Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pulsed" wg kryterium: Temat


Tytuł:
Static characteristics of pulsed actuator with plunger consisting of carbon steel and permanent magnet
Autorzy:
Doležel, I.
Pánek, D.
Ulrych, B.
Powiązania:
https://bibliotekanauki.pl/articles/376540.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
pulsed actuator
electromagnetic actuator
Opis:
A novel type of pulsed electromagnetic actuator is presented and modeled. Its plunger consists of two separate (but mutually connected) cylindrical parts made of classical magnetic material and permanent magnet, respectively, and its motion is controlled by short current pulses of the defined amplitude. The paper starts with the definition of the technical problem and formulation of its mathematical model. This model is then solved numerically and the whole methodology is illustrated by a typical example. It is shown that unlike the classical devices the above actuator exhibits high holding force and low consumption of energy.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 72; 65-74
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Static characteristics of pulsed actuator with combined plunger
Autorzy:
Doležel, I.
Pánek, D.
Ulrych, B.
Powiązania:
https://bibliotekanauki.pl/articles/97389.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electromagnetic actuator
plunger
pulsed actuator
Opis:
A novel type of pulsed electromagnetic actuator is presented and modelled. Its plunger consists of two cylindrical parts made of classical magnetic material and permanent magnet, respectively. Its motion is controlled by short current pulses of the prescribed amplitude. The paper starts with the definition of the technical problem and formulation of its mathematical model. This model is then solved numerically and the whole methodology is illustrated by a typical example, whose results are discussed.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 127-136
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Compensated ionization chamber for (n,α) reaction measurements at a spallation neutron source
Autorzy:
Andrzejewski, J.
Yu, M.
Gledenov, M.
Korejwo, A.
Sobczak, K.
Szałański, P.
Powiązania:
https://bibliotekanauki.pl/articles/146570.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ionization chamber
pulsed neutron source
Opis:
The new spallation neutron facility n_TOF (neutron time-of-flight) at CERN opens wide possibilities in measurements of neutron induced reaction cross sections. The facility with its excellent energy resolution of neutrons, low repetition rate and most important – with a very high instantaneous luminosity, makes up an extra challenge for experimenters faced by doing measurements at a high peak intensity spallation source. Our proposition is directed to the use of a compensated ionization chamber for the (n, alpha) reaction cross section measurements we plan to carry out in a wide range of neutron energy. First experience gained with using such a kind of detector at ORELA (the Oak Ridge Electron Linear Accelerator) neutron source (ORNL) was very optimistic.
Źródło:
Nukleonika; 2007, 52, 2; 51-57
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GaAs/AlGaAs (~9.4 žm) quantum cascade lasers operating at 260 K
Autorzy:
Bugajski, M.
Kosiel, K.
Szerling, A.
Kubacka-Traczyk, J.
Sankowska, I.
Karbownik, P.
Trajnerowicz, A.
Pruszy, E.
Pierciński, K.
Pierścińska, D.
Powiązania:
https://bibliotekanauki.pl/articles/200656.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quantum cascade lasers
pulsed mode
Opis:
The fabrication of Quantum Cascade Lasers (QCLs) emitting at 9.4 um is reported. The devices operated in pulsed mode at up to 260 K. The peak powers recorded in 77 K were over 1 W, and the slope efficiency 0.5–0.6 W/A per uncoated facet. This has been achieved by the use of GaAs/Al0.45Ga0.55As heterostructure, with 3QW anticrossed-diagonal design originally proposed by Page et al. [1]. Double plasmon planar confinement with Al-free waveguide has been used to minimize absorption losses. The double trench lasers were fabricated using standard processing technology, i.e., wet etching and Si3N4 for electrical insulation. The QCL structures have been grown by Molecular Beam Epitaxy (MBE), with Riber Compact 21T reactor. The stringent requirements – placed particularly on the epitaxial technology – and the influence of technological conditions on the device structure properties are presented and discussed in depth.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2010, 58, 4; 471-476
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Propagation of pulsed sound signals on a shelf of free tidal sea: effects from coastal eddies and internal waves
Autorzy:
Mikryukov, A.
Popov, O.
Serebryany, A.
Powiązania:
https://bibliotekanauki.pl/articles/331674.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
pulsed sound signal
Black Sea
hydroacoustic
Opis:
A long term experiment on studying fluctuations of the parameters of pulsed sound signals in a shallow sea was carried out in the region of the northeastern coast of the Black sea in autumn, 2004. the data were collected on a 1.2-km fixed propagation pathat a 2-km distance from the coastline. During the entire experimentation, observations of temperature fluctuations near the receiving point were performed by the using the line temperature sensor. Fluctuations of the shape, energy and propagation time of the pulsed signals were studied. an attempt of their relation to the hydrodynamic processes on the shelf was taken. The change in the shape and the energy levelof the signal was analyzed for the moment of passing the anticyclonic topographic eddy over the coastal zone. It was shown that the fluctuations of the propagation time were sometimes as high as 17.6 ms. An enhanceof the short-period acoustic fluctuations accompanying the internsification of the internal waves was observed.
Źródło:
Hydroacoustics; 2008, 11; 279-288
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polish Artificial Heart - new coatings, technology, diagnostics
Autorzy:
Sarna, J.
Kustosz, R.
Major, R.
Lackner, J.
Major, B.
Powiązania:
https://bibliotekanauki.pl/articles/200025.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pulsed laser deposition
microstructure
cell adhesion
Opis:
Since 1991, the Foundation for Cardiac Surgery Development in Zabrze has been implementing research on the artificial heart. In 1995, an artificial ventricle, POLVAD, was implanted to a patient, and in 1998, the prototype of a clinical controller, POLPDU-401, was created. A further development of the studies on an implantable artificial heart requires an integrated approach and an application of advanced methods of materials sciences in order to develop new materials suitable for the contact with blood, as well as to apply a multilateral biomedical diagnostics in hydrodynamic conditions. The estimation of the cell–material interaction plays an important role in the biomaterial design. An analysis of the influence of the carbon content in titanium nitride on the biological and biophysical properties of biomaterial coatings was studied. The cell-material reactions were considered in dynamic and static conditions. Three groups of materials were under examinations – titanium nitride (TiN), as well as titanium carbonitride with a low and high carbon content – of which the best properties were observed for TiN. We found a strong influence of the stoichiometry of TiN (atomic ratio of Ti/N) on the biocompatibility. A non-stoichiometric TiN could have a negative influence on the surrounding tissue.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2010, 58, 2; 329-335
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative efficacy of kneading massage and pulsed mode ultrasound in the management of chronic knee osteoarthritis
Autorzy:
O. Ojoawo, Adesola
Abiodun Fatai, Wasiu
Powiązania:
https://bibliotekanauki.pl/articles/2040133.pdf
Data publikacji:
2020-12-30
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
kneading massage
knee osteoarthritis
pulsed ultrasounds
Opis:
Introduction. Osteoarthritis of the knee is the most common presentation of osteoarthritis with prevalence between 12% and 35% of general population and is considered the leading cause of musculoskeletal disability in the elderly population worldwide. Aim. The study compared efficacy of kneading massage and pulsed ultrasound on pain, joint stiffness and difficulty in knee osteoarthritis (KOA). Material and methods. Fifty subjects with radiological evidence of KOA participated in the study. They were randomly allocated into kneading massage group (KMG) (25) and Ultrasound group (USG) (25). KMG received kneading massage for 7 minutes while USG received pulsed mode ultrasound for 15 minutes. Treatment was twice in a week for six weeks. Pain intensity (PI), joint stiffness and difficulty were assessed pre, 3rd and 6th weeks of treatment session with semantic differential scale and WOMAC. The data were analyzed using descriptive and inferential statistics, alpha level was set at 0.05 Results. There was a significant difference in present PI (F=11.45,P=0.001) and stiffness (F= 11.32, P=0.003) in USG. There was a significant reduction in PI (F=7.95, P=0.001) and joint stiffness (F=8.86, P=0.003) in KMG. At the 6th week, there was a significant differences in PI (t=12.23,P=0.000) and stiffness (t=8.08, P=0.000) when USG (3.00+0.4, vs 7.14+ 1.49) was compared with KMG (3.16+0.5 vs 7.50+1.5). Conclusion. Ultrasound (US) and kneading massage (KM) reduced PI and joint stiffness of KOA effectively; however US reduced PI than KM while KM reduces joint stiffness than US.
Źródło:
European Journal of Clinical and Experimental Medicine; 2020, 4; 275-280
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Liquid micro pulsed plasma thruster
Autorzy:
Szelecka, A.
Kurzyna, J.
Daniłko, D.
Barral, S.
Powiązania:
https://bibliotekanauki.pl/articles/146591.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
electric propulsion
pulsed plasma thruster
liquid propellant
Opis:
A new type of pulsed plasma thruster (PPT) for small satellite propulsion is investigated, of which the most innovative aspect is the use of a non-volatile liquid propellant. The thruster is based on an open capillary design. The thruster achieved a thrust-to-power ratio above 45 μN/W, which constitutes a 5-fold improvement over the water-propelled pulsed plasma thruster, and which is also slightly above the performance of a similarly sized PPT with a solid propellant.
Źródło:
Nukleonika; 2015, 60, 2; 257-261
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ion implantation followed by laser/pulsed plasma/ion beam annealing : a new approach to fabrication of superconducting MgB2 thin films
Autorzy:
Piekoszewski, J.
Werner, Z.
Barlak, M.
Kolitsch, A.
Szymczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/146817.pdf
Data publikacji:
2008
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
MgB2
superconducting films
pulsed plasma annealing
Opis:
The paper presents a new approach to formation of superconducting MgB2 thin films: ion implantation followed by annealing in an unconventional second step treatment using pulsed laser, plasma, or ion beams. Merits and drawbacks of individual approaches are discussed.
Źródło:
Nukleonika; 2008, 53, 1; 7-10
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Present status and prospects of research in SINS on the modification of surface properties by pulsed plasma streams
Autorzy:
Langner, J.
Piekoszewski, J.
Stanisławski, J.
Werner, Z.
Powiązania:
https://bibliotekanauki.pl/articles/146758.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
IONOTRON plasma injector
pulsed plasma processing
surface modification
Opis:
The paper presents examples of the most important results obtained in SINS during the last decade, interesting from the point of view of industrial applications. It also indicates some of the most prospective directions in research on modification of the surface properties of materials by means of pulsed plasma streams.
Źródło:
Nukleonika; 2000, 45, 3; 193-197
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of the Pulsed High Magnetic Field on Fusarium culmorum (W.G. Smith) Sacc
Wpływ impulsowego, wysokiego pola magnetycznego na Fusarium culmorum (W.G. Smith) Sacc
Autorzy:
Gorczyca, A.
Janas, P.
Kasprowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/388653.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
impulsowe pole magnetyczne
F. culmorum
pulsed magnetic field
Opis:
The aim of the investigations was an assessment of the impact of the pulsed high magnetic field on a concentrated spore suspension of F. culmorum fungus, which is a dangerous pathogen of many crops. 5, 10, 15 and 20 pulses of 9 Tesla induction were applied. The pulsed magnetic field limited germination of the tested strain. A significant difference was found for 15 and 20 pulses. Mycelial linear growth was also reduced, as was found both for the inoculation and logarithmic phase of growth in Petri dish culturing, however, no limited mycelium sporulation was observed. There is a potential for the application of the tested physical method – the pulsed high magnetic field to limit the development and harmfulness of F. culmorum.
Celem przeprowadzonych badań była ocena wpływ impulsowego, wysokiego pola magnetycznego na skoncentrowaną zawiesinę zarodników grzyba F. culmorum, groźnego patogena wielu roślin uprawnych. Zastosowano 5, 10, 15 i 20 impulsów pola magnetycznego o indukcji 9 Tesli. Impulsowe pole magnetyczne ograniczyło kiełkowanie badanego szczepu. Istotną różnicę stwierdzono dla 15 i 20 impulsów. Wzrost liniowy grzybni również ulegał ograniczeniu, co stwierdzono zarówno dla inokulacji, jak i fazy logarytmicznej wzrostu w hodowli szalkowej. Nie zaobserwowano jedynie ograniczenia sporulacji grzybni. Istnieje możliwość wykorzystania testowanej metody fizycznej - impulsowego wysokiego pola magnetycznego - do ograniczania rozwoju i szkodliwości F. culmorum.
Źródło:
Ecological Chemistry and Engineering. A; 2011, 18, 11; 1477-1484
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Green Approach to Intensify the Extraction Processes of Substances from Plant Materials
Autorzy:
Malyushevskaya, Antonina
Koszelnik, Piotr
Yushchishina, Anna
Mitryasova, Olena
Gruca-Rokosz, Renata
Powiązania:
https://bibliotekanauki.pl/articles/2173315.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
green approach
plant material
extraction
polysaccharides
pulsed electric field
Opis:
The principles of sustainable development and green chemistry are priorities in the development of new technologies for the extraction of useful biologically active substances, for example, in the manufacture of medicines. The processes of extracting substances from plant raw materials have many applications. Intensification of such processes, reducing their duration, energy consumption and consumption of the extractant is urgent. The object of the reseach is the green approach to intensify the extraction processes of polysaccharide substances from plant materials. The research methodology was experimental with statistical data processing. In the field of experimental research was the process of the influence of pulsed, alternating and direct current on the intensity of aqueous extraction of polysaccharides from plant materials. The high efficiency of intensification of extraction by a pulsed electric field was studied. The process can reduce the time for obtaining water-soluble polysaccharides by 3 times in comparison with traditional pharmacopoeial convection methods and reduce energy consumption by 20 times. The significance of the pulse current parameters for effective extraction was determined: the referred pulse shape, the frequency of the pulse current for extracting the maximum amount of water-soluble polysaccharides, the pulse duration, and the optimal processing time. The green approach to the use of a moderate electric field of pulsed current to accelerate the extraction of biologically active substances is the basis of the method of intensification of other traditional mass transfer processes for the sustainable development of technology.
Źródło:
Journal of Ecological Engineering; 2022, 23, 7; 197--204
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Pulse Thermography (PT) and Step Heating (SH) Thermography in Non-Destructive Testing of Unidirectional GFRP Composites
Autorzy:
Kamińska, Paulina
Ziemkiewicz, Jarosław
Synaszko, Piotr
Dragan, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/97879.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
pulsed thermography
step-heating thermography
composites
NDT
NDE
GFRP
Opis:
This paper presents two techniques of active thermography i.e. the pulsed thermography technique and the step heating technique. The aim of this article is to compare these two techniques and present the possibilities, advantages and limitations of their use in the context of non-destructive testing of composite materials. The experimental section presents the results of tests carried out on samples of the polymer composites reinforced with glass fiber.
Źródło:
Fatigue of Aircraft Structures; 2019, 11; 87-102
2081-7738
2300-7591
Pojawia się w:
Fatigue of Aircraft Structures
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanisms for self-assembling topography formation in low-temperature vacuum deposition of inorganic coatings on polymer surfaces
Autorzy:
Lackner, J.
Waldhauser, W.
Alamanou, A.
Teichert, C.
Schmied, F.
Major, L.
Major, B.
Powiązania:
https://bibliotekanauki.pl/articles/200047.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
topography
roughness
coatings
pulsed laser deposition
magnetron sputtering
polymers
Opis:
Functionalization of surfaces is an important task for nanotechnology to add specially designed physico-chemical properties to materials. Besides chemical modification of surfaces, physical adaptations gain increasing interest. Thus, understanding the influences of film deposition on surface topography formation is the basis for future developments. For physical or chemical vapour deposited (PVD, CVD) films, structure zone models were developed, clearly showing the influences of temperature and vapour energy and, thus, surface and bulk diffusion on film structures based on four different structure zones. Generally, similar zones are also found in PVD coatings on polymeric substrates; However, due to restrictions in coating temperatures due to the thermal resistance of most polymers, the coating temperature is restricted to mostly 50°C, excluding thermal activation of at least surface diffusion of inorganic materials (metals and their nitrides, oxides, carbides, etc.) and resulting in columnar growth with dome-shaped column tops. Additionally, the high difference in mechanical properties between “stiff” inorganic coatings and “flexible” polymers implicates stress-induced growth phenomena, resulting in wrinkling, cracking and finally the formation of a superseding structure, depending on substrate and film materials and the vapour energy of the deposition method.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2010, 58, 2; 281-294
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the approach to the analysis of the growth of epitaxial layers by pulsed laser deposition
Autorzy:
Pankratov, Evgeny L.
Powiązania:
https://bibliotekanauki.pl/articles/29520091.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
pulsed laser deposition
mass transport
heat transport
analytical modelling
Opis:
This paper considers an analytical approach for the prognosis of mass and heat transport during the growth of epitaxial layers by means of pulsed laser deposition. The approach provides the opportunity to make a prognosis which takes into account the spatial and temporal variations of their parameters and, at the same time, the nonlinearity of these processes. Based on this approach, the influence of the variation of several parameters on the growth process is investigated.
Źródło:
Computer Methods in Materials Science; 2021, 21, 4; 203-208
2720-4081
2720-3948
Pojawia się w:
Computer Methods in Materials Science
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies