Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal losses" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
An extended dynamic thermal model of a permanent magnet excited synchronous motor
Autorzy:
Mbo'o, Ch. P.
Hameyer, K.
Powiązania:
https://bibliotekanauki.pl/articles/140883.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal modeling
thermal network
finite element method
iron losses
permanent magnet excited synchronous machine (PMSM)
Opis:
The purpose of this paper is to develop a dynamic thermal model of a permanent magnet excited synchronous motor (PMSM). The model estimates the temperature at specific points of the machine during operation. The model is implemented using thermal network theory, whose parameters are determined by means of analytical approaches. Usually thermal models are initialized and referenced to room temperature. However, this can lead to incorrect results, if the simulations are performed when the electrical machine operates under “warm” conditions. An approach is developed and discussed in this paper, which captures the model in critical states of the machine. The model gives feedback by online measured quantities to estimate the initial temperature. The paper provides an extended dynamic thermal model, which leads to a more accurate and more efficient thermal estimation.
Źródło:
Archives of Electrical Engineering; 2013, 62, 3; 375-386
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of loss distribution of conventional boost, Z-source and Y-source converters for wide power and voltage range
Autorzy:
Gadalla, B. S.
Schaltz, E.
Siwakoti, Y.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/136154.pdf
Data publikacji:
2017
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
boost converter
Z-source converter
Y-source converter
winding losses
core losses
gain
thermal design
reliability
Opis:
Boost converters are needed in many applications which require the output voltage to be higher than the input voltage. Recently, boost type converters have been applied for industrial applications, and hence it has become an interesting topic of research. Many researchers proposed different impedance source converters with their unique advantages as having a high voltage gain in a small range of duty cycle ratio. However, the thermal behaviour of the semiconductor devices and passive elements in the impedance source converter is an important issue from a reliability point of view and it has not been investigated yet. Therefore, this paper presents a comparison between the conventional boost, the Z-source, and the Y-source converters based on a thermal evaluation of the semiconductors. In addition, the three topologies are also compared with respect to their efficiency. In this study the results show that the boost converter has higher efficiency than the Z-source and Y-source converter for these specific voltage gain of 2 and 4. The operational principle, mathematical derivations, simulation results and final comparisons are presented in this paper.
Źródło:
Transactions on Environment and Electrical Engineering; 2017, 2, 1; 1-9
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison between thermal simulation results generated by PLECS software and laboratory measurements
Autorzy:
Mysiński, Wojciech
Sysło, Bartłomiej
Powiązania:
https://bibliotekanauki.pl/articles/377458.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
thermal simulation
PLECS
buck converter
thermal time constant
IGBT
diode
power losses
Opis:
This article deals with the subject of simulation of power losses and thermal processes occurring in semiconductors, as illustrated by an example of a DC/DC buck converter. The simulations were performed in PLECS software. The results obtained from the program were compared with measurement results of a laboratory converter model. The physical model is based on the same components as assumed in the simulation. Similarly, the parameters of the transistor control signal were the same. During operation of the converter, the temperature changes were analyzed using a K-type thermocouple. Based on the obtained results of the temperature measurement in the steady state of the converter operation, the correctness of the simulation carried out in the PLECS program was verified and confirmed.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2019, 99; 29-40
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromagnetic analysis, efficiency map and thermal analysis of an 80-kW IPM motor with distributed and concentrated winding for electric vehicle applications
Autorzy:
Młot, Adrian
Korkosz, Mariusz
Lechowicz, Andrzej
Podhajecki, Jerzy
Rawicki, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/2172808.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC losses
concentrated winding
distributed winding
motor performance
radial flux permanent magnet motor
slot fill factor
thermal analysis
Opis:
This paper presents a comparison of an AC radial flux interior permanent magnet (IPM) motor with the distributed winding (DW) and concentrated winding (CW). From time to time, manufacturers of electric vehicles change the design of electric motors, such changes may include changing the DW into CW and vice versa. A change to the winding in a radial permanent magnet synchronous motor may lead to a change in motor parameters during motor operation and /or change in the distribution of the magnetic field and thermal circuit of the electrical machine. The electromagnetic analysis, efficiency map, mechanical stress, and thermal analysis of the machine with the DW and CW are presented in this paper. This article describes the advantages and disadvantages of selected stator winding designs and helps understand manufacturers’ designers how the DW and CW play a key role in achieving the designed motor’s operational parameters such as continuous performance. Analyzing the performance of both machines will help identify their advantages and disadvantages with regard to thermal phenomena, magnetic field and operational parameters of the presented IPM prototypes. Both prototypes are based on commonly used topologies such as 12/8 (slot/pole) and 30/8 (slot/pole) IPM motors consisting of magnets arranged in a V-shape. The AC IPM motor was designed for an 80 kW propulsion system to achieve 170 N·m at a base speed of 4 500 rpm. Modern CAD tools are utilized throughout the numerical computations based on 2-D finite element methods. Selected test data are used to verify and validate the accuracy of finite element models.
Źródło:
Archives of Electrical Engineering; 2022, 71, 4; 981--1002
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetic & exergetic analysis of a parabolic trough: concentrated solar power plant
Autorzy:
Nagpal, Mohit
Maithani, Rajesh
Kumar, Suresh
Powiązania:
https://bibliotekanauki.pl/articles/2142893.pdf
Data publikacji:
2021
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
solar energy
exergy
thermal efficiency
heat gain
heat losses
parabolic trough
collectors
energia słoneczna
egzergia
wydajność termiczna
zyski ciepła
straty ciepła
kolektory
Opis:
Solar energy is the most affordable source of energy. Parabolic trough systems are used to concentrate and extract heat, therefore it’s very significant to analyse its performance in terms of energy and exergy. Exergy based analysis of the system ensures the eradication of losses, resulting in the yield of energy of the highest quality. In this paper, an investigation has been carried out using numerical simulation with an objective of analysis of Parabolic Trough Collectors on the basis of energy and exergy. Detailed second law analysis has been performed by varying the system and operating parameters through computer simulation. Exergy output has been determined by analysing the effect of major system parameters, namely, mirror reflectivity, glass transmissivity, absorptivity, the diameter of glass envelop, and the receiver. The operating parameters considered in the investigation are insolation and temperature rise parameters. The extensive investigation of the parabolic trough of a concentrated solar power plant for various design parameters in the range of operating parameters reveals that it is beneficial to operate the system at higher temperature as opposed to the preference of the operating system at lower temperature from purely thermal considerations.
Źródło:
Acta Innovations; 2021, 40; 19-30
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of power losses in a high-frequency planar transformer using a thermal camera
Autorzy:
Barlik, R.
Nowak, M.
Grzejszczak, P.
Zdanowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/140759.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power losses estimation
thermal camera
thermal calibration
planar transformer
Dowell’s and Steinmetz’s equations
Opis:
This paper presents the implementation of a thermal camera for the quantitative estimation of power losses in a high frequency planar transformer (100 kHz/ 5600 VA). The methodology is based on the observation of the transient temperature rise and determination of the power losses by means of curves representing the derivative of temperature as a function of power losses dissipated in the transformer. First, the thermal calibration characteristics had to be obtained from a simple experiment, where power losses are generated by DC current in the ferrite core and windings. Next, experimental investigations focused on the determination of the transformer power losses for a short circuit and no load, with a resistive load and with the rectifier as a load were carried out. Finally, to verify the obtained results, analytical calculations based on Dowell’s and modified Steinmetz’s equations were additionally made, which showed a good convergence. The proposed method is easy to implement and can be used as an alternative to the calorimetric method which is time-consuming and requires a complicated measurement setup.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 613-627
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Infrared building inspection with unmanned aerial vehicles
Badania termowizyjne budynków z wykorzystaniem bezzałogowych statków lotniczych
Autorzy:
Krawczyk, J. M.
Mazur, A. M.
Sasin, T.
Stokłosa, A. W.
Powiązania:
https://bibliotekanauki.pl/articles/213328.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
energy efficiency
unmanned aerial vehicles
energy modeling
heat losses
thermal imaging
sustainable energy development
final energy consumption
building sector
efektywność energetyczna
bezzałogowe systemy latające (BSL)
modelowanie w energetyce
straty ciepła
badania termowizyjne
zrównoważony rozwój energetyczny
finalne zużycie energii
sektor budowlany
Opis:
Article discusses the subject of energy efficiency in the construction and building sector and the use of unmanned aerial vehicles in order to study energy consumption in buildings. At the beginning, the concept of energy efficiency in buildings is presented, its importance and impact on the environment. Then, the article discusses the current situation, the trends in Europe and the potentials of this sector together with the most important legal issues related to the topic of energy efficiency. The next section explores the effects of buildings on the environment, in particular, through heat loss. The article also outlines the importance of research methods and thermal imaging. Specifically developed unmanned aircraft classification is adapted for the use in thermal studies. The topic is discussed in terms of both the characteristics and structure, as well as the advantages and disadvantages of the use of such solutions. Possible paths of development in this subject are presented, as well as problems and concerns. The last part focuses on the example of the use of unmanned platform to study thermal imaging of a residential building. This is a case study carried out in December 2014.
Artykuł omawia tematykę efektywności energetycznej w budownictwie oraz wykorzystanie bezzałogowych systemów latających do badania energochłonności budynków. Na początku przedstawione jest pojęcie efektywności energetycznej w budynkach, jej znaczenie oraz wpływ na środowisko. Następnie omówiona jest obecna sytuacja, trendy w Europie oraz potencjał jakim dysponuje ten sektor wraz z najistotniejszymi kwestiami prawnymi związanymi z tematyką efektywności energetycznej. Kolejny dział przybliża nam zagadnienia wpływu budynków na środowisko, w szczególności poprzez straty ciepła. Artykuł nakreśla również sposoby oraz znaczenie badań termowizyjnych. Szczegółowo opracowana jest klasyfikacja samolotów bezzałogowych przystosowanych do wykorzystania w badaniach termowizyjnych. Temat omówiony jest zarówno pod kątem charakterystyki i konstrukcji, jak również wad i zalet stosowania takich rozwiązań. Analizowane są również obecne ścieżki rozwoju w tej tematyce, problemy i wątpliwości. Ostatnia część skupia się na przykładzie wykorzystania platformy bezzałogowej do badania termowizyjnego budynku mieszkalnego. Jest to studium przypadku wykonane w Grudniu 2014 roku.
Źródło:
Prace Instytutu Lotnictwa; 2015, 3 (240); 32-48
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the Results of Combined Reclamation on the Particular Stages of Grain Matrix Recovery
Autorzy:
Łucarz, M.
Dańko, R.
Dereń, M.
Skrzyński, M.
Powiązania:
https://bibliotekanauki.pl/articles/354022.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
waste moulding (foundry) sand
mechanical reclamation
thermal reclamation
roasting losses
grain-size analysis
Opis:
In this article, there were presented the results of research on combined mechanical and thermal regeneration of waste moulding sand with furfuryl resin originated from one of national foundries manufacturing aluminium alloys castings. Attempts of mechanical reclamation were led on the REGMAS reclaimer enabling to realize preliminary and primary reclamation with use of two modes of mechanical interactions on waste moulding sand. In the first attempt the reclaimer worked without any additional regenerating elements, and as the second solution, the reclaimer operated with additional crushing and abrasive elements to increase the result of primary reclamation. Thermal reclamation was led in the prototypic thermal reclaimer, enabling to fully control the process of grain matrix recovery. As a result of completed investigations the small efficiency of mechanical reclamation was determined. However, use of combined regeneration allowed for obtaining grain matrix of high purity. Thermal regeneration was conducted in prototypic thermal reclaimer. Evaluation of reclaim (reclaimed material) quality was carried out in the way of iginition losses and grain-size analysis, surface morphology and also by executing of strength testing of moulding sand prepared on obtained grain matrix for the particular reclamation operations.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 4; 2151-2158
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie jakości mięsa wołowego pochodzącego z różnych rejonów geograficznych pod względem skurczu i ubytków masy podczas obróbki termicznej
Quality evaluation of beef from different geographic regions based on thermal losses and shrinkage
Autorzy:
Modzelewska-Kapituła, M.
Cierach, M.
Powiązania:
https://bibliotekanauki.pl/articles/2070374.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wołowina
skurcz termiczny
ubytek masy podczas smażenia
steki
beef
thermal shrinkage
thermal losses
steaks
Opis:
W pracy porównano ubytki masy oraz wielkość skurczu termiczneg steków z wołowiny polskiej, szkockiej, argentyńskiej, brazylijskiej i pochodzącej z USA. Najmniejszy ubytek masy i skurcz po 20 minutach chłodzenia odnotowano w stekach z wołowiny amerykańskiej, szkockiej i brazylijskiej. Steki te jednak nie różniły się od pozostałych pod względem soczystości.
Weight losses and thermal shrinkage of steaks prepared from Polish, Scottish, Argentinian, Brazilian and USA beef were investigated in this study. The least weight losses and shrinkage values after 20 minutes of chilling were noted in steaks originated from the USA, Scotland and Brazil. However there were no differences between them and the rest of steaks in terms of juiciness evaluated by sensory assessment.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 2; 104-105
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal analytical winding size optimization for different conductor shapes
Autorzy:
Wojda, R. P.
Powiązania:
https://bibliotekanauki.pl/articles/140709.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Dowell’s equation
Eddy currents
FEM
inductors
optimization
proximity effect
skin effect
thermal effects
winding losses
Opis:
The aim of this paper is to derive an analytical equations for the temperature dependent optimum winding size of inductors conducting high frequency ac sinusoidal currents. Derived analytical equations are useful designing tool for research and development engineers because windings made of foil, square-wire, and solid-round-wire windings are considered. Temperature dependent Dowell’s equation for the ac-to-dc winding resistance ratio is given and approximated. Thermally dependent analytical equations for the optimum foil thickness, as well as valley thickness and diameter of the square-wire and solid-round-wire windings are derived from approximated thermally dependent ac-to-dc winding resistance ratios. Minimum winding ac resistance of the foil winding and local minimum of the winding ac resistance of the solid-round-wire winding are verified with Maxwell 3D Finite Element Method simulations.
Źródło:
Archives of Electrical Engineering; 2015, 64, 2; 197-214
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Characterization of High-Frequency Flyback Power Transformer
Autorzy:
Kasikowski, R.
Gołaszewski, J.
Więcek, B.
Farrer, M.
Powiązania:
https://bibliotekanauki.pl/articles/114581.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
IR thermography
power losses
H-F flyback transformer
thermal impedance
Opis:
This paper presents preliminary thermographic measurements and a simple thermal analysis of power losses in high-frequency (H-F) transformers used in AC-DC power converters. The analysis is based on complex thermal impedance and time constant distribution. The main aim of this research was to consider quantitatively the contribution of different power losses in the H-F transformer, including fringing flux effect.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 237-241
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of Infrared Imaging Techniques to Investigate Thermal Losses of Flat Plate Solar Collectors
Autorzy:
Znaczko, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/30145702.pdf
Data publikacji:
2023
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
infrared imaging
solar collector
thermal losses
radiation
environmental protection
Opis:
The paper presents ways to use advanced infrared imaging techniques to study and analyze the thermal losses of a flat plate solar collector. The techniques allowed us to precisely locate and measure areas where unwanted thermal losses occurred on the surface of the collectors studied. The study showed that these losses have a key impact on the energy efficiency of these devices. It was found that using the proposed methodology allows not only the detection of defects in existing structures but also the optimization of the design process of new technical solutions. The temperature of the working medium has a significant effect on heat losses on all analyzed surfaces. However, the influence of the medium flow varies depending on the specific surface. The conclusions of the research suggest that infrared imaging is a valuable tool in developing solar thermal systems, contributing to the reliability and efficiency of these systems. The technique is an important step toward sustainable and economical use of solar energy. Increasing the efficiency of the equipment used to carry out the photothermal conversion process will allow more efficient use of available renewable energy sources. It will have a positive impact on environmental protection.
Źródło:
Rocznik Ochrona Środowiska; 2023, 25; 342-356
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ współczynnika kształtu A/V na wielkość strat ciepła w budynku w świetle rosnących wymogów dotyczących izolacyjności termicznej przegród budowlanych
Influence of building’s shape factor on its heat losses with respect to increasing requirements for building’s thermal insulation
Autorzy:
Kaczmarzyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/104841.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
współczynnik kształtu A/V
izolacyjność termiczna
straty ciepła
obudowa termiczna budynku
A/V shape factor
thermal insulation
heat losses
building’s thermal envelope
Opis:
Celem niniejszego artykułu było określenie jaki faktyczny wpływ na wielkość sezonowych strat ciepła przez obudowę termiczną budynku miało kiedyś i może mieć obecnie zachowanie zwartej bryły budynku. W artykule przybliżono pojęcia izolacyjności termicznej i współczynnika przenikania ciepła przegród budowlanych. Przedstawiono tu także krajowe wymogi dotyczące izolacyjności termicznej przegród budowlanych, jakie obowiązywały w minionych dekadach, jakie obowiązują obecnie i te, które będą stawiane wobec przegród budowlanych w najbliższych latach. Wyjaśniono także, czym dla budynku jest współczynnik kształtu A/V i powód, dla którego kształt bryły budynku może wpływać na jego charakterystykę energetyczną. Zaprezentowano wnioski sformułowane przez innych autorów, których prace dotyczą optymalizacji kształtu bryły budynku pod względem cieplnym. Przytoczono również krytyczne opinie dotyczące wpływu takiej optymalizacji kształtu na atrakcyjność architektury obiektów budowlanych. Metodę badawczą oparto na obliczeniach sezonowych strat ciepła w budynkach o różnych stosunkach powierzchni przegród zewnętrznych do kubatury budynku A/V. Obliczenia przeprowadzono dla 27 modeli budynków o identycznej powierzchni wewnętrznej i kubaturze wewnętrznej, lecz różniących się proporcjami wymiarów i liczbą kondygnacji. W obliczeniach wzięto pod uwagę dziewięć zestawów wartości współczynników przenikania ciepła przegród zewnętrznych, odpowiadających dawnym, aktualnym i przyszłym wymogom krajowym. Różnice w wartościach sezonowych strat ciepła uzyskane dla każdego z zestawów zinterpretowano jako potencjalne oszczędności energetyczne, wynikające z zachowania zwartej bryły budynku i ograniczenia wartości współczynnika kształtu A/V. Wyniki zestawiono i na ich podstawie sformułowano stosowne wnioski.
The purpose of this paper was to determine former, current and future impact of building’s shape compactness on its heat losses. The article explains such terms as thermal insulation and heat transfer coefficient of building barrier’s, as well as the history of Polish national regulations concerning that subject. It was also explained, what building shape factor is, and what may be its potential impact on building’s efficient Energy use. The paper presented conclusions of numerous research on building shape optimization, including critical opinions about architectural effects of the process. The scientific method was based on calculations of seasonal heat losses in multiple buildings varying with their volume to Surface area ratio. Calculations were conducted for twenty seven buildings of the same floor Surface area and interior volume, but of different proportions and number of storeys. Calculations considered nine groups of heat transfer coefficient values for building barriers, that corresponded to former, current and future standards, established by polish regulations Differences in acquired values of seasonal heat loses were interpreted as potential energy savings to be obtained by applying thermal envelopes with low shape factors. Presented results have been compared and basing on them, final conclusions were formed.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 2/II; 45-54
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wprowadzenie do wykorzystania technologii lotniczych w badaniach termowizyjnych budynków
Introduction to the use of aerial technology in the thermal imaging of buildings
Autorzy:
Krawczyk, J. M.
Mazur, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/2065444.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska
Tematy:
efektywność energetyczna
bezzałogowe systemy latające (BSL)
modelowanie w energetyce
straty ciepła
badania termowizyjne
energy efficiency
unmanned aerial vehicles (UAVs)
energy modeling
heat losses
thermal imaging
Opis:
Artykuł omawia tematykę efektywności energetycznej w budownictwie oraz wykorzystanie bezzałogowych systemów latających do badania energochłonności budynków. Przedstawiono pojęcie efektywności energetycznej w budynkach, jej znaczenie oraz wpływ na środowisko. Przybliżono zagadnienia wpływu budynków na środowisko w szczególności poprzez straty ciepła. Omówiono również sposoby oraz znaczenie badań termowizyjnych. Zaprezentowano klasyfikację samolotów bezzałogowych przystosowanych do wykorzystania w badaniach termowizyjnych. Temat został omówiony zarówno pod kątem charakterystyki energetycznej, konstrukcji, jak i wad oraz zalet stosowania takich rozwiązań. Dokonano również analizy obecnych ścieżek rozwoju w tej dziedzinie, wskazano także pewne problemy i wątpliwości.
Article discusses the subject of energy efficiency in the construction and building sector and the use of unmanned aerial vehicles in order to study energy consumption in buildings. At the beginning, the concept of energy efficiency in buildings is presented, its importance and impact on the environment. The next section explores the effects of buildings on the environment, in particular, through heat loss. The article also outlines the importance of research methods and thermal imaging. Specifically developed unmanned aircraft classification is adapted for the use in thermal studies. The topic is discussed in terms of both the characteristics and structure, as well as the advantages and disadvantages of the use of such solutions.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2016, 1 (17); 33--40
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies