Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "rezonans magnetyczny" wg kryterium: Temat


Tytuł:
A second-order TV-based coupling model and an ADMM algorithm for MR image reconstruction
Autorzy:
Zhou, Bo
Yang, Yu-Fei
Hu, Bo-Xia
Powiązania:
https://bibliotekanauki.pl/articles/330846.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
MRI reconstruction
LLT model
LOT model
coupling model
ADMM algorithm
split Bregman
wavelet transform
rezonans magnetyczny
metoda Bregmana
transformata falkowa
Opis:
Motivated by ideas from two-step models and combining second-order TV regularization in the LLT model, we propose a coupling model for MR image reconstruction. By applying the variables splitting technique, the split Bregman iterative scheme, and the alternating minimization method twice, we can divide the proposed model into several subproblems only related to second-order PDEs so as to avoid solving a fourth-order PDE. The solution of every subproblem is based on generalized shrinkage formulas, the shrink operator or the diagonalization technique of the Fourier transform, and hence can be obtained very easily. By means of the Barzilai–Borwein step size selection scheme, an ADMM type algorithm is proposed to solve the equations underlying the proposed model. The results of numerical implementation demonstrate the feasibility and effectiveness of the proposed model and algorithm.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2020, 30, 1; 113-122
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy można zmierzyć myśli, czyli podstawy funkcjonalnego rezonansu magnetycznego
Are thoughts measurable - fundamentals of magnetic resonance imaging
Autorzy:
Zaremba, K.
Powiązania:
https://bibliotekanauki.pl/articles/151974.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
jądrowy rezonans magnetyczny
funkcjonalny rezonans magnetyczny
obrazowanie czynnościowe
obrazowanie medyczne
nuclear magnetic resonance (NMR)
functional magnetic resonance imaging
medical imaging
Opis:
W artykule przedstawiono podstawy fizyczne techniki magnetycznego rezonansu jądrowego (MRI), a także jej zastosowania w badaniach czynnościowych mózgu. Przedstawiono przykładowe zastosowania w diagnostyce medycznej oraz w badaniach podstawowych dotyczących funkcji mózgu.
The paper presents fundamentals of magnetic resonance imaging (MRI) technique, as well as its applications in functional imaging of a brain. Example applications are given, both in the medical diagnostics and fundamental research regarding the brain functions.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 6, 6; 334-335
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena nasycenia przestrzeni porowej piaskowców mioceńskich metodą magnetycznego rezonansu jądrowego
Assessment of the Miocene sandstones porous space saturation with Nuclear Magnetic Resonance Method
Autorzy:
Zalewska, J.
Klaja, J.
Cebulski, D.
Powiązania:
https://bibliotekanauki.pl/articles/183678.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
magnetyczny rezonans jądrowy (NMR)
MRJ
stała relaksacji poprzecznej T2
nuclear magnetic resonance (NMR)
NMR
T2 relaxation constant
Opis:
Nuclear Magnetic Resonance (NMR) data provide affluence of information about porous space saturation distribution, porosity itself and permeability, thanks to close relationship between pore sizes and transverse relaxations time distribution. Having known values of these parameters, and especially irreducible water saturation of rocks it is possible to determine reservoir properties of rocks much more precisely. The study presents results of laboratory tests carried out with use of NMR method on the Miocene sandstones representing Dzików gas field. The samples featured extensive variability of reservoir properties within profile of individual boreholes. The highest number of rocks having good reservoir and filtration properties, originated from Dzików-12 borehole, and they were characterised by low irreducible water saturation coefficient and high free water volume.
Źródło:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie; 2009, 35, 2/1; 607-615
0138-0974
Pojawia się w:
Geologia / Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estymacja map ukrwienia i napowietrzenia płuc za pomocą wąskopasmowej filtracji dwuwymiarowych sygnałów rezonansu magnetycznego
Estimation of lung perfusion and ventilation images by narrowband filtering of 2D MR signals
Autorzy:
Wujcicki, A.
Materka, A.
Powiązania:
https://bibliotekanauki.pl/articles/261433.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
perfuzja
wentylacja płuc
rezonans magnetyczny
perfusion
lung ventilation
magnetic resonance
Opis:
W pracy przedstawiono wyniki badań dotyczących estymacji map ukrwienia i napowietrzenia płuc człowieka na podstawie analizy sekwencji obrazów 2D rezonansu magnetycznego (RM). Wyniki omówiono na przykładzie obrazów RM płuc w pozycji koronalnej. Opracowano algorytm wyznaczania transmitancji wąskopasmowych filtrów użytych do rozdzielenia informacji o ukrwieniu i napowietrzeniu płuc, w oparciu o analizę sekwencji obrazów RM. Zaproponowano ilościową miarę jakości estymowanych map ukrwienia i napowietrzenia.
The paper presents results of research on the estimation of lungs perfusion and ventilation by analysis of 2D magnetic resonance (MR) lung images sequence. The results are presented for lung images in coronal view. An algorithm based on an analysis of lung images sequence, for determining narrow band filters used to separate the perfusion and ventilation information, was elaborated. In this work, a quantitative measure of the quality of the estimated perfusion and ventilation was proposed.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2015, 21, 3; 158-164
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podstawy działania komputera kwantowego wykorzystującego zjawisko jądrowego rezonansu magnetycznego
Quantum computer implemented with use of nuclear magnetic resonance phenomenon - basics of working
Autorzy:
Wiśniewska, J.
Powiązania:
https://bibliotekanauki.pl/articles/305899.pdf
Data publikacji:
2008
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
komputer kwantowy
bramki kwantowe
jądrowy rezonans magnetyczny
quantum computer
quantum gates
nuclear magnetic resonance phenomenon
Opis:
Referat zawiera informacje dotyczące teoretycznych podstaw budowy komputera kwantowego. W ramach implementacji takiego urządzenia proponowane są różne metody. Tu przybliżony został pomysł wykorzystania zjawiska jądrowego rezonansu magnetycznego. Następnie zostały przedstawione macierzowe postacie operatorów unitarnych, które odwzorowują podstawowe operacje logiczne, jakie będzie w stanie wykonać komputer kwantowy. Referat nie zawiera oryginalnego dorobku naukowego autorki, lecz został przygotowany jako materiał szkoleniowy na XXII Sympozjum Koła Zainteresowań Cybernetycznych Wojskowej Akademii Technicznej na podstawie [5].
Paper contains information about theory of constructing quantum computer. There are a few different propositions of this kind device's implementation and, in this article, method based on nuclear magnetic resonance phenomenon were characterized. The paper contains also matrix forms of unitary operators, which describe basic logical operations for quantum computer. This thesis doesn't include author's genuine researches' results. The article were prepared as a training material for XXII Meeting of Cybernetic Interests' Circle.
Źródło:
Biuletyn Instytutu Systemów Informatycznych; 2008, 1; 69-74
1508-4183
Pojawia się w:
Biuletyn Instytutu Systemów Informatycznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Philips Ingenia Ambition 1.5T – zapomnij o helu
Autorzy:
Winiarczyk, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2146803.pdf
Data publikacji:
2021
Wydawca:
Indygo Zahir Media
Tematy:
rezonans magnetyczny
magnes typu BlueSeal
diagnostyka medyczna
Opis:
Philips Ingenia Ambition 1.5T wciąż jest jedynym silnopolowym rezonansem magnetycznym, uwalniającym użytkownika od trosk o dostępność i ceny helu. Jego światowa premiera miała miejsce niespełna trzy lata temu. Czego przez ten czas nauczyliśmy się o nowym magnesie BlueSeal z obsługą bezhelową?
Źródło:
Inżynier i Fizyk Medyczny; 2021, 10, 1; 41--43
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rezonans magnetyczny i spektroskopowa ocena metabolitow tkanki mozgowej w przebiegu kryptokokozy OUN
Autorzy:
Wiercinska-Drapalo, A
Tarasow, E.
Powiązania:
https://bibliotekanauki.pl/articles/837005.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
rezonans magnetyczny
kryptokokoza
czynniki chorobotworcze
choroby pasozytnicze
spektroskopia magnetycznego rezonansu jadrowego
parazytologia
grzyby drozdzoidalne
metabolity
tkanka mozgowa
tkanka nerwowa
Cryptococcus neoformans
Opis:
Cryptococcus neoformans is the causative agent of cryptococcosis and cryptococcal meningitis, which are serious pathological conditions affecting up to 10% of patients with AIDS. In this paper we present results magnetic resonance imaging and spectroscopic metabolites (1H MR) in brain cryptococcosis. In 1HMR spectroscopy we tind decreased metabolic ratios to nonsaturated water (H2O) signal N-acetylaspartate (NA/H20, creatine (Cr/H20), choline (Cho/H20). We show increased mioinositol to H2O ratio. Spectroscopy results suggest about massive neuronal injury and accompanying gliosis in brain cryptococcosis.
Źródło:
Annals of Parasitology; 2001, 47, 3; 535-541
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rezonans magnetyczny i spektroskopowa ocena metabolitów tkanki mózgowej w przebiegu kryptokokozy OUN
MAGNETIC RESONANCE IMAGING AND SPECTROSCOPIC METABOLITES ASSESSMENT IN BRAIN CRYPTOCOCCOSIS
Autorzy:
Wiercińska-Drapało, A.
Tarasow, E.
Powiązania:
https://bibliotekanauki.pl/articles/2148076.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
rezonans magnetyczny
kryptokokoza
czynniki chorobotworcze
choroby pasozytnicze
spektroskopia magnetycznego rezonansu jadrowego
parazytologia
grzyby drozdzoidalne
metabolity
tkanka mozgowa
tkanka nerwowa
Cryptococcus neoformans
Opis:
Cryptococcus neoformans is the causative agent of cryptococcosis and cryptococcal meningitis, which are serious pathological conditions affecting up to 10% of patients with AIDS. In this paper we present results magnetic resonance imaging and spectroscopic metabolites (1H MR) in brain cryptococcosis. In 1HMR spectroscopy we tind decreased metabolic ratios to nonsaturated water (H2O) signal N-acetylaspartate (NA/H20, creatine (Cr/H20), choline (Cho/H20). We show increased mioinositol to H2O ratio. Spectroscopy results suggest about massive neuronal injury and accompanying gliosis in brain cryptococcosis.
Źródło:
Wiadomości Parazytologiczne; 2001, 47, 3; 535-541
0043-5163
Pojawia się w:
Wiadomości Parazytologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pacjent z CADASIL – wyzwanie diagnostyczne
Patient with CADASIL – a diagnostic challenge
Autorzy:
Węgrzynek, Julia
Tomaszewska, Agnieszka
Wawrzkiewicz-Witkowska, Angelika
Powiązania:
https://bibliotekanauki.pl/articles/11542715.pdf
Data publikacji:
2023-09-13
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
CADASIL
NOTCH3
stwardnienie rozsiane
ostre rozsiane zapalenie mózgu
udar
leukoencefalopatia
arteriopatia
rezonans magnetyczny
sclerosis multiplex
acute disseminated encephalomyelitis
stroke
leukoencephalopathy
arteriopathy
magnetic resonance imaging
Opis:
WSTĘP: Mózgowa autosomalnie dominująca arteriopatia z podkorowymi zawałami i leukoencefalopatią (cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy – CADASIL) jest uwarunkowaną genetycznie i dziedziczoną w sposób autosomalnie dominujący chorobą małych naczyń. Jej wystąpienie wiąże się z mutacją w genie NOTCH3. Pierwsze objawy kliniczne pojawiają się w 3. lub 4. dekadzie życia, a poprzedzone są zmianami leukodegeneracyjnymi, które najlepiej uwidacznia rezonans magnetyczny (RM). Częstość występowania choroby określa się na 2–5 osób na 100 000. Obraz kliniczny pacjentów z CADASIL jest heterogenny. Najczęstsze objawy to nawracające udary, przemijające ataki niedokrwienne, przyczyniające się do deficytów poznawczych, oraz migreny z aurą. Pomimo coraz powszechniejszej znajomości CADASIL choroba ta wciąż stanowi wyzwanie diagnostyczne. OPIS PRZYPADKU: 60-letni mężczyzna został skierowany do poradni genetycznej z podejrzeniem CADASIL. Pierwsze symptomy choroby pojawiły się u niego prawdopodobnie w wieku 40 lat (1998 r.) w postaci zmian radiologicznych. Rezonans magnetyczny ujawnił wówczas okołokomorowe obszary hiperintensywnego sygnału w sekwencji T2-zależnej. W kolejnych latach na podstawie wykonywanych RM pacjenta diagnozowano w kierunku stwardnienia rozsianego oraz ostrego rozsianego zapalenia mózgu. W wieku 58 lat pacjent został przyjęty na oddział neurologii po napadzie padaczkowym. Rezonans magnetyczny wykazał okołokomorowe i nadnamiotowe zmiany istoty białej oraz lakuny poudarowe. Wysunięto podejrzenie, że przyczyną jest CADASIL. W poradni genetycznej diagnozę potwierdzono badaniami genetycznymi. Wykryto wariant patogenny NM_000435: c.268C > T (p.Arg90Cys). WNIOSKI: W diagnostyce różnicowej CADASIL należy brać pod uwagę choroby demielinizacyjne. Postawienie właściwej diagnozy ułatwia dokładny wywiad rodzinny oraz zestawienie go z wynikami badań obrazowych.
INTRODUCTION: Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a genetically determined and hereditary cerebral small vessel disease caused by mutations in the NOTCH3 gene. The onset is in the 3rd and 4th decade of life and is preceded by leukodegenerative changes, which are best visualized by magnetic resonance imaging (MRI). The prevalence of CADASIL is estimated at 2 to 5 people in 100,000. The clinical picture is heterogenous. The main clinical features include recurrent subcortical ischemic events, mood disturbances, progressive cognitive impairment and migraines with aura. Despite the growing recognition of CADASIL, this disease is still a diagnostic challenge. CASE REPORT: A 60-year-old man was referred to the genetic clinic for suspected CADASIL. The initial clinical symptoms probably occurred at the age of 40 in the form of radiological changes. The MRI performed then revealed periventricular zones of a T2 hyperintense signal. Based on follow-up MRIs, the patient was diagnosed with multiple sclerosis or acute disseminated encephalomyelitis. At the age of 58, following a seizure attack he was admitted to hospital and a performed MRI that revealed periventricular white matter degeneration and lacunes. CADASIL was suspected to be the cause. The diagnosis was confirmed by molecular testing. A pathogenic variant NM_000435: c.268C > T (p.Arg90Cys) was detected. CONCLUSIONS: It is relevant to pay attention to radiological findings and family history in the diagnostic pro-cess of a patient presenting symptoms which may suggest CADASIL to differentiate this genetic condition from demyelinating diseases.
Źródło:
Annales Academiae Medicae Silesiensis; 2023, 77, 1; 151-157
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zanik wieloukładowy typu C (MSA-C) – aspekty kliniczne i radiologiczne, opis przypadku
Clinical and radiological features of multiple system atrophy type C. Case report
Autorzy:
Węglewski, Arkadiusz
Juryńczyk, Jacek
Ślusarek, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/1061185.pdf
Data publikacji:
2006
Wydawca:
Medical Communications
Tematy:
autonomic failure
cerebellar atrophy
magnetic resonance
multiple system atrophy
orthostatic hypotension
rezonans magnetyczny
zanik móżdżku
zanik wieloukładowy
niewydolność autonomiczna
hipotonia ortostatyczna
Opis:
Multiple system atrophy (MSA) is a relatively rare degenerative disease of the central nervous system. The prevalence of MSA is about 2-4/100,000. The disease is included to synucleinopathies. The most characteristic neuropathological findings in MSA is argyrophilic glial cytoplasmatic inclusions in oligodendroglia which is composed of α-synuclein and ubiquitin. At present two main forms of the MSA are known: MSA-P and MSA-C. Symptoms of parkinsonism with rigidity and bradykinesia are more typical in MSA-P. Cerebellar signs are more characteristic for MSA-C. Severe autonomic failure, initially or during further clinical course stwierin MSA-P and MSA-C is present in most patients. The main symptoms of autonomic failure are orthostatic hypotension, urinary and less commonly fecal incontinence, impotence. In 1998 consensus on the diagnosis of MSA was established. The authors described a case of 61-year-old woman with 3 years of symptoms of cerebellar dysfunction followed by Parkinson’s syndrome and autonomic failure. MRI of the brain revealed severe atrophy of the cerebellum and brain stem, and “hot cross bun sign” in pons. Tilt-test confirmed orthostatic hypotension. Treatment with L-dopa and midodrin was moderately effective. The authors described problems of diagnostics, especially role of MRI, and actual problems of epidemiology, pathogenesis and treatment of MSA.
Zanik wieloukładowy (MSA) jest rzadką chorobą zwyrodnieniową ośrodkowego układu nerwowego. Występuje z częstością ocenianą na 2-4/100.000 i zaliczany jest do synukleinopatii. Najbardziej charakterystyczną cechę neuropatologiczną stanowi obecność srebrnochłonnych wtrętów cytoplazmatycznych w komórkach oligodendrogleju, zawierających α-synukleinę i ubikwitynę. Obecnie wyróżnia się dwie główne formy MSA: MSA-P i MSA-C. W MSA-P dominują objawy parkinsonizmu, głównie sztywność, spowolnienie, a w MSA-C – objawy uszkodzenia móżdżku. W obu formach typowe są nasilone objawy dysfunkcji układu autonomicznego, głównie hipotonia ortostatyczna, zaburzenia zwieraczy oraz impotencja. W 1998 roku ustalono kryteria diagnostyczne MSA. Autorzy przedstawiają przypadek 61-letniej chorej z mniej więcej 3-letnim wywiadem zespołu móżdżkowego, do którego dołączyły się następnie objawy autonomiczne i parkinsonowskie. Badanie MR głowy ujawniło charakterystyczne dla formy MSA-C dużego stopnia zanik móżdżku, pnia mózgu oraz objaw „krzyża” w moście. Test pionizacyjny wskazał na ciężką hipotonię ortostatyczną. Leczenie L-dopą w umiarkowany sposób zmniejszyło nasilenie zespołu parkinsowskiego, a midodrinem – hipotonii ortostatycznej. Autorzy omawiają problemy diagnostyki MSA, ze szczególnym uwzględnieniem roli badania MR, oraz przedstawiają aktualny stan wiedzy na temat patogenezy, epidemiologii i terapii MSA.
Źródło:
Aktualności Neurologiczne; 2006, 6, 1; 48-53
1641-9227
2451-0696
Pojawia się w:
Aktualności Neurologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie obrazowania techniką rezonansu magnetycznego w diagnostyce niepłodności kobiecej : rozprawa na stopień doktora habilitowanego
Autorzy:
Twarkowski, Paweł.
Data publikacji:
1999
Wydawca:
Warszawa : Centralny Szpital Kliniczny Wojskowej Akademii Medycznej im. gen. dyw. Bolesława Szareckiego
Tematy:
Narząd płciowy żeński choroby diagnostyka
Niepłodność diagnostyka
Rezonans magnetyczny jądrowy stosowanie medycyna
Opis:
Rozprawa habilitacyjna.
Bibliogr. --- Sum.
Dostawca treści:
Bibliografia CBW
Książka
Tytuł:
Ocena przydatności średniopolowych systemów MR w obrazowaniu hodowli komórkowych
Assessment of the usefulness of medium-field MR systems in imaging of cell cultures
Autorzy:
Truszkiewicz, Adrian
Bartusik-Aebisher, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/985832.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
rezonans magnetyczny
mikroskopia MRI
hodowle komórkowe
magnetic resonance imaging
MRI microscopy
cell cultures
Opis:
W niniejszym artykule autorzy podjęli próbę oceny przydatności systemów rezonansu magnetycznego o sile 1,5 Tesla do obrazowania małych struktur, jakimi są hodowle komórkowe. Zakres obrazowania, jaki stał się przedmiotem badań, wkracza w obszar będący domeną mikroskopii rezonansu magnetycznego (MRM). W dzisiejszej dobie badania te wykonywane są przy użyciu systemów wysokopolowych zapewniających dużo większe rozdzielczości przestrzenne. Celem pracy było określenie warunków, jak również parametrów skanowania pozwalających na obrazowanie małych obiektów przy wykorzystaniu systemu OPTIMA MR360 produkcji GE Healthcare. W wyniku prac koniecznym stało się opracowanie dodatkowej cewki solenoidalnej, której to zarówno wymiary, kształt, jak i konstrukcja zapewniły optymalną jakość obrazowania możliwą do uzyskania w oparciu o w/w system MR. Artykuł ten jest pierwszym z serii prac ukazujących badania hodowli komórkowych z użyciem rezonansu magnetycznego w Uniwersytecie Rzeszowskim.
In this article, the authors attempt to assess the usefulness of 1,5 Tesla magnetic resonance imaging systems for imaging of small structures such as cell cultures. The scope of imaging that has become the subject of research enters the area that is the domain of magnetic resonance microscopy (MRM). Nowadays, these tests are performed using high-field systems providing much higher spatial resolutions. The purpose of the work was to determine the conditions as well as scanning parameters that allow imaging of small objects using the OPTIMA MR360 production system. GE Healthcare. As a result of the work, it became necessary to develop an additional solenoid coil, which both dimensions, shape and design ensured optimal imaging quality possible based on the above MR system. This article is the first in a series of works showing the study of cell cultures using magnetic resonance imaging at the University of Rzeszów.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 1; 37-40
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspektywy badań mózgowia z wykorzystaniem MRI
Prospects for brain research using MRI
Autorzy:
Truszkiewicz, Adrian
Dynarowicz, Klaudia
Bartusik-Aebisher, Dorota
Cholewa, Marian
Powiązania:
https://bibliotekanauki.pl/articles/985830.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
rezonans magnetyczny
sekwencje
badanie OUN
magnetic resonance imaging
sequences
CNS examination
Opis:
Rezonans magnetyczny (MRI) zmodyfikował praktykę radiologii w dziedzinie badań mózgowia. Technika ta opiera się na bezpiecznej interakcji pomiędzy falami radiowymi o określonej częstotliwości i jądrami wodoru w ciele człowieka lub w innym badanym obiekcie. Szczególny postęp zaobserwowano w badaniach ilościowych i jakościowych metabolitów, które z definicji nie są zaburzeniami ośrodkowego układu nerwowego i które nie są spowodowane nieprawidłowościami strukturalnymi, dlatego występują endogennie w niewielkich ilościach. W pracy przedstawiono pogląd na obecne wykorzystanie MRI w badaniach mózgowia.
Magnetic resonance imaging (MRI) has modified radiology in the field of brain research. This technique is based on the safe interaction between radio waves of a certain frequency and hydrogen nuclei in the human body or other object being tested. Particular progress has been observed in the quantitative and qualitative studies of metabolites which by definition are not disorders of the central nervous system, and which are not caused by structural abnormalities and therefore occur in small amounts enodogenously. The paper presents the view on the current use of MRI in brain research.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 1; 21-22
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Składowe ośrodka jako czynnik zakłócający wynik pomiaru czasu relaksacji T1
The influence of medium components as a factor disturbing the result of the measurement of the relaxation time T1
Autorzy:
Truszkiewicz, Adrian
Aebisher, David
Bartusik-Aebisher, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/2146785.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
rezonans magnetyczny
relaksacja podłużna
relaksacja poprzeczna
czas relaksacji
magnetic resonance imaging
longitudinal relaxation
lateral relaxation
relaxation times
Opis:
Niniejsza praca ukazuje jedno z wybranych źródeł błędów, jakie znacznie powiększają niepewność wyniku określania czasu T1. Autorzy skupili się na wpływie ośrodka, w którym znajduje się badany obszar, na wartość czasu relaksacji. Pokazano na przykładzie fantomu, jak może się zmieniać wartość mierzonego parametru w zależności od właściwości składowych ośrodka. Założeniem każdej tomografii pozwalającej na obrazowanie dowolnych obiektów ze skończoną rozdzielczością przestrzenną jest to, iż piksel na całej swej powierzchni ma jednakową gęstość czy też skład chemiczny. W znakomitej większości przypadków jest to daleko posunięte uproszczenie, które pominięte w czasie analizy może doprowadzić do bardzo poważnych błędów interpretacji wyników prowadzonej diagnostyki czy też bardziej ogólnie badań.
This paper shows one of the selected sources of errors that significantly increase the uncertainty of the result of determining the time T1. The authors focused on the influence of the center in which the studied area is located on the value of the relaxation time. It was shown on the example of a phantom how the value of the measured parameter can change depending on the properties of the medium components. The assumption of each tomography that allows imaging of any objects with finite spatial resolution is that the pixel has the same density or chemical composition on its entire surface. In the vast majority of cases, it is a far-reaching simplification which, omitted during the analysis, may lead to very serious errors in the interpretation of the results of the diagnostics or, more generally, tests.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 6; 391--395
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termometria rezonansu magnetycznego
Thermometry of magnetic resonance
Autorzy:
Truszkiewicz, Adrian
Bartusik-Aebisher, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/985931.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
czas relaksacji
pomiar temperatury
termometria
MRI
termoterapia
PFR
rezonans magnetyczny
magnetic resonance imaging
temperature measurement
thermometry
thermotherapy
Opis:
Odkryte w połowie XX wieku zjawisko rezonansu magnetycznego stanowi do dnia dzisiejszego potężne narzędzie w rękach badaczy. Znajduje zastosowanie zarówno w naukach biologicznych, jak i technicznych. Sztandarowym zastosowaniem metody obrazowania wykorzystującego zjawisko rezonansu magnetycznego jest medycyna. Ta w pełni nieinwazyjna metoda pozwala na badanie ludzkiego ciała w sposób dotąd niespotykany. Niniejsza praca prezentuje jeden z aspektów zastosowania tej metody, a mianowicie termometrię rezonansu magnetycznego (MRT). W pracy dokonano przeglądu metod pozwalających na monitorowanie temperatury metodą MRI. Pokazano źródła błędów, jak również wybrane metody ich redukcji. Cel pracy. Celem pracy jest przedstawienie metod pomiaru temperatury wnętrza ludzkiego ciała metodami MRI. Termometria MRI (MRT) to ważna funkcjonalność pozwalająca na nieinwazyjne mierzenie temperatury w miejscach o ograniczonym dostępie. Funkcjonalność ta jest nieodzowna w prowadzeniu niektórych rodzajów terapii nowotworów. Znajomość rozkładu temperatur nie tylko w punkcie, ale w całej objętości jest kluczowa do tego rodzaju zastosowań.
The phenomenon of magnetic resonance imaging discovered in the mid-20th century is a powerful tool to this day in the hands of researchers. It finds application in both sciences biological and technical. The main application field of the resonance phenomenon is medicine. The method is completely non-invasive and allows the examination of the human body in a manner so far unparalleled. This work presents one aspect of the application of this methods, called magnetic resonance imaging thermometry (MRIT). The paper reviews methods allowing for temperature monitoring. Error sources as well as selected methods of their reduction is presented. Objective of the work. The purpose of the work is to present methods for the measurements of internal body temperature by MRI . Thermometry MRI (MRIT) is an important field that allows non-invasive temperature measurement. This functionality is indispensable in driving certain types of cancer therapy. Knowledge of the temperature is crucial for this application.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 5; 385-389
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies