Tytuł:
Analysis and Simulation Performance of a Reverse Osmosis Plant in the Al-Maqal Port
Autorzy:
Yousif, Yasameen T.
Abbas, Abdulhussain A.
Yaseen, Dina Ali
Powiązania:
https://bibliotekanauki.pl/articles/2086424.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
reverse osmosis
Iraq
Basrah
Shatt Al-Arab
TDS
total dissolved solids
Winflows
Opis:
The Basrah province (southern of Iraq) was interested in establishing desalination plants to provide drinking water due to the high levels of salinity in its water resources. This work was carried out in order to evaluate and simulate the functionality of the reverse osmosis plant in the Al-Maqal port. From the field and laboratory measurement, this study concluded that the considered parameters of product water by reverse osmosis (RO) plant were within the Iraqi standard (IRS) limits. The calculation of operation indices showed that the recovery rate of plant (72%) and the permeate flux of plant (20 lmh) was within for limitation of brackish surface water. In turn, the plant has a low salt rejection (90.1%) and a high pressure drop (5 bar); therefore, the membranes require backwashing or chemical cleaning. Then, the performance of RO membrane was simulated by the Winflows software. The best operating parameters were identified. The coefficient of determination (R2) between simulated and measured TDS was 0.83. Therefore, the simulated TDS of permeate multiplied by 5.3 was given a good estimation for actual TDS within acceptable an error rate of 17%.
Źródło:
Journal of Ecological Engineering; 2022, 23, 5; 173--186
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of production of silver nanoparticles using soil fungi and its applications for reducing irrigation water salinity
Autorzy:
Yaseen, Rabaa
Kotp, Yousra H.
Eissa, Doaa
Powiązania:
https://bibliotekanauki.pl/articles/292300.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
antimicrobial activity
dehydrogenase
mycoynthesized nano-silver
nitrate reductase
reverse osmosis
soil salinity
water desalination
Opis:
In the present work, the dried biomass of soil isolated fungus Eurotium cristatum was used for synthesizing silver nanoparticles (AgNPs). The synthesized AgNPs were spherical in shape with average diameter of 16.56 nm and displayed maximum absorbance at 418. Fourier transform infrared (FTIR) study indicated the presence and binding of proteins with myco-produced silver nanoparticles. The optimum conditions for AgNPs biosynthesis were found to be at temperature of 40°C, pH of 8.0, substrate concentration of 500 ppm and fungal biomass wt. of 0.8 g. The AgNPs showed antibacterial activity against Staphylococcus aureus, Listeria monocytogenes, Escherichia coli and Shigella flexneri. AgNPs was built-in thin film nanocomposite (TFNC) membrane and the impacts of nanomaterial composition on membrane properties and desalination process were studied. The AgNPs produced membrane TFNC had better filtration performances than pure thin film composite membrane TFC. The TFNC membrane had enhanced water flux (32.0 vs. 16.5 dm3∙m–2∙h–1) and advanced NaCl rejection (91.7 vs. 89%) compared to the TFC membrane. A pot experiment was conducted to evaluate the effect of the irrigation with desalinated water on yield and productivity of essential oil of the sweet basil (Ocimum basilicum L.) and lavender (Lavandula multifida L.). The irrigation with desalinated water reduced significantly the soil reaction, soil electrical conductivity (EC), sodium adsorption ratio and exchangeable sodium percent in rhizospheric soil, it also enhanced the growth and oil yield of both plants compared with those irrigated with salt water.
Źródło:
Journal of Water and Land Development; 2020, 46; 216-228
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość wody - od ujęcia do wylewki
Water quality - from the intake to the dispenser
Autorzy:
Wojtas, A.
Piotrowska, G.
Dąbek, M.
Powiązania:
https://bibliotekanauki.pl/articles/399624.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
odwrócona osmoza
jakość wody
redukcjia zanieczyszczeń
reverse osmosis process
water quality
reduction of pollutants
Opis:
Podstawowym źródłem zaopatrzenia ludzi w wodę pitną są wodociągi. Jakość ujmowanej do wodociągu wody może ulec pogorszeniu z powodu licznych zanieczyszczeń. Woda, w tym przypadku, powinna być oczyszczana za pomocą filtrów domowych. Najskuteczniejszym urządzeniem doczyszczającym wodę ze szkodliwych związków chemicznych oraz bakterii i wirusów jest zestaw składający się z filtra mechanicznego, sorpcyjnego, odwróconej osmozy i mineralizatora.
Water supply systems are the basic source of potable water. Quality of the water entering a water supply system can be lowered by secondary pollutants. 1fthis is the case, water should be cleaned with the use of home filters. The most effective one in removing all water impurities is a system comprising a mechanical, sorptive, reverse osmosis filter.
Źródło:
Inżynieria Ekologiczna; 2008, 20; 42-49
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of Resource-Saving Technologies in the Use of Sedimentation Inhibitors for Reverse Osmosis Installations
Autorzy:
Trus, Inna
Gomelya, Mukola
Skiba, Margarita
Pylypenko, Tetiana
Krysenko, Tamara
Powiązania:
https://bibliotekanauki.pl/articles/2025383.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
reverse osmosis
concentrate
membrane
permeate
productivity
selectivity
antiscalant
Opis:
The processes of desalination of weakly mineralized waters using a reverse osmosis membrane were studied. The operational efficiency of membranes is limited mainly by membrane contamination. It was shown that the preliminary mechanical water purification helps to increase the productivity and selectivity of the membrane. One of the main causes of membrane contamination is the formation of carbonate deposits on their surface. One way to prevent membrane contamination is to dose antiscalants. It was established that the use of hydrolyzed polyacrylonitrile (HPAN) and hydrolyzed polyacrylamide (HPAA) as a stabilizer of scale formation is effective for concentrates of reverse osmosis desalination of water.
Źródło:
Journal of Ecological Engineering; 2022, 23, 1; 206-215
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Hybrid Uf-RO Process to Geothermal Water Desalination : Concentrate Disposal and Cost Analysis
Wykorzystanie hybrydowego procesuUF-RO w odsalaniu wód geotermalnych : utylizacja koncentratu i analiza kosztów
Autorzy:
Tomaszewska, B.
Pająk, L.
Bodzek, M
Powiązania:
https://bibliotekanauki.pl/articles/204638.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
desalination
geothermal water
reverse osmosis
costs analysis
concentrate disposal
odsalanie
wody geotermalne
odwrócona osmoza
analiza kosztów
utylizacja koncentratu
Opis:
Membrane-based water desalination processes and hybrid technologies are often considered as a technologically and economically viable alternative for desalination of geothermal waters. This has been confirmed by the results of pilot studies concerning the UF-RO desalination of geothermal waters extracted from various geological structures in Poland. The assessment of the feasibility of implementing the water desalination process analysed on an industrial scale is largely dependent on the method and possibility of disposing or utilising the concentrate. The analyses conducted in this respect have demonstrated that it is possible to use the solution obtained as a balneological product owing to its elevated metasilicic acid, fluorides and iodides ions content. Due to environmental considerations, injecting the concentrate back into the formation is the preferable solution. The energy efficiency and economic analysis conducted demonstrated that the cost effectiveness of implementing the UF-RO process in a geothermal system on an industrial scale largely depends on the factors related to its operation, including without limitation the amount of geothermal water extracted, water salinity, the absorption parameters of the wells used to inject water back into the formation, the scale of problems related to the disposal of cooled water, local demand for drinking and household water, etc. The decrease in the pressure required to inject water into the formation as well as the reduction in the stream of the water injected are among the key cost-effectiveness factors. Ensuring favourable desalinated water sale terms (price/quantity) is also a very important consideration owing to the electrical power required to conduct the UF-RO process.
Odsalanie wody z wykorzystaniem procesów membranowych oraz technologii hybrydowych rozważane jest jako technologiczna i ekonomiczna alternatywa dla klasycznych metod utylizacji wykorzystanych wód geotermalnych. Taką możliwość potwierdziły przeprowadzone badania pilotowe odsalania w systemie UF-RO wód geotermalnych eksploatowanych w obrębie różnych struktur geologicznych Polski. Ocena możliwości wdrożenia tych rozwiązań na skalę przemysłową, w dużej mierze zależy od kierunków i możliwości utylizacji/ zagospodarowania koncentratu. Przeprowadzone analizy w tym zakresie wykazały możliwość wykorzystania uzyskanego roztworu jako produktu o cechach balneologicznych, z uwagi na podwyższoną zawartość: kwasu metakrzemowego oraz jonów fluorkowych i jodkowych. Biorąc pod uwagę jednak względy środowiskowe, alternatywnym rozwiązaniem może być wtłaczanie koncentratu do górotworu. Przeprowadzona analiza energetyczna i ekonomiczna wykazała, iż opłacalność wdrożenia na skalę przemysłową procesu UF-RO w systemie geotermalnym w dużej mierze zależy od czynników związanych z jego pracą, a w szczególności: wielkości wydobycia wód geotermalnych, zasolenia wód, parametrów chłonnych otworów przeznaczonych do wtłaczania wód do górotworu, skali problemów związanych z utylizacją schłodzonych wód, lokalnego zapotrzebowania na wody pitne i gospodarcze i in. Kluczowa dla opłacalności tego procesu jest między innymi redukcja wymaganego ciśnienia przy wtłaczaniu wód do górotworu i redukcja wielkości strumienia zatłaczanych wód. Bardzo ważnym elementem jest również zapewnienie odpowiednich warunków zbytu odsolonych wód (cena/ilość) celem pokrycia zapotrzebowania na energię elektryczną wykorzystaną w procesie UF-RO.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 137-151
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wstępne wyniki badań w kierunku uzyskania koncentratu na bazie wybranych wód zmineralizowanych
Preliminary results of tests for obtaining a concentrate based on selected mineralized water
Autorzy:
Tomaszewska, B.
Tyszer, M.
Bodzek, M.
Bujakowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/203551.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
wody mineralne
koncentrat
procesy membranowe
odwrócona osmoza
mineral water
concentrate
membrane processes
reverse osmosis
Opis:
W artykule przedstawiono wyniki badań mających na celu zatężenie składu chemicznego naturalnej zmineralizowanej wody i pozyskanie koncentratu użytecznego dla celów balneologicznych. Pierwotna mineralizacja ogólna badanej surowej wody wynosiła 11 010 mg/dm3 i zawierała 10,06 mg/dm3 kwasu metakrzemowego. W rezultacie zatężania wody, w procesie odwróconej osmozy wyposażonej w membranę BW30FR-400, otrzymano wysokiej jakości nowy produkt. Mineralizacja skoncentrowanej wody mineralnej wynosiła 18 238,5 mg/dm3 przy stężeniu 18,48 mg/dm3 kwasu metakrzemowego. Dodatkowo otrzymano wysokiej jakości permeat, jako produkt możliwy do wykorzystania jako woda przeznaczona do spożycia przez ludzi. Wyniki badań dały nowe światło dla zastosowań technicznych.
The paper presents the results of research aimed at concentrating the mineralized water. The aim of the research was to obtain more concentrated mineral water as concentrates useful for balneological purposes. The mineralization of tested raw mineral water was 11 010 mg/dm3 and contained 2.8 mg/dm3 of boron-and 10.06 mg/dm3 of metasilicic acid. As a result of water concentrating in the RO process with a BW30FR-400 membrane, a high quality of a new product – concentrate has been achieved. The mineralization of concentrated mineral water was a 18 238.5 mg/dm3 with 18.48 mg/dm3 metasilicic acid concentration. In additional the high quality of the permeate was also obtained as a product possible for use as potable water. The results of research gave new light for the technical application.
Źródło:
Technika Poszukiwań Geologicznych; 2016, R. 55, nr 2, 2; 169-178
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagospodarowanie schłodzonych i odsolonych wód termalnych w Podhalańskiej Sieci Ciepłowniczej
Cooled and desalinated thermal water utilization in the Podhale Heating System
Autorzy:
Tomaszewska, B.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/216572.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
odsalanie wody
ultrafiltracja
odwrócona osmoza
geotermia
straty wody sieciowej
ciepłownictwo
water desalination
ultrafiltration
reverse osmosis
geothermics
network water losses
district heating
Opis:
Woda obiegowa w instalacjach ciepłowniczych musi posiadać odpowiednie parametry fizykochemiczne, uzależnione od wymagań technicznych producentów urządzeń, przez które przepływa. Nie powinna powodować powstawania kamienia kotłowego, pienić się oraz korozyjnie oddziaływać na elementy instalacji. W pracy przedstawiono badania dotyczące oceny możliwości wykorzystania odpadowych wód termalnych w celu uzupełnienia ubytków wody sieciowej w największym polskim geotermalnym systemie ciepłowniczym zlokalizowanym w obrębie niecki podhalańskiej. Obszar ten cechuje się dużymi zasobami wód termalnych, a jednocześnie deficytem wód zwykłych. Odpadowe wody termalne ze względu na wykazywane parametry fizykochemiczne mogą być wykorzystane w systemie dopiero po uzdatnieniu. Podczas badań zagospodarowana i uzdatniana była jedynie część całkowitego strumienia wody geotermalnej (do 5 m3/h), odpowiadająca mniej więcej zapotrzebowaniu systemu ciepłowniczego na świeżą uzdatnioną wodę obiegową (ok. 550 m3/miesiąc). Ubytki wody sieciowej wynikają z nieszczelności sieci, prowadzenia remontów, modernizacji lub obsługi sieci. Oczyszczanie przeprowadzone zostało z wykorzystaniem procesów membranowych w zintegrowanym systemie złożonym z ultrafiltracji (UF) i dwóch niezależnych stopni odwróconej osmozy (RO-1 i RO-2) połączonych szeregowo. Uzdatnianie prowadzone było przy częściowym wykorzystaniu artezyjskiego ciśnienia złożowego, co pozwoliło zredukować moc pomp obiegowych eliminując zużycie energii o około 0,7–0,9 kW. Dzięki podwyższonej temperaturze wody uzdatnionej zredukowana została moc cieplna o około 30 kW oraz efektywniej prowadzone były procesy oczyszczania i odgazowania wody. Uzyskano redukcję: zawartości żelaza ze stężenia około 4 do 0,013 g/m3, twardości ogólnej z 13,5 val/m3 do <0,02 val/m3, zasadowości z 4,45 val/m3 do <0,01 val/m3, fosforanów z 0,03 do <0,006 g/m3, uzyskując spełnienie wymagań określonych w normach, co po korekcie pH i odgazowaniu pozwala wykorzystać uzdatnione wody geotermalne dla uzupełnienia ubytków wody sieciowej w systemie ciepłowniczym. Polska Norma PN-85/C-04601 nie specyfikuje wymagań w zakresie dopuszczalnego stężenia m.in. chlorków i siarczanów w wodzie obiegowej, a więc anionów wpływających na korozyjność wody, głównie wżerową. Jony te tworzą rozpuszczalne związki z metalami, utrudniając powstawanie i wytrącanie tlenków metali. Zastosowanie przedstawionej technologii membranowej w odsalaniu wód termalnych pozwoliło na uzyskanie wysokiego stopnia retencji. Wynosi on dla chlorków 97% po RO-1 i 99% po RO-2, natomiast dla siarczanów 99% już po RO-1.
Distribution water that circulates in heating installations must meet certain parameters depending on the technical requirements set by the manufacturers of the equipment through which it flows. It should not cause scaling of boilers, should not corrode parts of the installation and should not foam. This paper examines the proposition the used of geothermal water to replenish network water losses in the largest Polish geothermal heating system located within the Podhale Basin reservoir. The area in question has considerable geothermal water resources while at the same time exhibiting a fresh water deficit. Only part of the total volume of geothermal water (up to 5 m3/h) was used and treated; this is roughly equivalent to the district heating system demand for treated fresh distribution water (ca. 550 m3/month). The treatment uses membrane processes within the framework of a integrated arrangement including ultrafiltration (UF) and two independent reverse osmosis stages (RO-1 and RO-2) connected in series. Artesian pressure was used to a certain extent during the treatment, which makes it possible to reduce the power required for the distribution pump, decreasing electrical power consumption by ca. 0.7–0.9 kW. Thanks to the fact that the temperature of the water to be treated is higher than the public supply, the thermal capacity requirement was reduced (30 kW) and both water treatment and degassing processes are more efficient. Iron content was reduced from ca. 4 to 0.013 g/m3, total hardness was reduced from 13.5 eq/m3 to <0.02 eq/m3, alkalinity was reduced from 4.45 eq/m3 to <0.01 eq/m3 and phosphate content was reduced from 0.03 to <0.006 g/m3. Thus the requirements set forth in the standards have been met and the treated geothermal water can be used to replenish network water losses in the district heating system following pH adjustment and degassing. The PN-85/C-04601 Polish Standard does not specify any requirements concerning the admissible concentrations of, inter alia, chloride and sulphate ions, i.e. anions that affect water corrosivity, mostly pitting corrosivity. These ions form soluble compounds with metals and thereby inhibit the formation and precipitation of metal oxides. The use of the membrane technology discussed here in the desalination of geothermal waters, also made it possible to achieve high retention coefficients – 97% after RO-2 for chlorides and 99% for sulphates already after RO-1.
Źródło:
Gospodarka Surowcami Mineralnymi; 2013, 29, 1; 127-139
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of modified coal through chemical activation process on performance of heterogeneous reverse osmosis membranes
Autorzy:
Thaçi, B.
Gashi, S.
Daci, N.
Daci, M.
Dylhasi, A.
Powiązania:
https://bibliotekanauki.pl/articles/207269.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chemical activation
coal
membranes
reverse osmosis
wastewater treatment
reverse osmosis treatment
aktywacja chemiczna
węgiel
membrany
odwrócona osmoza
oczyszczanie ścieków przemysłowych
Opis:
Heterogeneous reverse osmosis (RO) membranes have been prepared from cellulose acetate (CA) and modified coal through chemical activation. Nitric acid of various concentrations, sulfuric and acetic acids used for various time periods have been studied with respect to modification of structure of coal and consequently structure of RO membranes. The effect of these variables on the modification of coal was examined by IR spectroscopy. All membranes prepared in such a way showed improved performance in comparison with standard CA membranes. The volume flux of the best RO membranes at 94% level of solute separation was 3.87×10–2 m3/(m2·h) at 1.76 MPa using aqueous feed solution 400 mg/dm3 of sodium chloride. The performance improvement was related to increases of charge of groups of coal particles in the membrane, affecting their rheology and morphology resulting in better membrane productivity. The SEM of some membranes have also been presented. These membranes were tested also with 1:1, 1:2, 2:2 and 1:3 inorganic salt solutions. The agreement between the calculated and experimental data of solute separation for studied solutes was reasonably good.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 53-65
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality of Leachate From Landfill with Reverse Osmosis Concentrate Recirculation
Autorzy:
Tałałaj, Izabela Anna
Powiązania:
https://bibliotekanauki.pl/articles/124364.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
landfilling
leachate
concentrate recirculation
reverse osmosis
Opis:
The purpose of this study was to determine the changes of leachate quality on a selected municipal landfill with recirculation of concentrate from the reverse osmosis (RO) process. The research was carried out on an exploited municipal waste landfill, from which the samples of leachate, permeate and concentrate were collected in the years 2013-2015. The obtained samples were subjected to the physicochemical analysis, including the determination of general pollution parameters as well as organic and inorganic indicators. The obtained results showed that the concentrate recirculation resulted in intensification of the degradation processes in the waste body, expressed by the increase of biodegradability rate (BOD5/COD) and the value of conductivity and dissolved solids. Over time, the value of conductivity and dissolved solids stabilized; however, they reached the values higher than in conventional landfills. A characteristic feature of the long-recirculation landfills was a continuous increase in the concentration of ammonia nitrogen and COD values in the leachate.
Źródło:
Journal of Ecological Engineering; 2019, 20, 8; 205-211
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Leachate Quality on Reverse Osmosis Performance
Wpływ jakości odcieków na parametry pracy odwróconej osmozy
Autorzy:
Tałałaj, I. A.
Biedka, P.
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/1813657.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
leachate treatment
municipal landfill
reverse osmosis
oczyszczanie odcieków
składowisko odpadów
odwrócona osmoza
Opis:
In paper an influence of leachate from landfills with different exploitation time on reverse osmosis performance during their treatment was presented. An unstabilized leachate from landfill of two years exploitation and stabilized leachate from landfill with operation time over 10 years were taken to analysis. The analyses were conducted with use of RO system constructed to reflect the actual operating conditions of the reverse osmosis system exploited on municipal landfills. These two kind of leachate was directed to the reverse osmosis system by maintaining during their filtration the same operating parameters (temperature, pressure, flow rate, recovery rate and pH of leachate). The obtained results indicated that filtration of stabilized leachate is characterized by better performance of the RO system, i.e. shorter filtration time, higher permeate flow and higher salt retention. The higher concentration of organic matter in unstabilized leachate contributes to membrane pores blocking decreases the efficiency of the osmotic system. Moreover, high organic content in the leachate from young landfills, with a high concentration of cations, leads to an unfavorable phenomenon of neutralization of the membrane surface.
W pracy przedstawiono wpływ odcieków ze składowisk o różnym czasie eksploatacji na parametry pracy odwróconej osmozy podczas ich oczyszczania. Do badań przyjęto nieustabilizowane odcieki ze składowiska o 2-letnim czasie eksploatacji oraz odcieki ustabilizowane ze składowiska o czasie eksploatacji przekraczającym 10 lat. Analizy prowadzono na układzie odwróconej osmozy, skonstruowanym w ten sposób by odzwierciedlać rzeczywiste warunki pracy układów eksploatowanych na składowiskach odpadów. Odcieki skierowano na układ RO zachowując podczas ich filtracji te same parametry pracy (temperatura, ciśnienie, przepływ, stopień odzysku oraz odczyn odcieków). Uzyskane wyniki wskazały, że proces filtracji odcieków ustabilizowanych charakteryzuje się lepszymi parametrami pracy układu RO, tj. krótszy czas filtracji, wyższy przepływ permeatu oraz wyższy stopień retencji soli. Większa zawartość substancji organicznych zawartych w odciekach młodych (nieustabilizowanych) przyczynia się do blokowania porów membrany i obniża wydajność układu osmotycznego. Ponadto wyższa zawartość substancji organicznej w odciekach z młodych składowiska oraz wyższe stężenie w nich kationów prowadzi do niekorzystnego zjawiska neutralizacji powierzchni membrany.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 1; 634-646
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie odwróconej osmozy w procesie oczyszczania odcieków
Treatment of landfill leachate with reverse osmosis
Autorzy:
Tałałaj, I.
Powiązania:
https://bibliotekanauki.pl/articles/908533.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
jakość odcieków
odwrócona osmoza
oczyszczanie odcieków
leachate quality
reverse osmosis
leachate treatment
Opis:
Składowanie odpadów jest wciąż najbardziej powszechną metodą ich unieszkodliwiania. Szacuje się, że na świecie postępuje się tak z 95% wytworzonych odpadów. Podczas składowania w bryle odpadów zachodzi szereg procesów fizyczno- chemicznych oraz biologicznych. Rozkład materii organicznej w połączeniu z infiltracją wód opadowych prowadzi do wymywania z niej silnie zanieczyszczonych wód, zwanych odciekami.2 Skład odcieków i stężenie w nich zanieczyszczeń zależy głównie od rodzaju składowanych odpadów, sposobu eksploatacji składowiska oraz czasu składowania.
One of landfill’s product is leachate, which is highly and complexly polluted wastewater. Landfill leachate, especially old one is very difficult to treat using conventional biological processes. One of the methods to be used in the treatment of such leachate is reverse osmosis. This paper compares the effectiveness of reverse osmosis in removing BOD5, COD, NH3-N and selected heavy metals. Efficiency of leachate treatment by one-and two-stage reverse osmosis system was characterized. The effects of the membrane type on the purification are also described. The influence of the waste quality on leachate treatment efficiency and the risks associated with the use of reverse osmosis in the leachate treatment were also described.
Źródło:
Ekonomia i Środowisko; 2013, 2; 95-106
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of pesticides and inorganic pollutants by reverse osmosis
Autorzy:
Šír, M.
Podhola, M.
Patočka, T.
Honzajková, Z.
Kocurek, P.
Bystrianský, M.
Vurm, R.
Kubal, M.
Powiązania:
https://bibliotekanauki.pl/articles/207770.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
groundwater
groundwater pollution
pesticides
reverse osmosis
water treatment
batch process
chlorinated pesticides
inorganic pollutants
polyamide membranes
wody gruntowe
zanieczyszczenie wód gruntowych
pestycydy
odwrócona osmoza
uzdatnianie wody
proces wsadowy
chlorowane pestycydy
zanieczyszczenia nieorganiczne
membrany poliamidowe
Opis:
Contamination of soil and groundwater with pesticides is mainly caused by old ecological burdens. This study focuses on the treatment of groundwater contaminated with chlorinated pesticides. The contaminants mainly include α-HCH, β-HCH, γ-HCH, HCB, DDE, DDD and DDT. Reverse osmosis technology using RO98pHt polyamide membranes was used to remove the pollutants under batch process conditions. The observed rate of removal ranged from 98.4% to 99.7%. Total dissolved content solids decreased from 1.35 g/dm3 to below 0.05 g/dm3.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 159-166
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies for the desalination of model solution of flowback water from shale gas production in the NF/RO pilot plant
Badania nad możliwością odsalania modelowego roztworu płynu powrotnego ze szczelinowania hydraulicznego złóż gazu łupkowego w pilotowej instalacji NF/RO
Autorzy:
Rajewski, J.
Kowalik-Klimczak, A.
Szwast, M.
Gierycz, P.
Powiązania:
https://bibliotekanauki.pl/articles/257475.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
nanofiltration
NF
reverse osmosis
RO
desalination
flowback water
shale gas
nanofiltracja
odwrócona osmoza
odsalanie
płyn powrotny
gaz łupkowy
Opis:
The impact of selected process parameters of an integrated NF/RO system on possibilities of the desalination of model solutions, containing salts in typical concentrations for flowback water from shale gas production, was analyzed in this work. Based on the results of studies carried out in the pilot scale, it was found that the integrated NF/RO system allows for satisfactory reduction of the model solution of flowback water mineralization. It can be stated that the use of NF/RO system enables the re-use of the “real” flowback water during hydraulic fracturing.
W pracy zbadano wpływ wybranych parametrów procesowych zintegrowanego systemu NF/RO na możliwość odsalania modelowych roztworów zawierających sole w stężeniach charakterystycznych dla płynu powrotnego ze szczelinowania złóż gazu z łupków. Na podstawie otrzymanych wyników badań prowadzonych w skali pilotowej, stwierdzono, że zintegrowany układ NF/RO pozwala na zadowalające zmniejszenie mineralizacji roztworu modelowego płynu powrotnego. Można zatem założyć, iż zastosowanie układu NF/RO umożliwi ponowne wykorzystanie ścieku rzeczywistego podczas szczelinowania hydraulicznego.
Źródło:
Problemy Eksploatacji; 2016, 3; 155-164
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reverse osmosis application in the recycling of zinc from the electroplating shop wastewater
Autorzy:
Porębski, T.
Tomzik, S.
Ratajczak, W.
Talma-Piwowar, M.
Koprowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/779885.pdf
Data publikacji:
2007
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
ścieki pogalwaniczne
odzysk cynku
procesy membranowe
osmoza odwrócona
galvanic wastewater
zinc recovery
membrane process
reverse osmosis
Opis:
The paper reveals the results of the research on the reverse osmosis recovery of zinc from galvanic electroplating. The pilot plant tests were performed in an electroplating shop. Raw washings were concentrated with a spiral wound 2.5x40" module with a composite polymeric membrane. The research tests have proved that the proposed RO process enables successful concentration of the non-ferrous metal in raw washings. The retentate of the RO process has contained about 96% of the metal previously wasted in washings discharged to the environment. The retentate can be recycled to the mother electroplating process. The permeate of the RO process can be recycled to the washing system of the electroplating shop.
Źródło:
Polish Journal of Chemical Technology; 2007, 9, 2; 90-93
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie technologii uzdatniania wody pod względem skuteczności obniżenia stężenia azotanów w wodzie do picia
Comparisonof water treatment technologiesin terms of reduction efficiencyofnitrates concentrationin drinking water
Autorzy:
Pławszewski, K.
Mniszek, W.
Powiązania:
https://bibliotekanauki.pl/articles/370745.pdf
Data publikacji:
2013
Wydawca:
Wyższa Szkoła Zarządzania Ochroną Pracy w Katowicach
Tematy:
azotany w wodzie
wymienniki jonitowe
system odwróconej osmozy
nitrates in water
ion exchangers
reverse osmosis system
Opis:
Woda pitna jest źródłem życia, ale zła jakość wody, która nie spełnia wymagań dla wody pitnej może być zagrożeniem dla zdrowia człowieka. Z tego powodu woda surowa musi być uzdatniana. W analizowanych ujęciach wody dopuszczalne stężenia azotanów w wodzie zostały przekroczone. Celem niniejszego artykułu jest porównanie dwóch różnych metod usuwania azotanów z wydobywanej wody i wskazanie tej, która umożliwia utrzymać parametry wymagane przez prawo i chronić obywateli przed zagrożeniami zdrowia. Porównywane metody to wymiana jonowa i odwrócona osmoza.
Potable water isthe source of life, but the poor quality ofwater thatdoes not meet therequirementsfor drinking watercanbe hazardousto human health. For this reason,the raw watermust betreated.In the analyzedwater intakeslimitsfor nitrates inthe waterwere exceeded. The purpose of thispaper is to comparetwo differentmethods of removingnitratefromwaterminedand identifythe one thatallows you tokeepthe parameters requiredby the law andprotectcitizens againsthealththreats. Methods comparedareion exchangeandreverse osmosis.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach; 2013, 1(9); 15-27
1895-3794
2300-0376
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies