Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sewage treatment" wg kryterium: Temat


Tytuł:
Cod Fractions Changes During Sewage Treatment With Constructed Wetland
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/123349.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD
sewage treatment
wetland
Opis:
The purpose of the presented research work was to find out COD fractions in raw wastewater and during treatment with constructed wetland (CW) system. The tests were performed in CW system with average flow of about 4 m3/day. In raw wastewater the highest concentration of fraction in organic suspended solid easy biodegradable (XS – 250 mg O2/l) was observed. The same situation was with dissolved organic easy biodegradable matter (SS – 250 mg O2/l). Lower quantity of non-biodegradable fractions dissolved and in suspended solids were observed (SI – 27 mg O2/l, XI – 83.33 mg O2/l). More than 80% of total COD was as biodegradable fractions (SS + X). After treatment with CW system the highest concentration was observed for dissolved non biodegradable fraction (SI – 27 mg O2/l). Lower concentration was for biodegradable fraction in suspended solid (XS – 3.33 mg O2/l). More than 89% of total COD was in biological non-biodegradable fraction (SI + XI).
Źródło:
Journal of Ecological Engineering; 2015, 16, 3; 43-48
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of pollutant elimination in the Dobra treatment plant
Autorzy:
Nowak, J.
Chmielowski, K.
Chmielowska, B.
Bedla, D.
Powiązania:
https://bibliotekanauki.pl/articles/101622.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage treatment plant
domestic sewage
SBR
Opis:
This study was aimed to conduct an analysis of the efficiency of pollutant elimination in the Dobra treatment plant, which operates based on the SBR reactor. The object purifies domestic sewage and pre-treated industrial sewage from a slaughterhouse within the Dobra municipality. The source material for the analysis comprised the values of pollution indicators: BOD5 , CODCr, total suspended solids (TTS) in raw sewage (19 samples) and treated sewage (34 samples). The results of chemical analyses were obtained in the period 2007-2014. The results were compared with the limit values imposed by the Regulation (2014). The coefficient of reliability of the treatment plant was also calculated in this study. The average efficiency of pollutant elimination in the treatment plant was: BOD5 - 98.6%, CODCr - 94.9%, total suspended solids - 97.6%. These results demonstrate that the studied facility operates flawlessly and the treatment efficiency is high. On the other hand, the reliability coefficient values indicate that the operation of this object is unstable.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, III/1; 737-747
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski
Autorzy:
Chmielowski, K.
Wąsik, E.
Operacz, A.
Bugajski, P.
Kaczor, G.
Jurik, L.
Powiązania:
https://bibliotekanauki.pl/articles/101267.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage biodegradation
sewage composition
sewage treatment plant
Opis:
The paper presents an analysis of sewage susceptibility to biodegradation on an example of sewage treatment plant in Wodzisław Śląski in the Śląskie province. For this purpose, dependencies between selected indices of domestic sewage pollution were applied. Descriptive statistics of the respective indices rations COD/BOD5 , BOD5 /TN, BOD5 /TPwere presented. Moreover, an analysis was conducted on the composition of raw sewage flowing into the treatment plant, pre-treated sewage and sewage leaving the studied treatment plant. The analysis was carried out on the basis of three basic indices of sewage pollution (BOD5 , COD and total suspended solids) and two biogenic indices (total nitrogen and total phosphorus). Tests on the sewage composition were conducted in the years 2010-2015. Basic descriptive statistics were compiled for the values of the studied indices of sewage pollution and the obtained results were interpreted. On the basis of collected material it may be said that sewage reaching the treatment plant in Wodzisław Śląski revealed a good susceptibility to biodegradation, whereas the BOD5 /TN and BOD5 /TP ratios were below the optimum value.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1427-1443
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability of sewage treatment plants processing sewage from school buildings located in non-urban areas
Autorzy:
Bugajski, P.
Almeida, M. A. A.
Kurek, K.
Powiązania:
https://bibliotekanauki.pl/articles/101488.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage
reliability
on-site sewage treatment facility
Opis:
The aim of this study was to assess the reliability of two on-site sewage treatment facilities (BCT S-12 and TJ EP-4) serving two school buildings located in rural communes in Małopolska region. The reliability was determined using Weibull reliability method. The research was conducted for 24 months and it involved the collection and analysis of 48 samples of raw and treated sewage from each facility. The analyses included organic and biogenic pollution, i.e. BOD5 , COD, and total nitrogen. Reliability assessment revealed the following effectiveness for BCT S-12 facility: 77% for BOD5 , 96% for COD and 25% for total nitrogen. For TJ EP-4 facility, the effectiveness was 81%, 88% and 72% for BOD5 , COD and total nitrogen, respectively. Both facilities used the activated sludge process and experienced periodic disturbances in the treatment flow that resulted in reduced sewage treatment efficiency. Considering the above, the processes of nitrification and denitrification in the biological reactor should be streamlined to provide more effective removal of organic and nitrogen-based compounds in the investigated facilities.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/3; 1547-1557
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current State of Communal Sewage Treatment in the Republic of Kazakhstan
Autorzy:
Andraka, D.
Ospanov, K.
Myrzakhmetov, M.
Powiązania:
https://bibliotekanauki.pl/articles/124515.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewage treatment
sewage characteristics
decentralized systems
sustainability
Opis:
Protection of water environment from pollution is one of the major tasks in the contemporary world. Nowadays, in the Republic of Kazakhstan ecological situation concerning sewage treatment remains deficient. Raw sewage is often discharged directly onto filtration beds or landfills. Many existing wastewater treatment facilities in cities are in unsatisfactory technical conditions. In many villages and small settlement units the problem of treatment and disposal of sewage sludge from treatment facilities also requires urgent solutions. In this article, the current state of communal sewage treatment in the Republic of Kazakhstan is shown. The technical and technological characteristics of sewage disposal systems, including the cities of Almaty and Astana, are presented. This article is especially aimed at identification of environmental problems related with sewage treatment in the Republic of Kazakhstan.
Źródło:
Journal of Ecological Engineering; 2015, 16, 5; 101-109
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza skuteczności działania oczyszczalni ścieków pracującej w systemie SBR
Performance analysis of sewage treatment plant working in the SBR system
Autorzy:
Bartkowska, I.
Klaus, W.
Powiązania:
https://bibliotekanauki.pl/articles/908416.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
gospodarka ściekowa
projektowanie oczyszczalni
oczyszczalnia ścieków
skuteczność oczyszczania ścieków
sewage treatment
biological sequencing batch reactor
designing sewage treatment plant
sewage treatment plant
effluent treatment effect
Opis:
Technologia oczyszczania ścieków osadem czynnym w systemach porcjowych znana już była na początku XX wieku. W 1912 roku Fowler zastosował do oczyszczania ścieków miejskich w Manchesterze napowietrzanie ścieków strumieniem pęcherzyków powietrza wytwarzanych w sposób pneumatyczny wraz z następującym po nim etapem sedymentacji. W 1914 roku studenci Fowle'a – Ardern i Lockett – zaprezentowali oczyszczanie ścieków w systemie z napełnianiem i dekantacją bez pozbywania się biologicznych osadów nagromadzonych w czasie cyklicznego napowietrzania ścieków.
This paper presents an assessment of wastewater treatment plants operating in the technological sequence of biological reactors (SBR) as an example Olecko. This paper presents qualitative characteristics of raw sewage to the treatment plant infl uent and effl uent. Assesses the work of the treatment on the basis of tests erformed and operating experience. The analysis is based on the results of the following indicators of pollutants: OD5, COD, pH, concentration of total nitrogen, total phosphorus and total suspended solids. A description of modernized in 2009 technology of sewage treatment plant and sewage sludge management was presented.
Źródło:
Ekonomia i Środowisko; 2013, 4; 107-117
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozpoznawanie niekorzystnych zjawisk mogących stwarzać ryzyko w komunalnej oczyszczalni ścieków
Recognition of unfavourable events that may pose a risk on municipal sewage treatment plant
Autorzy:
Łój-Pilch, M.
Zakrzewska, A.
Zielewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/126534.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
identyfikacja ryzyka
urządzenia ciągów technologicznych
oczyszczanie mechaniczne
oczyszczanie biologiczne
oczyszczanie chemiczne
przeróbka osadów ściekowych
risk identification
technological process equipment
mechanical sewage treatment
biological sewage treatment
chemical sewage treatment
sewage sludge treatment
Opis:
Oczyszczalnie ścieków są obiektami technicznymi, których zadaniem jest usunięcie substancji stałych i rozpuszczonych, koloidów oraz zawiesin ze ścieków przed odprowadzeniem ich do odbiornika. Wykorzystuje się w tym celu procesy mechaniczne, biologiczne i chemiczne. W części mechanicznej stosuje się te same podstawowe procesy separacji i sedymentacji, służące do odseparowania cząstek mineralnych i łatwoopadalnych cząstek organicznych, natomiast na technologię części biologicznej i chemicznej mają wpływ (zgodnie z obowiązującym aktualnie rozporządzeniem MŚ) przede wszystkim równoważna ilość mieszkańców (RLM) oraz rodzaj odbiornika. Komunalne oczyszczalnie ścieków można ogólnie podzielić na takie, w których nie zachodzi konieczność usuwania związków biogennych (mogą bazować na technologii złóż biologicznych), oraz takie, w których usuwane są związki azotu i fosforu, bazujące głównie na osadzie czynnym. Dodatkowo, w zależności od jakości ścieków i wymagań odbiornika można stosować doczyszczanie chemiczne. Różnorodność procesów i konstrukcji występujących na oczyszczalni ścieków generuje powstawanie zjawisk stwarzających ryzyko dla podstawowego celu oczyszczalni. Zidentyfikowanie tych zjawisk w poszczególnych elementach ciągów technologicznych stanowi podstawę procesu zarządzania ryzykiem obiektu technicznego.
Wastewater treatment plants are technical facilities designed to remove solids and dissolved solids, colloids and suspensions from wastewater before drainage them to the receiver. For this purpose, mechanical, biological and chemical processes are used. The mechanical section consists of the basic processes used to separate mineral solids and easily settleable organic solids, however the technology of the biological and chemical sections depends on (according to the current Regulation Minister of the Environment) Equivalent number of inhabitants and type of outfall. Municipal sewage treatment plants can generally be divided for those that do not need to remove biogenic compounds (they can be based on the technology of biological filters) and those in which nitrogen and phosphorus compounds are removed, mainly based on activated sludge. Moreover, depending on the quality of the waste water and the requirements of the receiver, chemical sewage treatment can be used. Variety of applied processes and construction at wastewater treatment plants causes the occurrence of unfavourable events that pose a risk to the primary purpose of a treatment plant. Identifying those events is the basis for the risk management process in a technical facility.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 195-201
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Endotoxin exposure in sewage treatment workers: investigation of exposure variability and comparison of analytical techniques
Autorzy:
Spaan, S
Smit, L.A.M.
Eduard, W.
Larsson, L.
Arts, H.J.J.M.
Wouters, I.M.
Heederik, D.J.J.
Powiązania:
https://bibliotekanauki.pl/articles/50638.pdf
Data publikacji:
2008
Wydawca:
Instytut Medycyny Wsi
Tematy:
analytical technique
exposure variability
sewage treatment plant
worker
endotoxin exposure
sewage treatment
endotoxin
waste control
Źródło:
Annals of Agricultural and Environmental Medicine; 2008, 15, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on the Composition and Environmental Impact of Sewage Sludge
Autorzy:
Jumasheva, Kamshat
Syrlybekkyzy, Samal
Serikbayeva, Akmaral
Nurbaeva, Farida
Kolesnikov, Alexandr
Powiązania:
https://bibliotekanauki.pl/articles/24201791.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sludge
sewage treatment plant
wastewater
mapping
Opis:
The article examinee the characteristics of sewage sludge and its impact on the environment. The description of technical installations, sludge sites in the municipal wastewater treatment systems, which are sources of unfavorable sanitary and epidemiological condition of the studied territory, was presented. A detailed analysis of the structure, composition and morphology of sludge sediment was given. It was found that the sludge presents a loose, rough heterogeneous porous structure represented by the presence of a fibrous substrate with amorphous scaly-crystalline inclusions. During laboratory analyses of the composition of the dry residue, the presence of such types of heavy metals as chromium, manganese, nickel, copper, zinc, lead, cobalt, molybdenum, cadmium was revealed. The excess of permissible concentrations of various elements was observed: chromium more than 7.1 at MPC – 6.0 by 1.18 times; copper more than 3.3 at MPC – 3.0 by 1.1 times; zinc more than 27.3 at MPC – 23.0 by 1.18 times; lead more than 34.3 at MPC – 32.0 by 1.07 times; cobalt more than 6.4 at MPC – 5.0 by 1.28 times; molybdenum more than 6.9 at MPC – 5.0 by 1.3 times. Soil analysis revealed a pH of 7.1, which is neutral, may be optimal for plants; the concentration of calcium, iron and chromium does not exceed the established maximum permissible values. When analyzing the air environment of the territory of the treatment facilities, the presence of gaseous pollutants, such as methane, ammonia, nitrogen dioxide, hydrogen sulfide, carbon monoxide, was established. It has been established that anthropogenic sludge landfills are the sources that create a technogenic load on the atmospheric air, polluting it with methane, since the concentration of methane exceeds the MPC by more than 3 times.
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 315--322
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Impact of Sewage Treatment Plant on the Amount of Heavy Metals in Water of the Supraśl River Catchment Area
Autorzy:
Skorbiłowicz, M.
Skorbiłowicz, E.
Wójtowicz, P.
Ofman, P.
Zamojska, E.
Powiązania:
https://bibliotekanauki.pl/articles/123581.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
sewage treatment plant
heavy metals
water
Opis:
The main purpose of this study was to evaluate the effect of treated sewage flowing from sewage treatment plants located in the basin of the Supraśl river on the concentration and load of metals in river waters and its main tributaries. Three measuring- control points were chosen, on the river and its tributaries, located near Gródek, Sokółka and Dobrzyniewo. Selected points were located behind the discharge of treated wastewater from sewage treatment plants respectively – Gródek, Sokółka and Bialystok. The samples of treated sewage and water were collected in a period from May to November, once a month in 2014. Each individual sample was examined for the content of dissolved form of the following metals: Pb2+, Cu2+, Cd2+, Ni2+, Zn2+, Fe2+/3+. After taking into account water flow of the Biała, Sokołda and Supraśl in every month, metals loads expressed in mg·h-1., transported by the Supraśl and its tributaries waters were calculated. In the study monthly metals loads discharged into the Biała, Sokołda and Supraśl by sewage treatment plants in Białystok, Sokółka and Gródek were also calculated. The studies have shown the impact of metals load in treated wastewater on metals loads in waters of studied rivers based on the obtained correlation. Most of the searched relations between loafs of Pb2+ – r = 0,88; Cd2+ – r = 0,98; Fe2+/3+ – r = 0,45; Ni2+ – r = 0,55; Zn2+ – r = 0,86 were obtained in case of wastewater treatment plant in Gródek and Supraśl waters. In the study period we observed a diversity in concentration of Cd2+, Fe2+/3+, Ni2+ and Zn2+ in treated sewage and in river waters, which affected loads of this metals.
Źródło:
Journal of Ecological Engineering; 2016, 17, 1; 136-142
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Biofiltration with Polyurethane Foams for Domestic Sewage Treatment
Autorzy:
Dacewicz, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/124430.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
waste
polyurethane foam
sewage treatment
biofilter
Opis:
The study presents the results of an experimental method for purification of household sewage on the biofilters filled with polyurethane waste in the form of trims of upholstery foam (PUF). We assessed the removal effectiveness of organic compounds, ammonium nitrogen and total suspended solids from sewage pre-treated in a septic tank at hydraulic loading ranging from 31.8 to 229.2 mm-1. The results of five month study identified the biofilter filled with 30 cm thick foam as the most effectively removing BOD5, CODCr, N-NH4+ and total suspended solids. Average reduction in pollutant levels for this filter reached 95%, 94%, 84% and 68%, respectively. PUR foam in the form of trims of upholstery foam filling the vertical flow filters ensured favorable conditions for the development of heterotrophic and nitrifying bacteria without any need for additional aeration.
Źródło:
Journal of Ecological Engineering; 2019, 20, 2; 131-140
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy oczyszczalni ścieków w Hajnówce i propozycja jej modernizacji
Effectiveness of wastewater treatment plants in Hajnówka and its modernization proposal
Autorzy:
Bartkowska, I.
Dzienis, L.
Wawrentowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/401024.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków
unieszkodliwianie osadów ściekowych
projektowanie oczyszczalni
autotermiczna termofilna stabilizacja
sewage treatment
sewage sludge treatment
designing sewage treatment plant
Autoheated Thermophilic Aerobic Digestion
Opis:
W artykule przedstawiono charakterystykę dopływających ścieków surowych oraz ścieków oczyszczonych w oczyszczalni w Hajnówce. Dokonana analiza efektywności pracy przedmiotowej oczyszczalni stała się podstawą do zaprojektowania jej rozbudowy. W pracy przedstawiono opis aktualnej technologii oczyszczania ścieków oraz stan gospodarki osadowej. Przedstawiony został także zaproponowany zakres rozbudowy, który jest wynikiem wcześniej przeprowadzonych analiz wyników badań z lat 2003-2010 oraz wizji lokalnych.
The article presents characteristics of untreated sewage flowing into the sewage treatment plant in Hajnówka, as well as characteristics of treated sewage. An analysis of the sewage treatment plant operation efficiency has become the basis for development design for the plant. The paper describes present sewage treatment technology and state of sludge management. The article also presents a proposed design for development which results from previous research analyses made in 2003-2010 and from site inspections.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 226-235
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in surface water microflora caused by discharge of purified sewage into rivers
Autorzy:
Godela, Agnieszka
Lewańska, Monika
Myga-Nowak, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/1179554.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Sewage
river
sewage treatment plant
sewers
water microflora
Opis:
Progressive environmental degradation results in an increase in the number of waters that do not meet the standards in force. Surface waters are particularly vulnerable to pollution because they are receivers of purified water and agricultural or industrial wastewater flow. In addition, the local increase in temperature and the increase amount and availability of nutrients associated with wastewater discharged improves the microbial growth and thus increase their quantity. The treated sewage must meet certain requirements regarding their physicochemical and biological parameters. However, the regulations do not require to check microbiological quality by treatment plants, so the purpose of the study was to determine the impact of discharge of purified wastewater by the "Warta" sewage treatment plant down to Warta river. The study was conducted in 2008-2016 at three collection points near the place of discharge of purified sewage from Warta SA sewage treatment plant. It has been demonstrated that the process of sewage treatment is not enough in terms of microbiological pollution because the water samples collected at the points behind the discharge site of the effluent into the river were characterized by increased abundance and microbiological diversity.
Źródło:
World Scientific News; 2017, 75; 26-32
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Waste management problems on an example of small sewage treatment plants
Problemy gospodarki osadowej na przykładzie małych oczyszczalni ścieków
Autorzy:
Wira, J.
Wira, D.
Powiązania:
https://bibliotekanauki.pl/articles/85061.pdf
Data publikacji:
2003
Wydawca:
Akademia Pomorska w Słupsku
Tematy:
waste management
small sewage treatment plant
treatment plant
sewage treatment
sludge structure
sludge source
environment contamination
environment pollution
Źródło:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline; 2003, 06
1643-0115
Pojawia się w:
Baltic Coastal Zone. Journal of Ecology and Protection of the Coastline
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola oczyszczalni hydrobotanicznych w oczyszczaniu ścieków z terenów wiejskich
The role of hydrophyte systems in sewage treatment from rural areas
Autorzy:
Lalke-Porczyk, E.
Swiontek Brzezinska, M.
Donderski, W.
Powiązania:
https://bibliotekanauki.pl/articles/339169.pdf
Data publikacji:
2010
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
bakterie wskaźnikowe
oczyszczalnie hydrobotaniczne
oczyszczanie ścieków
stan sanitarny ścieków
hydrophyte sewage treatment plants
indicator bacteria
sanitary state of sewage
sewage treatment
Opis:
Celem badań była ocena skuteczności oczyszczania ścieków bytowo-gospodarczych w małej przydomowej oczyszczalni wierzbowej oraz doczyszczania ścieków w gminnej, mechaniczno-biologicznej oczyszczalni z filtrem piaskowo-trzcinowym. Próbki ścieków do badań pobierano w okresie od maja do grudnia 2007 r. Liczebność bakterii heterotroficznych zdolnych do wzrostu w temperaturze 22°C (jtk 22°C) i 37°C (jtk 37°C) oznaczano metodą płytek lanych zgodnie z normą PN-ISO 6222. Liczebność bakterii z grupy coli (TC) oraz bakterii termotolerancyjnych (fekalnych) z grupy coli (FC) oznaczano metodą fermentacyjną probówkową zgodnie z PN-75/C-04615/05 i PN-77/C-04615/07. Liczebność paciorkowców kałowych [FS] badano metodą filtrów membranowych zgodnie z PN-82/C-04615/25 na podłożu Slanetza-Bertleya. Wykazano znaczne zmniejszenie liczebności większości badanych grup bakterii w trakcie oczyszczania ścieków metodą hydrobotaniczną. W najmniejszym stopniu zmniejszyła się liczebność paciorkowców kałowych.
One of the ways to solve the sewage treatment problems in Polish rural areas is the use of unconventional sewage treatment systems based on ponds with macrophytes or on ground filters with hydrophytes. Their function follows the model of natural wetlands. They are featured by many merits and can be used to treat sewage from single farms, small villages, land estates or agro-tourist centres. Beside abiotic processes such as sedimentation and filtration, sorption of chemical pollutants in the medium and photolytic reactions, an important role in sewage treatment play biological factors - vascular flora and microorganisms in a given object. The aim of this study was to assess the effect of sewage treatment in a small home willow treatment plant and treated sewage polishing in the communal mechanical-biological treatment plant with sand-reed filter. The sewage for analyses was sampled from May to December 2007. The number of heterotrophic bacteria capable of growing at temperatures of 22°C (cfu 22°C) and 37°C (cfu 37°C) was estimated by cast plate method according to Polish standard PN-ISO 6222. The numbers of coliform bacteria [TC] and thermo-tolerant (faecal) coliform bacteria [FC] were estimated by means of fermentation test-tube method according to Polish standards PN-75/C-04615/05 and PN-77/C-04615/07. The number of faecal streptococci (FS) was determined by the membrane filter method according to Polish standard PN-82/C-04615/25 with the use of Slanetz-Bertley medium. Considerable reduction of the majority of investigated bacteria groups was found during hydrophyte sewage treatment. The lowest reduction was observed in the number of faecal streptococci.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2010, 10, 3; 119-127
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies