Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "temperature coefficient" wg kryterium: Temat


Tytuł:
Offset Drift Dependence of Hall Cells with their Designed Geometry
Autorzy:
Paun, M. A.
Sallese, J. M.
Kayal, M.
Powiązania:
https://bibliotekanauki.pl/articles/226531.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
hall effect sensor
individual and residual offset drift
temperature coefficient
Opis:
In this paper, the performance of CMOS Hall Effect Sensors with four different geometries has been experimentally studied. Using a characteristic measurement system, the cells residual offset and its temperature behavior were determined. The offset, offset drift and sensitivity are quantities that were computed to determine the sensors performance. The temperature coefficient of specific parameters such as individual, residua offset and resistance has been also investigated. Therefore the optimum cell to fit the best in the performance specifications was identified. The variety of tested shapes ensures a good analysis on how the sensors performance changes with geometry.
Źródło:
International Journal of Electronics and Telecommunications; 2013, 59, 2; 169-175
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Sensitivity of Propellant Combustion and Temperature Coefficients of Gun Performance
Autorzy:
Boulkadid, M. K.
Lefebvre, M. H.
Jeunieau, L.
Dejeaifve, A.
Powiązania:
https://bibliotekanauki.pl/articles/358071.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
firing temperature
temperature sensitivity
temperature coefficient
ball propellant
ageing
ballistic firing
closed vessel tests
Opis:
One of the objectives of gun propellant research is to develop green formulations of gunpowder that should be less temperature sensitive than the current gun propellant. The temperature sensitivity of these new green formulations of the propellant should be measured to identify the less temperature sensitive green formulations. However, there are deficiencies in the methodologies for the measurement of the temperature sensitivity of gun propellants. Therefore, the aim of this investigation was to fill the gap by establishing a method for the measurement of the temperature sensitivity of deterred gun propellants by closed vessel tests. The temperature sensitivity of the burning rate of ball propellants and the temperature coefficients of gun performance were determined using closed vessel tests and ballistic firing, respectively. Specific definitions of temperature sensitivity and temperature coefficients were evaluated. The relation between these parameters has never been explicitly investigated previously. Assessing the temperature sensitivity of propellants by closed vessel tests is of added value to the range of ballistic tests if the results of these tests can be well correlated to the results of ballistic firings. Therefore, a comparison between both parameters was made. A correspondence has been observed between the temperature sensitivity of the propellant burning rate, as obtained from closed vessel tests, and the temperature coefficients as obtained from ballistic firings.
Źródło:
Central European Journal of Energetic Materials; 2016, 13, 4; 1005-1022
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ryzyko wystąpienia kondensacji pary wodnej w zewnętrznych przegrodach poziomych
Risk of condensation in the horizontal external partitions
Autorzy:
Gawryś, D.
Powiązania:
https://bibliotekanauki.pl/articles/105039.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
współczynnik temperaturowy
dach zielony
skraplanie pary wodnej
temperature coefficient
green roof
condensation
Opis:
Celem pracy jest sprawdzenie wystąpienia kondensacji pary wodnej w stropodachu zielonym, będącym pokryciem budynku mieszkalnego wielorodzinnego, dla którego określono trzecią klasę obciążenia wilgocią - budynki o niskim stopniu zaludnienia. Stropodach cechuje się układem warstw, w których zmiennej grubości termoizolacja jest układana ze spadkiem w kierunku koryta odwadniającego. Minimalna grubość termoizolacji to 25 cm, a maksymalna będąca wynikiem obliczeń, to około 31,5 cm. Wyznaczając grubość termoizolacji w poszczególnych miejscach stropodachu posłużono się krokiem wynoszącym 50 cm tworząc siatkę punktów opisujących poszczególne przekroje stropu. Sprawdzenia dokonano w oparciu o definicję współczynnika temperaturowego. Średnie miesięczne wartości temperatury na zewnątrz budynku uzyskano w oparciu o bazę danych Instytutu Meteorologii i Gospodarki Wodnej za rok 2015. Na początku obliczono miesięczne zewnętrzne ciśnienie pary wodnej. Następnie wyznaczono zewnętrzne ciśnienie pary wodnej oraz nadwyżkę wewnętrznego ciśnienia pary wodnej w sposób odpowiedni dla trzeciej klasy obciążenia wilgocią. Kolejno obliczenie wewnętrznego ciśnienia pary wodnej i minimalnego dopuszczalnego ciśnienia pary nasyconej doprowadziło do obliczenia minimalnej dopuszczalnej temperatury na powierzchni przegrody. Dla założonego układu warstw dachowych nie występuje ryzyko wystąpienia kondensacji pary wodnej, a co za tym idzie uniknięto wystąpienia pleśni i grzybów wewnątrz budynku. Ma to bardzo duże znaczenie nie tylko estetyczne, ale szczególnie ważne wobec osób cierpiących na alergię. Uniknięcie wszelkiego rodzaju grzybów i pleśnie w pomieszczeniu pomaga stworzyć właściwy mikroklimat.
The aim is to check the occurrence of condensation on the flat roof of green, which is covering multifamily residential building, for which specified third class load damp - buildings with low population. Flat roof has a layer system in which the variable thickness of insulation is laid with a fall in the direction of the irrigation channel. The minimum thickness of insulation is 25 cm and the maximum result of the calculation, is about 31.5 cm. Determining the thickness of the insulation in the various places of the flat roof was used in increments of 50 cm to form a grid of points that describe the individual sections of the floor. Checks were made on the basis of the definition of the temperature coefficient. The average monthly temperature on the outside of the building was achieved based on the database of the Institute of Meteorology and Water Management for the year 2015. At the beginning of calculated monthly external pressure steam. Then they set the external pressure steam and excess internal pressure steam in a manner appropriate for the third class of moisture load. Successively calculating the internal vapor pressure and the minimum allowable vapor pressure led to calculate the minimum allowable surface temperature of the partition. For founded the layers of the roof there is a risk of condensation. This is very important not only aesthetic, but especially important for people with allergies. Avoiding all kinds of fungi and molds in the room helps to create the right microclimate.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 359-367
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania współczynników temperaturowych wzorców impedancji
Autorzy:
Musioł, K.
Powiązania:
https://bibliotekanauki.pl/articles/155735.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termostat powietrzny
współczynnik temperaturowy
wzorzec impedancji
air thermostat
temperature coefficient
impedance standards
Opis:
Investigations of the temperature coefficients of impedance standards
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 597-600
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Local Temperature Sensitivity Coefficients of a Deterred Spherical Single Base Gun Propellant
Autorzy:
Boulkadid, K.
Lefebvre, M. H.
Jeunieau, L.
Dejeaifve, A.
Powiązania:
https://bibliotekanauki.pl/articles/358203.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
initial temperature
temperature sensitivity coefficient
deterred propellant
closed vessel tests
infrared microscopy
Opis:
In our previous investigation, we measured the global temperature sensitivity coefficient of a deterred spherical single base gun propellant following an experimental procedure that did not allows us to determine the local temperature sensitivity coefficients of the deterred and undeterred parts of the investigated propellant. In this paper, we propose an experimental methodology to measure the local temperature sensitivity coefficients of both parts of the spherical deterred gun propellant. This methodology can be summarized as follows: Firstly, we separated the ranges of pressure where the combustion of the deterred and the undeterred parts of the spherical propellant occurs by means of infrared (IR) microscopy measurements. Then the burning rate of the propellant as a function of pressure was calculated according to STANAG 4115 at different initial temperatures. Finally, we determined the local temperature sensitivity coefficients of each part of the spherical propellant.
Źródło:
Central European Journal of Energetic Materials; 2017, 14, 4; 952-965
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of the efficiency of improved regenerative decentralised ventilators Vents Twin Fresh
Autorzy:
Mileikovskyi, Viktor
Vakulenko, Daria
Powiązania:
https://bibliotekanauki.pl/articles/2065593.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
heat regeneration
heat recovery
CFD
temperature coefficient of efficiency
regeneracja ciepła
odzysk ciepła
temperaturowy współczynnik sprawności
Opis:
The work is devoted to modelling Twin Fresh ventilator efficiency. The main aim is to simulate heat exchanged in a heat regenerator in variable conditions. The mathematical model is based on Navier-Stokes equations for laminar flow. The model is designed to achieve an adequate time for calculation and sufficient precision. The results show high efficiency of heat recovery in the order of 97.4%.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 1; 61--67
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on New Al-Ag-Mo Alloys Dedicated to Wire Applications in Overhead Power Lines
Autorzy:
Grzebinoga, Justyna
Mamala, Andrzej
Ściężor, Wojciech
Kowal, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/2201984.pdf
Data publikacji:
2023
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
aluminum
silver
molybdenum
continuous casting
drawing
wire
conductivity
thermal resistance
temperature coefficient of resistance
rheological properties
HTLS conductors
Opis:
The latest research work in the field of electric power systems focuses on the development of new wire materials which will allow the increase of the transmission capacity of power lines currently in use. The reason for this research was the often limited possibilities of continuous and failure-free transmission of electricity. In this paper, the authors present research on a new aluminium-based alloy dedicated for use as a conductive braid in the HTLS cable group. There are many technical solutions for this group of cables on the market, although they are solutions with a number of disadvantages, ranging from their high price, various operational shortcomings, complicated installation techniques, and ending with the risk of monopolistic practices, which is related to the inability to attract several competitive suppliers. The main aim of the research was to develop a new alloy based on aluminium with the addition of silver and molybdenum dedicated for use in special overhead power cables. Experimental research on new materials focused on obtaining the necessary knowledge to produce an overhead wire from these alloys with higher current carrying capacity in relation to the currently used conventional wire materials based on aluminium.
Źródło:
Journal of Casting & Materials Engineering; 2023, 7, 1; 9--14
2543-9901
Pojawia się w:
Journal of Casting & Materials Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage reference with programmable temperature coefficient and offset voltage compensation
Autorzy:
Gruber, D.
Hilber, G.
Ostermann, T.
Powiązania:
https://bibliotekanauki.pl/articles/398075.pdf
Data publikacji:
2011
Wydawca:
Politechnika Łódzka. Wydział Mikroelektroniki i Informatyki
Tematy:
napięcie odniesienia
energetyczne pasmo wzbronione
współczynnik temperaturowy
napięcie niezrównoważenia
kalibracja
voltage reference
band gap
temperature coefficient
offset voltage
trimmable
programmable
calibration
Opis:
This paper demonstrates an integrated circuit for compensation of errors in voltage references, that not only is able to compensate first order changes of the temperature coefficient, but can also correct for the offset error that is unavoidable in production due to variations in process conditions and mismatches. The temperature compensation circuit is programmable via three control bits, the remaining offset error is compensated by setting eight control bits and an external provided reference voltage. The compensation procedure can be controlled by an internal digital block or via external signals. The actual calibration data can then be saved in several possible ways (EPROM, laser fuses, external Memory, ...). Extensive simulations and measurements show that the described circuit reduces the average temperature error by more than 40% and the overall absolute error by more than 90% wth regards to the uncalibrated reference voltage.
Źródło:
International Journal of Microelectronics and Computer Science; 2011, 2, 2; 73-80
2080-8755
2353-9607
Pojawia się w:
International Journal of Microelectronics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oddziaływanie termiczne strugi wodno-lodowej podczas usuwania powłok lakierniczych
Thermal impact of the water-ice jet during the removal of varnish coats
Autorzy:
Chomka, G.
Powiązania:
https://bibliotekanauki.pl/articles/316837.pdf
Data publikacji:
2012
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
struga wodno-lodowa
powłoka lakiernicza
temperatura
współczynnik wyrównania temperatury
water-ice jet
varnish coat
temperature
temperature alignment coefficient
Opis:
W artykule omówiono oddziaływanie termiczne, jakie wywiera wysokociśnieniowa struga wodnolodowa na powłokę lakierniczą oraz materiał podłoża. Rozpatrzono kierunek rozchodzenia się ciepła zgodny z posuwem strugi oraz występujący w głąb materiału.
The article covers a thermal impact of a high-pressure water-ice jet on the varnish coat and the base material. The direction was considered of the propagation of heat that is compliant with the jet feed and the one that occurs inside the material.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2012, 13, 5; 94-101
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości termofizyczne zamrażanej żywności
Thermo-physical properties of frozen food
Autorzy:
Niesteruk, R.
Obidziński, S.
Powiązania:
https://bibliotekanauki.pl/articles/291135.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
ciepło właściwe
entalpia
współczynnik przewodzenia ciepła
współczynnik wyrównywania temperatury
gęstość
specific heat
enthalpy
conduction coefficient
temperature equalizing coefficient
density
Opis:
W pracy przedstawiono zmiany ciepła właściwego, entalpii, współczynnika przewodzenia ciepła, dyfuzyjności cieplnej oraz gęstości produktów spożywczych podczas zamrażania. Zmiany właściwości termofizycznych są wynikiem przemiany fazowej wody w lód.
The work presents changes observed in specific heat, enthalpy, conduction coefficient, thermal diffusivity, and density of foodstuff while freezing. Changes in thermo-physical properties result from phase transition of water into ice.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 9, 9; 225-232
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the influence of mechanical cooling on the increase in silicone photovoltaic cells efficiency
Ocena wpływu mechanicznego chłodzenia na wzrost wydajności krzemowych ogniw PV
Autorzy:
Klonowski, M.
Zbytek, Z.
Żurowski, K.
Nawrocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/335191.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
photovoltaics
efficiency
temperature power coefficient
silicone PV cells
fotowoltaika
sprawność
współczynnik temperaturowy mocy
krzemowe ogniwa PV
Opis:
The aim of the paper was to show how cooling of silicone photovoltaic cells influences the amount of electrical energy they produce. The research was conducted both in the laboratory and under real outdoor conditions. Current-voltage characteristics for two different thermal states of PV cells were outlined. Obtained power values for a PV cell working under the influence of refrigerant and without such an influence were compared. As a result of mechanical cooling of PV cells, an increase in photovoltaic cell efficiency was proved.
Celem pracy było wykazanie, w jaki sposób chłodzenie krzemowych ogniw PV wpływa na ilość produkowanej przez nie energii elektrycznej. Badania przeprowadzono w warunkach laboratoryjnych i rzeczywistych. Opracowano charakterystyki prądowo-napięciowe dla różnych stanów termicznych ogniw PV. Porównano wartości pozyskiwanych mocy panelu fotowoltaicznego pracującego bez chłodzenia i z chłodzeniem. Wykazano wzrost wydajności, panelu fotowoltaicznego w wyniku mechanicznego chłodzenia ogniw PV.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2017, 62, 2; 59-63
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka szacowania wartości współczynnika wyrównania temperatury obsypki gruntowej schronu w warunkach pożaru
Methods for estimation of temperature compensation factor of shelter ground cover under fire
Autorzy:
Baryłka, A.
Bąk, G.
Powiązania:
https://bibliotekanauki.pl/articles/210958.pdf
Data publikacji:
2015
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
budownictwo
fizyka budowli
współczynnik wyrównania temperatury
oddziaływanie pożarem
schron wykopowy
civil engineering
physics of building
temperature compensation coefficient
fire action
underground shelter
Opis:
W pracy przedstawiono metodykę poszukiwania średniej wartości współczynnika wyrównania temperatur „a”, który charakteryzowałby właściwości osłonowe gruntowej obsypki stropu schronu wykopowego i umożliwiał prognozę skutków oddziaływania temperatur właściwych pożarowi zewnętrznemu. Za podstawę tej metodyki przyjęto wyniki modelowego badania doświadczalnego i zaproponowano dwie procedury ich interpretacji na podstawie prawa Fouriera. Podstawą pierwszej procedury jest bezpośrednie wykorzystanie różnicowej formy prawa przewodzenia ciepła. Umożliwia ona uzyskanie wartości średniej współczynnika charakteryzującej cały niestacjonarny proces nagrzewu pożarem i stygnięcia obsypki i stropu, ale na pewnym poziomie zagłębienia. Druga procedura wykorzystuje wieloparametryczne podejście identyfikacyjne i umożliwia oszacowanie współczynnika uśrednionego nie tylko w sensie czasowym, lecz także w odniesieniu do całej grubości obsypki.
The paper presents the methods of searching for the average value of the temperature compensation coefficient „a” which would characterize shielding properties of the ground ceiling ballast of the shelter and would allow for prediction of the effects of temperature effects relevant to an external fire. The methods are based on the results of an appropriate laboratory experiment. Two numerical procedures are proposed for interpretation of these results exploiting the Fourier’s law of the heat conduction. The first procedure consists in the direct use of the differential form of this law. It allows us to obtain the value of the average coefficient of non-stationary process characterized by heating with fire and by cooling the ground ceiling ballast but at a certain deep level. The second procedure uses a multiparameter approach enabling the identification and estimation of the averaged ratio not only in time but for the entire thickness of the backfill.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2015, 64, 3; 131-147
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of heat accumulation coefficient for oil bonded moulding sands
Autorzy:
Łągiewka, M.
Konopka, Z.
Zyska, A.
Nadolski, M.
Powiązania:
https://bibliotekanauki.pl/articles/379643.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
theoretical basis
casting processes
moulding material
oil binder
heat accumulation coefficient
moulding sand
temperature equalization coefficient
podstawy teoretyczne
proces odlewniczy
materiał formierski
spoiwo olejowe
współczynnik akumulacji ciepła
masa odlewnicza
Opis:
The possibility of controlling the solidification and cooling time of castings creates prospects of improving their structure and by the same their properties. Thermal properties of the mould constitute therefore an important factor which is necessary to consider while seeking for the mentioned improvement. The presented work illustrates the method of determining some basic thermal coefficients of moulding material, i.e. the coefficient of temperature equalisation a2, known also as the temperature diffusivity, and the heat accumulation coefficient b2, which characterises the ability of moulding material to draw away the heat from a casting. The method consists in experimental determining the temperature field within the mould during the processes of pouring, solidification and cooling of the casting. The performed measurements allow for convenient and exact calculations of the sought-after coefficients. Examinations were performed for the oil bonded moulding sand of trade name OBB SAND ‘E’. The experiment showed that the obtained value of b2 coefficient differs from the value calculated on the basis of theoretical considerations available in publications. Therefore it can be stated that theoretical calculations of the heat accumulation coefficient are thus far not sufficient and not quite reliable, so that these calculations should be verified experimentally.
Źródło:
Archives of Foundry Engineering; 2013, 13, 2; 91-94
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of soil models in the thermodynamic analysis of a submarine pipeline buried in seabed sediments
Autorzy:
Magda, W.
Powiązania:
https://bibliotekanauki.pl/articles/259219.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
submarine buried pipeline
seabed thermal models
shape coefficient
heat transfer coefficient
longitudinal temperature profile
Opis:
This paper deals with mathematical modelling of a seabed layer in the thermodynamic analysis of a submarine pipeline buried in seabed sediments. The existing seabed soil models: a “soil ring” and a semi-infinite soil layer are discussed in a comparative analysis of the shape factor of a surrounding soil layer. The meaning of differences in the heat transfer coefficient of a soil layer is illustrated based on a computational example of the longitudinal temperaturę profile of a -kilometer long crude oil pipeline buried in seabed sediments.
Źródło:
Polish Maritime Research; 2017, 4; 124-130
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simple method to estimate cell wall extensibility coefficient by using only two cardinal numbers
Autorzy:
Pietruszka, M
Powiązania:
https://bibliotekanauki.pl/articles/58740.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Botaniczne
Tematy:
cell wall
plant cell
growing plant
temperature
extensibility coefficient
Opis:
In this short communication we consider the extensibility properties of the cell wall. This is accomplished by a heuristically motivated equation for the expanding volume of the cell. The experimentally determined characteristic time t0 and temperature T0 are the only numbers required for evaluating the effective yielding coefficient Ф(t, T) in the respective time and temperature domains.
Źródło:
Acta Societatis Botanicorum Poloniae; 2009, 78, 4; 269-270
0001-6977
2083-9480
Pojawia się w:
Acta Societatis Botanicorum Poloniae
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies