Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "swimming pool" wg kryterium: Temat


Wyświetlanie 1-40 z 40
Tytuł:
Estimation of solar radiation transmission for polycarbonate retractable swimming pool enclosures
Autorzy:
Zapałowicz, Zbigniew
Garnysz-Rachtan, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1845493.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
outdoor swimming pool
swimming pool roofing system
pool enclosure
polycarbonate enclosure
solar transmission through enclosure
Opis:
Application of retractable enclosures enables to lengthen operation periods for outdoor swimming pools operated in the moderate climate zone. Enclosures allow to diminish energy losses from water in the pool to the environment. Thermal calculations for pools with retractable enclosures are difficult to carry out because of a number of required parameters which can only be estimated. One of them is the transmission of solar radiation through the enclosure. The present paper presents the method of estimation of this parameter for swimming pool enclosures made of polycarbonate panels that have multichannels structure. In order to calculate transmission, the methodology considering the multiples of solar reflection inside the enclosure and their absorption by polycarbonate has been elaborated. Calculation results for transmission of the enclosure were verified experimentally. Analysis of results show that the transmission depends strongly on the enclosure’s construction and on the direction of solar radiation on the enclosure. Mean transmission values of enclosure under research were determined both from calculations and experiment are equal to about 0.69 and 0.64, respectively. However, experimentally determined mean values of total transmission by parallel and perpendicular solar directions in relation to channel axes are equal to about 0.69 and 0.60, respectively.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 129-146
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania żelbetowej konstrukcji basenu z lat 30. XX wieku
Examination of swimming pool concrete structure from beginnings of the 20th century
Autorzy:
Moczko, A.
Dmochowski, G.
Berkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/217776.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Konserwatorów Zabytków
Tematy:
konstrukcja żelbetowa
basen
concrete structure
swimming pool
Opis:
W artykule przedstawiono wyniki badań betonu i zbrojenia oraz rezultaty obliczeń konstrukcji basenu pływackiego z początku XX wieku. W celu określenia stanu technicznego obiektu zrealizowano następujące badania: określenie wytrzymałości betonu w oparciu o badania laboratoryjne próbek pobranych z konstrukcji oraz metodą "pull-out", identyfikację zbrojenia i głębokości powierzchniowej karbonatyzacji betonu. W celu określenia nośności elementów konstrukcyjnych zdefiniowano rzeczywisty model konstrukcji i przeprowadzono obliczenia wytrzymałościowe, wykorzystując dane otrzymane z analiz materiałowych. W podsumowaniu zostały określone wymagania i niezbędne prace, które należy wykonać w celu zapewnienia dalszej bezpiecznej eksploatacji basenu.
The results of concrete and reinforcement examination and structural calculations of swimming pool construction from beginnings of the 20th century are presented in the paper. In order to define technical state of the structure the following examinations were realised: determination of concrete strength basing on laboratory stress analysis and "pull-out" method, identification of reinforcement and surface concrete carbonatisation depth. To determine the bearing capacity of structural elements there was done an identification of construction static model and conducted strength calculations basing concrete data on that obtained from material examination. Finally, there were defined requirements and works necessary to be realised with aim to guarantee further safe exploitation of the swimming pool.
Źródło:
Wiadomości Konserwatorskie; 2009, 26; 108-114
0860-2395
2544-8870
Pojawia się w:
Wiadomości Konserwatorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preduprezhdenie deformacijj i avarijj monolitnykh zhelezobetonnykh bassejjnov
Prevention of deformations and accidents of monolithic reinforced concrete pools
Autorzy:
Kotljar, N.
Poshhina, N.
Likhograjj, V.
Powiązania:
https://bibliotekanauki.pl/articles/78067.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
swimming pool
construction
slab
concrete mix
deformation
accident
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awaria drewnianej szkieletowej konstrukcji ścian basenu kąpielowego
Failure of skeleton timber structure of swimming pool walls
Autorzy:
Malczyk, A.
Brol, J.
Powiązania:
https://bibliotekanauki.pl/articles/161731.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen kąpielowy
budynek basenu
szkielet drewniany
awaria
przyczyna uszkodzeń
swimming pool
swimming pool building
timber frame structure
failure
destruction causes
Opis:
W artykule przedstawiono opis konstrukcji parterowego budynku basenu kąpielowego wykonanego w technologii szkieletu drewnianego. W wyniku błędów projektowych i wykonawczych, po kilku latach użytkowania obiektu wystąpił stan awaryjny konstrukcji nośnej szkieletu spowodowany butwieniem drewna. Przedstawiono sposób wymiany uszkodzonych elementów oraz jego realizację.
Structure of one floor building of swimming pool realized as a skeleton made out of timber is presented. Failure of structure was a result of decay of wood after just few years of exploitation. Paper presents a realization of damage repair.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 7-8, 7-8; 50-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of chloramine concentration in swimming pool water depending on swimming pool intended use
Porównanie stężeń chloramin w wodzie basenowej w zależności od funkcji basenu
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/388965.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
swimming pool water
chloramine
disinfection
woda basenowa
chloraminy
dezynfekcja
Opis:
Swimming pool water is a mixture of supplementary water added to a closed pool circuit (usually from water supply system) and water from a pool basin, constantly purified and disinfected because of its pollution caused by bathing people. In public swimming pools, in accordance with hygiene guidelines, disinfection by chlorine compounds is required. The most commonly used is sodium hypochlorite disinfectant. The disinfectant properties of chlorine are related to its ability to oxidize organic and inorganic compounds, and the result of water chlorination is the formation of disinfection by-products (DBP). Among the most troublesome DBPs for bathers and service facility of the swimming-pool are chloramines. Chloramines are responsible for the so-called syndrome of swimmers irritation, dry skin, irritation of the mucous membranes of the nose, throat and eyes. They give the pool water and the air in the pool hall a characteristic odor and have mutagenic properties. Therefore, analyzing chloramines concentrations and taking actions, in the field of pool water treatment, in order to reduce them are very important. The primary purpose of this paper is to present the distribution of chloramines concentrations (monochloramine and dichloramine) in the pool water, depending on the pool intended use (school training pool, sports pool, pool for children to play, pool with hydromassage and water tunnel). The analysis of the results of research takes into account the swimming pool water treatment systems, exploitation parameters and the number of people bathing. The comparison of parameters (physical, chemical and bacteriological) defining the quality of the pool water, with particular emphasis on the chloramines concentrations, allows to assess the efficiency of the treatment system and the usefulness of the water to swim and bathe in relation to DIN 19643 standards.
Woda basenowa to mieszanina wody uzupełniającej zamknięty obieg basenowy (najczęściej woda z sieci wodociągowej) oraz wody z niecki basenowej, podlegającej ciągłemu procesowi oczyszczania i dezynfekcji z powodu jej zanieczyszczania przez osoby kąpiące się. W basenach publicznych, zgodnie z obowi ązującymi wytycznymi sanitarno-higienicznymi, wymagana jest dezynfekcja związkami chloru. Najczęściej stosowanym dezynfektantem jest podchloryn sodu. Właściwości dezynfekcyjne chloru związane są z jego zdolnością do utleniania związków organicznych i nieorganicznych, a wynikiem chlorowania wody jest powstawanie ubocznych produktów dezynfekcji (DBP). Spośród DBP najbardziej uciążliwymi dla osób kąpiących się i dla obsługi obiektu basenowego są chloraminy. Chloraminy odpowiedzialne są za tzw. zespół podrażnienia u pływaków, suchość skóry, podrażnienia śluzówki nosa, gardła i oczu, nadają wodzie basenowej i powietrzu w hali basenowej charakterystyczny nieprzyjemny zapach i mają właściwości mutagenne. W związku z powyższym analiza stężeń chloramin oraz podejmowanie działań z zakresu technologii wody basenowej, umożliwiających ich zmniejszenie są bardzo ważne. Podstawowym celem badań jest przedstawienie rozkładu stężeń chloramin (monochloraminy i dichloraminy) w wodzie basenowej w zależności od funkcji basenu (szkolny basen do nauki pływania, basen sportowy, basen do zabaw dla dzieci, basen z hydromasażem i tunel wodny). Analiza wyników badań uwzględnia układ oczyszczania wody basenowej, parametry eksploatacyjne oraz obciążenie niecek basenowych. Porównanie parametrów (fizyczno-chemicznych i bakteriologicznych) określających jakość wody basenowej, ze szczególnym uwzględnieniem stężeń chloramin, pozwoliło ocenić sprawność systemu jej oczyszczania i przydatność wody do kąpieli w odniesieniu do normy DIN 19643.
Źródło:
Ecological Chemistry and Engineering. A; 2015, 22, 1; 27-37
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie stężeń chloramin w wodzie basenowej w zależności od funkcji basenu
Comparison of chloramine concentration in swimming pool water depending on function of swimming pool
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/127065.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
woda basenowa
chloraminy
dezynfekcja
swimming pool water
chloramine
disinfection
Opis:
Przedstawiono wyniki badań stężeń chloramin w zależności od funkcji basenu. Zaprezentowano rozkład stężeń chloramin i porównano ich wielkości w wodzie basenowej. Analiza wyników badań uwzględnia układ oczyszczania wody basenowej, parametry eksploatacyjne oraz obciążenie rozpatrywanych niecek basenowych. Porównanie parametrów określających jakość wody basenowej, ze szczególnym uwzględnieniem stężeń chloramin, pozwoliło ocenić przydatność wody do kąpieli w odniesieniu do normy DIN 19643.
The distribution of chloramines concentrations in the pool water, depending on the function of the pool was presented. Analysis of the results of research takes into account the swimming pool water treatment systems, exploitation parameters and the number of people bathing. Comparison of parameters defining the quality of the pool water, with particular emphasis on the chloramines concentrations, allows to assess the usefulness of the water to swim and bath in relation to the DIN 19643 standards.
Źródło:
Proceedings of ECOpole; 2015, 9, 1; 357-363
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of chlorinated water on the development of allergic diseases - an overview
Autorzy:
Kanikowska, A.
Napiórkowska-Baran, K.
Graczyk, M.
Kucharski, M.A.
Powiązania:
https://bibliotekanauki.pl/articles/2081977.pdf
Data publikacji:
2018
Wydawca:
Instytut Medycyny Wsi
Tematy:
asthma
allergic rhinitis
allergic diseases
swimming pool
chlorinated water
Opis:
Indoor swimming pools can be used all year round and serve for one of the most popular sport pursued for recreation The positive effect of swimming arises in particular from the involvement of all the muscles of the body, decreasing the burden on the joints, as well as functional improvement of both the lungs and heart. Chlorine is typically used to disinfect swimming pool water and as a result the changes that take place lead to the formation of by-products, such as monochloramines (NH2Cl), dichloramines (NH2Cl2) i trichloramines (NH2Cl3), trihalogenometans (THM) or haloacetic acid (HAA). The highest concentration of these substances is just above the water surface and they may cause irritation of skin, eyes and mucosa of the respiratory tract. The toxic effect of high chlorine concentration and its side-products on the respiratory system is known, but the effect of low concentrations of these compounds is still not fully determined. Recent studies suggest that development of allergic diseases among swimmers may be increased by epithelial disorders driven by airway barrier dysfunction caused by chlorine irritation. Swimming in chlorinated water may be linked to symptoms of bronchial hyperreactivity, asthma and rhinitis especially in children, elite swimmers and employees of indoor swimming pools. Hypersensivity pneumonitis related to the use of swimming pools may manifest as a swimming pool or sauna user lung, most commonly caused by water polluting pathogens. The article summarizes recent data concerning the influence of chlorinated water on the development of allergic diseases.
Źródło:
Annals of Agricultural and Environmental Medicine; 2018, 25, 4; 651-655
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne aspekty transportu żywych ryb słodkowodnych
Technical aspects of the transport of live freshwater fish
Autorzy:
Chomka, G.
Kasperowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/314761.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
ryba
transport
samochód
basen
fish
transportation
car
swimming pool
Opis:
W artykule przedstawiono problemy związane z transportem żywych ryb. Omówiono również techniczne aspekty umożliwiające samochodowy transport żywych ryb słodkowodnych.
This paper presents the issues related to the transport of live fish. It also discusses the technical aspects of the car modification needed to allow the transport of live freshwater fish.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2013, 14, 10; 69-72
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki oraz możliwości korzystania z pływalni i parków wodnych osób z niepełnosprawnością
Access to swimming pools and water parks and their use by disabled people
Autorzy:
Czeluściński, Wiesław
Kapusta, Robert
Powiązania:
https://bibliotekanauki.pl/articles/1818337.pdf
Data publikacji:
2019-11-27
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
swimming pool
disability
architectural barriers
pływalnia
niepełnosprawność
bariery architektoniczne
Opis:
Spośród wielu form rekreacji ruchowej, która ma ogromny wpływ na poprawę jakości życia, a także rehabilitację zdrowotną osób z niepełnosprawnością, ważną rolę odgrywa kontakt z wodą na pływalniach i w parkach wodnych, które coraz częściej powstają w okolicach wielu miast, osiedli i gmin. Dzięki możliwości korzystania z nich, młodzież i dorośli z różnymi problemami zdrowotnymi mają sposobność rozwijania swych umiejętności pływackich w ramach zajęć sportowych, rekreacyjnych i rehabilitacji ruchowej. Nie wszystkie jednak obiekty są przystosowane dla osób z dysfunkcjami zdrowotnymi, gdyż posiadają bariery architektoniczne, techniczne lub organizacyjne, które ograniczają lub całkowicie uniemożliwiają swobodne korzystanie z nich osobom z różnymi formami niepełnosprawności ruchowej. Dlatego ważnym zadaniem w rozwijaniu zdrowego trybu życia, kultury fizycznej i aktywnej rehabilitacji zdrowotnej jest zapewnienie warunków do korzystania z obiektów sportowych i rekreacyjnych wszystkim osobom, które tego potrzebują.
With their increasing number in and around many cities, but also in towns and villages, swimming pools and water parks are among many forms of recreation. Giving local people access to those facilities has a huge impact on improving the quality of life, as well as on the rehabilitation of people with disabilities. With an opportunity to use them, young people and adults with different health issues have a chance to develop their swimming skills in the context of sports, recreation and rehabilitation. Unfortunately, not all swimming pools or water parks are accessible to persons with disabilities because of architectural, technical or organizational barriers that limit or completely prevent people with various forms of health problems from their free use. Therefore, an important task in developing a healthy lifestyle, physical culture and active rehabilitation is to provide the right conditions for the use of sports and recreational facilities to all people that need them.
Źródło:
Student Niepełnosprawny. Szkice i rozprawy; 2018, 18, 11; 71-84
1689-6416
Pojawia się w:
Student Niepełnosprawny. Szkice i rozprawy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health risk as a consequence of exposure to trihalomethanes in swimming pool water
Autorzy:
Bozym, M.
Wzorek, M.
Klosok-Bazan, I.
Powiązania:
https://bibliotekanauki.pl/articles/872856.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
health risk
toxicological exposure
human exposure
trihalomethane
toxicity
swimming pool
swimming water
Opis:
The article presents the formation and toxicity of trihalomethanes (THMs), substances belonging to Disinfection By- Products (DBP), formed as a result of pool water chlorination. Concentration of THMs in pool water has been standardised in Poland since recently. THMs concentration in pool water depends on multiple factors, mostly the method of water disinfection, including chlorine or organic substance (TOC) concentration. Apart from that, the level of exposure of swimmers to the toxic effect of THMs is affected by their content in the air of swimming pool halls, intensity of swimming as well as time of stay in the indoor swimming pool area. The water and air temperature as well as number of swimmers and time of their staying in pool have also significance influence on THMs concentration. In order to decrease the quantity of THMs in pool water, alternative disinfection agents are applied. Additionally, an efficiently operating pool ventilation system as well as proper water treatment method are also important. Because THMs are produced from organic material under the influence of the chlorination, the users can have an impact on decrease of the THMs concentration in pool water, for instance by taking a shower prior to entering the pool or by wearing a swim cap. The results of studies conducted in 2015 showed that the quantity of THMs in pool water depends on type of the pool (indoor, outdoor), water replacement frequency, water treatment system, chlorine dose and TOC content. In most collected samples, the THMs concentration exceeded the admissible norm (100 μg/L).
W artykule omówiono powstawanie i działanie toksyczne trihalometanów (THM), związków należących do tzw. Disinfection By-Products (DBP), powstających w wyniku chlorowania wody w nieckach basenowych. Od niedawna w Polsce normuje się stężenie tych związków w wodzie basenowej. Stężenie THM w wodach w obiektach basenowych zależy od wielu czynników, głównie od sposobu dezynfekcji wody, w tym stężenia chloru oraz substancji organicznych (TOC). Poza tym na stopień narażenia pływaków na toksyczne działanie THM ma ich zawartość w powietrzu hali basenowych, intensywność pływania oraz czas przebywania na terenie pływalni. Ważna jest też temperatura wody i powietrza oraz ilość osób korzystających z basenu w danym czasie. W celu zmniejszenia ilości THM w wodzie basenowej stosuje się alternatywne środki dezynfekcji. Poza tym ważny jest sprawnie działający system wentylacji hali basenowej i odpowiedni sposób oczyszczania wody. Ponieważ THM są wytwarzane z udziałem substancji organicznych pod wpływem chlorowania, korzystający z basenów mogą wpłynąć na obniżenie poziomu THM, np. poprzez noszenie czepków oraz skorzystanie z prysznica przed wejściem do wody. Przeprowadzone w 2015 roku badania wykazały, że ilość THM w wodzie basenowej zależy od wielu czynników, w tym rodzaju basenu (kryty, odkryty), częstości wymian wody, rodzaju systemu jej oczyszczania, dawki chloru oraz zawartości TOC. W większości pobranych próbek stężenie THM przekraczało dopuszczalną normę (100 μg/L).
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie mikrozanieczyszczeń z makrogrupy PPCPs w wodzie basenowej
The occurence of micropollutants from PPCPs macrogroup in swimming pool water
Autorzy:
Lempart, A.
Kudlek, E.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127547.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mikrozanieczyszczenia
woda basenowa
GC-MS
SPE
micropollutants
swimming pool water
Opis:
Utrzymywanie mikrobiologicznej jakości wody basenowej, mające na celu zahamowania rozprzestrzeniania się zakażeń i chorób, jest priorytetem dla wszystkich właścicieli i zarządców basenów. Istnieje wiele środków dezynfekcyjnych stosowanych w basenach, które mogą potencjalnie powodować produkcję szerokiej gamy ubocznych produktów dezynfekcji (DBP). Mikrozanieczyszczenia te powstają na skutek reakcji z organicznymi i nieorganicznymi substancjami wprowadzanymi na obiekty przez ich użytkowników. Oprócz wielu ubocznych produktów dezynfekcji, w wodzie basenowej współcześnie identyfikowane są również mikrozanieczyszczenia z makrogrupy PPCPs (ang. Pharmaceuticals and Personal Care Products). Przeprowadzone w pracy chromatograficzne analizy jakościowe wody pobranej z niecki basenu szkolnego wykazały obecność ponad 100 różnych mikrozanieczyszczeń, niezidentyfikowanych dotychczas w tym środowisku, m.in. leków, hormonów, witamin, domieszek przemysłowych czy też składników kosmetyków. Do identyfikacji związków zastosowano metodę chromatografii gazowej z detekcją mas GC-MS z jonizacją elektronową poprzedzoną ekstrakcją do fazy stałej SPE (ang. Solid Phase Extraction).
Maintaining the microbial water quality in order to inhibit the spread of infections and diseases is the priority for every swimming pool owners and managers. There is a number of disinfectants that have been used for swimming pool, which potentially produce a wide range of disinfection by-products (DBPs). These micropollutants are produced by reaction with organic and inorganic matter entering swimming pools by their users. Besides DBPs there are many others micropollutants from PPCPs macro group (Pharmaceuticals and Personal Care Products) that are nowadays identified in swimming pool water. This article describes research conducted on the school swimming pool water. Qualitative chromatographic analysis have shown the presence of more than 100 micropollutants that have not been identified in these environment yet, including medicines, hormones, vitamins, industrial admixtures or cosmetic ingredients. Gas chromatography with GC-MS detection and electron ionization followed by SPE (Solid Phase Extraction) was used to identify the compounds.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 169-176
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ARIMA model used to analyze the demand for swimming pool services
Autorzy:
Pawlisiak, Mieczysław
Powiązania:
https://bibliotekanauki.pl/articles/970657.pdf
Data publikacji:
2019-03-31
Wydawca:
Uniwersytet Gdański. Wydział Ekonomiczny
Tematy:
arima model
lifeguarding and water rescue
readiness
swimming pool
swimming baths
safety
Opis:
Na preferencje klientów wybierających aktywną formę spędzania wolnego czasu wpływa wiele czynników. Bogata oferta rynkowa daje szerokie możliwości, a od obiektów sportowych wymaga się, aby pozostawały w pełnej gotowości do świadczenia usług. Pomocne w takim przygotowaniu jest konstruowanie prognoz umożliwiających określenie przewidywalnej liczby klientów. Przykład takiej predykcji, sporządzonej na podstawie pływalni, przedstawiono w niniejszym artykule. W tym celu wykorzystano model ARIMA bazujący na założeniu, że na wartość zmiennej objaśnianej wpływa wartość tej zmiennej opóźniona w czasie.   Klasyfikacja JEL: C2, C22. 
Many factors influence customer preferences among those who choose active leisure. A wide range of market productsmakes for many opportunities, and sports facilities are required to be fully prepared to provide services. It is helpful to create forecasts that enable to determine the predictable number of clients. An example prediction made with respect to swimming pools is presented in this article. For this purpose, the ARIMA model was used, based on the assumption that the value of the endogenous variable is affected by the value of this variable laggedin time. JEL classification: C2, C22. 
Źródło:
Współczesna Gospodarka; 2019, 10, 1 (32); 55-68
2082-677X
Pojawia się w:
Współczesna Gospodarka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chlorine distribution in the indoor and outdoor swimming pools
Rozkład chloru w basenie krytym i otwartym
Autorzy:
Wyczarska-Kokot, Joanna
Lempart, Anna
Dudziak, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/126109.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
indoor swimming pool
outdoor swimming pool
free chlorine
combined chlorine
reliable sampling point
basen kryty
basen otwarty
zawartość chloru
miarodajne punkty poboru próbek
Opis:
The results of research on the distribution of chlorine content in the characteristic points of the outdoor pool (SPO) and indoor pool (SPI) are presented. Sports and recreational pools for swimmers were selected for the study. Technical and technological parameters of these pools are presented. Free chlorine and combined chlorine were the basic parameters affecting the quality of pool water. Their quick and easy estimation allowed to assess the spread of the disinfectant in swimming pools and the effectiveness of its operation. In both swimming pools, there was a large variation in the chlorine content and non-compliance with the requirements in this area (in SPI, content of combined chlorine > 0.3 mg Cl2/dm3, in the SPO content of free chlorine > 0.6 mg Cl2/dm3). In the SPI, in contrast to the SPO, a significant variation in chlorine concentrations was observed in samples taken from various points in the same series. Based on the analysis of the chlorine content in the characteristic points of swimming pools and physio-chemical and bacteriological supplementary parameters, an attempt was made to determine reliable sampling points to assess the quality of water. The test results were compared with the recommendations regarding the quality of swimming pool water.
Przedstawiono wyniki badań nad rozkładem zawartości chloru w charakterystycznych punktach niecek basenu otwartego (SPO) i krytego (SPI). Do badań wybrano baseny o charakterze sportowo-rekreacyjnym, dla osób umiejących pływać. Przedstawiono techniczne i technologiczne parametry tych basenów. Chlor wolny oraz chlor związany były podstawowymi parametrami wpływającymi na jakość wody basenowej. Szybki i łatwy sposób ich oznaczenia pozwolił ocenić rozprzestrzenianie się środka dezynfekcyjnego w nieckach basenowych i skuteczność jego działania. W obu basenach stwierdzono duże zróżnicowanie zawartości chloru i niezgodność z wymogami w tym zakresie (w SPI zawartość chloru związanego > 0,3 mg Cl2/dm3, w SPO zawartości chloru wolnego > 0,6 mg Cl2/dm3). W basenie SPI w odróżnieniu od SPO obserwowano znaczne zróżnicowanie stężeń chloru w próbkach pobranych z różnych punktów w tej samej serii pomiarowej. Na podstawie analizy zawartości chloru w charakterystycznych punktach niecek basenowych oraz uzupełniających parametrów fizyczno-chemicznych i bakteriologicznych podjęto próbę wyznaczenia miarodajnych punktów poboru próbek wody basenowej w celu oceny jej jakości. Wyniki badań porównano z zaleceniami, jakim powinna odpowiadać woda w pływalniach.
Źródło:
Proceedings of ECOpole; 2019, 13, 1-2; 77-84
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the filtration bed type in the pool water treatment system on washings quality
Wpływ rodzaju złoża filtracyjnego w układach oczyszczania wody basenowej na jakość popłuczyn
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Powiązania:
https://bibliotekanauki.pl/articles/126751.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
filter beds
washings
swimming pool
sedimentation
złoża filtracyjne
popłuczyny
basen
sedymentacja
Opis:
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 355-361
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health Risk Assessment of Swimming Pool Users from the Effects of Legionella Spp. Contamination of Water
Autorzy:
Zimoch, Izabela
Paciej, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/124346.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
Legionella spp.
swimming pool
health risk assessment
GIS technology
water quality control
Opis:
One of the main problems in the scope of public health is poor identification of the waterborne diseases and their etiology. One of the aims of the new directive concerning the quality of water intended for human consumption is to implement the principles of hazard assessment in water supply systems (WSS) in the member states, on the basis of water quality monitoring and analyses of the system functioning conditions. The implementation of risk management procedures in WSSs is to ensure an increase in the water supply safety and, in turn, protect the consumer’s health against the harmful effects of any potable water contamination. At present, the secondary legislation to the Polish acts implementing the Directive of the Council of Europe is the Regulation of the Minister of Health on the quality of water intended for human consumption, which also sets forth the scope of monitoring the quality of hot water for Legionella spp., which can be an etiological factor of legionellosis. Another act regulating the water quality in terms of Legionella spp. is the Regulation of the Minister of Health on water quality in swimming pools. These acts, referring to the parameter of Legionella spp., are complementary. This paper presents the results of evaluating the change in the sanitary status of hot water quality in terms of contamination with Legionella spp. bacteria in the selected swimming pool facilities in southern Poland (Silesian Voivodship). On the basis of the available water quality test from state inspections (Chief Sanitary Inspectorate), an analysis of the microbiological quality of hot water in swimming pools was conducted. The analyses included a spatial distribution of those facilities, which results from the regionalisation subject to the territorially competent public health authority exercising supervision over the water quality in the Silesian Voivodship. The methods were presented for determination of the health risk of swimming pool users as a result of contamination of swimming pool water with Legionella spp. in relation to the availability of a given recreation facility. The final result of these studies is the use of GIS (Geographic Information System) tools in spatial risk interpretation.
Źródło:
Journal of Ecological Engineering; 2020, 21, 2; 178-189
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the phytotoxicity of filter backwash water coagulation products from a pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/207079.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phytotptpxicity
swimming pool water
coagulation process
Lepidium sativum
Lemna minor
fitotoksyczność
woda basenowa
proces koagulacji
Opis:
The possibility of using the process of coagulation for purifying the filter backwash water from a swimming pool water system has been presented. The assessment of the process efficiency based on the physicochemical parameters was extended by a phytotoxicity analysis of products (sludges and supernatant liquids) obtained from the coagulation processes. The phytotoxicity of sludges was examined with respect to garden cress (Lepidium sativum) and white mustard (Sinapis alba), while duckweed (Lemna minor) was used for studying liquids. Coagulation process was highly effective in purifying backwash water when the lowest of the studied aluminum coagulant doses (from 7 to 20 mg/dm3) was used. Moreover, the phytotoxicity assessment of backwash water allowed the determination of the hazard toward plants, which would be posed by using the backwash water for plant irrigation. The high stimulation of the growth of plant indices, observed in samples with raw backwash water, was caused by nutritive nitrogen and phosphorus. Their removal, in the case of postcoagulation solutions, significantly contributed to the inhibition of plant growth. In turn, sludges derived from both raw washings and coagulation exhibited phytotoxicity.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 43-56
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania możliwości zagospodarowania popłuczyn z obiegów basenowych
The study of possibilities of washings reusing from swimming pool circulation systems
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125784.pdf
Data publikacji:
2015
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
popłuczyny
obieg basenowy
zagospodarowanie popłuczyn
sedymentacja
washings
swimming pool water circulation system
washings reusing
sedimentation
Opis:
Baseny to bardzo drogie pod względem eksploatacji obiekty sportowe, dlatego też osoby zarządzające tymi obiektami szukają sposobów na obniżenie kosztów ich użytkowania. Jednym z nich jest zagospodarowanie popłuczyn dotychczas odprowadzanych do kanalizacji sanitarnej. Oceny możliwości zagospodarowania popłuczyn odprowadzanych z filtracyjnych instalacji basenowych dokonano na podstawie dopuszczalnych wartości podstawowych wskaźników zanieczyszczeń w ściekach odprowadzanych do wód i ziemi (pH temperatura, zawiesiny ogólne, ChZT, BZT5, Pog, Nog, chlor wolny). Badania jakości popłuczyn z 26 basenów wykazały, że ich jakość jest zależna od warunków eksploatacji danego obiegu basenowego, m.in. długości cyklu filtracyjnego i rodzaju złoża. Parametrami uniemożliwiającymi bezpośrednie zagospodarowanie popłuczyn były zbyt duża zawartość zawiesin ogólnych (≥ 35 mg/dm3) oraz stężenie chloru wolnego (≥ 0,2 mg Cl2/dm3). Jakość wód nadosadowych powstałych w wyniku sedymentacji popłuczyn wskazuje na ich przydatność do zagospodarowania. Zastosowanie w obiektach basenowych odstojników popłuczyn umożliwiłoby odciążenie systemów kanalizacji i odpływ wód nadosadowych do wód powierzchniowych lub ich wykorzystanie do nawadniania terenów zielonych w sposób bezpieczny dla środowiska.
Swimming pools are very expensive in terms of exploitation sports facilities, therefore managers of these facilities are looking for methods of reducing the costs of their use. One of the proposed method is the managing of washings previously discharged to the sanitary sewage system. The assessment of possibilities of washings reusing from swimming pool filtration system is based on the limits of basic indicators of pollutants in wastewater discharged to water and soil (temperature, pH, TSS, BOD5, COD, TN, TP, free chlorine). The conducted research of washings quality from 26 tested swimming pools have shown that washings quality is dependent on the operating conditions of the circuit pool, including the filter cycle duration and types of filter bed. The parameters which prevents direct management washings were too high content of total suspended solids (≥ 35 mg/dm3) and the concentration of free chlorine (≥ 0.2 mg Cl2/dm3). Quality washings subjected to sedimentation indicates its usefulness for rational management. The application in swimming pools settling tanks allows discharge sewage systems and drainage supernatants to surface waters or using to irrigation green areas in an environmentally safe way.
Źródło:
Proceedings of ECOpole; 2015, 9, 2; 803-813
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of solar collectors on the example of a water-park. Part 1: Technical analysis
Wykorzystanie kolektorow slonecznych na przykladzie parku wodnego. Cz. 1: Analiza techniczna
Autorzy:
Tucki, K.
Powiązania:
https://bibliotekanauki.pl/articles/793132.pdf
Data publikacji:
2016
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
solar collector
technological analysis
modernization
energy system
water park
heating system
swimming pool
venting system
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2016, 16, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości zrzutu popłuczyn z obiektu basenowego do rzeki
Analysis of the possibility of washings discharge from the swimming pool to the river
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/127336.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
basen
popłuczyny
klasa czystości rzeki
sedymentacja
koagulacja
swimming pool
washings
cleanliness class of river
sedimentation
coagulation
Opis:
W pracy przedstawiono wyniki badań, na podstawie których określono możliwość odprowadzenia popłuczyn, powstałych w wyniku płukania złóż filtracyjnych w systemie oczyszczania wody basenowej, do pobliskiej rzeki. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono stopień ich zanieczyszczenia. Wyniki badań porównano z zaleceniami dotyczącymi dopuszczalnego stopnia zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800) i wymaganiami pozwolenia wodnoprawnego wydanymi dla analizowanego obiektu basenowego. Analiza wyników badań popłuczyn surowych (niepoddanych obróbce) wykazała, że bezpośrednie ich odprowadzenie do rzeki jest niemożliwe przede wszystkim ze względu na duże stężenie chloru wolnego oraz ilość zawiesin ogólnych. Analiza wyników badań popłuczyn poddanych procesowi sedymentacji lub koagulacji objętościowej w warunkach laboratoryjnych pozwoliła zaprojektować system odprowadzenia wody nadosadowej do rzeki. Warunkiem „zrzutu” wody nadosadowej do rzeki będzie konieczność zastosowania zbiornika buforowego, osadnika lub systemu wspomagającego sedymentację zawiesin w popłuczynach np. poprzez zastosowanie koagulacji objętościowej, a następnie odprowadzanie zagęszczonych ścieków do kanalizacji sanitarnej.
The paper presents the results of studies on determining of the possibility of discharge washings, as a result of rinse filter beds in the swimming pool water treatment system, to the river. Based on the physical and chemical analysis of washings samples the degree of their contamination was determined. The results were compared with the recommended acceptable level of pollutants in wastewater discharged to water or soil (OJ 2014, item 1800) and with the requirements of the water permit issued for the analyzed swimming pool. The obtained results for raw washings (untreated) showed that direct discharge of washings into the near located river is impossible, especially due to the high concentration of free chlorine and the amount of total suspended solids (TSS). Analysis of the results of washings subjected to the process of sedimentation or coagulation in the laboratory helped design the system supernatant water drain into the river. The condition of such management would be to use a buffer tank, settling tank or supporting system to sedimentation of suspended solids, e.g. the use of coagulation and then the draining of concentrated sewage into the sanitary sewage system.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 325-331
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltration for Purification and Treatment of Water Streams in Swimming Pool Circuits
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125442.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
swimming pool water
pressure driven
membrane processes
closed circuit
water systems
water treatment systems
water recovery
Opis:
The paper presents possible applications of pressure-driven membrane processes for treatment of swimming pool water and purification of waste streams – washings. Newly identified swimming pool water quality issues are presented that require a modernization of existing technologies. The studies used polymer membranes with the same particle distribution range (50000 Da), but made of different membrane-forming materials: polyvinylidene difluoride (PVDF) and polyether sulfone (PES) for purification of washings. The ultrafiltration process allowed obtaining a high turbidity reduction rate in washings (over 95%), and also a significant reduction of total organic carbon. The effectiveness of the PES membrane was reduced after the process commencement, whereas the separation capacity of the PVDF membrane increased during the studied filtration process. While setting the operational process parameters consideration should be given also to the resistance of used membranes to chlorine present in the swimming pool water. A prolonged exposure of the polyether sulfone membrane to chloride may have caused its gradual damage and degradation of its separation properties.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 38-44
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna żelbetowej konstrukcji basenu sportowego
Numerical analysis of the reinforced concrete structure of a sports pool
Autorzy:
Skierka, Beata
Domski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2081886.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
konstrukcja żelbetowa
analiza numeryczna
obciążenie
modernizacja
swimming pool
reinforced concrete structure
numerical analysis
load
modernization
Opis:
W artykule przedstawiono analizę numeryczną istniejącego basenu. Analiza obejmowała trzy warianty obciążeniowe związane z jego modernizacją. Pierwszy przypadek obciążeń dotyczył rzeczywistej pracy basenu przed modernizacją. Natomiast dwa kolejne przypadki obciążeń obejmowały możliwe oddziaływania na basen po modernizacji. W wyniku przeprowadzonych analiz stwierdzono, że modernizacja basenu związana ze zmianą jego obciążenia, nie spowoduje przekroczenia jego stanów granicznych.
The article presents the numerical analysis of the existing swimming pool. The analysis included three load variants related to the pool modernization. The first load case was related to the actual operation of the pool before its modernization. Next, two subsequent load cases included possible impacts on the swimming pool after its modernization. As a result of the conducted analyzes, it was found that the modernization of the swimming pool will not result in exceeding its limit states.
Źródło:
Przegląd Budowlany; 2022, 93, 3-4; 89--94
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Disinfection By-Products in Swimming Pool Water and Possibilities of Limiting Their Impact on Health of Swimmers
Produkty uboczne dezynfekcji wody basenowej i możliwości ograniczania ich wpływu na zdrowie użytkowników
Autorzy:
Ratajczak, Katarzyna
Piotrowska, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/385396.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
uzdatnianie wody basenowej
THM
produkty uboczne dezynfekcji wody
wentylacja
treatment of swimming pool water
DBPs
ventilation
Opis:
Obecność produktów ubocznych dezynfekcji wody (DBPs) w środowisku basenowym jest zagrożeniem dla zdrowia użytkowników pływalni. Z uwagi na mechanizm formowania DBPs nie jesteśmy w stanie zapobiec ich powstawaniu. Istnieje jednak kilka możliwości zapobiegania szkodliwemu wpływowi DBPs na zdrowie użytkowników basenów, wśród których należy wymienić różne rodzaje metod redukcji prekursorów chloru związanego i DBPs oraz nowe podejście do projektowania rozdziału powietrza wentylacyjnego.
The presence of water disinfection by-products (DBPs) in the pool environment is a threat to the health of the users of swimming pools. Due to the mechanism of DBP formation, we are not able to prevent their presence. However, there are several ways to prevent the harmful effects of DBPs on the health of pool users; among these, various kinds of methods that result in the reduction of combined chlorine and DBPs precursors should be mentioned. And last but not least, a new approach to the design of the ventilation system for indoor swimming pools seems to be crucial for the above-mentioned purpose.
Źródło:
Geomatics and Environmental Engineering; 2019, 13, 3; 71-92
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geotermia na przykładzie tarnowskich term w Tarnowie Podgórnym
Geothermics on the example of tarnowskie termy in Tarnowo Podgórne
Autorzy:
Trzepierczyński, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/115283.pdf
Data publikacji:
2018
Wydawca:
Wyższa Szkoła Techniczna w Katowicach
Tematy:
geotermia
dolna jura
basen sportowo-rekreacyjny
perspektywy geotermii
geothermics
Lower Jurassic
competition and recreation swimming pool
perspectives
Opis:
Polska posiada największe zasoby energii geotermalnej względem innych rodzajów energii odnawialnej. Energia geotermalna jest niezależna od warunków klimatycznych i atmosferycznych. Z końcem ubiegłego wieku w naszym kraju rozpoczęto prace badawcze poszukiwania i oszacowania zasobów wód geotermalnych, wskazano perspektywy ich wykorzystania oraz rozpoczęto budowę zakładów geotermalnych. Autor artykułu opracował możliwości pozyskania energii wód geotermalnych dla celów rekreacyjno-balneologicznych dla Tarnowa Podgórnego w Wielkopolsce. Na podstawie badań geologicznych autora wykonano projekt wiercenia, następnie dokumentację hydrogeologiczną, zaprojektowano i wybudowano ośrodek rekreacyjny Tarnowskie Termy otwarty w maju 2015 r. W artykule wskazano na rolę wyprzedzających badań geologicznych dla efektów poszukiwania wód geotermalnych. W Tarnowie Podgórnym nawiercono w utworach dolnojurajskich na głębokości 810-1170 m p.p.t. wodę geotermalną o wydajności 220m3/h, temperaturze 44°C i mineralizacji 80g/l. Tarnowskie Termy to 2 baseny geotermalne wewnętrzny i zewnętrzny, basen rekreacyjny oraz basen sportowy i do nauki pływania. Woda chlorkowo-sodowa z zawartością pierwiastków: J, Ba, Mg, Ca, F, Cu, Fe stwarza perspektywy do rozwoju balneologii. Dziennie w Tarnowskich Termach przebywa około 1500 ludzi. Obecnie po pewnym zastoju nastąpił w naszym kraju wzrost zainteresowania wykorzystaniem energii geotermalnej dla ciepłownictwa, rekreacji a nawet produkcji energii elektrycznej. Przełamano zastój budowy zakładu geotermalnego w Toruniu oraz zatwierdzono do realizacji wykonanie odwiertów geotermalnych na Podhalu, w Kole, Lądku Zdroju, Sochaczewie i Sieradzu. Problematykę wykorzystania energii geotermalnej powinno się również reaktywować w Górnośląskim Zagłębiu Węglowym.
Great resources of geothermal energy in relation to other types of renewable energy there are in Poland. Geothermal energy is independent of climate and weather conditions. At the end of the past century, research for geothermal water condition and construction of geothermal plants were started in our country and then, their resources were estimated and the options of their use were determined. Possibilities for acquisition of geothermal water energy for recreation and balneology purposes in Tarnowo Podgórne in Wielkopolska Region of Poland were presented in this article. On the basis of the author's geological research, project of drilling and hydrogeological documents were prepared and then, the recreation centre "Tarnowskie Termy" was designed and built. Opening of the centre took place in May 2015. The article points out the role of leading geological research for the effects of searching for geothermal water. Geothermal water with the flow rate of 220m3/h, 44°C of temperature and 80g/l mineralization was extracted in Tarnowo Podgórne in Lower J urassic formations at the depth of 810-1170 m b.g.l. Tarnowskie Termy consist of 2 geothermal pools - an indoor and an outdoor pool, a pool for recreation swimming, a competition pool and a pool for learning swimming. Sodium chloride water with I, Ba, Mg, Ca, F, Cu, Fe elements provides perspectives for development of balneotherapy. Each day, 1,500 people spend time in Tarnowskie Termy. Currently, after some stagnation, a growth of interest in using geothermal energy for heat engineering, recreation and even electrical energy production has been observed in our country. The construction of geothermal plant in Toruń was resumed, and drilling of geothermal boreholes in Podhale, Koło, Lądek Zdrój, Sochaczew and Sieradz was accepted for accomplishment. The question of geothermal energy use should be also revived in Upper Silesian Coal Basin.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach; 2018, 10; 49-63
2082-7016
2450-5552
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Technicznej w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the possibility of recycling backwashing water from the swimming pool water treatment system
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/388489.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
swimming pool water
backwashing
toxicological assessment
physicochemical analysis
biotests
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
Opis:
The paper presents the physicochemical analysis and toxicological assessment of backwashing samples taken after the process of washing filter beds in a raw condition after the process of their aeration and dechlorination. The backwash water under investigation originated from circulation systems existing in two indoor swimming pool facilities. The backwash water, as used at the preliminary and the main stages, was characterized by different physicochemical properties. For toxicological assessment, the Mictorox® bioluminescence inhibition test, the Chaoborus sp. insect larva survival test and the phyto test using Lemna minor fine cilium were involved. The investigation presented in the paper included a preliminary phase focusing on the ecotoxic characterization of backwash water subjected to aeration and dechlorination processes. In turn, at the main stage, the effect of aeration duration on the quality of backwash water in terms of its physicochemical parameters was analyzed. The results of the preliminary stage investigation indicate that backwash water, both in a raw condition and after 30 minutes’ aeration, could not be discharged directly to the environment due to the threat to living organisms caused by its high toxicity. Whereas, using 160 minutes’ aeration duration contributed to a significant improvement in the quality of the backwash water and elimination of its toxic properties with respect to the indicator organisms used. The chemical dechlorination process brought about varying effects. In the case of the Microtox® test, a stimulation of bacterial bioluminescence was noted, but, at the same time, the death of individual insect larva specimens was observed. In spite of the high biomass increase in the Lemna minor test, a gradual discolouration of fronds under the influence of backwash water was observed. Because of the presence of numerous compounds being disinfection by-products, as well as coagulant residues in backwash water deriving from swimming pool systems, it is necessary to seek further solutions that will allow them to be recycled, which will result in a reduction of water consumption and effluent discharges.
W pracy przedstawiono analizę fizykochemiczną oraz ocenę toksykologiczną próbek popłuczyn pobranych po procesie płukania złóż filtracyjnych w stanie surowym po procesie napowietrzania oraz dechloracji. Badane popłuczyny pochodziły z obiegów zlokalizowanych w dwóch obiektach basenowych krytych. Do oceny toksykologicznej włączono test inhibicji bioluminescencji Mictorox®, przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania obejmowały fazę wstępną, skupiającą się na charakterystyce ekotoksykologicznej popłuczyn poddanych procesom dechloracji oraz napowietrzania. W etapie zasadniczym badań analizowano dodatkowo wpływ czasu napowietrzania na jakość popłuczyn pod względem parametrów fizykochemicznych. Wyniki wstępnego etapu badań sygnalizuj ą, że popłuczyny zarówno w stanie surowym, jak i po 30-minutowym napowietrzaniu nie mogły zostać bezpośrednio odprowadzone do środowiska ze względu na zagrożenie dla organizmów żywych, spowodowane ich wysoką toksycznością. Natomiast zastosowane wydłużenie czasu napowietrzania (160 min) przyczyni ło się do znaczącej poprawy jakości popłuczyn i pozbawienia ich właściwości toksycznych w stosunku do wykorzystanych organizmów wskaźnikowych. Zróżnicowane efekty przyniósł zabieg chemicznej dechloracji. W przypadku testu Microtox® odnotowano stymulację bioluminescencji bakterii, równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem użytych popłuczyn. Niezbędne jest poszukiwanie dalszych rozwiązań umożliwiających ich recykling, co zapewni ograniczenie zużycia wody oraz odprowadzania ścieków.
Źródło:
Ecological Chemistry and Engineering. A; 2016, 23, 4; 401-410
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jubileusz 65 lat działalności pływalni w Pałacu Młodzieży w Warszawie
65-year jubilee of swimming pool in the Palace of Youth in Warsaw
Autorzy:
Krynicki, Bartłomiej
Pawlikowska-Piechotka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2044434.pdf
Data publikacji:
2021
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
historia architektury
historia sportu
PKiN Warszawa
pływalnia
history of architecture
history of sport
PKiN Warsaw
swimming pool
Opis:
Pałac Młodzieży w Warszawie został oddany do użytku 65 lat temu, w kwietniu 1955 r., jako część gmachu Pałacu Kultury i Nauki, wzniesionego w stylu socrealizmu. Był wówczas niezwykłą atrakcją, oferując dzieciom nieosiągalne gdzie indziej możliwości rozwoju pasji i zainteresowań. Na przykład, kryta pływalnia w Pałacu Młodzieży była i jest nadal jedyną pływalnią w województwie mazowieckim, na której jest możliwe uprawianie skoków do wody. Jest to jednocześnie jedna z kilku pływalni w Polsce, na której można uprawiać tę dyscyplinę w pełnym zakresie konkurencji przez cały rok. W 2007 r. wpisano Pałac Kultury i Nauki wraz z otoczeniem (Plac Defilad) do rejestru zabytków. Prace modernizacyjne, które miały miejsce w Pałacu Młodzieży, w tym na pływalni PM-PKiN, musiały uwzględnić bardzo restrykcyjne i szczegółowe rekomendacje programu konserwatorskiego, narzucającego zachowanie historycznych walorów stylu architektonicznego pływalni. Oddana w 2016 r. ponownie do użytku po zabiegach renowacyjnych pływalnia w PM-PKiN służy obecnie sekcji pływackiej (zajęcia: piłka wodna, skoki do wody, pływanie, aerobik).
The Palace of Youth in Warsaw was opened 65 years ago, in April 1955, as a part of the Palace of Culture and Science building (PKiN), erected in the style of socialist realism. At that time, it was an extraordinary attraction, offering children unattainable elsewhere opportunities to develop their passions and interests. For example, the indoor swimming pool at the Palace of Youth was (and still is) the only swimming pool in the Masovian Voivodeship where diving is possible. At the same time, it is one of the few swimming pools in Poland where this discipline can be practiced in the full range of competition throughout the year. In 2007, the Palace of Culture and Science and its surroundings (Parade Square) entered into the register of historic monuments. The modernization works that took place in the Palace of Youth, including PM-PKiN swimming pool, had to take into account very restrictive and detailed recommendations of the conservation program, which imposed preservation of the historical values of architectural style of the swimming pool. The swimming pool at PM-PKiN, which was reopened in 2016 after renovation, is now used by the swimming section (activities: water polo, diving, swimming, aerobics).
Źródło:
MAZOWSZE Studia Regionalne; 2021, 37; 131-152
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125768.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
integrated process
washings nanofiltration
coagulation
swimming pool water installation
Opis:
Przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu: koagulacja-sedymentacja-nanofiltracja do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5-3,0 mg Al/dm3) oraz sedymentacji (przy czasie trwania 0,5-24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mg Al/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Cząsteczki osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, przy wyższej dawce koagulantu (3,0 mg Al/dm3), równocześnie spowodowały stopniowy wzrost zdolności separacyjnych membrany i utworzenie tzw. membrany wtórnej. Przy czym charakteryzowała się ona mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5-3.0 mg Al/dm3 and sedimentation where the scope of duration 0.5-24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mg Al/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after Edyta Łaskawiec, Mariusz Dudziak i Joanna 184 Wyczarska-Kokot coagulation with dose 3.0 mg Al/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 177-184
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt konstrukcji przekrycia pływalni miejskiej
Design of the shell roof structure of the swimming pool
Autorzy:
Sęk, Anna Małgorzata
Prusiel, Jolanta Anna
Powiązania:
https://bibliotekanauki.pl/articles/162085.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
pływalnia publiczna
przekrycie dachowe
przekrycie cienkościenne
powłoka walcowa
obliczenia statyczne
analiza statyczno-wytrzymałościowa
metoda numeryczna
metoda analityczna
swimming pool
public swimming pool
roof cover
thin-walled covering
cylindrical shell
static calculations
static-strength analysis
numerical method
analitycal method
Opis:
Opracowano koncepcję architektoniczną obiektu pływalni miejskiej z dwoma wariantami konstrukcji przekrycia w postaci powłoki walcowej. Przeprowadzono analizę porównawczą sił wewnętrznych w powłoce uzyskanych metodą numeryczną i analityczną. Zwymiarowano żelbetową konstrukcję przekrycia powłokowego zgodnie z obowiązującymi eurokodami.
The architectural and construction concept of the swimming pool with two types of cylindrical shell roof was designed. A comparative analysis of internal forces using a numerical and analytical method has been carried out. The reinforced structure of cylindrical shell roof has been designed according to required eurocodes.
Źródło:
Przegląd Budowlany; 2020, 91, 5; 43-48
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/387996.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
integrated process
washings nanofiltration
coagulation
sedimentation
swimming pool water
Installation
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
Opis:
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 227-236
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Pool Detergents on Formation of Chloramines in Swimming Pool Water
Wpływ środków czystości stosowanych na pływalniach na powstawanie chloramin w wodzie basenowej
Autorzy:
Stańkowska, Emilia
Włodyka-Bergier, Agnieszka
Bergier, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/385964.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
produkty uboczne dezynfekcji wody
chloraminy
środki czystości
chemia basenowa
woda basenowa
disinfection by-products
chloramines
cleaning detergents
pool chemistry
swimming pool water
Opis:
Środki czystości stosowane na pływalniach są istotnym elementem w procesie utrzymywania należytych warunków sanitarno-higienicznych. Mogą być również przyczyną zanieczyszczenia wody, a także stanowić potencjalne zagrożenie zdrowotne dla użytkowników pływalni. Badania naukowe pokazują, że połączenie substancji stosowanych podczas dezynfekcji z niektórymi zanieczyszczeniami wody basenowej może powodować powstawanie wielu groźnych produktów ubocznych. Jednym z nich są chloraminy wykazujące właściwości kancerogenne i mutagenne. Analiza czynników mających wpływ na ich powstawanie jest zatem bardzo ważna. Celem artykułu było określenie wpływu środków czystości stosowanych na pływalniach na powstawanie chloramin w wodzie basenowej. Próbki wody basenowej poddawano działaniu wybranych detergentów (Benamin AKR, Benamin SND, Randklar A, Randklar S), używanych na jednej z krakowskich pływalni, następnie badano je pod kątem zawartości monochloraminy, dichloraminy i trichloraminy. Otrzymane wyniki mogą być pomocne przy podejmowaniu działań łagodzących negatywne skutki używania środków czystości na basenach.
Cleaning agents used in swimming pools are essential elements in maintaining the proper hygiene of a swimming pool facility. They can also pollute water and cause a potential health hazard for swimming pool users. Studies show that the combination of substances used for disinfection with some contaminations presented in pool water can cause the formation of many dangerous by-products. One of these is chloramines, which have carcinogenic and mutagenic properties; this is why an analysis of the factors that influence their formation is very important. The purpose of this article is to determine the effect of pool detergents used on swimming pools on the formation of chloramines in pool water. Samples of swimming pool water were treated with selected detergents (Benamin AKR, Benamin SND, Randklar A, and Randklar S) used in one of Krakow’s public swimming pools and then tested for monochloramine, dichloramine, and trichloride. The results may be helpful in taking the steps to mitigate the negative effects of using cleaning agents.
Źródło:
Geomatics and Environmental Engineering; 2019, 13, 3; 93-102
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości bakteriologicznej i fizyczno-chemicznej wody basenowej w wybranym krytym obiekcie rekreacyjnym
Assessing bacteriological and physicochemical quality of swimming pool water in an indoor recreational object
Autorzy:
Szczygłowska, R.
Chyc, M.
Burzała, B.
Kołwzan, B.
Powiązania:
https://bibliotekanauki.pl/articles/236846.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
kryty basen
jakość wody
dezynfekcja
Pseudomonas aeruginosa
mętność
potencjał redoks
turbidity
swimming pool
water quality
disinfection
redox potential
Opis:
Jakość wody w krytych obiektach rekreacyjnych (pływalnie, SPA, parki wodne) ma bardzo istotne znaczenie zdrowotne. Niewłaściwie prowadzony proces dezynfekcji wody basenowej może powodować zakażenia bakteriologiczne, przy czym stosowanie środków dezynfekcyjnych w nadmiernych ilościach może również powodować schorzenia u ludzi. W pracy dokonano oceny jakości wody w wybranej pływalni na podstawie rutynowej oraz rozszerzonej analizy mikrobiologicznej i fizyczno-chemicznej. Wykazano, że rutynowa analiza mikrobiologiczna wody basenowej nie pozwala na prawidłową ocenę jej stanu sanitarnego. Rutynowe wskaźniki mikrobiologiczne osiągnęły bowiem poziom potwierdzający zadowalającą jakość wody w odniesieniu do prawie wszystkich punktów pomiarowych badanego obiektu. Wyjątek stanowiły wanny SPA oraz brodzik dla dzieci, gdzie odnotowano jedynie ponadnormatywną liczbę bakterii mezofilnych (115÷1000 jtk/cm3). Jednak dopiero rozszerzona analiza mikrobiologiczna wody pozwoliła na wykrycie obecności bakterii z rodzaju Pseudomonas, w tym Pseudomonas aeruginosa. Badane próbki wody charakteryzowały się także niższą wartością potencjału redoks (507÷582 mV) oraz mniejszą zawartością chloru wolnego (0÷0,1 gCl2/m3). Jedną z przyczyn okresowego pojawiania się bakterii Pseudomonas był zastój wody w elementach instalacji, w których następował rozwój tych bakterii w ilościach przekraczających 100 jtk/cm3, a także gronkowców koagulazododatnich. Bakterie z rodzaju Pseudomonas obecne były również w próbkach wody pochodzących z urządzeń do jej rozdeszczania. Otrzymane wyniki wykazały możliwość zasiedlania urządzeń basenowych - w przypadku niewłaściwie prowadzonego procesu dezynfekcji - przez mikroorganizmy stanowiące zagrożenie dla zdrowia użytkowników obiektów rekreacyjnych.
Water quality in indoor recreational objects (swimming pool, SPA, aquapark) is of paramount importance to the health of the users. Inadequate disinfection of swimming pool water may be the underlying cause of various diseases or afflictions. In the recreational object chosen for the study reported on here, water quality assessments were carried out using routine and extended microbiological and physicochemical analyses. It has been demonstrated that routine microbiological analysis failed to reliably assess the sanitary condition of the swimming pool water. In terms of routine microbiological indicators, water quality was satisfactory at all sampling sites but two. The two exceptions were in the SPA tubs and wading pools, where mesophilic bacteria alone were found to occur in excessive numbers (115 to 1000 cfu/cm3). Only with extended microbiological analysis was it possible to detect the occurrence of bacteria of the Pseudomonas genus, including Pseudomonas aeruginosa. The water samples examined in this mode also displayed lower redox potential values (507 to 582 mV) and a lower free chlorine content (0 to 0.1 gCl2/m3). The periodical occurrence of Pseudomonas bacteria should, inter alia, be attributed to the stagnation of water in some parts of the installation, where their growth rate was found to exceed 100 cfu/cm3, and where the presence of coagulase-positive staphylococci was detected. Pseudomonas bacteria were also present in the water samples collected from spray irrigators and rain showers. The results obtained make it clear that if the disinfection process is conducted without sufficient efficacy, the microorganisms growing in the swimming pool develop the potential for colonizing the installations, and thus pose health hazards to the swimmer.
Źródło:
Ochrona Środowiska; 2012, 34, 4; 51-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Evaluation of the recycling possibility of washings from swimming poool water treatment system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/126852.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
swimming pool water
back washing water
toxicological assessment
physicochemical analysis
Opis:
Przedstawiono ocenę fizykochemiczną oraz toksykologiczną próbek popłuczyn surowych (pobranych bezpośrednio po procesie płukania złóż filtracyjnych) po procesie napowietrzania oraz procesie dechloracji. Popłuczyny pobrano z obiegów basenowych dwóch krytych pływalni. Przeprowadzono badania wstępne i zasadnicze, w których popłuczyny charakteryzowały się zróżnicowanymi parametrami fizykochemicznymi. Do oceny toksykologicznej zastosowano test inhibicji bioluminescencji Mictorox®, test przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania wstępne obejmowały charakterystykę ekotoksykologiczną popłuczyn poddanych procesom napowietrzania oraz dechloracji. W badaniach zasadniczych analizowano wpływ czasu napowietrzania na jakość popłuczyn. Wyniki badań wstępnych wskazywały, że popłuczyny surowe, jak również po 30-minutowym napowietrzaniu nie mogły być bezpośrednio odprowadzone do środowiska naturalnego ze względu na wysoką toksyczność w stosunku do organizmów żywych. Zastosowanie dłuższego czasu napowietrzania (160 minut) przyczyniło się do znacznej poprawy jakości popłuczyn i eliminacji ich właściwości toksycznych w stosunku do organizmów wskaźnikowych. Zróżnicowane efekty uzyskano po procesie chemicznej dechloracji. Odnotowano stymulację bioluminescencji bakterii (testu Microtox®), ale równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem popłuczyn. Ze względu na zmienność jakości popłuczyn, obecność w nich ubocznych produktów dezynfekcji i koagulacji oraz toksyczne oddziaływanie na organizmy niezbędne jest rozszerzenie badań w zakresie metod umożliwiających ich recykling.
This study discusses the physical and chemical analysis as well as toxicological evaluation of backwashings samples collected after rising raw filter beds, following aeration and dechlorination process. The tested washings were collected at facilities located in two indoor swimming pools. Toxicological evaluation included Mictorox® bioluminescence inhibition assay, Chaoborus sp. larvae survivability test as well as Lemna minor duckweed fito test. The initial stage of the research was focused on eco-toxicological properties of backwashings, subject to aeration and dechlorination processes. The main stage of the research involved additional analysis of the impact of aeration duration on the quality of washings in terms of physical and chemical parameters. The results of the initial stage clearly suggest that both raw washings as well as washings after 30 minutes of aeration are not suitable for direct disposal in the environment due to biohazards resulting from high toxicity of washings. On the other hand extension of the aeration process (160 minutes) contributed to significant improvement of washings quality and removal of toxic properties in relation to the indicator species used in the research. Chemical dechlorination ended with varying results. Microtox® bioluminescence assay resulted in bacteria bioluminescence with simultaneous observation of death of individual larvae. Despite high increase of biomass in Lemna minor test, some gradual decolouration of shoots as the result of washings used. In further solutions for recycling must be sought which will provide reduced water consumption and sewage.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 185-193
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena cieplno-wilgotnościowa stropodachu szczelinowego nad basenem na przykładzie rozwiązania zrealizowanego w praktyce
Evaluation of the thermal and damp properties of a slotted flat roof over a swimming pool, based on a practical example
Autorzy:
Byrdy, A.
Kisilewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/163551.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
basen
stropodach szczelinowy
właściwości cieplno-wilgotnościowe
przykład
swimming pool
slotted flat roof
thermal and moisture control properties
example
Opis:
Hale krytych basenów są obiektami, w których panuje wysoka temperatura i wilgotność względna powietrza wewnętrznego. Takie warunki stawiają wysokie wymagania przy projektowaniu przegród zewnętrznych tego rodzaju obiektów, ze szczególnym uwzględnieniem stropodachów. W artykule przeanalizowano błędy projektowe w przykładowym zrealizowanym stropodachu, który wykazał problemy eksploatacyjne już w pierwszych miesiącach funkcjonowania obiektu.
Indoor swimming pool buildings are subject to high temperatures and relative humidity of the air in their interior. These conditions entail stringent requirements for the design of the external partitions of such buildings, particularly their flat roofs. This article contains an analysis of design errors based on the example of a roof which suffered operational problems only months after the facility was opened.
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 2, 2; 47-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan zachowania i sposoby renowacji żelbetowych niecek basenowych
The condition and manners of the renovation of reinforced concrete swimming-pools
Autorzy:
Pająk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/162027.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
pływalnia
konstrukcja żelbetowa
stan techniczny
korozja zbrojenia
renowacja
swimming pool
reinforced concrete structures
technical state
reinforcement corrosion
renovation method
Opis:
Żelbetowe niecki basenowe otwartych i krytych pływalni narażone są na oddziaływania agresywnych środowisk atmosferycznych, gruntowych oraz wodnych powodujących korozję betonu i zbrojenia. W artykule na kilku przykładach żelbetowych niecek, zrealizowanych w latach 70. XX w., przedstawiono stan zachowania konstrukcji. Opisano najczęściej występujące uszkodzenia i ich wpływ na nośność i bezpieczeństwo konstrukcji. Przedstawiono stosowane sposoby renowacji i wzmocnień uszkodzonych niecek basenowych.
Reinforced concrete structures of swimming-pools are exposed to influences of aggressive atmospheric environment, soil environment and water environment, causing the corrosion of concrete and reinforcement. A few examples of reinforced concrete swimming-pools, build in 70 years the 20th century, the condition of the structure was presented. Most often appearing damage and their influence on the carrying capacity and the safety of the structure were described. Applied manners of the renovation and construction strengthening were presented.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 6, 6; 63-66
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
UV filters as disinfection by-products precursors in swimming pool water
Filtry UV jako prekursory tworzenia ubocznych produktów chlorowania wody basenowej
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Nowak-Bator, M.
Powiązania:
https://bibliotekanauki.pl/articles/127505.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
disinfection by-products
personal care products
UV filters
swimming pool water
uboczne produkty dezynfekcji
kosmetyki
filtry UV
woda basenowa
Opis:
The disinfection by-products formation precursors, which are brought into swimming water with swimmers, are not only the human body fluids released during the workout, but also hair, epidermis and residues of personal care products. The cosmetics contain the whole range of substances, however UV filters have the special importance in a case of swimming water. The article presents the results of experiments on the disinfection by-products formation potential of model solutions of UV filters: ethylhexyl methoxycinnamate (EHMC); butyl methoxydibenzoylmethane (BM-DBM); 4-methylbenzylidene camphor (4-MBC); octocrylene (OC); benzophenone-3 (BP3); ethylhexyl salicylate (EHS), octyl dimethyl-para-amino-benzoic acid (OD-PABA). These substances belong to different groups of cosmetics commonly used to protect skin against solar radiation. In the presented research the following by-products were analyzed: trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane, tribromomethane), haloacetic acids (monochloroacetic acid, dichloroacetic acid, bromochloroacetic acid, dibromoacetic acid, trichloroacetic acid), haloacetonitriles (bromochloroacetonitrile, dibromoacetonitrile, dichloroacetonitrile, trichloroacetonitrile), haloketones (1,1-dichloro-2-propanone, 1,1,1-trichloro-2-propanone), chloropicrin and chloral hydrate. For the experiments, the test of by-products formation potential in swimming water was applied, with 24 h time of swimming water samples incubation. The results were used to define which UV filters have the highest potential to form halogenated organic by-products of water chlorination.
Wprowadzane z osobami kąpiącymi się do wody basenowej prekursory tworzenia produktów ubocznych dezynfekcji to nie tylko wydzieliny ciała uwalniane podczas wysiłku, ale także włosy, naskórek oraz zanieczyszczenia, znajdujące się na powierzchni skóry, pochodzące ze środków do pielęgnacji ciała. Składniki kosmetyków to cała gama związków, jednak filtry UV w przypadku wody basenowej mają szczególne znaczenie. W artykule przedstawiono wyniki badań nad potencjałem tworzenia się szeregu organicznych produktów ubocznych chlorowania modelowych roztworów zawierających filtry UV: 4-metoksycynamonian 2-etyloheksylu (EHMC); 1-(4-tert-butylofenylo)-3-(4-metoksyfenylo)propano-1,3-don (BM-DBM); 3-(4-metylobenzylideno)-d-1 kamfora (4-MBC); ester 2-etyloheksylowy kwasu 2-cyjano-3,3-difenyloakrylowego (OC); 2-hydroksy-4metoksybenzofenon (BP3); ester 2-etyloheksylowy kwasu salicylowego (EHS), ester 2-etyloheksylowy kwasu 4-dimetyloaminobenzoesowego (OD-PABA). Związki te należą do różnych grup związków powszechnie używanych do ochrony skóry przed promieniowaniem słonecznym. W badaniach przeanalizowano potencjał tworzenia się następujących produktów ubocznych: trihalometanów (trichlorometan, bromodichlorometan, dibromochlorometan, tribromometan), kwasów halogenooctowych (kwas monochlorooctowy, kwas dichlorooctowy, kwas trichlorooctowy, kwas bromochlorooctowy i kwas dibromooctowy), haloacetonitryli (trichloroacetonitryl, dichloroacetonitryl, bromochloroacetonitryl, dibromoacetonitryl), haloketonów (1,1-dichloroproponon, 1,1,1-trichloropropanon) oraz wodzianu chloralu i chloropikryny. Badania prowadzono z wykorzystaniem testu na potencjał tworzenia się produktów ubocznych w wodzie basenowej, stosując 24 h czas inkubacji próbek wody basenowej. Analiza otrzymanych wyników pozwoliła ocenić, które związki z grupy filtrów UV mają najwyższe powinowactwo do tworzenia się halogenowych organicznych produktów chlorowania wody.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 577-584
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Swimming and bathing in Czechoslovakia until 1938
Pływanie i kąpiele w Czechosłowacji do roku 1938
Autorzy:
Tomsova, P.
Powiązania:
https://bibliotekanauki.pl/articles/529292.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
swimming
bathing
Czechoslovakia history
19-20th century
swimming pool
Czechoslovak Amateur Swimming Association
swimmer
pływanie
kąpielisko
historia Czechosłowacji
basen pływacki
XIX i XX wiek
czechosłowacki związek pływacki amatorów
Opis:
Pływanie i kąpiele w Czechach i Słowacji zaczęły sie formować u progu XIX wieku. Począt-kowo korzystano z odpowiednich warunków naturalnych, stąd pierwsze kąpieliska budowano przede wszystkim w korytach rzek. Pierwsze zawody pływackie zorganizowano w 1845 roku na Wełtawie, a w 1890 roku założono w AC Prague Sports Club sekcję pływacką, która obejmowała również pływanie wyczynowe. W 1914 roku założono Czeski Związek Pływacki, a w 1919 zmie-niono jego nazwę na Czechosłowackie Towarzystwo Amatorów Pływania. Liczba basenów pły-wackich była w tamtych czasach niewielka, warunki stworzone czechosłowackim pływakom nie by-ły idealne, a to sprawiło, że ich wyniki w międzynarodowych zawodach pływackich nie były imponujące.
Swimming and bathing in Czechoslovakia started to take shape at the beginning of the 19th century. At first, suitable locations in nature were used, with the first swimming baths built later on, primarily on rivers. The first competitive swimming races were held in 1845 on the Vltava River and in 1890, the AC Prague Sports Club founded a swimming department which also in-cluded competitive swimming races. In 1914, the Czech Union of Swimming was founded and in 1919 it was renamed as the Czechoslovak Amateur Swimming Association. The number of swimming pools at this time was very low, the conditions of Czechoslovak swimmers were not ideal, and their results at international swimming competitions suffered as a result.
Źródło:
Sport i Turystyka. Środkowoeuropejskie Czasopismo Naukowe; 2018, 1, 1; 43-53
2545-3211
Pojawia się w:
Sport i Turystyka. Środkowoeuropejskie Czasopismo Naukowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości stosowania promieniowania nadfioletowego w uzdatnianiu wody basenowej – studium przypadku
Assessment of applicability of UV irradiation in swimming pool water treatment – a case study
Autorzy:
Włodyka-Bergier, A.
Bergier, T.
Zając, W.
Powiązania:
https://bibliotekanauki.pl/articles/237754.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
swimming pool water
water treatment
UV irradiation
disinfection by-products
operating costs
woda basenowa
uzdatnianie wody
promieniowanie UV
produkty uboczne dezynfekcji
koszty eksploatacji
Opis:
Influence of UV-chlorination sequence application on swimming pool water quality was investigated. In addition, an analysis of operating costs of such system was conducted. The study was based on a real facility, i.e. the swimming pool of AGH University of Science and Technology in Krakow. In the facility, water disinfection with calcium hypochlorite was carried out, assisted by UV irradiation. Switching the UV lamps temporarily off allowed for comparative studies on the quality of pool water disinfected by pure chlorination and by the UV and chlorination sequence. For these two variants of the swimming pool water disinfection several physico-chemical and microbiological parameters were analyzed, including the disinfection by-products. Cost analysis included the consumption of chemical agents and the UV lamp operation. It was established that the UV technology did not contribute to the expected improvement in the pool water quality in terms of the combined chlorine removal, however it did cause an increase in the concentration of selected organic chlorination by-products. Moreover, application of the UV lamp to the pool water treatment system increased the chlorine demand and, consequently, the consumption of calcium hypochlorite. Combined with the need to exchange lamp fi laments, it raised the operating costs of the pool water treatment technology.
Badano wpływ zastosowania technologii UV w połączeniu z chlorowaniem na jakość wody basenowej, a także przeprowadzono analizę kosztów eksploatacyjnych takiego systemu. Badania przeprowadzono na rzeczywistym obiekcie, jakim jest basen sportowy Akademii Górniczo-Hutniczej w Krakowie. W obiekcie tym dezynfekcja wody jest prowadzona z wykorzystaniem podchlorynu wapnia, a proces ten jest wspomagany naświetlaniem wody promieniami nadfioletowymi (UV). Wyłączenie lamp UV na określony czas pozwoliło na przeprowadzenie badań porównawczych jakości wody basenowej dezynfekowanej tylko chlorem oraz z zastosowaniem układu UV/Cl2. Przeanalizowano szereg wskaźników mikrobiologicznych oraz fizyczno-chemicznych, w tym produktów ubocznych chlorowania, w obu wariantach dezynfekcji wody basenowej. W analizie kosztów uwzględniono zużycie chemikaliów oraz koszty promiennika UV. Stwierdzono, że technologia UV nie spowodowała oczekiwanej poprawy jakości wody basenowej pod względem usuwania chloru związanego, natomiast wpłynęła na zwiększenie ilości niektórych organicznych ubocznych produktów chlorowania. Włączenie lampy UV w system uzdatniania wody basenowej spowodowało również wzrost zapotrzebowania wody na chlor, a w rezultacie większe zużycie podchlorynu wapnia, co w połączeniu z koniecznością wymiany żarników lampy zwiększyło koszty eksploatacyjne technologii uzdatniania wody basenowej.
Źródło:
Ochrona Środowiska; 2017, 39, 1; 53-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przydatnośc bakterii grupy Coli jako wskaźnika zanieczyszczenia wody w pływalniach
Prigodnost bakterii gruppy Coli kak pokazatelja zagrjagrjaznenija vody v basseinah dlja v basseinah dlja plavanija
The applicability of the Coli group bacteria as the sanitary indicator of the degree of contamination of water in swimming pools
Autorzy:
Haman, S.
Powiązania:
https://bibliotekanauki.pl/articles/872681.pdf
Data publikacji:
1970
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
zanieczyszczenie wod
plywalnie
Escherichia coli
bakterie
badania sanitarne
badania bakteriologiczne
badania naukowe
water pollutant
swimming pool
bacteria
sanitary research
bacteriological examination
scientific research
Źródło:
Roczniki Państwowego Zakładu Higieny; 1970, 21, 2
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności procesu koagulacji w oczyszczaniu popłuczyn z układu cyrkulacji wody basenowej
Evaluation of coagulation process effectiveness in purification of filter washings from swimming pool circulation system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/236975.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda basenowa
popłuczyny z filtrów
oczyszczanie
fitotoksyczność
koagulacja
sole glinu
sole żelaza
rzęsa wodna
rzeżucha
swimming pool water
backwash water
purification
phytotoxicity
coagulation
aluminium salts
iron salts
Lemna minor
Lepidium sativum
Opis:
Oceniono możliwości zastosowania procesu koagulacji do oczyszczania popłuczyn z płukania złóż filtracyjnych pracujących w układzie cyrkulacji wody basenowej. Usunięcie części zanieczyszczeń z popłuczyn pozwoliłoby na ich odprowadzanie bezpośrednio do środowiska (np. do nawadniania zieleni) oraz na ograniczenie ilości ścieków odprowadzanych do kanalizacji. W badaniach laboratoryjnych zastosowano cztery różne koagulanty – glinowe (PAX) i żelazowe (PIX) – w zakresie dawek od 1,5 mg/dm3 do 6,0 mg/dm3. Analizie zmian wartości wybranych wskaźników fizyczno-chemicznych (barwa, zawiesiny ogólne, mętność, chlor ogólny, fosfor ogólny, absorbancja w nadfiolecie, ChZT oraz wskaźnik fenolowy) towarzyszyła także analiza fitotoksyczności składników popłuczyn (cieczy nadosadowej i osadów) w stosunku do wybranych roślin wskaźnikowych – rzęsa (Lemna minor) i rzeżucha (Lepidium sativum). Przeprowadzone testy naczyniowe procesu koagulacji pozwoliły na uzyskanie jakości popłuczyn pozwalającej na wprowadzenie ich bezpośrednio do środowiska. Niezależnie od zastosowanego rodzaju koagulantu, poprawa jakości fizyczno-chemicznej popłuczyn została osiągnięta już przy dawkach w zakresie 1,5÷3,0 mg/dm3, przy czym najskuteczniejszy okazał się PAX 25, będący mieszaniną polichlorku glinu i chlorku żelaza(II). Dodatkowo nie odnotowano efektu fitotoksycznego zarówno cieczy nadosadowej, jak i osadów pokoagulacyjnych. Tak oczyszczone popłuczyny mogą być wykorzystane na przykład do nawadniania zieleni na terenach obiektów basenowych.
Applicability of coagulation technique in purification of filter washings from the swimming pool circulation system was evaluated. Removal of some of the contaminants from washings would allow for their discharge directly into the environment (e.g., for irrigation of greenery) and limiting the amount of sewage entering the sewer. In the laboratory studies, four different coagulants were used – aluminum (PAX) and ferric (PIX) – in doses ranging 1.5–6.0 mg/dm3. In addition, the analysis of fluctuations of the values of selected physicochemical parameters (color, general suspensions, turbidity, total chlorine, total phosphorus, ultraviolet absorbance, COD and phenol index) was accompanied by the analysis of washing components (supernatant liquid and sediments) phytotoxicity against the selected indicator plants – eyelash (Lemna minor) and cress (Lepidium sativum). The jar tests conducted throughout the coagulation process resulted in washings of quality adequate to be introduced directly into the environment. Regardless of the type of coagulant used, the improvement of physicochemical parameters of washings was achieved already at doses in the range of 1.5–3.0 mg/dm3, with PAX 25, polyaluminum chloride and iron chloride(II) mixture, being the most effective. In addition, no phytotoxic effect of both the supernatant and post-coagulation sediments was noted. Such purified washings could be employed for example in watering greenery at swimming pool areas.
Źródło:
Ochrona Środowiska; 2018, 40, 1; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania jakości popłuczyn ze stacji filtrów w obiekcie basenowym w aspekcie możliwości odprowadzania ich do wód lub do ziemi – studium przypadku
Studies of backwash water quality from a swimming pool filter plant in terms of their discharge to surface water bodies or into the ground – a case study
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/237337.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
swimming pool
backwashing
filter washings
backwash water
sedimentation
coagulation
discharge into a river
draining into the ground
basen
płukanie złóż filtracyjnych
wody popłuczne
popłuczyny
sedymentacja
koagulacja
odprowadzanie do rzeki
rozsączanie w gruncie
Opis:
Results of research on physico-chemical and bacteriological quality of effluents from backwashing of filter beds were presented for water treatment system of a selected swimming pool (waterpark). The aim of these studies was to evaluate potential to discharge the backwash water from rapid filter beds to a river or to drain them into the ground. Based on the physico-chemical and microbiological analysis of backwash water samples, degree of their contamination was determined with regard to the current quality requirements for wastewater discharged into surface water or soil as well as the requirements under the Water Law Act that defined water quality to be discharged from the analyzed pool. It was demonstrated that direct routing of the eluate from backwashing into the river or soil was impossible due to a high amount of total suspended solids and chlorine content. The concurrent efficacy testing of sedimentation and alum coagulation of backwash water performed under laboratory conditions demonstrated that the obtained supernatant water complied with the requirements and might be discharged into the river or drained into the ground.
Przedstawiono wyniki badań jakości fizyczno-chemicznej i bakteriologicznej popłuczyn powstających w wyniku płukania złóż filtracyjnych w układzie oczyszczania wody w wybranym obiekcie basenowym (park wodny). Celem badań było określenie możliwości odprowadzania popłuczyn z filtrów pospiesznych do rzeki lub ich rozsączania w gruncie. Na podstawie wyników analiz fizyczno-chemicznych i mikrobiologicznych próbek popłuczyn określono stopień ich zanieczyszczenia w odniesieniu do wymagań dotyczących jakości ścieków odprowadzanych do wód lub do ziemi obowiązujących w Polsce oraz wymagań zawartych w pozwoleniu wodnoprawnym, które określa wymaganą jakość wód odprowadzanych z analizowanego obiektu basenowego. Wykazano, że bezpośrednie odprowadzanie popłuczyn z płukania filtrów do rzeki lub ziemi jest niemożliwe, ze względu na dużą ilość zawiesin ogólnych oraz zawartość chloru w popłuczynach. Jednocześnie przeprowadzone w warunkach laboratoryjnych badania skuteczności procesów sedymentacji i koagulacji objętościowej popłuczyn koagulantem glinowym wykazały, że uzyskane w ten sposób wody nadosadowe spełniają warunki odprowadzania ich do rzeki lub rozsączania w gruncie.
Źródło:
Ochrona Środowiska; 2017, 39, 2; 45-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geotechniczne uwarunkowania posadowienia obiektów budowlanych
Geotechnical conditions for foundation of building structures
Autorzy:
Sendkowski, J.
Tkaczyk, A.
Tkaczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/162959.pdf
Data publikacji:
2016
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
inwestycja budowlana
strategia projektowa
fundament
warunki geotechniczne
badanie podłoża
hala sportowa
basen
wieża telefonii komórkowej
budynek biurowy
building investment
design strategy
foundation
geotechnical conditions
subsoil testing
sport hall
swimming pool
cellular phone tower
office building
Opis:
W pracy na wybranych przykładach omówiono geotechniczne uwarunkowania posadowienia obiektów budowlanych w kontekście wymagań PN-EN-1997–1. Pokazano istotny udział geotechnika w trakcie całego procesu budowlanego. Zamieszczone przykłady mogą stanowić podstawę do dalszej dyskusji nad uwarunkowaniami posadowienia obiektów budowlanych współpracujących z podłożem, niezależnie od warunków gruntowych i kategorii geotechnicznej obiektów.
Within the present work, geotechnical conditions for foundation of building structures is discussed, within the framework of the requirements concerning the PN-EN-1997–1 norm. The important contribution the geotechnician may make to the building erection process has also been highlighted. The presented examples may form a base for further discussion of conditioning the foundation of building structures which act in cooperation with the ground, regardless of the ground conditions and geotechnical category for the structure.
Źródło:
Przegląd Budowlany; 2016, R. 87, nr 11, 11; 18-24
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-40 z 40

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies