Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power cycle" wg kryterium: Temat


Tytuł:
The cooling rate of the heated vapor compression cycle in case of using refrigerants R134a, R22, and R600a
Autorzy:
Abd-Elhady, Mohamed Salama
Melad, Emmanoueil Bishara
Abd-Elhalim, Mohamed
Seif Alnasr, Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1845463.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
compression
cycle
power saving
refrigerant
refrigerating cycle
cooling rate
Opis:
The most power consuming part in the vapor compression cycle (VCC) is the gas compressor. Heating the refrigerant under constant volume after the compressor increases the condenser pressure, which consequently increases the cooling rate of the VCC. This study examined the influence of heating different refrigerants, i.e. R143a, R22, and R600a on the cooling rate of the VCC. Four experiments have been performed: the first experiment is a normal VCC, i.e. without heating, while in the second, third, and fourth experiments were carried out to raise the temperature of the refrigerant to 50◦C, 100◦C, and 150◦C. It has been found that heating raises the refrigerant pressure in VCC and thereby improves the refrigerant’s mass flow rate resulting in an improvement in the cooling power for the same compressor power. Heating the refrigerant after the mechanical compressor increases the temperature of the condenser as well as the temperature of the evaporator when using refrigerant R134a, which prevents the refrigeration cycle to be used in freezing applications, however using refrigerant R22 or refrigerant R600a promotes the heated VCC to be used in freezing applications. Refrigerant R600a has the lowest operating pressure compared to R134a and R22, which promotes R600a to be used rather than R134a and R22 from a leakage point of view.
Źródło:
Archives of Thermodynamics; 2021, 42, 2; 11-30
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Impact of Energy Source on the Life-Cycle Assessment of Power-to-Liquid Fuels
Autorzy:
Alhyari, Maha
Al-Salaymeh, Ahmed
Irshidat, Mahmoud
Kaltschmitt, Martin
Neuling, Ulf
Powiązania:
https://bibliotekanauki.pl/articles/123121.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
power-to-liquid
life cycle assessment
Opis:
Power-to-liquid (PtL) fuels are a promising technology and alternative to biofuels and conventional fuels. In this work, the environmental impact of PtL was investigated using life cycle assessment (LCA) in order to see how the energy source used in producing the PtL affects the environmental impacts of the fuel. The electrolysis cell used was solid oxide electrolysis cell, and the pathway of CO2 provision was biomass power plant. Four scenarios of energy sources were compared; the first scenario involved the electricity from German grid and heat from chemical industry, the second one was the electricity from Saudi Arabia grid and heat from chemical industry, the third one concerned the electricity from wind turbine and heat from evacuated tube collector, and the fourth scenario was the electricity from photovoltaic and heat from evacuated tube collector. The result of the life cycle assessment showed that the PtL fuels have environmental benefits over the fossil reference only in the third and fourth scenarios where renewable electricity was used.
Źródło:
Journal of Ecological Engineering; 2019, 20, 4; 239-244
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of rest interval between plyometric training sessions on functional performance tests
Autorzy:
Asadi, Abbas
Powiązania:
https://bibliotekanauki.pl/articles/1031770.pdf
Data publikacji:
2015
Wydawca:
PPHU Projack Jacek Wąsik
Tematy:
explosive power
sand
shortening cycle
Opis:
The purpose of this study was to examine the effects of short-term plyometric depth jump training on sand interposed with 48 hours or 72 hours of rest between training sessions on power type muscular adaptations in recreationally physical active men. Fifteen collegiate physical active men, who were familiar with plyometric exercise, participated in this study and were randomly divided into 2 groups: plyometric training with 48 h (PT48, N=7) and 72 h (PT72, N=8) of rest between training sessions. Pre and post training on sand, participants were measured in vertical jump (VJ), standing long jump (SLJ), agility t Test (TT), 20 and 40 m sprints, and one repetition maximum leg press (1RMLP). The plyometric training program on sand was applied during 6 weeks, 2 sessions per week, with 5 sets of 20 repetitions depth jump exercise from 45 cm box height. After completing 6 weeks training period, the PT48 and PT72 groups showed significant improvement in all performance tests (p<0.05), with statistically significant differences between treatments in TT and 40 m sprint time. With regard to significant differences in TT and 40 m sprint for PT72 compared with PT48 and greater improvements for PT72 in all tests, it can be recommend that coaches, strength and conditioning professionals apply 72 h rest between plyometric training sessions when sand surface was used.
Źródło:
Physical Activity Review; 2015, 3; 1-10
2300-5076
Pojawia się w:
Physical Activity Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Possibilities of Electricity Production in Flash Geothermal System in Poland
Ocena możliwości wytwarzania energii elektrycznej przy wykorzystaniu obiegów z separacją pary w polskich warunkach geotermalnych
Autorzy:
Barbacki, A.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/385815.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
energia geotermalna
siłownie geotermalne
obieg z separacją pary
moc właściwa
Polska
geothermal energy
geothermal power plant
flash cycle
specific power
Polska
Opis:
Przedstawiono metodykę oceny dostępnej mocy jednostkowej (odniesionej do strumienia płynu geotermalnego) siłowni geotermalnej wykorzystującej obieg z separacją pary (ang. flash system). Analizy prowadzono, uwzględniając temperaturę kondensacji pary wychodzącej z turbiny przy różnej temperaturze złożowej. Zaproponowano metodykę optymalizacji ciśnienia separacji pary przy założeniu, że ekspansja pary w turbinie zachodzi izentropowo. Uwzględniając te założenia, opracowano analityczną zależność umożliwiającą ocenę optymalnej temperatury (której odpowiada optymalne ciśnienie), dla której powinien być prowadzony proces separacji pary i cieczy. Optymalizację prowadzono z zamiarem osiągnięcia maksymalnej mocy elektrycznej dostępnej dla określonego strumienia płynu geotermalnego. Prezentowane w artykule rozważania zostały zainicjowane badaniami dotyczącymi możliwości wykorzystania systemów ciepła gorących suchych skał HDR (ang. Hot Dry Rock) i geotermalnych systemów wspomaganych EGS (ang. Enhanced Geothermal System) do produkcji energii elektrycznej w polskich warunkach geotermalnych. W centralnej Polsce w utworach triasu dolnego przewiduje się możliwość eksploatacji płynów geotermalnych o temperaturze ponad 130°C. Jednak z uwagi na niewielką osiąganą moc elektryczną, w połączeniu z wysokimi przewidywanymi nakładami inwestycyjnymi (wspominane zasoby energii geotermalnej zalegają na głębokościach większych niż 4000 m), wykorzystanie tych systemów raczej nie będzie opłacalne. Zasoby te mogą zostać jednak efektywnie zagospodarowane do wytwarzania energii elektrycznej w siłowniach binarnych.
An analytical method is described that expresses the specific power of a flash geothermal power plant with flash temperature regarded as a variable. The analysis was carried out for a condensation temperature for fluid exiting a theoretical turbine and for a given geothermal reservoir temperature. The method is a linear approximation of the established method for optimizing separator pressure. This linear approximation makes it possible to obtain an analytical expression for the optimum fl ash temperature (fixing the separation pressure) at which the maximal specific power is obtained. A discussion arose in Poland during extensive research related to the application of binary systems, HDR (Hot Dry Rock), and EGS (Enhanced Geothermal System) technologies for the production of electricity. This concerned the hypothetical possibility of using geothermal flash systems for this purpose. Therefore, the above procedure was applied to Polish geothermal conditions to assess the theoretical possibilities of operating such systems at the reservoir temperatures anticipated in Poland. In the lower Triassic formations in central Poland, there are geothermal resources with temperatures hovering above 130°C. However, low net power values were estimated following the application of the procedure; when combined with the large investment costs involved (the high-temperature resources lie at a depth more than 4000 m), this is not condusive for the efficient application of such systems. On the other hand, the possible application of binary systems to electricity production in that area is realistic and justified.
Źródło:
Geomatics and Environmental Engineering; 2017, 11, 3; 17-29
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hierarchiczne dwuobiegowe gazowo-gazowe i gazowo-parowe elektrownie i elektrociepłownie jądrowe z wysokotemperaturowymi reaktorami i helem oraz wodą i parą jako czynnikami obiegowymi
Autorzy:
Bartnik, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/2080420.pdf
Data publikacji:
2021
Wydawca:
Nowa Energia
Tematy:
paliwo
energetyka
elektrownia gazowa
elektrownia gazowo-parowa
elektrociepłownia jądrowa
reaktor wysokotemperaturowy
fuel
power engineering
gas power plant
combined cycle power plant
nuclear power plant
high temperature reactor
Opis:
Celem artykułu jest przedstawienie innowacyjnych technologii energetycznych elektrowni i elektrociepłowni jądrowych, w których realizowane są dwa obiegi w układzie hierarchicznym.
Źródło:
Nowa Energia; 2021, 5/6; 20--37
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of a combined cycle power plant located in Jordan: A case study
Autorzy:
Bataineh, Khaled
Khaleel, Bara A.
Powiązania:
https://bibliotekanauki.pl/articles/240565.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
energy efficiency
exergy efficiency
exergy destruction
exergy losses
Opis:
Efficiency and electrical power output of combined cycle power plants vary according to the ambient conditions. The amount of these variations greatly affects electricity production, fuel consumption, and plant incomes. Obviously, many world countries have a wide range of climatic conditions, which impact the performance of power plants. In this paper, a thermodynamic analysis of an operating power plant located in Jordan is performed with actual operating data acquired from the power plant control unit. The analysis is performed by using first and second laws of thermodynamics. Energy and exergy efficiencies of each component of the power plant system are calculated and the effect of ambient temperature on the components performance is studied. The effects of gas turbine pressure ratio, gas turbine inlet temperature, load and ambient conditions on the combined cycle efficiency, power outputs and exergy destruction are investigated. Energy and exergy efficiencies of the combined cycle power plant are found as 45.29%, and 42.73% respectively when the ambient temperature is 34°C. Furthermore, it is found that the combustion chamber has the largest exergy destruction rate among the system components. The results showed that 73% of the total exergy destruction occurs in the combustion chamber when the ambient temperature is 34°C. Moreover, the results show that the second major exergy loss is in HRSC. The results show that the energy and exergy efficiency of the combined cycle power plant decreases as the ambient temperature increases. According to the calculation results, improvement and modification suggestions are presented.
Źródło:
Archives of Thermodynamics; 2020, 41, 1; 95-123
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza termoekonomiczna wybranych układów gazowo–parowych
Termoeconomic analysis of Combine Cycle Power Plant
Autorzy:
Bernard, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/101733.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Tematy:
układy gazowo-parowe
turbina gazowa
analiza termodynamiczna
analiza ekonomiczna
EBSILON®Professional
combined cycle power plant
thermodynamic analysis
economic analysis
Opis:
W niniejszej pracy przedstawiono wyniki analizy termodynamicznej oraz ekonomicznej dla wybranych układów gazowo–parowych. Pierwszym rozpatrywanym układem był układ jednociśnieniowy, następnym układ jednociśnieniowy z modernizacją w postaci upust regeneracyjnego i przegrzewu oraz układ dwuciśnieniowy. Wymienione układy przeanalizowano z punktu widzenia zmieniającej się temperatury oraz ciśnienia spalin na wlocie do turbiny. Na potrzeby analizy wybrano cztery lokalizacje mieszczce się w różnych rejonach świata i na ich podstawie wyznaczono zależność sprawności układu od zmiany parametrów otoczenia, przy uwzględnieniu zmiany ciśnienia spalin na dolocie do turbiny gazowej. Kolejnym etapem pracy było wyznaczenie opłacalności finansowej każdego z układów oraz wyznaczenie wskaźników oceny efektywności ekonomicznej. Zostały wyznaczone wskaźniki ekonomiczne takie jak: wartość bieżąca netto, wskaźnik wartości bieżącej netto, wewnętrzna stopa zwrotu oraz zdyskontowany czas zwrotu. Analiza termodynamiczna została przeprowadza przy użyciu komercyjnego oprogramowania EBSILON®Professional (STEAG GmbH).
This work describes thermoeconomical analysis of combined cycle power plant. First analysed configuration is single pressure combined cycle power plant. Next is single pressure combined cycle with modernisation containing heat recovery and additional superheating. Closing structure is dual pressure combined cycle. These power plants were tested due to changing of the temperature and pressure at the inlet to the gas turbine. The next step was selection four locations in different parts of the world. The impact of the changing parameters of the environment on the efficiency of the system was determined. The financial viability of power plant was examined. The indicators of economic efficiency was computed such as NPV, NPVR, IRR and DPB. EBSILON®Professional was used as a program to creation of combined cycle power plants.
Źródło:
Archiwum Instytutu Techniki Cieplnej; 2016, 2; 5-33
2451-277X
Pojawia się w:
Archiwum Instytutu Techniki Cieplnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Risk level analysis in the selected (initial) stage of the project life cycle
Autorzy:
Borecki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1841395.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
project management
risk management
life cycle
power engineering
electrical grid
Opis:
This paper focuses on the analysis of selected risks as part of investments in the power engineering at the initial (tender) stage of the life cycle in the context of the method of project management by the Contractor. The study was carried out on the basis of an analysis of over 500 tenders in the power engineering, from the last 5 years, taking into account future forecast data. The analysis carried out in this article was aimed at achieving specific and unique goals and results aimed at creating a useful product, which is the Contractor’s offer in the power engineering, taking into account the most significant risks. The result of this article is to support the project team in implementing risk management in the project at the tender stage. For this purpose, the risks with their basic parameters were defined, which allowed for the development of a risk matrix taking into account the data obtained in the tender procedures of leading electric power distributors. Based on the proposed risk quantification criteria, a list of remedial actions was prepared for all risk types listed in this article. In addition, the aspects of possible elimination/reduction of the impact of the most significant risks that occur at the analyzed stage of the investment life cycle were developed.
Źródło:
Management and Production Engineering Review; 2020, 11, 4; 104-112
2080-8208
2082-1344
Pojawia się w:
Management and Production Engineering Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of effeciency of waste heat conversion in low-temperature Brayton cycle
Autorzy:
Borsukiewicz, A.
Stawicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/185192.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Brayton cycle
working fluid
low temperature source
low temperature power plant
Cykl Braytona
temperatura
elektrownia o niskiej temperaturze
Opis:
The paper discusses the feasibility, effectiveness and validity of a gas turbine power plant, operated according to the Brayton comparative cycle in order to develop low-potential waste heat (160◦C) and convert it into electricity. Fourteen working fluids, mainly with organic origin have been examined. It can be concluded that low molecular weight working fluids allow to obtain higher power efficiency of Brayton cycle only if conversions without taking into account internal losses are considered. For the cycle that takes into account the compression conversion efficiency in the compressor and expansion in the gas turbine, the highest efficiency was obtained for the perfluoropentane working medium and other substances with relatively high molecular weight values. However, even for the cycle using internal heat recovery, the thermal efficiency of the Brayton cycle did not exceed 7%.
Źródło:
Chemical and Process Engineering; 2018, 39, 1; 103--112
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of heat recuperation in ORC power plant on efficiency of waste heat utilization
Autorzy:
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/240646.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nadkrytyczna siłownia organiczna
odzyskiwanie ciepła
heat recuperation
ORC
subcritical power plant
supercritical organic cycle
Opis:
The present work is devoted to the problem of utilization of the waste heat contained in the exhaust gases having the temperature of 350[degrees]C. Conversion of the waste heat into electricity using a power plant working with organic fluid cycles is considered. Three Organic Rankine Cycle (ORC) power plant solutions are analysed and compared: a solution with the basic, single thermodynamic conversion cycle, one with internal heat recuperation and one with external heat recuperation. It results from the analysis that it is the proper choice of the working fluid evaporation temperature that fundamentally affects the maximum of the ORC plant output power. Application of the internal heat recuperation in the plant basic cycle results in the output power increase of approx. 5%. Addition of the external heat recuperation to the plant basic cycle, in the form of a secondary supercritical ORC power cycle can rise the output power by approx. 2%.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 111-123
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex use of the materials extracted from an open-cast lignite mine
Wielorakie wykorzystanie minerałów wydobywanych z odkrywkowej kopalni lignitu
Autorzy:
Buryan, P.
Bucko, Z.
Mika, P.
Powiązania:
https://bibliotekanauki.pl/articles/219656.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
węgiel
gazyfikacja
czyste technologie węglowe
elektrownia o cyklu mieszanym
coal
gasification
clean coal technology
combined cycle power plant
Opis:
The company Sokolovská uhelná, was the largest producer of city gas in the Czech Republic. After its substitution by natural gas the gasification technology became the basis of the production of electricity in the combine cycle power plant with total output 400 MW. For the possibility of gasification of liquid by- -products forming during the coal gasification a entrained-flow gasifier capable to process also alternative liquid fuels has been in installed. The concentrated waste gas with these sulphur compounds is conducted to the desulphurisation where the highly desired, pure, 96 % H2SO4 is produced. Briquettable brown coal is crushed, milled and dried and then it is passed into briquetting presses where briquettes, used mainly as a fuel in households, are pressed without binder in the punch under the pressure of 175 MPa. Fine brown coal dust (multidust) is commercially used for heat production in pulverized-coal burners. It forms not only during coal drying after separation on electrostatic separators, but it is also acquired by milling of dried coal in a vibratory bar mill. Slag from boilers of classical power plant, cinder form generators and ashes deposited at the dump are dehydrated and they are used as a quality bedding material during construction of communications in the mines of SUAS. Fly ash is used in building industry for partial substitution of cement in concrete. Flue gases after separation of fly ash are desulphurized by wet limestone method, where the main product is gypsum used, among others, in the building industry. Expanded clays from overburdens of coal seams, that are raw material for the production of “Liapor” artificial aggregate, are used heavily. This artificial aggregate is characterized by outstanding thermal and acoustic insulating properties.
Przedsiębiorstwo Sokolovska uhelna jest największym producentem gazu miejskiego w Republice Czeskiej. Po jego zastąpieniu przez gaz ziemny, technologia gazyfikacji stała się podstawą do produkcji elektryczności w elektrowni o cyklu mieszanym o całkowitej mocy wyjściowej 400 MW. W celu umożliwienia gazyfikacji ciekłych produktów ubocznych gazyfikacji węgla, zainstalowano na drodze przepływu generator gazu, umożliwiający przetwarzanie alternatywnych paliw ciekłych. Skoncentrowany gaz odlotowy zawierający związki siarki odprowadzany jest do instalacji odsiarczającej, gdzie produkowany jest cenny produkt H2SO4, o wysokim stopniu czystości (96%). Węgiel brunatny nadający się do produkcji brykietów jest kruszony, mielony i suszony, następnie przechodzi przez proces brykietowania w odpowiednich prasach, gdzie formowane są brykiety, poprzez ich sprasowanie pod ciśnieniem 175 MPa. Brykiety takie wykorzystywane są powszechnie jako paliwo w gospodarstwach domowych. Drobnoziarniste pyły węgla brunatnego (paliwa pyłowe) wykorzystywane są na skalę komercyjną do produkcji ciepła w paleniskach pyłowych. Pyły węglowe powstają nie tylko w trakcie suszenia węgla po procesie oddzielania w separatorach elektrostatycznych, lecz także w procesie mielenia suszonego węgla w młynach wibracyjnych. Żużel z kotłów w konwencjonalnej elektrowni, popioły z generatorów oraz te osadzające się w instalacji podlegają wysuszeniu, następnie wykorzystywane są jako wysokiej jakości materiał na podłoże w różnorodnych instalacjach. Popioły lotne wykorzystywane są przemyśle budowlanym jako częściowe zamienniki cementu. Po oddzieleni popiołu lotnego, gazy wylotowe kierowane są do instalacji odsiarczania z wykorzystaniem technologii wilgotnego wapienia, w wyniku tego procesu powstaje gips, wykorzystywany, miedzy innymi, w przemyśle budowlanym. Glinki z warstw nadkładu nad pokładami węgla wykorzystywane są powszechnie jako surowiec do produkcji sztucznego kruszywa "Liapor", wykazującego wyjątkowe właściwości termiczne i dźwiękoizolacyjne.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1107-1118
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspektywy rozwoju rolniczych elektrociepłowni biogazowych w Polsce i Europie
Development prospects for agricultural biogas heat and power generation plants in Poland and Europe
Autorzy:
Butlewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/239202.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
rolnicza elektrociepłownia biogazowa
obieg ORC
ogniwo paliwowe
agricultural biogas heat
power plant
ORC cycle
fuel cell
Opis:
W artykule omówiono podstawowe zagadnienia, dotyczące budowy rolniczych elektrociepłowni biogazowych. Przedstawiono możliwości zwiększenia efektywności elektrycznej elektrociepłowni przez zastosowanie obiegów ORC oraz Kalina. Wskazano na możliwości stosowania różnorodnych urządzeń do zamiany energii chemicznej biogazu na pracę mechaniczną, wśród których przedstawiono turbinę parową, silnik spalinowy oraz wysokotemperaturowe węglanowe ogniwo paliwowe. Stwierdzono, że na obszarach wiejskich należy spodziewać się zapotrzebowania na elektrociepłownie biogazowe o mocy 0,25-2,0 MWe oraz pracujące w systemie pozasieciowym instalacje o mocy 15-150 kWe. Projektowane elektrociepłownie powinny mieć możliwość jak największej produkcji energii elektrycznej z wykorzystaniem ciepła użytkowego i odpadowego. Wskazano na pilną potrzebę prowadzenia badań, wynikającą z zapotrzebowania rynku w Polsce i Europie na budowę nowoczesnych rolniczych elektrociepłowni biogazowych, o wysokiej efektywności.
Paper discussed the main issues regarding agricultural biogas power and heat generation plants. The possibilities of increasing electric energy efficiency of heat and power plants by additional application of the ORC and Kalina cycles, were presented. The chances of using different kinds of installations for converting biogas chemical energy into mechanical work were indicated. Among them, the steam turbine, combustion engine and high-temperature carbonate fuel cell were described. It was stated that on the rural areas the demand for biogas heat and power plants of 0.25-2.0 MWe, as well as for the installations working in outside-network system of 15-150 kWe, should be expected. Designed heat and power plants ought to be able to generate as much as possible electric energy, with the use of usable and waste heat, either. Paper emphasized an urgent necessity of carrying out the research works concering development of agricultural biogas heat and power plants of high efficiency, as resulted from the Polish and European market demands.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 2, 2; 137-147
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Approach to Impact Assessment of the Rated Power Uprate of NPP Unit on the Service Life of the Turbine Critical Elements
Autorzy:
Chernousenko, Olga
Nikulenkova, Tetyana
Peshko, Vitaliy
Nikulenkov, Anatolii
Powiązania:
https://bibliotekanauki.pl/articles/1811575.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nuclear power plant
reliability
turbine
steam flow
computational fluid dynamics
high pressure rotor
service life
long-term strength
low cycle fatigue
Opis:
Nuclear power plants play an important role in power systems of many countries. Ability to reasonable increase installed capacity of nuclear power units allow to reduce the cost for building of new power plants. When increasing NPP capacity to 104% there is a need to estimate the residual life of plant’s typical elements and continue their operation. The mathematical model of estimation of service life indicators of steam turbine K-1000-60/3000 is developed. The effect of increasing the capacity of a nuclear reactor on the heat transfer coefficients of a steam in the nozzle segments of high-pressure cylinder was established by using CFD modeling. The thermal and stress-strain state of the high-pressure rotor for the most typical operating modes are calculated. Using the correlation dependences of low-cycle fatigue, the rate of accumulation of cyclic damage of the base metal is established. The resistance of the metal to the exhaustion of long-term strength is also determined. On the example of the high pressure rotor of the 3rd power unit of Rivne NPP the service life indicators are calculated. The validity of increasing the installed capacity of the power unit was also confirmed.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 1; 105-116
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza mocy i sprawności układu kogeneracyjnego turbiny gazowej i parowej
The Comparative Study on Selected Operation Parameters of a Combined Cycle Plant
Autorzy:
Chinhenha, A.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/947654.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Morski w Gdyni. Wydawnictwo Uniwersytetu Morskiego w Gdyni
Tematy:
obieg gazowo-parowy
moc elektryczna i sprawność całkowita obiegu
model analityczny
badania symulacyjne
analiza parametrów
combined cycle plant
electric power and total efficiency
analytical model
simulation research
parameters analysis
Opis:
Przedmiotem pracy są badania symulacyjne i analiza wybranych parametrów siłowni pracującej w obiegu gazowo-parowym. Celem pracy jest opracowanie metodyki oceny mocy i sprawności siłowni z turbinami pracującymi w obiegu gazowo-parowym z wykorzystaniem autorskiego modelu analitycznego rozważanej instalacji. Uzyskane na podstawie przyjętego modelu szacunkowe wartości mocy i sprawności siłowni porównano z wynikami uzyskanymi podczas testów odbiorczych przykładowej instalacji, przeprowadzonych przez jedno z wiodących konsorcjów, działających w obszarze systemów wytwarzania energii (SIEMENS AG. Power Generation Group).
This paper deals with analysis and simulation research of selected parameters of combined cycle plant. Presented work is focused on elaboration of the evaluation methodology of power and efficiency of combined cycle plant based on the author’s analytical model of considered installation. The estimated values of power and efficiency obtained on the basis of the elaborated model have been compared with the results obtained during the final tests of the exemplary installations carried out by the one of the leading producers of the systems in the power generation field.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Gdyni; 2018, 103; 26-42
1644-1818
2451-2486
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Gdyni
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of energy potential of three ways of configuration of a condenser power plant thermal cycle
Autorzy:
Chmielniak, T.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258540.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Comparative analysis of energy
condenser
power plant
thermal cycle
new regeneration
separation preheater
Opis:
A theoretical, comparative analysis of three configuration ways of a condenser power plant thermal cycle is shown in the work. A new regeneration & separation preheater and its application in a thermal cycle is presented. Results obtained allow to compare all three analysed configurations efficiencies.
Źródło:
Polish Maritime Research; 2008, 4; 30-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies