The transformer-less grid connected inverters are gaining more popularity due
to their high efficiency, very low ground leakage current and economic feasibility especially
in photovoltaic systems. The major issue which surfaces these systems is that of
common mode leakage current which arises due to the absence of an electrical transformer
connected between the inverter and the utility grid. Several topologies have
evolved to reduce the impact of common mode leakage current and a majority of them
have succeeded in eliminating the impacts and have well kept them within the limits of
grid standards. This paper compares and analyses the impact of the common mode leakage
current for four popular inverter configurations through simulation of the topologies
such as H5, H6, HERIC and FBZVR inverters.
Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies