmetyków. Stwierdzono, że w układzie oczyszczania wody basenowej miejscem największego gromadzenia się farmaceutyków jest zbiornik przelewowy, a pozostałości kosmetyków niecka basenowa. Na omawiane zjawisko ma wpływ czas trwania filtrocyklu.
Each pool installation should ensure proper and constant circulation of water in a closed circuit system. However, the operation of such a system can potentially cause the accumulation of small -molecule micropollutants in the pool water treatment system. The aim of this work is to confirm or reject this argument. As part of preliminary tests, the content of organic and inorganic substances in swimming pool water was analyzed based on general indicators such as TOC, UV254 absorbance and conductivity. In the main stage of the research, pool water samples collected from four different points of the swimming pool installation were subjected to chromatographic analysis to determine the small-molecule micropollutants. The tap water used to fill the basin and regular replenishment of volume losses was also tested. This study was intended to exclude the tap water as a potential source of contamination in the pool water. Preliminary studies have shown almost a two-fold increase in the total organic carbon content and absorbance UV254 at the turn of six months, which undoubtedly indicates the accumulation of organic pollutants in pool water circulation systems. It was not observed in the case of inorganic compounds. As a result of the chromatographic analyzes of the pool water, the content of pharmaceuticals and personal care product was determined. It was found that the compensation tank is the place of the highest accumulation of the tested pharmaceuticals in the pool water treatment system , while the cosmetics component accumulated in the pool basin to the greatest degree. It was affected by the duration of the filter cycle.
Źródło:
Inżynieria Ekologiczna; 2018, 19, 2; 23-31
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Suchy system oczyszczania spalin ze spalania odpadów niebezpiecznych - ocena skuteczności usuwania substancji gazowych i możliwości spełniania standardów emisyjnych
Dry flue-gas treatment system in hazardous waste incineration - assessment of efficiency of gaseous substances removal and possibilities of comply with emission limits
Autorzy:
Oleniacz, R.
Powiązania:
https://bibliotekanauki.pl/articles/296997.pdf
Data publikacji:
2009
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
odpady niebezpieczne
spalanie
gazy odlotowe
suchy system oczyszczania
hazardous wastes
incineration
flue gases
dry treatment system
Opis:
Obiektem badań była instalacja spalania odpadów medycznych o wydajności maksymalnej 150 kg/h, wyposażona w suchy system oczyszczania spalin, oparty na procesie adsorpcji zanieczyszczeń na sorbencie wapniowo-węglowym i zatrzymywaniu sorbentu w wysokosprawnym urządzeniu odpylającym (filtrze ceramicznym o gwarantowanym stężeniu pyłu na wylocie poniżej 5 mg/mn3). W charakterze sorbentu wykorzystywane było wysokoreaktywne wapno hydratyzowane z 5 ÷ 10% dodatkiem węgla aktywnego. Sorbent ten podawany był do spalin w minimalnych zalecanych ilościach (4 ÷ 5 kg/h). Celem badań była m.in. ocena skuteczności usuwania ze spalin wybranych substancji gazowych (SO2, NOx, HCl, HF, HCN i BTX) oraz możliwości spełniania standardów emisyjnych określonych dla instalacji spalania odpadów. Na podstawie przeprowadzonych pomiarów i analiz stwierdzono, że wysoką skuteczność oczyszczania otrzymano jedynie dla takich substancji, jak SO2, HCN i etylobenzen. Tego typu całkowicie suchy system oczyszczania spalin niezbyt dobrze radzi sobie z zatrzymywaniem niektórych zanieczyszczeń występujących w fazie gazowej (np. HCl), co w sytuacji okresowego wzrostu ilości substancji unoszonych z procesu spalania może skutkować niedotrzymywaniem standardów emisyjnych. Problem ten może dotyczyć także innych substancji (np. HF, NOx czy SO2) w przypadku spalania odpadów niebezpiecznych zawierających dużo wyższe ilości fluoru, azotu czy siarki. W tych przypadkach niezbędne jest stosowanie bardziej skutecznych metod ograniczania emisji do powietrza i/lub zoptymalizowanie pracy suchego systemu oczyszczania spalin.
The research object was a medical waste incineration plant with a capacity of 150 kg per hour equipped with a flue-gas treatment system based on dry sorption process using a lime-carbon reagent with adsorbent removing in high-efficiency particulate collector. As the dry sorption agent was used a mixture of high reactive hydrated lime and activated carbon injected to combustion gases by pneumatic feeder in the minimal recommended amount (4 ÷ 5 kg/h). Activated carbon content in the mixture was 5 ÷ 10% by mass. Applied collector was a ceramic filter with total filtration area of 120 m2 and guaranteed outlet dust concentration under 5 mg/mn3. One of the research aims was the evaluation of removal efficiency selected gaseous compounds (SO2, NOx, HCl, HF, HCN and BTX) from flue-gas and possibilities of comply with emission limit requirements for waste incinerators. Based on carried out measurements and analysis there was claimed that high efficiency of the flue-gas cleaning was only for such substances like SO2, HCN and ethylbenzene. This type of full dry flue-gas treatment system was not too adequate for other pollutants existing in gas phase (for example HCl). Consequently, the system could not comply with the emission standards during temporary increasing of the substances released from the incineration process. This problem did not occur with reference to the substances, which concentrations in raw gases were under emission limits (like HF and NOx), but during incineration of other hazardous wastes with much higher fluorine, nitrogen and sulphur content dry flue-gas cleaning could not be sufficient to the comply with emission standards for HF, NOx and SO2. In the cases, wet treatment or other methods of the emissions control might be necessary as well as improvement of the dry system operation connected with additional moisturizing and cooling of raw gases before the sorbent injection, increasing the sorbent mass flow and applying more powdered or impregnated adsorbents.
Źródło:
Inżynieria i Ochrona Środowiska; 2009, 12, 2; 85-99
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of Sewage Treatment Plants in the Sequential Batch Reactor
Efektywność oczyszczania ścieków w sekwencyjnych reaktorach biologicznych
Autorzy:
Jakubaszek, A.
Stadnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/396362.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
sewage treatment system
sequencing batch reactor
monitoring
efficiency
systemy oczyszczania ścieków
sekwencyjny reaktor biologiczny
wydajność
Opis:
The article analyzes the effectiveness of individual Actibloc wastewater treatment plants (produced by Sotralentz) working in the technology of low-rate activated sludge in the Sequential Batch Reactor (SBR) system. The assessment of the effectiveness of household wastewater treatment plants was made on the basis of pollutants: BOD5, COD, total suspended solids, total nitrogen and total phosphorus. The research objects were four household sewage treatment plants located in: Lubań, Kłębanowice, Stara Rzeka and Kościan. The efficiency of removing pollutants in the examined facilities was in the range of: BOD5 92.2 ÷ 97.2%, COD 82.6 ÷ 89.9%, total suspended solids 90.2 ÷96.2%, total nitrogen 50.8 ÷ 83.1%, total phosphorus 46.5 ÷ 73.6%. The treated wastewater met the requirements set out in the Regulation of the Minister of the Environment on the conditions to be met when discharging sewage into water or soil, and on substances particularly harmful to the aquatic environment (Journal of Laws 2014, item 1800) in terms of indicators such as BOD5, COD, total suspended solids and total nitrogen. The effectiveness of phosphorus removal in the studied treatment plants was much lower.
W artykule dokonano analizy efektywności funkcjonowania indywidualnych oczyszczalni ścieków Actibloc (producent: Sotralentz) pracujących w technologii niskoobciążonego osadu czynnego w systemie SBR. Oceny skuteczności pracy przydomowych oczyszczalni dokonano na podstawie badań wskaźników zanieczyszczeń: BZT5, ChZT, zawiesiny ogólnej, azotu ogólnego i fosforu ogólnego. Obiektami badań były cztery przydomowe oczyszczalnie ścieków zlokalizowane w miejscowościach: Lubań, Kłębanowice, Stara Rzeka i Kościan. Efektywność usuwania zanieczyszczeń w badanych obiektach była w zakresie: BZT5 92.2 ÷ 97.2 %, ChZT- 82.6 ÷ 89.9 %, zawiesina ogólna – 90.2 ÷ 96.2 %, azot ogólny –50.8 ÷ 83.1 %, fosfor ogólny – 46.5 ÷ 73.6 %. Ścieki oczyszczone spełniały wymagania określone w Rozporządzeniu Ministra Środowiska w sprawie warunków, jakie należy spełnić przy wprowadzaniu ścieków do wód lub do ziemi, oraz w sprawie substancji szczególnie szkodliwych dla środowiska wodnego (Dz. U. 2014 poz. 1800) w zakresie wskaźników takich jak: BZT5, ChZT, zawiesiny ogólnej i azotu ogólnego. Skuteczność usuwania fosforu ogólnego w badanych oczyszczalniach była zdecydowanie niższa.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(3); 121-131
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne systemy zmniejszające toksyczność spalin pojazdów kolejowych
Modern systems for reducing the toxicity of rail vehicle exhaust
Autorzy:
Merkisz-Guranowska, Agnieszka
Andrzejewski, Maciej
Daszkiewicz, Paweł
Gallas, Dawid
Stawecka, Hanna
Powiązania:
https://bibliotekanauki.pl/articles/34112021.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
toxicity of fumes
emissions
reduction
railway vehicle
treatment system
toksyczność spalin
emisja zanieczyszczeń
redukcja
pojazd kolejowy
układ oczyszczania
Opis:
W celu minimalizowania udziału substancji toksycznych w emitowanych przez silniki gazach wylotowych, należy ciągle, bo przepisy dotyczące emisji zanieczyszczeń są obecnie w szybkim tempie zmieniane i zaostrzane, pracować nad nowoczesnymi układami oczyszczania tych gazów. Wymagane jest zatem stosowanie coraz doskonalszych konstrukcyjnie oraz efektywniejszych rozwiązań, które zapewnią maksymalne zmniejszenie ilości toksycznych składników spalin. W artykule zaprezentowano przykładowe systemy znajdujące aktualnie zastosowanie w wybranych pojazdach kolejowych trakcji spalinowej.
In order to minimize the share of toxic substances in exhaust gases emitted by the engine it is necessary to continuously, because the provisions on emissions are now being rapidly changed and tightened, work on modern aftertreatment systems. It is, therefore, required that increasingly sophisticated and structurally efficient solutions that ensure maximum reduction of toxic exhaust are being used. The article presents examples of systems that are currently used in some diesel rail vehicles.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2016, Nr 3; 33-38
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Independent verification of treatment planning system calculations
Autorzy:
Dąbrowska-Szewczyk, Edyta
Zawadzka, Anna
Brzozowska, Beata
Walewska, Agnieszka
Kukołowicz, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2055675.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
3D-conformal radiotherapy
treatment planning system
quality control
validation of dose calculation
pre-treatment verification
Opis:
Purpose: According to the available international recommendations, at least one independent verifi cation of the calculations of number of monitor unit (MU) is required for every patient treated by teleradiotherapy. The aim of this study was to estimate the differences of dose distributions calculated with two treatment planning systems: Eclipse (Varian) and Oncentra MasterPlan (Elekta). Materials and methods: The analysis was performed for 280 three-dimensional conformal radiotherapy treatment (3D-CRT) plans with photon beams from Varian accelerators: CL 600C/D X6 MV (109 plans), CL 2300C/D X6 MV (43 plans), and CL 2300C/D X15 MV (128 plans). The mean doses in the planning target volume (PTV) and doses at the isocenter point obtained with Eclipse and Oncentra MasterPlan (OMP) were compared with Wilcoxon matched-pairs signed rank test. Additionally, the treatment planning system (TPS) calculations were compared with dosimetric measurements performed in the inhomogeneous phantom. Results: Data were analysed for 6 MV plans and for 15 MV plans separately, independently of the treatment machine. The dose values calculated in Eclipse were significantly (p <0.001) higher compared to calculations of OMP system. The average difference of the mean dose to PTV was (1.4 ± 1.0)% for X6 MV and (2.5 ± 0.6)% for X15 MV. Average dose disparities at the isocenter point were (1.3 ± 1.9)% and (2.1 ± 1.0)% for X6 MV and X15 MV beams, respectively. The largest differences were observed in lungs, air cavities, and bone structures. Moreover the variation in dosimetric measurements was less as compared to Eclipse calculations. Conclusions: OMP calculations were introduced as the independent MU verification tool with the first action level range equal to 3.5%.
Źródło:
Nukleonika; 2021, 66, 2; 47--53
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wirtualna radioterapia – nowe narzędzie w procesie edukacji fizyków medycznych
Virtual radiotherapy – a new tool in education process of medical physicists
Autorzy:
Buliński, Krzysztof
Kuszewski, Tomasz
Wnuk, Katarzyna
Kędzierawski, Piotr
Braziewicz, Janusz
Ślosarek, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2146762.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
akcelerator
fantom pomiarowy
system planowania leczenia
wirtualna radioterapia
accelerator
measurement phantom
treatment planning system
virtual radiotherapy
Opis:
Fizyk medyczny to zawód, który wymaga umiejętności zastosowania metod fizyki w medycynie. Jeżeli dziedziną medycyny jest radioterapia, wówczas należy nauczyć się wykorzystania metod pomiarowych promieniowania jonizującego (dozymetria kliniczna) oraz informatyki (systemy planowania leczenia) w praktyce klinicznej. W procesie dydaktycznym wymagane jest wykorzystanie sprzętu medycznego, który jest w codziennym użytku. Pojawia się konflikt (pozorny), czy aparatura medyczna ma być wykorzystywana do celów edukacyjnych, czy też leczenia chorych. W okresie, kiedy informatyka i związana z nią technologia bardzo dynamicznie się rozwijają, kwestią czasu było pojawienie się wirtualnych akceleratorów, symulatorów. Rozwiązanie to bardzo ułatwia, z punktu widzenia organizacji pracy, proces szkolenia nie tylko fizyków medycznych, ale również lekarzy oraz elektroradiologów obsługujących aparaty terapeutyczne w radioterapii.
Medical physicist is a profession that requires the ability to apply physics methods in medicine. If the field of medicine is radiotherapy, then you should learn how to use radiation measurement methods (clinical dosimetry) and computer science (treatment planning systems) in clinical practice. The teaching process requires the use of medical equipment that is in use daily. There is a conflict (an apparent one) whether medical equipment is to be used for educational purposes or for treating patients. In the period when IT and related technology is developing very dynamically, it was just the matter of time when virtual accelerators, simulators appear. In such virtual reality we can use these programs to move virtual accelerator’s gantry, collimator... This solution greatly facilitates, from the point of view of work organization, the training process not only of medical physicists, but also doctors and technicians in radiotherapy.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 3; 153--158
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in increment of trees diameters on plant-soil treatment system after long-term irrigation with domestic sewage
Zmiany przyrostów średnic drzew na terenie oczyszczalni roślinno-glebowej po okresie wieloletnich nawodnień ściekami bytowymi
Autorzy:
Pawęska, K.
Kuczewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/205045.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biomass
effluent irrigation
tree diameter
poplar
plant-soil treatment system
biomasa
ścieki bytowe
nawodnienia ściekami
przyrost drzew
topola
oczyszczalnia roślinno-glebowa
Opis:
Carbon dioxide sequestration and its long-term immobilisation in biomass is recently an extremely significant problem. Its greatest reserves occur in forests growing all over the globe. A human being, through their conscious action, ought to affect, among other things, the amount of carbon dioxide discharged into the atmosphere and its rational management. Here, quite a good solution seems to be the immobilisation of CO2 in biomass of plants, and in particular, in trees, characterised by their longevity, which are used most frequently for that purpose. Such carbon dioxide management allows for its several-decade immobilisation within living plants, while a further processing of wood mass allows for halting it for consecutive years in products manufactured. Additionally, in the case when within a selected land planted with trees the effluent irrigation is being carried out, simultaneous sewage treatment is also an advantage. By using plants characterised by intense increment in biomass within facilities, also biogens occurring in effluents may be effectively removed. In the analysed case, sewage treatment consisted in entry of household sewage into a prepared surface which was previously subject to mechanical purification. All the sections were sown with grass mixture and plantings of poplar were used. Observations were made during the period of 17 years. The effluents entered onto the surface of the sections and the effluents outflowing from the facility were subject to a physicochemical analysis in order to determine the operational efficiency of a plant - soil treatment system. Also, a threefold inventory of a forest stand was made in order to determine the increment in trees. The last inventory was made in 2014. Based on dendrological characteristics, the average volume of wood mass obtained from the land irrigated with effluents was assessed. A rational management of effluents on the grounds without any central drainage allows for a parallel solution to some problems. First of all, purification of effluents in a natural environment by closing the matter cycle, and additionally contributing to the limitation of carbon dioxide emission by its halting in plant biomass.
Sekwestracja dwutlenku węgla, jego długotrwałe unieruchomienie w biomasie jest ostatnio problemem niezwykle istotnym. Największe jego rezerwy znajdują się w lasach porastających kule ziemską. Człowiek poprzez swoje świadome działanie powinien wpływać między innymi na ilość dwutlenku węgla odprowadzanego do atmosfery oraz na racjonalne gospodarowanie nim. Dość dobrym rozwiązaniem zdaje się tu być unieruchomienie CO2 w biomasie roślin, a w szczególności w charakteryzujących się długowiecznością drzewach, które wykorzystywane są w tym celu najczęściej. Taka gospodarka dwutlenkiem węgla pozwala na kilkudziesięcioletnie unieruchomienie go w żywych roślinach, natomiast dalsza przeróbka masy drzewnej na zatrzymanie go przez kolejne lata w wytworzonych produktach. Dodatkowo w przypadku kiedy na wybranym, obsadzonym drzewami terenie prowadzi się nawodnienia ściekami, korzyścią jest również równoczesne oczyszczanie ścieków. Przy wykorzystaniu na obiektach roślin charakteryzujących się intensywnym przyrostem biomasy można również efektywnie usunąć biogeny znajdujące się w ściekach. W analizowanym przypadku oczyszczanie ścieków polegało na wprowadzeniu na przygotowaną powierzchnię ścieków bytowych, poddanych wcześniej mechanicznemu oczyszczeniu. Wszystkie kwatery obsiano mieszanką traw oraz zastosowano nasadzenia topolowe. Obserwacje prowadzono przez okres 17. lat. Analizie fizykochemicznej poddawano ścieki wprowadzane na powierzchnię kwater oraz odpływające z obiektu celem określenia skuteczności pracy oczyszczalni roślinno-glebowej. Przeprowadzono również trzykrotną inwentaryzację drzewostanu w celu określenia przyrostu drzew. Ostatnią inwentaryzację wykonano w roku 2014. Na podstawie charakterystyki dendrologicznej oszacowano średnią miąższość masy drzewnej uzyskanej z terenu nawadnianego ściekami. Racjonalna gospodarka ściekami na terenach bez centralnej kanalizacji pozwala na równoległe rozwiązanie kilku problemów. Przede wszystkim oczyszczanie ścieków w środowisku naturalnym poprzez zamykanie obiegu materii, a dodatkowo przyczynianie się do ograniczenia emisji dwutlenku węgla poprzez zatrzymywanie go w biomasie roślin.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 96-103
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of the organizational and legal mechanism of medical support of the security and defense sector of Ukraine in crises based on NATO standards
Autorzy:
Bakai, Andrii
Kupriienko, Dmytro
Powiązania:
https://bibliotekanauki.pl/articles/1933924.pdf
Data publikacji:
2020-12-31
Wydawca:
Wydawnictwo Adam Marszałek
Tematy:
integrated medical space of troops (forces)
interoperability
integrated treatment system
capability-based planning
principles and policy of health service support
military medicine reform
level system of medical support
control structure
Opis:
The article has considered the general principles and capabilities of the medical support of NATO troops, confirmed the expediency of further transformation of tasks and functions of the state in terms of medical support of troops (forces) of the security and defense sector of Ukraine in crises through the approximation to the relevant NATO standards, justified the need to implement the Euro-Atlantic experience of rendering medical care, use the general framework of categories and concepts, principles of the evaluation of capabilities (assets) of medical support which will contribute to the development of integrated medical space for medical defense of troops (forces) and elaboration of individual crisis response model taking into account the basic international requirements. The authors have determined the priority tasks of further cooperation between Ukraine and the North Atlantic Treaty Organization in the context of the reforms of medical logistics. It has been substantiated the need to keep reforming military medicine in conformity with NATO standards and recommendations that will promote an active involvement of medical services of troops (forces) in medical support of national and multi-domestic contingents during crises and adaptation of interoperable medical capabilities of joint missions under the auspices of NATO and the UN. The research has analyzed the mechanisms of interdepartmental coordination on medical support of troops (forces) and proved the feasibility of using the experience of NATO member states in the organization and functioning of the system of medical support of the military contingent with the adaptation of NATO doctrinal documents to the realities of modern Ukraine.
Źródło:
Reality of Politics; 2020, 14; 13-32
2082-3959
Pojawia się w:
Reality of Politics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Matematicheskaja model' processa podgotovki maslichnogo syr'ja v mnogochannojj zharovne
Mathematical models of processes preparation of oilseeds in the brazier
Autorzy:
Didur, V.
Tkachenko, V.
Tkachenko, A.
Powiązania:
https://bibliotekanauki.pl/articles/77893.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
mathematical model
multicapacitor brazier
thermal balance
boundary condition system
drive system
moisture treatment
heat treatment
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2016, 18, 1
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków bytowo-gospodarczych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych
The efficiency of domestic sewage tretment in ground-plant and soil-plant treatment units
Autorzy:
Czyżyk, F.
Pulikowski, K.
Strzelczyk, M.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338757.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie glebowo-roślinne
oczyszczanie ścieków
reed bed system
soil-plant treatment
wastewater treatment
Opis:
Celem badań prezentowanych w pracy było rozpoznanie zmian efektywności oczyszczania ścieków bytowych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych w zależności od czasu i warunków ich eksploatacji. W pracy przedstawiono wyniki badań skuteczności oczyszczania ścieków w złożach gruntowo-trzcinowych, zbudowanych wg systemu Kickutha, oraz oczyszczalni glebowo-roślinnej w początkowym okresie eksploatacji (na 4 obiektach) i po 15 latach (na 2 obiektach). Zaskakujące były zdecydowanie różniące się wyniki, uzyskane w pierwszych latach eksploatacji, z dwóch podobnych złóż gruntowo-trzcinowych, których eksploatację rozpoczęto w tym samym roku. Na jednym skuteczność oczyszczania zwiększała się z upływem czasu, a na drugim wystąpiły objawy braku tlenu w złożu i słabej nitryfikacji azotu, co przejawiało się dużym stężeniem N-NH4 w odpływach z oczyszczalni. Przyczyną tego była błędna lokalizacja oczyszczalni - w miejscu silnie zacienionym, co wpłynęło na bardzo słaby rozwój trzciny i jej systemu korzeniowego, a tym samym na słabe napowietrzanie złoża. Z upływem lat eksploatacji pogarszała się przepuszczalność złóż dwóch badanych oczyszczalni gruntowo-trzcinowych i wystąpiło ich zakolmatowanie, powodowane głównie niedostatecznym oczyszczaniem wstępnym doprowadzanych ścieków. Stwierdzono znacznie wyższy stopień oczyszczania ścieków w oczyszczalni glebowo-roślinnej, zarówno w początkowym okresie eksploatacji, jak i po 15 latach. Uzyskane zmniejszenie głównych wskaźników zanieczyszczenia po 15 latach eksploatacji gruntowo-trzcinowych było następujące (w %): Nog - 47, Pog - 63, BZT5 - 93, ChZTCr - 81, natomiast na oczyszczalni glebowo-roślinnej: Nog - 84, Pog - 99, BZT5 - 95, ChZTCr - 74.
The aim of this study was to trace changes in the efficiency of domestic sewage treatment in soilplant and ground-plant systems in relation to the time and conditions of use. The paper presents results of testing the effectiveness of sewage treatment in ground reed beds constructed according to Kickuth system and in soil-plant treatment units, in the beginning of utilization period (in 4 objects) and after 15 years (in 2 objects). Surprising were the definitely different results obtained during the first years of utilization in two similar reed beds, which started operating in the same year. In one, the efficiency of treatment increased with time and in the other the symptoms of oxygen deficit and weak nitrification were observed in the bed which manifested itself in high N-NH4 concentrations in the outflow from the treatment unit. The reason was in faulty location of the treatment unit in an intensely shaded place resulting in poor development of reed and its root-rhizome system and, consequently, in poor aeration of the bed. In the two examined ground reed treatment units, the beds lost their permeability and became silted with time due mainly to insufficient primary sewage treatment. The soil-plant treatment unit showed considerably higher degree of sewage purification, both during the initial period of utilization and after 15 years. In ground reed beds, after 15 years of their utilization, the reduction of main pollutants was (in %): Ntot - 47, P - 63, BOD - 93, CODCr - 81, whereas in soil-plant treatment units it was: Ntot - 84, P - 99, BOD - 95, CODCr - 74.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 97-108
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of Craft Brewery Sewage with SS VF and FWS Constructed Wetland – Lab Scale Experiment
Autorzy:
Dąbrowski, Wojciech
Karolinczak, Beata
Malinowski, Paweł
Lech, Magrel
Powiązania:
https://bibliotekanauki.pl/articles/2069918.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
craft brewery
sewage treatment
constructed wetlands
subsurface flow system
surface flow system
Opis:
The problem of wastewater treatment from craft breweries emerged in Poland about 10 years ago when an increase in the number of small breweries was observed. Plants located in small towns are forced to solve the problem on their own. One of the possibilities is to use low-cost technology of constructed wetlands with subsurface and surface flow. The purpose of the research was to test the possibility of effective treatment of sewage from a craft brewery in a lab-scale research installation and to determine the parameters for designing a real scale plant. Wastewater from the Waszczukowe brewery was used in the study. The research system consisted of a retention and aeration tank, SS-VF subsurface flow and FWS surface flow beds. An innovative Certyd filling produced by LSA company was used. The high efficiency of SS-VF bed and the entire research system was found. The removal efficiency in SS VF was on average 89.7% for BOD5, 90.5% for COD, 54.6% for TN and 52.1% for TP. For whole treatment it was respectively 97.1%, 96.7%, 72.6% and 61.3%. A high organic matter removal effect was found for the SS-VF bed (87.1 g BOD5g m-2 d-1) and a relatively low for the FWS (3.0 BOD5g m-2 d-1). The study confirmed the need for plant design based on hydraulic load and required load removed per unit area.
Źródło:
Rocznik Ochrona Środowiska; 2021, 23; 290--300
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Status of the Water Supply and Sanitation Infrastructure in the Kraśnik County
Autorzy:
Gizińska-Górna, Magdalena
Gawron, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/123147.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sanitation infrastructure
commune
water supply system
sewerage system
wastewater treatment plant
cesspool
Opis:
The paper describes the status of water supply and sanitation infrastructure in the Kraśnik County. The description is based on the official statistical data and the data obtained in a survey carried out in 2016. The Kraśnik County is located in the Lublin Province and comprises 10 communes: one urban commune (the Municipality of Kraśnik), two urban-rural communes (Annopol and Urzędów), and seven rural communes (Dzierzkowice, Gościeradów, Kraśnik, Szastarka, Trzydnik Duży, Wilkołaz, and Zakrzówek). In 2016, an average of 90.9% of the County’s inhabitants had the access to the mains water, but only 13.5% were connected to the mains sewerage. The County has six centralized wastewater treatment plants with a total capacity of approximately 14.164 m3/d. The survey data showed that the records of cesspools were kept in only four of the County’s communes: the Municipality of Kraśnik, Urzędów, Wilkołaz, and Zakrzówek. The total number of cesspools in those communes was 4776. The Kraśnik County is in great demand for the construction of on-site domestic wastewater treatment plants, which are an excellent alternative to cesspools. The network of domestic wastewater treatment plants in the Kraśnik County is made up almost entirely of systems with a drainfield, which may pose a serious threat to the soil and water environment. The results of the present study suggest that Commune Offices must take decisive steps to eliminate the existing disproportion between the coverages of the sewerage and water supply systems in the County’s communes.
Źródło:
Journal of Ecological Engineering; 2020, 21, 4; 168-177
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania efektywności pracy oczyszczalni gruntowo-roślinnych i wodno-roślinnych typu "Lemna"
Effectiveness of sewage treatment plants involving soil-vegetable and water-vegetable (Lemna-type)
Autorzy:
Czyżyk, F.
Powiązania:
https://bibliotekanauki.pl/articles/236596.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczalnie hydrobotaniczne
system Lemna
hydrophyte treatment systems
Lemna-type
Opis:
Omówiono wyniki badań efektywności pracy czterech hydrobotanicznych oczyszczalni ścieków. Badania przeprowadzono w latach 1996-1998 na pracujących od 1995 r. dwóch oczyszczalniach gruntowo-trzcinowych (Morawa i Szklarka) oraz dwóch oczyszczalniach wodno-roślinnych typu "Lemna" (Kochcice i Pawonków). Stwierdzono, że efektywność oczyszczania ścieków w badanych oczyszczalni była bardzo zróżnicowana, co było spowodowane odmiennymi warunkami ich pracy. Oczyszczalnia gruntowo-trzcinowa w Morawie nie dawała dobrych efektów oczyszczania ścieków z uwagi na błędna lokalizację, gdyż została ona umieszczona w terenie zacienionym, co skutkowało słabym systemem korzeniowym. Wymagany stopień oczyszczania ścieków uzyskano dopiero w stawie doczyszczającym. Wyniki oczyszczania ścieków w dwóch oczyszczalniach typu "Lemna" były również zróżnicowane. Usuwanie zanieczyszczeń na oczyszczalni w Kochcicach było znacznie niższe niż w Pawonkowie. Szczególnie niskie było usuwanie związków azotu i fosforu. Oczyszczalnia w Kochciacach pracowała jednak w warunkach dużego przeciążania ściekami w stosunku do obciążeń projektowanych. Kontrolne badania na oczyszczalniach typu "Lemna" wykonane w 2000 r. wykazały oznaki pogorszenia pracy oczyszczalni wraz z ich wiekiem. Wystąpiły objawy wtórnego zanieczyszczania odpływających ścieków, takie jak wzrost zawartości zawiesin ogólnych, azotu amonowego i natężenie uciążliwych zapachów, czego przyczyną było gromadzenie się słabo ustabilizowanych osadów organicznych na dnie stawów doczyszczających i ich fermentacja.
The investigations covered the time span of 1996-1998 and were carried out in two sewage treatment plants working with a soil-reed bed (Morawa and Szklarka) and two sewage treatment plants involving a Lemna-type water-vegetable bed (Kochcice and Pawonków). Treatment efficiency was found to vary from one plant to another, which should be attributed to the differences in the operating conditions. The low treatment efficiency obtained with the soil-reed bed in Morawa should be attributed to the location of the treatment plant in a shaded area, which resulted in a poorly developed root system. The desired treatment effect was achieved only after having passed the wastewater to the secondary pond. The treatment efficiencies obtained in the two Lemna-type plants also differ from each other. The treatment effects in Kochcice were much poorer than in Pawonków, and this holds particularly for the removal of nitrogen and phosphorus compounds. It was so because the Kochcice plant worked under a high overloading as compared to the design value. A testing study of the two Lemna-type sewage treatment plants carried out in 2000 revealed a continuing decrease in treatment efficiency with time. There were symptoms of self-contamination in the effluent (increased TSS, ammonia nitrogen, intensifying objectionable odour) produced by the accumulation of poorly stabilized organic sludges on the bottom of the secondary pond.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 2, 2; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the distribution of statistical concentrations of pollutants in samples of treated wastewater from small sewage treatment plants
Autorzy:
Kaczor, Grzegorz B.
Powiązania:
https://bibliotekanauki.pl/articles/2174301.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
pollutants
sewer system
significance test
statistical distribution
treatment plant
Opis:
The aim of the research was to show which theoretical statistical distribution best reflects and describes the variability of pollutant concentrations in treated sewage, discharged from small sewage treatment plants, characterised by a value below 2000 PE. The statistical analysis additionally takes into account the influence of the number of measuring sequence data on the shape and level of the distribution fit. The data for the research were obtained from three small sewage treatment plants, operating in the Lesser Poland, 10, 11 and 14 km from Kraków. Due to their size, these facilities are included in the group of treatment plants below 2000 PE. The research was conducted for 10 years. In the statistical analysis, 20-, 40-, 60- and 80-element data series were used, including the values of biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr) and total suspended solids (TSS), determined in samples of treated wastewater. Two commonly used tests, Kolmogorov-Smirnov λ and Pearson’s χ2 test were used to assess the fit of the theoretical statistical distribution to the empirical data distribution. Statistical analysis showed that the studied communities were characterised by an asymmetric, right-oblique distribution. Most often, the empirical distribution of the analysed measurement sequences was consistent with the Fisher-Tippett distribution. On the basis of the χ2 test, this distribution was described by a total of 31 out of 36 analysed groups at the significance level of a = 0.05. Other distributions that often describe the analysed empirical data are: Gamma, log-normal, Chi-square, and Weibull. The common feature of these distributions is usually asymmetry, right oblique. The skewness value ranges from 0.15 to 1.69.
Źródło:
Journal of Water and Land Development; 2022, 55; 115--124
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of filtration materials (Polonite® and Leca®) supporting phosphorus removal in on site treatment systems with wastewater infiltration
Autorzy:
Karczmarczyk, A.
Woja, K.
Bliska, P.
Baryła, A.
Bus, A.
Powiązania:
https://bibliotekanauki.pl/articles/101107.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
phosphorus
reactive material
on site wastewater treatment
infiltration system
Opis:
The most of the on site wastewater treatment systems in Poland discharges treated effluent to the soil. The goal of phosphorus (P) reduction from dispersed sources of pollution can be achieved by application of P reactive materials in the construction of wastewater infiltration systems. Two P reactive materials were tested in this study: Polonite® in grains of 2÷6 mm and lightweight aggregate Leca® in grains of 4÷10 mm. Apparent P sorption capacity was assesed on 40.9 mg·g-1 (Polonite®) and 5.1 mg·g-1 (Leca®). Both materials sorbed P-PO4 very fast, after 15 min over 90% of P was removed from solution and wastwater. Wastewater used in this study came from the outlet from the septic tank of on site septic system. P-PO4 solution was prepared from KH2 PO4 and the tap water. In the small column experiment, four collumns (2 filled with Polonite® and 2 filled with Leca®) were fed with wastewater and P-PO4 solution in hydraulic loadings of 30÷40 dm3 ·m-2·d-1. All the columns removed significant amounts of P from both solution and wastewater with the reduction between 28.3% and 72.5%. The mean P-PO4 effluent concentrations ranged from 1.21 mg·dm-3 to 7.12 mg·dm-3. The best overall performance was achieved by the Polonite® fed with solution. Both tested materials can support wastewater treatment in on site systems.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1401-1413
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tworzenie i udostępnianie dokumentacji medycznej - proces informatyzacji systemu ochrony zdrowia
Creating and Providing Access to Medical Documentation – Introduction of IT Solution to the Health Protection System
Autorzy:
Gostyńska, Maria
Powiązania:
https://bibliotekanauki.pl/articles/416392.pdf
Data publikacji:
2016-08
Wydawca:
Najwyższa Izba Kontroli
Tematy:
medical dicumentation
digitalisation of system
health protection system
medical treatment
diagnosis and therapy
Opis:
It is mandatory, in the light of legal provisions, that all important information should be saved in personal medical documentation of a patient. This procedure is of vital importance, because it not only records the medical treatment of a given patient applied by medical staff, but it also provides a form of mutual informing on the patient’s condition during diagnosis and therapy. The procedure for creating and providing access to medical documentation has not been audited by NIK to date. However, pre-audit examination revealed that the manner in which such documentation is kept does not meet the current standards, and that patients have difficulties with accessing their documentation when they wish to continue treatment at another medical entity, or when they claim that a doctor has made a mistake during therapy.
Źródło:
Kontrola Państwowa; 2016, 61, 4 (369); 84-97
0452-5027
Pojawia się w:
Kontrola Państwowa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of Sanitary Infrastructure in the Parczew District and the Need for its Development
Autorzy:
Micek, A.
Marzec, M.
Jóźwiakowska, K.
Pochwatka, P.
Powiązania:
https://bibliotekanauki.pl/articles/123430.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sanitary infrastructure
commune
water supply system
sewerage system
wastewater treatment plant
septic tank
Opis:
The aim of this paper is to present the current state and the need for development of sanitary infrastructure in the communes of Parczew District, in Lublin Voivodeship. Parczew District encompasses seven communes: Parczew, Dębowa Kłoda, Jabłoń, Milanów, Podedwórze, Siemień, and Sosnowica. The present paper uses the data from the surveys conducted in these communes in 2016. On average, 88% of the population used the water supply system in the communes surveyed, while 48% of the inhabitants were connected to a sewerage system. Parczew District had 12 collective mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3/d. The households which were not connected to the sewerage network discharged the wastewater mainly to non-return tanks. In the communes surveyed, 1,115 households had domestic wastewater treatment plants. All of them were systems with infiltration drainage, which do not ensure high efficiency of removing pollutions and may even contribute to the degradation of the groundwater quality. In order to solve the existing problems of sewage and water management in the communes of Parczew District, it is necessary to further develop the collective sewerage systems and equip the areas which have a dispersed development layout with highly efficient domestic treatment plants, such as constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 107-115
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the BIOLOG system for characterization of Serratia marcescens ss marcescens isolated from onsite wastewater technology (OSWT)
Autorzy:
Chojniak, Joanna
Jałowiecki, Łukasz
Dorgeloh, Elmar
Hegedusova, Berta
Ejhed, Helene
Magnér, Jörgen
Płaza, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1038922.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
onsite wastewater treatment
Biolog system
Serratia spp.
antibiotic resistance
Opis:
The scope of this study was to apply the Biolog system to identify and characterize a Serratia strain isolated from the surface of black plastic pieces which constitute the fluidized bed filter (onsite wastewater technology, OSWT). The preliminary isolation of the strain was done in the medium with tetracycline at a 16 mg/l concentration. To characterize the isolated strain, the following Biolog methods were applied: (1) EcoPlates microplates for evaluation of physiological profiling, (2) GEN III OmniLog® ID System for identification of the isolate, and (3) phenotypic microarrays (PM) technology for evaluation of sensitivity to antibiotics (PM11 and PM12). Results were recorded using the original OmniLog® software. The Serratia strain was identified as Serratia marcescens ss marcescens with similarity index 0.569. The same identification was obtained by the 16S rDNA analysis. PM analysis showed an enhancement of phenotype (resistance or growth) of this strain to 35 antibiotics. The loss of phenotype (sensitivity or non-growth) was observed only for 5 antibiotics: lomefloxacin (0.4 µg/ml), enoxacin (0.9 µg/ml), nalidixic acid (18.0 µg/ml), paromomycin (25.0 µg/ml) and novobiocin (1100 µg/ml). This study acknowledges that the methods proposed by the Biolog system allow correct and complete identification and characterization of the microbes isolated from different environments. Phenotypic microarrays could be successfully used as a new tool for identification of the multi-antibiotic resistance of bacteria and for determination of the minimal inhibition concentrations (MIC).
Źródło:
Acta Biochimica Polonica; 2015, 62, 4; 799-805
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa technologia dezynfekcji wody w MPWiK SA w Krakowie
New water disinfection technology in MPWiKSA in Kraków
Autorzy:
Biedrzycka, A.
Powiązania:
https://bibliotekanauki.pl/articles/366069.pdf
Data publikacji:
2014
Wydawca:
Nowoczesne Budownictwo Inżynieryjne
Tematy:
Kraków
uzdatnianie wody
system dezynfekcji promieniami UV
system dezynfekcji podchlorkiem sodu
water treatment
UV disinfection system
Opis:
Wzrost bezpieczeństwa bakteriologicznego i poprawa walorów smakowych wody dostarczanej mieszkańcom Krakowa to główne cele dużej inwestycji, jaką Miejskie Przedsiębiorstwo Wodociągów i Kanalizacji SA w Krakowie zrealizowało w Zakładzie Uzdatniania Wody Raba, który jest największym producentem wody dla Krakowa.
The increase in bacteriological safety and improvement of taste quality of water being supplied to Krakow inhabitants are the main aims of a major project completed by Miejskie Przedsiębiorstwo Wodociągów i Kanalizacji SA (Municipal Water and Sewage Company) in the Raba Water Treatment Plant which is the largest water provider in Kraków.
Źródło:
Nowoczesne Budownictwo Inżynieryjne; 2014, 5; 28-31
1734-6681
Pojawia się w:
Nowoczesne Budownictwo Inżynieryjne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrobotaniczne oczyszczalnie ścieków
Autorzy:
Gołąb, M.
Nocoń, W.
Michalski, R.
Powiązania:
https://bibliotekanauki.pl/articles/273982.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
oczyszczanie ścieków
oczyszczalnia ścieków
hydrobotaniczna oczyszczalnia ścieków
system Lemna
wastewater treatment
wastewater treatment plant
hydrobotanic wastewater treatment plant
Lemna-type
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 4; 6-10
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of heavy precipitation on the infiltration and inflow into small sewage treatment plants in 2010
Autorzy:
Kaczor, G.
Powiązania:
https://bibliotekanauki.pl/articles/60233.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
heavy rainfall
infiltration
inflow
small sewage treatment plant
sewage treatment plant
sewer system
weather
treatment plant
Malopolska voivodship
Krakow city
mechanical treatment plant
biological treatment plant
modernization
Opis:
The aim of the study was to determine the extent to which heavy rainfall, that occurred in 2010, affected the infiltration into the selected sewage treatment plants in the Małopolskie voivodeship. The research was conducted in four separate sewer systems, located in poviats adjacent to the city of Kraków, discharging sewage to mechanical-biological treatment plants with a capacity below 1000 m3•d-1. The amount of sewage and extraneous water in the average wet year (2008) were used as control. As a result of heavy precipitation in 2010 the sewer system A received 18 539 m3 more extraneous water than in 2008 (increase by 343%), the sewer sys-tem B - 22 822 m3 (increase by 163%), the sewer system C - 109 715 m3 (increase by 248%) and the sewer system D - 30 796 m3 (increase by 303%). Heavy precipitation in 2010 caused the increase of infiltration and inflow by 264% on average in all studied sewer systems compared to the average wet year. As the result of precipitation, whose annual total in 2010 was higher by 65% than the normal value in 2008, there was an increase in the annual share of extraneous water from 5.3 to 19.7% depending on the facility. The volume of extraneous water, which was discharged into the studied treatment plants in 2010 (the period of heavy rainfall), constituted the following share of the annual value: in the sewer system A - 41.3%, in the sewer system B - 21.2%, in the sewer system C - 14.4%, in the sewer system D - 22.9%. Assuming the average gross amount of 3 PLN paid for treatment of 1 m3 of sewage, cost of extraneous water disposal in 2010 amounted from 78 533 PLN to 552 165 PLN, depending on the facility. The results obtained in the present study suggest that eliminating or reducing infiltration and inflow into the analyzed sewer systems would allow for large financial savings associated with reducing costs both for their transport and treatment as well as for modernization of facilities to enhance their hydraulic eapacity.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2011, 12
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narzędzia informatyczne w technologii oczyszczania ścieków na przykładzie oczyszczalni ścieków w gminie Kaczory
Advanced IT tools in wastewater treatment technology based on example of sewage wastewater treatment plant in Kaczory
Autorzy:
Stankiewicz, Monika
Stankiewicz, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/449661.pdf
Data publikacji:
2019-12-08
Wydawca:
Zachodniopomorska Szkoła Biznesu w Szczecinie
Tematy:
system sterowania oczyszczalnią ścieków
system monitorowania oczyszczalni ścieków
narzędzia informatyczne w technologii oczyszczania ścieków
system SCADA
wastewater treatment technology
advanced IT tools in wastewater
treatment technology
SCADA
Opis:
W niniejszym artykule omówiono rolę i możliwości narzędzi informatycznych w technologii oczyszczania ścieków. Celem jest przedstawienie funkcjonalności systemów komputerowych i diagnostycznych w pracy tak zaawansowanych technologicznie obiektów jakim są oczyszczalnie ścieków i korzyści jakie przynosi ich stosowanie, również w odniesieniu do środowiska naturalnego. Na przykładzie oczyszczalni ścieków w gminie Kaczory (powiat pilski) zaprezentowano autorskie rozwiązanie typu SCADA (zaprojektowane specjalnie na potrzeby tego obiektu), jego możliwości i przykładowe wyniki pracy: wizualizacje z systemu monitorowania i sterowania oczyszczalnią ścieków oraz raporty z pracy.
In this article it has been explained role and capabilities of IT tools supporting technology of wastewater treatment. The goal of article is a presentation of advanced computer and diagnostic systems functionality used by sewage treatment plant and benefits of IT tools supporting wastewater treatment process in a reference to natural environment. Based on example of sewage treatment plant Kaczory (Piła County) it has been presented unique solution type SCADA (dedicated design for this object), capabilities and example wastewater treatment process reports: visualization, monitoring and control systems for sewage wastewater treatment plant with process reports.
Źródło:
Zeszyty Naukowe ZPSB Firma i Rynek; 2019, 2(56); 85-94
2657-3245
Pojawia się w:
Zeszyty Naukowe ZPSB Firma i Rynek
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of the Sanitary Infrastructure in the Ryki District in Poland and the Need for its Development
Autorzy:
Jóźwiakowska, Karolina
Micek, Agnieszka
Kanios, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1839635.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
district
septic tank
household wastewater treatment plants
collective wastewater treatment plants
water supply network
sewage system
Opis:
The aim of this paper was to present the current state and the need for development of the sanitary infrastructure in the communes of the Ryki District located in the Lublin Voivodeship. The Ryki District encompasses 1 urban Commune – Dęblin, 1 urban-rural Commune – Ryki and 4 rural communes: Kłoczew, Nowodwór, Stężyca and Ułęż. The paper is based on the data from the surveys conducted in all the afore-mentioned communes in 2016. In the whole district on average 71.3% of the population used the water supply network, while 42% of the inhabitants were able to discharge wastewater to the sewage system. Within the area of the Ryki District, 5 collective wastewater treatment plants with a capacity exceeding 5 m3/d functioned in 2016. The households which were not connected to the sewage network discharged wastewater mainly to non-return tanks. About 440 household sewage treatment plants were found in the surveyed communes. The overwhelming majority of such small objects in the discussed district were activated sludge systems (92%). The research carried out in 2016 proved a strong need to develop the current state of the sanitary infrastructure in the Ryki District. A particular emphasis should be placed on the wastewater management by connecting the inhabitants of urban areas to a joint sewage disposal system. Ecological awareness must be raised so as to encourage people to invest in household wastewater treatment plants, which should be used in the areas with scattered development.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 256-264
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Condition of the Sanitary Infrastructure in the Bialski District in Poland and the Need for its Development
Autorzy:
Jóźwiakowska, Karolina
Marzec, Michał
Powiązania:
https://bibliotekanauki.pl/articles/124925.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
district
septic tank
household wastewater treatment plants
collective wastewater treatment plants
water supply network
sewerage system
Opis:
The aim of this paper was to present the current state and the need for development of the sanitary infrastructure in the communes of the Bialski District located in the Lublin Voivodeship. The Bialski District encompasses 2 urban communes: Miedzyrzec Podlaski and Terespol and 17 rural communes: Biała Podlaska, Drelów, Janów Podlaski, Kodeń, Konstantynów, Leśna Podlaska, Łomazy, Międzyrzec Podlaski, Piszcząc, Rokitno, Rossosz, Sławatycze, Sosnówka, Terespol, Tuczna, Wisznice and Zalesie. The present paper uses the data from the surveys conducted in these communes in 2016. On average, 79.2% of the population used the water supply system in the surveyed communes, while 39.4% of the inhabitants had the possibility of discharging wastewater to the sewerage system. In the area of the communes, there were 20 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3/d. The households which were not connected to the wastewater network, discharged wastewater mainly to non-return tanks. In the surveyed communes, there were 4437 household wastewater treatment plants. Most of them (above 80%) were the systems with infiltration drainage, which do not ensure high efficiency of pollutants removal and may even contribute to the degradation of the groundwater quality. In order to solve the existing problems of wastewater and water management occurring in the communes where the Bialski District is located, it is necessary to further develop collective wastewater systems and equip the areas characterized by dispersed housing with highly efficient household treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2020, 21, 5; 155-163
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Azo dye wastewater treatment in a novel process of biofilm coupled with electrolysis
Autorzy:
Zou, Haiming
Chu, Lin
Wang, Yang
Powiązania:
https://bibliotekanauki.pl/articles/204706.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
azo dye wastewater treatment
color removal
biofilm
electrolysis
bioelectrochemical system
Opis:
Azo dye wastewater treatment is urgent necessary nowadays. Electrochemical technologies commonly enable more efficient degradation of recalcitrant organic contaminants than biological methods, but those rely greatly on the energy consumption. A novel process of biofilm coupled with electrolysis, i.e., bioelectrochemical system (BES), for methyl orange (MO) dye wastewater treatment was proposed and optimization of main influence factors was performed in this study. The results showed that BES had a positive effect on enhancement of color removal of MO wastewater and 81.9% of color removal efficiency was achieved at the optimum process parameters: applied voltage of 2.0 V, initial MO concentration of 20 mg/L, glucose loads of 0.5 g/L and pH of 8.0 when the hydraulic retention time (HRT) was maintained at 3 d, displaying an excellent color removal performance. Importantly, a wide range of effective pH, ranging from 6 to 9, was found, thus greatly favoring the practical application of BES described here. The absence of a peak at 463 nm showed that the azo bond of MO was almost completely cleaved after degradation in BES. From these results, the proposed method of biodegradation combined with electrochemical technique can be an effective technology for dye wastewater treatment and may hopefully be also applied for treatment of other recalcitrant compounds in water and wastewater
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 38-43
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określenie potencjalnych możliwości usuwania związków organicznych w sieci kanalizacyjnej
Determination of Potential Possibility of Organic Compounds Removal in a Sewer System
Autorzy:
Dymaczewski, Z.
Komorowska-Kaufman, M.
Krajewski, P.
Michałkiewicz, M.
Jeż-Walkowiak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1817991.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
system kanalizacyjny
usuwanie związków organicznych
wastewater treatment
sewage system
organic compounds removal
Opis:
The sewerage is an often skipped element of the wastewater treatment system. Because of its high retention capacity and relatively long flow time, it has to be considered that processes affecting wastewater composition and their vulnerability to biological treatment may occur in the sewerage. Changing hydraulic conditions in collectors and numerous side influents providing new portions of wastewater diversified in quantity and quality cause difficulties in a precise description of biochemical transformations occuring during wastewater flow in gravity sewers. The authors conducted research on changes in organic compounds (expressed as total COD) and their dissolved form (soluble COD) in wastewater, during their flow through the laboratory model of a gravity collector. The model is constructed as a cascade of five basins made from acrylic glass, 1.12 L each. Wastewater flowed through the model continuously with the rate of 0.5 L/h. It allowed to achieve the flow time of 11 hours, which is 2-3 times longer than flow times occuring in a typical large sewer network and enabled to take samples in the collector profile. Reaeration process, pH and temperature, as well as the psychro and mezophilic bacteria were also taken into account in the analysis. The results of two research series were presented in the article, i.e. where wastewater flowed continuously through the model for 17 and 33 days, respectively. It was proven that during flow in a collector, a number of processes takes place, including sedimentation, washing out of solid contaminations, removal of dissolved organic compounds and enzymatic hydrolysis of slowly biodegradable organic matter. Biomass growth in bulk wastewater and on the model wall proved that biological processes occur there. There are significant differences between research series, mainly caused by the temperature. It was observed that the amount of biofilm was rather small and did not exceed 5% of total biomass. Removal of total COD was in the range of 28.8-80.3 mg O2/(L h) and soluble COD from 8.5 to 11.5 mg O2/(L h). In the last part of the model, the rate od COD removal decreased due to the lack of substrate, which is in accordance with data given by other researchers.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 518-529
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lean thinking in a healthcare system - innovative roles
Autorzy:
Cooper, R.G.
Mohabeersingh, C.
Powiązania:
https://bibliotekanauki.pl/articles/3059.pdf
Data publikacji:
2008
Wydawca:
Instytut Medycyny Wsi
Tematy:
lean thinking
health care system
innovation
strategy
policy
hospital
treatment
Źródło:
Journal of Pre-Clinical and Clinical Research; 2008, 02, 2
1898-2395
Pojawia się w:
Journal of Pre-Clinical and Clinical Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Two Nonlinear Predictive Control Algorithms for Dissolved Oxygen Tracking Problem at WWTP
Autorzy:
Piotrowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/384859.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
aeration
dissolved oxygen
wastewater treatment
mathematical modelling
nonlinear system
predictive control
Opis:
The wastewater treatment plant is classified as a complex system due to its nonlinear dynamics, large uncertainty in the disturbance inputs, multiple time scales in the internal process dynamics and multivariable structure. Aeration is an important and expensive activity that is carried out during wastewater treatment plant operation. A precise aeration control in biological processes for all the operating conditions is necessary in order to guarantee adequate biological conditions for microorganisms. Therefore, the most important is to operate the biological processes so that a minimal energy was consumed and minimal DO concentration demand was applied. The paper proposes a two advanced control systems to track the dissolved oxygen reference trajectory. A decentralized and multivariable nonlinear predictive control algorithms are designed and compared. Simulation tests for the case study wastewater treatment plant are presented.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2016, 10, 1; 8-16
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Sentencing System in the Albanian Criminal Code and the Demand for Special Tretament of Juveniles
Autorzy:
Xhafo, Jola
Powiązania:
https://bibliotekanauki.pl/articles/1035875.pdf
Data publikacji:
2012
Wydawca:
Academicus. International Scientific Journal publishing house
Tematy:
Sentencing system
Sentence of imprisonment
Special treatment
Alternative measures
Educational measures
Opis:
Juveniles are subject to a cognitive process and growth, where the physical, intellectual, emotional and personality are still in phase of development phase. As a result, they enjoy a special status which arises the demand for their specialized treatment. The status as a minor in criminal matters raises the need to create a system consisting of different rules, which should take into consideration the physical and psychological peculiarities of the child and his educational needs. This system should be oriented towards the goal of juvenile education, rehabilitation and development, goal which can be successfully implemented only if it is reflected in the nature and types of sanctions applied to juveniles. In the application of sanctions it should be taken into consideration the need for education, assistance and welfare of the juvenile. Prison sentence and other similar measures should be considered as a last resort and used in order to reduce only when other forms of treatment do not comply with the personality of the offender and the seriousness of the offense. Priority should be given to educational and non-institutional measures. These requirements impose the necessity of legal interventions in the system of sanctions to address the needs for special treatment in accordance with the personality of the children and their individual needs for education. This paper aims at a critical analysis of the sentencing system provided in the Criminal Code, in the focus of the standards set by the international instruments which safeguard in a special manner the juvenile as a criminal offender. Through the analysis of legal provisions as well as referring to the juridical doctrine and court jurisprudence, there will be evidenced some issues related to the special treatment of juvenile criminal offenders in the field of the system of sentencing. After a detailed analysis, there will be provided conclusions and concrete recommendations on the current stage of the sentencing system, its’ compliance with the need for special treatment of juvenile criminal offenders, the need for improvement as well as the concrete legal initiatives to be adopted.
Źródło:
Academicus International Scientific Journal; 2012, 06; 47-61
2079-3715
2309-1088
Pojawia się w:
Academicus International Scientific Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Specifics personalized approach in the analysis of medical information
Autorzy:
Melnykova, N.
Marikutsa, O.
Powiązania:
https://bibliotekanauki.pl/articles/411025.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Oddział w Lublinie PAN
Tematy:
decision support system
data formalization
therapeutic treatment schemes
personalized of data
Opis:
In this article suggest some new approaches to solving the problems of medical data analysis and their personalization. To accomplish this was proposed to create a decision support system to the execution of sequence stages of analysis of patient's data. The main stages of development and design of decision support systems that enable to make decomposition of control process and describe the relationship between input and output control flows. Applying the theory of decision trees during construction of decision trees of decision support system is due to the formation of a sequence of questions asked by the doctor when searching an individual approach when choosing a treatment. Decision tree creates a hierarchical structure of rules. This approach allows you to present the logic of sequence issues by doctor in solving the medical problem history and it makes possible to simulate decision making process by physician when selecting treatment scheme. Search the target value of output of decision medical support system makes it possible to select top of graph system that is located with more probability on the best way to the target. Important step in addressing the process of personalizing treatment schemes is estimated function that is based on Bayes theorem. Weight of occurrence next event corresponds to the highest value of the posterior probability of occurrence of the next state, given the time-dependent input parameters. Proposed improved method of decision-making for personalization standard schemes by modifying the method of decision-making based on decision trees considering relationship between the input parameters and evaluation function and result of its works is a personalized therapeutic scheme of treatment. It analyzed the quantitative results of applying the proposed method and existing for determining personalized schemes.
Źródło:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes; 2016, 5, 2; 113-120
2084-5715
Pojawia się w:
ECONTECHMOD : An International Quarterly Journal on Economics of Technology and Modelling Processes
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie systemów informacji przestrzennej (GIS) w gospodarce osadami ściekowymi w aglomeracji górnośląskiej
Use of geographic information systems (GIS) in sewage sludge management in upper silesia metropolitan area
Autorzy:
Bielatowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/251382.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
system informacji przestrzennej
GIS
osad ściekowy
Śląsk
oczyszczanie ścieków
spatial information system
sludge
Silesia
wastewater treatment
Opis:
Osady ściekowe stanowią nieodłączny element oczyszczania ścieków. Zgodnie z Krajowym Planem Gospodarki Odpadami 2014 30% wytwarzanych osadów ściekowych ma być poddanych unieszkodliwieniu termicznemu do roku 2020. Zasadność użycia termicznych metod przekształcania osadów ściekowych jest uzależniona od szeregu czynników, przede wszystkim od wilgotności i własności paliwowych osadów, jak również od odległości dzielącej oczyszczalnie ścieków od zakładów. Celem pracy jest przedstawienie zastosowania Systemów Informacji Przestrzennej w zagospodarowaniu osadów ściekowych. W świetle planów budowy Zakładu Termicznego Przekształcania Odpadów Komunalnych dla Aglomeracji Górnośląskiej sprawdzono potencjalne lokalizacje pod kątem dostępności osadów ściekowych z pobliskich oczyszczalni. Do tego celu wykorzystano oprogramowanie ArcGIS by ESRI i wraz z dodatkiem Network Analyst przeprowadzono analizy sieciowe dostępności osadów ściekowych.
Sewage sludge is an integral part of wastewater treatment. According to the National Waste Management Plan 2014 (Krajowy Program Gospodarki Odpadami 2014) 30 % of sewage sludge produced is to be subjected to thermal disposal by 2020. The real use of thermal methods if sewage sludge treatment depends on the number of factors, in particular moisture content and fuel characteristics of sewage sludge and also the distance between sewage treatment plants and incineration plant. The aim of the study is to present the usage of Geographic Information Systems in sewage sludge management. In the light of plans to build a municipal solid waste incineration plant for Upper Silesian Metropolitan Area there were checked nearby sewage treatment plants for the availability of sewage sludge. For this purpose there was used ArcGIS by ESRI software with Network Analyst extension for which there were generated service areas of sewage sludge availability
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 145-150, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Orthonormal basis function fuzzy systems for biological wastewater treatment processes modeling
Autorzy:
Chaibakhsh, A.
Chaibakhsh, N.
Abbasi, M.
Norouzi, A.
Powiązania:
https://bibliotekanauki.pl/articles/91632.pdf
Data publikacji:
2012
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
fuzzy model
fuzzy system
orthonormal basis functions
OBF
treatment process
Laguerre filters
Opis:
In this paper, fuzzy models with orthonormal basis functions (OBF) framework are employed for modeling the nonlinear dynamics of biological treatment processes. These models are consisting of a linear part describing the system dynamics (Laguerre filters) followed by a non-linear static part (fuzzy system). The training procedure contains of two main steps: 1) obtaining the optimum time-scale and the order of truncated Laguerre network as the linear part and 2) defining membership functions, corresponding rules and adjusting the consequent parameters of fuzzy system as the nonlinear part. A comparison between the responses of the developed model and the original plant was performed in order to validate the accuracy of the developed model.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2012, 2, 4; 343-356
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The State of Water and Wastewater Management in the Municipalities of the Roztocze National Park
Autorzy:
Jóźwiakowski, K.
Podbrożna, D.
Kopczacka, K.
Jaguś, M.
Marzec, M.
Listosz, A.
Pochwatka, P.
Kowalczyk-Juśko, A.
Malik, A.
Powiązania:
https://bibliotekanauki.pl/articles/123660.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipality
water supply
sewage system
sewage treatment plant
septic tank
national park
Opis:
The aim of this paper is to present the current state of water and sewage management in the communes where the Roztocze National Park (RNP) is located. The park is located in Lubelskie voivodship, in the territory of four communes: Zamość, Zwierzyniec, Adamów and Józefów, while its buffer zone is located in the communes of Krasnobród, Tereszpol and Szczebrzeszyn. The paper uses data from surveys conducted in these municipalities in 2016. On average, 68.9% of the population used the water supply system in the municipalities surveyed, while 33.4% of the inhabitants had the possibility of discharging sewage to the sewerage system. In the area of the communes, there are 10 collective, mechanical and biological wastewater treatment plants with a capacity exceeding 5 m3·d-1. The households which are not connected to the sewage network discharge wastewater mainly to non-return tanks. Four out of the seven surveyed communities had 64 domestic sewage treatment plants, including 60 systems with infiltration drainage, which do not ensure high efficiency of removing pollution and may even contribute to the degradation of groundwater quality. In order to solve the existing problems in the area of sewage and water management occurring in the communes where the Roztocze National Park is located, it is necessary to further develop collective sewage systems and equip the areas with dispersed buildings with highly efficient, residential sewage treatment plants, e.g. constructed wetlands.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 255-262
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operational problems of constructed wetland for landfill leachate treatment: case study
Problemy z eksploatacją systemów hydrofitowych dooczyszczania odcieków ze składowiska: studium przypadku
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/401274.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
system hydrofitowy
odciek ze składowiska
zatykanie się
treatment wetland
landfill leachate
clogging
Opis:
In the paper the quality fluctuations of leachate from municipal landfill in Gdansk (Poland) over the last 5 years and evaluation of a wetland system designed for treatment of the leachate are discussed. The research has been conducted during the 5 years period. The constructed wetland for leachate treatment, consisting of 2 horizontal subsurface flow reed beds, working in parallel was built in 2001. In the period 2005-06 it underwent modernization due to unsatisfactory treatment results caused by clogging of the beds. The treatment effectiveness after modernization is satisfactory. The effluent from bed I met Polish outflow standards, while in the effluent from bed II COD, total N and TSS exceeded the required concentrations. In spite of this, pre-treatment of leachate (iron removal) should be quickly introduced to protect the system against the repetition of clogging problems.
Opisane w artykule badania prowadzono w okresie pięciu lat. System hydrofitowy zbudowany w 2001 roku do oczyszczania odcieków ze składowiska składa się z dwóch poziomych złóż o przepływie podpowierzchniowym, w układzie równoległym. W 2005-2006 roku wykonano modernizację układu ze względu na problem z zatykaniem się złóż. Efektywność oczyszczania po modernizacji jest zadowalająca, odpływ ze złoża I spełnia polskie normy, natomiast w przypadku złoża II zaobserwowano przekroczenia ChZT i zawiesiny ogólnej. W celu uniknięcia zatykania się złóż należy zastosować wstępne oczyszczanie odcieków.
Źródło:
Inżynieria Ekologiczna; 2011, 25; 202-210
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ obróbki termicznej na zmiany parametrów barwy na przykładzie marchwi
Influence of heat treatment on carrot colour parameters
Autorzy:
Biller, E.
Wierzbicka, A.
Półtorak, A.
Powiązania:
https://bibliotekanauki.pl/articles/290456.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
barwa
system L*a*b*
marchew
korzeń
obróbka termiczna
L*a*b* system
carrot
root
heat treatment
Opis:
Celem pracy była ocena wpływu wybranych typów obróbki termicznej na zmiany barwy ogrzewanego surowca na przykładzie marchwi. Obróbce poddano marchew rozdrobnioną na kostkę wykorzystując piec konwekcyjno-parowy i steamer oraz różny czas operacji – odpowiednio dla obydwu urządzeń: 5, 10, 15 i 20 minut oraz 4, 6, 8 i 10 minut. Na skutek obróbki termicznej zanotowano zmiany w badanych wyróżnikach barwy (L*a*b*). Wartości poszczególnych parametrów sukcesywnie zmniejszały się.
The aim of this work was the effect of selected kinds the heat treatment on the colour changes in the heated raw materials. Carrots was taken to this investigation. Carrot cubes were processed in the convection-steam oven and steamer, with different operation times, properly for both devices: 10, 15, 20 min and 4, 6, 8, 10 minutes. In consequence of the heat treatment change of colour attributes was noted, in investigated samples. Values of the individual colour parameters decrease during lengthen of the heat process.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 9, 9; 7-12
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sustainable Wastewater Treatment Solutions for Rural Communities’: Public (Centralized) or Individual (On-Site) – Case Study
Zrównoważony rozwój przy rozwiązaniach oczyszczania ścieków na terenach wiejskich: publiczne (centralne) czy indywidualne (lokalne) - case study
Autorzy:
Boguniewicz-Zabłocka, Joanna
Capodaglio, Andrea G.
Powiązania:
https://bibliotekanauki.pl/articles/435034.pdf
Data publikacji:
2017-12-31
Wydawca:
Uniwersytet Opolski
Tematy:
wastewater treatment plant
sustainability criteria
local sanitation system
oczyszczalnie ścieków
kryteria zrównoważonego rozwoju
lokalny system unieszkodliwiania ścieków
Opis:
The implementation of Water Framework Directive, speaking about the need to achieve good water status, and thus the corresponding sewage treatment caused the problem of waste water management has become a very important starting from the municipal level, through the national and the European ending. Sustainability, although not explicitly mentioned in the relevant EU or national legislation, it is key to implement wastewater systems. Their main objectives are to protect and promote human health by providing a clean environment, and breaking the cycle of disease. In this paper sustainability of wastewater collection and treatment options in the rural communities’ in Poland, are discussed in the context of recent infrastructure investments. The paper presents an attempt to evaluate the implemented solutions for wastewater management in rural areas considering sustainable development criteria. Advantages and disadvantages of proposed system has been analysed with the focus to the question of selecting the right strategy that would fulfil both population and environmental needs.
Wdrożenie Ramowej Dyrektywy Wodnej, mówiącej o potrzebie osiągnięcia dobrego stanu wód, i w związku z tym odpowiedniego oczyszczenie ścieków spowodowało, iż problem gospodarki ściekowej stał się bardzo ważny poczynając od szczebla gminnego, poprzez narodowy na europejskim kończąc. Zrównoważony rozwój choć nie został wyraźnie wymieniony w odnośnym prawodawstwie krajowym i europejskim jest kluczowy dla wdrażania programów oczyszczania ścieków. Głównym celem jest ochrona i promowanie zdrowia ludzi poprzez zapewnienie czystego środowiska. Zrównoważony rozwój przy wyborze systemów oczyszczania ścieków na terenach wiejskich w Polsce omówiono w kontekście niedawnych inwestycji infrastrukturalnych. W artykule przedstawiono próbę oceny wdrożonych rozwiązań dla gospodarki ściekowej na terenie wiejskim biorąc pod uwagę kryteria zrównoważonego rozwoju. Wady i zalety proponowanych systemów oczyszczania ścieków analizowano z naciskiem na kwestie wyboru właściwego systemu, który zaspokoi potrzeby ludności i nie wpłynie negatywnie na środowisko.
Źródło:
Economic and Environmental Studies; 2017, 17, 44; 1103-1119
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined Ozonation - Nanofiltration for Mycoestrogens Removal from Water
Ozonowanie-nanofiltracja w usuwaniu mykoestrogenów z wody
Autorzy:
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/204556.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mykoestrogeny
mikrozanieczyszczenia organiczne
ozonowanie
nanofiltracja
system zintegrowany
uzdatnianie wody
mycoestrogens
organic micropollutants
ozonation
nanofiltration
integrated system
water treatment
Opis:
The paper describes the effectiveness of mycoestrogen removal in an integrated ozonation - nanofiltration system for water treatment. The results were compared to those obtained for ozonation and nanofiltration carried out as single processes. It has been found that the effectiveness of mycoestrogen removal in the integrated system was higher than that observed for single ozonation. During ozonation, the removal of micropollutants was affected by the dose of an oxidizing agent and type of treated water. As far as nanofiltration is concerned, its effectiveness both in the integrated system and as a single process was similar. Nevertheless, it is advisable to precede nanofiltration with ozonation because of membrane efficiency.
W pracy przedstawiono efektywność usuwania mykoestrogenów w zintegrowanym układzie oczyszczania wody ozonowanie - nanofiltracja. Wyniki badań porównano do wyników uzyskanych podczas ozonowania i nanofiltracji, które realizowane były jako procesy pojedyncze. Określono, że efektywność usuwania mykoestrogenów w układzie zintegrowanym jest wyższa niż obserwowana w pojedynczym procesie ozonowania. W przypadku ozonowania na usuwanie mikrozanieczyszczeń ma wpływ dawka utleniacza i rodzaj oczyszczanej wody. Z kolei efektywność nanofiltracji realizowanej jako proces pojedynczy i w układzie zintegrowanym pod kątem usuwania mykoestrogenów była zbliżona. Jednak biorąc pod uwagę wydajność membrany korzystniej jest proces nanofiltracji poprzedzić procesem ozonowania wody.
Źródło:
Archives of Environmental Protection; 2012, 38, 2; 103-109
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring, early warning and sustainable management system for Lodz wastewater treatment plant as a water protection tool
Autorzy:
Sakson, Grażyna
Brzezińska, Agnieszka
Kowalski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/105052.pdf
Data publikacji:
2019
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
sewer system
sewage treatment
water protection
predictive model
toxicity
system ściekowy
oczyszczanie ścieków
ochrona wód
model predykcyjny
toksyczność
Opis:
Municipal wastewater treatment plants are exposed to the inflow of toxic substances, which may hamper or even preclude their proper functioning, especially of the biological part. In the case of combined or hybrid sewer systems, additionally, in wet weather, there may appear a rapid inflow of a mixture of domestic and industrial sewage, and stormwater in an amount exceeding the capacity of the devices, causing the need to discharge parts of not fully treated wastewater through the bypass channel, which may reduce overall treatment effects. In such situations, the receivers are exposed to an inflow of increased amounts of pollutants, which on the one hand causes a threat to the aquatic environment, on the other, may result in administrative fines for the treatment plant resulting from non-compliance with the conditions of the water permit, as well as costs of removing the effects of failure. The article presents the concept of a monitoring, early warning and sustainable management system for the Lodz wastewater treatment plant, which will allow minimizing pollutant emissions to the aquatic environment. The system will be based on data from the municipal pluviometer network, measurement of flows in combines sewer overflows and newly built sewage quality monitoring stations equipped with on-line probes. The resulting data will allow to predict quantity and quality of inflow to the treatment plant, which will allow for an early warning about the dangers. In consequence decision-making to improve the safety of its operation will be possible.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2019, 66, 3; 5-16
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozwiązania techniczne kanalizacji sanitarnej z zastosowaniem oczyszczalni przydomowych
Technical solutions of sanitary sewerage with the use of domestic sewage treatment plants
Autorzy:
Eymontt, A.
Gutry, P.
Powiązania:
https://bibliotekanauki.pl/articles/239611.pdf
Data publikacji:
2010
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
kanalizacja
metoda AHP
oczyszczalnia przydomowa
sewerage system
AHP method
domestic sewage treatment plants
Opis:
Zastosowanie i wdrażanie techniki sanitarnej na terenach wiejskich stanowi wydzielony zespół zagadnień z całości tej techniki i wchodzi w zakres techniki rolniczej oraz inżynierii środowiska. Odprowadzanie i oczyszczanie ścieków bytowych z gospodarstw na wsiach o zabudowie rozproszonej lub średnio zwartej o zróżnicowanych warunkach gruntowo-wodnych i terenowych wymaga stosowania technik innych niż w miastach lub zwartych osiedlach, uwzględniających ograniczenia środowiskowe, ekonomiczne, społeczne oraz wynikające z istniejącej na wsiach infrastruktury. Dlatego wprowadzane takie są innowacyjne technologie odprowadzania ścieków, jak: kanalizacja ciśnieniowa z pompami niskociśnieniowymi i wysokociśnieniowymi, podciśnieniowa, mieszana, małośrednicowa, oraz kanalizacja tradycyjna, grawitacyjna, a w zabudowie kolonijnej - oczyszczalnie przydomowe. Przed uruchomieniem procesu projektowania rozwiązań systemowych dla gmin lub wsi, należy przeprowadzić analizę rozwiązań najkorzystniejszych w danych warunkach. W praktyce często są wybierane przez wójtów, przy współudziale projektantów i producentów urządzeń, rozwiązania nieuzasadnione merytorycznie i ekonomicznie, preferujące jeden z systemów. W wielu przypadkach są to rozwiązania najtańsze w realizacji, ale trudne w eksploatacji, jak oczyszczalnie przydomowe działające w technologii niskoobciążonego osadu czynnego. W IBMER (obecnie Instytut Technologiczno-Przyrodniczy) przebadano kilka rodzajów oczyszczalni oraz oceniono ich skuteczność. Najlepsze wyniki oczyszczania uzyskano w oczyszczalniach gruntowo-roślinnych ze stawem stabilizującym. Jednocześnie są prowadzone badania istniejących i nowych rozwiązań systemów odprowadzania ścieków, w tym kanalizacji małośrednicowej, działającej na zasadzie kolejnych przelewów ścieków, co jest przedmiotem patentu. W trakcie badań będzie można szczegółowo scharakteryzować zarówno cechy systemów kanalizacyjnych, jak i jakość zastosowanych w nich rozwiązań.
Application and implementation of the sanitary engineering on rural areas create a separated group of issues within this technical knowledge, closely connected with agricultural and environmental engineering. Disposal and purification of domestic sewage from the farms in villages of scattered or medium-compact housing, of differentiated ground-water and terrain conditions, need the application of techniques other than in the towns or compacted settlements; the environmental, economic, social limitations, as well as those connected with actually existing rural infrastructure, have to be taken into account. For the above reasons the innovative technologies of sewage disposal are introduced, such as pressurized sewage system with low- and high-pressure pumps, underpressure, mixed and small-diameter systems and traditional gravitation sewerage. Domestic sewage treatment plants are provided for dispersed development. Beginning of designing systemic solutions for the communes or villages ought to be preceded by the analyses of the solutions most convenient to given circumstances. Practically, the chiefs of communes, at participation of equipment designers and producers, often select the solutions essentially and economically groundless, with the preference to one system over the others. In many cases the solutions having been selected are the cheapest in realization, but difficult in operation, like the domestic sewage treatment plants working in technology of low-laden active sediment. The Institute of Technology and Life Sciences (formerly IBMER) tested few kinds of sewage treatment plants and assessed their usability. Best results of sewage purification were obtained in constructed wetlands (ground-vegetation system with a stabilization pond). There are also investigated existing and new solutions of sewage disposal, including small-diameter sewerage based on the rule of succeeding sewage overflow (having been patented). In the course of investigations it will be possible to characterize in details both, the properties of sewage disposal systems and the functionality of applied technical solutions.
Źródło:
Problemy Inżynierii Rolniczej; 2010, R. 18, nr 4, 4; 141-154
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Eksploatacja wodociągu wrocławskiego w aspekcie niezawodności zakładów uzdatniania wody
Operation of the Waterworks of Wrocław: Reliability of the Water Treatment Plants
Autorzy:
Zimoch, I.
Binda, B.
Powiązania:
https://bibliotekanauki.pl/articles/236374.pdf
Data publikacji:
2003
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
niezawodność
system zaopatrzenia w wodę
ujęcie wody
zakłady uzdatniania wody
reliability
water supply system
water intake
water treatment plant
Opis:
W ostatnich latach nastąpił wyraźny postęp w stosowaniu teorii niezawodności w branży wodociągowej. Na świecie ważniejsze systemy zaopatrzenia w wodę projektuje się i ocenia przy wykorzystaniu osiągnięć tej teorii. W pracy zaprezentowano praktyczne wykorzystanie modelu do oceny probabilistycznej technicznego funkcjonowania przedsiębiorstwa wodociągowego, na przykładzie zakładów uzdatniania wody "Mokry Dwór" i "Na Grobli" we Wrocławiu. Ocena ta, w oparciu o rzeczywiste dane eksploatacyjne z lat 2001-2002 oraz dane literaturowe, obejmuje określenie wartości estymatorów wskaźników niezawodności poszczególnych zakładów uzdatniania wody oraz stacjonarnego wskaźnika gotowości podsystemu dostawy wody dla Wrocławia.
In recent years, the application of the reliability theory to the operation of water supply systems has become increasingly frequent all over the world, where major systems are designed and assessed in terms of this theory. In the present paper a probabilistic model is described. The model was used to evaluate the technical operation of two water treatment plants, Mokry Dwór and Na Grobli, which are part of the water supply system for the city of Wrocław and serve a population of about 700,000 inhabitants. Based on real operating data from the years 2001 and 2002, as well as literature reports, the evaluation includes the reliability index estimators for particular water treatment facilities and the stationary availability index of the water intake subsystem for the city of Wrocław.
Źródło:
Ochrona Środowiska; 2003, R. 25, nr 3, 3; 35-39
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja technologii oczyszczania ścieków w aspekcie rozbudowy systemu kanalizacyjnego
Conditioning of wastewater treatment technology optimization of sewage treatment in terms of expansion of the sewerage system
Autorzy:
Zdebik, D.
Korczak, K.
Powiązania:
https://bibliotekanauki.pl/articles/340774.pdf
Data publikacji:
2010
Wydawca:
Główny Instytut Górnictwa
Tematy:
oczyszczanie ścieków
optymalizacja
system kanalizacyjny
modernizacja
obciążenie oczyszczalni
treatment of wastewaters
optimization
sewage system
burden of sewage works
modernization
Opis:
Procesy inwestycyjne, związane z rozbudową systemu kanalizacyjnego, mają wpływ na zmianę parametrów ścieków dopływających do oczyszczalni. Zwiększenie obciążenia układu technologicznego oczyszczalni dodatkowym ładunkiem zanieczyszczeń skutkuje koniecznością dostosowania go do zmienionych warunków, przez działania inwestycyjne bądź też optymalizację technologii w celu jej intensyfikacji. Pod tym kątem w artykule oceniono trzy oczyszczalnie ścieków, pracujące w warunkach przebudowy i rozbudowy systemu kanalizacyjnego. Przedstawiono obciążenie oczyszczalni ładunkiem zanieczyszczeń oraz scharakteryzowano podatność ścieków w procesie ich biologicznego oczyszczania. Dokonano prognozy dopływu ścieków z terenów objętych inwestycją i określono ich wpływ na obecnie pracujące instalacje. Przedstawiono także ocenę planowanej modernizacji oczyszczalni w zlewni.
Led investment processes related to expansion of sewage system have influence on a change of parameters of sewage floating to sewage treatment plant. An increase of technological system of sewage treatment plant burden with additional pollutant load cause that adjustment of technological system through investment activities or optimisation of technology towards its intensification is the necessity. An analysis was carried out in sewage treatment plant with throughtput from 15 000 to 100 000 PE, with reference to identification of current sewage treatment process and changes, which an additional pollutant load evokes. An comparative analysis includes 3 sewage treatment plants working in the condition of rebuilding and expansion of sewage system. Sewage treatment plant burden with pollutant load was presented and susceptibility of sewage in the biological sewage treatment process was characterised. Forecast of sewage inflow from investment area was carried out and their influence on currently working facilities was determined. An assessment of planned investment purposes in the sewage treatment planfs catchment in the aspect of its adjustment to increased pollutant load inflow as an effect of realization of infrastructure investments co - financed by European Union funds was also presented.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2010, 1; 73-89
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of medical data as a way of speeding up development of algorithms for a system for estimation of patients health
Symulacja danych medycznych jako sposób przyspieszenia rozwoju algorytmów systemu oceny stanu pacjenta
Autorzy:
Wenerski, M.
Tylman, W.
Napieralski, A.
Trafidło, T.
Waszyrowski, T.
Tomala, R.
Marciniak, P.
Kotas, R.
Kamiński, M.
Kulesza, Z.
Powiązania:
https://bibliotekanauki.pl/articles/322516.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
choroby układu krążenia
hospitalizacja
system wspomagania decyzji
sztuczna inteligencja
MEWS
cardiovascular diseases
hospital treatment
decision support system
artificial intelligence
Opis:
W artykule przedstawiono system wspomagania decyzji odnośnie do oceny stanu ogólnego pacjenta, ze szczególnym naciskiem położonym na choroby układu krążenia i układu oddechowego. Działanie tego systemu jest oparte na danych wejściowych ze standardowego monitora funkcji życiowych (w fazie rozwoju algorytmów dane są również symulowane). Sygnały są przetwarzane i analizowane za pomocą algorytmów opartych, przede wszystkim, na sieciach Bayesa. System na wyjściu powinien generować informację na temat wykrytych problemów, przyszłych zagrożeń, przyczyn pogorszenia zdrowia i propozycji dalszego leczenia.
This paper presents decision support system for estimation of patient's general state, with particular stress laid on cardiovascular and pulmonary diseases. It works in conjunction with a standard medical monitor, which provides asset of input signals (for development stage signals are also simulated). The signals are preprocessed and analysed by a set of algorithms, the core of which is based on Bayesian networks. As an output the system should give information about detected problems, eventual future threats, possible causes and suggestions for further treatment.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2014, 74; 631-639
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wielopoziomowy system sterowania stężeniem tlenu i wyznaczania trajektorii zadanej stężenia tlenu w biologicznej oczyszczalni ścieków
Multilevel control system for dissolved oxygen control and determining the set point trajectory of dissolved oxygen in a biological wastewater treatment plant
Autorzy:
Piotrowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/276244.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
napowietrzanie ścieków
oczyszczalnia ścieków
SBR
stężenie tlenu
wielopoziomowy system sterowania
aeration
wastewater treatment plant
dissolved oxygen
multilevel control system
Opis:
Napowietrzanie ścieków jest jednym z najważniejszych i najdroższych procesów w oczyszczalni ścieków. Stężenie tlenu jest natomiast głównym parametrem wpływającym na efektywność zachodzenia procesów biologicznych w oczyszczalni ścieków. W artykule przedstawiono wielopoziomowy nieliniowy system sterowania stężeniem tlenu i wyznaczania trajektorii zadanej tej wielkości. W testach symulacyjnych pokazano wyniki sterowania dla oczyszczalni ścieków typu SBR.
Aeration of wastewater is one of the most important and expensive process in a wastewater treatment plant. Dissolved oxygen concentration is the main parameter influencing the effectiveness of biological processes in wastewater treatment plant. In the paper, a multilevel nonlinear control system for dissolved oxygen control and determining the set point trajectory of dissolved oxygen was designed. The control results for the SBR wastewater treatment plant were presented in simulation tests.
Źródło:
Pomiary Automatyka Robotyka; 2018, 22, 4; 19-23
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic risk assessment method : a proposal for assessing risk in water supply system
Metoda dynamicznego szacowania ryzyka : propozycja oceny ryzyka w systemie zaopatrzenia wody
Autorzy:
Fortmann-Roe, S.
Iwanejko, R.
Wójcik, W.
Powiązania:
https://bibliotekanauki.pl/articles/205339.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
risk
system dynamics
water treatment
waterborne pathogens
ryzyko
dynamika układu
uzdatnianie wody
patogeny wodorozcieńczalne
Opis:
System Dynamics is methodology for modeling and analyzing complex systems. Such systems can be characterized by interconnectedness and feedback. Applying risk assessment to the results of System Dynamics models is a challenge. Though in some cases the resulting time series data generated by a simulation may appear approximately random at a specific scale, there is often a high-degree of auto-correlation within the data series due to the deterministic nature of generation and feedback loops inherent in the system. This paper presents proposed Dynamic Risk Assessment Method (DRAM) that allows for the estimation of risk for system dynamics data series that appear to be approximately random. DRAM is based on standard risk assessment methods and is simple both to calculate and apply. In this article, the proposed method is applied to determine the risk connected with hypothetical costs of illness stemming from water supply system contamination with Cryptosporidium.
Dynamika Systemów jest metodologią modelowania i analizy złożonych systemów. Taki złożony system może być charakteryzowany przez wzajemne proste połączenia elementów oraz istniejące sprzężenia zwrotne. Przeprowadzenie oceny ryzyka przy modelowaniu Systemów Dynamicznych jest trudnym wyzwaniem. Chociaż w niektórych przypadkach, uzyskane za pomocą symulacji serie wyników mogą się wydawać przypadkowe, to jednak często istnieje wysoki stopień autokorelacji między tymi seriami wynikający z istnienia powiązań zwrotnych w systemie. Artykuł przedstawia propozycje Metody Dynamicznego Szacowania Ryzyka (MDSR), która pozwala oceniać ryzyko związane z hipotetycznymi kosztami zachorowań wywołanymi skażeniem systemu zaopatrzenia w wodę przez Cryptosporidium.
Źródło:
Archives of Environmental Protection; 2015, 41, 2; 36-40
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surgical Management of Genitourinary Tuberculosis: our Experience and review of literature
Autorzy:
Mittal, Ankur
Ranjan, Satish
Narain, Tushar
Panwar, Vikas
Powiązania:
https://bibliotekanauki.pl/articles/1391814.pdf
Data publikacji:
2020
Wydawca:
Index Copernicus International
Tematy:
antitubercular treatment (ATT)
extrapulmonary tuberculosis (EPTB)
genitourinary system (GUS)
genitourinary tuberculosis (GUTB)
tuberculosis (TB)
Opis:
Background: Genitourinary tuberculosis is one of the most common forms of extra-pulmonary tuberculosis. Owing to a myriad of clinical presentations and discrepancies in the diagnostic modalities, patients usually present late, which results in a high number of them requiring surgical intervention. The present study aims to retrospectively analyze the role of surgery in genitourinary tuberculosis. Patients and method: All patients diagnosed with genitourinary tuberculosis at our centre between October 2017 and September 2019 were included in the study. The mode of presentation, duration of symptoms, investigations performed, treatment received, and follow-up were studied. Results: Out of 25 patients diagnosed with genitourinary tuberculosis (GUTB), there were 15 (60%) males and 10 (40%) females. The mean age of presentation was 40.84 years. Nineteen (76%) patients underwent surgical intervention, and many patients required more than one surgical procedure. A reconstructive procedure was carried out in seven patients. At a median follow-up of 12 months, all patients did well, showing no relapse. Conclusion: Surgery, along with antitubercular treatment, is the key to the management of GUTB presenting with structural damage. However, surgery can be ablative or reconstructive, depending on various factors discussed in the present study. This preserves or restores the optimal function of the genitourinary system affected by the mycobacterium bacilli.
Źródło:
Polish Journal of Surgery; 2020, 92, 6; 1-6
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lokalizacji oczyszczalni na temperaturę dopływających do niej ścieków
Influence of treatment plant location on temperature of inflowing sewage
Autorzy:
Kaczor, G.
Bugajski, P.
Chmielowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/101199.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
oczyszczalnia ścieków
ścieki
kanalizacja
temperatura ścieków
wastewater treatment plant
wastewater
sewage system
wastewater temperature
Opis:
Celem przeprowadzonych badań było uzyskanie wiedzy, jak umiejscowienie oczyszczalni względem zlewni kanalizacyjnej wpływa na temperaturę dopływających do niej ścieków. Analizą objęto cztery systemy kanalizacyjne, różniące się długością kolektora tranzytowego pomiędzy oczyszczalnią a zabudowaniami mieszkalnymi, w których wytwarzane były ścieki bytowe. W badanych systemach kanalizacyjnych ścieki odprowadzane były do oczyszczalni o przepustowości hydraulicznej od 100 do 300 m3·d-1, charakteryzujących się liczbą RLM nie większą niż 2000. Pomiary temperatury ścieków odpływających z kanalizacji oraz powietrza atmosferycznego, w analizowanym roku 2012, prowadzono w sposób ciągły, z interwałem 1 godzinnym, za pomocą czujników rezystancyjnych połączonych z rejestratorami danych. Przeprowadzone badania wykazały, że odległość oczyszczalni od zlewni kanalizacyjnej wywiera istotny wpływ na temperaturę ścieków odpływających z sieci kanalizacyjnej. W okresie zimowym średnia dobowa temperatura ścieków odpływających z kolektorów tranzytowych o długości od 300 do 600 m była niższa nawet o blisko 3ºC, natomiast w okresie letnim aż o 8ºC, w porównaniu do kolektorów tranzytowych o długości nieprzekraczającej 10 m. Wykazano ponadto, że na temperaturę ścieków dopływających do oczyszczalni, oprócz długości kolektora tranzytowego, istotnie wpływa także natężenie przepływu ścieków. Przy wzroście natężenia odpływu ścieków z kanalizacji o 100%, ich temperatura może wzrosnąć w okresie zimowym o 1ºC, natomiast w letnim o 3ºC. W przypadku sieci kanalizacyjnych zakończonych długimi kolektorami tranzytowymi, niekorzystnemu skróceniu ulega czas trwania temperatury ścieków optymalnej w aspekcie usuwania związków biogennych, a przy tym jednocześnie wydłuża się czas trwania temperatury ścieków niekorzystnej dla ich biologicznego oczyszczania.
The aim of the research was to get the expertise, how location of wastewater treatment plant to basin of sewage system influences the temperature of inflowing wastewater. The analysis included four sewage systems, which are different for the sake of length of transit canal between treatment plant and residential buildings, in which domestic sewage was produced. In analysed systems sewage flew into the treatment plants with hydraulic capacity range from 100 to 300 m3·d-1, and with population equivalent less than 2000. Measurements of temperature of air and wastewater outflowing from sewage system, in analysed year 2012, were conducted continuously, with 1 hour interval, with use resistance sensors connected with data recorder. The research showed, that the distance of treatment plant to basin of sewage system has a significant impact on wastewater temperature outflowing from sewage system. In winter period mean daily wastewater temperature outflowing from transit manifolds with length from 300 to 600 m was lower even about 3ºC, but in summer period up to 8ºC, in comparison to transit manifolds with length less than 10 m. Moreover, it was proved that, apart from length of transit manifold, also intensity of wastewater flow has a significant impact on wastewater temperature flowing into the treatment plant. With increase of intensity of wastewater flow about 100%, its temperature can increase in winter period about 1ºC, and about 3ºC in summer period. In case of sewage systems ended with long transit manifold, the duration time of optimal sewage temperature in terms of biogenic compounds removal is unfavourable reduced, and at the same time the duration time of wastewater temperature unfavourable for its biological treatment is extended.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, II/2; 615-626
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies