Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sandblasting" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Studies of stainless steel exposed to sandblasting
Autorzy:
Horodek, P.
Eseev, M. K.
Kobets, A. G.
Powiązania:
https://bibliotekanauki.pl/articles/147075.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
stainless steel
sandblasting
defects
positron beam
Opis:
The influence of sandblasting on surface and subsurface of stainless steel is investigated using variable energy positron beam (VEP), positron annihilation spectroscopy (PAS), scanning electron microscopy (SEM), and atomic force microscopy (AFM). Samples of stainless steel were blasted using 110 μm particles of Al2O3 under different pressure and time duration. In the case of sandblasting for 90 s, the reduction of positron diffusion length depending on the applied pressure was observed. Sandblasting during 30 s leads only to the reduction of positron diffusion length to about 60 nm for all samples. Positron lifetimes close to 170 ps measured using positrons emitted directly from the source point to the presence of vacancies on the dislocation lines. SEM and AFM images show that surface roughness depends rather on pressure of sandblasting than time of exposition.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 721-724
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Powierzchnia implantu tytanowego piaskowanego hydroksyapatytem
Titanium implant surface after hydroxyapatite sandblasting
Autorzy:
Koper, J. K.
Majchrowski, R.
Jakubowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/284168.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
tytan
hydroksyapatyt
piaskowanie
implant
titanium
hydroxyapatite
sandblasting
Opis:
Praca podejmuje tematykę modyfikacji powierzchni tytanu, stosowanego jako biomateriał w implantach tkanek twardych. Tytan pomimo doskonałych właściwości użytkowych, w zastosowaniach implantacyjnych wymaga przygotowania powierzchni o określonej morfologii, parametrach oraz biozgodności. Celem niniejszej pracy było porównanie komercyjnie stosowanych powierzchni tytanu, poddanych procesowi piaskowania proszkiem HA/TCP (HA - hyroksyapatyt, TCP - fosforan trójwapniowy), w zastosowaniach implantacyjnych. Proces piaskowania miał na celu zwiększenie chropowatości powierzchni i jednocześnie zmianę jej składu chemicznego tak, aby sprzyjała wzrostowi i proliferacji komórek kostnych oraz była bardziej biozgodna. W badaniach wykorzystano polerowaną powierzchnię Ti 99,6% piaskowaną nieużywanym (świeżym) proszkiem oraz proszkiem używanym (po zakończonym cyklu produkcyjnym, tzn. wypiaskowaniu 300 elementów/implantów dentystycznych). Uzyskane w ten sposób próbki zbadano z wykorzystaniem mikroskopii SEM oraz profilometru optycznego, w celu określenia morfologii i geometrii powierzchni. Wyznaczono 11 parametrów 2D/3D, charakteryzujących powierzchnię i jej przydatność w implantach. Odporność korozyjną zbadano w płynie Ringera. W wyniku przeprowadzonych badań stwierdzono, że na powierzchni piaskowanej nieużywanym proszkiem HA występuje większa liczba trwale umocowanych w niej cząstek HA, w porównaniu do powierzchni piaskowanej proszkiem używanym. Powierzchnia taka charakteryzuje się korzystniejszymi parametrami geometrycznymi przy niewielkim spadku odporności korozyjnej, w porównaniu do niepiaskowanej powierzchni Ti 99,6%. Implant piaskowany nieużywanym proszkiem HA, w którym proszki HA są wbite w powierzchnię, posiada potencjalnie lepszą powierzchnię do zajścia procesów osteointegracji i trwałego połączenia z tkanką kostną.
In this work we describe surface modification process of titanium, which is used in hard tissue implant applications. Titanium, although has excellent and useful properties, in the implant applications requires preparation a respective surface morphology. The aim of this work was to compare Ti 99.6% surfaces, used in implant applications, after HA/TCP (HA - hydroxyapatite, TCP - tricalcium phosphate) powder sandblasting. The aim of sandblasting is to increase the surface roughness, together with changing its chemical composition. So, after the treatment the sandblasted surface should enhance cells growth and proliferation and should be more biocompatible, respective for medical applications. For the sandblasting of the polished Ti surfaces we have used one fresh/new hydroxyapatite powder (first time used) and the second one used before in the implant production (after 300 sandblasting series of dental implants). The morphology and geometrical properties of surfa¬ce were investigated using SEM and optical profiler, respectively. Taking into account surface topography and usefulness in implants, the 11 2D/3D surface geometrical and hybrid parameters were determined. The corrosion potentiodynamic tests were done in Ringer solution. We have found that in the surface, sandblasted with fresh HA particles, were embedded more HA inclusions, and the surface is very rough in comparison to surface sandblasted with old HA particles. The corrosion resistance was slightly worse for sandblasted surfaces in comparison to mechanically polished one. Implants sandblasted with using of fresh HA (with embedded and strongly bonded with titanium HA particles) give potentially better surface for osseointegration process and stable bonding with the bone tissue.
Źródło:
Engineering of Biomaterials; 2013, 16, 119; 33-39
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Sandblasting and Sol Gel Techniques for the Preparation of a Metal Surface and Their Effects on the Durability of Epoxy-Bonded Joints
Autorzy:
Sałaciński, M.
Zabłocka, M.
Synaszko, P.
Powiązania:
https://bibliotekanauki.pl/articles/97751.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
epoxy-bonded joints
composite structures
repair
sandblasting treatment
aerospace
Opis:
The epoxy-bonded joints are widely employed in aerospace in the Composite Patch Bonded Repair (CPBR) method used for repair metallic and composite structures. The properties of epoxy usually meet the mechanical and environmental requirements, but the durability of bonded joints depends also on the surface preparation. The most common techniques used for the surface preparation are Forest Product Laboratory’s (FPL) technique and Phosphoric Acid Anodizing (PAA). Both methods ensure very good adhesion but they have some disadvantages. They require the application of toxic and aggressive acids, dangerous for the operator. Also, the use of acids for cleaning the surfaces can cause corrosion. The sandblasting treatment of metal surfaces ensures quite good adhesion. This technique requires neither specialist equipment nor the use of toxic substances. Recommended by the Royal Australian Air Force (RAAF) the technique is also used by the Air Force Institute of Technology. Sol Gel is a new product developed for the treatment of metal surfaces before bonding. It is not hazardous for the operator and it does not cause corrosion due to its specific chemical composition. The article describes the behavior of bonded joints between two metal surfaces prepared using sandblasting and Sol Gel. The investigations were carried out in various environment conditions according to the ASTM Standards.
Źródło:
Fatigue of Aircraft Structures; 2012, 4; 94-99
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution
Autorzy:
Burnat, B.
Walkowiak-Przybyło, M.
Błaszczyk, T.
Klimek, L.
Powiązania:
https://bibliotekanauki.pl/articles/306724.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
corrosion
PBS solution
polishing
sandblasting
titanium alloys
korozja
stop tytanu
piaskowanie
Opis:
In this work, we performed comparative studies of the effect of surface preparation of Ti6Al4V and Ti6Al7Nb biomedical alloys and the influence of endothelial cells on their corrosion behaviour in PBS (Phosphate Buffered Saline). Two different methods of surface modification were applied – polishing and sandblasting. The polished Ti6Al7Nb alloy was found to have the best resistance against general corrosion in PBS. It was characterized by the lowest corrosion rate, the widest passive range and the lowest reactivity. Both alloys prepared by sandblasting exhibited worse corrosion properties in comparison to the polished ones. This can be associated with a greater development of their surface and the presence of Al2O3 grains which caused an increase of corrosion potential but might also influence the weakening of the passive layer. Results of potentiodynamic anodic polarization indicated that more resistant to pitting corrosion was Ti6Al7Nb alloy regardless of the method of surface preparation. In those cases, anodic polarization caused only an increase of passive layer, while in the case of sandblasted Ti6Al4V alloy it caused a pitting corrosion. The results obtained allowed us to conclude that the niobium-titanium alloys had higher corrosion resistance than titanium alloys with vanadium. Moreover, it was stated that endothelial cells improved the corrosion resistance of all the titanium alloys examined.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 87-94
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strength of Epoxy-Bonded Aluminium Alloy Joints After Sandblasting
Autorzy:
Rudawska, Anna
Wahab, Magd Abdel
Müller, Miroslav
Powiązania:
https://bibliotekanauki.pl/articles/2180222.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sandblasting
aluminium alloy
epoxy adhesive
adhesive joints strength
surface roughness
statistical analysis
Opis:
The purpose of this article is to investigate the effect of sandblasting surface treatment, before the bonding process, on the strength of the adhesive joints of the three types of aluminium alloy sheets. Three values of pressure were used during the sandblasting process, i.e. 0.41 MPa, 0.51 MPa and 0.56 MPa. After mechanical treatment, the samples of aluminium alloys sheets were degreased three times with acetone by immersion. The elements were bonded with single-lap joints using two components epoxy adhesive. After the curing process, the shear strength tests of the aluminium alloy adhesive joints were conducted, according to the DIN EN 1465 standard. The surface topography of all samples was measured, and the most important surface roughness parameter and its waviness were determined. Based on the experimental results, it was noticed that, among others, while using the same pressure value during sandblasting of different aluminium alloys, the roughness parameters Ra and Rz of the obtained surfaces differed depending on the type of alloy. It is also to notice that more than two times strength of the joints was obtained by those made of the aluminium alloy sheet, which was subjected to heat treatment.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 2; 262--279
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stopnia proliferacji komórek osteoblastopodobnych w kontakcie z powierzchniami stopu tytanu po piaskowaniu do różnego stopnia chropowatości
Evaluation of proliferation rate of osteoblast-like cells in contact with titanium alloy surfaces sandblasted to different roughness level
Autorzy:
Bociąga, D.
Olejnik, A.
Jastrzębski, K.
Sobczyk-Guzenda, A.
Paradowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/284193.pdf
Data publikacji:
2016
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
piaskowanie
osteoblasty
Ti-6Al-4V
Ti-6Al-7Nb
obróbka powierzchniowa
sandblasting
osteoblasts
surface treatment
Opis:
Tytan i jego stopy są jednymi z najpopularniejszych biomateriałów metalicznych stosowanych w dzisiejszej implantologii. Mimo licznych zalet tych materiałów, wykonane z nich wszczepy często poddaje się dodatkowej obróbce powierzchni, której celem jest polepszenie integracji implantu z otaczającymi go tkankami. Spośród wielu dostępnych technik, jedną z najczęściej wykorzystywanych komercyjnie jest stosunkowo tania i szybka metoda piaskowania, polegająca na wystawianiu danego przedmiotu na kontakt ze strumieniem przyspieszonych cząstek materiału ściernego. Celem tej pracy była analiza wpływu piaskowania ścierniwem o różnej średnicy ziaren na właściwości obrabianej powierzchni elementów na bazie dwóch popularnych stopów tytanu: Ti-6Al-4V i Ti-6Al-7Nb. W celu scharakteryzowania uzyskanych powierzchni przeprowadzono badania ich topografii, składu chemicznego, chropowatości i zwilżalności. Ponadto, aby sprawdzić potencjalną reakcję organizmu na obecność obrobionych w ten sposób elementów dokonano oceny stopnia proliferacji ludzkich komórek kościotwórczych hodowanych w bezpośrednim kontakcie z przygotowanymi powierzchniami. Otrzymane wyniki wykazały wyraźną zależność pomiędzy stopniem chropowatości i składem chemicznym piaskowanych elementów, a zastosowanym do obróbki rodzajem medium ściernego. Badanie zachowania komórek będących w kontakcie z modyfikowanymi próbkami wykazało obniżoną skłonność osteoblastów do przylegania i namnażania na najbardziej chropowatych powierzchniach.
Titanium and its alloys are very popular metallic biomaterials used for medical implants production. Despite numerous advantages of the bulk material, such implants are very often subjected to additional surface treatment in order to improve their integration within the body tissues. Besides many other available techniques, one of the most frequently used in the commercial sector is a fast and economically profitable process of abrasive blasting. It is a method in which a stream of accelerated particles collides with the implant surface what causes changes in the material properties. The following paper presents differences resulting from sandblasting of Ti-6Al-4V and Ti-6Al-7Nb specimens with blasting particles varying in size. In order to characterize the outcome of such the treatment, investigations of surface topography, chemical composition, roughness, and wettability were conducted. Finally, the behaviour of the osteoblast- -like cells adhered to the sandblasted Ti-6Al-4V and Ti-6Al-7Nb surfaces was assessed in order to evaluate potential body response towards the aforementioned materials. The results suggest a strong correlation between surface roughness, its chemistry and the type of blasting medium applied. Evaluation of the cell culture revealed a rapid decrease in cell proliferation rate onto the roughest surfaces.
Źródło:
Engineering of Biomaterials; 2016, 19, 134; 8-17
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efekty utleniania tytanu po różnych metodach modyfikacji powierzchni
Titanium oxidation effects after various surface modification methods
Autorzy:
Jasiński, J.
Lubas, M.
Wieczorek, P.
Powiązania:
https://bibliotekanauki.pl/articles/286026.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
obróbka powierzchniowa (szlifowanie i polerowanie)
utlenianie tytanu
złoże fluidalne
chropowatość powierzchni
surface treatment (grinding and sandblasting)
titanium oxidation
fluidized bed
surface roughness
Opis:
W pracy przedstawiono analizę topografii powierzchni tytanu Grade 2 po obróbce mechanicznej (szlifowanie i piaskowanie) oraz wpływ aktywacji powierzchni na właściwości warstwy po procesie utleniania w złożu w temperaturze 610°C i czasie 6, 8 i 12 godzin. Do badań topografii powierzchni oraz analizy adhezji zastosowano metodę AFM i scratch test, natomiast strukturę i zmiany składu fazowego badano z zastosowaniem metody SEM-EDS i XRD. Badania topografii powierzchni tytanu Grade 2 przed procesem utleniania potwierdziły, że przeprowadzona aktywacja powierzchni z wykorzystaniem medium piaskującego w postaci Al2O3 korzystnie wpływa na zwiększenie chropowatości oraz poprawę stanu powierzchni tytanu po procesie utleniania szczególnie w czasie 8 godzin. Stwierdzono również, że zastosowanie złoża fluidalnego do procesów utleniania tytanu pozwala na otrzymanie jednorodnych powłok tlenkowych o dobrej adhezji z podłożem, a tym samym poprawę właściwości powierzchni tytanu w aspekcie zastosowań biomedycznych.
The paper presents an analysis of titanium grade 2 surface topography after surface treatment (grinding and sandblasting) and the influence of surface activating on the properties of the surface layer after the oxidation process in a Al2O3 fluidized bed, at 610°C and for 6, 8 and 12 hours. AFM and scratch test methods were used for surface topography and layer adhesion analysis, while SEM-EDX and XRD methods were used to examine the microstructure and changes in phase composition. Studies of Grade 2 titanium surface topography before oxidation confirmed that the surface activation carried out using the Al2O3 blasting medium increases the roughness and improves the state of titanium surface after oxidation, especially after 8 h. The results also showed that using of a fluidized bed for titanium oxidation allows to obtain uniform oxide layers for biomedical applications.
Źródło:
Engineering of Biomaterials; 2013, 16, 120; 41-47
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne zastosowanie metodyki FAA do przyklejania próbek kompozytowych, do testów kwalifikacji materiału
Practical application of FAA methodology of composite specimens used to material tests qualifications
Autorzy:
Jaśkiewicz, R.
Stepniowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/213356.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
preparatyka płyt kompozytowych
kompozyty polimerowe
dokument FAA
piaskowanie kompozytów
szlifowanie kompozytów
composities samples preparation
polimer composities
FAA document
composities sandblasting
composities grinding
Opis:
Artykuł ma na celu sprawdzenie praktycznego zastosowania metodyki FAA (Federalna Administracja Lotnictwa - Federal Aviation Administration) do przygotowania próbek kompozytowych, do testów kwalifikacji materiału. Dokonano przeglądu literaturowego na potrzeby weryfikacji postanowień FAA w aspekcie testów kwalifikacji materiału. Przedmiotem badanym była plyta kompozytowa wykonana z włókna węglowego, o wymiarach 30x56 cm oraz średniej grubości 3,187 mm. W artykule porównano stosowane dwie metody przygotowania powierzchni płyt kompozytowych do badań: piaskowanie i szlifowanie. W trakcie piaskowania zmiennymi parametrami był czas (30s, 40s i 50s), ciśnienie (3 bar i 3,5 bar) i rodzaj ścierniwa (mikrokulki szklane oraz mikrokulki ceramiczne). Pozwoliło to na weryflkację wpływu różnych wartości parametrów na jakość powierzchni piaskowanej, a takż porównać ją z obszarami szlifowanymi.
Test practical application of FAA (Federal Aviation Administration) methodology for composite samples preparation for material qualification testing was written in this article. Review of the literature was made to verify the FAA provisions in aspect of material qualification testing. Research has been done with a composite panel (30x56 cm, average thickness 3.187 mm). The article compares two methods used for composite panel surface preparation: sandblasting and grinding. During sandblasting tests, variable parameters was: time (30 s, 40 s and 50 s), pressure (3 bar and 3.5 bar), and the type of abrasive (glass microspheres and ceramic microspheres). This allowed to verify effects of various parameters on the quality of sandblasted surface, and to compare it with grinded areas.
Źródło:
Prace Instytutu Lotnictwa; 2016, 3 (244); 72-76
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies