Wyświetlanie 1-44 z 44
Tytuł:
Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT
Autorzy:
Wrzesień, Małgorzata
Olszewski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2161887.pdf
Data publikacji:
2017-07-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
thermoluminescence
panoramic radiography
absorbed dose
CBCT
cephalometric radiography
thermoluminescent detectors
Opis:
Objectives Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT). Material and Methods The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD) in 18 anatomical points of the phantom. Results The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5):705–713
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2017, 30, 5; 705-713
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic neutron radiography studies of drying of kaolin clay cylinders
Autorzy:
Fijał-Kirejczyk, I.
Milczarek, J. J.
Banaszak, J.
Trzciński, A.
Żołądek, J.
Powiązania:
https://bibliotekanauki.pl/articles/148084.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
drying
kaolin
neutron radiography
Opis:
The results of neutron radiography studies on convective drying of kaolin cylinders are presented. The sample shrinkage and loss of water during drying was easily observed on registered neutron radiograms. The saturation of the sample with water was estimated in terms of the neutron effective macroscopic cross-section. The results are comparable to those of gravimetric measurements and are discussed within the framework of simple theories of drying. The effect of the scattered neutrons is discussed in terms of the results of the MC simulations.
Źródło:
Nukleonika; 2009, 54, 2; 123-128
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Asymptomatic radiological changes in computer tomography in children with head trauma
Autorzy:
Marciniak, Aleksandra
Mielnik-Niedzielska, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1397807.pdf
Data publikacji:
2019
Wydawca:
Index Copernicus International
Tematy:
child
maxillary sinus
radiography
Opis:
Introduction: Computed tomography is an important imaging technique in Emergency Units. Thanks to its popularity, radiological changes are found in healthy children more commonly. The aim of this paper is to evaluate the incidence of maxillary sinus radiological changes in children with head trauma who admitted to the Emergency Unit of the University Children Hospital in Lublin. Material and Methods: A retrospective analysis of computed tomography scans of children suffering from head trauma admitted to the Emergency Unit of the University Children Hospital in Lublin was carried out. A group of 425 patients was analyzed. Results: Maxillary findings were present in 81 cases (19.06%); in 38 patients (8.94%) the changes were unilateral, while in 43 (10.12%) they were bilateral. Maxillary mucosal thickening was the most common radiological abnormality, present in almost 12% of the investigated cases (approximately 62% of all revealed changes). Maxillary total opacification as an isolated finding was found in younger children only. Retention cysts and maxillary polyps were found with a similar low frequency as maxillary opacification but in elder children only. Discussion: Asymptomatic radiological changes in computed tomography scans are common. Maxillary mucosal thickening is the most frequent asymptomatic abnormality. Maxillary polyps and pseudocysts are rare in the paediatric population. Maxillary opacification suggests other more significant pathologies and requires further diagnostics. Physicians should avoid diagnosing patients with sinusitis without proper examination and based on radiological abnormalities only. Paediatric patients with revealed maxillary changes should remain under regular laryngological control.
Źródło:
Polish Journal of Otolaryngology; 2019, 73, 5; 5-11
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detektory promieniowania stosowane w cyfrowej radiografii bezpośredniej
Radiation detectors used in Digital Direct Radiography
Autorzy:
Mackiewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/107842.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiografia cyfrowa
panele płaskie
radiografia bezpośrednia DR
digital radiography
flat panel detectors
direct radiography DR
Opis:
W artykule opisano podstawy działania detektorów promieniowania stosowanych w cyfrowej radiografii bezpośredniej - DR. Scharakteryzowano różne rodzaje paneli płaskich pod kątem ich przydatności w obszarze badań nieniszczących. W sposób bardziej szczegółowy omówiono panele płaskie z przemianą pośrednią oparte na matrycy a-Si z tranzystorami TFT, które wykazują obecnie największą przydatność do zastosowań w badaniach nieniszczących. Przeanalizowano najważniejsze parametry paneli płaskich w aspekcie ich zastosowań do badań złączy spawanych oraz innych wyrobów i elementów badanych dotychczas tradycyjną metodą radiograficzną.
The article describes the basics of radiation detectors used in direct digital radiography - DR. Various types of flat panel detectors (FPD) have been characterized for their usefulness in non-destructive testing. The indirect panels based on the a-Si matrix with TFT transistors, which are currently the most useful option for non-destructive testing, are discussed in more detail. The most important parameters of flat panel detectors have been analyzed in the aspect of their applications for the examination of welded joints and other products tested so far by traditional radiographic method.
Źródło:
Badania Nieniszczące i Diagnostyka; 2017, 1-2; 44-51
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A portable fast neutron radiography system for non-destructive analysis of composite materials
Autorzy:
Kam, Erol
Reyhancan, Iskender A.
Biyik, Recep
Powiązania:
https://bibliotekanauki.pl/articles/148503.pdf
Data publikacji:
2019
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast neutron
radiography
scintillator
recoil protons
Opis:
Depending on the neutron energy used, neutron radiography can be generally categorized as fast and thermal neutron radiography. Fast neutron radiography (FNR) with neutron energy more than 1 MeV opens up a new range of possibilities for a non-destructive examination when the inspected object is thick or dense. Other traditional techniques, such as X-ray, gamma ray and thermal neutron radiography, do not meet penetration capabilities of FNR in this area. Because of these distinctive features, this technique is used in different industrial applications such as security (cargo investigation for contraband such as narcotics, explosives and illicit drugs), gas/liquid fl ow and mixing and radiography and tomography of encapsulated heavy shielded low Z compound materials. The FNR images are produced directly during exposure as neutrons create recoil protons, which activate a scintillator screen, allowing images to be collected with a computer-controlled charge-coupled device camera. Finally, the picture can be saved on a computer for image processing. The aim of this research was to set up a portable FN R system and to test it for use in non-destructive testing of different composite materials. Experiments were carried out by using a fast portative neutron generator Thermo Scientific MP 320.
Źródło:
Nukleonika; 2019, 64, 3; 97-101
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Carpometacarpal subchondral cysts due to repetitive movements in shoemaker: A case report
Autorzy:
Tonini, Stefano
Candura, Stefano M.
Lanfranco, Andrea
Mennoia, N. V.
Powiązania:
https://bibliotekanauki.pl/articles/2185380.pdf
Data publikacji:
2011-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
UE-WMSDs
shoe industry
wrist
radiography
Opis:
Objectives: Subchondral carpometacarpal cysts are classic and almost pathognomonic lesions found in workers using vibrating instruments over prolonged periods of time. Materials and Methods: We present the case of a 53-year-old woman who worked for 30 years sewing shoe uppers, a task which required grasping fi rmly a pear-shaped handle awl and pushing it through the leather upper and the sole of the shoe, with combined fl exion and supination movement of the wrist. After approximately 20 years of working, the patient noted gradual onset of paresthesias in the dominant (right) hand, with increasing diffi culty in grasping the awl. Subsequent diagnosis of carpal tunnel syndrome was confi rmed by electrophysiologic testing and its surgical release was performed. Nevertheless, hand pain, paresthesias and weakness persisted. Results: Ultrasound of the snuffbox tendons excluded DeQuervain tenosynovitis. Radiographic imaging of the symptomatic hand showed carpometacarpal subchondral cystic formations. Conclusions: In addition to demonstrating the usefulness of radiographic imaging in patients with persistent hand pain post-carpal release, this case is important in illustrating that repetitive movements with high pressure over the palmar carpal area may cause bone cysts, even if the subjects do not use vibrating tools.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2011, 24, 4; 414-417
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiograficzne i termograwimetryczne badania pirolizy pojedynczej cząstki drewna
Pyrolysis analysis of a single wood particle
Autorzy:
Kaźmierski, P.
Wardach-Święcicka, I.
Tiutiurski, P.
Kardaś, D.
Powiązania:
https://bibliotekanauki.pl/articles/2073378.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
piroliza
radiografia
termograwimetria
pyrolysis
radiography
thermogravimetric analysis
Opis:
Opisano proces pirolizy pojedynczej cząstki drewna. Za pomocą termograwimetrii, badań w piecu wysokotemperaturowym oraz metod radiograficznych przeprowadzono analizę procesu pirolizy. Analizowano szybkość dekompozycji termicznej i jej stopień w funkcji czasu. Badano poddane pojedyncze próbki w formie sosnowych sześcianów o boku 18 mm. Analiza termograwimetryczna mająca na celu wyznaczenie przedziałów, w jakich zachodzi proces, poprzedziła badania wykonane w piecu wysokotemperaturowym. Próbki po eksperymentach zostały poddane badaniom radiograficznym celem zobrazowania zmian gęstości drewna w funkcji czasu. Na zdjęciach zaobserwowano, iż piroliza zachodzi od naroży próbki, a następnie pozostaje tylko niespirolizowany rdzeń w środku próbki. Badania potwierdziły duże możliwości radiografii w ocenie pirolizy.
Pyrolysis process of a single wood particie is described in the paper. Thermogravimetric and radiography techniques and pyrolysis in a high-temperature kiln were applied in the experiments. The thermal decomposition rate as a function of time was analyzed. Pine cubes with a side of 18 mm were used as samples. High-temperature kiln tests were preceded by thermogravimetric analysis aiming to determine temperature ranges in which the process took place. The samples after tests were analyzed using radiographic methods to visualize the changes in wood density as a function of time. It was observed on the photographs that pyrolysis started from sample corners, while only a core in the center of samples remained unchanged. Radiography experiments have a big potential in pyrolysis research.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 6; 202--204
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionising Radiation in Non-destructive Testing, Part 1 Types of Radiation used for Radiographic Testing – Basic Properties and Mechanism of Image Recording
Autorzy:
Ostromęcka, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/27311594.pdf
Data publikacji:
2023
Wydawca:
Instytut Kolejnictwa
Tematy:
ionising radiation
non-destructive testing
industrial radiography
Opis:
Electromagnetic radiation, which is a special example of the electromagnetic field, has been present in the universe since its creation. Examples of radiation include radio waves, X-rays, and visible light. Depending on the frequency of the emitted electromagnetic wave, it can be ionising or non-ionising. Ionising radiation, due to its ability to penetrate matter, is often used in many areas of life. In industry, it is used for diagnostic purposes, e.g. in radiography.
Źródło:
Problemy Kolejnictwa; 2023, 198; 141--146
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Artefakty w radiografii
Artifacts in radiography
Autorzy:
Brandt, Łukasz
Borkowska, Eliza
Herman-Sucharska, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/2146777.pdf
Data publikacji:
2020
Wydawca:
Indygo Zahir Media
Tematy:
radiografia
artefakt
błąd techniczny
radiography
artifact
technical error
Opis:
W dobie dzisiejszych aparatów rentgenowskich wykonanie idealnego zdjęcia radiologicznego może wydawać się prostym zadaniem. Jednak nawet najbardziej doświadczeni technicy elektroradiologii pracownicy w swojej praktyce spotykają problem artefaktów na obrazach. Ich wystąpienie niejednokrotnie utrudnia lub uniemożliwia postawienie właściwej diagnozy, przez co badania takie muszą być powtarzane, prowadząc do zwiększenia narażenia pacjenta na promieniowanie jonizujące. Znajomość charakterystycznych cech poszczególnych typów artefaktów oraz źródeł ich powstawania jest kluczem do uzyskania poprawnych, diagnostycznych obrazów.
In the age of today’s X-ray machines, taking the perfect image may seem like a simple task. However, even the most experienced radiogrphers face the problem of artifacts in the X-ray images in their practice. Their occurrence often makes it difficult or impossible to make a proper diagnosis, therefore such tests must be repeated, leading to an increased patient’s exposure to ionizing radiation. Knowing the characteristic features of types of artifacts and the sources of their formation is the key to obtaining correct, diagnostic images.
Źródło:
Inżynier i Fizyk Medyczny; 2020, 9, 5; 335--342
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal neutron radiography studies of drying of rectangular blocks of wet mortar
Autorzy:
Fijał-Kirejczyk, I. M.
Milczarek, J. J.
de Beer, F. C.
Radebe, M. J.
Nothnagel, G.
Żołądek-Nowak, J.
Powiązania:
https://bibliotekanauki.pl/articles/146714.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
drying
capillary-porous media
mortar
thermal neutron radiography
Opis:
The convectional drying of rectangular block of wet mortar was investigated with thermal neutron radiography technique supplemented with traditional mass and temperature measurements. The time evolution of the drying process was recorded for rectangular sample of aged mortar before and after painting its lateral sides. The receding boundary of the central core wet region was observed in the advanced stage of the process. The size, shape and water content of that region were determined for both cases of non-painted and painted sample. It was shown that in the advanced drying process the receding drying front exists irrespectively of the drying pattern observed at the early period of drying.
Źródło:
Nukleonika; 2012, 57, 4; 529-535
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic neutron radiography studies of water migration in beds of natural zeolite
Autorzy:
Żołądek, J.
Milczarek, J. J.
Fijał-Kirejczyk, I.
Powiązania:
https://bibliotekanauki.pl/articles/148241.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
natural zeolites
water migration
granular media
neutron radiography
Opis:
The results of the experiments on water migration in unsaturated beds of natural zeolite (clinoptilolite) performed with a dynamic neutron radiography technique are presented. It was found that the migration of water in zeolites is much slower than in quartz sand composed of the same size grains. The effect is attributed to the enormous grain surface roughness of the zeolite. The influence of gravity was found to be significant only for beds formed by the coarsest grains. It was found that the water imbibition rate increases with time in finest grain zeolite beds. The results show the difficulties of the classical theory of adhesion driven motion of the liquid in the single capillary as a model of water imbibition by zeolite beds.
Źródło:
Nukleonika; 2008, 53, suppl. 2; 113-119
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A radiographic facility at the Soltan Institute for Nuclear Studies (SINS) at Świerk, Poland
Autorzy:
Bigolas, J.
Drabik, W.
Pławski, E.
Wysocka-Rabin, A.
Powiązania:
https://bibliotekanauki.pl/articles/147478.pdf
Data publikacji:
2006
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
linear accelerator
electron RF accelerator
photon beam
radiography
Opis:
This paper describes the 6 MeV linac electron accelerator facility now operating at SINS, Świerk, Poland. The accelerator can work in both the electron or X-ray photon mode. The photon beam may be used for non-destructive radiographic investigations on a laboratory scale and, with some modifications, for industrial purposes, as well. As the accelerator's removable tungsten e/X converter is placed outside, the beam vacuum window, an external electron beam is also accessible. The design stages of the accelerator's construction are described, and examples of measurements and radiographic pictures are also presented.
Źródło:
Nukleonika; 2006, 51, 2; 131-135
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Digital Radiography (Dr) in an Approach to Evaluate the Technical Condition of MiG-29’s Vertical Stabilizers
Autorzy:
Luziński, Rafał
Synaszko, Piotr
Dragan, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2105179.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
NDT
digital radiography
inspection of internal structures
composite structures
Opis:
The purpose of the work presented was to evaluate the capabilities of digital radiography to detect cracks in the internal structure of MiG-29 vertical stabilizers. The test object was a stabilizer previously subjected to fatigue testing and partially torn down for the needs of visual inspection. An inspection of three regions containing cracked parts was performed, with use of a pulsed x-ray generator and digital detector array. The results confirmed the method could be used to detect cracks in an internal structure which could not be inspected with other methods without affecting the stabilizer’s integrity.
Źródło:
Fatigue of Aircraft Structures; 2021, 13; 1--7
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studies on water transport in quasi two-dimensional porous systems using neutron radiography
Autorzy:
Fijał-Kirejczyk, Izabela M.
Rogante, Massimo
Milczarek, Jacek J.
Żołądek-Nowak, Joanna
Jurkowski, Zdzisław
Żołądek, Jan
Rusinek, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2105332.pdf
Data publikacji:
2022
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
water transport
drying
fractal
neutron radiography
wettability
wicking
wetting
Opis:
The spontaneous wetting and drying of flat porous samples of linen, cotton and synthetic textiles were studied using dynamic neutron radiography (DNR). The progress of the wetting process of the media was delineated from the obtained neutron dynamical radiography images. The results of the investigation reveal a non-classical behaviour of kinetics of wicking of these materials. The character of the wetting kinetics is discussed in terms of the fractal character of the tortuosity of fabric capillaries.
Źródło:
Nukleonika; 2022, 67, 1; 3--9
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory methods for testing the performance of pyrotechnic delay elements
Autorzy:
Warchol, R.
Nita, M.
Powiązania:
https://bibliotekanauki.pl/articles/30146954.pdf
Data publikacji:
2018
Wydawca:
Akademia Wojsk Lądowych imienia generała Tadeusza Kościuszki
Tematy:
pyrotechnic delay element
ammunition
X-ray radiography
thermal imaging
Opis:
Pyrotechnic delay elements owing to their simple structure and reliability are very often used as part of the design of ammunition. Their basic task consists in generating a specified delay between the respective actions of two elements/systems, required to ensure the safe and reliable work of ammunition. The paper presents laboratory methods employed for testing the performance of pyrotechnic delay elements (PDEs) used in means of combat. The introductory part describes pyrotechnical delay elements and the task fulfilled by them in ammunition. The next part discusses performance parameters of pyrotechnic delay elements, decisive for their proper operation, and factors influencing such operation. In its main part the article presents the standard defining the laboratory methods to be employed for testing pyrotechnic delay elements. According to the above-mentioned standard, the laboratory methods of testing pyrotechnic delay elements can be divided into tests in the open and closed systems. Further, the paper discusses both types of test systems. Taking account of a wide thematic scope of the discussed issue, this article focuses mainly on presenting new methods of testing pyrotechnic delay elements, which have not been mentioned in the standard. Provided examples of tests of pyrotechnic delay elements have been taken from the Polish and foreign literature. Two methods of testing pyrotechnic delay elements are worth paying special attention, one making use of a thermal imaging camera, and the other relying on Roentgen radiation.
Źródło:
Scientific Journal of the Military University of Land Forces; 2018, 50, 4(190); 101-115
2544-7122
2545-0719
Pojawia się w:
Scientific Journal of the Military University of Land Forces
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ionising Radiation in Non-Destructive Testing. Part 2 – Selected Issues Related to the Implementation of Radiographic Testing for the Diagnosis of Rail Joints on PKP PLK S.A. Infrastructure
Autorzy:
Ostromęcka, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/28328218.pdf
Data publikacji:
2023
Wydawca:
Instytut Kolejnictwa
Tematy:
non-destructive testing
industrial radiography
welded joint
rail joints
Opis:
The article presents the main issues and challenges associated with the implementation of radiographic testing for the diagnosis of rail joints conducted in field conditions on the infrastructure of PKP PLK. It outlines the range of guidelines that need to be created or modified in relation to the necessity of using ionising radiation, and identifies possible areas for reducing the time taken to perform the tests.
Źródło:
Problemy Kolejnictwa; 2023, 199; 87--95
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic segmentation of radiographic images in industrial applications
Autorzy:
Baniukiewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/140390.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
radiografia
rozpoznawanie wad
przetwarzanie obrazów
radiography
nondestructive testing
image processing
Opis:
A technology that utilizes penetrating rays is one of the oldest nondestructive testing methods. Nowadays, the process of radiogram analysis is performed by qualified human operators and automatic systems are still under development. In this work we present advanced algorithms for automatic segmentation of radiographic images of welded joints. The goal of segmentation of a radiogram is to change and simplify representation of the image into a form that is more meaningful and easier to analyse automatically. The radiogram is divided into parts containing the weld line, image quality indicators, lead characters, and possible defects. Then, each part is analysed separately by specialized algorithms within the framework of the Intelligent System for Radiogram Analysis.
Źródło:
Archives of Electrical Engineering; 2011, 60, 3; 349-356
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiologia w studiu projektowym
Radiology in a design studio
Autorzy:
Nawara, A.
Kamisińska-Bosiak, A.
Urbanik, A.
Powiązania:
https://bibliotekanauki.pl/articles/112250.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
radiografia
studio projektowe
opakowanie
reklama
radiography
design studio
package
advertisement
Opis:
Artykuł przedstawia przykład współpracy pomiędzy zakładem radiologii a studiem projektowym przy opracowaniu projektu opakowań serii kosmetyków. Zrealizowano pomysł, aby dla marki, która oferuje produkty pielęgnacyjne o wysokiej zawartości składników pochodzenia naturalnego, ilustracje lub fotografie na opakowaniach zastąpić rentenogramami roślin.
The article presents an example of cooperation between a radiology department and a design studio when developing a cosmetics series packaging project. The idea was realized that for a brand that offers beauty products with a high content of natural ingredients, illustrations or photographs on packaging, replace with X-Ray images of the plants.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 3; 141-143
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór liczby naświetlań w badaniach radiograficznych
Selection of the number of radiographs in radiographic examinations
Autorzy:
Opas, A.
Pakos, R.
Powiązania:
https://bibliotekanauki.pl/articles/107770.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
radiography
radiogram quality
dispersion radiation
badania radiograficzne
jakość radiogramu
promieniowanie rozproszone
Opis:
The article defines the importance of analyzing the number of radiographs performed in radiographic studies depending on the geometrical properties of the object and the accepted test method. Considerations were based on the minimum exposure data for one- and two-wall penetration techniques as defined in PN-ISO EN 17636-1 for pipes with a diameter of less than or greater than 100 mm. The rules for selecting the number of exposures were determined.
W artykule tym określono znaczenie analizy liczby wykonanych radiogramów w badaniach radiograficznych w zależności od właściwości geometrycznych obiektu i przyjętej metody badań. Rozważania przeprowadzono w oparciu o dane dotyczące minimalnej ilości ekspozycji w technikach penetracji jednej i dwóch ścianek zawartych w normie PN- ISO EN 17636-1 dla rur o średnicy mniejszej i przekraczającej 100 mm. Określono zasady doboru liczby ekspozycji.
Źródło:
Badania Nieniszczące i Diagnostyka; 2017, 1-2; 31-34
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and performance of a system for two - dimensional readout of gas electron multiplier detectors for proton range radiography
Autorzy:
Wiącek, P.
Dąbrowski, W.
Fiutowski, T.
Mindur, B.
Zielińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/146722.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
front-end electronics
GEM detectors
2-D imaging
proton range radiography
Opis:
The proton range radiography (PRR) technique being developed is expected to provide significant improvements in precision delivery of the therapeutic dose in the hadron therapy. The technique requires measuring residual energies and trajectories of mono-energetic protons passing through an object to be imaged. Such an imaging system can be operated in-situ before and after the treatment allowing real time monitoring of the irradiated tissue position. A detector system suitable for such applications must be capable of measuring proton tracks with submillimeter spatial resolution over area of 30 x 30 cm2. In order to limit the exposure time and obtain real-time images the detector and data acquisition must provide capability of measuring high proton rates up to 106 s-1. In this paper we present novel concept of two-dimensional (2-D) readout of the gas electron multiplier (GEM) detectors used as the position sensitive detectors. The key component of the system is an application specific integrated circuit (ASIC) named GEMROC. The GEMROC comprises 32 independent channels, each one capable of measuring the amplitude and the time of incoming signals. The positions are then reconstructed by coincidences of signals from the X- and Y-readout strips. The design and performance of the GEMROC ASIC are discussed and the results obtained for a test bench based on a smaller 10 x 10 cm2 GEM chamber are presented. The test results demonstrate clearly that with respect to the two critical parameters, i.e. the noise and the count rate capability, the developed readout system meets the requirements for clinical applications of the PRR technique.
Źródło:
Nukleonika; 2012, 57, 4; 513-519
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X pinch as a source for X-ray radiography
Autorzy:
Pikuz, S.
Shelkovenko, T.
Romanova, V.
Sinars, D.
Hammer, D.
Bland, S.
Lebedev, S.
Powiązania:
https://bibliotekanauki.pl/articles/147532.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
wire array
X-pinch
X-ray imaging
X-ray radiography
Z-pinch
Opis:
This article describes several applications and methods using the X pinch as a source of X-ray radiation for the radiography of dense plasma objects. These methods, in general, do not use pinholes, and instead take the advantage of the small size (<1 mm, and in some cases <3 mm) and a short X-ray emission duration (<1 ns) of the radiation source produced by an X pinch. Two of these methods, monochromatic and direct point-projection backlighting, are discussed. Experimental images of exploding wires and wire arrays obtained on the BIN, XP, and MAGPIE generators using these techniques are presented. Also included are detailed measurements made on the XP generator of the emission characteristics of X pinches using different wire materials.
Źródło:
Nukleonika; 2001, 46, 1; 21-25
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Industrial X-ray testing without intermediate data carriers of information
Przemysłowe badanie rentgenowskie bez pośrednich nośników informacji
Autorzy:
Troitskiy, V.
Powiązania:
https://bibliotekanauki.pl/articles/107722.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
film radiography
flash-radiography
digital image
scintillator
solid-state transducer
X-ray mini technology
radiografia błonowa
radiografia błyskowa
obraz cyfrowy
scyntylator
przetwornik półprzewodnikowy
technologia przenośnych urządzeń X-ray
Opis:
The new direction of radiography is Flash-radiography (FR ) which doesn’t have intermediate data carriers (films and storage plates). FR produces a quick image. It provides low testing cost, and capability of multi-angle real time internal defects monitoring of the objects. In film radiography, if relative photometric density is more than 4, then the snapshots become virtually unreadable and they can be difficult to be digitized. Current film-free technologies do not have this disadvantage and, besides, give results in a digital form without special digitizing systems. Digital data contain radiation images of internal defects, expand the flawdetection possibilities and reduce testing cost. Flash-radiography is based on portable X-ray television, which allows the observation of X-ray testing results on a monitor screen. The internal defects examination from different angles may be carried out. Flash-radiography with digital solid-state transducers is the most perspective one with sensitivity up to 0.1% of examined metal’s thickness at resolution exceeding 10 pairs of lines per mm. Application of small-size movable solid-state transducers opens new technological capabilities. They can be located and moved in the zones where positioning of film holders and storage plates is impossible. The new X-ray mini technology expands the application of NDT. The examples of practical application of solid-state miniature transducers are presented.
Nowym kierunkiem radiografii jest radiografia błyskowa (ang. flash radiograpy, FR), która nie ma pośrednich nośników danych (błon i płyt pamięciowych). FR tworzy szybki obraz. Zapewnia niskie koszty testowania oraz możliwość monitorowania obiektów pod kątem błędów wewnętrznych w czasie rzeczywistym. W radiografii błonowej, jeśli względna gęstość fotometryczna jest większa niż 4, migawki stają się praktycznie nieczytelne i mogą być trudne do digitalizacji. Obecne technologie wolne od błon radiograficznych nie mają tej wady, a poza tym dają wyniki w formie cyfrowej bez specjalnych systemów do digitalizacji. Dane cyfrowe zawierają obrazy promieniowania z defektów wewnętrznych, rozszerzają możliwości wykrywania wad i zmniejszają koszty testowania. Promieniowanie błyskowe jest oparte na przenośnym aparacie rentgenowskim, który umożliwia obserwację wyników badań rentgenowskich na ekranie monitora. Można przeprowadzić badanie wad wewnętrznych pod różnymi kątami. Promieniowanie błyskowe z cyfrowymi przetwornikami półprzewodnikowymi jest najbardziej perspektywiczne z czułością na poziomie do 0,1% badanej grubości metalu przy rozdzielczości przekraczającej 10 par linii na mm. Zastosowanie przenośnych przetworników półprzewodnikowych o niewielkich rozmiarach otwiera nowe możliwości technologiczne. Można je lokalizować i przemieszczać w strefach, w których nie jest możliwe pozycjonowanie uchwytów błon i płyt do przechowywania. Nowa mini technologia rentgenowska rozszerza zastosowanie NDT. Przedstawiono przykłady praktycznego zastosowania miniaturowych przetworników półprzewodnikowych.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 2; 29-34
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Steam Formation and Migration in Firefighters’ Protective Clothing Using X-Ray Radiography
Autorzy:
Keiser, C.
Wyss, P.
Rossi, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/89736.pdf
Data publikacji:
2010
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
X-ray radiography
evaporation
steam transfer
protective clothing
firefighting
heat and mass transfer
Opis:
X-ray radiography was used to quantify evaporation and moisture transfer in a multilayer firefighter protective clothing system with defined wetted layers exposed to low thermal radiation. Evaporation was faster and took place at higher temperatures if the moisture was located in the outer layers of the clothing system. Moisture that evaporated in the outer layers of the clothing system was found to move inwards and condense in the inner layers and on the cap of the measurement cell. Results found in this study correlated well with the findings of our former study based on simple temperature distribution measurements to determine moisture transfer in protective clothing layers at low level thermal radiation.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2010, 16, 2; 217-229
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Can laser - driven protons be used as diagnostics in ICF experiments ?
Autorzy:
Volpe, L.
Batani, D.
Powiązania:
https://bibliotekanauki.pl/articles/146375.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
laser-driven protons
inertial confinement fusion (ICF)
proton radiography (PR)
radio-chromic films (RCF)
Opis:
Point projection proton backlighting was recently used to image a cylindrical imploding target at Rutherford Appleton Laboratory (UK). Due to the relatively low energy and to the very large mass densities reached during implosion, protons traveling through the target undergo a very large number of collisions which reduced the resolution. Here, we present a simple analytical model to study the proton radiography (PR) performance as a function of the main experimental parameters. This approach leads to define two different criteria for PR resolution describing different experimental conditions.
Źródło:
Nukleonika; 2012, 57, 2; 231-235
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytm analizy obrazu do diagnostyki połączeń spawanych
Algorithms of image analysis for diagnosis of welded connections
Autorzy:
Rząsa, M.
Sowa-Watrak, A.
Powiązania:
https://bibliotekanauki.pl/articles/267845.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
analiza obrazu
połączenia spawane
radiografia
filtracja RGB
image analysis
welded joints
radiography
RGB filtering
Opis:
W artykule przedstawiono opracowany przez autorów algorytm komputerowej analizy obrazu wspomagający proces diagnostyki połączeń spawanych. Zwrócono uwagę na podstawowe wady, jakie powstają w złączach spawanych oraz na podstawowe utrudnienia w diagnozowaniu tych wad. Przedstawiono komputerową metodę analizy obrazu opartą na progowaniu wartości nasycenia koloru. Metoda może być stosowano do diagnozowania obrazów czarno-białych zapisanych w skali odcieni szarości. Ponadto przedstawiono modyfikację metody polegającą na zapisaniu obrazu czarno-białego w palecie barw RGB, a następnie przeprowadzeniu progowania przy zastosowaniu filtracji RGB. W pracy przedstawiono wyniki przykładowych analiz, ze zwróceniem uwagi na walory zastosowanej metody analizy obrazu. Rozwiązanie to poszerza możliwości obrazowania wykrytych wad materiałowych, co usprawnia klasyfikację złącz spawanych.
This article aims to present an image analysis algorithm for welded diagnostics. It contains information about the welding process and factors affecting its poorly reproducible process. It highlights the essence of welded weld diagnostics, and also lists the most common features of nonconformity. In addition, it illustrates in most cases the methods of diagnosing welds, which include ultrasonic testing or x-ray scans. It then presents the very idea of radiographic research, which consists in the radiographic image of the binarization process. In addition, it presents computer-aided image analysis methods. It also reveals the use of RGB filtration, as evidenced by the numerous illustrations illustrating the double layer weld filtering in both R, B and G color. The article shows that the diagnostic method used improves the classification of welded joints. The use of selective RGB filtering not only enables the filtering of basic RGB colors, but also provides the ability to filter in R-G, R-B and G-R combinations, which will further increase the potential for imaging of material defects found.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 55; 61-64
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wyrobów aerozolowych w Laboratorium Badań Radiograficznych OUM w Warszawie
Testing of aerosols in the Radiographic Research Laboratory at OUM Warsaw
Autorzy:
Sawicki, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1426275.pdf
Data publikacji:
2020
Wydawca:
Główny Urząd Miar
Tematy:
radiografia cyfrowa
promieniowanie jonizujące
wzorcowanie metodą wagową
digital radiography
ionizing radiation
calibration by weight method
Opis:
W artykule przedstawiono powody utworzenia Laboratorium Badań Radiograficznych w Okręgowym Urzędzie Miar w Warszawie. Opisano metodę wyznaczania objętości wyrobów aerozolowych w oparciu o radiografię cyfrową z zastosowaniem promieniowania jonizującego. Zaprezentowano stanowisko pomiarowe wykorzystujące promieniowanie jonizujące oraz stanowisko pomiarowe do wzorcowania pojemników aerozolowych metodą wagową.
The article presents the reasons for the establishing the Radiographic Research Laboratory at the Regional Office of Measures in Warsaw. The method of evaluation the volume of aerosols based on digital radiography with the use of ionizing radiation is described. A measuring system using ionizing radiation and a measuring system for calibration of aerosol cans by weight method are presented.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2020, 2 (25); 55--60
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wczesnośredniowieczne miecze ze zbiorów Muzeum Narodowego w Szczecinie w świetle ponownej analizy typologiczno-chronologicznej i technologicznej (część 2)
Early medieval swords from the collection of the National Museum in Szczecin in the light of a new typological-chronological and technological analysis (part 2)
Autorzy:
Kucypera, Paweł
Kurasiński, Piotr
Pudło, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/440653.pdf
Data publikacji:
2013
Wydawca:
Muzeum Narodowe w Szczecinie
Tematy:
miecze
wczesne średniowiecze
Pomorze Zachodnie
klasyfikacja
radiografia
swords
Early Middle Ages
Western Pomerania
classification
radiography
Opis:
This study is devoted to four early medieval swords stored in the National Museum in Szczecin. The paper is a continuation of the weapon collection from the Szczecin Museum presentation, with first part published recently (Klimek, Kucypera, Kurasiński, Pudło 2011). All swords presented here were posted before, but, thus far, bereft of detailed formal, chronological and technological analyzes. The oldest presented specimen was found in Smołdzino, Słupsk District. No detailed location of the find is known, apart from the fact that it was uncovered by sand from a dune. It is preserved as a few pieces coming from a broken blade. Another two swords were also preserved partially, both with almost completely missing blades. They are most probably stray finds from the River Oder near Szczecin. The last, youngest specimen, is a loose find from Złocieniec, Drawsko District. The Smołdzino sword has been dated to the 2nd half of the 8th–half of the 10th centuries, however, it has to be noted that the technique in which its blade was forged (piled/sandwitched) does not allow to completely rule out the possibility of the sword’s earlier (La Tène period) metric. First of the Oder (Szczecin) swords has been classified as the younger type X by Petersen and dated to the 10th–half of the 11th centuries. The second specimen has been identified as Oakeshott’s type ?,B,3 and Geibig’s Kombinationstyp 15-III. It has been linked with the period of the 10th–beginning of the 12th centuries. Both specimens picked from the Oder River had blades forged by welding cutting-edge rods into central core pieces. Their lower guards and pommels (with, possibly, one exception) were formed from single homogeneous billets of iron. By far, the best preserved sword was the one from Złocieniec, classified here as type XI,E,1 by Oakeshott and Kombinationstyp 19 (hilt) and 10 (blade) by Geibig. In view of the presented analogies, it has been fixed to the chronological frame of the 12th–beginning of the 13th century. Unfortunately, due to external factors, no materials examination has been carried out on this weapon.
Źródło:
Materiały Zachodniopomorskie; 2012, 9; 269-296
0076-5236
Pojawia się w:
Materiały Zachodniopomorskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wybranych systemów obrazowania cyfrowego w mammografii
Comparison of chosen digital imaging systems in mammography
Autorzy:
Jakubowska, T.
Powiązania:
https://bibliotekanauki.pl/articles/262184.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
mammografia cyfrowa
obrazowanie cyfrowe
DR
CR
digital mammography
digital imaging
dynamic replacement (DR)
computed radiography (CR)
Opis:
Mammografia jest najbardziej czułym i specyficznym badaniem w diagnozowaniu raka sutka. Zastosowanie techniki cyfrowej CR (Computed Radiography) i DR (Digital Radiography) ma na celu poprawę jakości obrazów, a co za tym idzie poprawę wykrywalności zmian przy jednoczesnym skróceniu czasu badania i obniżeniu dawki promieniowania. Niniejsza praca przedstawia porównanie stosowanych obecnie w mammografii wybranych systemów cyfrowych pod względem jakości obrazowania, jak również stosowanych dawek.
Mammography is a most sensitive and specific examination used in the breast cancer diagnosis. Digital radiographic systems CR (Computed Radiography) and DR (Digital Radiography) offer the high quality imaging with shorter exposure times, thus lowering the radiation dose. In this paper, the comparison of frequently used mammographic digital systems in terms of the imaging quality and doses applied, is presented.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2012, 18, 4; 260-266
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy opatrunek gipsowy wpływa na indeks ekspozycji i dose area product? : Odpowiedź na przykładzie radiografii nadgarstka
Are the plaster cast have influence on exposure index and dose area product value? : Based on the wrist radiography
Autorzy:
Nowak, P.
Murzyn, K.
Pasieka, E.
Powiązania:
https://bibliotekanauki.pl/articles/112147.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
indeks ekspozycji
nadgarstek
zdjęcie rentgenowskie
opatrunek gipsowy
dose area product
exposure index, wrist
radiography
plaster cast
Opis:
Złamania dystalnej części kości promieniowej należą do jednych z najczęstszych urazów kości. W przypadku tego typu urazów podstawnym badaniem obrazowym, ze względu na niski koszt wykonania i ogólną dostępność, jest zdjęcie rentgenowskie. Standardowo radiografię stawu nadgarstkowego wykonuje się w projekcji: tylno-przedniej, skośnej i bocznej. Dodatkowymi badaniami są radiogramy w odchyleniu promieniowym lub łokciowym, a także zdjęcie celowane na kanał nadgarstka oraz kość łódeczkowatą. Cel: Celem pracy była retrospektywna analiza wartości dose area product i indeksu ekspozycji podczas radiografii stawu nadgarstkowego u pacjentów z zastosowanym opatrunkiem gipsowym oraz bez, w zależności od wielkości pola kolimacji rentgenogramu, a także wykorzystanych do diagnostyki parametrów ekspozycji. Materiały i metody: Analizie retrospektywnej poddano 208 losowo wybranych radiogramów stawu nadgarstkowego wykonanych w Zakładzie Radiologii Uniwersyteckiego Szpitala Klinicznego w Białymstoku aparatem RTG Axiom Aristos firmy Siemens. Badanie obejmowało wartości dose area product i indeksu ekspozycji, napięcia anodowego, obciążenia prądowo-czasowego oraz wiel¬kości pól kolimacji. Zebrane dane poddano analizie statystycznej przy użyciu programu Statistica 12,5 oraz MS Excel 2013. Wyniki: Większą część osób, którym wykonano radiogramy, sta¬nowiły kobiety. W tej grupie średnia wieku wyniosła 63,79 lat, natomiast średnia wieku mężczyzn była równa 47,56 lat. Średnia wielkość pola kolimacji rentgenogramu z grupy objętej bada¬niem wyniosła 324,17 cm2. Przy założeniu, że wartość referen¬cyjna pola kolimacji wynosi 234 cm2 (13 x 18 cm), to 160 (72,92%) zdjęć miało pole kolimacji większe od wartości referencyjnej, natomiast przy przyjęciu 432 cm2 (18 x 24 cm) jako wartość odniesienia tylko 35 (16,83%) radiogramów było większych od wartości wzorcowej. Wartość współczynnika ekspozycji wynio¬sła średnio 645,87 z wartością maksymalną równą 2980,00, na¬tomiast najniższa wartość była równa 141,00. Średnia wartość DAP w grupie objętej badaniem wyniosła 0,02 Gy∙cm2, przy od¬chyleniu standardowym 0,01 Gy∙cm2. Największa odnotowana wartość współczynnika DAP wyniosła 0,07 Gy∙cm2, natomiast najmniejsza 0,01 Gy∙cm2. Testy statystyczne wykazały korelację między polem powierzchni a DAP na poziomie rs = 0,78 i polem powierzchni a EXI rs = 0,19 oraz między wartością DAP (p = 0,00) i EXI (p = 0,00) a obecnością opatrunku gipsowego. Wnioski: W radiografii cyfrowej bezpośredniej (system Siemens) opatrunek gipsowy wpływa w istotny sposób na wartości DAP, zwiększając go średnio o 0,01 Gy∙cm2 oraz EXI, zmniejszając jego wartość niemal o połowę. Także zwiększenie pola kolimacji po¬woduje zwiększenie wartości DAP i EXI w radiografii nadgarstka.
Distal part radial bone fractures are one of the most common types of trauma. The basis of imaging examination of the injury is radiography. The advantages of the X-ray examination are low costs and widespread availability. Standard projections for the wrist are posteroanterior and lateral views. However, there are many ancillary views like a radiograms obtained with radial or ulnar deviation and carpal tunel. Aim: The aim of the study is retrospective analysis of dose area product and exposure index during radiography of the wrist. The analysis included value collimation size and exposure para¬meters depending on whether plaster immobilization was used or not. Materials and methods: We conduct retrospective analysis of randomly selected 208 radiographs of the wrist. X-ray photos were taken of patients at the Department of Radiology, Medi¬cal University Hospital in Bialystok, with Axiom Aristos Siemens. The analysis included value of the dose area product, exposure index, tube potential, tube current-time product and collima¬tion field. Statistical analysis was done using Statistica 12.5 and MS Excel 2013. Results: The most frequently radiographs were taken for wo¬men which average age was 63,79 while average age for men was 47,56. The average size of X-ray was 324,17 cm2. Assuming that the reference value of the collimation field is 234 cm2 (160x160), 160 (72.92%) images had collimation field greater than reference value. On the other hand when reference va¬lue is 432 cm2 (18 x 24 cm) only 35 (16.83%) of the radiographs were greater. The average exposure index value was 645,87, while the maximum value was 2980,00 and minimum value was 141,00. The average DAP in study group was 0,02 Gy∙cm2, SD = 0,01 Gy∙cm2. The largest recorded DAP was 0,07 Gy∙cm2, while the smallest was 0,01 Gy∙cm2. Statistic tests showed a signifi¬cant dependence between collimation field size value and DAP (rs = 0 ,78), c ollimation fi eld s ize v alue a nd E XI ( rs = 0 ,19); D AP (p = 0,00) and EXI (p = 0,00), and presence of plaster cast. Conclusions: In digital radiology (Siemens), plaster cast have a si¬gnificant influence on DAP, increasing it 0,01 Gy∙cm2 on average and EXI reduced its value almost by half. The increased surface area of the radiographs causes increased DAP and EXI.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 2; 85-91
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of radiography for measurements of the medullary cavity in the metacarpal bone in the European roe deer Capreolus capreolus for assessment of ontogenetic quality - preliminary study
Autorzy:
Czyzowski, P.
Okrasa, A.
Beeger, S.
Karpinski, M.
Powiązania:
https://bibliotekanauki.pl/articles/2119507.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Zootechniczne
Tematy:
roe deer
Capreolus capreolus
radiography
metacarpal bone
kidney fat index
medullary cavity
individual quality
carcass weight
Opis:
The objective of the study was to test the research hypothesis that the surface area of the medullary bone is correlated with other indicators of body condition. The study also focused on identification of potential differences in and with carcass weight fat parameters and carcass weight between forest and field ecotypes of roe deer. The area of the medullary cavity was measured using DIRA 200 software. Metacarpal bone III+IV, proximal phalanges III and IV, and middle phalanges III and IV were measured as well. The study included 38 female European roe deer (Capreolus capreolus) aged 3-5 years. The results revealed a statistically significant negative correlation between the surface area of the medullary cavity in metacarpal bone III+IV and the kidney fat index KFI (rs = −0,483; P < 0,05) and the weight of the perirenal adipose tissue (rs = −0,362; P < 0,05). No correlation was shown between the area of the medullary cavity of metacarpal bone III+IV and the doe carcass weight (rs = 0,093; ns). The size of the medullary cavity is an anatomical parameter that is not susceptible to cyclical changes in environmental conditions. The study showed that it is independent of body weight and determines the amount of bone marrow and hence the amount of accumulated fat reserves. We believe that, alongside biometric measurements, the surface area of the medullary cavity can be a good parameter for assessment of the individual quality of roe deer and for comparison of populations.
Źródło:
Roczniki Naukowe Polskiego Towarzystwa Zootechnicznego; 2021, 17, 4; 17-24
1733-7305
Pojawia się w:
Roczniki Naukowe Polskiego Towarzystwa Zootechnicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostic imaging of psoriatic arthritis. Part I: etiopathogenesis, classifications and radiographic features
Diagnostyka obrazowa łuszczycowego zapalenia stawów. Część I: etiopatogeneza, klasyfikacje i rentgenodiagnostyka
Autorzy:
Sudoł-Szopińska, Iwona
Matuszewska, Genowefa
Kwiatkowska, Brygida
Pracoń, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1052753.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
diagnostic imaging
enthesitis
plain radiography
psoriatic arthritis
spondyloarthritis
diagnostyka obrazowa
radiografia
zapalenie stawów kręgosłupa
łuszczycowe zapalenie stawów
Opis:
Psoriatic arthritis is one of the spondyloarthritis. It is a disease of clinical heterogenicity, which may affect peripheral joints, as well as axial spine, with presence of inflammatory lesions in soft tissue, in a form of dactylitis and enthesopathy. Plain radiography remains the basic imaging modality for PsA diagnosis, although early inflammatory changes affecting soft tissue and bone marrow cannot be detected with its use, or the image is indistinctive. Typical radiographic features of PsA occur in an advanced disease, mainly within the synovial joints, but also in fibrocartilaginous joints, such as sacroiliac joints, and additionally in entheses of tendons and ligaments. Moll and Wright classified PsA into 5 subtypes: asymmetric oligoarthritis, symmetric polyarthritis, arthritis mutilans, distal interphalangeal arthritis of the hands and feet and spinal column involvement. In this part of the paper we discuss radiographic features of the disease. The next one will address magnetic resonance imaging and ultrasonography.
Łuszczycowe zapalenie stawów jest jednostką należącą do grupy zapaleń kręgosłupa z towarzyszącym zapaleniem stawów obwodowych (spondyloarthritis, SpA). Choroba ma różne manifestacje kliniczne – może przebiegać z zajęciem stawów obwodowych, jak również kręgosłupa osiowego oraz z obecnością zmian zapalnych tkanek miękkich, w postaci zapalenia palca (dactylitis) bądź entezopatii. Klasyczna radiografia stanowi metodę z wyboru używaną w diagnostyce łuszczycowego zapalenia stawów, jednak nie uwidacznia ona wczesnych zmian zapalnych tkanek miękkich i szpiku kostnego lub obraz radiograficzny nie jest charakterystyczny. Typowe zmiany radiograficzne ujawniają się w zaawansowanych stadiach choroby; dotyczą głównie stawów maziówkowych, lecz także chrzęstno-włóknistych, takich jak stawy krzyżowo-biodrowe, oraz entez ścięgien i więzadeł. Moll i Wright sklasyfikowali łuszczycowe zapalenie stawów, wyróżniając pięć podtypów choroby: asymetryczne zapalenie nielicznostawowe, symetryczne zapalenie wielostawowe, postać nadżerkową arthritis mutilans, postać zajmującą stawy międzypaliczkowe dalsze palców rąk i stóp oraz zajęcie kręgosłupa osiowego. W pierwszej części artykułu przedstawiono radiograficzne manifestacje choroby. W części drugiej zostaną omówione zmiany widoczne w badaniu metodą rezonansu magnetycznego i w ultrasonografii.
Źródło:
Journal of Ultrasonography; 2016, 16, 64; 65-77
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiografia w ochronie dziedzictwa kulturowego
Radiography in the protection of cultural heritage
Autorzy:
Głuszewski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2171854.pdf
Data publikacji:
2022
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiografia
konserwacja dzieł sztuki
promieniowanie hamowania
fluorescencja rentgenowska
radiography
conservation of works of art
bremsstrahlung
X-ray fluorescence
Opis:
Metody radiograficzne pozwalają za pomocą promieniowań X oraz gamma (γ) wykrywać wewnętrzne niezgodności w całej objętości materiału. W zasadzie nie ma ograniczeń co do rodzaju badanych obiektów. Warunkiem jest jedynie dostęp do dwóch stron napromieniowywanego przedmiotu lub konstrukcji. Alternatywą dla analogowych, błonowych technik radiograficznych jest radiografia cyfrowa. O jakości obrazu i dawce pochłoniętej decyduje technologia przetwarzania promieniowania hamowania na sygnał cyfrowy. Postęp w radiografii stymulowany jest głównie przez zastosowania medyczne i przemysłowe. Z nowych rozwiązań mogą korzystać również konserwatorzy dzieł sztuki. Dużą rolę w upowszechnianiu technik jądrowych w identyfikacji i konserwacji obiektów istotnych dla dziedzictwa kulturowego odgrywa Międzynarodowa Agencja Energii Atomowej (MAEA). W artykule omówiono niektóre aspekty zastosowania radiografii w muzealnictwie dyskutowane w trakcie konferencji MAEA zorganizowanej w Narodowym Muzeum Wojny na Malcie.
Radiographic methods make it possible to detect internal and subsurface imperfections in the entire volume of the material using X and gamma rays (γ). In principle, there are no restrictions as to the type of tested objects. The condition is only access to two sides of the irradiated object or structure. An alternative to analog, film radiography techniques is digital radiography. The quality of the image and the absorbed dose are determined by the technology of converting the braking radiation (bremsstrahlung) into a digital signal. Advances in radiography are mainly driven by medical and industrial applications. The new solutions can also be used by art conservators. The International Atomic Energy Agency (IAEA) plays a major role in the dissemination of nuclear techniques in the identification and conservation of objects significant for cultural heritage. The article discusses some aspects of the use of radiography in museology discussed during the IAEA conference organized at the National War Museum in Malta.
Źródło:
Postępy Techniki Jądrowej; 2022, 4; 31--35
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ISEMIR-IR: A worldwide tool to optimize occupational radiation protection in industrial radiography
ISEMIR-IR: Globalne narzędzie do optymalizacji ochrony przed promieniowaniem na stanowisku pracy w radiografii przemysłowej
Autorzy:
Fu, J.
Dojcanova, L.
Ma, J.
Powiązania:
https://bibliotekanauki.pl/articles/107880.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ISEMIR
occupational radiation protection
Industrial Radiography
NDT
ochrona przed promieniowaniem w ramach czynności zawodowych
radiografia przemysłowa
badania nieniszczące
Opis:
Industrial Radiography is widely used in non-destructive testing (NDT ) in the world. Workers in the sector exposure if incidents happen. The Information System on Occupational Exposure in Medicine, Industry and Research: Industrial Radiography so called ISE MIR-IR was developed by the IAEA as a web-based tool for a regular data collection and analysis of occupational exposure. The system was launched with full function in 2017. It was designed based on the data from an extensive research and results of the worldwide surveys. It assists NDT companies to benchmark their own companies and individual performance against others in the database. NDT companies all around the world are encouraged to participate in the database to enable it to become a worldwide tool for implementing optimization of occupational radiation protection.
Radiografia przemysłowa jest szeroko stosowana w badaniach nieniszczących (NDT ) na świecie. Pracownicy tego sektora w przypadku wystąpienia incydentów mogą być narażeni na niebezpieczeństwo. System Informacji o narażeniu zawodowym w medycynie, przemyśle i badaniach: Radiografia przemysłowa (ang. The Information System on Occupational Exposure in Medicine, Industry and Research: Industrial Radiography) nazwany ISE MIR-IR został opracowany przez IAEA jako internetowe narzędzie do regularnego gromadzenia danych i analizy narażenia zawodowego. System został uruchomiony z pełną funkcjonalnością w 2017 roku. Zaprojektowano go w oparciu o dane pochodzące z obszernych badań i wyników światowych sondaży. Pomaga firmom z branży NDT w porównywaniu własnych i indywidualnych wyników z innymi wynikami w bazie danych. Firmy NDT na całym świecie są zachęcane do uczestnictwa w tworzeniu bazy danych, aby umożliwić jej stanie się światowym narzędziem do wdrażania optymalizacji ochrony przed promieniowaniem zawodowym.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 4; 80-82
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wiedzy pacjentek w wieku rozrodczym na temat narażenia radiacyjnego płodu w rentgenodiagnostyce klasycznej
Assessment of patients’ knowledge in childbearing age on the topic of radiation exposure of the fetus in plain radiography
Autorzy:
Pasieka, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/985954.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
kobiety
wiek rozrodczy
wiedza
płód
ochrona radiologiczna
zdjęcie rentgenowskie
women
childbearing age
knowledge
fetus
radiation protection
plain radiography
Opis:
Dzieci, kobiety w wieku rozrodczym i ciężarne to trzy grupy pacjentów, które wymagają specjalnej uwagi w czasie diagnostyki rentgenowskiej. W pojęciu bezpieczeństwa radiacyjnego u kobiet w wieku rozrodczym uwzględnia się wykluczenie ciąży, ograniczenie ekspozycji na gonady oraz wykonywanie badań planowych w zakresie jamy brzusznej i miednicy w pierwszych dniach cyklu miesiączkowego. Celem pracy jest ocena wiedzy pacjentek w wieku rozrodczym na temat wybranych aspektów narażenia płodu podczas rentgenodiagnostyki klasycznej.
Children, women of childbearing age, and pregnant women are three groups of patients that require special attention during X-ray diagnosis. The concept of radiation safety in women of childbearing age includes the reduction doses of ovaries, the exclusion of pregnancy as well as performing the planned examinations in the abdominal cavity and pelvis in the first days of the menstrual cycle. The aim of the study was to assess the knowledge of female patients of childbearing age about the topic of radiation exposure of the fetus in plane radiography.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 1; 43-49
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in Digital Industrial Radiology. Pt. 2, Computed tomography (CT)
Postępy w cyfrowej radiografii przemysłowej. Cz. 2, Tomografia komputerowa
Autorzy:
Ewert, U.
Fuchs, T.
Powiązania:
https://bibliotekanauki.pl/articles/107921.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
digital radiography
computed tomography
laminography
CFRP
aerospace
automotive
radiografia cyfrowa
tomografia komputerowa
laminografia
kompozyty węglowe
przemysł lotniczy
przemysł motoryzacyjny
Opis:
Part 1: Film Replacement and Backscatter Imaging. The related paper was published in Vol 1-2/2016 of this journal. Part 2: Computed tomography (CT). Applications cover the range from nano-meter to meter scale. New specialized high energy CT devices have been laid out for inspection of large building structures or complete cars before and after crash tests. The scope of typical CT applications changes from flaw detection to dimensional measurement in industry substituting coordinate measurement machines. First applications of at line or in line inspection in production lines of car industry are discussed. CT is applied for a variety of applications, where selected areas as e.g. plant and food research in outlined. Mobile computed tomography is applied for in-service radiographic crack detection and sizing of welded pipes in nuclear power plants and for NDT of large CFRP structures of airplanes. Part 3: Micro Radiography and Micro CT. To be published in this journal.
Podobnie jak w przypadku zakończonego sukcesem wdrożenia fotografii cyfrowej, bardzo istotne zmiany można zaobserwować także w cyfrowej radiologii przemysłowej. Niniejsza praca jest podzielona na 3 części: Część 1: Następca błony radiograficznej i obrazowanie za pomocą rozproszenia wstecznego – publikacja ukazała się w wydaniu Nr1-2/2016 tego czasopisma. Część 2: Tomografia komputerowa (CT). Zastosowania tomografii obejmują obiekty o wielkości od nanometrów do metrów. Nowe dedykowane urządzenia wysokoenergetycznej tomografii komputerowej skonstruowano w celu inspekcji dużych konstrukcji budowlanych czy też całych samochodów przed i po testach zderzeniowych. Cel typowego zastosowania tomografii komputerowej uległ zmianie z detekcji wad na wymiarowanie wyrobów przemysłowych, co spowodowało zastąpienie współrzędnościowych maszyn pomiarowych. W pierwszej kolejności omówiono zastosowanie tomografii komputerowej na liniach produkcyjnych w przemyśle samochodowym. Tomografia komputerowa ma wiele zastosowań, w tym np. badanie roślin i żywności. Przenośne tomografy komputerowe wykorzystywane są do wykrywania defektów i wymiarowania spawanych rur w elektrowniach jądrowych, a także do inspekcji dużych elementów konstrukcji lotniczych wykonanych z kompozytów węglowych. Część 3: Mikroradiografia i mikrotomografia komputerowa.
Źródło:
Badania Nieniszczące i Diagnostyka; 2017, 1-2; 7-14
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czy tak samo oceniamy to, co widzimy? Analiza porównawcza zdjęć stawu skokowego przez techników elektroradiologii i studentów kierunku elektroradiologia
Do we evaluate what we see in the same way? Comparative analysis of ankle joint images by radiology technicians and radiography students
Autorzy:
Żelechowicz, M.
Nowak, P.
Tomaszewska, P.
Wyczółkowska, E.
Pasieka, E.
Chwieśko, J.
Powiązania:
https://bibliotekanauki.pl/articles/112107.pdf
Data publikacji:
2018
Wydawca:
Indygo Zahir Media
Tematy:
rentgenodiagnostyka
zdjęcie rentgenowskie
staw skokowy
uraz
skierowanie
technik elektroradiologii
radiography
X-ray image
ankle joint
trauma
referral
adiology technician
Opis:
Wprowadzenie: Co łączy ze sobą światowe sławy: piłkarza Roberta Lewandowskiego, kolarkę górską Maję Włoszczowską, tenisistkę Urszulę Radwańską, skoczka narciarskiego Kamila Stocha i lekkoatletkę Anitę Włodarczyk? Cała wyżej wymieniona grupa sportowców ma na swoim koncie urazy stawu skokowego, bo urazy tej okolicy dotykają przede wszystkim ludzi aktywnych fizycznie. Cel: Celem pracy była weryfikacja prawidłowości wykonywania zdjęć rentgenowskich stawu skokowego oraz analiza danych zawartych w skierowaniach przez dwie grupy badaczy: techników elektroradiologii i studentów kierunku elektroradiologia. Materiał i metody: Analizie retrospektywnej poddano skierowania i zdjęcia rentgenowskie stawu skokowego wykonane 105 pacjentom w dwóch projekcjach: przednio-tylnej (AP) i bocznej (LAT) w Zakładzie Radiologii Uniwersyteckiego Szpitala Klinicznego w Białymstoku. Ocena została dokonana przez trzech techników elektroradiologii oraz trzech studentów kierunku elektroradiologia. Analizie poddano również wiek i płeć pacjentów oraz rozpoznania. Dane poddano analizie statystycznej przy użyciu programu Statistica 13.1 oraz MS Excel 2010. Wyniki: Spośród 105 radiogramów objętych analizą 58 (55,24%) wykonano kobietom. Wśród radiogramów wykonanych w projekcji bocznej brak było określenia strony badanej pacjenta w 47 (44,76%) przypadkach. W sposób istotny statystycznie różniły się od siebie oceny zakresu (p = 0,01) i poprawności pozycjonowania (p = 0 ,01) radiogramów w ykonanych w projekcji A P. Istnieje istotny statystycznie związek pomiędzy zastosowaniem u pacjenta opatrunku gipsowego a oceną przez techników poprawności projekcji przednio-tylnej stawu skokowego (p = 0,01). W grupie studentów wykazano związek pomiędzy opatrunkiem gipsowym a oceną zakresu radiogramów w projekcji bocznej (p = 0,04) oraz zgodnością projekcji bocznej (p = 0,01). Wnioski: 1. Wykazano różnice w ocenie radiogramów pod kątem zakresu oraz pozycjonowania pomiędzy grupą techników elektroradiologii i studentów. 2. Studenci rzadziej akceptowali zakres w ocenianych zdjęciach szczególnie w projekcji przednio-tylnej. 3. Technicy częściej akceptowali poprawność projekcji przednio-tylnej u pacjentów z opatrunkiem gipsowym.
Introduction: What units the most famous sportsmen in the world? They were all subjected to ankle joint injuries, because this trauma is common among physically active people. Purpose: The main goal of this study was the analysis data in referrals and verification of the correctness of making ankle x-rays, performed by 2 groups of researchers: radiographers and radiography students. Materials and methods: Referrals a nd a nkle x-rays i n 2 projections: anterior-posterior (AP) and lateral (LAT) were retrospectively analysed. Radiograms of 105 patients from Radiology Department in Uniwersytecki Szpital Kliniczny in Białystok were used. Evaluation was performed by 3 radiographers and 3 radiology students. Age and sex of the patients and diagnosis were analysed too. Data were statistically analysed with Statistica 13.1 and MS Excel 2010. Results: 58 from 105 analysed x-rays (55,24%) were made among women. The anatomical side was not indicated on lateral radiographs in 47 cases (44,76%). Statistically significant differences were shown in evaluations of anatomical coverage assessment ( p = 0,01) and correctness of positioning ( p = 0,01) in AP x-rays. A statistically significant association between having a plaster cast and evaluation of correctness making anterior- posterior projection on ankle x-ray was observed (p = 0,01). In students group statistically significant association between having a plaster cast and evaluation of anatomical coverage assessment in lateral x-rays (p = 0,04) and compatibility of lateral projection with the guidelines (p = 0,01) was observed. Conclusions: 1. Statistically significant differences in the assessment of radiographs with regard to anatomical coverage and positioning between a group of radiology technicians and students were shown. 2. Students less frequently accepted range in evaluated images, especially in the anterior-posterior projection. 3. Technicians more often accepted the correctness of anterior- posterior projections in patients with a plaster cast.
Źródło:
Inżynier i Fizyk Medyczny; 2018, 7, 3; 149-154
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quality control test of conventional X-Ray systems in Delta State, South-South, Nigeria
Autorzy:
Ijabor, B. O.
Nzotta, C. C.
Omojola, A. D.
Powiązania:
https://bibliotekanauki.pl/articles/1193452.pdf
Data publikacji:
2021
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Digital Radiography (DR)
Focus to Image Distance (FID)
Half Value Layer (HVL)
Practical Peak Voltage (PPV)
Quality Assurance
Quality Control
Silicon Photodiode
Opis:
The quality assurance (QA) and quality control (QC) programmes of imaging equipment are key ingredients of a quality system. This study is aimed at measuring X-Ray machine parameters and comparing them with the American Association of Physicists in Medicine (AAPM) report No. 74. Also, this study made comparison with similar articles locally and internationally. The study was conducted in 12 X-Ray unit (A-L) located in Delta State. A MagicMax Universal Basic Unit was used alongside an XR Multidetector (silicon photodiode) to measure dose, dose rate, practical peak voltage (PPV), exposure time, current in milliampere (mA) and quantity (Q) in milliampere seconds (mAs). The XR Multidetector was positioned at 100 cm from the focus to image distance (FID) to make most measurements. Six (6) X-Ray units were above 20 years, accounting for 50% of the total X-Ray units used. 30% of X-Ray units > 20 years failed the QC test, which was 2.3 times higher than X-Ray units < 10 and 10-20 years respectively. On the average, 55% pass mark was achieved in the 12 X-Ray units across the state, while 26.11% of the test could not be done due to bad knobs and other challenges. Two (2) X-Ray units with an average age of 3 years, passed all the test. The study showed that many of the X-Ray units were old and certain machine parameters could not be assessed. The study also reveal that most X-Ray specifications manual were either misplaced or missing. Continuing QC programme is highly recommended in the studied areas.
Źródło:
World Scientific News; 2021, 157; 140-153
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie bezzałogowych statków powietrznych w diagnostyce technicznej obiektów budowlanych metodami nieniszczącymi
The use of unmanned aerial vehicles in the technical diagnostics of buildings using non-destructive methods
Autorzy:
Mazurek, A.
Powiązania:
https://bibliotekanauki.pl/articles/107742.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
bezzałogowe statki powietrzne
badania nieniszczące
diagnostyka obiektów budowlanych
badania termowizyjne
validation
reliability of inspection result
digital radiography
digital ultrasonic
automated inspection systems
Opis:
Rozwój technologii spowodował pojawienie się nowych metod diagnostyki obiektów budowlanych z wykorzystaniem obrazów cyfrowych uzyskanych za pomocą bezzałogowych statków powietrznych (BSP). Stosuje się je głównie do obserwacji. Łatwo jest jednak wyposażyć drona w dodatkowe moduły lub oprogramowanie, które zwiększą jego możliwości. Ze względu na nieniszczący i nieinwazyjny charakteru, badania mogą być zakończona bardzo szybko, przy minimalnych wymaganiach dotyczących dostępu. Skala możliwości związanych z użyciem drona sprawia, że może on stanowić niezwykle pomocne narzędzie w branży budowlanej. W artykule omówiono możliwości wykorzystania BSP w diagnostyce nieniszczącej obiektów budowlanych, uwarunkowania formalno- prawne użycia dronów w polskiej przestrzeni powietrznej oraz dokonano przeglądu dostępnych na rynku urządzeń.
The development of technology has caused the emergence of new methods of building objects diagnostics using digital images obtained using unmanned aerial vehicles (BSP). They are mainly used for observation. However, it is easy to equip the drone with additional modules or software that will increase its capabilities. Due to the non-destructive and non-invasive nature, tests can be completed very quickly, with minimal access requirements. The scale of possibilities associated with the use of a drone makes it an extremely helpful tool in the construction industry. The article discusses the possibilities of using BSP in non-destructive diagnostics of building objects, formal and legal conditions for the use of drones in the Polish airspace, and a review of devices available on the market.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 3; 66-69
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zwiększanie wiarygodności badania złączy spawanych rurociągów dla cyfrowych technik radiograficznych oraz ultradźwiękowych
Reliability increase of girth welds inspection in view of digital radiography and ultrasonic techniques
Autorzy:
Śliwowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/107912.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
walidacja
wiarygodność wyniku badania
radiografia cyfrowa
ultradźwięki cyfrowe
systemy badań zautomatyzowanych
validation
reliability of inspection result
digital radiography
digital ultrasonic
automated inspection systems
Opis:
W procedurach walidacji urządzeń, systemów badawczych a także nowych zaawansowanych technicznie cyfrowych technik badawczych (high-tech) dużą wagę przykłada się do powtarzalności i odtwarzalności uzyskiwanego wyniku badania. Prowadzone są badania porównawcze polegające na uwiarygodnianiu wyniku badania: • poprzez wykrywanie i wymiarowanie wad na próbkach referencyjnych z wadami sztucznymi lub naturalnymi o znanym położeniu i kształcie; • powtarzalności wyniku (tzn. uzyskiwania podobnych lub identycznych wyników na tym samym obiekcie, z zachowaniem tych samych parametrów techniki NDT ; • odtwarzalności wyniku (tzn. uzyskiwania podobnych lub identycznych wyników na tym samym obiekcie) wykonywanych: różnymi systemami; różnymi metodami / technikami; poprzez digitalizację wyników analogowych dla ujednolicenia porównań; • podwyższaniu powtarzalności wyniku przez automatyzację skanowania. W celu ilustracji procesu uzyskiwania wyników cyfrowych (radiogramów w metodzie radiograficznej zautomatyzowanej - RTA oraz sonogramów w metodzie ultradźwiękowej zautomatyzowanej - UTA ) przedstawiono przykładowe wyniki badań obwodowych złączy spawanych gazociągu DN 1000 oraz DN 800, gdzie wymagania kontraktowe narzucają poziom jakości złączy spawanych B lub wyższy wg PN-EN ISO 5817. Dla celów porównań wykorzystano wyniki standardowych badań radiograficznych na błonach analogowych oraz radiogramy cyfrowe z digitalizacji tych radiogramów analogowych. W aspekcie cyfrowych badań ultradźwiękowych referacie zwrócono uwagę w szczególności na porównania wyników uzyskiwanych techniką TO - FD+PE w konfrontacji z wynikami badania radiograficznego i ręcznych badań ultradźwiękowych. Zwrócono uwagę na ważny aspekt komplementarności wyników radiografii i ultradźwięków dla tego samego złącza i tym samym podwyższania wiarygodności wyniku badania.
In validation procedures of equipment’s, inspection systems as well as technically advanced digital inspection techniques (high-tech) a lot weight be attached to the repeatability and regeneration of testing result to be obtained. The performed results comparison aimed to reach increased reliability of testing by: detection and sizing of imperfections • on reference blocks with implemented discontinuities (natural or prepared) of known localization and shape; • finding repeatability (i.e. the identical or similar results detected on the same object by the same parameters of NDT technique applied); • finding regeneration (i.e. the identical or similar results detected on the same object) obtained by: different inspection systems; different NDT methods/techniques; by digitization of analogue results to unify the comparisons; • finding repeatability increasing by automatization/ mechanizing of testing process. For illustration the digital and mechanized radiographic technique RTA (digital radiographs) and ultrasonic mechanized technique – UTA (digital sonogram TO FD+PE) are presented, as an example of girth welds inspection on pipelines DN 1000 and DN 800. The comparison process was realized using analogue and digitized radiographs versus digital radiographs from DR system. The ultrasonic results of TO FD+PE technique be evaluated in respect of radiography or manual ultrasonic results. It was pointed a complementary aspect of both volumetric methods (RTA and UTA ) and its influence on the increasing reliability of inspection result.
Źródło:
Badania Nieniszczące i Diagnostyka; 2018, 3; 56-65
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Retrospektywna analiza wybranych parametrów jakości radiografii kręgosłupa w odcinku lędźwiowo-krzyżowym
Retrospective analysis of selected quality parameters lumbar-sacral spine radiography
Autorzy:
Pasieka, Ewa
Nowak, Piotr
Martonik, Diana
Powiązania:
https://bibliotekanauki.pl/articles/985951.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
radiografia
kręgosłup lędźwiowo-krzyżowy
promień centralny
kolimacja
automatyczna kontrola ekspozycji
pacjent
jakość
radiography
lumbosacral spine
central radius
collimation
automatic exposure control
patient
preparation
quality
Opis:
Wprowadzenie: Radiografia kręgosłupa w odcinku lędźwiowo-krzyżowym (RTG LS) należy do najczęściej wykonywanych procedur diagnostyki obrazowej. W 2010 roku współczynnik częstości na 1000 mieszkańców Unii Europejskiej wynosił 40,6. Cel: Celem pracy była retrospektywna analiza parametrów jakości radiografii kręgosłupa w odcinku lędźwiowo-krzyżowym. Materiały i metodyka: Analizie retrospektywnej poddano 420 losowo wybranych zdjęć kręgosłupa lędźwiowo-krzyżowego (210 w projekcji przednio-tylnej, AP oraz 210 w projekcji bocznej, LAT). Analiza obejmowała: miejsce padania promienia centralnego, zakres badania, symetrię radiogramu, fazę oddechową, w jakiej wykonano radiografię boczną, poprawność pozycjonowania względem komory automatyki ekspozycji, częstość stosowania lateralizacji oraz przygotowanie pacjenta. Za punkt padania promienia centralnego przyjęto miejsce przecięcia przekątnych radiogramu. Ocenę zakresu badania wykonano, porównując z zakresem anatomicznym opisanym w procedurze wzorcowej. Zebrane dane poddano analizie statystycznej przy użyciu programu Statistica 13.3 przy zastosowaniu poziomu istotności p = 0,05. Wyniki: Promień centralny najczęściej (58; 27,62%) na zdjęciach AP padał na środową część czwartego kręgu lędźwiowego, natomiast na zdjęciach bocznych (53; 25,24%) na trzon trzeciego kręgu lędźwiowego. Na zaledwie 15 (7,14%) radiogramach obszar objęty badaniem był zgodny z opisanym w procedurze wzorcowej. Symetrią pozycjonowania pacjenta w zakresie zachowania płaszczyzny strzałkowej i czołowej charakteryzowało się 120 (57,14%) zdjęć AP, natomiast zachowaniem symetrii w linii pośrodkowej 102 (48,57%) rentgenogramów. W znaczącej większość radiografii (198; 94,29%) przednio-tylnych system automatyki ekspozycji został wykorzystany poprawnie. Natomiast w przypadku projekcji bocznych odsetek zdjęć z prawidłowym pozycjonowaniem względem komory automatyki ekspozycji był niższy (116; 55,24%). Większość (120; 57,14%) zdjęć bocznych wykonanych zostało na wydechu, 74 (35,24%) na wdechu, a w przypadku 30 (14,29%) radiogramu ocena fazy oddechowej nie była możliwa. Określenie strony badanej pacjenta znalazło się na 208 (99,05%) zdjęć przednio-tylnych oraz 62 (29,59%) bocznych. Przygotowanie pacjenta do badania ocenione zostało jako poprawne w przypadku 4 (1,90%) zdjęć AP oraz 24 (11,43%) radiogramów bocznych. Projekcja radiogramów wpływała w istotny statystycznie sposób na częstość oceny przygotowania pacjenta za poprawny (p < 0,001). Wnioski: Ocena miejsca padania promienia centralnego wiązki promieniowania i obszaru objętego badaniem są cennymi czynnikami oceny jakości radiogramów. Analiza materiału własnego wskazuje na konieczność ciągłego doskonalenia z zakresu pozycjonowania pacjenta.
Introduction: Radiography of the lumbosacral spine is one of the most frequently performed diagnostic imaging procedures. In 2010, the frequency ratio per 1000 inhabitants of the European Union was 40,6. Aim: The aim of the study was a retrospective analysis of the quality parameters of the spine radiography in the lumbosacral segment. Material and methods: 420 randomly selected X-rays of the lumbosacral spine (210 in anterior-posterior projection and 210 in lateral projection) were retrospectively analyzed. Included in the analysis was: the place of central radius incidence, the scope of the examination, symmetry of the radiograph, the respiration phase in which the lateral radiography was performed, correctness of positioning relative to the automatic exposure control chamber, frequency of lateralization and patient preparation. The intersection of the radiographs was taken as the point of incidence of the central ray. The assessment of the scope of the examination was made by comparison with the anatomical scope described in the reference procedure. The collected data was subjected to statistical analysis using Statistica 13.3 with the significance level p = 0,05. Results: In the AP X-rays the central ray most often (58; 27,62%) was directed on the middle part of the fourth lumbar vertebra, while on the lateral views it was most often (53; 25,24%) directed on the body of the third lumbar vertebra. The area covered by the examination was consisted with that described in the reference procedure only on 15 (7,14%) radiographs. The symmetry of patient positioning in terms of maintaining the sagittal and frontal planes was described in 120 (57,14%) AP images, while maintaining symmetry of the median line was described in 102 (48,57%) of the radiographs. In the vast majority of the anteroposterior radiographs (198; 94,29%) automatic exposure control system was used correctly. However, in lateral views the percentage of X-rays with correct positioning relative to the automatic exposure chamber was lower (116; 55,24%). The majority (120; 57,14%) of the lateral views were taken with exhalation, 74 (35.24%) with inspiration, and in case of 30 (14,29%) radiographs respiratory phase assessment was not possible. Lateralization was present in 208 (99,05%) anteroposterior views and in 62 (29,59%) lateral views. Patient preparation for the examination was assessed as correct for 4 (1,90%) AP radiographs and 24 (11,43%) lateral radiographs. Radiographic projection had a statistically significant effect on the frequency of assessing patient preparation as correct (p < 0,001). Conclusions: The evaluation of the place of central radius incidence and the area covered by the exam are valuable factors in the quality assessment of radiographs. The analysis of our own material indicates the need for continuous improvement in patient positioning.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 5; 391-398
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Własności mechaniczne stali 13CrMo4-5
Mechanical properties of steel 13CrMo4-5
Autorzy:
Rokosz, K.
Rzadkiewicz, S.
Hryniewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/315100.pdf
Data publikacji:
2014
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
stal 13CrMo4-5
badania wytrzymałościowe
próba rozciągania
próba zginania
metalografia
odporność korozyjna
radiografia
stainless steel 13CrMo4-5
strength tests
tensile test
bending test
metallography
corrosion resistance
radiography
Opis:
W pracy zaprezentowano wyniki badań stali 13CrMo4-5 ze względu na własności mechaniczne. Badany materiał jest najczęściej używany do produkcji wysokociśnieniowych rurociągów parowych w elektrociepłowniach. Do badań użyto rury ze stali 13CrMo4-5 o średnicy 159 mm i grubości 14,2 mm. Wykonano próby rozciągania, zginania, badania twardości, mikrostruktury oraz składu chemicznego. Naprężenie graniczne w próbie rozciągania wyniosło średnio 452 MPa. Próbki zostały poddane zginaniu o kącie gięcia 180°. Zmierzona twardość dla wyżej wymienionej stali wyniosła 147 ± 7,67 HV10. Badania mikrostruktury wykazały ferrytyczno-bainityczną strukturę materiału. Artykuł obrazuje badania, które można wykorzystać do kontroli jakości nowo wykonanych wyrobów, celem eliminacji produktów niespełniających wymagań określonych normą przedmiotową lub wymagań wykonania odbioru WUDT.
The article presents the research results of steel 13CrMo4-5 due to the mechanical and chemical properties. The tested material is mostly used to produce high pressure steam pipelines in heat and power plants. The studies were performed on 13CrMo4 steel pipe with a diameter of 159 mm and a thickness of 14.2 mm. There were performed following analyses: the tensile test, flexural bending, test of hardness, microstructure examination and chemical composition. The average of the stress limit in a tensile test is 452 MPa. The samples were undergone flexural bending angle of 180°. The hardness measured for the above-mentioned steel was 147 ± 7.67 HV10. The studies have shown the microstructure of the material as ferritic-bainitic structure. Article illustrates the research that can be used for quality control of newly made products as well as in avoidance of products which do not fulfill the standards.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2014, 15, 6; 235-239
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Progress in digital industrial radiology. Pt. 1, Radiographic techniques – film replacement and backscatter imaging
Postępy w cyfrowej radiologii przemysłowej. Cz. 1, Techniki radiograficzne - sukcesor błony i obrazowanie rozproszone wstecznie
Autorzy:
Ewert, U.
Powiązania:
https://bibliotekanauki.pl/articles/107864.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
digital radiography
computed tomography
laminography
imaging plates
digital detector arrays
photon counting detectors
back scatter
numeric modelling
CFRP
welding
corrosion
radiografia cyfrowa
tomografia komputerowa
laminografia
płyty obrazowe
cyfrowe detektory radiograficzne
detektory zliczające fotony
rozpraszanie wsteczne
modelowanie numeryczne
spawanie
korozja
Opis:
Similar to the success story of digital photography a major upheaval has been observed in digital industrial radiology. This paper is split into 3 parts: Part 1: Film Replacement and Backscatter Imaging: Computed radiography with phosphor imaging plates substitutes film applications. Digital Detector Arrays enable an extraordinary increase of contrast sensitivity in comparison to film radiography. The increased sensitivity of digital detectors enables the efficient usage for dimensional measurements and functionality tests substituting manual maintenance. The digital measurement of wall thickness and corrosion status is state of the art in petrochemical industry. Photon counting and energy discriminating detectors are applied up to 300 kV and provide increased thickness dynamic and material discrimination by synchronously acquisition of images of the high and low energy part of the spectrum. X-ray back scatter techniques have been applied in safety and security relevant applications with single sided access of source and detector. First inspections of CFRP in aerospace industry were successfully conducted with newly designed back scatter cameras. Numeric modeling is used to design X-Ray optics and inspection scenarios as well as conducting RT training. Part 2: Computed tomography (CT) Part 3: Micro Radiography and Micro CT.
Podobnie jak w przypadku fotografii cyfrowej tak i w cyfrowej radiografii przemysłowej nastąpiły poważne zmiany. Publikacja składa się z 3 części. Część 1.: Zastąpienie techniki analogowej i obrazowanie metodą rozproszenia wstecznego. Radiografia komputerowa z zastosowaniem ekranów luminoforowych (płyt obrazowych) zastępuje błony. Cyfrowe detektory radiograficzne DDA umożliwiają uzyskanie ponadprzeciętnego wzrostu czułości kontrastowej w stosunku do błony. Zwiększona czułość detektorów cyfrowych umożliwia wykorzystanie radiografii do określenia rozmiarów obiektów i przeprowadzenia testów funkcjonalnych, zastępując obsługę ręczną. Pomiar cyfrowy grubości ścianki i procesu korozji rozwinął się znacząco w przemyśle petrochemicznym. Detektory działające w trybie zliczania fotonów z dyskryminacją energetyczną, stosowane do 300 kV umożliwiają większą, dynamiczną rozróżnialność grubości i rodzaju materiału (akwizycja synchroniczna). Techniki związane z rozpraszaniem wstecznym promieniowania X zostały zastosowane w aplikacjach z dziedziny bezpieczeństwa i ochrony, w których źródło i detektor musiały znajdować się po tej samej stronie. Omawiane systemy obrazowania zostały również po raz pierwszy zastosowane do testowania kompozytów węglowych w przemyśle lotniczym. Modelowanie numeryczne zjawisk fizycznych związanych z radiografią jest wykorzystywane w projektowaniu optyki rentgenowskiej, opracowywaniu procedur kontroli materiałów i szkoleniach RT . Część 2: Tomografia komputerowa (CT) Część 3: Mikroradiografia i mikrotomografia komputerowa.
Źródło:
Badania Nieniszczące i Diagnostyka; 2016, 1-2; 37-43
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sześć rzeźb z serii górników manufaktury porcelany w Miśni ze zbiorów Muzeum Żup Krakowskich Wieliczka – historia i badania
Six sculptures of the miners – series made in the Meissen porcelain manufactory in the collection of the Cracow Saltworks Museum in Wieliczka – history and research
Autorzy:
Ochniak-Dudek, Klementyna
Lisińska-Kopacz, Anna
Wilkosz, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2054994.pdf
Data publikacji:
2021-10-10
Wydawca:
Muzeum Żup Krakowskich Wieliczka
Tematy:
porcelana
rzeźba górnika
Miśnia
J. J. Kaendler
1750 r.
XVIII w.
XIX w.
spektroskopia XRF
rentgenografia
fotografia analityczna
miner sculpture
Meissen
1750
18th century
19th century
X-ray fluorescence spectroscopy
X-ray radiography
analytical photography
porcelain
Opis:
Artykuł dotyczy zespołu sześciu porcelanowych figurek (wys. ok. 20 cm) z Miśni, od 2019 r. znajdujących się w zbiorach Muzeum Żup Krakowskich w Wieliczce. Rzeźby górników pochodzą ze znanej i cenionej serii, wymodelowanej przez Johanna Joachima Kaendlera i Petera Reinicke ok. połowy XVIII w. Opracowanie kompleksowo przedstawia historię i stan zachowania rzeźb. Pierwsza część artykułu – historyczno-artystyczna – stanowi szczegółowe studium opisujące wzory i historię obiektów na tle innych realizacji. Wnikliwie została udokumentowana kwerenda przeprowadzona przez Klementynę Ochniak-Dudek w zakresie literatury i istniejących kolekcji porcelany miśnieńskiej, a także dziejów manufaktury. Druga część artykułu prezentuje wyniki badań fizykochemicznych rzeźb, które dr Anna Klisińska-Kopacz i dr Tomasz Wilkosz wykonali w Laboratorium Analiz i Nieniszczących Badań Obiektów Zabytkowych Muzeum Narodowego w Krakowie. Wnioski autorów istotnie wzbogacają wiedzę o stanie zachowania i pozwalają rozstrzygnąć datowanie obiektów, jak również ostatecznie potwierdzają proweniencję czterech rzeźb z przedwojennej kolekcji Gustawa von Klemperera w Dreźnie. Ta część artykułu ma charakter pionierski na polskim gruncie, gdzie analityczne badania porcelany przeprowadzane są rzadko, a ich publikacje w zasadzie nie występują. Opracowanie muzealnych rzeźb o tematyce górniczej poszerza wiedzę z zakresu historii miśnieńskiej porcelany.
The article concerns a set of six porcelain figurines (approx. 20 cm high) from Meissen, since 2019 in the collection of the Cracow Saltworks Museum in Wieliczka. The sculptures presenting miners come from a well-known and respected series, modelled by Johann Joachim Kaendler and Peter Reinicke around the mid-18th century. The study comprehensively presents the history and condition of the sculptures. The first part of the article – a historical and artistic one – is a detailed study presenting the patterns and history of the exhibits compared to other implementations. The query carried out by Klementyna Ochniak-Dudek in the field of literature and existing collections of Meissen porcelain, as well as the history of the manufactory has been thoroughly documented. The second part of the article presents the results of physicochemical studies of sculptures that Anna Klisińska-Kopacz, PhD and Tomasz Wilkosz, PhD carried out at the Laboratory of Analysis and Nondestructive Investigation of Heritage Objects at the National Museum in Krakow. The authors’ conclusions significantly enrich the knowledge of the state of preservation, and allow for specification of the dating of objects, as well as finally confirm the provenance of four sculptures from the pre-war collection of Gustav Klemperer in Dresden. This part of the article is pioneering in Poland, where analytical porcelain research is rarely carried out and its publications are practically non-existent. The development of museum mining-related sculptures broadens the knowledge of the history of Meissen porcelain.
Źródło:
Studia i Materiały do Dziejów Żup Solnych w Polsce; 2021, XXXV, 1; 300-389
0137-530X
Pojawia się w:
Studia i Materiały do Dziejów Żup Solnych w Polsce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bezpośrednia radiografia cyfrowa
Digital direct radiography
Autorzy:
Jezierski, G.
Powiązania:
https://bibliotekanauki.pl/articles/214636.pdf
Data publikacji:
2017
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiografia cyfrowa
detektor typu płaski panel
amorficzny krzem (a-Si:H)
amorficzny selen
częstotliwość przestrzenna
funkcja przenoszenia modulacji (MTF)
kwantowa wydajność detekcji (DQE)
digital radiography
flat panel detector
amorphous silicon
amorphous selenium
spatial resolution
modulation
transfer function (MTF)
detective quantum efficiency (DQE)
Opis:
Dynamiczny rozwój radiografii cyfrowej (bazującej na elektronice) jaki obserwujemy w ostatnich latach skutkuje także zastosowaniem tej techniki do badań nieniszczących w przemyśle (NDT). Jednakże biorąc pod uwagę istotne różnice, przede wszystkim znacznie wyższe energie promieniowania rentgenowskiego stosowane do badania różnych obiektów przemysłowych (np. złącza spawane, odlewy, połączenia w elektronice), jak również konieczność dysponowania niekiedy lekkimi, przenośnymi detektorami powoduje, że nie da się bezpośrednio przenieść rozwiązań z medycyny do przemysłu. W niniejszej publikacji przedstawiono współczesne trendy oraz praktyczne rozwiązania detektorów cyfrowych do zastosowań w NDT.
Application of digital radiography (based on electronics) for imaging in medical practice has been recently dynamically developing, which results in implementation of this technique to industrial non-destructive testing (NDT). However, with respect to significant differences that include, first of all, much higher X-ray energies used for testing various object in industry (e.g. welds, castings, joints in electronic engineering) and often also necessity of using light, portable digital detectors, it is impossible to transfer solutions directly from medicine to industry. In this paper, modern trends and practical solutions of digital detectors designed for NDT are presented.
Źródło:
Postępy Techniki Jądrowej; 2017, 2; 37-44
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-44 z 44

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies