Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "tone audiometry" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Functional outcomes of tympanoplasty surgery
Autorzy:
Matuszewska, Izabela
Burduk, Paweł
Kaźmierczak, Wojciech
Janiak-Kiszka, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1398626.pdf
Data publikacji:
2016
Wydawca:
Index Copernicus International
Tematy:
chronic otitis media
Tympanoplasty
pure tone audiometry
Opis:
Objective: We reviewed functional outcomes of tympanoplasty. Study design: The results of tympanoplastic surgery are changing in time. We present late treatment outcomes among different types of tympanoplasty. Methods: Eighty-six patients who underwent tympanoplasty were enrolled in the study. The results of pure tone audiometry performed 7 days before, then at 3 months, 1 year, and 3 years after the surgery were assessed. Type II tympanoplasty involved implantation of a partial ossicular replacement prosthesis and type III tympanoplasty involved reconstruction with a total ossicular replacement prosthesis and the use of autogenous homogenous material. Statistical analysis was performed. Results: With all four types of tympanoplasty, hearing improvement was achieved at 3 months and 1 year after surgery based on the magnitude of the mean ABG reduction (p<0.001). In patients who underwent type I, type III, and type IV tympanoplasty, the ABG reduction at 3 years after surgery was maintained at the level reported at 3 months and 1 year after surgery (p<0.001). In patients who underwent type II tympanoplasty, however, the mean ABG value was increased at all tested frequencies (p<0.05). The mean ABG values reported 3 years after type II and type III tympanoplasty were similar. Conclusions: Based on the results over time, hearing improvement seems to be less durable after reconstruction with the partial ossicular replacement prosthesis procedure compared to the total ossicular replacement prosthesis procedure.
Źródło:
Polish Journal of Otolaryngology; 2016, 70, 6; 12-19
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Theoretical Predictions and Actual Hearing Threshold Levels in Workers Exposed to Ultrasonic Noise of Impulsive Character—A Pilot Study
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Śliwińska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/90926.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ultrasonic noise
noise measurements
pure-tone audiometry
hearing threshold levels
Opis:
Results of standard pure-tone audiom etry (PTA) were collected from 25 workers, mainly females, aged 23–58 years, exposed for 2–13 years to ultrasonic noise emitted by ultrasonic welders. Hearing tests were completed by evaluation of exposure to ultrasonic noise. The subjects’ actual audiometric hearing threshold levels (HTLs) were compared with theoretical predictions calculated according to ISO 1999:1990. In 60% of cases sound pressure levels in the 10–40 kHz 1/3-octave bands at workstands exceeded Polish exposure limits for ultrasonic noise. Our comparison of predicted and measured HTLs suggests that the ISO 1999:1990 method, intended for audible noise, might also make it possible to predict reliably permanent hearing loss (in the 2 000–6 000 Hz frequency range) after exposure to ultrasonic noise. No significant progress of hearing impairment (assessed using PTA) in the operators of ultrasonic welders was noted. Nevertheless, further studies on the hearing status of workers exposed to ultrasonic noise are needed.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 4; 409--418
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Meniere Disease p. 1. Diagnosis criteria, signs and symptoms of Meniere Disease (MD) – comment to updated guidelines and own experiences
Autorzy:
Niemczyk, Kazimierz
Pierchała, Katarzyna
Bartoszewicz, Robert
Jasińska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1399343.pdf
Data publikacji:
2019
Wydawca:
Index Copernicus International
Tematy:
hearing loss
inner ear
Meniere’s disease
tinnitus
tone audiometry
vertigo
Opis:
We present an overview of current diagnostic and therapeutic guidelines on Ménière’s disease. Over the last five years, four studies on this subject have been published. In 2015, five Societies including the Classification Committee of the Barany Society, Japan Society for Equilibrium Research, EAONO - European Academy of Otology and Neurotology, AAO-HNS - American Academy of Otorhinolaryngology - Head Neck Surgery, and Korean Balance Society have issued updated guidelines on the diagnosis and treatment of Ménière’s disease. Other multi-center publications have since been published as well such as the International consensus (ICON) on treatment of Ménière’s disease 2018, European Position Statement on Diagnosis, and Treatment of Meniere’s Disease, Diagnostic and therapeutic strategy in Ménière’s disease, Guidelines of the French Otorhinolaryngology - Head and Neck Surgery Society (SFORL) 2017. The above-listed recommendations include the most recent diagnostic advancements (e.g. inner ear MRI) and new electrophysiological tests, but also discuss other commonly used treatment modalities, result reporting and they take into account the quality of life of the patients following treatment. We present the main clinical challenges in managing Ménière’s disease, principles of diagnosis as well as the treatment introduced at our center. Finally, we discuss fundamental updates contained in the published papers.
Źródło:
Polski Przegląd Otorynolaryngologiczny; 2019, 8, 2; 12-17
2084-5308
2300-7338
Pojawia się w:
Polski Przegląd Otorynolaryngologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing status of people occupationally exposed to ultrasonic noise
Autorzy:
Dudarewicz, Adam
Zamojska-Daniszewska, Małgorzata
Zaborowski, Kamil
Pawlaczyk-Łuszczyńska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2084911.pdf
Data publikacji:
2022-06-08
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
noise
pure-tone audiometry
otoacoustic emissions
noise-induced hearing loss
ultrasonic noise
extended high-frequency audiometry
Opis:
ObjectivesThe aim of the study was to evaluate the hearing status of operators of low-frequency ultrasonic devices compared to employees exposed to audible noise at a similar A-weighted sound pressure level (SPL) but without ultrasonic components.Material and MethodsStandard pure-tone audiometry, extended high-frequency audiometry (EHFA), transient-evoked otoacoustic emissions (TEOAE), and distortion-product otoacoustic emissions (DPOAE), as well as questionnaire surveys were conducted among 148 subjects, aged 43.1±10.8 years, working as ultrasonic device operators for 18.7±10.6 years. Their exposure to noise within the ultrasonic and audible frequency range was also evaluated. The control group comprised 168 workers, adjusted according to gender, age (±2 years), tenure (±2 years), and the 8-hour daily noise exposure level (LEX,8h) of ±2 dB.ResultsThe ultrasonic device operators and the control group were exposed to audible noise at LEX,8h of 80.8±3.9 dB and 79.1±3.4, respectively. The Polish maximum admissible intensity (MAI) values for audible noise were exceeded in 16.8% of the ultrasonic device operators, while 91.2% of them were exposed to ultrasonic noise at SPL>MAI values. There were no significant differences between the groups in terms of the hearing threshold levels (HTLs) up to 3 kHz, while the ultrasonic device operators exhibited significantly higher (worse) HTLs, as compared to the control group, in the range of 4–14 kHz. The results of the DPOAE and TEOAE testing also indicated worse hearing among the ultrasonic device operators. However, the differences between the groups were more pronounced in the case of EHFA and DPOAEs.ConclusionsThe outcomes of all hearing tests consistently indicated worse hearing among the ultrasonic device operators as compared to the control group. Both EHFA and DPOAE seem to be useful tools for recognizing early signs of hearing loss among ultrasonic device operators.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 3; 309-325
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Ability in Orchestral Musicians
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Dudarewicz, A.
Zamojska, M.
Śliwińska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/177978.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
musicians
exposure to orchestral noise
hearing impairment
pure-tone audiometry
transient-evoked otoacoustic emissions
Opis:
Pure-tone audiometry (PTA) and transient-evoked otoacoustic emissions (TEOAEs) were determined in 57 classical orchestral musicians along with a questionnaire inquiry using a modified Amsterdam Inventory for Auditory Disability and Handicap ((m)AIADH). Data on musicians’ working experience and sound pressure levels produced by various groups of instruments were also collected. Measured hearing threshold levels (HTLs) were compared with the theoretical predictions calculated according to ISO 1999:1990. High frequency notched audiograms typical for noise-induced hearing loss were found in 28% of the subjects. PTA and TEOAE consistently showed a tendency toward better hearing in females vs. males, younger vs. older subjects, and lower- vs. higher-exposed to orchestral noise subjects. Audiometric HTLs were better than theoretical predictions in the frequency range of 2000–4000 Hz. The (m)AIADH scores indicated some hearing difficulties in relation to intelligibility in noisy environment in 26% of the players. Our results indicated a need to implement a hearing conservation program for this professional group.
Źródło:
Archives of Acoustics; 2010, 35, 4; 579-594
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noise exposure and hearing status among employees using communication headsets
Autorzy:
Pawlaczyk-Łuszczyńska, Małgorzata
Dudarewicz, Adam
Zaborowski, Kamil
Zamojska-Daniszewska, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2153012.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
noise-induced hearing loss
pure-tone audiometry
otoacoustic emissions
communication headsets
occupational exposure to noise
extended high-frequency audiometry
Opis:
Objectives The objective of this study was to assess the hearing of employees using communication headsets with regard to their exposure to noise. Material and Methods The study group comprised 213 employees, including 21 workers of the furniture industry, 15 court transcribers and 177 call center operators, aged 19–55 years, working with headsets for a period of up to 25 years. All the participants underwent a standard puretone audiometry, extended high-frequency audiometry (EHFA) as well as transient-evoked otoacoustic emissions (TEOAEs) and distortion-product otoacoustic emissions (DPOAEs). Noise exposure from headsets was evaluated using the microphone in a real ear technique according to PN-EN ISO 11904-1:2008. Results Personal daily noise exposure levels ranged 57–96 dB and exceeded 85 dB only in 1.4% of the call center operators. Forty-two percent of the participants had bilateral normal hearing in the standard frequency range of 250–8000 Hz, and 33% in the extended highfrequency range of 9–16 kHz. It was found that DPOAEs were present bilaterally in 59% of the participants. Reproducibility of TEOAE at >70% and signal-to-noise ratio at >6 was exhibited by 42% and 17% of them, respectively. The 3 subgroups of workers differed in age, gender, noise exposure and type of headsets in use. However, after adjusting for age and gender, significant differences between these subgroups in terms of hearing were mostly visible in EHFA. A significant impact of age, gender, daily noise exposure level and current job tenure on hearing tests results was also noted among the call center operators and the transcribers. The most pronounced were the effects of age and gender, whereas the impact of the daily noise exposure level was less evident. Conclusions It seems that EHFA is useful for recognizing early signs of noise-induced hearing loss among communication headset users. However, further studies are needed before any firm conclusions concerning the risk of hearing impairment due to the use of such devices can be drawn.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 5; 585-614
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tinnitus as the sole symptom of vestibular schwannoma – case report.
Autorzy:
Ochal-Choińska, Aleksandra
Lachowska, Magdalena
Zarębska- Karpieszuk, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1400524.pdf
Data publikacji:
2016
Wydawca:
Index Copernicus International
Tematy:
acoustic neuroma
tinnitus
hearing loss
pure tone audiometry
auditory evoked brainstem potentials
vestibular evoked myogenic potentials
Opis:
In this paper, we present a case report of a 26-year-old patient who had been experiencing isolated unilateral tinni-tus for 2 months. Audiologic examinations, such as pure tone, speech and impedance audiometry, ABR and vestibular evoked myogenic potential (VEMP) showed no abnormalities. The videonystagmography (VNG) and computerized dynamic posturography (CDP) also showed no pathology. Magnetic Resonance Imaging (MRI) was the only test that confirmed the presence of the vestibular schwannoma in this patient. Conclusions: MRI should be considered in pa-tients suspected of having a vestibular schwannoma with unilateral tinnitus as the only symptom, despite normal au-diological test results (with no retrocochlear findings).
Źródło:
Polski Przegląd Otorynolaryngologiczny; 2016, 5, 2; 46-50
2084-5308
2300-7338
Pojawia się w:
Polski Przegląd Otorynolaryngologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exposure to excessive sounds and hearing status in academic classical music students
Autorzy:
Pawlaczyk-Łuszczyńska, Małgorzata
Zamojska-Daniszewska, Małgorzata
Dudarewicz, Adam
Zaborowski, Kamil
Powiązania:
https://bibliotekanauki.pl/articles/2161930.pdf
Data publikacji:
2017-02-21
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
noise-induced hearing loss
music students
exposure to excessive sounds
pure-tone audiometry
hearing threshold levels
high-frequency notches
Opis:
Objectives The aim of this study was to assess hearing of music students in relation to their exposure to excessive sounds. Material and Methods Standard pure-tone audiometry (PTA) was performed in 168 music students, aged 22.5±2.5 years. The control group included 67 subjects, non-music students and non-musicians, aged 22.8±3.3 years. Data on the study subjects’ musical experience, instruments in use, time of weekly practice and additional risk factors for noise-induced hearing loss (NIHL) were identified by means of a questionnaire survey. Sound pressure levels produced by various groups of instruments during solo and group playing were also measured and analyzed. The music students’ audiometric hearing threshold levels (HTLs) were compared with the theoretical predictions calculated according to the International Organization for Standardization standard ISO 1999:2013. Results It was estimated that the music students were exposed for 27.1±14.3 h/week to sounds at the A-weighted equivalent-continuous sound pressure level of 89.9±6.0 dB. There were no significant differences in HTLs between the music students and the control group in the frequency range of 4000–8000 Hz. Furthermore, in each group HTLs in the frequency range 1000–8000 Hz did not exceed 20 dB HL in 83% of the examined ears. Nevertheless, high frequency notched audiograms typical of the noise-induced hearing loss were found in 13.4% and 9% of the musicians and non-musicians, respectively. The odds ratio (OR) of notching in the music students increased significantly along with higher sound pressure levels (OR = 1.07, 95% confidence interval (CI): 1.014–1.13, p < 0.05). The students’ HTLs were worse (higher) than those of a highly screened non-noise-exposed population. Moreover, their hearing loss was less severe than that expected from sound exposure for frequencies of 3000 Hz and 4000 Hz, and it was more severe in the case of frequency of 6000 Hz. Conclusions The results confirm the need for further studies and development of a hearing conservation program for music students. Int J Occup Med Environ Health 2017;30(1):55–75
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 1; 55-75
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing Status in Young People Using Portable Audio Players
Autorzy:
Pawlaczyk-Łuszczyńska, M.
Zaborowski, K.
Zamojska-Daniszewska, M.
Rutkowska-Kaczmarek, P.
Dudarewicz, A.
Śliwinska-Kowalska, M.
Powiązania:
https://bibliotekanauki.pl/articles/176501.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
portable audio players
PAPs
pure-tone audiometry
transient-evoked otoacoustic emissions
TEOAEs
hearing threshold levels
high-frequency notches
noise-induced hearing loss
Opis:
The aim of this study was to evaluate the hearing status in young adults using portable audio players (PAPs) in relation to their listening habits. The study included 58 subjects, aged 22.8±2.8 years, non-occupationally exposed to noise. Questionnaire inquiry aimed at collecting personal data, the information on PAPs usage habits, self-assessment of hearing status and identification of risk factors for noise-induced hearing loss (NIHL) were performed in study subjects. Hearing tests included pure-tone audiometry (PTA) and transient-evoked optoacoustic emission (TEOAE). All subjects were PAPs users. Depending on listening habits they were divided into the subgroups of “frequent” users (>1 h/day) and “non-frequent” users (≤1 h/day). There were no significant differences between subgroups in prevalence of NIHL risk factors and self-assessment of hearing status. However, frequent users more often complained of tinnitus and hyperacusis. Majority (81.9 %) of participants had normal hearing. Nevertheless, 6.9 % of audiograms showed high-frequency notches typical for NIHL. Both, the PTA and TEOAE indicated worse hearing in non-frequent users compared to frequent users. No significant differences in prevalence of high-frequency notches between subgroups were noted. The outcomes do not support some previous studies results that the excessive exposure to music listened through PAPs might result in accelerating of development of NIHL loss in young adults.
Źródło:
Archives of Acoustics; 2017, 42, 1; 113-120
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of jet engine noise on hearing of technical staff
Wpływ hałasu silników odrzutowych na słuch personelu technicznego
Autorzy:
Konopka, Wiesław
Pawlaczyk-Łuszczyńska, Małgorzata
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2166206.pdf
Data publikacji:
2014-12-19
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
hałas silników odrzutowych
uszkodzenie słuchu
audiometria tonalna
emisja otoakustyczna produktów zniekształceń nieliniowych
DPOAE
jet engine noise
hearing impairment
pure tone audiometry
distortion product otoacoustic emission
Opis:
Background: Due to high sound pressure levels (SPLs), noise produced by jet planes may be harmful to hearing of people working in their proximity. The aim of this study was to assess the effects of exposure to jet engine noise on technical staff hearing. Material and Methods: The study comprised 60 men, aged 24–50 years, employed in army as technical staff and exposed to jet engine noise for 6–20 years. The control group were 50 non-noise exposed males, aged 25–51 years. Exposure to noise emitted by jet engines was evaluated. Pure-tone audiometry (PTA) and distortion product otoacoustic emissions (DPOAE) were recorded in both groups. Results: Jet engines emitted broadband noise with spectrum dominated by components in the frequency range 315–6300 Hz (1/3-octave bands). Maximum A-weighted SPL during tests reached values of approx. 120–130 dB. Consequently, engine-servicing personnel (even in the case of a single engine test) was exposed to noise (at A-weighted daily noise exposure level above 95 dB) exceeding permissible levels. Averaged audiometric hearing threshold levels of technical staff were higher (≤ 17 dB HL, p < 0.001) than in the control group. Similarly, the DPOAE amplitude was lower (≤ 17 dB SPL, p < 0.01) in the noise-exposed subjects compared to the non-exposed ones. Significant reduction of DPOAE levels was mainly noted for high frequencies (3–6 kHz). Conclusions: Despite the usage of hearing protection devices, both PTA and DPOAE consistently showed poorer hearing in engine-servicing personnel vs. control group. Med Pr 2014;65(5):583–592
Wstęp: Hałas emitowany przez silniki odrzutowe ze względu na wysoki poziom dźwięku może być szkodliwy dla słuchu osób pracujących w ich sąsiedztwie. Celem pracy była ocena wpływu ekspozycji na hałas na stan słuchu techników obsługujących silniki odrzutowe. Materiał i metody: Badaniami objęto 60 mężczyzn w wieku 24–50 lat, zatrudnionych w wojsku i narażonych na hałas silników odrzutowych przez okres 6–20 lat. Grupę porównawczą stanowiło 50 mężczyzn w wieku 25–51 lat nienarażonych zawodowo na hałas. Oceniono ekspozycję na hałas emitowany przez silniki odrzutowe. Diagnostykę słuchu oparto na badaniu audiometrią tonalną i rejestracji emisji otoakustycznych produktów zniekształceń nieliniowych (distortion product otoacoustic emissions – DPOAE). Wyniki: Silniki odrzutowe emitowały hałas szerokopasmowy, w którym dominowały składowe z przedziału częstotliwości 315–6300 Hz (pasma 1/3-oktawowe). Maksymalny poziom dźwięku A w czasie testów osiągał 120–130 dB. W konsekwencji, nawet w przypadku pojedynczego testu, personel obsługujący silniki był narażony na hałas (dzienny poziom ekspozycji (L EX, 8h) > 95 dB) przekraczający wartości najwyższych dopuszczalnych natężeń hałasu w środowisku pracy. Progi słuchu w grupie techników obsługujących silniki odrzutowe były wyższe (≤ 17 dB HL, p < 0.001) niż w grupie porównawczej. Amplituda emisji otoakustycznych DPOAE była również niższa (≤ 17 dB SPL, p < 0,01) u osób narażonych na hałas w porównaniu z nienarażonymi. Jej istotne statystycznie obniżenie stwierdzono głównie dla wysokich częstotliwości (3–6 kHz). Wnioski: Mimo stosowania ochronników słuchu zarówno wyniki audiometrii tonalnej, jak i DPOAE wskazywały na gorszy słuch u techników obsługujących silniki odrzutowe niż u osób z grupy porównawczej. Med. Pr. 2014;65(5):583–592
Źródło:
Medycyna Pracy; 2014, 65, 5; 583-592
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena narażenia na hałas i czasowych zmian słuchu związanych z pracą na stanowisku instruktora fitness
An assessment of exposure to noise and temporary changes in hearing related to working as a fitness instructor
Autorzy:
Wolniakowska, Anna
Dudarewicz, Adam
Zaborowski, Kamil
Pawlaczyk-Łuszczyńska, Małgorzata
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2081843.pdf
Data publikacji:
2021-08-31
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ekspozycja zawodowa
hałas
czasowe zmiany słyszenia
audiometria tonalna
klub fitness
uszkodzenia słuchu spowodowane hałasem
occupational exposure
noise
temporary changes in hearing
pure tone audiometry
fitness club
noise-induced hearing impairment
Opis:
Muzyka jest dla wielu osób nieodłącznym elementem życia. W ostatnich latach głośna muzyka, zarówno grana na żywo, jak i odtwarzana, stanowi istotne źródło hałasu. Celem niniejszej pracy była ocena związku między ekspozycją na wysokie poziomy dźwięku a czasowym przesunięciem progu słuchu (temporary threshold shift – TTS) u osób pracujących na stanowisku instruktora fitness. Materiał i metody Badaniem objęto 29 osób (26 kobiet i 3 mężczyzn, średnia wieku: 33±6 lat) zatrudnionych w 8 klubach fitness. Poziomy dźwięków i charakterystykę częstotliwościową hałasu zmierzono z zastosowaniem dozymetrii indywidualnej. Progi słuchu oceniano za pomocą audiometrii tonalnej przeprowadzanej przed rozpoczęciem zajęć fitness oraz bezpośrednio po ich zakończeniu, otrzymując łącznie 116 audiogramów przed- i poekspozycyjnych.WynikiZawodowe narażenie instruktorów fitness na hałas trwało 60–120 min, a równoważny poziom ciśnienia akustycznego A (LAeq,T) w miejscu ich pracy wynosił 76,3–96,0 dB (M = 87,1 dB). W 12% indywidualnych pomiarów odnotowano przekroczenie najwyższego dopuszczalnego natężenia (NDN) hałasu na stanowisku pracy (NDN = 85 dB). U 41% badanych instruktorów zaobserwowano TTS o wielkości ≥6 dB dla częstotliwości 4 kHz.WnioskiPraca instruktorów w klubach fitness może stwarzać ryzyko uszkodzenia słuchu związanego z pracą zawodową. Med. Pr. 2021;72(4):391–397
Music is for many people an integral part of their lives. In recent years, loud music, whether recorded or played live, has been a significant source of noise. The aim of the study was to assess the relationship between exposure to high sound levels and temporary threshold shift (TTS) in people working as fitness instructors.Material and MethodsThe study included a total of 29 people (26 women and 3 men, age: 33±6 years) employed in 8 fitness clubs. The sound levels and the frequency characteristics of noise were assessed using individual dosimetry. Hearing threshold was evaluated by pre- and post-exposure pure tone audiometry (PTA), yielding a total of 116 audiograms.ResultsOccupational exposure of fitness instructors to noise lasted 60–120 min and the A-weighted sound pressure level (LAeq,T) in their workplace ranged 76.3–96.0 dBA (M = 87.1 dB). In 12% of individual measurements, the maximum admissible intensity (MAI) value for noise at the workplace was exceeded (MAI = 85 dB). In 41% of the surveyed instructors, a TTS of ≥6 dB at 4 kHz was observed.ConclusionsFitness instructors may be a risk of hearing impairment related to their work. Med Pr. 2021;72(4):391–7
Źródło:
Medycyna Pracy; 2021, 72, 4; 391-397
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy progi słuchu u pracowników przemysłu meblarskiego wynikają z ich narażenia na hałas?
Do hearing threshold levels in workers of the furniture industry reflect their exposure to noise?
Autorzy:
Pawlaczyk-Łuszczyńska, Małgorzata
Dudarewicz, Adam
Czaja, Norman
Bortkiewicz, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/2164306.pdf
Data publikacji:
2016-06-29
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ekspozycja zawodowa
hałas
audiometria tonalna
uszkodzenie słuchu spowodowane hałasem
czynniki ryzyka uszkodzenia słuchu
progi słuchu
occupational exposure
noise
pure-tone audiometry
noise-induced hearing loss (NIHL)
risk factors of NIHL
hearing threshold levels
Opis:
Wstęp Celem pracy była analiza stanu słuchu pracowników zakładu meblarskiego z uwzględnieniem ich narażenia zawodowego na hałas i występowania dodatkowych czynników ryzyka uszkodzenia słuchu spowodowanego hałasem. Materiał i metody W grupie 50 mężczyzn w wieku 20–57 lat, zatrudnionych bezpośrednio przy produkcji mebli, przeprowadzono pomiary hałasu, badania kwestionariuszowe i ocenę stanu słuchu z zastosowaniem audiometrii tonalnej. Rzeczywiste progi słuchu pracowników porównano z progami przewidywanymi, wyznaczonymi według normy PN-ISO 1999:2000 na podstawie ich wieku, płci i narażenia na hałas. Wyniki Badane osoby pracowały przez 3–14 lat w warunkach narażenia na hałas o jego dziennym poziomie ekspozycji 82,7–94,8 dB (średnia: 90,9 dB). U wszystkich osób średni próg słuchu dla częstotliwości 500 Hz, 1000 Hz, 2000 Hz i 4000 Hz nie przekraczał 25 dB, ale w przypadku 11% audiogramów zaobserwowano załamki wysokoczęstotliwościowe, typowe dla działania hałasu. Rzeczywiste progi słuchu pracowników w zakresie częstotliwości 3000–6000 Hz były zbliżone do przewidywanych według PN-ISO 1999:2000. Stwierdzono istotnie statystyczne różnice między progami słuchu w podgrupach osób z wyższym (> 78 mm Hg) i niższym (≤ 78 mm Hg) ciśnieniem rozkurczowym krwi, palących papierosy i niepalących oraz pracujących bez kontaktu lub w kontakcie z rozpuszczalnikami organicznymi. U osób z ww. dodatkowymi czynnikami ryzyka obserwowano większe ubytki słuchu. Wnioski Wyniki badań potwierdzają, że podczas szacowania ryzyka uszkodzenia słuchu spowodowanego hałasem i opracowywania programów ochrony słuchu pracowników konieczne jest uwzględnianie dodatkowych (poza hałasem) czynników ryzyka, w tym palenia papierosów, podwyższonego ciśnienia tętniczego krwi i równoczesnej ekspozycji na rozpuszczalniki organiczne. Med. Pr. 2016;67(3):337–351
Background The aim of the study was to analyze the hearing status of employees of a furniture factory with respect to their exposure to noise and the presence of additional risk factors of noise-induced hearing loss (NIHL). Material and Methods Noise measurements, questionnaire survey and assessment of hearing, using pure tone audiometry, were carried out in 50 male workers, aged 20–57 years, directly employed in the manufacture of furniture. The actual workers’ hearing threshold levels (HTLs) were compared with the predictions calculated according to PN-ISO 1999:2000 based on age, gender and noise exposure. Results Workers under study were exposed to noise at daily noise exposure levels of 82.7–94.8 dB (mean: 90.9 dB) for a period of 3–14 years. In all subjects, mean HTL at 500 Hz, 1000 Hz, 2000 Hz and 4000 Hz did not exceed 25 dB. Nevertheless, high frequency notches were found in 11% of audiograms. The actual workers’ HTLs at 3000–6000 Hz were similar to those predicted using PN-ISO 1999:2000. There were statistical significant differences between HTLs in subgroups of people with higher (> 78 mm Hg) and lower (≤ 78 mm Hg) diastolic blood pressure, smokers and non-smokers, and those working with organic solvents. Hearing loss was more evident in subjects affected by the additional risk factors specified above. Conclusions The results confirm the need to consider, in addition to noise, also some other NIHL risk factors, such as tobacco smoking, elevated blood pressure, and co-exposure to organic solvents when estimating the risk of NIHL and developing the hearing conservation programs for workers. Med Pr 2016;67(3):337–351
Źródło:
Medycyna Pracy; 2016, 67, 3; 337-351
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena czasowych zmian słuchu związanych z pracą na stanowisku barmana
Assessment of temporary hearing changes related to work as a bartender
Autorzy:
Wolniakowska, Anna
Zaborowski, Kamil
Dudarewicz, Adam
Pawlaczyk-Łuszczyńska, Małgorzata
Śliwińska-Kowalska, Mariola
Powiązania:
https://bibliotekanauki.pl/articles/2162600.pdf
Data publikacji:
2019-02-28
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
ekspozycja zawodowa
uszkodzenie słuchu spowodowane hałasem
hałas
czynniki ryzyka uszkodzenia słuchu spowodowanego hałasem
czasowe zmiany słyszenia
audiometria tonalna
occupational exposure
noise-induced hearing loss
noise
risk factors of NIHL
temporary changes in hearing
pure-tone audiometry
Opis:
Wstęp W przemyśle rozrywkowym hałas często osiąga wysokie poziomy ciśnienia akustycznego, jednak ryzyko uszkodzenia słuchu w tym sektorze nie zostało jeszcze dokładnie ocenione. Celem pracy była ocena związku między ekspozycją na wysoki poziom dźwięku a czasowym przesunięciem progu słuchu u osób pracujących na stanowisku barmana w lokalach rozrywkowych. Materiał i metody Badaniem objęto 18 barmanów (średni wiek: 25±7 lat) zatrudnionych w klubie muzycznym (N = 8), pubie (N = 5) i dyskotece (N = 5). Poziomy dźwięków oraz charakterystyka częstotliwościowa hałasu były określane za pomocą dozymetrii indywidualnej. Progi słuchu oceniano za pomocą audiometrii tonalnej przeprowadzanej przed rozpoczęciem dnia pracy oraz bezpośrednio (do 15 min) po jego zakończeniu. Badania słuchu przeprowadzono u barmanów w czasie 2 lub 3 sesji badawczych podczas pracy w weekendy. Uzyskano 92 audiogramy przed- i poekspozycyjne. Wyniki Uśrednione równoważne poziomy dźwięku odniesione do 8-godzinnego dnia pracy w ocenianych 3 lokalach muzycznych wynosiły 95 dBA, przekraczając ponad czterokrotnie dopuszczalne prawnie normy. U 77% badanych osób wykazano przynajmniej w 1 sesji pomiarowej czasowe przesunięcia progów słuchu ≥ 10 dB HL dla częstotliwości 4 kHz. Wnioski Osoby pracujące na stanowisku barmana stanowią grupę zawodową o podwyższonym ryzyku utraty słuchu. Niezbędne jest zwiększanie świadomości tego faktu oraz wdrażanie u tych pracowników programów ochrony słuchu, zgodnie z dyrektywą Komisji Europejskiej (EU 2003/10/WE). Med. Pr. 2019;70(1):17–25
Background Noise in entertainment industry often reaches high sound pressure levels. Nevertheless, the risk of hearing loss in this sector is insufficiently recognized. The aim of this study was the assessment of the relationship between noise exposure and temporary threshold shifts (TTS) for people working as bartenders at a variety of entertainment venues. Material and Methods The study comprised a total of 18 bartenders (mean age was 25±7 years old) employed at a music club (N = 8), pub (N = 5) and discotheque (N = 5). Personal dosimeters were used for determining noise levels and frequency characteristics. Hearing was evaluated by pre- (before work) and post-exposure (up to 15 min after the end of work) pure tone audiometry. Hearing tests were carried out for bartenders during 2 or 3 sessions while working on weekends. Results The mean personal noise exposure level normalized to a nominal 8-hour working day was 95 dBA, above 4 times higher than the accepted legal limit. The TTS values (10 dB HL or more) were significant at 4 kHz for both ears for 77% of bartenders. Conclusions People working as bartenders represent a professional group with an increased risk of hearing loss. Raising awareness of this fact and implementing hearing protection programs in this group of workers is urgently needed, in line with the European Commission Directive (EU Directive 2003/10/EC). Med Pr. 2019;70(1):17–25
Źródło:
Medycyna Pracy; 2019, 70, 1; 17-25
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies