Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transients overvoltage" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Modeling transients in MV resonantly grounded industrial grid during single line to ground faults
Autorzy:
Warecki, Jurij
Gajdzica, Michał
Powiązania:
https://bibliotekanauki.pl/articles/377060.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical grid
grounding methods
transients overvoltage
transient intermittent faults
Opis:
Medium voltage distribution power grids mostly operate with ungrounded neutral points of transformer. The philosophy about these power supply systems based on the assumption that the electrical grid is more reliable. However the practice of operation showed that currents of single phase or multiple faults to ground depend mostly on the earth capacitances of cables connected to power grid and configuration and structure in relation to the main substation buses. Moreover, this kind of arcing ground faults on the ungrounded system causes transient overvoltages several times than nominal value. In the consequence, it may be dangerous for the electrical devices connected to the power system. The article focuses on the transient impact the equipment insulation due to faults in the middle voltage industrial grid with adjustable speed drives. The examination results of transient voltages across the system was presented. The Matlab/ Simulink Software was used to modeling system behavior during intermittent faults.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 98; 65-75
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transients under energizing multiple power filter circuits
Autorzy:
Warecki, J.
Gajdzica, M.
Powiązania:
https://bibliotekanauki.pl/articles/97327.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
capacitor
reactor
harmonic filter
C–type filter
Static Var Compensator
transient overcurrent
transient overvoltage
dynamic overcurrent
dynamic overvoltage
switching transients
Opis:
The practice of operating reactive power compensation systems involving passive multiple filter circuits (FC) configured by single–tuned filters has shown, that it’s energizing can cause damage of the filter components. Impact of feasible FC configurations, including FC with a C–type filter, on switching overvoltages and overcurrents under the harmonic filters energizing were analyzed. Influence of the filters tuning on transient behavior has been shown. The transient analysis has been carried out by simulating of the FC within Matlab/Simulink software.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 89-100
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies