Remediation of laundry wastewater with a low-pressure aromatic polyamide thin-film composite reverse osmosis membrane for membrane fouling minimisation and reuse application

Tytuł:
Remediation of laundry wastewater with a low-pressure aromatic polyamide thin-film composite reverse osmosis membrane for membrane fouling minimisation and reuse application
Autorzy:
Morris, Bradley Gareth
Aziz, Mujahid
Kasongo, Godwill
Powiązania:
https://bibliotekanauki.pl/articles/2086908.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
reverse osmosis
RO
wastewater effluent
surfactant
odwrócona osmoza
ścieki pralnicze
surfaktant
Źródło:
Environment Protection Engineering; 2022, 48, 2; 43--57
0324-8828
Język:
angielski
Prawa:
Wszystkie prawa zastrzeżone. Swoboda użytkownika ograniczona do ustawowego zakresu dozwolonego użytku
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
In areas with limited freshwater resources, affordable technologies can remediate greywater for reuse applications and increase the water supply. These wastewaters contain various chemicals, which make them challenging to treat. Reverse osmosis (RO) membrane systems could be the solution to removing these harmful chemicals. Membrane fouling has been investigated and using a commercial antiscalant to treat laundry wastewater effluent with a polyamide (PA) thin-film composite (TFC) reverse osmosis membrane. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR),energy-dispersive X-ray spectroscopy (EDX), and scanning electron microscopy (SEM) were used to assess the antiscalant effects. The anionic surfactant rejection was above 99.8% for experimental tests conducted. The average COD removal rate was in the range of 91-96%, irrespective of the antiscalant dosing. However, the presence of antiscalant at the dose of 8 mg/dm3 significantly reduced fouling intensity. The flux decline ratio amounted to 56 and 72% for the RO process with antiscalant and no antiscalant dosing, respectively.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies