Tytuł:
Reverse osmosis as one-step wastewater treatment: a case study on groundwater pollution
Autorzy:
Ali, W.
Rehman, W. U.
Younas, M.
Ahmad, M. I.
Gul, S.
Powiązania:
https://bibliotekanauki.pl/articles/779416.pdf
Data publikacji:
2015
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
reverse osmosis (RO)
membrane separation
Total Dissolved Solids (TDS)
Total Coliform
E. Coli
Opis:
The present case study is focused on performance evaluation of a Reverse Osmosis (RO) membrane based pilot plant to treat the ground/surface drinking water sources polluted by flood, rivers and/or canals. The RO plant was designed, fabricated and then operated with polluted water. Two feed water samples having a TDS of 2.000 mg · L−1 and 10.000 mg · L−1 respectively, were taken and analyzed for physical, chemical and microbiological contaminants. The RO plant was run once through over a span of 100 hrs at an operating pressure of 15 bar. TDS rejections were found to be more than 94% while permeate flux was measured to be 25.82 L · m−2 · hr−1 to 40.55 L · m−2 · hr−1. Results show that RO plant has a potential to remove physical, chemical and microbiological contaminants like Total Coliform and E. Coli in one step.
Źródło:
Polish Journal of Chemical Technology; 2015, 17, 4; 42-48
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Ultrasonic Field on the Efficiency of Landfill Leachate Co-Treatment in Anaerobic Digestion - Reverse Osmosis System
Wpływ pola ultradźwiękowego na efektywność współoczyszczania odcieków w układzie zintegrowanym fermentacja beztlenowa - odwrócona osmoza
Autorzy:
Bohdziewicz, J.
Kwarciak-Kozłowska, A.
Kuglarz, M.
Powiązania:
https://bibliotekanauki.pl/articles/388373.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
odcieki ze składowisk odpadów komunalnych
fermentacja metanowa
reaktor membranowy (MBR)
odwrócona osmoza (RO)
pole ultradźwiękowe
landfill leachate
anaerobic digestion
membrane reactor (MBR)
reverse osmosis (RO)
ultrasonic field
Opis:
The results of a research project pertaining to the specification of the influence of the ultrasonic, US field on the efficiency of landfill leachate co-treatment in the process of anaerobic digestion associated with reverse osmosis were presented. The biological process - methane fermentation - was conducted in the bioreactor equipped with submerged membrane module (MBR reactor). The concentration of the anaerobic sludge granules was maintained at the fixed level of 10 g/m3. The samples both after and before ultrasonic disintegration underwent the digestion process. Hydraulic retention time was varied within the range of between l and 3 days, which allowed to increase the OLR (Organic Loding Rate) value from 1.3 kg COD/m3d to 4.0 kg COD/m3d. It was established that ultrasonic disintegration reduced the HRT value from 2 to 1.5 days, as compared with non-disintegrated samples. What is more, ultrasonic, US-facilitated samples exhibited a higher COD reduction as well as the overall biogas production, on average by 10 % and 11 %, respectively. Since the biologically treated effluent in both analysed modes (MBR and MBR+US) exhibited a high degree of contamination - which did not allow to release the effluent into the natural water - an attempt was made to post-treat it by means of a high-driven membrane process, ie reverse osmosis. The application of reverse osmosis enabled a high degree of pollutants reduction. However, the final volumetric permeate flux (in both cases, ie MBR and MBR +US) exhibited an excessive concentration of ammonia nitrogen, which did not allow to release the effluent into receiving water. It was suggested that further experiments should additionally be based on nitrogen ammonia removal processes, eg ammonia stripping.
Przedstawiono wyniki badań dotyczące określenia wpływu pola ultradźwiękowego (UD) na efektywność współoczyszczania odcieków ze ściekami syntetycznymi w procesie fermentacji metanowej skojarzonym z odwróconą osmozą. Oczyszczanie ścieków metodą biologiczną realizowano w beztlenowym bioreaktorze z zanurzonym modułem membranowym (MBR), w którym stężenie osadu granulowanego utrzymywano na poziomie 10 g/dm3. Czas zatrzymania w reaktorze zmieniano w zakresie wartości od 3 do l d, uzyskując dzięki temu wzrost obciążenia reaktora ładunkiem zanieczyszczeń od 1,3 do 4,0 kg ChZT/m3d. Stwierdzono, że kondycjonowanie odcieków w polu UD pozwoliło na skrócenie z 2 do 1,5 d hydraulicznego czasu zatrzymania mieszaniny współoczyszczanych ścieków w reaktorze MBR w porównaniu z procesem fermentacji prowadzonym dla odcieków nie poddawanych nadźwiękawianiu. Odnotowano również średnio o 10 % większy stopień usunięcia ChZT oczyszczonych ścieków dla każdego z przebadanych HRT i o 11 % większą objętość generowanego biogazu. Z uwagi na fakt, że ścieki po procesie beztlenowej biodegradacji w obu przebadanych układach (MBR i MBR+UD) nadal charakteryzowały się dużym ładunkiem zanieczyszczeń uniemożliwiającym ich bezpośrednie odprowadzenie do odbiornika naturalnego, podjęto próbę ich doczyszczania metodą odwróconej osmozy. Pomimo bardzo dużej retencji ładunku zanieczyszczeń, w otrzymanym permeacie stężenie azotu amonowego pozostało nadal na zbyt wysokim poziomie. W celu obniżenia pozostałego azotu amonowego poniżej wartości umożliwiającej odprowadzenie do odbiornika naturalnego zaproponowano, aby w kolejnych etapach badań włączyć do badanego układu proces odpędzania amoniaku.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 11; 1483-1490
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental versus theoretical study of reverse osmosis pilot scaling: The case of Algerian brackish water desalination
Eksperymentalne i teoretyczne badania odwróconej osmozy: Przykład odsalania słonawych wód Algierii
Autorzy:
Bouchareb, Abderrezak
Metaiche, Mehdi
Lounici, Hakim
Powiązania:
https://bibliotekanauki.pl/articles/292539.pdf
Data publikacji:
2019
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ions salts rejection
reverse osmosis (RO)
ROSA software
salt passage (B)
spiral wound membrane (SWM)
membrana spiralna
odwrócona osmoza
program ROSA
stężenie soli
usuwanie soli
Opis:
In recent years, the increasing threat to ground water quality due to human activities has become a matter of great concern. The ground water quality problems present today are caused by contamination and by over exploitation or by combination of both. Reverse osmosis (RO) desalination is one of the main technologies for producing fresh water from sea water and brackish ground water. Algeria is one of the countries which suffer from the water shortage since many years, so desalination technology becomes inevitable solution to this matter. In this study, a comparison is provided of results of reverse osmosis desalination for three different qualities of brackish water from the central-east region of Algeria (Bouira and Setif Prefectures), wherein they cannot use it as human drinking or in irrigation systems. The main objective of our study is to establish a comparison of the reverse osmosis membrane TW30-2540 performances in the term of (permeate flow, recovery rate, permeate total dissolved solids – TDS and salts rejection) under different operation pressures (each one takes a time of 720 second for pilot scaling). In order to make an overview comparison between the experimental and the simulated results we used ROSA (Reverse Osmosis System Analysis) software. At the end of this study we noted that, the simulated results are lower than the pilot scaling values and the most removed salts are the sodium chlorides with 99.05% of rejection rate.
Rosnące zagrożenie dla jakości wód podziemnych w związku z działalnością człowieka rodzi w ostatnich latach poważne obawy. Obecne problemy z jakością wód gruntowych są spowodowane zanieczyszczeniem i nadmierną eksploatacją albo obiema przyczynami łącznie. Odsalanie metodą odwróconej osmozy jest jedną z głównych technologii, mających na celu produkcję wody słodkiej z wody morskiej lub ze słonawych wód podziemnych. Algieria jest jednym z krajów, które od wielu lat cierpią na niedostatek wody. Odsalanie jest więc nieuniknionym rozwiązaniem. Przedstawione badania ukazują porównanie wyników odsalania trzech wód słonawych o różnej jakości pochodzących ze środkowowschodniego regionu Algierii (prefektury Bouira i Setif), gdzie wód tych nie można stosować ani do zaopatrzenia ludności, ani do nawodnień. Głównym celem badań było porównanie działania membrany TW30-2540 mierzonego przepływem, tempem odzysku, przepuszczalnością rozpuszczonych soli i usuwaniem soli w warunkach stosowania różnego ciśnienia (w pilotowym teście każdy wariant trwał 720 s). Do porównania wyników eksperymentalnych i symulowanych użyto programu ROSA (Reverse Osmosis System Analysis). Wartości symulowane były mniejsze niż eksperymentalne wyniki testu pilotażowego, większość usuwanych soli stanowił chlorek sodu. Efektywność jego usuwania wyniosła 99,05%.
Źródło:
Journal of Water and Land Development; 2019, 42; 49-58
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Remediation of laundry wastewater with a low-pressure aromatic polyamide thin-film composite reverse osmosis membrane for membrane fouling minimisation and reuse application
Autorzy:
Morris, Bradley Gareth
Aziz, Mujahid
Kasongo, Godwill
Powiązania:
https://bibliotekanauki.pl/articles/2086908.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reverse osmosis
RO
wastewater effluent
surfactant
odwrócona osmoza
ścieki pralnicze
surfaktant
Opis:
In areas with limited freshwater resources, affordable technologies can remediate greywater for reuse applications and increase the water supply. These wastewaters contain various chemicals, which make them challenging to treat. Reverse osmosis (RO) membrane systems could be the solution to removing these harmful chemicals. Membrane fouling has been investigated and using a commercial antiscalant to treat laundry wastewater effluent with a polyamide (PA) thin-film composite (TFC) reverse osmosis membrane. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR),energy-dispersive X-ray spectroscopy (EDX), and scanning electron microscopy (SEM) were used to assess the antiscalant effects. The anionic surfactant rejection was above 99.8% for experimental tests conducted. The average COD removal rate was in the range of 91-96%, irrespective of the antiscalant dosing. However, the presence of antiscalant at the dose of 8 mg/dm3 significantly reduced fouling intensity. The flux decline ratio amounted to 56 and 72% for the RO process with antiscalant and no antiscalant dosing, respectively.
Źródło:
Environment Protection Engineering; 2022, 48, 2; 43--57
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies for the desalination of model solution of flowback water from shale gas production in the NF/RO pilot plant
Badania nad możliwością odsalania modelowego roztworu płynu powrotnego ze szczelinowania hydraulicznego złóż gazu łupkowego w pilotowej instalacji NF/RO
Autorzy:
Rajewski, J.
Kowalik-Klimczak, A.
Szwast, M.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/257475.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
nanofiltration
NF
reverse osmosis
RO
desalination
flowback water
shale gas
nanofiltracja
odwrócona osmoza
odsalanie
płyn powrotny
gaz łupkowy
Opis:
The impact of selected process parameters of an integrated NF/RO system on possibilities of the desalination of model solutions, containing salts in typical concentrations for flowback water from shale gas production, was analyzed in this work. Based on the results of studies carried out in the pilot scale, it was found that the integrated NF/RO system allows for satisfactory reduction of the model solution of flowback water mineralization. It can be stated that the use of NF/RO system enables the re-use of the “real” flowback water during hydraulic fracturing.
W pracy zbadano wpływ wybranych parametrów procesowych zintegrowanego systemu NF/RO na możliwość odsalania modelowych roztworów zawierających sole w stężeniach charakterystycznych dla płynu powrotnego ze szczelinowania złóż gazu z łupków. Na podstawie otrzymanych wyników badań prowadzonych w skali pilotowej, stwierdzono, że zintegrowany układ NF/RO pozwala na zadowalające zmniejszenie mineralizacji roztworu modelowego płynu powrotnego. Można zatem założyć, iż zastosowanie układu NF/RO umożliwi ponowne wykorzystanie ścieku rzeczywistego podczas szczelinowania hydraulicznego.
Źródło:
Problemy Eksploatacji; 2016, 3; 155-164
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies