Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "radiation measurement" wg kryterium: Temat


Tytuł:
Radiation Shielding Properties of Some Composite Panel
Autorzy:
Al-Sarray, E.
Akkurt, İ.
Günoğlu, K.
Evcin, A.
Bezir, N.
Powiązania:
https://bibliotekanauki.pl/articles/1031289.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
radiation protection
composite material
radiation measurement
Opis:
With the discovering atomic nucleus, nuclear science started to be used in different fields and researcher focused on radiation protection as it is dangerous for human cell. Thus radiation physics and materials development becomes one of the important subject in science for this purposes. The developed material should be used for radiation shielding. In this work gamma ray shielding properties of some composite materials produced by polymer have been investigated.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 490-492
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on dose correction method of vehicle-borne environmental radiation measurement equipment
Autorzy:
Xu, Jie
Ren, Jizhou
Yang, Jianbo
Fan, Jiawen
Li, Rui
Li, Hui
Huang, Weiqi
Yuan, Biao
Powiązania:
https://bibliotekanauki.pl/articles/2055679.pdf
Data publikacji:
2021
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dose correction factor
reference radiation field
vehicle-borne environmental radiation measurement equipment
Opis:
This study establishes a near-ground reference radiation field based on typical radionuclides of the Fukushima accident in response to the need for vehicle-borne environmental radiation measurement equipment that can accurately evaluate the environmental dose of nuclear accidents. The Monte Carlo code FLUKA is used to study the environmental dose of such equipment in the early and mid-late reference radiation fields of nuclear accidents. Results of the air dose rate at 1 m above the ground were corrected to eliminate data difference between diverse measurement platforms. Simulation results show that t he dose correction factor (CF) fluctuates at approximately 0.8813 in the early reference radiation field and at approximately 0.6711 in the mid-late reference radiation field . This deviation of the dose CF in the early and mid-late reference radiation field s is within 2% and is not affected by the change in detector position. This research can be applied to obtain more accurate measurement of an ambient dose in the near-ground radiation field and support the vehicle-borne environmental radiation measurement technology.
Źródło:
Nukleonika; 2021, 66, 3; 103--110
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Głowica detekcyjna do pomiaru energii promieniowania optycznego na potrzeby mikroskopii
Detection head for measurements of radiation energy designed for microscopy
Autorzy:
Mikołajczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/208347.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
detekcja sygnałów optycznych
mikroskopia zakresu okna wodnego
wzmacniacz ładunkowy
promieniowanie optyczne
pomiar energii
pomiar promieniowania optycznego
detection of optical signals
water window microscopy
charge-sensitive preamp
optical radiation
energy measurement
optical radiation measurement
Opis:
W artykule przedstawiono projekt i wyniki badań parametrów dwuwidmowej głowicy detekcyjnej przeznaczonej do pomiaru energii promieniowania w zakresie długości fal od 2 nm do 4 nm. Ze względu na specyfikę tego promieniowania w głowicy zdecydowano się zastosować dwa tory pomiarowe wyposażone w różne filtry absorpcyjne. Dzięki odpowiedniemu doborowi charakterystyk transmisyjnych tych filtrów i ich skorelowaniu uzyskano możliwość pomiaru energii promieniowania w rozpatrywanym zakresie długości fal.
The paper presents a project and investigation results of a two-spectral detection head. The head provides measurement of radiation energy in the water window wavelength range. In the instrument, the two measurement channels with different absorption filters were applied. It was argued by absorption virtues of the spectrum. The selection and correlation of the filter transmissions makes it possible to correctly measure energy radiation in the "water widow" range.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 1; 339-349
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The process of aluminium moduls warming in the car industry
Autorzy:
Mlýnek, J.
Srb, R.
Powiązania:
https://bibliotekanauki.pl/articles/384339.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
intensity of heat radiation
experimental measurement of radiation intensity
interpolation in multidimensional space
software implementation
Opis:
This paper concerns the heating of aluminium moulds in the car industry. The moulds are intended for the production of artificial leathers. The mould is sprinkled with a special powder and is subsequently warmed by infra heaters located above the mould. It is necessary to ensure approximately the same heat intensity radiation on the surface mould, and in this way, the same material structure and colour of the artificial leather. The mould surface is described by its elementary surfaces. A producer uses moulds of different sizes and they are often very rugged. We must keep track of possible collisions of heater locations. We have used a genetic algorithm to optimize heater locations for a given mould. In this article, we will focus on the calculation procedure of thermal radiation intensity on the mould surface and on the determination of the average aberration of radiation intensity for particular heater locations, which is an important part of our genetic algorithm.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2012, 6, 2; 47-50
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nuklidy promieniotwórcze w wodach pitnych na Śląsku
Natural radioactivity in the drinking water in Upper Silesia region
Autorzy:
Chmielewska, I.
Chałupnik, S.
Mielnikow, A.
Hudzik, G.
Czapla, B.
Powiązania:
https://bibliotekanauki.pl/articles/340957.pdf
Data publikacji:
2011
Wydawca:
Główny Instytut Górnictwa
Tematy:
wody pitne
nuklidy promieniotwórcze
izotopy radu
drinking water
measurement of radiation
radium isotopes
Opis:
W kopalniach węgla Górnośląskiego Zagłębia Węglowego występują słone wody o podwyższonej promieniotwórczości naturalnej, związanej z występowaniem w nich izotopów radu. Wody te mogą powodować między innymi skażenie środowiska naturalnego, a efekty skażeń są od wielu lat przedmiotem badań i problem ten jest stosunkowo dobrze rozpoznany. Jednocześnie wody z płytko zalegających warstw wodonośnych są wodami o niskiej mineralizacji i niskich, a nawet bardzo niskich, stężeniach nuklidów promieniotwórczych. W niektórych przypadkach takie wody po uzdatnieniu są wykorzystywane jako wody pitne czy technologiczne w kopalniach. Wydawać by się mogło, że w tych przypadkach nie pojawią się żadne problemy związane z promieniotwórczością naturalną. Jednakże, długotrwała filtracja wód zawierających nawet bardzo niskie stężenia takich nuklidów promieniotwórczych, jak izotopy radu czy uranu, może prowadzić do ich adsorpcji w materiałach filtracyjnych stacji uzdatniania wód i powstawania substancji o podwyższonej promieniotwórczości naturalnej. Problemy takie stwierdzono już w kilku krajach europejskich (Finlandii, Szwecji czy Austrii), a wstępne wyniki badań filtrów piaskowych ze stacji uzdatniania wód w kopalniach GZW potwierdzają istnienie takiego zjawiska. Dodatkowo, wody podziemne mogą zawierać podwyższone stężenia radonu, który w procesach uzdatniania jest zazwyczaj uwalniany do powietrza w stacji uzdatniania, co może powodować znaczący wzrost narażenia radiacyjnego pracujących tam ludzi. Takie procesy są długotrwałe i dlatego jest wskazane prowadzenie badań przez okres kilku lat, przede wszystkim w stacjach uzdatniania wód przy kopalniach węgla.
Drinking Water Directive of European Union requires a monitoring of the quality of drinking waters in Member States, also measurements of natural radioactivity. Although only for H-3 the permissible level has been established directly (100 Bq/l), for other radionuclides the Total Indicative Dose (TID) due to its intake is 0.1 mSv/year. For the monitoring of the drinking water quality a complex of methods for chemical preparation and measurements have been developed and implemented. It consists of following steps – at first, tritium analysis is done as well as gross alpha and gross beta activity is measured for each sample. For both of latter measurements liquid scintillation spectrometry with use of low level LS spectrometer Quantulus is applied. Afterwards, radium analysis is made, measurements are done for Ra-226 and Ra-228 simultaneously in LS spectrometer, preceded by chemical separation of radium from water sample with barium carrier. Simultanously to radium measurement, Pb-210 analysis is done in all samples, after coprecipitation with stable lead carrier the resulting precipitate is mixed with gelling scintillator and measurement is performed with use of Quantulus. Also uranium determination is done, at first uranium is retained at anionic ion exchange resin, than purified by means of UTEVA resin (Triskem). Finally the electrodeposition of uranium is performed and resulting sample is measured by alpha spectrometry.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2011, 2; 29-38
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological requirements for measurements of circadian radiation
Autorzy:
Jakubowski, P.
Fryc, I.
Powiązania:
https://bibliotekanauki.pl/articles/174805.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
circadian radiation
optical measurement
LED lighting
Opis:
The article presents a definition of circadian radiation and its influence on human beings. Typical sources of this radiation have been discussed and compared. As the availability of devices designed for circadian radiation measurement is very limited, and their quality is rather poor, there is a need for the development of a new meter which would deliver precise data. The paper presents available methods of optical radiation measurement which can be used in a circadian radiation assessment. Advantages and disadvantages of presented methods have been discussed. A light path in typical measurement instruments has been analyzed, as well as the impact of each component on the final result (i.e. the influence of spatial correction, optical filters and detectors). Original results of authors’ research have been presented and the concept for decreasing the measurement error has been proposed.
Źródło:
Optica Applicata; 2018, 48, 4; 697-704
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiation monitoring network in Poland
Autorzy:
Grabowski, D.
Kurowski, W.
Muszynski, W.
Rubel, B.
Smagala, G.
Swietochowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/148070.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
measurement stations
radiation monitoring
warning network
Opis:
In Poland the radioactive contamination of the environment and food has been controlled since the early sixties by the Service for Measurements of Radioactive Contamination (SPSP). The Service comprises a network of measuring stations and the Centre of Radioactive Contamination Measurements (COPSP). Actually, there are 100 measurement stations. The main task of such station is systematic measurement of radioactivity level in samples of environment components and food. Nine stations of SPSP acting within meteorological stations, ten stations of low level air radioactivity measurements (Aerosols Sampling Stations ASS-500) and eleven permanent monitoring stations (PMS) form the radiation monitoring warning system in Poland.
Źródło:
Nukleonika; 2001, 46, 4; 147-149
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiplatform dedicated control - measurement systems
Autorzy:
Szulim, R.
Szperkowska, M.
Sieluk, W.
Powiązania:
https://bibliotekanauki.pl/articles/114446.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
multiplatform systems
control – measurement systems
radiation monitoring systems
Opis:
The paper presents some issues with developing dedicated software solutions for control – measurement systems equipped with Graphical User Interface (GUI) and touchscreen dedicated to work under different operating systems like MS Windows and Linux. Some important issues of preparing the system to work under different operating system environment using common software code are described. As an example of a practical solution, the control system of the radiation monitor produced by Relpol S.A. built using the QT multi-platform development environment is presented.
Źródło:
Measurement Automation Monitoring; 2016, 62, 7; 241-244
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Buildup Factor in Gamma-Ray Measurement
Autorzy:
Akyildirim, H.
Waheed, F.
Günoğlu, K.
Akkurt, İ.
Powiązania:
https://bibliotekanauki.pl/articles/1031578.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Gamma-rays measurement
Radiation protection
Buildup factor
Gamma Spectrometer
Geometry
Opis:
Gamma ray measurement is an important issue in nuclear technology, since it is widely used in industry, medicine, agriculture, education research, and some military applications. Gamma ray is also needed to build radiation protection, which is very useful for human health. When gamma radiation penetrates through shielding material, it generates two radiation components within or beyond the shield, namely: the uncollided and the collided photons. Therefore, the buildup factor is an important parameter for gamma ray measurement. Buildup factor is defined as the ratio of the total number of particles at a given point to the number of uncollided particles, at that same point. In this work, we evaluate the gamma-ray buildup factors for copper (Cu-29), as a function of energy, for 0.511, 0.662, 1.275 MeV, by using cesium and sodium radioactive sources. The results show that the value of energy buildup factor decreases with increasing gamma energy, and increases with increasing thickness. Moreover, it was found that at high energies (1.275 MeV), the absorption buildup factor is at minimum when the energy is at high level. The results also reveal that there is no contribution from the scattering photons to the value of buildup factor, in general, at low intensity levels, when the geometry structure is built well. While for bad geometry, the detector measures intensity, which is greater than that described by the main linear attenuation coefficient, because the scattered photons will be detected as well. All in all, in order to get rational results, a well geometry should be used for the future applications.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 1203-1206
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Czynniki wpływające na pomiar pirometrów radiacyjnych
Factors influencing on the radiation pyrometers measurement
Autorzy:
Obiegło, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/952620.pdf
Data publikacji:
2018
Wydawca:
Główny Urząd Miar
Tematy:
pirometr radiacyjny
pomiar temperatury
wzorcowanie
radiation pyrometer
temperature measurement
calibration
Opis:
Wydział Metrologii Elektrycznej, Fizykochemii, Akustyki, Drgań i Promieniowania Optycznego Okręgowego Urzędu Miar w Gdańsku posiada stanowisko do wzorcowania pirometrów radiacyjnych wyposażone w kalibratory typu 4180 i 4181 produkcji Fluke. Laboratorium OUM wykonuje wzorcowania tych przyrządów i przygotowuje się do akredytacji w PCA w zakresie pomiarowym od -15 °C do 500 °C. W artykule przedstawiono spostrzeżenia dotyczące czynników najbardziej wpływających na pomiar.
Regional Office of Measures in Gdańsk Electric Metrology Physics-Chemistry, Acoustics, Vibration and Optical Radiation Division has a calibration stationwith calibrators type 4180 and 4181 manufactured by Fluke. The Laboratory is already performing calibrations and measurements of devices and also the laboratory is preparing for PCA accreditation in range from -15 °C to 500 °C. In the article, the remarks on the factors that most affect the radiation pyrometers measurement are presented.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2018, 2 (21); 31-35
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of the pre-irradiation storage procedure on the dose response of a Fricke xylenol orange gel dosimeter
Autorzy:
Liosi, G. M.
Giacobbo, F.
Pignoli, E.
Carrara, M.
Gambarini, G.
Mariani, M.
Powiązania:
https://bibliotekanauki.pl/articles/147138.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radiation dosimetry
Fricke-gelatin-xylenol orange dosimeter
optical absorbance measurement
Opis:
The Fricke xylenol orange (FX) gel system is a chemical dosimeter characterized by good sensitivity, linear dose response, tissue equivalence, no toxicity, easy preparation, reproducibility and low cost. Thanks to the presence of the gelatinous matrix, the system is particularly suitable to perform reliable 3D mapping of the absorbed dose spatial distribution via magnetic resonance imaging (MRI) or optical techniques. The aim of this work is to study in a systematic way the influence of the pre-irradiation storage procedure upon sensitivity, dose response stability and lifetime of use of a FX gel system made with gelatin from porcine skin subjected to homogeneous irradiation. For this purpose, different pre-irradiation storage procedures, in terms of temperature and duration of each storage step, were investigated. In order to evaluate the dose response stability, the optical analyses of the samples were performed up to 6 hours after irradiation. Moreover, the samples were irradiated at time intervals of 24 hours for up to 7 days after preparation in order to evaluate the system lifetime of use. Regardless of their thermal and temporal life, the samples show linear dose responses in the investigated dose range (3–24 Gy) and an increase of sensitivity with the time elapsed between preparation and irradiation. Among the three pre-irradiation storage procedures considered here, a procedure that provides the best dose response stability and lifetime of use was identifi ed and recommended for further use. The analyzed dosimetric system possesses good properties that make it promising for medical application, particularly concerning the evaluation of pre-treatment plan quality assurance within the conformational external beam radiotherapy.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 603-607
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instalacje słoneczne w ośrodku szkoleniowo-badawczym w zakresie energii odnawialnej w Ostoi
Solar systems at Training and Research Centre for Renewable Energy in Ostoja
Autorzy:
Zapałowicz, Z.
Batko, B.
Dawidowski, J. B.
Rogalska, P.
Powiązania:
https://bibliotekanauki.pl/articles/288548.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
kolektor słoneczny
fotowoltaika
pomiar
promieniowanie słoneczne
solar collector
photovoltaics
solar radiation
measurement
Opis:
W komunikacie zamieszczono opis zainstalowanych w Ośrodku Szkoleniowo-Badawczym w Zakresie Energii Odnawialnej w Ostoi urządzeń wykorzystujących promieniowanie słoneczne oraz stacji pomiaru promieniowania słonecznego. Przedstawiono też możliwości prowadzenia badań wykorzystania energii słonecznej do wytwarzania ciepła i energii elektrycznej.
The announcement contains description of equipment installed at Training and Research Centre for Renewable Energy in Ostoja to utilise solar radiation, and solar radiation measuring station. Moreover, the work presents possibilities as regards carrying out the research on using solar energy to generate heat and electric energy.
Źródło:
Inżynieria Rolnicza; 2009, R. 13, nr 1, 1; 361-367
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement system for IR absorption
Układ pomiaru tłumienia promieniowania podczerwonego
Autorzy:
Neska, M.
Powiązania:
https://bibliotekanauki.pl/articles/256772.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
infrared radiation
infrared detector
measurement uncertainty
promieniowanie podczerwone
detektor podczerwieni
niepewność pomiaru
Opis:
Radiation absorption measurement systems are widely used in the evaluation of different types of materials. They require a stable transceiver radiation measuring circuit. The article presents a transceiver infrared radiation system developed by the author, in which, apart from a stabilized power supply of transmitting and receiving subsystems, the dedicated software for temperature correction of output signals was also used. The system has two measuring circuits at wavelengths of 860 nm and 950 nm. The paper presents characteristics and measurement uncertainties of the system, determined by means of the reference material. This type of a system can be used in systems for IR transmission or reflection tests, and it can be of help in radiation absorbance studies.
Układy pomiaru tłumienia promieniowania znajdują szerokie zastosowanie w ocenie różnych typów materiałów. Wymagają one stabilnego toru nadawczo-odbiorczego promieniowania. W artykule przedstawiono opracowany układ nadawczo-odbiorczy promieniowania podczerwonego, w którym obok stabilizowanych źródeł zasilania podukładów, nadawczego i odbiorczego, zastosowano programową korekcję temperaturową sygnałów wyjściowych. Układ posiada dwa tory pomiarowe o długościach fal 860 i 950 nm. W artykule zaprezentowano charakterystyki i niepewności pomiarowe układu wyznaczone przy wykorzystaniu referencyjnego materiału. Układ tego typu może być zastosowany w systemach badania przepuszczalności lub odbicia światła podczerwonego, czy badaniach absorbancji promieniowania.
Źródło:
Problemy Eksploatacji; 2015, 1; 91-100
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Examination of spectral distribution of radiation emitted by halogen and xenon lamps
Autorzy:
Ratajczak, J.
Wiczyński, G.
Domke, K.
Powiązania:
https://bibliotekanauki.pl/articles/97417.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
spectral distributions of xenon and halogen lamp
spectrometer measurement
combined radiation
Opis:
Most often, solar radiation simulators are built with a certain lamp type - halogen, xenon, metal halogen or, less frequently, sulphur lamps. The knowledge of radiation spectra of these lamps is a prerequisite to correctly design a solar radiation simulator. On many occasions, two lamps used simultaneously provide better adjustment of the simulator's radiation to solar radiation. This is especially beneficial in case of simulators dedicated to selected solar radiation receivers with specific sensitivity range, e.g. photovoltaic panels or solar collectors. The article presents the test bed and results of examination of summary spectral distributions of xenon and halogen lamp. Proper mixing of radiation of these lamps allows better adjustment of the simulator's radiation to the needs of a specific receiver of real solar radiation.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 363-369
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies