Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "skin temperature" wg kryterium: Temat


Tytuł:
Long term effect of Step Aerobics Training on skin temperature. A pilot study
Autorzy:
Zuzda, J.G.
Sillero-Quintana, M.
Dziura, J.
Latosiewicz, R.
Tungthongchai, O.
Rosenberg, E.
Powiązania:
https://bibliotekanauki.pl/articles/1918941.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Thermography
Step Aerobics Training
Skin temperature
Exercise
Opis:
The purpose of this study was to evaluate the effects of a Step Aerobics Training (SAT) on the skin temperature (Tsk) in different regions (ROI) of the anterior body surface. The study included 15 healthy volunteers of the Bialystok University of Technology (BUT) without any previous experience in SAT training. Two sets of thermograms were recorded before and immediately after exercise at the first and last sessions of a 30-weeks SAT program with a progressive intensity. The results indicate a generalized drop in body temperature immediately after exercise with ΔTsk values of -2.45ºC registered immediately after the first training and lower drops (ΔTsk = -1.69ºC) after the 30 weeks of SAT. The regions with lower values of post- vs pre-exercise Tsk were the thighs both in the first session and in the last session of the 30-weeks SAT program. The results show non-significant variations for asymmetries between the values of the contralateral ROIs in every moment of the data collection. We concluded that a 30-week SAT program resulted in significant drop of mean Tsk of evaluated body parts (ROI), being the thermal effects related with the areas more activated in the sport practice. From the thermal asymmetries perspective, the training program carried out did not generate any injury risk for the participants.
Źródło:
Progress in Health Sciences; 2020, 10(2); 65-73
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of individual finger skin temperature on vibrotactile perception threshold
Autorzy:
Harazin, Barbara
Harazin-Lechowska, Agnieszka
Kałamarz, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2179067.pdf
Data publikacji:
2013-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
vibrotactile perception threshold
finger skin temperature
women
men
Opis:
Objectives: In healthy people, the vibrotactile perception threshold (VPT) at fingertips depends on a given measurement method and on individual characteristics such as age, gender and finger skin temperature. The aim of the study was to compare the VPT values in 2 groups of healthy subjects with different finger skin temperature. Materials and Methods: The study group comprised 56 males and 76 females, who formed pairs matched with respect to age, gender and body mass index (BMI) but differing in terms of finger skin temperature at pre-launch testing. The finger skin temperature of less than 29°C indicated the subjects with "cold hands" and that of more than 29°C, the subjects with "warm hands". The measuring system made use of P8 pallesthesiometer (EMSON-MAT, Poland) and the measurement procedure was in compliance with the ISO 13091-1:2001 standard. VPT measurements were performed for the index, middle and ring fingers of both hands at the frequencies of 4 Hz, 25 Hz, 31.5 Hz, 63 Hz, 125 Hz and 250 Hz. Results: The findings of the study revealed that the mean VPTs among the subjects with "cold hands" were significantly higher than the corresponding values among the subjects with "warm hands". Conclusions: The type of individual peripheral thermoregulation should be considered when assessing the VPT and determining its reference values.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 6; 930-939
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiany powierzchniowej temperatury ciała po krótkotrwałej aplikacji i usunięciu elastycznego plastra stosowanego w kinesiotapingu
The changes of the superficial body temperature after short-term application and removal of elastic tape used in kinesiotaping
Autorzy:
Konieczny, G.
Soroko, M.
Ptak, A.
Kuciel, N.
Powiązania:
https://bibliotekanauki.pl/articles/261113.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
termografia
kinesiotaping
temperatura ciała
podrażnienie
thermography
skin temperature
irritation
Opis:
Termografia jest metodą diagnostyczną stosowaną w bezinwazyjnej rejestracji i wizualizacji rozkładu temperatur na powierzchni ciała. Dzięki termografii możliwa jest m.in. ocena przeciążeń treningowych u sportowców oraz analiza termicznej reakcji tkanek miękkich na mechaniczne odkształcanie. Celem pracy była analiza zmian powierzchniowej temperatury ciała po krótkotrwałej aplikacji i usunięciu elastycznego plastra stosowanego w kinesiotapingu. Miało to posłużyć określeniu metody usuwania plastra, która najmniej wpływa na wzrost powierzchniowej temperatury ciała. W badaniu uczestniczyło 47 osób, których średnie BMI (Body Mass Index) wyniosło 20,85 kg/m2. Pomiary wykonywano pięciokrotnie: przed aplikacją plastrów (badanie 1), zaraz po odklejeniu plastra (badanie 2), 10 sekund (badanie 3), 30 sekund (badanie 4) i 60 sekund (badanie 5) po odklejeniu plastra. W badaniach wykorzystano elastyczny plaster Kinesio Tex oraz sztywny plaster marki Omnifix. Analiza zmian rozkładu temperatury powierzchni ciała w zależności od metody usuwania plastra (metoda szybka i wolna) w większości przypadków nie wykazała istotnych statystycznie różnic. Zanotowano istotnie statystycznie niższą temperaturę badanej okolicy ciała po usunięciu plastra Kinesio Tex, w porównaniu z plastrem sztywnym.
Thermography is a noninvasive diagnostic method applied in detection and visualization of superficial body temperature distribution. It is helpful in detection of sport overloads and the analysis of thermal reaction of soft tissues on mechanical deformation. The objective of this study was to analyze the changes of superficial body temperature after short-term application and removal of elastic tape used in kinesiotaping. The analysis was performed to define a method of such tape removal which would cause the minimal increase of superficial body temperature. The study included 47 students, with mean BMI (Body Mass Index): 20,85 kg/m2. The measurements were taken 5 times: before plaster application (1st measurement), after plaster removal (2nd measurement), after: 10 seconds (3rd measurement); 30 seconds (4th measurement) and 60 seconds (5th measurement) of plaster removal. The elastic plaster Kinesio Tex and stiff Omnifix plaster, were applied. The analysis of superficial body temperatures changes, depending on applied method of plaster removal (slowly and quickly), in most cases did not reveal statistically significant differences. The examination of body surface temperature distribution revealed the statistically significant lower temperature of measured area after removal of Kinesio Tex plaster, comparing to stiff plaster.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 3; 182-185
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termowizyjna analiza zmian temperatury powierzchni skóry po zabiegu sauny suchej u osób zdrowych
Thermovision analysis of the skin temperature changes after sauna exposition in healthy subjects
Autorzy:
Zalewski, P.
Pawlak, J.
Klawe, J.
Tafil-Klawe, M.
Lewandowski, A.
Panowicz, I.
Powiązania:
https://bibliotekanauki.pl/articles/261095.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
sauna sucha
termowizja
temperatura skóry
finnish sauna
thermovision
skin temperature
Opis:
Sauna sucha (fińska) jest zabiegiem ciepłoleczniczym, stosowanym powszechnie od wielu lat na całym świecie. Celem pracy było przedstawienie wstępnych wyników badań w zakresie termowizyjnej analizy wpływu zabiegu sauny suchej na dynamikę zmian temperatury w obrębie wybranych obszarów powierzchni ciała. Powierzchniowy efekt ogrzania organizmu na skutek zabiegu w suchej saunie (fińskiej) jest różny w różnych miejscach na ciele pacjenta. W pracy wykazano, że w badanych obszarach ciała już po 40 minutach od zabiegu w saunie obserwowano powrót do zakresu temperatur zarejestrowanych przed zabiegiem.
Finnish sauna offers a thermotherapy treatment, well known worldwide. The aim of the study was to present the preliminary report concerning the influence of Finnish sauna on skin body temperature changes. The thermovision analysis revealed the statistically significant differences between mean temperatures after application of sauna. Thermovision examination confirmed that 40 minutes after sauna, the body temperature, returned to the initial value.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2011, 17, 1; 36-43
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ bodźca stresujacego na temperaturę skóry człowieka
Human skin temperature after stressing stimulus
Autorzy:
Dziuban, E.
Powiązania:
https://bibliotekanauki.pl/articles/157999.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
temperatura skóry
pirometr podczerwieni
bodziec elektryczny
skin temperature
IR pyrometer
electrical stimulus
Opis:
Przedstawiono wstępne wyniki badań polegających na poszukiwaniu mierzalnych parametrów fizykalnych reakcji organizmu człowieka poddanego stresowi. Eksperyment polegał na pomiarze temperatury pirometrem radiacyjnym w punktach skóry odległych od miejsca przykładania wstrząsu elektrycznego. Stwierdzono, że pod wpływem stresu w mierzonych miejscach nastąpiło obniżenie wartości temperatury od 0,09°C do 0,5°C w stosunku do stanu przed stymulacją. Wyniki takich badań mogą znaleźć zastosowanie w diagnozowaniu i terapii medycznej oraz identyfikowaniu osób działających pod wpływem stresu.
This investigation examined the influence of electrical stress on regional skin temperature. An IR pyrometer measured skin temperature on left palm, while right palm was electrical stimulated. In span of ca 3 min registration temperature before, during and after stimulation was acquired of 3 subjects. Preliminary results revealed temperature decrease of 0.09°C .... 0.5°C. This finding would be valuable in medical diagnosis and therapy as well as in biometrics identification persons under stress.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 41-42
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of occupation hot exposure in industrial workplaces in a subtropical country
Autorzy:
Yang, Yu-Chiao
Wei, Ming-Chi
Hong, Show-Jen
Powiązania:
https://bibliotekanauki.pl/articles/2161875.pdf
Data publikacji:
2017-05-08
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
skin temperature
heart rate
heat stress
wet bulb globe temperature
maximum allowable exposure time
metabolic rate
Opis:
Objectives The objective of this study has been to evaluate the occupational heat exposure of 12 workers at 5 plants in a subtropical country. Material and Methods The heat stresses and strain on workers in 5 plants were assessed by the International Organization for Standardization (ISO) 7243 index (wet bulb globe temperature – WBGT) and the ISO 7933 index (maximum allowable exposure time – $ \text{D}_\text{lim} $). Results Results indicated that 42% of the subjects (5 workers) surpassed the WBGT limits. According to the $ \text{D}_\text{lim} $, 42% of the subjects could not continue working in the hot environments. The relationships between the various heat stress indices and the WBGT index were also correlated. However, further studies from different heat environments and more subjects should be performed. Conclusions The sensitive dependence of skin temperature on meteorological and physiological indices for each subject was clearly observed. Obviously, the heart rate response to metabolic rate was much greater than that caused by environmental heat alone. The exponential relationship between workers’ duration-limited exposure time, predicted by various estimated criteria, and WBGT were also found. Int J Occup Med Environ Health 2017;30(3):379–395
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 3; 379-395
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Comparison of Skin Temperatures and Clothing Microclimate During Moderate Intermittent Exercise in the Cold Between One and Two Layers of Cotton and Polypropylene Underwear
Autorzy:
Ha, M.
Tokura, H.
Yoden, K.
Holmer, I.
Powiązania:
https://bibliotekanauki.pl/articles/90615.pdf
Data publikacji:
1998
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
mean skin temperature
clothing microclimate
cotton
polypropylene
underwear
średnia temperatura skóry
bawełna
ubranie
polipropylen
Opis:
The purpose of this study was to compare the effects of 2 kinds of underwear made from hydrophobic and hydrophilic fabrics on the mean skin temperatures and clothing microclimate (temperature, humidity) in participants performing intermittent exercise in cold environmental conditions. One or 2 layers of cotton underwear (C1, C2) with a 2-piece long-sleeved shirt and long-legged trousers, and 1 or 2 layers of polypropylene underwear (P1, P2) with a 2-piece long-sleeved shirt and long-legged trousers were used as experimental underwear. In addition, the participants wore a 2-piece ski suit as 100% polyester clothing including 100% polyester padding. Ten young adult females volunteered as participants. The experiments were performed in a climatic chamber at an ambient temperature (Ta) of 0°C and an air velocity of 0.26 m s-1. The major findings are summarized as follows: (a) Although the clothing microclimate humidity was not different within the ski suit of outer clothing between C1 and P1, it was significantly higher in P2 than in C2; (b) Clothing microclimate temperature inside the ski suit did not differ between C1 and P1, whereas it was significantly higher in P2 than in C2; (c) The thermal gradient between innermost and outermost of clothing microclimate at back level did not show any difference between C1 and P1, but it was significantly higher in C2 than in P2. These results are discussed in terms of thermal physiology and clothing sciences.
Źródło:
International Journal of Occupational Safety and Ergonomics; 1998, 4, 3; 347-362
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary fizykalnych parametrów organizmu
Organism`s physical parameters measurements
Autorzy:
Dziuban, E.
Powiązania:
https://bibliotekanauki.pl/articles/154700.pdf
Data publikacji:
2003
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary parametrów biomedycznych
bezdotykowy pomiar temperatury skóry
biomedical measurements
non-contact skin temperature measurements
Opis:
Pomiary "in vivo" fizykalnych parametrów organizmu ludzkiego wymagają rozwiązania licznych trudności metrologicznych i technicznych. Wiążą się one z małym poziomem mocy oraz wąskim zakresem częstotliwości i obecności składowej stałej, tak charakterystycznymi dla wielkości mierzonych w biomedycynie oraz interferencjami i zakłóceniami pochodzacymi od innych organów i od otoczenia. Zasadniczą wagę ma ponadto zapewnienie bezpieczeństwa pacjenta. Na tle zwięźle przedstawionych problemów, jakie stwarzają metrologom pomiary w biomedycynie zaprezentowano przykład zastosowania bezdotykowego pomiaru temperatury do badania odpowiedzi termicznej wywołanej przez nakłuwanie wykonywane w punktach biologicznej aktywności.
Measurement organism`s physical parameters cause special metrological and technical problems. They occur because: a) signals collected from the human organism have low power and narrow frequency band, b) signals originated from the organs interfere useful signal, c) disturbances in clinical environment make dificult receiving biomedical signals, d)both noninvasive and invasive measurements should provide absolute electrical shock protection. For example results of non-contact measurements of temperature changes evoked by needle therapy at biological active points are presented.
Źródło:
Pomiary Automatyka Kontrola; 2003, R. 49, nr 7-8, 7-8; 26-28
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the effect of intermittent type of mental work-load by physiological psychological index
Autorzy:
Mizuno, T.
Nomura, S.
Nozawa, A.
Asano, H.
Ide, H.
Powiązania:
https://bibliotekanauki.pl/articles/333172.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
mentalne obciążenie pracą
mental workload
fasal skin temperature physiological psychological evaluation
intermittent type of MWL
Opis:
This paper was aimed at evaluating the mental work-load (MWL) with psycho-physiological indices. Especially, we focused on the intermittent type of MWL, which is assumed as a predisposing factor of various somatic and mental disorders. In the experiment, we introduced a facial skin thermo image comparing with conventional physiological indices, such as electrocardiogram (ECG) and electroencephalogram (EEG). As a result, the facial skin image was suggested to be a useful tool for evaluating such an intermittent type of MWL.
Źródło:
Journal of Medical Informatics & Technologies; 2009, 13; 249-253
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Future Trends in the Development of Thermal Manikins Applied for the Design of Clothing Thermal Insulation
Przyszłe trendy w rozwoj manekinów termicznych stosowanych do projektowania izolacyjności cieplnej odzieży
Autorzy:
Bogdan, A.
Zwolińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/232505.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
manekin termiczny
temperatura skóry
izolacja termiczna
odzież ochronna
thermal manikin
skin temperature
thermal insulation
protective clothing
Opis:
Thermal manikins were created with the intention to design and model protective clothing insulation for specific conditions, e.g. military clothing and clothing for divers. At present thermal manikins have a broader use, i.e. to assess the effect of clothing on a human body, to assess its influence on thermal comfort during work in a given clothing ensemble and to test innovative solutions bringing about a reduction in the thermal heat load. When using thermal manikins it should be borne in mind that heat exchange through clothing is, to a large extent, determined by the temperature distribution on human skin. The aim of the study was to find out to what extent thermal manikins can be used to represent the correct distribution of temperature on human skin. To this end, comparative measurements of the temperature distribution on the surface of a standard thermal manikin with a structure generally used and on the surface of the skin of volunteers were performed. The tests conducted showed that for the further development of thermal manikins computer software should be developed which would help to predict the temperature distribution on the manikin surface corresponding to the skin temperature of volunteers. Such software should allow for the simulation of thermal regulatory mechanisms in a human, i.e. an increase in skin temperature caused by vasoconstriction and shivering, as well as a decrease in skin temperature due to vasodilatation and sweating. In a thermally neutral environment, the methods which are currently used to control the thermal manikin seem to be sufficient.
Termiczne manekiny zostały opracowane w celu projektowania i modelowania izolacyjności cieplnej odzieży ochronnej. Obecnie manekiny termiczne mają szerokie zastosowanie badawcze. Stosując manekiny termiczne należy pamiętać, że wymiana ciepła przez odzież zależy w dużej mierze od rozkładu temperatury skóry człowieka. Celem badań przedstawionych w artykule było sprawdzenie, w jakim stopniu manekiny termiczne mogą być używane do prognozowania prawidłowego rozkładu temperatury skóry człowieka. W tym celu przeprowadzono badania porównawcze rozkładu temperatury na powierzchni standardowego manekina termicznego powszechnie stosowanego w wielu laboratoriach badawczych i na powierzchni skóry ochotników. Przeprowadzone testy wykazały, że rozwój manekinów termicznych powinien być ukierunkowany w celu opracowania odpowiedniego oprogramowania komputerowego, które byłyby pomocne do prognozowania rozkładu temperatury na powierzchni manekina odpowiadającego temperaturze skóry ochotników.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 4 (93); 89-95
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies