Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power flow" wg kryterium: Temat


Tytuł:
Application of the matrix converter to power flow control
Autorzy:
Szcześniak, P.
Fedyczak, Z.
Powiązania:
https://bibliotekanauki.pl/articles/141546.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
matrix converter
AC systems
power flow
Opis:
Advanced power electronic converters can provide the means to control power flow and ensure proper and secure operation of the future power grid. The small electrical energy sources dispersed in electrical power systems referred to as distributed generation are one of the most significant parts of future grids - Smart Grids. The threephase, direct matrix converter is an alternative solution to the conventional AC-DC-AC converter for interfacing two AC systems in distributed power generation with different voltage and/or frequency parameters. This paper presents a control analysis of a threephase matrix converter employed as a power interface of future electrical grids. The proposed system has been successfully tested for bidirectional power flow operation with different grid operating conditions, such as, frequency and voltage variation.
Źródło:
Archives of Electrical Engineering; 2014, 63, 3; 409-422
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Investigations of the Upqc Arrangement
Autorzy:
Benysek, G.
Powiązania:
https://bibliotekanauki.pl/articles/262602.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power quality
power flow control
harmonics compensation
reactive power compensation
Opis:
This paper presents the fundamental properties and dependences describing the UPQC (Unified Power Quality Conditioner) arrangements. The UPQC devices simultaneously permit to fulfill the following functions: voltage and current harmonics compensation, network voltage and load current symmetrization as well as network voltage stabilization and power flow control. The selected results of the experimental investigations conducted on the small power laboratory model have been described. Applied method for DC link capacity selection was talked over in details and confirmed with experimental results. Results of experimental investigations, including operation of the UPQC arrangement in case of thyristor rectifier load were also introduced.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 1; 27-34
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of a power transmission system under uncertain load conditions and network configurations
Autorzy:
Zio, E.
Piccinelli, R.
Delfanti, M.
Olivieri, V.
Pozzi, M.
Powiązania:
https://bibliotekanauki.pl/articles/2069672.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
vulnerability
electric power transmission network
load flow
power flow betweenness centrality
uncertainty
Opis:
In this paper, the load flow problem in a power transmission network is studied in presence of load and Power generation uncertainties and transmission lines failures. Network performance indicators are computed and the importance of the different components is evaluated by a power flow betwenness centrality measure.
Źródło:
Journal of Polish Safety and Reliability Association; 2010, 1, 1; 279--284
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single-objective optimal power flow for electric power systems based on crow search algorithm
Autorzy:
Fathy, A.
Abdelaziz, A.
Powiązania:
https://bibliotekanauki.pl/articles/140618.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
crow search algorithm
distribution network
optimal power flow
Opis:
This paper presents the application of a recent meta-heuristic optimization technique named a crow search algorithm (CSA) in solving the problem of an optimal power flow (OPF) for electric power systems. Various constrained objective functions, total fuel cost, active power loss and pollutant emission are proposed. The generators’ output powers, generators’ terminal voltages, transmission lines’ taps and the shunt capacitors’ reactive powers are considered as variables to be designed. The proposed methodology based on the CSA is applied on an IEEE 30-bus system and IEEE 118-bus system. The obtained results via the CSA are compared to others and they ensure the superiority of the CSA in solving the OPF problem in electric power systems.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 123-138
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New approaches for the identification of influential and critical nodes in an electric grid
Autorzy:
Adebayo, Isaiah
Sun, Yanxia
Powiązania:
https://bibliotekanauki.pl/articles/2135727.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
centrality measures
critical nodes
influential nodes
power flow
power system
Opis:
The aftermath of including new technologies in a modern electric system in conjunction with the incessant rise in power demand could pose a risk to the optimal operation of the system. Therefore, it becomes imperative to identify the most influential and critical nodes of such a system to avert future problems in network operation. In this paper, to identify most significant nodes of the system, the authors propose two measures of centrality in accordance with the network structural properties of a power system, namely, degree centrality (DC) and eigenvector centrality (EC). These are expressed considering the admittance matrix that exists among the interconnection of load to load nodes in an electrical power network. A critical node closeness centrality (CNCC) method is also proposed to identify critical nodes of the system. This is done by modifying the conventional closeness centrality (CC) to include the influence of interconnection that exists between network load to load nodes as captured by the admittance matrix between them. A comparative analysis of the proposed techniques with other conventional methods is also carried out. The result of the simulation shows that the proposed methods could serve as alternative tools in the identification of influential and weak nodes in a power system.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 671--686
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power flow analysis and control of distributed FACTS devices in power system
Autorzy:
Anand, V.
Mallik, S. K.
Powiązania:
https://bibliotekanauki.pl/articles/141190.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
D-FACTS
UPFC
power flow control
stability
THD
FACTS
Opis:
The deployment of a distributed power-flow controller (DPFC) in a single- machine infinite-bus power system with two parallel transmission lines are considered for the analysis in this paper. This paper presents the network analysis of the DPFC for power flow control. The performance is evaluated on a given test system with a single line-to- ground fault. The improvement in the stability as well as power quality is evident from the results. Thus the DPFC has the ability to enhance the stability and power quality of the system.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 545--561
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal location of interline power flow controller in a power system network using ABC algorithm
Autorzy:
Sreejith, S.
Psimon, S.
Selvan, M.P.
Powiązania:
https://bibliotekanauki.pl/articles/141232.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
IPFC
power injection model
power flow control
ABC algorithm
cost minimization
Opis:
This paper proposes a methodology based on installation cost for locating the optimal position of interline power flow controller (IPFC) in a power system network. Here both conventional and non conventional optimization tools such as LR and ABC are applied. This methodology is formulated mathematically based on installation cost of the FACTS device and active power generation cost. The capability of IPFC to control the real and reactive power simultaneously in multiple transmission lines is exploited here. Apart from locating the optimal position of IPFC, this algorithm is used to find the optimal dispatch of the generating units and the optimal value of IPFC parameters. IPFC is modeled using Power Injection (PI) model and incorporated into the problem formulation. This proposed method is compared with that of conventional LR method by validating on standard test systems like 5-bus, IEEE 30-bus and IEEE 118-bus systems. A detailed discussion on power flow and voltage profile improvement is carried out which reveals that incorporating IPFC into power system network in its optimal location significantly enhance the load margin as well as the reliability of the system.
Źródło:
Archives of Electrical Engineering; 2013, 62, 1; 91-110
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power flow controller based on bipolar direct PWM AC/AC converter operation with active load
Autorzy:
Kaniewski, Jacek Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/141487.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power flow controller
direct AC/AC converter
matrix chopper
power quality
Opis:
The uncontrolled power flow in the AC power system caused by renewable energy sources (restless sources, distributed energy sources), dynamic loads, etc., is one of many causes of voltage perturbation, along with others, such as switching effects, faults, and adverse weather conditions. This paper presents a three-phase voltage and power flow controller, based on direct PWM AC/AC converters. The proposed solution is intended to protect sensitive loads against voltage fluctuation and problems with power flow control in an AC power system. In comparison to other solutions, such as DVR, UPFC, the presented solution is based on bipolar matrix choppers and operates without a DC energy storage unit or DC link. The proposed solution is able to compensate 50% voltage sags, in the case of three-phase symmetrical voltage perturbation, and single phase voltage interruptions. Additionally, by means of a voltage phase control with a range of 60◦ in each phase, it is possible to control the power flow in an AC power system. The paper presents an operational description, a theoretical analysis based on the averaged state space method and four terminal descriptions, and the experimental test results from a 1 kVA laboratory model operating under active load.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 341-356
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal power flow with transmission cost solution under bilateral and multilateral transactions
Autorzy:
Bastin Solai Nazaran, J.
Selvi, K.
Powiązania:
https://bibliotekanauki.pl/articles/141690.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
SEOPF
ESCOPF
power flow tracing
severity index
HGO
bilateral
multilateral transactions
Opis:
In a deregulated electricity market, it is important to dispatch the generation in an economical manner and to ensure security under different operating conditions. In this study evolutionary computation based solution for optimal power flow is attempted. Social welfare optimization is taken as the objective function, which includes generation cost, transmission cost and consumer benefit function. Transmission cost is calculated using Bialek’s power flow tracing method. Severity index is applied as a constraint to measure the security. The objective function is calculated for pre and post contingency periods. Real power generations, real power loads and transformer tap settings are selected as control variables. Different bilateral and multilateral conditions are considered for analysis. A Human Group Optimization algorithm is used to find the solution of the problem. The IEEE 30 bus system is taken as a test system.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 227-245
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja zbocznikowania dławikiem przesuwnika fazowego na granicy polsko-niemieckiej
The concept of shifting with the induction coil of the phase shift transmitter at the polish-german border
Autorzy:
Szubert, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2031418.pdf
Data publikacji:
2021
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
FACTS
PST
IPC
sterowanie przepływem mocy
zakłócenia
power flow control
disturbance
Opis:
W artykule przeanalizowano wpływ sterowników FACTS (PST oraz IPC) na pracę połączenia transgranicznego Polska-Niemcy. Stwierdzono, że przesuwnik fazowy PST spełnia podstawowe wymagania i tylko w niewielkim stopniu wpływa na automatykę zabezpieczeniową. Jego rozbudowa do układu międzyfazowego sterownika mocy IPC umożliwiłaby dodatkowo odcięcie się od zakłóceń pochodzących z niemieckiego systemu, jednakże wymagałaby istotnych zmian w automatyce zabezpieczeniowej.
Unplanned energy flow from Germany via Poland to the Czech Republic caused overheating of transmission lines in the west of our country. In order to prevent the necessity to switch off these lines, phase shift transformers (PST) were placed on the border. However, the German system is highly saturated with wind electricity and therefore difficult to steer, which makes it a source of interference for neighbouring countries. The article analyses the impact of flexible AC transmission system (FACTS) drivers on the operation of the Poland-Germany cross-border electrical connection. It was found that the PST meets the basic requirements and has only a slight influence on the protection automatics. Expanding it to the interphase power controller (IPC) would additionally cut off the interference from the German system, however, it would require profound changes in the protection automatics.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2021, 73; 57-60
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-objective optimal reactive power dispatch to maximize power system social welfare in the presence of generalized unified power flow controller
Autorzy:
Suresh, C. V.
Sivanguraju, S.
Powiązania:
https://bibliotekanauki.pl/articles/141441.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
generalized unified power flow controller
optimal reactive power dispatch
social welfare
multi-objective optimization
Opis:
In this paper a novel non-linear optimization problem is formulated to maximize the social welfare in restructured environment with generalized unified power flow controller (GUPFC). This paper presents a methodology to optimally allocate the reactive power by minimizing voltage deviation at load buses and total transmission power losses so as to maximize the social welfare. The conventional active power generation cost function is modified by combining costs of reactive power generated by the generators, shunt capacitors and total power losses to it. The formulated objectives are optimized individually and simultaneously as multi-objective optimization problem, while satisfying equality, in-equality, practical and device operational constraints. A new optimization method, based on two stage initialization and random distribution processes is proposed to test the effectiveness of the proposed approach on IEEE-30 bus system, and the detailed analysis is carried out.
Źródło:
Archives of Electrical Engineering; 2015, 64, 3; 405-426
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie możliwości przesyłowych dwóch układów regulacyjnych: transformatorów z regulacją poprzeczną oraz transformatorów z regulacją wzdłużną
A comparison transmission capacity of two regulation transformers with quadrature regulation and in-phase regulation
Autorzy:
Sarnicki, M.
Zajczyk, R.
Tarakan, B.
Tarakan, K.
Powiązania:
https://bibliotekanauki.pl/articles/267801.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
regulacja przepływu mocy biernej
regulacja kąta mocy
transformator dodawczy
Phase Shifter
active power flow control
reactive power flow control
power angle
booster transformer connections
Opis:
Poniższy artykuł przedstawia możliwość regulacji mocy czynnej i biernej przepływającej pomiędzy podsystemami elektroenergetycznymi. Do regulacji przepływów wykorzystano przesuwnik fazowy i transformator dodający napięcie w fazie. Zilustrowana została regulacja mocy czynnej i biernej w badanym systemie elektroenergetycznym. Istotna jest zależność regulacji danej mocy od układu połączeń strony SN transformatora dodawczego (czy układ działa, jako przesuwnik czy jako transformator dodający napięcie w fazie).
This paper describes the regulation of active and reactive power between the subsystems in larger power system. To regulate the flow were used phase shifters and booster transformer which adds voltages in phase. The regulation of the active power and reactive in considered power system was shown in this article. Important is the way to regulate a certain kind of power (active or reactive), which strongly depends of MV side connections of booster transformer (whether the system acts as a phase shifter or as a transformer which adds the voltage in phase).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 89-91
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New Multiphase Matrix Converter Based Device for Power Flow Control
Nowoczesne urządzenia do kontroli rozpływu mocy w systemie elektroenergetycznym oparte na wielofazowym przekształtniku macierzowym
Autorzy:
Szczepanik, J.
Sieńko, T.
Powiązania:
https://bibliotekanauki.pl/articles/397265.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
FACTS
matrix converter
power flow control
przekształtnik macierzowy
kontrola rozpływu mocy SEE
Opis:
The article presents the concept of new matrix converter (MC) based device working as a phase shifting control device in a power system. The multiphase MC is working under an innovative control algorithm specially dedicated to the proposed application. The work presents the results of the simulation of the MC work in this application as well as the analysis of the MC properties.
Autorzy artykuły prezentują koncepcję konstrukcji przesuwnika fazowego, zbudowanego z wykorzystaniem przekształtnika macierzowego (ang. matrix converter, MC) ze specjalnie opracowanym na potrzeby tego urządzenia algorytmem kontroli. Przedstawiają również wyniki prób symulacyjnych, pokazujących wpływ urządzenia na rozpływ mocy w prostym systemie elektroenergetycznym (SEE).
Źródło:
Acta Energetica; 2013, 4; 158-171
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvisation process for banks capacitor compensation applied fuzzy logic knowledge for nodal detection on electrical network
Autorzy:
Gasbaoui, B.
Oudda, M.
Nasri, A.
Powiązania:
https://bibliotekanauki.pl/articles/384634.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
capacitor placement
fuzzy logic
Harmony Search Optimization (HSO)
capacitor seizing
power flow
Opis:
The main problem of electrical distribution systems is the reactive power flow. It causes reduction of active power transmission, diminishes power losses, and augments the drop voltage. In this research we described an efficiency approach FLC-HSO to solve the optimal power flow (OPF) combinatorial problem. The proposed approach employ tow algorithms, Fuzzy logic controller (FLC) algorithm for nodal detection and harmony search optimization (HSO) algorithm for optimal seizing capacitor of OPF combinatorial problem control variables. HSO method is more proficient in improving combinatory problem. The proposed approach has been examined and tested on the standard IEEE 57-bus test system with different objectives that reflect cost function minimization, voltage profile improvement, and voltage stability enhancement. The proposed approach results have been compared to those that reported in the literature recently. The results are promising and show the effectiveness and robustness of the proposed approach.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2011, 5, 4; 11-16
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
HELM - nowa metoda obliczania rozpływów mocy w sieciach elektroenergetycznych
HELM - new method for the power flow calculation in electric power grids
Autorzy:
Wędzik, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/266889.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rozpływy mocy
metoda HELM
analiza zespolona
power flow
HELM method
Complex analysis
Opis:
Metoda HELM (Holomorphic Embedding Load Fload Method) jest całkowicie nową metodą rozwiązywania równań opisujących stany ustalone systemów elektroenergetycznych. Działanie metody oparte jest o wykorzystanie technik analizy zespolonej. Jednak najważniejszą jej cechą jest to, że jeżeli rozwiązanie istnieje, wówczas odpowiada rzeczywistemu stanowi pracy systemu. Natomiast gdy rozwiązanie nie istnieje, wówczas jednoznacznie sygnalizuje że wystąpi lawina napięcia (blackout). Artykuł jest pierwszą prezentacją metody HELM. Pokazuje jej główne założenia i sposób odwzorowania podstawowych elementów modelu systemu elektroenergetycznego. Dokonuje również porównania obliczeń z wykorzystaniem metody HELM z klasycznymi metodami iteracyjnymi.
HELM (Holomorphic Embedding Load Flow Method) is a novel method for calculation the power flow equations of power systems. It based on the techniques of Complex Analysis. HELM is non-iterative and deterministic method, yielding the correct solution when it exists and, conversely, unequivocally signaling voltage collapse when it does not. The article is the first presentation of the HELM method. It shows its main assumptions and the way of creation the basic elements of the power system model. Author compares the calculations using the HELM method with classic iterative methods.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 33-36
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sound Radiation from a Roundabout
Autorzy:
Piddubniak, O.
Piddubniak, N.
Powiązania:
https://bibliotekanauki.pl/articles/177962.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
roundabout
car sound radiation
stationary phase method
acoustic pressure
power flow density
Opis:
Sound propagation from the vehicles moving on the city roundabout, with taking into account the wind is investigated. Solution of the problem for one moving sound source is found by means of the integral Fourier transforms extended over space variables and time. Inverse transforms are calculated approximately, using a stationary phase method and iterative technique. The solution for a general problem is obtained as a superposition of many partial solutions. The numerical analysis of noise characteristics is performed for the three-way Korfanty roundabout case in Łódz.
Źródło:
Archives of Acoustics; 2010, 35, 3; 437-456
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia kompensacji mocy biernej w sieci dystrybucyjnej
Selected problems of the reactive power compensation in distribution networks
Autorzy:
Kulig, S.
Bąchorek, W.
Brożek, J.
Powiązania:
https://bibliotekanauki.pl/articles/266726.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci elektroenergetyczne
kompensacja mocy biernej
rozpływy mocy
electric power networks
reactive power compensation
load model
power flow
Opis:
Przesył mocy biernej w sieci elektroenergetycznej jest niezbędny do funkcjonowania urządzeń zasilanych napięciem przemiennym jednak wpływa on niekorzystne na parametry jej pracy. Jednym ze sposobów ograniczenia tego wpływu jest instalacja urządzeń do kompensacji mocy biernej. Moc tych urządzeń ustalana jest najczęściej na podstawie obciążenia szczytowego sieci, tak aby spełnione zostały wymagania w zakresie dyrektywnego współczynnika mocy tg. Często moc takich źródeł mocy biernej jest stała, z zatem nie jest dostosowywana do zmian obciążenia sieci. W dolinie obciążenia przy braku tzw. kompensacji nadążnej może wystąpić problem przekompensowania co wpływa na poziomy napięć sieci zasilających. W artykule przedstawia się wybrane problemy kompensacji mocy biernej w sieci dystrybucyjnej. Przedstawiono przykłady i wyniki analiz ilustrujące wpływ sposobu kompensacji mocy biernej w sieci rozdzielczej na warunki pracy sieci elektroenergetycznej.
In the paper, the selected problems of reactive power compensation in a distribution network are presented. Reactive power is indispensable for a proper functioning of alternating current devices. The negative influence of the transfer of reactive power on the working of an electric power system makes the electric power operators to reduce its consumption by determining the required value of the directive power factor in the consumer’s network. In order to meet the value of the directive factor, the consumers compensate the reactive power. If they decide to use the reactive power compensator for peak loads, it is likely that overcompensation will take place at low loads. In such cases, the load becomes a receiver of the reactive power. Such a load results in the increased voltage at the connection point even above the admissible levels. In the paper, the influence of the direction of change in the reactive power flow on the levels of voltage in an electric power system is analyzed.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 36; 127-130
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowoczesne urządzenia do kontroli rozpływu mocy w systemie elektroenergetycznym oparte na wielofazowym przekształtniku macierzowym
New multiphase matrix converer based device for power flow control
Autorzy:
Szczepanik, J.
Sieńko, T.
Powiązania:
https://bibliotekanauki.pl/articles/269062.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
FACTS
przekształtnik macierzowy
kontrola rozpływu mocy w SEE.
Matrix Converter
Power Flow Control
Opis:
Artykuł prezentuje koncepcję konstrukcji przesuwnika fazowego zbudowanego w oparciu o przekształtnik macierzowy (MC – matrix converter) ze specjalnie opracowanym na potrzeby tego urządzenia algorytmem kontroli. W artykule zawarto również wyniki prób symulacyjnych pokazujących wpływ urządzenia na rozpływ mocy w prostym Systemie Elektroenergetycznym - SEE.
The article presents the concept of new matrix converter (MC) based device working as a phase shifting control device in power system. The multiphase MC is working under innovative control algorithm specially dedicated for the proposed application. The work presents the results of the simulation of the MC work in this application as well as the analysis of the MC properties.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 83-86
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości wykorzystania metody punktu wewnętrznego do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym
Interior point method evaluation for reactive power flow optimization in the power system
Autorzy:
Lubośny, Z.
Dobrzyński, K.
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/267231.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
optymalizacja rozpływu mocy biernej
metoda punktu wewnętrznego
reactive power flow optimization
interior point method
Opis:
W referacie poddano weryfikacji metodę punktu wewnętrznego pod kątem jej wykorzystania do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym. Rozważania przeprowadzono na 28 węzłowym systemie CIGRE, z wykorzystaniem zaimplementowanej metody punktu wewnętrznego w programie Power Factory firmy DIgSILENT.
The paper verifies an interior point method for reactive power flow optimization in the power system. The study was conducted on 28 node CIGRE system, using the interior point method optimization procedures implemented in Power Factory software.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 31-34
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja rozpływu mocy w systemie elektroenergetycznym z zastosowaniem nowoczesnych algorytmów optymalizacji interior point oraz non interior point
Optimal power flow by using modern interior point and non interior point optimization algorithms
Autorzy:
Połomski, M.
Baron, B.
Powiązania:
https://bibliotekanauki.pl/articles/268086.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
optymalizacja rozpływu mocy
non interior point
optimal power flow
interior point
non-interior point
Opis:
W artykule zaprezentowano algorytm prymalnodualnej metody punktu wewnętrznego oraz nowy wariant metody optymalizacji non interior point w zastosowaniu do zadania optymalizacji rozpływu mocy w systemie elektroenergetycznym (OPF). Opisane algorytmy zostały zaimplementowane w autorskim oprogramowaniu. Przeprowadzone eksperymenty obliczeniowe wskazują przydatność zaimplementowanych algorytmów w zakresie wyznaczenia rozwiązania zadania OPF, w tym dla modelu systemu o rozmiarach porównywalnych z rozmiarami Krajowego Systemu Elektroenergetycznego.
The idea of optimal power flow (OPF) is to determine the optimal settings for control variables while respecting various constraints, and in general it is related to power system operational and planning optimization problems. Vast number of optimization methods have been applied to solve the OPF problem, but their performance is highly dependent on the size of a power system being optimized. The development of the OPF recently has tracked significant progress both in numerical optimization techniques and computer techniques application. In recent years, application of interior point methods to solve OPF problem has been paid great attention. This is due to the fact that IP methods are among the fastest algorithms, well suited to solve large-scale nonlinear optimization problems. This paper presents the primal-dual interior point method based optimal power flow algorithm and new variant of the non-interior point method algorithm with application to optimal power flow problem. Described algorithms were implemented in custom software. The experiments show the usefulness of computational software and implemented algorithms for solving the optimal power flow problem, including the system model sizes comparable to the size of the National Power System.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 32; 35-38
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiobjective Improved Particle Swarm Optimisation for Transmission Congestion and Voltage Profile Management using Multilevel UPFC
Autorzy:
Rao, Mallavolu Malleswara
Ramadas, Geetha
Powiązania:
https://bibliotekanauki.pl/articles/1193696.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
congestion
unified power flow controller
improved particle swarm optimization
modular multilevel converter
voltage profile
Opis:
This paper proposes a multiobjective improved particle swarm optimisation (IPSO) for placing and sizing the series modular multilevel converter-based unified power flow controller (MMC-UPFC) FACTS devices to manage the transmission congestion and voltage profile in deregulated electricity markets. The proposed multiobjective IPSO algorithm is perfect for accomplishing the close ideal distributed generation (DG) sizes while conveying smooth assembly qualities contrasted with another existing algorithm. It tends to be reasoned that voltage profile and genuine power misfortunes have generous upgrades along ideal speculation on DGs in both the test frameworks. The proposed system eliminates the congestion and the power system can be easily used to solve complex and non-linear optimisation problems in a real-time manner.
Źródło:
Power Electronics and Drives; 2019, 4, 39; 79-93
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cuckoo search algorithm for optimal placement and sizing of static var compensator in large-scale power systems
Autorzy:
Nguyen, K. P.
Fujita, G.
Dieu, V. N.
Powiązania:
https://bibliotekanauki.pl/articles/91782.pdf
Data publikacji:
2016
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
Cuckoo search algorithm
optimal placement and sizing
shunt VAR compensator
optimal power flow
FACTS
Opis:
This paper presents an application of Cuckoo search algorithm to determine optimal location and sizing of Static VAR Compensator. Cuckoo search algorithm is a modern heuristic technique basing Cuckoo species’ parasitic strategy. The L´evy flight has been employed to generate random Cuckoo eggs. Moreover, the objective function is a multiobjective problem, which minimizes loss power, voltage deviation and investment cost of Static VAR Compensator while satisfying other operating constraints in power system. Cuckoo search algorithm is evaluated on three case studies and compared with the Teaching-learning-based optimization, Particle Swarm optimization and Improved Harmony search algorithm. The results show that Cuckoo search algorithm is better than other optimization techniques and its performance is also better.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2016, 6, 2; 59-68
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimal Power Flow by Interior Point and Non Interior Point Modern Optimization Algorithms
Optymalizacja rozpływu mocy w systemie elektroenergetycznym z zastosowaniem nowoczesnych algorytmów optymalizacji interior point oraz non interior point
Autorzy:
Połomski, M.
Baron, B.
Powiązania:
https://bibliotekanauki.pl/articles/396850.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
optimal power flow
interior point
non-interior point
optymalizacja rozpływu mocy
non interior point
Opis:
W  artykule zaprezentowano algorytm prymalno-dualnej metody punktu wewnętrznego oraz nowy wariant metody optymalizacji non interior point, w  zastosowaniu do  zadania optymalizacji rozpływu mocy w  systemie elektroenergetycznym. Opisane algorytmy zostały zaimplementowane w  autorskim oprogramowaniu. Przeprowadzone ekspery- menty obliczeniowe, wskazują przydatność oprogramowania i  zaimplementowanych algorytmów w  zakresie wyznaczenia rozwiązania zadania optymalizacji rozpływu mocy w  systemie elektroenergetycznym, w  tym dla modelu systemu o rozmiarach porównywalnych z rozmiarami Krajowego Systemu Elektroenergetycznego (KSE).
The idea of optimal power flow (OPF) is to determine the optimal settings for control variables while respecting various constraints, and in general it is related to power system operational and planning optimization problems. A vast number of optimization methods have been applied to solve the OPF problem, but their performance is highly dependent on the size of a power system being optimized. The development of the OPF recently has tracked significant progress both in numerical optimization techniques and computer techniques application. In recent years, application of interior point methods to solve OPF problem has been paid great attention. This is due to the fact that IP methods are among the fastest algorithms, well suited to solve large-scale nonlinear optimization problems. This paper presents the primal-dual interior point method based optimal power flow algorithm and new variant of the non interior point method algorithm with application to optimal power flow problem. Described algorithms were implemented in custom software. The experiments show the usefulness of computational software and implemented algorithms for solving the optimal power flow problem, including the system model sizes comparable to the size of the National Power System.
Źródło:
Acta Energetica; 2013, 1; 132-146
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interior Point Method Evaluation for Reactive Power Flow Optimization in the Power System
Ocena możliwości wykorzystania metody punktu wewnętrznego do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym
Autorzy:
Lubośny, Z.
Dobrzyński, K.
Klucznik, J.
Powiązania:
https://bibliotekanauki.pl/articles/397594.pdf
Data publikacji:
2013
Wydawca:
ENERGA
Tematy:
optymalizacja rozpływu mocy biernej
metoda punktu wewnętrznego
reactive power flow optimization
interior point method
Opis:
The paper verifies the performance of an interior point method in reactive power flow optimization in the power system. The study was conducted on a 28 node CIGRE system, using the interior point method optimization procedures implemented in Power Factory software.
W artykule poddano weryfikacji metodę punktu wewnętrznego pod kątem jej wykorzystania do optymalizacji rozpływu mocy biernej w systemie elektroenergetycznym. Rozważania przeprowadzono na 28-węzłowym systemie CIGRE, z wykorzystaniem zaimplementowanej metody punktu wewnętrznego w programie Power Factory firmy DIgSILENT.
Źródło:
Acta Energetica; 2013, 1; 90-101
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of UPFC for enhancement of voltage profile and minimization of losses using Fast Voltage Stability Index (FVSI)
Autorzy:
Kumar, S.
Renuga, P.
Powiązania:
https://bibliotekanauki.pl/articles/140514.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flexible AC transmission system (FACTS)
real and reactive power
Unified Power Flow Controller (UPFC)
Bacterial Foraging (BF) algorithm
Opis:
Transmission line loss minimization in a power system is an important research issue and it can be achieved by means of reactive power compensation. The unscheduled increment of load in a power system has driven the system to experience stressed conditions. This phenomenon has also led to voltage profile depreciation below the acceptable secure limit. The significance and use of Flexible AC Transmission System (FACTS) devices and capacitor placement is in order to alleviate the voltage profile decay problem. The optimal value of compensating devices equires proper optimization technique, able to search the optimal solution with less computational burden. This paper presents a technique to provide simultaneous or individual controls of basic system parameter like transmission voltage, impedance and phase angle, thereby controlling the transmitted power using Unified Power Flow Controller (UPFC) based on Bacterial Foraging (BF) algorithm. Voltage stability level of the system is defined on the Fast Voltage Stability Index (FVSI) of the lines. The IEEE 14-bus system is used as the test system to demonstrate the applicability and efficiency of the proposed system. The test result showed that the ocation of UPFC improves the voltage profile and also minimize the real power loss.
Źródło:
Archives of Electrical Engineering; 2012, 61, 2; 239-250
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sterowanie przepływami mocy w systemie elektroenergetycznym z wykorzystaniem transformatorów z regulacją wzdłużno-poprzeczną
The control of power flows in power system using phase-angle voltage control transformers
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/266590.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
rozpływ mocy
zespół transformatorowy
regulacja wzdłużono-poprzeczna
power flow
transformer unit
phase-angle voltage control
Opis:
Transformatory z regulacją wzdłużno-poprzeczną pozwalają na kształtowanie zarówno poziomu, jak i kąta napięcia. Daje to możliwość regulacji parametrów stanu układu przesyłowego, a w efekcie wpływa na zmianę rozpływu mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
The functioning of the power transmission system is the result of using, among others, devices for the transmission and transformation electricity. Proper operation and control of these devices allows to maintain the correct parameters and continuity of electricity supply to final customers. In the group of devices of electricity transformation it can be distinguished from control transformers that have the ability to shape both the magnitude and the angle of voltage. In this way, it can be adjusted state parameters of power system allow the selection of the size of active and reactive power transmission. This property lets they provide a potential opportunity to influence the power load flow (including active power) in electric power networks. The paper is presented a problem of phase-angle voltage control in power system and model of such a transformer unit. The presented transformer unit model are used for power network calculation, especially to power flows control. It was prepare some power flows cases in high voltage networks. There is presented results of power flow system study with using the voltage angle control of such transformer units.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 73-80
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studium wykorzystania przekształtnika macierzowego do budowy przesuwnika fazowego
The study of the application of matrix converter into phase shifting device
Autorzy:
Sieńko, T.
Szczepanik, J.
Powiązania:
https://bibliotekanauki.pl/articles/266964.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przekształtnik macierzowy
przesuwnik fazowy
FACTS
kontrola rozpływu mocy
matrix converter
phase shifter
power flow control
Opis:
W pracy wykonano analizę zastosowania wielofazowego Przekształtnika Macierzowego (PM) do budowy Przesuwnika Fazowego (PS). Analizę przeprowadzono przy pomocy technik symulacyjnych oraz pomiarów wykonanych na sześciofazowym modelu przekształtnika zbudowanym w laboratorium. Zaprezentowano trzy podstawowe schematy kontroli oraz ich związek z własnościami PM. Poza zdolnością przesuwnika fazowego do zmiany transferu mocy czynnej, interesujący jest wpływ urządzenia na transmisję mocy biernej co pokazano w artykule. Nowo pokazane właściwości PM pozwalają na budowę PS o większych możliwościach kontroli Systemu ElektroEnergetycznego (SEE) niż obecnie dostępne urządzenia. Możliwości różnych wariantów sterowania PM, oraz duża prędkość reakcji bazującego na nim PS będą niewątpliwie przydatne w kontroli stanów dynamicznych pracy SEE (stanach po zaburzeniowych) np. do szybkiej likwidacji kołysań generatorów czy regulacji rozpływu mocy.
Nowadays, in modern power systems there is a tendency to build more and more dispersed energy sources, to increase their transmission abilities and to increase their size. Parallel to these actions, the requirements regarding the quality of the delivered energy and system reliability are also increased. These changes required the new solutions to system control in both static and dynamic states of work to be implemented. The paper includes the analysis of the application of the multiphase Matrix Converter (MC) to the development of the phase shifting device. The analysis was performed not only on the basis of the simulation, but also on the basis of the waveforms obtained from the real life model constructed in the laboratory. The relationships between the device control algorithms and the properties of the built on their basis phase shifting device were thoroughly investigated. Some of the described properties of the MC are not only connected to its ability to influence active power flow in the power line, but also to its impact on reactive power transmission. For three developed control procedures, the reactive power flow control was investigated for MC working as a voltage source inverter on inductive load. The capabilities of alternative control procedures and short device reaction times can be useful not only for power flow control, but also during system dynamic states for example to fast dumping of the system oscillations. The research is the continuation of the previously published work, and its next step will include the solution to the MC commutation problems and the implementation of the MC based shifting device to the already build model of the multi-node power system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 93-96
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zarządzanie ryzykiem technicznym w procesie planowania rozwoju sieci dystrybucyjnej
Technical risk management of grid development planning
Autorzy:
Czarnecki, B.
Zieliński, P.
Powiązania:
https://bibliotekanauki.pl/articles/268356.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
planowanie rozwoju systemu
analiza stochastyczna
zarządzanie ryzykiem
grid development planning
risk management
probabilistic power flow
Opis:
Zarządzanie ryzykiem wymaga kwantyfikacji zagrożeń w kategoriach prawdopodobieństwa wystąpienia przyczyn zagrożenia, oraz konsekwencji wynikających z zaistnienia krytycznych zdarzeń. Największe zagrożenie stwarzają zdarzenia o dużym prawdopodobieństwie i co najmniej znacznych skutkach, oraz zdarzenia o dużych konsekwencjach i co najmniej znacznym prawdopodobieństwie. W tym kontekście zarządzanie ryzykiem polega na podejmowaniu działań mających na celu obniżenie prawdopodobieństwa wystąpienia przyczyn powodujących zagrożenia i/lub minimalizację skutków wystąpienia zagrożeń. W przypadku zarządzania ryzykiem związanym z planowaniem rozwoju sieci WN, podstawowym zagrożeniem są przeciążenia sieci. Planowanie rozwoju sieci ma za zadanie między innymi zagwarantowanie niezawodności i minimalizację kosztów dostaw energii. Realizacja tych dwóch sprzecznych funkcji celu wymaga optymalizacji alokacji środków inwestycyjnych.
Risk management needs to be quantified in terms of probability of events causes threads, and the consequences of the occurrence of critical events. The greatest threats are caused by events of a high probability and at least significant consequences, and events with very serious consequences, and at least a significant probability. In this context, risk management is to take actions to reduce probability of the events causing the threat or minimize the effects of hazards. Managing the risks associated with high-voltage grid development planning, the primary threat is network congestion. Network development planning aims, i.a., ensuring reliability and minimizing the cost of energy supply. The implementation of these trade off pose to optimize the allocation of investment expenditures. Maintaining the reliability of the network in the future, with the increase in demand and power of connected renewable energy sources, can be realized alternatively based on: °minimize the effects of threats through planning the network reinforcement. ° minimize probability of critical events while planning and operating the future system by identifying and avoiding risks.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 27-30
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative study of GA & DE algorithm for the economic operation of a power system using FACTS devices
Autorzy:
Bhattacharyya, B.
Gupta, V. K.
Kumar, S.
Powiązania:
https://bibliotekanauki.pl/articles/141459.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FACTS devices
line power flow
FACTS devices & its optimal locations
genetic algorithm
differential evolution technique
Opis:
The problem of improving the voltage profile and reducing power loss in electrical networks must be solved in an optimal manner. This paper deals with comparative study of Genetic Algorithm (GA) and Differential Evolution (DE) based algorithm for the optimal allocation of multiple FACTS (Flexible AC Transmission System) devices in an interconnected power system for the economic operation as well as to enhance loadability of lines. Proper placement of FACTS devices like Static VAr Compensator (SVC), Thyristor Controlled Switched Capacitor (TCSC) and controlling reactive generations of the generators and transformer tap settings simultaneously improves the system performance greatly using the proposed approach. These GA & DE based methods are applied on standard IEEE 30 bus system. The system is reactively loaded starting from base to 200% of base load. FACTS devices are installed in the different locations of the power system and system performance is observed with and without FACTS devices. First, the locations, where the FACTS devices to be placed is determined by calculating active and reactive power flows in the lines. GA and DE based algorithm is then applied to find the amount of magnitudes of the FACTS devices. Finally the comparison between these two techniques for the placement of FACTS devices are presented.
Źródło:
Archives of Electrical Engineering; 2013, 62, 4; 541-552
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mitigation of the wind generation integration related power quality issues by energy storage
Autorzy:
Kook, K. S.
Liu, Y.
Atcitty, S.
Powiązania:
https://bibliotekanauki.pl/articles/262823.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
wind turbine generator (WTG)
wind farm
Power Quality Energy storage system (ESS)
power flow fluctuation
PSS/E
power system stability
Opis:
The wind power which has been expected to be a promising alternative energy source can bring new challenges when it is connected to the power grid due to the fluctuation nature of the wind and the comparatively new types of its generators. This paper illustrates a possible solution to mitigate these integration issues of the wind power by application of the energy storage to the wind farm in power systems focusing on its short-duration perspective. The simulation model for the Energy Storage System (ESS) connected to the wind farm is implemented using the Power System Simulator for Engineering(PSS/E) which is one of the most widely used program for the power system analysis in US. Employing a sample power system, the control effect of the ESS for mitigating the wind generation related power quality issues by suppressing the power flow fluctuation of the wind farm, and improving power system stability is validated. The counteracting effect of the ESS in the wind farm to the disturbance on the grid is also shown.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 77-82
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of commutation conditions on steady states in matrix converter
Autorzy:
Borkowski, D.
Sobczyk, T. J.
Powiązania:
https://bibliotekanauki.pl/articles/141341.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik macierzowy
regulacja przepływu mocy
metoda bilansu harmonicznych
matrix converter
power flow control
harmonic balance method
Opis:
The paper investigates a significant influence of transients on steady states in a matrix converter with the one-periodic control strategy. Proposed controller can be used as an interconnection device within a power system for a power flow control. However, the presence of inductances in external systems has the significant influence on steady state of a matrix converter operation. The special current injection method has been developed to ensure a proper operation of a matrix converter. Presented analysis of steady states is carried out in a frequency domain using the harmonic balance method. Obtained numerical results, which are confirmed by a time domain analysis, prove the effectiveness of the proposed method.
Źródło:
Archives of Electrical Engineering; 2011, 60, 1; 77-83
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A method for enhancing power system’s steady-state voltage stability level by considering active power optimal dispatch with linear grid models
Metoda poprawy stabilności napięciowej SEE, zakładając optymalną dyspozycję mocy czynnej przy liniowym modelu sieci
Autorzy:
Drabecki, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/266321.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
Voltage Stability
Optimal Power Flow
Optimisation
Market Management Systems
Stabilność Napięciowa
Optymalizacja
Systemy Zarządzania Rynkiem Energii
Opis:
In this study I propose an optimisation approach towards enhancing power systems’ voltage stability level which links reactive power redispatch of existing generating units with adding new reactive power compensators to the system. For voltage stability assessment, two methods were used: Continuation Power Flow and Modal Analysis. The main target was to link voltage stability enhancement module with active power dispatch via optimisation problems with linear grid models, such as DC-OPF. Thanks to such an approach, the method can be implemented by operators that solve similar problems in their Market Management Systems (MMS). For testing purposes the method was implemented using MATLAB with MATPOWER. LP/QP optimisation problems were coded in CVX 2.0 and solved with MOSEK 8.0. The approach was tested on 30-bus IEEE 30 and 200-bus Illinois 200 test systems.
Praca przedstawia algorytm zwiększający poziom stabilności napięciowej SEE wykorzystując optymalną dyspozycję mocy przez rozwiązywanie zadań typu DC-OPF. Dla dobranych przez nie punktów pracy mocy czynnej przystępuje do zarządzania dyspozycją mocy biernej tak, aby zwiększyć poziom stabilności napięciowej. Początkowo, celem poprawy poziomu stabilności napięciowej, próbuje redyspozycji generacji mocy biernej już istniejących jednostek wytwórczych. Gdy nie przynosi ona zadowalającego efektu, iteracyjnie budowane są kompensatory mocy biernej. Dyspozycja mocy czynnej przez zadania o liniowym modelu sieciowym pozwala na implementację prezentowanej metody przez operatora, który z nich korzysta do zarządzania pracą SEE oaz planowania inwestycji. W pracy do analizy poziomu stabilności napięciowej wykorzystywany był algorytm Continuation Power Flow oraz Analiza Modalna. Na potrzeby testów wykorzystano środowisko MATLAB z pakietem MATPOWER i interfejsem modelowania CVX 2.0 oraz solwer LP/QP MOSEK 8.0. Testy przeprowadzono dla 30-węzłowej sieci IEEE 30 i 200-węzłowej syntetycznej Illinois 200.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 55-58
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of LHS sampling to calculate probabilistic power flow
Wykorzystanie losowań metodą LHS do obliczeń probabilistycznego rozpływu mocy
Autorzy:
Przygrodzki, M.
Lubicki, W.
Powiązania:
https://bibliotekanauki.pl/articles/397062.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
probabilistic power flow
simulation methods
transmission system reliability
probabilistyczny rozpływ mocy
niezawodność układu przesyłowego
metody symulacyjne
Opis:
Power flow is the task of determining node voltages and branch loads in a given state of the power system. In the case of probabilistic flow, the task’s input data and calculation results alike are in the form of probability distributions. These distributions can be specified for the power demand, power generation availability and levels in nodes, and grid configuration. Elements that make up the grid configuration may be assigned a binary distribution, the result of which determines the element’s status (on or off). This distribution characteristic parameter is the failure rate of the element. This paper presents the results of a comparison of Monte Carlo and LHS sampling. The sampling concerned grid infrastructure availability. Calculations were made for two grid systems with different sizes corresponding to the test model (ca. 50 branches) and the national transmission grid model (over 400 branches). Based on the results, conclusions were drawn as to the possibility of using LHS simulation in the probabilistic power flow calculation.
Rozpływ mocy jest zadaniem wyznaczenia wartości napięć węzłowych oraz obciążeń gałęziowych w danym stanie systemu elektroenergetycznego. W przypadku probabilistycznego rozpływu zarówno dane wejściowe zadania, jak i wyniki obliczeń mają postać rozkładów prawdopodobieństwa. Rozkłady te można określić dla zapotrzebowania na moc, dostępności i poziomu generacji mocy w węzłach oraz konfiguracji układu sieciowego. Elementom tworzącym konfigurację układu sieciowego można przypisać rozkład dwustanowy, w wyniku którego określa się stan elementu (element pracuje lub jest wyłączony). Parametrem charakterystycznym tego rozkładu jest współczynnik awaryjności danego elementu. W artykule przedstawiono wyniki porównania losowań przeprowadzonych metodą Monte Carlo oraz metodą LHS. Losowania te dotyczyły dostępności infrastruktury sieciowej. Obliczenia przeprowadzono dla dwóch układów sieciowych o różnej liczebności odpowiadającej modelowi testowemu (około 50 gałęzi) oraz modelowi krajowej sieci przesyłowej (ponad 400 gałęzi). Na podstawie uzyskanych wyników sformułowano wnioski co do możliwości wykorzystania symulacji metodą LHS w obliczeniach probabilistycznego rozpływu mocy.
Źródło:
Acta Energetica; 2017, 2; 189-196
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda określania zdolności przyłączeniowych węzłów sieci zamkniętej NN z wykorzystaniem dwupoziomowej optymalizacji typu „black-box” – studium przypadku
Method of connection capacity determination in HV closed network by the use of bi-level “black-box” optimization – a case study
Autorzy:
Wędzik, A.
Powiązania:
https://bibliotekanauki.pl/articles/266633.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
Optimization
Black-box
connection capacity
Optimal Power Flow
optymalizacja
„Black-box”
zdolności przyłączeniowe
optymalizacja rozpływu mocy
Opis:
W chwili obecnej, do wyznaczania zdolności przyłączeniowych węzłów sieci przesyłowej i dystrybucyjnych, wykorzystuje się zazwyczaj metodę węzłów koherentnych. Metoda ta posiada jednak pewne ograniczenia, które nie pozwalają w sposób jednoznaczny wyznaczyć poszukiwanych wartości mocy, określających zdolności przyłączeniowe węzłów analizowanej sieci. W artykule zaproponowana została nowa metoda rozszerzenia możliwości określania zdolności przyłączeniowych węzłów dowolnej sieci zamkniętej NN, z wykorzystaniem dwupoziomowej optymalizacji typu „Black-box”. Obliczenia i analizy wykonane zostały dla pełnego, nieliniowego modelu polskiego KSE. Otrzymane wyniki, pokazują możliwości wykorzystania tej metody dla dowolnej konfiguracji węzłów poddawanych analizie, bez konieczności przeprowadzania podziałów na grupy koherentne. Zaproponowana metoda wykazała możliwości uwzględniania w obliczeniach wszelkich ograniczeń istotnych z punktu widzenia poprawnej pracy systemu, takich jak: dopuszczalne poziomy napięć, dopuszczalne obciążenia linii, maksymalne moce zwarciowe w węzłach sieci czy stany awaryjne (n-1) pracy systemu.
In the presented article the bi-level "Black-box" optimization method was proposed for improvement of connection capacity determination in nodes of any HV closed network. The calculations and analyzes were made for the full non-linear model of Polish Power System. The obtained results show the possibility of using this method for determination of a connection capacity for any configuration of nodes, without determination of coherent groups. The proposed method takes into account all limitations relevant to the safe operation of the system, such as bus voltage levels, line load and maximum bus short-circuit currents, both in power system normal operation and in contingency states (n-1).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 167-170
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of kinematics and dynamics of the vehicle drive system with a parallel power flow transmission
Analiza kinematyki i dynamiki układu napędowego z przekładnią z równoległym przepływem mocy
Autorzy:
Pawelski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1363590.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
automotive transmission
urban traffic
parallel power flow transmission
przekładnia
ruch miejski
przekładnia z równoległym przepływem mocy
Opis:
A method that makes it possible to analyse a vehicle drive system with a compound parallel power flow transmission even as early as at the project design stage has been presented. The essence of this method lies in determining the values of two characteristic transmission speed ratios i1 and i2 of the compound system at which the power transmitted by the continuously variable transmission (CVT) changes its sign, referred to as “zero-power” speed ratios. These speed ratios determine the power curve in the whole speed ratio regulation range from i1 to i2 and thus, the speed and torque curves at the CVT input and output shafts. Thanks to this, the structure of the compound transmission can be so selected that the loads of individual CVT subassemblies would not exceed the acceptable levels and they would be kept within the predefined limits. As an example, the drive trains of four gearboxes with parallel power flow, possible to be found at present in Poland, were analysed with the use of this method, i.e. the Voith DIWA and Allison EV Drive models and a prototype built at the Lodz University of Technology (TUL), designed for city buses, and the Toyota Prius or Lexus passenger car gearboxes. Moreover, a CVT friction gear and a conventional gearbox were analysed for their properties to be compared with those of the parallel power flow systems.
W artykule przedstawiono metodę pozwalającą przeprowadzić analizę układu napędowego ze złożoną przekładnią z równoległym przepływem mocy, już na etapie projektu. Istotą tej metody jest wyznaczenie wartości dwóch charakterystycznych przełożeń i1 oraz i2 układu złożonego, przy których moc przenoszona przez przekładnię bezstopniową zmienia znak, tzw. „moc zerowa”. Przełożenia te określają przebieg mocy w całym zakresie regulacji przełożenia od i1 do i2, a tym samym również przebieg prędkości i momentów obrotowych na wejściu i wyjściu z przekładni bezstopniowej. Możliwy jest więc dobór struktury przekładni złożonej tak, aby obciążenia podzespołów przekładni bezstopniowej nie przekraczały wartości dopuszczalnych i były utrzymane w założonych granicach. Przykładowo, posługując się tą metodą przeprowadzono analizę układów napędowych czterech skrzyń z równoległym przepływem mocy, spotykanych obecnie w Polsce i tak: w autobusach miejskich – skrzynia DIWA firmy Voith, EV Drive firmy Allison, prototyp PŁ oraz w samochodzie osobowym – Toyota-Prius czy Lexus. Ponadto własności układów równoległych uzupełniono analizą rozwiązań z przekładnią cierną CVT jako bezstopniową oraz z konwencjonalną skrzynią biegów.
Źródło:
Archiwum Motoryzacji; 2016, 71, 1; 87-115
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart control of energy storage system in residential photovoltaic systems for economic and technical efficiency
Autorzy:
Kaczorowska, Dominika
Rezmer, Jacek
Janik, Przemysław
Sikorski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2202548.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
economic efficiency
energy storage system ESS
microgrid management
optimal power flow
OPF
particle swarm optimisation PSO
Opis:
In recent years, due to the increasing number of renewable energy sources, which are characterised by the stochastic nature of the generated power, interest in energy storage has increased. Commercial installations use simple deterministic methods with low economic efficiency. Hence, there is a need for intelligent algorithms that combine technical and economic aspects. Methods based on computational intelligence (CI) could be a solution. The paper presents an algorithm for optimising power flow in microgrids by using computational intelligence methods. This approach ensures technical and economic efficiency by combining multiple aspects in a single objective function with minimal numerical complexity. It is scalable to any industrial or residential microgrid system. The method uses load and generation forecasts at any time horizon and resolution and the actual specifications of the energy storage systems, ensuring that technological constraints are maintained. The paper presents selected calculation results for a typical residential microgrid supplied with a photovoltaic system. The results of the proposed algorithm are compared with the outcomes provided by a deterministic management system. The computational intelligence method allows the objective function to be adjusted to find the optimal balance of economic and technical effects. Initially, the authors tested the invented algorithm for technical effects, minimising the power exchanged with the distribution system. The application of the algorithm resulted in financial losses, €12.78 for the deterministic algorithm and €8.68 for the algorithm using computational intelligence. Thus, in the next step, a control favouring economic goals was checked using the CI algorithm. The case where charging the storage system from the grid was disabled resulted in a financial benefit of €10.02, whereas when the storage system was allowed to charge from the grid, €437.69. Despite the financial benefits, the application of the algorithm resulted in up to 1560 discharge cycles. Thus, a new unconventional case was considered in which technical and economic objectives were combined, leading to an optimum benefit of €255.17 with 560 discharge cycles per year. Further research of the algorithm will focus on the development of a fitness function coupled to the power system model.
Źródło:
Archives of Electrical Engineering; 2023, 72, 1; 81--102
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical Modelling of Sound Radiation from a T Junction of City Roads in Windy Conditions
Autorzy:
Piddubniak, O.
Piddubniak, N.
Powiązania:
https://bibliotekanauki.pl/articles/176734.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
T junction of city roads
traffic noise propagation
stationary phase method
acoustic pressure
power flow density
Opis:
The sound radiation from vehicles travelling on the city roads with T junction was considered. The wind effect on acoustic field was taken into account. The solution of this problem was found with the help of the integral Fourier transforms and stationary phase method as the superposition of solutions for the cases of vehicles moving along the straight roads and roads with right-angle bend. As an example, the numerical analysis of traffic noise characteristics was carried out for the T junction city road on one of streets in the town of Łódź (Poland).
Źródło:
Archives of Acoustics; 2016, 41, 3; 543-558
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic adjustment of phase shifting transformers – the ability to control the active power flow in international exchange lines
Automatyczne sterowanie przesuwnikami fazowymi – możliwości regulacji przepływu mocy czynnej w liniach wymiany międzynarodowej
Autorzy:
Opala, K.
Ogryczak, T.
Powiązania:
https://bibliotekanauki.pl/articles/397314.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
phase shifting transformers
control system
active power flow control
przesuwnik fazowy
system sterowania
regulacja przepływu mocy czynnej
Opis:
The authors presented the characteristics of Mikułowa substation in terms of its location and grid connections, brief functional description of its automatic controls, and the results of tests of the automatic control of four phase shifting transformers installed in Mikułowa – Hagenwerder international exchange lines. The tests were carried out as part of the phase shifting transformers’ commissioning at Mikułowa substation in 2016. These results allow one to verify the actual range of control of active power flow between the power system of Poland and Germany, and the control’s effect on the power flow in the NPS. This is the first such installation on a cross-border interconnection in Poland. So far the active power flow in the National Power System (NPS) has never been altered with the use of phase shifting transformers.
Autorzy przedstawili charakterystykę stacji elektroenergetycznej Mikułowa ze względu na jej lokalizację i powiązania sieciowe, skrócony opis funkcjonalny zastosowanej automatyki oraz wyniki badań działania układu automatycznej regulacji czterech przesuwników fazowych zainstalowanych w liniach wymiany międzynarodowej Mikułowa – Hagenwerder. Badania wykonano w ramach prac uruchomieniowych przesuwników fazowych prowadzonych w SE Mikułowa w 2016 roku. Wyniki te pozwalają zweryfikować rzeczywisty zakres regulacji przepływu mocy czynnej pomiędzy systemem elektroenergetycznym Polski i Niemiec oraz wpływ regulacji na rozpływ mocy czynnej w KSE. Jest to pierwsza tego typu instalacja na połączeniu transgranicznym w Polsce. Zmiana przepływu mocy czynnej z wykorzystaniem przesuwników fazowych nie była dotychczas stosowana w Krajowym Systemie Elektroenergetycznym (KSE).
Źródło:
Acta Energetica; 2017, 2; 149-157
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie możliwości regulacji przepływu mocy czynnej w liniach wymiany międzynarodowej
Exploring the possibility of controlling the active power flow in the cross-border tranmission lines
Autorzy:
Ogryczak, T.
Opala, K.
Powiązania:
https://bibliotekanauki.pl/articles/266635.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej
Phase Shifting Transformer
active power flow control
cross-border transmission lines
Opis:
W referacie przedstawiono charakterystykę SE Mikułowa, skrócony opis funkcjonalny zastosowanej automatyki oraz wyniki badań działania układu automatycznej regulacji czterech przesuwników fazowych zainstalowanych w liniach wymiany międzynarodowej Mikułowa – Hagenwerder. Badania wykonano w ramach prac uruchomieniowych przesuwników fazowych prowadzonych w SE Mikułowa w 2016 roku. Wyniki te pozwalają zweryfikować rzeczywisty zakres regulacji przepływu mocy czynnej pomiędzy systemem elektroenergetycznym Polski i Niemiec oraz wpływ regulacji na rozpływ mocy czynnej w KSE. Jest to pierwsza tego typu instalacja na połączeniu transgranicznym w Polsce. Zmiana przepływu mocy czynnej z wykorzystaniem przesuwników fazowych nie była dotychczas stosowana w KSE.
The paper presents the characteristics of SE Mikułowa, a brief functional description of applied automation and research results of operation of automation for the four phase shifters installed in the cross-border transmission lines Mikułowa Hagenwerder. Research carried out in the framework of the phase shifters transformers startup conducted in SE Mikułowa in 2016. These results verify the actual range of controlling the active power flow between Polish and German power system and verify control influence on active power flow in Polish national power system. This is the first installation of such type on a cross-border connection in Poland. Changing the active power flow using the phase shifter transformers has not been used in the Polish national power system.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 87-90
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie wybranych metod symulacyjnych w obliczeniach probabilistycznego rozpływu mocy
Usage of selected simulation method for probabilistic power flow calculations
Autorzy:
Przygrodzki, M.
Lubicki, W.
Powiązania:
https://bibliotekanauki.pl/articles/268098.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
probabilistyczny rozpływ mocy
metody symulacyjne
niezawodność układu przesyłowego
probabilistic power flow
simulation methods
reliability of transmission system
Opis:
Rozpływ mocy jest zadaniem wyznaczenia wartości napięć węzłowych oraz obciążeń gałęziowych w danym stanie systemu elektroenergetycznego. W przypadku probabilistycznego rozpływu zarówno dane wejściowe zadania, jak i wyniki obliczeń mają postać rozkładów prawdopodobieństwa. Rozkłady te można określić dla zapotrzebowania na moc, dostępności i poziomu generacji mocy w węzłach oraz struktury układu sieciowego. W artykule przedstawiono wyniki porównania losowań przeprowadzonych metodą Monte Carlo oraz metodą LHS. Losowania te dotyczyły dostępności infrastruktury sieciowej. Obliczenia przeprowadzono w układzie sieciowym odwzorowującym krajową sieć zamkniętą 400 kV/220 kV/110 kV. Na podstawie przedstawionych wyników symulacji odniesiono się do możliwości wykorzystania metody LHS w prowadzeniu analiz probabilistycznego rozpływu mocy.
Probabilistic power flow is such kind of power flow problem, for which the input data and calculation results have the form of probability distributions. Analogous to the deterministic power flow inputs are defined in the network nodes: the power and electricity demand, availability and level of power generation, defined as probability distributions. In addition, an input data structure is also the network system. The result of the calculation of power flow are probability distributions of voltage in grid nodes and branch power flows. The structure of the network, as part of the network model, understood as the availability of its individual components is a random variable. Variable distribution of binary: the element is on or off. Parameter of this distribution is the failure rate of the item, possibly increased by the rate of planned outage. Generally, the method of determining probabilistic power flow can be divided into simulation, analysis and approximation. Approximation and analytical methods are often combined into one group defined as an analytical method. To determine the value of the input data for the n-th simulation can be used different simulation methods, including Monte Carlo and Latin Hypercube Sampling (LHS). The article presents the results of the comparison draws conducted using Monte Carlo method and LHS. Drawings are concerned the availability of network infrastructure (lines). The calculations were carried out for the national 400 kV, 220 kV and 110 kV network. Simulation result shows possibility of Monte Carlo and LHS method usage for probabilistic power flow calculation.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 53; 61-64
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy przesuwnika fazowego w sieci elektroenergetycznej przy połączeniu transformatora szeregowego w gwiazdę
A computer simulation of the phase shifter effects in the power system with wye connection of the series transformer
Autorzy:
Sarnicki, M.
Tarakan, B.
Zajczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/268014.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przesuwnik fazowy
regulacja przepływu mocy czynnej i biernej
regulacja kąta mocy
Phase Shifter
active and reactive power flow control
power angle
Opis:
Poniższy artykuł prezentuje sposób regulacji mocy czynnej i biernej za pomocą przesuwnika fazowego, którego uzwojenie transformatora dodawczego (szeregowego) jest połączone w gwiazdę. W artykule pokazano regulację mocy czynnej i biernej na przykładzie wybranego systemu elektroenergetycznego. Omawiany przesuwnik fazowy reguluje jednocześnie przepływem mocy czynnej i biernej w danym systemie elektroenergetycznym.
The following article describes the adjustment of the active and reactive power using the phase shifter. The winding of the booster transformer (series) is wye connected. The article shows the regulation of the active and reactive power for selected power system that is 10 bus system with phase shifter. The phase shifter also regulates flow of the active and reactive power simultaneously in the power system. The most common situation is when the both power regulation are independent and it is a better way to have control of both of them. The simultaneous regulation of the active and reactive power is possible by adding transformed voltage from different phases.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 167-169
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of smart transformer on different radialdistribution systems
Autorzy:
Mahmoud, Ibrahem Mohamed A.
Abdelsalam, Tarek Saad
Swief, Rania
Powiązania:
https://bibliotekanauki.pl/articles/1841278.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
smart transformer
smart grid
direct approach
power flow
power loss reduction
inteligentny transformator
inteligentna sieć
bezpośrednie podejście
przepływ mocy
redukcja strat mocy
Opis:
The work is intended to extend the application of a smart transformer on a radialdistribution system. In this paper, an updated algorithm on the backward/forward powerflow is introduced. The so-called direct approach of power flow is employed and analyzed.In addition, the paper focused on integrating a smart transformer to the network and solvingthe updating network also using the direct approach load flow. The solution of the smarttransformer using the direct approach power flow method is quite straightforward. Thismodel is applied to radial distribution systems which are the IEEE 33- and IEEE 69-bussystems as a case study. Also, the paper optimizes the best allocation of the smart transformerto reduce the power losses of the grid.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 271-283
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Circular flow development processes in transmission power networks
Procesy kształtowania się przepływów cyrkulacyjnych w sieciach przesyłowych systemu elektroenergetycznego
Autorzy:
Ziemianek, S.
Powiązania:
https://bibliotekanauki.pl/articles/397611.pdf
Data publikacji:
2012
Wydawca:
ENERGA
Tematy:
przepływy kołowe
przesuwniki fazowe
estymacja stanu
sieć przesyłowa
system elektroenergetyczny
cicrular flows
phase-shifting transformers
power flow tracing
transmission network
power system
Opis:
This paper describes the mechanism of sequential formation of circular fl ows in transmission power networks. These fl ows are detected by a method of automatic identifi - cation of circular fl ows in a meshed transmission network – based on application of the power fl ows tracing theory. Matrices built in power fl ows tracing are reviewed, which in each node tie up the power fl ow with the power generated (or received). This method is very eff ective. It was used to analyze the seemingly abrupt appearance of circular fl ows in a meshed transmission network. Some regularities are observed in the appearances of these fl ows in transmission networks. These are discussed in the example of the known IEEE 118 system.
W artykule opisano mechanizm sekwencyjnego kształtowania się przepływów cyrkulacyjnych w sieciach przesyłowych systemu elektroenergetycznego. Do detekcji tych przepływów wykorzystuje się metodę automatycznej identyfikacji circular flows w oczkowej sieci przesyłowej – metodę opartą na wykorzystaniu teorii śledzenia przepływów mocy. Przegląda się budowane w trakcie śledzenia przepływów mocy macierze wiążące przepływy mocy czynnej przez poszczególne węzły z mocami generowanymi (lub mocami odbieranymi) w poszczególnych węzłach. Metoda jest bardzo efektywna. Zastosowano ją do analiz pozornie skokowego pojawiania się circular flows w oczkowej sieci przesyłowej. Obserwuje się pewne prawidłowości w pojawianiu się tych przepływów w sieciach przesyłowych. Omówiono je na przykładzie znanego systemu IEEE 118.
Źródło:
Acta Energetica; 2012, 2; 93-100
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automatic adjustment of reactive power by FACTS devices under conditions of voltage instability in the electric network
Automatyczna regulacja mocy biernej przez urządzenia FACTS w warunkach niestabilności napięcia w sieci elektrycznej
Autorzy:
Burbelo, Mykhailo J.
Babenko, Oleksii V.
Loboda, Yurii V.
Lebed, Denys Y.
Kolesnytskyj, Oleh
Rakhmetullina, Saula J.
Mussabekov, Murat
Powiązania:
https://bibliotekanauki.pl/articles/28875006.pdf
Data publikacji:
2023
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
reactive power
static synchronous compensator
unified power flow regulator
voltage stability
moc bierna
statyczny kompensator synchroniczny
ujednolicony regulator przepływu mocy
niestabilność napięcia
Opis:
This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in caseof voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The taskof STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generatedby the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However,at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solvethis problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation.In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle ofthe voltage vector changes, which causes a failure in the operation of the regulatorof the parallel compensator UPFC.
W artykule opisano problematykę automatycznej regulacji mocy biernej za pomocą urządzeń elektronicznych FACTS (Flexible AC Transmission Systems): statycznego kompensatora synchronicznego (STATCOM) oraz regulatora przepływu mocy (UPFC). Za pomocą złożonego formularza rejestracyjnego określane są: napięcia w węzłach instalacji urządzenia FACTS i obciążenia, prądy obciążenia, źródeł zasilaniai kompensatorów elektronicznych w przypadku niestabilności napięcia w węźle obciążenia siecielektrycznej. Napięcia i prądy są wyznaczane metodą napięć węzłowych. Zadaniem STATCOM jest częściowa lub pełna kompensacja mocy biernej. Podczas spadku napięcia w węźle obciążenia, moc bierna generowana przez źródło zasilania maleje. STATCOMpowinien częściowo lub w pełni skompensować nierównowagę mocy biernej tak szybko,jak to możliwe. Jednocześnie jednak nie jest możliwe pełne skompensowanie spadku napięcia. W celu rozwiązania tego problemu można zastosować szeregowo-równoległy lub równoległo-szeregowy układ UPFC. W wyniku zastosowania UPFC możliwe jest automatyczne podniesienie poziomu napięcia do akceptowalnych wartości za pomocą kompensatora szeregowego UPFC. Analiza pokazuje, że równoległo-szeregowy UPFC charakteryzuje się stabilnością działania. W przypadku zastosowania szeregowo-równoległego UPFC istnieją ograniczenia w zakresie możliwości regulacji składowej urojonej napięcia kompensatora szeregowego, ponieważ zmienia się kąt wektora napięcia, co powoduje awarię działania regulatora kompensatora równoległego UPFC.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2023, 13, 4; 109--113
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of a High-efficiency and High-frequency 10-kW/800-V Three-phase PWM Converter with Direct Power Factor Control
Autorzy:
Barlik, Roman
Grzejszczak, Piotr
Leszczyński, Bernard
Szymczak, Marek
Powiązania:
https://bibliotekanauki.pl/articles/226672.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
three-phase PWM rectifier
reactive power compensator
silicon carbide MOSFET
bidirectional power flow
direct power control (DPC)
DC voltage regulation
power factor correction (PFC)
LCL filter
Opis:
The paper presents a concept of a control system for a high-frequency three-phase PWM grid-tied converter (3x400 V / 50 Hz) that performs functions of a 10-kW DC power supply with voltage range of 600÷800 V and of a reactive power compensator. Simulation tests (in PLECS) allowed proper selection of semiconductor switches between fast IGBTs and silicon carbide MOSFETs. As the main criterion minimum amount of power losses in semiconductor devices was adopted. Switching frequency of at least 40 kHz was used with the aim of minimizing size of passive filters (chokes, capacitors) both on the AC side and on the DC side. Simulation results have been confirmed in experimental studies of the PWM converter, the power factor of which (inductive and capacitive) could be regulated in range from 0.7 to 1.0 with THDi of line currents below 5% and energy efficiency of approximately 98.5%. The control system was implemented in Texas Instruments TMS320F28377S microcontroller.
Źródło:
International Journal of Electronics and Telecommunications; 2019, 65, 4; 619-624
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stability analysis and efficiency improvement of IPFC using latest PR controller
Autorzy:
Gurijala, Sridhar Babu
Kishore, D. Ravi
Nittala, Ramchandra
Godala, Rohith Reddy
Powiązania:
https://bibliotekanauki.pl/articles/1841160.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control algorithms
FACTS devices
multilevel inverter
interline power flow controller
algorytmy sterowania
FAKTY urządzeń
falownik wielopoziomowy
interline kontroler przepływu mocy
Opis:
The deviation from the ideal waveformcauses disturbances and failure of end-user load equipment. Power traveling a long distance from the generation plant to the end-user leads to deterioration of its quality, and the intensive utilization of power leads to serious issues in the grid resulting in power quality problems. To make the system effective and able to meet modern requirements, flexible AC transmission system (FACTS) devices should be installed into the grid. The interline power flow controller (IPFC) is the latest FACTS device, which compensates for both active and reactive power among multi-line systems. The converters used in the IPFC are crucial as they can be adjusted to regulate the power flow among the lines. This paper proposes a cascaded IPFC with hysteresis and proportional resonant voltage controllers. Some main drawbacks of controllers like steady-state errors and reference tracking of converters can be easily achieved by the PR controller, which makes the system efficient and can be used for a wide range of grid applications. Hysteresis and PR controllers are explained in detail in the following sections. A comparative analysis is carried out among control algorithms to choose the suitable controller which maintains stability in the system.
Źródło:
Archives of Electrical Engineering; 2021, 70, 3; 615-630
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metaheuristic approach to optimal power flow using mixed integer distributed ant colony optimization
Autorzy:
Suresh, Vishnu
Janik, Przemyslaw
Jasinski, Michal
Powiązania:
https://bibliotekanauki.pl/articles/141692.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ant colony optimization
IEEE 30 bus
IEEE 57 bus
metaheuristic algorithm
mixed integer distributed ant colony optimization
optimal power flow
Opis:
This paper presents the application of an improved ant colony optimization algorithm called mixed integer distributed ant colony optimization to optimize the power flow solution in power grids. The results provided indicate an improvement in the reduction of operational costs in comparison with other optimization algorithms used in optimal power flow studies. The application was realized to optimize power flow in the IEEE 30 and the IEEE 57 bus test cases with the objective of operational cost minimization. The optimal power flow problem described is a non-linear, non-convex, complex and heavily constrained problem.
Źródło:
Archives of Electrical Engineering; 2020, 69, 2; 335-348
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Voltage-regulating and Phaseshifting Transformers to Control Power Flows in the Power System
Wykorzystanie transformatorów z regulacją skośną do sterowania przepływami mocy w systemie elektroenergetycznym
Autorzy:
Przygrodzki, M.
Rzepka, P.
Szablicki, M.
Powiązania:
https://bibliotekanauki.pl/articles/397531.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
rozpływ mocy
zespół transformatorowy
regulacja wzdłużno-poprzeczna
active and reactive power flow
regulating transformer
voltage-magnitude-regulating
phase-angle-regulating
Opis:
Transmission system performance results from, among other factors, the use of devices for electricity transmission and transformation. Proper operation and control of these devices allows maintaining proper electricity parameters and the continuous supply to end consumers. In the group of electricity transforming devices transformers can be distinguished by the ability to control both the magnitude and phase angle of voltage. In this way transmission system state parameters are adjusted, which enable selecting the reactive and active power. On the one hand, these are devices of a complex structure, resulting in difficult operating conditions, while on the other hand they provide a potential opportunity to influence the power flow (including active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.active power) in power grids. This article presents the idea of voltage and phase regulation and a transformer regulating unit model. Using the transformer unit’s grid model power analyses were conducted with a focus on evaluating load flow control capabilities. The results of the calculations for the selected transformer unit are presented.
Funkcjonowanie systemu przesyłowego jest wynikiem wykorzystywania pracy m.in. urządzeń służących do przesyłu, jak i transformacji energii elektrycznej. Prawidłowa eksploatacja i sterowanie tymi urządzeniami pozwala na zachowanie właściwych parametrów energii elektrycznej oraz ciągłości zasilania odbiorców końcowych. W grupie urządzeń pozwalających na transformację energii elektrycznej można wyróżnić transformatory z regulacją, które mają możliwość kształtowania zarówno poziomu, jak i kąta napięcia. W ten sposób regulowane są parametry stanu układów przesyłowych pozwalające na dobór przesyłanych wielkości mocy biernej oraz czynnej. Z jednej strony układy te są urządzeniami o skomplikowanej budowie, co wpływa na utrudnione warunki ich eksploatacji, ale jednocześnie z drugiej strony dają one potencjalnie możliwość wpływu na rozpływy mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego, przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
Źródło:
Acta Energetica; 2015, 4; 87-98
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of three approaches to the security constrained unit commitment problem
Porównanie wariantów modeli doboru jednostek i ekonomicznego rozdziału obciążeń
Autorzy:
Drabecki, Mariusz
Toczyłowski, Eugeniusz
Powiązania:
https://bibliotekanauki.pl/articles/266349.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
security constrained unit commitment
economic dispatch
optimal power flow
active and reactive power
dobór jednostek
ekonomiczny rozdział obciążeń
optymalny rozpływ mocy czynnej
optymalny rozpływ mocy biernej
Opis:
A two phase approach to obtain feasibility of the Security Constrained Unit Commitment schedules is analysed. In the first planning phase a computationally tractable variant of the security constrained UC problem is considered with a simplified representation of the network flows. Three computationally tractable variants of the UC problem formulations are investigated: (i) UC_NN model without network flow constraints, (ii) UC_NC model with network constraints reflected by enforcing nodal constraints at the bus level, and (iii) UC_DC model by enforcing network constraints on active power flows. These models are tested and compared with respect to efficiency, computational burden and complexity of the corrective actions performed by TSO in the operational phase to meet security and technical requirements of the system.
W pracy jest analizowane podejście dwufazowe do problemu doboru jednostek i ekonomicznego rozdziału obciążeń w systemie elektroenergetycznym. W pierwszej fazie planistycznej jest rozważany uproszczony wariant problemu doboru jednostek i ekonomicznego rozdziału obciążeń z uproszczonym modelem ograniczeń sieciowych rozpływu mocy. Badane są trzy realistyczne obliczeniowo warianty modelu doboru jednostek i ekonomicznego rozdziału obciążeń: (i) model UC_NN bez ograniczeń sieciowych, (ii) restrykcyjny model UC_NC z ograniczeniami sieciowymi w postaci ograniczeń przepływu na poziomie szyn i łączy, and (iii) model UC_DC uwzględniający model rozpływu mocy czynnej w sieci. Modele te są testowane symulacyjnie i porównywane pod względem obliczeniowym, efektywnościowym oraz złożoności i jakości akcji dostosowawczych Operatora Sieci Przesyłowej w drugiej fazie operacyjnych działań pozwalających na uzyskanie stanów sieci spełniających wymagania bezpieczeństwa i ograniczenia techniczne.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 67-70
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of phase shifting transformers on cross-border power flows in the Central and Eastern Europe region
Autorzy:
Korab, R.
Owczarek, R.
Powiązania:
https://bibliotekanauki.pl/articles/201812.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase shifting transformers
power flow control
cross-border power flows
unscheduled flows
tie-lines
transformator
sterowanie przepływem mocy
przesunięcie fazowe
energia przepływu
przepływ mocy
przepływy nieplanowe
Opis:
Unscheduled power flows are a serious problem for the Central and Eastern Europe (CEE) region. One method of reducing these undesirable flows relies on the use of phase shifting transformers (PSTs). This paper presents how the installation of PSTs on the Polish-German and Czech-German borders affects cross-border power flows in the CEE region, as well as interactions between these devices. The essential parameters proposed for PSTs are based on the effects arising from the application of PSTs on the border between Poland and Germany. The results demonstrate that the use of PSTs in the CEE region can provide effective control of active power flows in tie-lines and significantly reduce unscheduled flows. However, the operation of these devices must be coordinated in order to achieve maximum controllability and to guarantee the secure operation of the interconnected systems.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 1; 127-133
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies