Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "solar PV systems" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Common mode behavior in grid connected DC and AC decoupled PV Inverter topologies
Autorzy:
Sundar, D.J.
Kumaran, M.S.
Powiązania:
https://bibliotekanauki.pl/articles/141723.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed generation
common mode leakage current
solar PV systems
transformerless PV inverters
Opis:
The transformer-less grid connected inverters are gaining more popularity due to their high efficiency, very low ground leakage current and economic feasibility especially in photovoltaic systems. The major issue which surfaces these systems is that of common mode leakage current which arises due to the absence of an electrical transformer connected between the inverter and the utility grid. Several topologies have evolved to reduce the impact of common mode leakage current and a majority of them have succeeded in eliminating the impacts and have well kept them within the limits of grid standards. This paper compares and analyses the impact of the common mode leakage current for four popular inverter configurations through simulation of the topologies such as H5, H6, HERIC and FBZVR inverters.
Źródło:
Archives of Electrical Engineering; 2016, 65, 3; 481-493
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Optimal Power Point Tracking Algorithm in a Solar PV Generation System
Algorytm śledzenia optymalnego punktu mocy maksymalnej w systemach fotowoltaicznych
Autorzy:
Hussan, Reyaz
Kumari, Manita
Sarwar, Adil
Iqbal, Atif
Tariq, Mohd
Guziński, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/952936.pdf
Data publikacji:
2019
Wydawca:
ENERGA
Tematy:
solar PV systems
maximum power point tracking
boost converter
system fotowoltaiczny
śledzenie punktu mocy maksymalnej
przekształtnik podwyższający napięcie
Opis:
The non-linearity in I-V characteristics of a PV panel requires to be operated at knee point to extract maximum power. In order to operate the panel at optimal point, maximum power point tracking (MPPT) algorithm is employed in the control structure. The main objective of MPP tracking is to keep the operation at knee point of I-V characteristics under varying condition of temperature and solar insolation. Under non uniform solar PV insolation falling on PV panels connected in series, a partial shading condition (PSC) occurs under cloud or shadow effects causes multiple power peak formation. The conventional MPPT methods fail to converge at global maximum power point (GMPP) under the PSC condition. Occurrence of these multiple peaks on characteristics of P-V makes tracking very difficult and requires integration of an efficient algorithm that differentiates between global and local maximum power point. This paper proposes a variable structure constant voltage method to overcome the problem faced by conventional MPPT methods. Moreover, quadratic boost converter has been taken for MPPT operation for increasing the effective gain of the converter. The effective operation of control algorithm has been validated in simulation results.
Na skutek nieliniowości charakterystyk I-U panelu fotowoltaicznego jego maksymalną moc uzyskuje się, gdy pracuje on w punkcie przegięcia. Aby panel pracował w optymalnym punkcie, w strukturze sterowania należy zastosować algorytm śledzenia punktu mocy maksymalnej (ang. maximum power point tracking – MPPT). Głównym celem śledzenia MPP jest utrzymanie działania panelu PV w punkcie przegięcia charakterystyki I(U) (w tzw. kolanie) niezależnie od zmian temperatury i nasłonecznienia. Pod wpływem częściowego zacienienia paneli fotowoltaicznych połączonych szeregowo (ang. partial shading conditio – PSC), np. z powodu zachmurzenia, na charakterystyce I(U) powstaje kilka punktów przegięcia. Konwencjonalne metody MPPT nie prowadzą do zbieżności w globalnym punkcie mocy maksymalnej (ang. global maximum power point – GMPP) w warunkach PSC. Występowanie kilku szczytów na charakterystyce P(U) bardzo utrudnia śledzenie optymalnego punktu pracy i wymaga użycia takiego algorytmu sterowania, który rozróżnia globalne i lokalne punkty mocy maksymalnej. W celu rozwiązania tego zagadnienia zaproponowano w artykule układ regulacji o stałym napięciu i zmiennej strukturze sterowania. Aby zwiększyć wzmocnienie napięciowe układu energoelektronicznego, zastosowano podwójny przekształtnik podwyższający napięcie. Skuteczne działanie algorytmu sterowania zostało potwierdzone wynikami symulacji.
Źródło:
Acta Energetica; 2019, 4; 21-32
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies