Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "spękanie" wg kryterium: Temat


Tytuł:
Tectonic setting of the poszukiwaczy skarbów cave and the GrobyCave (Kraków gorge, western Tatra Mts., Poland)
Autorzy:
Szczygieł, J.
Gaidzik, K.
Powiązania:
https://bibliotekanauki.pl/articles/100852.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Nauk o Ziemi
Tematy:
jaskinia
tektonika
Tatry
osad
spękanie
cave
tectonics
Tatra Mts.
cover
joint
Opis:
The study area is located in the Tatra Mts., the part of Western Carpathians. In the Poszukiwaczy Skarbów Cave and the Groby Cave a tectonics structures has been documented. The structural analysis were made. In both caves the following joints set have been identified from 4 maximum of statistic analysis: 157/85 (max.I), 143/63 (max.II), 58/63 (max.III), 304/70 (max.IV). Nevertheless joint set participation of individual caves development have been diverse. In the development of the Poszukiwaczy Skarbów Cave, the most important joint set were latitudinal which is conjugate with fractures of III. maximum. This crossing of joints sets contribute to development of the main chamber. Maximum III has been very important in the evolution of passages of the Groby Cave. Conjugated with joint of max. IV determined the conduit direction. Entrance chamber formed in this place because the overthrust disintegrated a rocks there.
Jaskinia Poszukiwaczy Skarbów i Jaskinia Groby zlokalizowane są w Tatrach, w dolnej, zachodniej części Wąwozu Kraków. W jaskiniach wykonano pomiary orientacji struktur tektonicznych. Następnie wykonano analizę strukturalną, która pozwoliła wyznaczyć 4 główne zespoły spękań: 157/85 (max.I), 143/63 (max.II), 58/63 (max.III), 304/70 (max.IV). Udział poszczególnych zespołów spękań w obu jaskiniach był zróżnicowany. W Jaskini Poszukiwacz Skarbów najistotniejszy w rozwoju jaskini jest zespół spękań równoleżnikowych. Jego sprzężenie ze spękaniami III. maksimum uwarunkowało rozwój głównej komory. Spękania maksimum III są również istotne w rozwoju Jaskini Groby. Sprzężone z zespołem spękań max. IV determinowały kierunek korytarzy jaskini. Komora wstępna w Jaskini Groby założona jest na nasunięciu, które przyczyniło się do dezintegracji skał i ułatwiło rozwój sali.
Źródło:
Contemporary Trends in Geoscience; 2012, 1, 1; 93-98
2299-8179
Pojawia się w:
Contemporary Trends in Geoscience
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydraulic fracturing in systems of geothermal energy utilization (EGS, HDR)
Autorzy:
Śliwa, T.
Szura, M.
Gonet, A.
Sapińska-Śliwa, A.
Powiązania:
https://bibliotekanauki.pl/articles/299111.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
geoenergetics
boreholes
hydraulic fracturing
Enhanced Geothermal System (EGS)
HDR
geoenergetyka
spękanie hydrauliczne
otwory wiertnicze
Opis:
This work reviews possibility of using the heat from impermeable hot dry rock formations. Significant development in hydraulic fracturing technique in a last few years have a result in making accessible sources of energy from impermeable rocks, including hot dry rocks, which wasn't possible before. This paper presents the idea of utilization the EGS system which is based on forced and closed water circulation in a natural and permeable geological reservoir or in a reservoir, where the fractured zone was created artificially by for example hydraulic fracturing treatment. The article shows also an examples of recent EGS/HDR systems around the world.
Źródło:
AGH Drilling, Oil, Gas; 2012, 29, 3; 433-437
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awarie i diagnostyka asfaltowych nawierzchni drogowych
Damage and diagnosis of road surfaces
Autorzy:
Iwański, M.
Powiązania:
https://bibliotekanauki.pl/articles/128784.pdf
Data publikacji:
2017
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
uszkodzenie mrozowe
spękanie odbite
diagnostyka
nawierzchnia drogowa
warstwa asfaltowa
frost damage
reflected crack
diagnosis
road surface
asphalt layer
Opis:
Artykuł omawia dwie grupy uszkodzeń, jakie mogą powstawać na drogach. Do najczęściej występujących uszkodzeń w głębi konstrukcji nawierzchni zalicza się odbite spękania poprzeczne będące z reguły wynikiem pozostawienia dolnych warstw konstrukcyjnych, wykonanych z materiałów na bazie cementu. Natomiast uszkodzenia nowych nawierzchni asfaltowych to powstawanie trwałych deformacji plastycznych (kolein), utrata wodo- i mrozoodporności oraz szorstkości. Dzięki nowoczesnej aparaturze kontrolno-pomiarowej możliwa jest szczegółowa analiza właściwości materiałowych, parametrów powierzchniowych, a tym samym prognozowanie trwałości nawierzchni asfaltowych.
The article describes two groups of damage that may affect roads. The most prevalent damage inside the construction of the surface are reflected transverse cracks, being usually a result of leaving the bottom cement-based structural layers. However damage appearing on the surface of new asphalt surfaces is the formation of permanent deformations (wheelruts), loss of water and frost resistance, and loss of roughness. Thanks to the modern control and measurement apparatus, it is possible to profoundly analyse the material properties, surface parameters and consequently to forecast the durability of asphalt surfaces.
Źródło:
Builder; 2017, 21, 5; 112-115
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Material test on strain fracture and crack opening displacement based on digital image correlation method
Badania materiału pod kątem złamania z oderwania i przemieszczenia otworu szczeliny w oparciu o metodę cyfrowej korelacji obrazów
Autorzy:
Bian, J.
Ge, Z.
Powiązania:
https://bibliotekanauki.pl/articles/231289.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metoda cyfrowej korelacji obrazów
rysa
spękanie
przemieszczenie
spawanie
digital image correlation method
crack
fracture
displacement
welding
Opis:
As a machining technology, welding can cause serious accidents by overloading or operation mistakes. Through analyzing the causes of various welding accidents, we found that the major cause for damage imposed after welding parts are loaded is the fracture of materials. Therefore, studying the influence of welding residual stress on the fracture property of materials is of great significance. This paper applied the digital image correlation technique to study the fracture property of welding parts under the influence of welding residual stress. In addition, standard parts and welding parts were selected to carry out a contrast experiment. Room temperature tensile tests were performed on both standard parts and test pieces after residual stress measurement. Using displacement field and strain field data obtained through VIC-2D software, the stress intensity factor around the crack tip of each specimen under the conditions of small load was calculated and corresponding analysis was carried out.
Spawanie, jako technologia procesu obróbki skrawaniem i produkcji, łączy materiały poprzez podgrzewanie materiałów zanim wysoka temperatura je stopi, a następnie chłodzi. Jego zaletą jest szeroki zakres zastosowań, łatwość obsługi, niskie koszty, itd. Jest ono stosowane w różnych dziedzinach, takich jak budowa statków, samolotów i innych dużych urządzeń produkcyjnych, produkcji miniaturowej elektroniki i różnego rodzaju płytek drukowanych, itp., co uczyniło nasze życie ogromnie wygodnym. Jednak spawanie może spowodować wiele wad, jeżeli zaistnieje jakikolwiek niewłaściwy proces technologiczny, który może obniżyć intensywność spawania części oraz wpłynąć na ich działanie. Ponadto przeciążenie lub błędy w działaniu podczas użytkowania mogą spowodować poważne wypadki. Poprzez analizę przyczyn różnych wypadków przy spawaniu, stwierdziliśmy, że głównym powodem inaktywacji uszkodzeń po spawaniu obciążanej części było złamanie materiałów. Mikroskopijne pęknięcie wewnątrz materiałów to początek powstawania obu wad w obszarze spawanego materiału oraz zmęczenia materiału spowodowanego przez zmienne obciążenie. W wyniku połączenia działania spawalniczych naprężeń własnych i zastosowanego obciążenia, pęknięcie stale się powiększa zanim nie stanie się mikroskopijnym pęknięciem. Następnie wciąż się rozszerza i w końcu prowadzi do złamania materiałów. Występowanie naprężeń własnych w spawanych elementach poważnie wpłynie na wydajność operacyjną konstrukcji. W związku z tym badanie wpływu spawalniczych naprężeń własnych na właściwości złamania materiałów ma ogromne znaczenie.
Źródło:
Archives of Civil Engineering; 2016, 62, 3; 3-22
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenia i naprawa stropów żelbetowych w budynku wielorodzinnym
Damage and repair of reinforced concrete floors in a multi-family building
Autorzy:
Klimek, A
Matkowski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/160319.pdf
Data publikacji:
2016
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek mieszkalny
uszkodzenie
spękanie
analiza przyczyn
sposób naprawy
residential building
damage
cracking
causes analysis
repair method
Opis:
W artykule przedstawiono skutki wprowadzonych na budowie nierozważnych zmian w konstrukcji budynku, analizę przyczyn uszkodzeń oraz sposób naprawy stropów gęstożebrowych, które wskutek przeciążenia doznały znacznych ugięć, wywołując spękania stojących na nich masywnych ścian działowych. Zaprojektowano naprawę w dwu fazach, w fazie I zapewniając odpowiednią nośność stropów, a w fazie II zabezpieczając ściany przed dalszymi zarysowaniami.
The article presents the consequences of introducing imprudent changes in the construction of a building at the building site, an analysis of damage causes as well as the method of repair of the suspended beam and block floors, which suffered significant bending due to overload. The bending caused cracks of massive partition walls which stood on the floors. The present paper presents a repair scheme with two phases, which in phase I consists in providing adequate load-bearing capacity of floors, whereas in phase II – in protecting the walls against further scratching.
Źródło:
Przegląd Budowlany; 2016, R. 87, nr 3, 3; 18-20
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rzeźba granitowego skalnego miasta Starościńskich Skał w Rudawach Janowickich (Sudety Zachodnie)
Morphology of the granite rock city of Starościńskie Skały in the Rudawy Janowickie (Western Sudetes)
Autorzy:
Michniewicz, A.
Jancewicz, K.
Różycka, M.
Migoń, P.
Powiązania:
https://bibliotekanauki.pl/articles/294402.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Geomorfologów Polskich
Tematy:
formy rzeźby granitowej
skalne miasto
wietrzenie granitu
spękanie
Sudety
granite landforms
rock city
granite weathering
jointing pattern
Sudetes
Opis:
Praca zawiera opis grupy Starościńskich Skał w północnej części Rudaw Janowickich, która stanowi jedyny w polskich Sudetach przykład granitowego „skalnego miasta”. Starościńskie Skały to złożona forma ostańcowa, składająca się z szeregu skałek usytuowanych na granitowym cokole o cechach wzgórza wyspowego. Wyniki kartowania terenowego zostały przedstawione na szczegółowej mapie geomorfologicznej, zawierającej 30 wydzieleń. Głównym czynnikiem odpowiedzialnym za rzeźbę skałek jest zróżnicowany system spękań (koncentryczny i prostokątny), do którego nawiązuje dwudzielność kompleksu skalnego. Cechą charakterystyczną tej grupy skalnej jest występowanie bogatej mikrorzeźby, która świadczy o jej stabilności i długim rozwoju powierzchniowym. Niektóre elementy mikrorzeźby – nisze kloszowe – dowodzą jednak tego, że w pierwszym etapie rozwoju skałki były kształtowane podpowierzchniowo, przy istotnym udziale wietrzenia chemicznego.
The paper presents a description of the Starościńskie Skały tor group located in the northern part of the Rudawy Janowickie which is the only example of a granite rock city in the Polish Sudetes. Starościńskie Skały is a specific complex landform composed of various tors situated on a dome-like pedestal. The results of detailed field landform mapping are presented on geomorphological map, which contains 30 elements. The major factor influencing morphology of the Starościńskie Skały is a complex system of joints (sheeting and orthogonal joints) which control the shape of the residual and are responsible for morphological duality of the rock city. A characteristic feature of this tor group is the presence of varied microrelief, which indicates surface stability and protracted development at the surface. However, certain components of microrelief – flared slopes – are an evidence of subsurface chemical weathering of Starościńskie Skały tor group in the first stage of their development.
Źródło:
Landform Analysis; 2016, 31; 17-33
1429-799X
Pojawia się w:
Landform Analysis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Awarie w budynkach spowodowane błędnymi rozwiązaniami konstrukcyjnymi
Failures in building caused by incorrect construction solutions
Autorzy:
Wesołowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/161170.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
awaria budynku
spękanie
przyczyna awarii
rozwiązanie konstrukcyjne
błąd projektowania
building failure
cracking
failure cause
structural solution
design error
Opis:
W pracy przedstawiono stany awaryjne dwóch budynków: mieszkalno-usługowego oraz mieszkalnego, w których doszło do niekontrolowanych zarysowań ścian wewnętrznych, skutkujących utrudnieniami eksploatacyjnymi dla użytkowników mieszkań. Przeprowadzona analiza wykazała, że w obydwu przypadkach doszło do poważnych błędów na etapie projektowania obiektów, gdzie dość pobieżnie i bezrefleksyjnie projektanci podeszli do analizy stanu granicznego użytkowalności w aspekcie ugięć stropów.
This thesis presents the emergency situations of two buildings: residential & commercial, and residential, where uncontrolled scratches of internal walls occurred, resulting in operational difficulties for the users of apartments. The analysis showed, that in both cases, there were serious errors in the design of the objects, where the designers in a sketchy and unreflective way, approached the serviceability limit state analysis in the aspect of deflection of the ceiling.
Źródło:
Przegląd Budowlany; 2017, 88, 6; 46-50
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of higher modes vibrations on local cracks in node of lattice girders bridges
Wpływ wyższych postaci drgań na zaistnienie lokalnych spękań w węźle mostu kratowego
Autorzy:
Pradelok, S.
Powiązania:
https://bibliotekanauki.pl/articles/230804.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
most
węzeł
dźwigar kratowy
wibracje
spękanie
model szczegółowy
analiza dynamiczna
zmęczenie
bridge
node
lattice girder
vibration
cracking
detailed model
dynamic analysis
fatigue analysis
Opis:
Several previous investigations on failure of a certain type lattice girders railway bridge (on so called BJD line) have not convincingly explained reasons nor have they described potential hazards. This paper attempts to provide an answer, employing static, dynamic, and fatigue analysis of the structure, focusing on previously not analyzed vibrations of elements constituting a lattice node. Detailed models of two types of such nodes – damaged and non-damaged were compared, inside carefully defined limits of applicability.
W kolejowym moście kratowym zdarzyły się trudne do wytłumaczenia awarie. Mimo licznych wcześniejszych ekspertyz i badań naukowych nie udało się w sposób jednoznaczny ustalić przyczyn tych awarii. Ustrój nośny, który uległ awarii, jest częścią wiekszego obiektu mostowego złożonego z sześciu niezależnych, swobodnie podpartych stalowych przeseł. Cztery z nich to przesła blachownicowe, a dwa pozostałe to bliźniacze przęsła kratowe. W blachownicowych przęsłach nie stwierdzono żadnych uszkodzeń. Natomiast w jednym z przęseł kratowych zauważono pęknięcia w dolnym pasie kratownicy. Pojawiły się one w wezłach położonych w okolicy przerwy w betonowym korycie pomostu. W drugim, bliźniaczym przęśle kratowym, położonym w tym samym torze, nie stwierdzono żadnych uszkodzeń pomimo wielokrotnych i dokładnych oględzin. Wykorzystano te szczególne okoliczności sprzyjające przeprowadzeniu badań porównawczych. W celu wyjaśnienia przyczyn pękania zbudowano szczegółowe modele obliczeniowe węzłów kratowego ustroju nośnego mostu kolejowego. Przedmiotem analiz były dwa węzły kratownic. Pierwszy to ten węzeł kratownicy, który uległ awarii, a drugi to jego odpowiednik w nieuszkodzonej kratownicy. W wyniku przeprowadzonych analiz obliczeniowych wykazano, że przyczyną uszkodzeń są lokalne wpływy statyczne i dynamiczne działające na tle rzeczywistego poziomu naprężeń. Współczesne metody numerycznej analizy mostów pozwalają na uzyskanie bardzo dokładnych wyników. Nie jest to jednak cała prawda, gdyż wyniki te są zależne od dokładności danych wprowadzonych do modelu obliczeniowego. Z tych względów należy otrzymane teoretycznie wyniki zweryfikować w badaniach terenowych. Badania terenowe dają dobrą podstawę do przeprowadzenia analizy jakościowej teoretycznych modeli obliczeniowych. Umożliwiają one weryfikację otrzymanych wyników z tych analiz. Przeprowadzona analiza obliczeniowa, potwierdzona badaniami terenowymi, pozwoliła jednoznacznie wyjaśnić przyczyny awarii. Zdołano obliczeniowo wykazać, dlaczego doszło do awarii w jednym przęśle kratowym, a w drugim, bliźniaczym, identycznie obciążonym przęśle kratowym takie uszkodzenia nie powstały.
Źródło:
Archives of Civil Engineering; 2012, 58, 2; 209-221
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of mechanical factors on the performance and aging process of oil pump jack
Wpływ czynników mechanicznych na wydajność i proces starzenia się kiwona
Autorzy:
Aliyev, Alesker M.
Aliyeva, Sevda Y.
Powiązania:
https://bibliotekanauki.pl/articles/31348293.pdf
Data publikacji:
2023
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
oil pump jack
vibration
wear
load
corrosion
swing frequency
mechanical factor
deformation
fracture
kiwon
drgania
zużycie
obciążenie
korozja
częstotliwość wychylenia
czynniki mechaniczne
odkształcenie
spękanie
Opis:
The paper discusses the influence of mechanical factors on the performance and aging process of rocking machines, specifically focusing on oilfield equipment such as the downhole rod pump jack. The authors emphasize the importance of analyzing the condition and aging process of oilfield equipment to ensure reliability, safety, and efficiency in oil production processes. The mechanical factors discussed in the paper include vibrations, loads, wear, and corrosion. Vibrations can be caused by improper balance, bearing failures, or other factors, and they have a negative impact on equipment performance and can lead to breakdowns. High mechanical loads associated with raising and lowering sucker rods can cause wear and damage to the pump jack. Operating in harsh environments with sand, abrasive particles, or chemicals can also cause wear on surfaces and equipment parts. Corrosion of metal components can occur due to moisture, chemical attack, or improper storage and maintenance, leading to deterioration and breakage of equipment. The consequences of these mechanical factors on the aging of an oil pump jack include accelerated aging, decreased performance, and an increased risk of accidents. Continuous exposure to vibration, stress, wear, and corrosion accelerates the aging process, resulting in deterioration and reduced equipment life. Damage and breakdowns caused by mechanical factors lead to decreased efficiency, negatively impacting oil production processes. Moreover, insufficient maintenance and failure to address mechanical influences increase the risk of accidents, downtime, and damage to other parts of the manufacturing process. To assess the health and aging status of an oil pump jack, various analysis and diagnostic methods are used, including visual inspection, strength testing, monitoring of parameters, and non-destructive testing. Visual inspection helps identify visible damage, wear, and defects. Strength testing evaluates the reliability of pump jack parts and identifies potential issues. Monitoring parameters like vibrations, temperature, and pressure allows for detecting deviations from normal operation and preventing breakdowns. Non-destructive testing methods such as ultrasonic testing, magnetic particle testing, and radiography help identify hidden defects and damage. The authors recommend several strategies to maintain the reliability and efficiency of an oil pump jack. These strategies include implementing a preventive maintenance program with regular inspection, testing, and parts replacement based on manufacturer’s recommendations and equipment condition analysis. Determining optimal service and part replacement intervals based on historical data, monitoring results, and manufacturer’s recommendations is crucial. Additionally, utilizing more durable materials, anti-corrosion coatings, improved designs, and technologies can increase equipment resistance to mechanical stress and improve performance. The paper also describes the device and components of a pump jack, such as the installation base, platform, balancer, electric motor, crank, connecting rod, and control station. It emphasizes the importance of considering various characteristics when selecting and evaluating the effectiveness of a pump jack, including working load, maximum plunger stroke, reducer dimensions, output torque, and swing frequency. The kinematics of the pump jack drive system are discussed, highlighting the need for reconfiguration to adapt to changing operating conditions and optimize oil production performance. Overall, the paper emphasizes the importance of analyzing mechanical factors, managing the aging process, and implementing maintenance strategies to ensure the reliable and efficient operation of oilfield equipment, specifically the pump jack used in oil production processes.
: W artykule omówiono wpływ czynników mechanicznych na wydajność i proces starzenia się kiwonów, koncentrując się na urządzeniach do eksploatacji złóż ropy naftowej. Autorzy podkreślają znaczenie analizy stanu i procesu starzenia się sprzętu naftowego dla zapewnienia niezawodności, bezpieczeństwa i wydajności procesów produkcji ropy naftowej. Czynniki mechaniczne omówione w artykule obejmują drgania, obciążenia, zużycie i korozję. Drgania mogą być wywołane przez nieodpowiednie zbalansowanie, usterki łożysk lub inne czynniki i mają negatywny wpływ na wydajność sprzętu oraz mogą prowadzić do awarii. Wysokie obciążenia mechaniczne powiązane z podnoszeniem i opuszczaniem żerdzi pompowych mogą powodować zużycie i uszkodzenie kiwona. Praca w trudnych środowiskach z piaskiem, cząstkami ścierającymi lub chemikaliami może także skutkować zużyciem powierzchni i części sprzętu. Korozja komponentów metalowych może wystąpić w związku z wilgocią, agresywnością chemiczną lub nieodpowiednim przechowywaniem i konserwacją i doprowadzić do degradacji i uszkodzeń sprzętu. Konsekwencje tych czynników mechanicznych względem starzenia się kiwona obejmują przyspieszone starzenie, zmniejszoną wydajność i zwiększone ryzyko wypadków. Stałe narażenie na drgania, naprężenie, zużycie i korozję przyspiesza proces starzenia, powodując degradację i zmniejszenie żywotności sprzętu. Uszkodzenia i awarie wywołane przez czynniki mechaniczne prowadzą do zmniejszenia wydajności, wpływając negatywnie na procesy produkcji ropy naftowej. Ponadto niewystarczająca konserwacja i brak uwzględnienia wpływów mechanicznych zwiększają ryzyko wypadków, przestoju i uszkodzenia innych elementów procesu produkcyjnego. Aby ocenić stan i status starzenia się kiwona, stosuje się różne analizy i metody diagnostyczne, w tym inspekcję wizualną, próby wytrzymałościowe, monitorowanie parametrów i próby nieniszczące. Inspekcja wizualna pomaga zidentyfikować widoczne uszkodzenia, zużycie i defekty. Próby wytrzymałościowe oceniają niezawodność części kiwona i identyfikują potencjalne problemy. Monitorowanie parametrów takich jak drgania, temperatura i ciśnienie pozwala wykryć odchylenia od normalnej pracy i zapobiec awariom. Metody prób nieniszczących, takie jak badania ultradźwiękowe, badania magnetyczno-proszkowe i radiografia, pomagają odnaleźć ukryte defekty i uszkodzenia. Autorzy rekomendują kilka strategii dla zachowania niezawodności i wydajności kiwona. Strategie te obejmują wdrożenie zapobiegawczego programu konserwacji z regularnymi przeglądami, testami i wymianą części na podstawie rekomendacji producenta i analizy stanu sprzętu. Kluczowe jest ustalenie optymalnych przedziałów serwisowania i wymiany części, opierając się na danych historycznych, wynikach monitoringu i rekomendacjach producenta. Dodatkowo stosowanie wytrzymalszych materiałów, powłok antykorozyjnych, ulepszonych konstrukcji i technologii może zwiększyć wytrzymałość sprzętu na naprężenia mechaniczne i poprawić wydajność. W artykule opisano także urządzenia i komponenty kiwona, takie jak podstawa instalacyjna, platforma, wahacz, silnik elektryczny, korba, żerdź łącząca i stanowisko sterowania. Podkreślono znaczenie uwzględnienia różnych cech podczas wyboru i oceny wydajności kiwona, w tym obciążenia roboczego, maksymalnego suwu tłoka, wymiarów reduktora, wyjściowego momentu obrotowego i częstotliwości ruchu wahadłowego. Omówiona została kinematyka systemu napędowego kiwona, z podkreśleniem potrzeby rekonfiguracji w celu przystosowania się do zmiennych warunków pracy i optymalizacji wydajności produkcji ropy naftowej. Ogólnie rzecz biorąc, w artykule podkreślono znaczenie analizy czynników mechanicznych, zarządzania procesem starzenia i wdrażania strategii konserwacji dla zapewnienia niezawodnej i wydajnej pracy sprzętu na złożach ropy naftowej, a konkretnie kiwona stosowanego w procesach produkcji ropy naftowej.
Źródło:
Nafta-Gaz; 2023, 79, 12; 776-785
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza przyczyn uszkodzenia stropu
Autorzy:
Jakubczyk, M.
Trochimiak, I.
Szydłowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/129255.pdf
Data publikacji:
2017
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
strop betonowy
płyta betonowa
skurcz betonu
spękanie betonu
rysa
analiza przyczyn
concrete floor
concrete slab
concrete shrinkage
concrete cracking
crack
causes analysis
Opis:
Analysis ol the cause of damage of a reinforced concrete floor above a garage of a multi-storey residential building. Undertaking an accurate assessment of the effects of concrete shrinkage and required minimum shrinkage reinforcement of complex reinforced concrete constructions emphasizes the fact of being an exceedingly difficult issue to consider. The analysis below broaches this matter basing on the example of a fragment of a building characterized by a rare construction system. Since the shrinkage aspects have not been taken into account, the applied reinforcement concerns only bending. Indeed, this fact, as well as the peculiarity of a shape of the building, affected the ceiling surface causing the emergence of a crack across its length and thus, plenty of leaks. The study of the above-mentioned case attempts to specify the quantity of required reinforcement by comparing results obtained from various methods adopted for this purpose.
Źródło:
Builder; 2017, 21, 8; 88-90
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka żelbetowej wieży antenowej o wysokości 60 m
Autorzy:
Lechman, Marek
Powiązania:
https://bibliotekanauki.pl/articles/128847.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
wieża antenowa
konstrukcja żelbetowa
segment rurowy
zarysowanie
spękanie
naprawa
stan techniczny
diagnostyka
antenna tower
reinforced concrete structure
tubular segment
crack
repair
technical condition
diagnostics
Opis:
Przedmiotem artykułu jest wieża antenowa o wysokości 60 m zaprojektowana w konstrukcji żelbetowej prefabrykowanej, składająca się z 5 segmentów rurowych wykonanych w technologii betonu wirowanego. Połączenia segmentów zaprojektowano w postaci specjalnych łączników, składających się z płyt stalowych skręcanych na śruby. W trakcie eksploatacji żelbetowy trzon wieży uległ zarysowaniom i spękaniom o różnym charakterze, co stanowiło bezpośredni asumpt do zbadania przyczyn ich powstania oraz określenia sposobu naprawy. Celowi temu służyły przeprowadzone badania diagnostyczne oraz obliczenia statyczno-wytrzymałościowe konstrukcji wieży, z uwzględnieniem oddziaływania wiatru według Eurokodu 1 oraz nieliniowości fizycznej betonu i stali zbrojeniowej. Na podstawie otrzymanych wyników określono stan techniczny wieży oraz podano sposoby wyeliminowania występujących uszkodzeń i nieprawidłowości.
The subject of this paper is a reinforced concrete (RC) antenna tower 60 m high consisted of 5 tubular segments made of spun concrete. The connections between segments were designed in the form of special joints consisted of steel plates fixed by screws. The reason for undertaking this issue was the occurrence of cracks on the external surface of the tower shaft. For this purpose the relevant investigations and static analysis of the tower structure have been performed in accordance with Eurocode 1 and by taking into account the physical nonlinearity of concrete and reinforcing steel. Based on the obtained results the diagnosis of tower structure and recommendations for its repair and protection were made.
Źródło:
Builder; 2020, 24, 4; 72-74
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarysowanie dwóch zbiorników na wodę
Cracking of the two water tanks
Autorzy:
Wesołowski, M.
Piotrkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/160576.pdf
Data publikacji:
2016
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
zbiornik cylindryczny
konstrukcja żelbetowa
spękanie
analiza statyczna
przyczyny uszkodzeń
błąd projektowania
błąd wykonawstwa
cylindrical tank
reinforced concrete structure
cracking
static analysis
fault causes
design fault
execution fault
Opis:
W pracy przedstawiono realizację dwóch zbiorników żelbetowych na wodę, usytuowanych przy brzegu Zatoki Gdańskiej. W zbiornikach tych podczas próby szczelności stwierdzono liczne przecieki w ścianach bocznych. Przeprowadzona szczegółowa analiza obliczeniowa wykazała, że w procesie inwestycyjnym popełniono szereg błędów na etapie projektowania oraz podczas wykonawstwa. Do podstawowych błędów projektowych należy zaliczyć pominięcie w nim analizy stanu granicznego użytkowalności w odniesieniu do sprawdzenia zarysowania betonu, gdyż w projekcie skupiono się jedynie na analizie stanu granicznego nośności dla uproszczonego schematu statycznego, nie odzwierciedlającego rzeczywistego zachowania się konstrukcji zbiorników. Do błędów wykonawczych należy zaliczyć brak szczegółowych danych odnośnie parametrów betonu oraz nieodpowiednią technologię wykonywania zbiorników, uniemożliwiającą właściwą kontrolę jakości betonu.
This paper presents realization of the two reinforced concrete water tanks, located on the shore of the Gulf of Gdansk. During the leak test, there were numerous leaks in the side walls in those tanks. A detailed computational analysis showed that in the investment process, a number of errors at the design stage and during the execution of the construction were committed. The fundamental mistake was omission of the serviceability limit state analysis in terms of check cracking in concrete because the project was focused only on ultimate limit state analysis for very simplified static diagram, which did not reflect the actual behavior of the structure of the tanks. To mistakes in execution should be included lack of a detailed informations about concrete parameters and inadequate technology of making tanks, preventing proper control of concrete quality.
Źródło:
Przegląd Budowlany; 2016, R. 87, nr 10, 10; 34-38
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of joints and micro-fractures on the limestone aggregate shape and quality
Wpływ ciosu i mikro-spękań na kształt ziaren i jakość kruszywa wapiennego
Autorzy:
Figarska-Warchoł, B.
Bromowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/216355.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
kruszywo łamane
kształt ziaren
spękanie
właściwości mechaniczne
wapienie jurajskie
Wyżyna Krakowsko-Wieluńska
crushed aggregate
shape of grain
fracture
mechanical properties
Jurassic limestone
Kraków-Wieluń Upland
Opis:
The paper presents results of investigations on the influence of joint and micro-fractures on the shape of a crushed grain - one of the most important parameter of the quality of crushed aggregate. Three structural types of the Jurassic limestone exploited in the Nielepice deposit nearby Kraków (Poland) were analysed. Cuboidal samples of platy and bedded limestones formed as intra-bio-micrite and intra-bio-sparite were subjected to recurrent cycles of mechanical stress and freeze-thaw process with the aim of inducing fractures. Their directions and frequency were determined by the microscopic observation and by the measurements of longitudinal ultrasonic waves velocities. Crushed and fractionated rock material was used in investigation of grain shape. Three diameter of each grain were measured. Calculated ratios of elongation and flatness have been presented on the Zingg diagrams. Generally, grains of the crushed aggregate from Nielepice are flat, the most in the platy limestones. Isometric grains are less frequent in finer fractions. The structure and texture of rock affect significantly the shape of the finest grains. The shape and dihedral angles of aggregate grains have been compared to the elementary fracture cell, which resulted from the intersection of the joint surfaces observed in the quarry. The same shape is reproduced in the subsequent fractions of the grains. Thin sections were cut parallel to the directions of the main joint sets. Their investigation revealed micro-fractures elongated in the same directions. Distances between them range from the micrometers to centimeters. Changes of velocity of longitudinal ultrasonic waves triggered by rock fatigue process correspond with the shapes of grains of various fractions. Pre-existing cracks and their later opening may cause developing of specific shape of the grains. The influence of new fractures on the aggregate quality has been also stated by significant growth of water absorption measured before and after process of rock fatigue. The apparent density difference was smaller.
Artykuł przedstawia wyniki badań nad wpływem ciosu i mikrospękań na właściwości kruszywa rozpatrywanego jako jego kształt. Badaniom poddano trzy odmiany teksturalne wapieni jurajskich eksploatowanych ze złoża Nielepice w pobliżu Krakowa (Polska). Prostopadłościenne próby wapieni płytowych i uławiconych wykształcone jako intra-bio-mikryt i intra-bio-sparyt poddawano wielokrotnym cyklom ściskania i mrożenia w celu wywołania spękań. Kierunki ich pojawiania się oraz częstotliwość określano na podstawie obserwacji mikroskopowych oraz badań prędkości fal ultradźwiękowych w różnych kierunkach. Badania kształtu ziaren kruszywa wykonywano na podstawie materiału pokruszonego w laboratorium i podzielonego na frakcje. Dla każdego ziarna wykonano pomiar długości trzech prostopadłych do siebie osi. Obliczone na ich podstawie współczynniki wydłużenia i spłaszczenia przedstawiono na diagramach Zingga. Generalnie ziarna kruszywa łamanego z Nielepic wykazują spłaszczenie, szczególnie dla wapieni płytowych. Ilość ziaren izometrycznych zmniejsza się w drobniejszych frakcjach. W ziarnach najdrobniejszych na ich kształt wpływa w dużej mierze struktura i tekstura skały. Kształt i dwuścienne kąty ziaren kruszywa porównano z kształtem spękaniowej komórki elementarnej, wynikającym z przecięcia powierzchni spękań ciosowych pomierzonych w wyrobisku. Kształt ten jest powielany wielokrotnie w coraz mniejszych frakcjach. Szlify mikroskopowe zostały wycięte równolegle do kierunków głównych zespołów spękań. Ich badania wykazały obecność mikrospękań rozciągających się w tych kierunkach w odległościach od milimetrów do centymetrów. Tendencja zmian prędkości fal ultradźwiękowych materiału poddawanego męczeniu znajduje swoje odbicie w tendencji zmian kształtu kruszywa określanego dla różnych frakcji. Istnienie założonych spękań i ich późniejsze otwieranie może doprowadzić do powstania ziaren o określonym kształcie. Wpływ pojawiania się nowych spękań na jakość kruszywa został określony także poprzez istotny wzrost nasiąkliwości wagowej skał przed i po procesie ich męczenia. Różnica w gęstości pozornej była mniejsza.
Źródło:
Gospodarka Surowcami Mineralnymi; 2010, 26, 4; 89-108
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stanu technicznego wielorodzinnego budynku mieszkalnego z podaniem sposobu naprawy
Analysis of the technical condition of a multi-family residential building specifying the repair method
Autorzy:
Grochowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/161963.pdf
Data publikacji:
2014
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek mieszkalny
konstrukcja murowa
stan techniczny
ściana ceglana
spękanie
analiza przyczyn
zalecenia naprawcze
residential building
masonry structure
technical condition
brick wall
cracking
cause analysis
repair recommendation
Opis:
Opisywany obiekt jest budynkiem mieszkalnym, wielorodzinnym i jest zlokalizowany w Lubsku w województwie lubuskim. Budynek został wybudowany na początku lat 60-tych ubiegłego stulecia. Jest to budynek trzykondygnacyjny, całkowicie podpiwniczony. Obiekt został wykonany w technologii tradycyjnej. Ściany piwnic i ściany nośne wykonano z cegły pełnej na zaprawie cementowo-wapiennej. Ściany uzupełniające wykonano z bloczków żużlobetonowych, a działowe z cegły dziurawki również na zaprawie cementowo-wapiennej. Ściany zewnętrzne mają grubość 38 cm, wewnętrzne konstrukcyjne są grubości 25 cm. Układ konstrukcyjny budynku jest poprzeczny. Budynek jest ocieplony. (…) W 1983 mieszkańcy budynku zaobserwowali zarysowania na zewnątrz i wewnątrz budynku co skutkowało zleceniem wykonania ekspertyzy dotyczącej spękania ścian budynku. Zakres opracowania obejmował: inwentaryzację architektoniczno-konstrukcyjną budynku, orzeczenie techniczne dotyczące spękania ścian budynku oraz wnioski i zalecenia.
The multi-family residential building described is located in Lubsko, Lubuskie Voivodeship. It was constructed at the beginning of the 1960s. It is a three-storey building with a basement under the entire structure, executed using traditional technology. Basement walls and load-bearing walls were constructed from solid brick with cement and lime mortar. The material for complementary walls was breeze-block and for partition walls – perforated brick also with cement and lime mortar. External walls are 38 cm thick, whereas internal structural walls – 25 cm thick. The building’s structural system is transversal. It is thermally insulated. (…) In 1983, the residents observed scratches on the external and internal walls, which resulted in the performance of the evaluation of the cracking of building’s walls. The report’s scope included: building’s architectural and structural condition survey, technical opinion concerning the cracking of the walls of the building as well as conclusions and recommendations.
Źródło:
Przegląd Budowlany; 2014, R. 85, nr 2, 2; 51-57
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienia trwałości w projektowaniu konstrukcji żelbetowych
Issues of durability in the design of reinforced concrete structures
Autorzy:
Zybura, A.
Śliwka, A.
Powiązania:
https://bibliotekanauki.pl/articles/161021.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja żelbetowa
trwałość
EC 2
Eurokod 2
oddziaływanie środowiska
spękanie
korozja zbrojenia
ochrona przed korozją
nadbeton
reinforced concrete structure
durability
Eurocode 2
environmental impact
crack
reinforcement corrosion
corrosion protection
concrete cover
Opis:
Przedstawiono zasady zapewnienia trwałości projektowanym konstrukcjom żelbetowym w ścisłym nawiązaniu do zapisów Eurokodu 2. Omówiono ogólne warunki ochrony przed niekorzystnym działaniem środowiska oraz wpływ jakości betonu, grubości otuliny i szerokości rozwarcia rys na zabezpieczenie zbrojenia przed korozją. Przedstawiono przebieg procesów korozji zbrojenia i wewnętrznej korozji betonu. Określono sposób zabezpieczenia zbrojenia otuliną betonową oraz podano ogólną charakterystykę specjalnych środków ochronnych.
The principles of ensuring durability of designed reinforced concrete structures in the strict reference to Eurocode 2 were presented. The general conditions of protection against unfavorable environmental impact and the influence of concrete quality, thickness of the concrete cover and crack width on protection of reinforcement against corrosion were discussed. The course of corrosion processes of reinforcement and internal corrosion of concrete is presented. The method of reinforcement protection with concrete cover was specified and general characteristics of special protective measures were given.
Źródło:
Przegląd Budowlany; 2018, 89, 10; 15-21
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies