Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "respiratory signal" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Comparing methods of ECG respiration signals derivation based on measuring the amplitude of QRS complexes
Autorzy:
Kikta, A.
Augustyniak, P.
Powiązania:
https://bibliotekanauki.pl/articles/333821.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
EKG
sygnał oddechowy
wykrywanie bezdechu
ECG
EDR
respiratory signal
apnea detection
Opis:
This paper presents the study of algorithms for derivation of respiration waveform from the electrocardiogram. The problem has considerable clinical impact, because the heart rate and respiration are both driven by the central nervous system, and commonly used low-cost Holter recording may be used for efficient detection of breath disturbances (e.g. apnea). Three methods based on: heart rate, heart position and lung resistance influencing the ECG amplitude were compared in our research. Among 18 volunteers breathing at a controlled frequency all implemented algorithms show acceptable sensitivity of order of 97% in slow breathing phases detection. In fast breathing the sensitivity is reduced to 90%, since the heart beats are too sparse with regard of respiration waveform.
Źródło:
Journal of Medical Informatics & Technologies; 2007, 11; 155-163
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie częstości oddychania na podstawie analizy obwiedni amplitudowej sygnału PPG
Determination of respiratory rate based on analysis of the envelope of PPG signal
Autorzy:
Wilk, B.
Powiązania:
https://bibliotekanauki.pl/articles/154935.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sygnał PPG
częstość oddychania
obwiednia PPG
PPG signal
respiratory rate
envelope of PPG
Opis:
W artykule przedstawiono metodę wyznaczania częstości oddychania na podstawie analizy górnej obwiedni amplitudowej sygnału PPG, który reprezentuje falę tętna obwodowego w palcu ręki. Obwiednię uzyskano w wyniku aproksymacji lokalnych maksimów splajnami. Opracowana metoda umożliwia określenie czasu trwania każdego cyklu oddechowego oraz pozwala wykryć bezdech. Do oceny dokładności tej metody wykorzystano sygnał referencyjny, który reprezentuje przepływ powietrza w czasie oddychania.
This paper presents a novel method for the estimation of respiratory rate by analyzing the amplitude envelope of a peripheral pulse wave. To record a pulse wave at the finger of the hand a transmission-type photoplethysmographic (PPG) sensor was used. The PPG sensor is sensitive to variations in blood volume. Variations in blood volume are caused by cardiovascular regulation, thermoregulation and respiration. PPG signals show significant morphological differences under the normal and induced apnea conditions (Fig.2). The amplitude fluctuations of PPG were found to drop under apnea (Fig.3).The amplitude envelope of the PPG signal was obtained by interpolating every interval [maxi, maxi + 1] with a cubic polynomial function (Figs. 1 and 3). The breathing rate determined from the airflow signal recorded simultaneously with the PPG signal, served as a reference value (Fig. 5). The results show that the proposed method is a promising technique for detection of each respiratory period, for calculating a respiratory rate, and for detecting apnea (Fig. 5, Fig. 7).
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 12, 12; 1298-1300
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
EtCO2 -Based Biofeedback Method of Breath Regulation Increases Speech Fluency of Stuttering People
Autorzy:
Stankiewicz, B.
Zieliński, K.
Darowski, M.
Michnikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/176680.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stuttering therapy
respiratory disturbances
end-tidal CO2
acoustic signal of an utterance
visual feedback
Opis:
Respiratory disturbances frequently accompany stuttering. Their influence on lung ventilation can be assessed by measurement of the end-tidal CO2 concentration (EtCO2). The effectiveness of the CO2-based visual feedback method of breath regulation (VF) designed for stuttering therapy was tested in this study. The aim of the study was to answer the question if the VF helps to reduce respiratory disturbances in stuttering and increase speech fluency. 20 stuttering volunteers aged 13–45 years took part in the 3-parts test consisting of: 1. speaking without any techniques improving speech fluency, 2. learning the VF method, 3. VF-assisted speaking. The CO2/time signal and an acoustic signal of an utterance were recorded during the test. Significant increase of FE – the factor of breath ergonomics during speaking (based on both signals), from 47% to 71% (P < 0.01), and significant decrease of %SS – the percent of syllables stuttered, from 14% to 10% (P < 0.01) were received for VF-assisted utterances compared to the utterances without VF assistance. The results indicate that the VF can help to eliminate respiratory disturbances in stuttering and increase speech fluency.
Źródło:
Archives of Acoustics; 2015, 40, 4; 469--474
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie częstości oddychania na podstawie analizy widmowej zmienności okresu sygnału fotopletyzmograficznego
Determination of the respiratory rate based on spectral analysis of the PPG period variability
Autorzy:
Wilk, B.
Pazowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/154953.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
częstość oddychania
sygnał PPG
analiza falkowa
metoda Burga
respiratory rate
PPG signal
wavelet analysis
Burg's method
Opis:
W artykule opisano algorytm do wyznaczania częstości oddychania na podstawie analizy widmowej sygnału reprezentującego zmienność okresu fali tętna. Falę tętna zarejestrowano za pomocą czujnika fotopletyzmograficznego (tzw. PPG) umieszczonego na placu ręki. Do przetwarzania sygnału PPG zaproponowano zastosowanie analizy falkowej. Przeprowadzono także ocenę dokładności opracowanej metody wykorzystując sygnał referencyjny, który reprezentuje przepływ powietrza w czasie wydechu.
The arterial pressure waveform contains valuable information regarding the respiratory rate. This paper describes the algorithm developed for estimating the respiratory rate by analyzing the period variability of the peripheral pulse wave. To record a pulse wave at the finger, a transmissiontype photoplethysmographic sensor was used. PPG signals were collected from 10 healthy subjects during free breathing, and breath holding over a period of 3-min using a data acquisition system (Fig. 1). The reference breathing rate was determined from the airflow signal recorded simultaneously with the PPG signal (Figs. 7 and 8). Firstly, the PPG signal was detrended and denoised using the wavelet transform (Fig. 2 and 3). Based on the locations of the maximum points, all periods were detected and the tachogram was constructed. The signal representing the period variability (PPV) was obtained by interpolating the envelope of the tachogram with a cubic polynomial function (Fig. 5). Then, fluctuations extracted by the DWT from the PPV signal were segmented into 10 s intervals. Using Burg’s method, the AR model based PSD was computed for each segment. Finally, the respiratory component was detected as the maximum in the frequency band of 0.150.4 Hz (Fig. 6). The obtained results show (Fig. 9) that the proposed method allows us to monitor the respiratory rate and to detect the induced apnea with the acceptable accuracy.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 610-613
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies