Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power transformer" wg kryterium: Temat


Tytuł:
A Power Transformer as a Source of Noise
Autorzy:
Zawieska, W. M.
Powiązania:
https://bibliotekanauki.pl/articles/90466.pdf
Data publikacji:
2007
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
power transformer
noise reduction
active methods
transformer modeling
rectangular plate vibrations
transformer noise
vibroacoustic analysis
Opis:
This article presents selected results of analyses and simulations carried out as part of research performed at the Central Institute of Labor Protection – the National Research Institute (CIOP-PIB) in connection with the development of a system for active reduction of noise emitted by high power electricity transformers. This analysis covers the transformer as a source of noise as well as a mathematical description of the phenomenon of radiation of vibroacoustic energy through a transformer enclosure modeled as a vibrating rectangular plate. Also described is an acoustic model of the transformer in the form of an array of loudspeakers.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2007, 13, 4; 381-389
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza awaryjności oraz rangi stacji transformatorowych w sieci rozdzielczej SN
The analysis of failures and importance of transformer stations in MV distribution network
Autorzy:
Stasiak, N.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/156787.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stacja transformatorowa SN/nn
awaryjność
ranga w systemie
transformer power station
reliability
importance in the distribution system
Opis:
W pracy omówiono najważniejsze strategie obsługi stacji rozdzielczych SN/nn. Przedstawiono ogólne założenia metody oceny rangi stacji w systemie elektroenergetycznym. Wykonano analizę awaryjności i rangi w systemie 1351 stacji SN/nn. Stwierdzono, że awaryjność głównych elementów wyposażenia stacji nie przekracza 1,5%. Ponad 90% stacji zaliczono do rangi „mało ważna”, a tylko nieco ponad 1% sklasyfikowano jako „strategiczne”.
The paper describes the most important strategies of MV/LV distribution station operation. There are given general ideas of the method for assessment of the importance of the station in a power system. The analysis of failures and importance was performed for 1351 stations. It was found that the failure ratio of main station elements was below 1.5%. The highest value of the failure ratio had MV switches, followed by transformers (approx. 0.7 %). The process of importance assessment was based on the following parameters: the number and power of transformers in a station, the load ratio, a type of the customer of the station, power supply configuration and a type of the station. On this basis over 90% stations were categorized as having “low importance”, while only 1% was found to be “strategic”. The above data suggests changes in the station operation procedures. The currently used TBM strategy should be replaced by the CM strategy. It would lead to lowering the operation costs without significant decrease in the energy supply quality.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 168-171
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza czasowo-częstotliwościowa sygnałów emisji akustycznej generowanych przez podobciążeniowy przełącznik zaczepów o konstrukcji z osobnym wybierakiem i przełącznikiem mocy
Time-frequency analysis of acoustic emission signals generated by on load tap changer constructed from separated selector and power switch
Autorzy:
Cichoń, A.
Frącz, P.
Lorenc., M.
Powiązania:
https://bibliotekanauki.pl/articles/153883.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnosis
acoustic emission method
Opis:
Podobciążeniowe przełączniki zaczepów (PPZ) są jednym z głównych elementów transformatora, który zapewnia możliwość regulacji napięcia w sieci elektroenergetycznej. Ich awarie są częstą przyczyną wyłączeń transformatorów rozdzielczych. W artykule przedstawiono wyniki prac naukowo-badawczych mających na celu scharakteryzowanie sygnałów emisji akustycznej (EA) generowanych przez PPZ o konstrukcji z osobnym wybierakiem i przełącznikiem mocy. Zaletą metody EA jest możliwość wykonywania pomiarów w warunkach normalnej pracy urządzenia. Badania przeprowadzono w warunkach laboratoryjnych. Analizę sygnałów EA przeprowadzono w dziedzinie czasu i czasowo-częstotliwościowej. Ocenę składowych czasowo-częstotliwościowych przeprowadzono z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT) i ciągłej (CWT) transformaty falkowej.
An important part of an electric power transformer is the on load tap changer (OLTC) which enables voltage regulation in the network. Due to high level of failure frequency of these devices, it is necessarily to look for new diagnostic methods which enable their technical state estimation under transformer normal operating conditions. Presently at the Electric Power Institute of the Opole University of Technology there are works in progress aspiring to determine the application possibility of the AE method for OLTC diagnosis. Results of the research works aiming at characterizing the acoustic emission (AE) signals generated by the OLTC constructed from a separated selector and a power switch are presented in the paper. Measurements were taken in a setup with a model of the OLTC type VEL - 110 - 27 from ELIN as the main element. AE signals generated during the whole OLTC joining cycle are presented. Within the signal there were enhanced four characteristic acoustic structures which regard to succeeding stages of the joining process. The AE signals generated by the selector and power switch were analyzed in detail. The analysis of time-frequency components of the signals generated by the OLTC was carried out with the short time Fourier transform (STFT) and con-tinuous wavelet transform (CWT). Based on the comparison of the AE signals generated by the power changer and the selector, two measuring paths endowed with wide band contact transducers were proposed for practical application.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 360-363
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza działania zabezpieczenia podimpedancyjnego dwukadziowego symetrycznego przesuwnika fazowego
Analysis of protection operation under impedance double tank symmetric phase shifting transformer
Autorzy:
Bednarczyk, T.
Halinka, A.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/267229.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
automatyka zabezpieczeniowa
transformator
zakłócenia
Phase Shifting Transformer
power system protection
power transformer
disturbances
Opis:
Zabezpieczenie wykorzystujące kryterium podimpedancyjne stanowi jedno z podstawowych zabezpieczeń jednostek transformatorowych najwyższych napięć (w tym przesuwników fazowych). Zabezpieczenie podimpedancyjne identyfikuje stan pracy chronionego przesuwnika fazowego, sprawdzając położenie końca wektora impedancji wyznaczanej w zabezpieczeniu względem stref pomiarowych zabezpieczenia. Podczas zwarć w obrębie fragmentu sieci objętego ochroną przez zabezpieczenie, koniec wektora impedancji powinien „wchodzić” do stref pomiarowych zabezpieczenia. Wówczas następuje zadziałanie zabezpieczenia i ewentualne wyłączenie przesuwnika fazowego. W artykule zamieszczono wyniki przeprowadzonych badań symulacyjnych warunków działania zabezpieczenia podimpedancyjnego dla dwukadziowego symetrycznego przesuwnika fazowego. W symulacjach uwzględniono szeroki zakres zmian impedancji przesuwnika fazowego, zwarcia wewnętrzne oraz zewnętrzne. Wyniki badań symulacyjnych pozwalają na weryfikację poprawności działania zabezpieczenia podimpedancyjnego przesuwnika fazowego.
Relay protection using criterion under impedance is one of the basic security units high voltage transformer (including phase shifters - PST, ang. Phase Shifting Transformer). Protection under impedance identifies the operating status of the protected PST, checking the position of the end vector impedance to be fixed in terms of securing zones measuring security. While short-circuits within the network portion of the end vector impedance should "enter" zones measuring security. Then followed by a safety device and possible exclusion PST. The article contains the results of the simulation tests of operating conditions for security under impedance doubletransformer tank dwukadziowego symmetric phase shifter. The simulations take into account a wide range of impedance changes PST, short circuit, internal and external. The results of simulation studies allow for verification of correct operation of security under impedance PST.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 71-74
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wyników badań w zakresie oceny stopnia zużycia styków PPZ metodą akustyczną i oscylograficzną
Comparison analysis of research results on determining level of OLTC contact deterioration using acoustic and oscillographic methods of diagnostics
Autorzy:
Cichoń, A.
Bergber, P.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/152504.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnostics
acoustic emission method
Opis:
W artykule przedstawiono wyniki prac naukowo – badawczych związanych z diagnostyką podobciążeniowych przełączników zaczepów (PPZ). Badania wykonano w warunkach laboratoryjnych z wykorzystaniem modelu fizycznego PPZ typu VEL 110, umieszczonego w kadzi wypełnionej olejem izolacyjnym. Sygnały emisji akustycznej rejestrowano szerokopasmowym przetwornikiem piezoelektrycznym przymocowanym do zewnętrznej części kadzi. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej. Wyniki pomiarów metodą oscylograficzną przedstawiono w postaci przebiegów prądowych i wyznaczając wartości czasów własnych. Na podstawie uzyskanych wyników przeprowadzono analizę porównawczą wyników uzyskanych za pomocą obu metod pomiarowych.
This paper presents results of scientific research on diagnostic methods for on load tap changers (OLTC). Measurements were made in laboratory conditions with use of a physical model of the VEL 110 OLTC placed in a tank filled with insulating oil. Acoustic emission signals were recorded with use of a R15α wide band piezoelectric transducer which was fixed to the tank of the model. These signals were analyzed in the time domain, which resulted in calculation of the signal envelope and its characteristic times. The results of the oscillographic measurements are presented in the form of current diagrams and the calculated OLTC characteristic times. Basing on the obtained results of the oscillographic and acoustic measurements, a comparison analysis of both diagnostic methods was performed. The research data presented in this paper proves that detection of OLTC contact deterioration is possible by using both oscillographic and acoustic methods of diagnostics.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 152-155
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy przekładników napięciowych podczas pomiaru napięć odkształconych
Measurements of non-sinusoidal voltages with a voltage transformer
Autorzy:
Kaczmarek, M.
Nowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/155751.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik napięciowy
błąd napięciowy
błąd kątowy
jakość energii
napięcie odkształcone
voltage transformer
voltage error
phase displacement
power quality
non-sinusoidal voltage
Opis:
W ocenie jakości energii elektrycznej ogromne znaczenie mają cechy metrologiczne przekładnika, czyli wartości jego błędów napięciowego i kątowego [1]. W artykule zostały przedstawione zastosowane metody pomiarowe oraz wyniki przeprowadzonych analiz umożliwiające określenie dokładności przekładników napięciowych podczas pomiaru napięć odkształconych. Stwierdzono, że podczas takich pomiarów następuje pogorszenie właściwości metrologicznych przekładników napięciowych, co prowadzi do zmniejszenia ich dokładności przy ocenie jakości energii elektrycznej.
Metrological properties of a measuring transformer such as a voltage error and phase displacement are of significant importance in assessment of electric power quality both in steady and transient state [1]. In the paper the method and results of laboratory investigations of the voltage transformer accuracy during measurements of non-sinusoidal voltages are presented. The laboratory tests based on two medium-voltage transformer models and a voltage transformer of type UDZ 24 produced by ABB company were carried out in the measuring circuit shown in Fig. 1. The measurements were taken in the full range of supply voltages and loads of the secondary winding of the voltage transformers in accordance with the standard for determining the accuracy of the inductive voltage transformers [4]. The voltage error and phase displacement of the voltage transformer determined for measurements of non-sinusoidal voltages, shown in Figs. 2 - 5, were compared with the corresponding errors measured for sinusoidal voltages (presented in Table 1). The influence of the conductive disturbances on the voltage transformer errors was determined as the differences between these values. The results of the laboratory investigations show that the metrological properties of a voltage transformer were worse when it was used for measurements of non-sinusoidal voltages. The increase in errors results in the decrease in the accuracy of the power quality determination. In some cases this worsening of the metrological properties causes the decrease in the voltage transformer accuracy class [4].
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 5-7
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu stopnia zawilgocenia oraz zestarzenia próbek izolacji aramidowo-olejowej na charakterystyki prądu depolaryzacji
Impact analysis of the degree of moisture and aging samples aramid-oil insulation on the depolarization current characteristics
Autorzy:
Wolny, S.
Lepich, M.
Powiązania:
https://bibliotekanauki.pl/articles/154205.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator mocy
ocena stopnia zawilgocenia
ocena stopnia starzenia
polaryzacja
izolacja aramidowo-olejowa
power transformer
assess the degree of moisture
assess the degree of aging
polarization
oil-aramid insulation
Opis:
W artykule zaprezentowano wyniki badań laboratoryjnych wpływu zestarzenia i zawilgocenia izolacji aramidowo-olejowej na prąd depolaryzacji, z uwzględnieniem oddziaływania temperatury na podstawie bezinwazyjnej metody PDC (Polaryzation and Depolaryzation Current). Ponadto w celu wskazania przydatności zastosowanej metody do oszacowania powyższych wskaźników przedstawiono wyniki badań statystycznych odtwarzalności i powtarzalności wykonanych pomiarów.
Results of laboratory research into the influence of ageing and moistness degree of aramid-oil insulation samples on the depolarisation current considering temperature effects are presented. Also the possibilities to apply the non-invasive PDC (Polarisation and Depolarisation Current) diagnostic method to analyse depolarisation currents of the new type of synthetic insulation based on aramid are described. The method of preparation of samples, which differ – in a controlled manner – as to the moistness and ageing degree, is also described. Because of the resulting high repeatability and reproducibility of obtained measurements, this method seems to be appropriate for the diagnosis of solid insulation of power transformers.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 11, 11; 1006-1009
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the effect of characteristic parameters of a distribution transformer on economic management of electric power transmission in low-voltage networks
Autorzy:
Nawrowski, R.
Stein, Z.
Zielińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/97588.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric power transmission
distribution transformer
electrical energy
Opis:
The paper presents an attempt of mathematical description of the effect of, among others, such parameters of modern energetic transformers as magnetizing current or power loss in the core on the power loss and reactive power, in case of power transmission in the distribution networks, particularly of low-voltage.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 299-307
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the effect of exceeding the allowable values of selected parameters of the receivers on operating conditions of a low voltage network
Autorzy:
Nawrowski, R.
Stein, Z.
Zielińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/97549.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
low voltage network
electric power system
degree voltage asymmetry
transformer load asymmetry
synchronous generator
Opis:
Minimum value of the power factor of an electric power network is constrained and its value is determined by the regulations. Customer of electric power is responsible for maintenance of proper value of the power factor. On the other hand, minor electric power customers are not charged with any financial consequences for disregarding proper value of the parameter, in spite of the fact that the distribution companies are charged with the cost of increased power losses. Moreover, the degree of voltage asymmetry of electric power network is constrained and its value is defined by the regulations too. Asymmetry of output voltage of power transformer is caused chiefly by asymmetric loads. The paper presents a proposal of estimating additional power losses caused by reduced value of the power factor and analyzes the effect of various types of load asymmetry on the value of the asymmetry factor. The proposals and analyzes are carried out with the help of Mathcad software.
Źródło:
Computer Applications in Electrical Engineering; 2013, 11; 128-140
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Voltage-regulating and Phaseshifting Transformers to Control Power Flows in the Power System
Wykorzystanie transformatorów z regulacją skośną do sterowania przepływami mocy w systemie elektroenergetycznym
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/397531.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
rozpływ mocy
zespół transformatorowy
regulacja wzdłużno-poprzeczna
active and reactive power flow
regulating transformer
voltage-magnitude-regulating
phase-angle-regulating
Opis:
Transmission system performance results from, among other factors, the use of devices for electricity transmission and transformation. Proper operation and control of these devices allows maintaining proper electricity parameters and the continuous supply to end consumers. In the group of electricity transforming devices transformers can be distinguished by the ability to control both the magnitude and phase angle of voltage. In this way transmission system state parameters are adjusted, which enable selecting the reactive and active power. On the one hand, these are devices of a complex structure, resulting in difficult operating conditions, while on the other hand they provide a potential opportunity to influence the power flow (including active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.
Funkcjonowanie systemu przesyłowego jest wynikiem wykorzystywania pracy m.in. urządzeń służących do przesyłu, jak i transformacji energii elektrycznej. Prawidłowa eksploatacja i sterowanie tymi urządzeniami pozwala na zachowanie właściwych parametrów energii elektrycznej oraz ciągłości zasilania odbiorców końcowych. W grupie urządzeń pozwalających na transformację energii elektrycznej można wyróżnić transformatory z regulacją, które mają możliwość kształtowania zarówno poziomu, jak i kąta napięcia. W ten sposób regulowane są parametry stanu układów przesyłowych pozwalające na dobór przesyłanych wielkości mocy biernej oraz czynnej. Z jednej strony układy te są urządzeniami o skomplikowanej budowie, co wpływa na utrudnione warunki ich eksploatacji, ale jednocześnie z drugiej strony dają one potencjalnie możliwość wpływu na rozpływy mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego, przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
Źródło:
Acta Energetica; 2015, 4; 87-98
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania laboratoryjne wybranych sposobów koordynacji regulatora transformatora blokowego oraz regulatora generatora
Laboratory studies of selected methods of coordination of control of step-up ULTC transformer and multiparameter voltage controller of synchronous generator
Autorzy:
Małkowski, R.
Rink, R.
Kozakowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/268619.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
blok wytwórczy
transformator blokowy
koordynacja regulacji
power generation unit
unit transformer
coordinated voltage control
Opis:
Wprowadzenie wymogu stosowania transformatorów blokowych z przekładnią regulowaną pod obciążeniem spowodowało konieczność określenia właściwego sposobu podziału kryteriów sterowania pomiędzy regulator generatora a regulator transformatora blokowego. W referacie zwrócono uwagę na aspekt miejsca pomiaru napięć. Ma to istotny wpływ zarówno na algorytm jak i jakość regulacji. Rozważania teoretyczne zilustrowane zostały wynikami prób eksperymentalnych.
Introduction of requirement of the use of generator step-up under load tap changing transformers made it necessary to determine the appropriate method of selection control criteria for the synchronous generator voltage control regulator and for the tap changer regulator. A special attention was drawn to the aspect of the point of voltage measurement in the paper. It has crucial impact on control algorithms as well as on the quality voltage control. Theoretical considerations were illustrated with the results of experimental tests.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 57-62
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania oddziaływania akustycznego stacji elektroenergetycznej na środowisko
Research acoustic impact on the environment of the electric power station
Autorzy:
Augustyn, A.
Słaboń, E.
Ślusarek, A.
Powiązania:
https://bibliotekanauki.pl/articles/199185.pdf
Data publikacji:
2015
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
oddziaływanie akustyczne
autotransformator
stacja elektroenergetyczna
ochrona środowiska
acoustic impact
auto-transformer
electric power station
environmental protection
Opis:
W publikacji przedstawiono badania oddziaływania akustycznego stacji elektroenergetycznej na środowisko terenów chronionych oraz koncepcję ograniczania ponadnormatywnej emisji dźwięku. Przedstawiono metodykę rozwiązania problemu emisji dźwięku autotransformatorów do środowiska, obejmującą: pomiary emisji dźwięku, opracowanie numerycznych modeli terenu oraz pokrycia terenu w rejonie autotransformatorów. Określono wpływ głównych źródeł dźwięku na rozkład pola akustycznego na terenach chronionych akustycznie oraz przedstawiono koncepcję zabezpieczeń przeciwhałasowych.
Research of acoustic study of electric power station on the environment for the protected area and the concept of reducing excessive sound emission, are presented. The methodology of solving the problem of auto-transformers sound emission to the environment, including: acoustic measurement, develop digital terrain model and land cover in the area of auto-transformers. The influence of the main sound sources on the distribution of the sound field acoustically protected areas and introduced the concept of protection.
Źródło:
Maszyny Górnicze; 2015, 33, 2; 25-29
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie możliwości regulacji przepływu mocy czynnej w liniach wymiany międzynarodowej
Exploring the possibility of controlling the active power flow in the cross-border tranmission lines
Autorzy:
Ogryczak, T.
Opala, K.
Powiązania:
https://bibliotekanauki.pl/articles/266635.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
Phase Shifting Transformer
active power flow control
cross-border transmission lines
Opis:
W referacie przedstawiono charakterystykę SE Mikułowa, skrócony opis funkcjonalny zastosowanej automatyki oraz wyniki badań działania układu automatycznej regulacji czterech przesuwników fazowych zainstalowanych w liniach wymiany międzynarodowej Mikułowa – Hagenwerder. Badania wykonano w ramach prac uruchomieniowych przesuwników fazowych prowadzonych w SE Mikułowa w 2016 roku. Wyniki te pozwalają zweryfikować rzeczywisty zakres regulacji przepływu mocy czynnej pomiędzy systemem elektroenergetycznym Polski i Niemiec oraz wpływ regulacji na rozpływ mocy czynnej w KSE. Jest to pierwsza tego typu instalacja na połączeniu transgranicznym w Polsce. Zmiana przepływu mocy czynnej z wykorzystaniem przesuwników fazowych nie była dotychczas stosowana w KSE.
The paper presents the characteristics of SE Mikułowa, a brief functional description of applied automation and research results of operation of automation for the four phase shifters installed in the cross-border transmission lines Mikułowa Hagenwerder. Research carried out in the framework of the phase shifters transformers startup conducted in SE Mikułowa in 2016. These results verify the actual range of controlling the active power flow between Polish and German power system and verify control influence on active power flow in Polish national power system. This is the first installation of such type on a cross-border connection in Poland. Changing the active power flow using the phase shifter transformers has not been used in the Polish national power system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 87-90
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Autorzy:
Abbaszadeh, A.
Abedi, M.
Doustmohammadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/140474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arresters
ATP software
ferroresonance
transformer
power system transients
Opis:
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully. One of the disturbances leading to the failure of the riser pole arresters is the ferroresonance overvoltages. In this paper, at first the influence of different transformer simulation models of ATP software on the occurrence of ferroresonance is studied and then the effect of ferroresonance on the riser pole arrester has been scrutinized through the thermal and electrical performance of the arrester in an underground distribution system. The results show that the arrester temperature rises due to energy dissipation in a ferroresonance circumstance, which indeed may result into the explosion of the arrester. Also, applying different models of the transformer in the ATP software and comparing the results, it is shown that the available models do not show the same effect on the arrester.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 717-730
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coordinated control of phase shifting transformers in the power system
Skoordynowane sterowanie przesuwnikami fazowymi w systemie elektroenergetycznym
Autorzy:
Korab, R.
Owczarek, R.
Połomski, M.
Powiązania:
https://bibliotekanauki.pl/articles/397322.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
power system
phase shifting transformer
unscheduled flow
particle swarm optimisation
system elektroenergetyczny
przesuwnik fazowy
przepływ nieplanowy
optymalizacja rojem cząstek
Opis:
In response to the growing problem of unscheduled flows, more and more transmission system operators in Europe provide their systems with phase shifting transformers (PST). However, the operations of several PSTs deployed close to each other must be coordinated for them to be effective and to avoid their harmful interactions. Coordination of a group of such devices leads to a problem of multidimensional optimisation. This paper presents a method of optimal PST setting based on the particle swarm optimisation (PSO) algorithm. As an optimisation criterion the minimization of unscheduled flow through the given system has been applied. The impact of the number of particles in the swarm and their maximum permissible velocity on the optimisation algorithm’s efficiency was analysed. Results are presented for a 118-node test grid.
W odpowiedzi na rosnący problem przepływów nieplanowych coraz większa liczba operatorów systemów przesyłowych w Europie wyposaża swoje systemy w przesuwniki fazowe (PST). Jednakże użycie kilku PST zainstalowanych geograficznie lub elektrycznie blisko siebie musi być skoordynowane w celu skutecznego wykorzystania tych urządzeń i uniknięcia ich niekorzystnych interakcji. Koordynacja grupy takich urządzeń prowadzi do problemu optymalizacji wielowymiarowej. W artykule przedstawiono metodę optymalizacji nastaw PST opartą na algorytmie roju cząstek (PSO). Jako kryterium optymalizacji zastosowano minimalizację przepływu nieplanowego przez dany system. Przeanalizowano wpływ liczby cząstek roju oraz ich maksymalnej dozwolonej prędkości na efektywność algorytmu optymalizacji. Przedstawiono wyniki dla sieci testowej zawierającej 118 węzłów.
Źródło:
Acta Energetica; 2017, 3; 97-103
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies