Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power plant modelling" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Modeling of a supercritical power plant with an oxy type pulverized fuel boiler, a carbon dioxide capture unit and a ‘four-end’ type membrane air separator
Modelowanie elektrowni na parametry nadkrytyczne z kotłem pyłowym typu oxy, instalacją cc oraz membranowym separatorem powietrza typu ‘four-end’
Autorzy:
Kotowicz, J.
Michalski, J.
Powiązania:
https://bibliotekanauki.pl/articles/172908.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modelowanie elektrowni
kocioł oxy
membrana typu four-end
separacja membranowa
elektrociepłownia nadkrytyczna
power plant modelling
oxy boiler
four-end membrane
membrane separation
supercritical power plant
Opis:
W artykule analizowano elektrownie o mocy 600 MW i parametrach pary świeżej 30 MPa/650 °C i wtórnej 6 MPa/670 °C. Elektrownia wyposażona jest w następujące instalacje: kocioł pyłowy typu oxy, wysokotemperaturową membranę do separacji powietrza typu ‘four-end’ oraz instalację przygotowania i sprężania CO2. Wymienione instalacje zostały zamodelowane. Przy założeniu stałej mocy brutto analizowanej elektrowni wyznaczono zapotrzebowanie na moc zamodelowanych instalacjach, sprawność obiegu parowego oraz sprawność termiczną kotła. Wielkości te wyznaczono w funkcji stopnia odzysku tlenu w membranie. Pozwoliło to wyznaczyć sprawność wytwarzania energii elektrycznej netto.
The analysis of a 600 MW supercritical power plant with parameters of life steam at 30 MPa/650 °C and of reheated steam 6 MPa/670 °C was made. Power plant is equipped with the following units: oxy type pulverized fuel boiler, ‘four-end’ high temperature membrane air separator and carbon dioxide capture system which were modeled. With the assumption of a constant gross power of the analyzed power plant, the thermal efficiency of the boiler and the steam cycle efficiency were calculated. These parameters were designated as a function of the recovery rate of oxygen in the air separation unit. This allowed to determine gross and net efficiency of electricity generation.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 73-83
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods for the treatment of common cause failures in redundant systems
Autorzy:
Berg, H. P.
Görtz, R.
Kesten, J.
Powiązania:
https://bibliotekanauki.pl/articles/2069575.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
nuclear power plant
probabilistic safety assessment
simulation
common cause failure
modelling
Opis:
Dependent failures are extremely important in reliability analysis and must be given adequate treatment so as to minimize gross underestimation of reliability. German regulatory guidance documents for PSA stipulate that model parameters used for calculating frequencies should be derived from operating experience in a transparent manner. Progress has been made with the process oriented simulation (POS) model for common cause failure (CCF) quantification. A number of applications are presented for which results obtained from established CCF models are available, focusing on cases with high degree of redundancy and small numbers of observed events.
Źródło:
Journal of Polish Safety and Reliability Association; 2007, 1; 1--8
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of virtual power plant for condition monitoring of power generation unit
Zastosowanie wirtualnej elektrowni do diagnostyki bloku energetycznego
Autorzy:
Barszcz, T.
Powiązania:
https://bibliotekanauki.pl/articles/328806.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
modelowanie
ocena stanu
diagnostyka
energetyka
modelling
condition monitoring
model based diagnostics
power plant
Opis:
The following paper presents the method, called here the Virtual Power Plant (VPP), for the condition monitoring of power generation unit elements. The Virtual Power Plant is the proposal of a group of computers, which model a real power plant unit in the real time. This paper is focused on Virtual Power Plant architecture and procedure to use it for condition monitoring. Such a procedure is based on models of various types tuned to the normal technical state of the plant. Next, this model is used to detect any changes in the behaviour of the plant elements. The paper present details of the Virtual Power Plant idea: its structure and functionality of key elements. The structure of the model is presented with stress on its modularity and flexibility. Next part of the paper is the case study, where test installation, tuned to a 200MW coal fired unit, was described. Results from operation on the test installation are presented.
Artykuł przedstawia metodę, nazwaną Wirtualną Elektrownią (VPP, ang. Virtual Power Plant), zastosowana do oceny stanu elementów bloku energetycznego. VPP jest propozycją zastosowania zespołu komputerów, które będą modelować pracę bloku energetycznego w czasie rzeczywistym. Artykuł koncentruje się na przedstawieniu architektury Wirtualnej Elektrowni oraz na jej zastosowaniu do oceny stanu technicznego. Metoda opiera się na heterogenicznym modelu, dostrojonym do bloku energetycznego w poprawnym stanie technicznym. Następnie model ten jest podstawą wykrywania zmian zachowania elementów bloku. Artykuł przedstawia szczegóły koncepcji Wirtualnej Elektrowni: jej strukturę oraz główne elementy. Opisano model bloku ze szczególnym naciskiem na modułowość i elastyczność. W kolejnej części artykułu opisano instalację testową, gdzie VPP została dostrojona do rzeczywistego bloku typu 200MW. Zaprezentowano wyniki pracy instalacji.
Źródło:
Diagnostyka; 2007, 4(44); 91-98
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model-based evaluation of a power plant steam boiler system
Ocena efektywności pracy kotła parowego w elektrowni węglowej
Autorzy:
Barszcz, T.
Czop, P.
Bednarz, J.
Powiązania:
https://bibliotekanauki.pl/articles/257537.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
elektrownia cieplna
kocioł parowy
modelowanie
identyfikacja układów
MATLAB
Simulink
power plant
steam boiler
modelling
system identification
Opis:
The method, involving the combination of first-principle and data-driven approaches towards assessing efficiency and diagnosing steam boilers, is presented in this paper. The objectives of this work are as follows: (i) to implement a moderately complex first-principle model of a steam boiler to reproduce operational measurements in real-time simulations, (ii) to develop a tuning method for this model, (iii) to propose key indicators of heater performance using a model-based approach, and finally (iv) to automate the calculation process of the indicators. The paper discusses a nonlinear least-square optimisation technique used to adjust the phenomenological parameters of the model. The model variables and estimated parameter values were used to formulate performance indicators intended for a model-based evaluation approach. The validation was successfully performed using operational data from a 225 MW coal-fired power unit.
W artykule przedstawiono metodę oceny efektywności pracy kotła parowego. Proponowana metoda umożliwia również diagnostykę kotłów parowych w elektrowniach węglowych. Metodologia zaproponowana w artykule umożliwia wyznaczenie fizycznych parametrów kotła parowego w celu analizy jego wydajności za pomocą kluczowych wskaźników procesu. Cele tej pracy są następujące: (i) zbudowanie modelu kotła parowego do odtworzenia pomiarów eksploatacyjnych w symulacji w czasie rzeczywistym, (ii) opracowanie metody strojenia dla tego modelu, (iii) zaproponowanie kluczowych wskaźników wydajności podgrzewacza za pomocą podejście opartego na modelu, a na końcu (iv) zautomatyzowanie procesu obliczania wskaźników. W artykule omówiono technikę optymalizacji z wykorzystaniem nieliniowej metody najmniejszych kwadratów, która została wykorzystana do dostrojenia parametrów modelu. Zmienne modelu oraz szacunkowe wartości jego parametrów zostały wykorzystane do opracowania wskaźników oceny wydajności kotła opartych na zbudowanym modelu. Walidację modelu przeprowadzono dla danych eksploatacyjnych zarejestrowanych w 225 MW bloku elektrowni węglowej.
Źródło:
Problemy Eksploatacji; 2011, 2; 7-19
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of the influence of wind power plants on the compartments of the complex landscape system
Autorzy:
Ruda, Mariia
Boyko, Taras
Chayka, Oksana
Mikhalieva, Maryna
Holodovska, Olena
Powiązania:
https://bibliotekanauki.pl/articles/2073738.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
eco-indicator
ecological profile
environmental impact assessment
harmful factors
simulation modelling
waste management
wind power plant
wind turbine
Opis:
The impact of wind power plants on the environmental components is assessed taking into account a number of their parameters, in particular the technical characteristics of wind turbines, the characteristics of networks, engineering and other structures. To do this the life cycle of the wind power plants is described taking into account (by way of inventory) all the necessary materials and resources. Waste management scenarios have been developed, the use of which will make it possible to reduce the harmful impact on the environment. Based on the inventory and input data on the wind farm under study, a diagram is generated - a tree of life cycle processes of the wind power plant - to determine the potential environmental impacts. A list of impact categories that represent the load on the environment caused by the wind power plant is defined; also, the relative contribution of harmful factors is determined for each category, taking into account possible scenarios of waste management. Ecological profiles have been built for all potential impacts on the environment. After normalisation and determination of significance, individual estimates of all indicators and their distribution in three categories of lesions were obtained: human health, ecosystem quality and resources, as well as four stages of the wind farm life cycle: production, dismantling and disposal, operation, transportation and installation. The obtained profiles made it possible to determine individual indicators and eco-indicators, expressed in eco-points that characterise the wind farm under study.
Źródło:
Journal of Water and Land Development; 2022, 52; 156--165
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849273.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A mathematical model of two-stage Solid Oxide Fuel Cell, SOFC, stacks for dynamic simulation of Combined Heat and Power system fed by natural gas
Autorzy:
Palus, Mateusz
Pianko-Oprych, Paulina
Powiązania:
https://bibliotekanauki.pl/articles/1849268.pdf
Data publikacji:
2021
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
dynamic model
natural gas
Solid Oxide Fuel Cell stacks
Combined Heat and Power
CHP
system
Balance of Plant
BoP
modelling
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
Opis:
Zero-dimensional two-stage SOFC stacks dynamic model was developed to investigate the effect of operating parameters on stacks performance. The model resolves spatially thermal and thermo-electrochemical behaviour for electrochemical reactions, Catalytic Partial Oxidation and Steam Reforming processes. Design variables and thermo-electrochemical properties were obtained from in-house-fabricated SOFCs carried out by project partners. The completed SOFCs based Combined Heat and Power, CHP, system model was validated by data18 and numerical results obtained at steady-state mode showing its high-fidelity. A parametric study with respect to key operating parameters including changes in fuel utilization, lambda number and current density values was conducted. The global CHP system dynamic response, in term of the current/voltage delivered by two-stage SOFC stacks, under a fi xed fuel utilization, has been determined resulting in greater variations in the voltage of a single cell in the first stack in comparison to the corresponding values in the second stack.
Źródło:
Polish Journal of Chemical Technology; 2021, 23, 2; 1-11
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of a serial connection of two staged SOFC stacks in a CHP system fed by methane using Aspen TECH
Autorzy:
Pianko-Oprych, Paulina
Palus, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/779502.pdf
Data publikacji:
2019
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Solid Oxide Fuel Cell stacks
Combined Heat and Power system
Balance of Plant
BoP
modelling
methane
Catalytic Partial Oxidation
CPOx
reformer
steam reformer
part and full load
steady state
dynamic model
Opis:
The objective of the study was to develop a steady-state system model in Aspen TECH using user-defined subroutines to predict the SOFC electrochemical performance. In order to achieve high overall fuel utilization and thus high electrical efficiency, a concept of Combined Heat and Power system with two-stage SOFC stacks of different number of cells was analyzed. The concept of two-stage SOFC stacks based system was developed in the framework of the FP7 EU-funded project STAGE-SOFC. The model was validated against data gathered during the operation of the proof-of-concept showing good agreement with the comparative simulation data. Following model validation, further simulations were performed for different values of fuel utilization to analyze its influence on system electrical performance. Simulation results showed that the concept of two-stage SOFC stacks configuration was viable and reliable. The model can be useful for development the optimal control strategy for system under safe conditions.
Źródło:
Polish Journal of Chemical Technology; 2019, 21, 1; 33-43
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie wybranych procesów logistycznych w elektrociepłowni
The model of supply coal process at the power plant
Autorzy:
Krajewska, R.
Łukasik, Z.
Powiązania:
https://bibliotekanauki.pl/articles/314732.pdf
Data publikacji:
2017
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
pocesy zaopatrzenia w węgiel opałowy
zarządzanie łańcuchem dostaw
modelowanie procesów logistycznych
elektrociepłownia
logistyka elektrociepłowni
procurement processes in coal fuel
supply chain management
modelling in logistics processes
power plant
CHP logistics
Opis:
Planowanie procesów logistycznych w elektrociepłowni jest dużym wyzwaniem stojącym przed przedsiębiorstwami energetycznymi, które podlegają tym samym prawom gospodarki magazynowej, co przedsiębiorstwa produkcyjne czy handlowe. Dodatkowym elementem, który ma wpływ na te procesy jest odpowiedni poziom zapasów, który ma gwarantować odpowiedni poziom bezpieczeństwa energetycznego. W artykule omówiono jeden z wybranych procesów logistycznych, który ma decydujący wpływ na zapewnienie ciągłości dostaw ciepła i energii elektrycznej odbiorcom. Przedstawiono dwa modele procesu zaopatrzenia elektrociepłowni w węgiel opałowy. Pierwszy model (MBD) uwzględnia rzeczywiste procedury stosowane w wybranej elektrociepłowni podczas procesu zaopatrzenia w węgiel opałowy. Opisuje on sposób planowania zużycia opału, a także zasady planowania i zamawiania opału na podstawie dokumentów uzyskanych z elektrociepłowni. Drugi przedstawiony model to model, który został wykorzystany w procesach symulacyjnych pozwalających zoptymalizować procedury zaopatrzenia elektrociepłowni w węgiel.
Planning of the logistics processes in CH plants is a big challenge, because energy companies are subject to the same laws of warehouse management, as manufacturing companies or commercial businesses. An additional element which has an impact on the level of stocks in companies of this industry is energy security, which is necessary to ensure the continuity of supplying heat and electricity for demand from customers. Paper presents two models of the process coal fuel supplying in power plants. The first model (MBD) reflects real procedures used in a selected power plant during the supply of coal fuel. It describes how to plan the consumption of fuel, as well as the rules and ordering of fuel, which is based on the documents obtained from CHP plants. The second presented model is a model that has been used in a simulation whose aim is to optimize procedures of supplying power plants in coal.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2017, 18, 12; 1529-1534, CD
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies