Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pulse transformer" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Optimization of the pulse transformer using circuit-field model
Autorzy:
Łyskawiński, W.
Knypiński, Ł.
Nowak, L.
Jędryczka, C.
Powiązania:
https://bibliotekanauki.pl/articles/1395761.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
pulse transformer
optimization
genetic algorithm
Opis:
The paper presents the new strategy of the optimization of pulse transformer (PT). In order to reduce calculation time the optimization problem has been decomposed into two stages. In the first stage, to determine functional parameters of PT the circuit model is used. The goal of circuit calculations is to limit the space of design variables that meets formulated requirements. The genetic algorithm has been applied for this task. In order to include constraints, the penalty function has been engaged. The transformer dimensions obtained in the first stage of calculations are used as initial values in the second stage of design process. In the second stage the field model of PT is employed. Obtained results prove that presented approach allows for fast optimization of the PT design.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 159-167
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite element analysis of eddy current losses in pulse transformer
Analiza strat wiroprądowych w transformatorze impulsowym metodą elementów skończonych
Autorzy:
Łyskawiński, W.
Powiązania:
https://bibliotekanauki.pl/articles/159946.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
transformator impulsowy
straty wiroprądowe mocy
metoda elementów skończonych
pulse transformer
eddy current losses
FEM analysis
Opis:
In the paper an algorithm for power loss determination in pulse transformers using a field-circuit model is described. The software based on the algorithm is used to calculate eddy current losses and determine efficiency of a pulse transformer. Eddy current power losses and efficiency of a pulse transformer for different load resistances, input signal shapes and lengths of the central leg of the core are analysed. Selected results of simulations are shown.
Wiroprądowe straty mocy ΔP w transformatorze impulsowym można wyznaczyć na podstawie czasowego przebiegu oraz przestrzennego rozkładu wektora gęstości prądu z zależności (1). Obliczanie tych strat jest jednak zagadnieniem trudnym, ponieważ w ogólnym przypadku przy wymuszeniu napięciowym w układach zawierających elementy nieliniowe nie jest znany a priori przebieg i rozkład gęstość prądu w uzwojeniach i prądów wirowych w rdzeniu. W celu wyznaczenia tych prądów posłużono się modelem polowo-obwodowym transformatora impulsowego. Model ten obejmuje równania pola elektromagnetycznego (3) i równania opisujące rozpływ prądów w obwodach elektrycznych (2). Ze względu na nieliniowość, szybką zmienność pola w czasie oraz złożoną strukturę równań tych nie można rozwiązać analitycznie. W tym celu wykorzystuje metodę elementów skończonych, polegającą na dyskretyzacji przestrzeni i czasu. W wyniku uzyskuje się układ nieliniowych równań algebraicznych (4). Do rozwiązania tego układu równań wykorzystuje się iteracyjną metodę Newtona-Raphsona. Na podstawie obliczonych rozkładów gęstości prądów z zależności (1) wyznacza się wiroprądowe straty mocy w rdzeniu i straty mocy w uzwojeniach. Na podstawie przedstawionego algorytmu opracowano program do wyznaczania wiroprądowych strat mocy i sprawności w transformatorze impulsowym. Rozpatrzono transformator o mocy 240 W z rdzeniem ETD 44 wykonanym z ferrytu N 67 o strukturze przedstawionej na rys. 1. W rozważaniach uwzględniono nieliniowe właściwości materiałów magnetycznych oraz prądy wirowe indukujące się w rdzeniu i uzwojeniach. Transformator obciążono rezystancją Ro. Dla Ro = Rn uzyskano znamionowy prąd obciążenia. Ze względu na szeroki zakres zmian względnej rezystancji obciążenia r = Ro/Rn na zamieszczonych w artykule wykresach posłużono się skalą logarytmiczną. Badano wpływ zmian względnej rezystancji obciążenia r i kształtu sygnału zasilającego na względne straty mocy w uzwojeniach pu = ΔPu /ΔPun (rys. 2) i w rdzeniu pr = ΔPr /ΔPrn (rys. 3) oraz sprawność η transformatora (rys. 6). Przy obliczaniu sprawności uwzględniono straty histerezowe wyznaczone w sposób przybliżony na podstawie danych katalogowych. Sprawność tą porównano w pewnym zakresie obciążeń ze sprawności transformatora pracującego w zasilaczu impulsowym (rys. 4). Opracowane oprogramowanie umożliwia analizę wiroprądowych strat mocy w uzwojeniach i rdzeniu transformatorów impulsowych. Zatem może być przydatne w projektowaniu i optymalizacji rozpatrywanych transformatorów.
Źródło:
Prace Instytutu Elektrotechniki; 2006, 229; 75-85
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of a High-voltage Switching Power Supply Parameters
Autorzy:
Martemianov, Boris
Ryzhkov, Alexander
Vdovin, Grigoriy
Powiązania:
https://bibliotekanauki.pl/articles/2055213.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high voltage
low power
power supply
microchannel plate
MCP
MCP detector
low signal
Cockcroft-Walton
voltage multiplier
pulse generator
pulse transformer
voltage stabilizer
Opis:
A principle diagram of a high-voltage low-power power supply for devices comprising a microchannel plate (MCP) has been developed. A mathematical model was built according to the developed scheme for a detailed study of the operation of the power supply and the selection of the optimal parameters of its components and obtaining the best output voltages. The power supply circuit comprises a control circuit, a pulse transformer, a voltage multiplier circuit, a feedback circuit, and an input stabilizer. The input stabilizer provides the maintenance of the voltage switched in the primary winding of the transformer at a given level regardless of the voltage drop of the power supply primary source. Moreover the stabilizer provides constant voltage maintenance when the load resistance changes. (with Rload changing from 100 to 200 MΩ, Uout did not exceed 3 V).
Źródło:
International Journal of Electronics and Telecommunications; 2021, 67, 4; 711--716
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of hysteresis loss in pulse transformer
Autorzy:
Łyskawiński, W.
Sujka, P.
Szeląg, W.
Barański, M.
Powiązania:
https://bibliotekanauki.pl/articles/140918.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
straty histerezowe
transformator impulsowy
zjawiska sprzężone
model Jilesa-Athertona
hysteresis loss
pulse transformer
coupled electromagnetic-thermal phenomena
Jiles-Atherton model
Opis:
In the paper, the mathematical model of coupled electromagnetic and thermal phenomena in the pulse transformer taking into account the magnetic hysteresis is presented. For the mapping of magnetic hysteresis, Jiles-Atherton model is applied. In order to solve field equations, the finite element method (FEM), "step-by-step" procedure and Newton-Raphson algorithm are used. Software elaborated on this basis is used for analysis of hysteresis loss in the core. Selected results of investigations are shown.
Źródło:
Archives of Electrical Engineering; 2011, 60, 2; 187-195
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The DC-side active filter with dual-buck full-bridge inverter for wind generators
Autorzy:
Chen, X-Q.
Zhao, S-W.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/141358.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
multi-pulse ac-dc converter
auto-transformer
harmonic suppression
DC-side active filter
dual-buck full-bridge inverter
Opis:
This paper proposes a new dc-side active filter for wind generators that combines 12-pulse polygon auto-transformer rectifier with dc-side current injection method and dual-buck full-bridge inverter having not the “shoot-through” problem in conventional bridge-type inverters, and therefore this system with the character low harmonic distortion and high reliability. The proposed dc-side active filter is realized by using dual-buck full bridge converter, which directly injects compensation current at dc-side of two six-pulse diode bridges rectifiers. Compared with the conventional three-phase active power filter at ac-side, the system with the dc-side active filter draws nearly sinusoidal current by shaping the diode bridges output current to be triangular without using the instantaneous reactive power compensation technology, only using simple hysteretic current control, even though under load variation and unbalanced voltage disturbances, and while an acceptable linear approximation to the accurate waveform of injection current is recommended. The performance of the system was simulated using MATLAB/Simulink, and the possibility of the dc-side active filter eliminating current harmonics was confirmed in steady and transient states. The simulation results indicate, the system has a total harmonic distortion of current reduced closely to 1%, and a high power factor on the wind generator side.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 263--277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies