Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power cycle" wg kryterium: Temat


Wyświetlanie 1-59 z 59
Tytuł:
Imperatives of European Security at Russia’s Critical Point on its Power Cycle
Autorzy:
Doran, Charles F.
Powiązania:
https://bibliotekanauki.pl/articles/2091760.pdf
Data publikacji:
2020-06-25
Wydawca:
Uniwersytet Warszawski. Wydział Nauk Politycznych i Studiów Międzynarodowych
Tematy:
conflict
power
foreign policy role
power cycle
world order
war
security
sphere of influence
Opis:
For the third time in the history of modern statecraft, Russia is attempting to climb its cycle of power relative to that of its rivals in the central international system. Under Vladimir Putin, Russia is seeking a larger foreign policy role. It has used force in Abkhazia, Georgia, Crimea, and Eastern Ukraine. Like the other authoritarian Great Power, China, Russia is trying to create a sphere of influence around itself. Yet the European Union is able to deter an expansionist Russia. But to better safeguard security, the EU needs to enhance its defense capability, to make its capability more interoperable with that of the United States, and to coordinate its defense effort across EU members. In strategic terms, NATO is fully able to obtain Russia’s respect and to supply an adequate deterrent to potential aggression.
Źródło:
Stosunki Międzynarodowe - International Relations; 2015, 51, 2; 93-105
0209-0961
Pojawia się w:
Stosunki Międzynarodowe - International Relations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of different organic fluids on performances of binary slag washing water power plants
Autorzy:
Li, Z.
Liu, Y.
Dong, P.
Zhang, Y.
Xiao, S.
Powiązania:
https://bibliotekanauki.pl/articles/240438.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
slag washing water
efficiency
organic fluids
binary power cycle
wydajność
płyn organiczny
podwójny cykl zasilania
Opis:
In this paper, 3 typical organic fluids were selected as working fluids for a sample slag washing water binary power plants. In this system, the working fluids obtain the thermal energy from slag washing water sources. Thus, it plays a significant role on the cycle performance to select the suitable working fluid. Energy and exergy efficiencies of 3 typical organic fluids were calculated. Dry type fluids (i.e., R227ea) showed higher energy and exergy efficiencies. Conversely, wet fluids (i.e., R143a and R290) indicated lower energy and exergy efficiencies, respectively.
Źródło:
Archives of Thermodynamics; 2017, 38, 3; 49-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating the Efficiency of Combined Cycle Power Plants with the Data Envelopment Analysis Process (with an Emphasis on Air Pollution)
Autorzy:
Sanjaranipour, Noushin
Atabi, Farideh
Momeni, Mansour
Ghodousi, Jamal
Lahijanian, Akramolmolok
Powiązania:
https://bibliotekanauki.pl/articles/2055783.pdf
Data publikacji:
2022
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
efficiency
Combined Cycle Power Plants
DEA
air pollution
Opis:
Performance management is one of the most significant strategies in promoting the efficiency of organizations and is highly sensitive. It is important to check the efficiency of combined cycle power plants because of their major contribution to power generation and air pollution. This study was conducted to evaluate the economic and environmental efficiency of Combined Cycle Power Plants (CCPPs). The inputs and outputs required to evaluate the performance of the power plants were determined according to expert opinions. Then, the 7-year statistics and information of the Qom, Neishabour, Shahid Rajaee, Yazd and Kerman power plants were collected as the desired CCPPs in Iran. The Window Data Envelopment Analysis (WDEA) method was used for evaluating the efficiency of the power plants. The 3-year window length showed that most of the power plants were efficient. Only the Rajaee, Neishabour and Yazd power plants were ineffective in some years. The mean efficiency of the power plants in the 4-year window length showed that the plants were efficient from 2008 to 2010.
Źródło:
Geomatics and Environmental Engineering; 2022, 16, 2; 111--125
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of a combined cycle power plant located in Jordan: A case study
Autorzy:
Bataineh, Khaled
Khaleel, Bara A.
Powiązania:
https://bibliotekanauki.pl/articles/240565.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
energy efficiency
exergy efficiency
exergy destruction
exergy losses
Opis:
Efficiency and electrical power output of combined cycle power plants vary according to the ambient conditions. The amount of these variations greatly affects electricity production, fuel consumption, and plant incomes. Obviously, many world countries have a wide range of climatic conditions, which impact the performance of power plants. In this paper, a thermodynamic analysis of an operating power plant located in Jordan is performed with actual operating data acquired from the power plant control unit. The analysis is performed by using first and second laws of thermodynamics. Energy and exergy efficiencies of each component of the power plant system are calculated and the effect of ambient temperature on the components performance is studied. The effects of gas turbine pressure ratio, gas turbine inlet temperature, load and ambient conditions on the combined cycle efficiency, power outputs and exergy destruction are investigated. Energy and exergy efficiencies of the combined cycle power plant are found as 45.29%, and 42.73% respectively when the ambient temperature is 34°C. Furthermore, it is found that the combustion chamber has the largest exergy destruction rate among the system components. The results showed that 73% of the total exergy destruction occurs in the combustion chamber when the ambient temperature is 34°C. Moreover, the results show that the second major exergy loss is in HRSC. The results show that the energy and exergy efficiency of the combined cycle power plant decreases as the ambient temperature increases. According to the calculation results, improvement and modification suggestions are presented.
Źródło:
Archives of Thermodynamics; 2020, 41, 1; 95-123
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of parallel hot windbox repowering on 387 MW fossil fuel power plant
Autorzy:
Harutyunyan, A.
Badyda, K.
Wołowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/175190.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
fossil boiler
hot windbox repowering
CO2 emissions
Opis:
The paper presents the concept of repowering in existing power plant. Among technologies for existing steam power plants, the hot windbox repowering is the fastest way to respond to the energy demand, improve efficiency and reduce the pollutants emissions. Thermodynamic analysis of power plant model with fossil boiler before and after hot windbox repowering, has been investigated using commercial software. The purpose of this work is to understand and analyze the effect of hot windbox repowering on 387 MW fossil fuel power plant as well as the effect of additional heat exchangers, which have been installed parallel with regeneration system to use the heat of boiler exhaust gases. In this way, after repowering the summary power of power plant in base load is 615 MW, which has been reached adding gas turbine (176.9 MW). To analyze the model, calculations were performed in 3 stages: 1) calculation and comparison of the thermodynamic parameters as well as carbon dioxide emissions of power plant model before and after repowering, 2) analysis of the optimal value of feed water mass flow through heat exchangers installed after economizer, 3) calculation of thermodynamic parameters in values 100%, 90%, 80% and 75% of fossil boiler heat loads.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 79-95
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The improvement of environmental characteristics of the combined cycle power plant by the implementation of the carbon capture installation
Autorzy:
Kotowicz, J.
Brzęczek, M.
Job, M.
Powiązania:
https://bibliotekanauki.pl/articles/134906.pdf
Data publikacji:
2015
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
combined cycle power plant
post-combustion technology
chemical absorption
carbon capture installation
power plant efficiency
ecological characteristics
Opis:
The paper describes a combined cycle power plant with carbon capture installation in a post-combustion technology. Carbon dioxide is separated from flue gas by using a chemical absorption method with monoethanolamine (MEA) as a sorbent. Separated carbon dioxide is compressed in order to prepare for transportation to the storage place. This paper identifies the electric efficiencies and other characteristic parameters of power plants before and after implementation of CO2 capture installation, as well as the power plant efficiency drop, and the improvement of ecological characteristics related to the implementation of this installation. The implementation of the installation described herein is associated with the efficiency loss caused by the auxiliary power for additional installations. The CO2 separation installation is powered by heat energy required for reclaiming the sorbent. This energy is taken in the form of steam extracted from the steam cycle, thus reducing the steam turbine power output, while the CO2 compression installation is powered by electric energy.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2015, 44 (116); 19-24
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Maximisation of Combined Cycle Power Plant Efficiency
Maksymalizacja sprawności elektrowni gazowo-parowych
Autorzy:
Kotowicz, J.
Job, M.
Brzęczek, M.
Powiązania:
https://bibliotekanauki.pl/articles/397508.pdf
Data publikacji:
2015
Wydawca:
ENERGA
Tematy:
combined cycle power plant
turbine cooling
thermodynamic optimisation
elektrownia gazowo-parowa
chłodzenie turbiny
optymalizacja
Opis:
The paper presents concepts for increasing the efficiency of a modern combined cycle power plant. Improvement of gas turbine performance indicators as well as recovering heat from the air cooling the gas turbine’s flow system enable reaching gross electrical efficiencies of around 65%. Analyses for a wide range of compressor pressure ratios were performed. Operating characteristics were developed for the analysed combined cycle plant, for different types of open air cooling arrangements of the gas turbine’s expander: convective, transpiration and film.
W artykule przedstawiono koncepcje zwiększenia sprawności nowoczesnej elektrowni gazowo-parowej. Poprawa charakterystyk pracy turbiny gazowej oraz wykorzystanie ciepła powietrza chłodzącego układ przepływowy turbiny gazowej pozwalają na osiągnięcie sprawności elektrycznej brutto rzędu 65%. Analizy przeprowadzono w szerokim zakresie stopni sprężania w kompresorze. Sporządzono główne charakterystyki pracy analizowanego układu gazowo-parowego dla różnych typów chłodzenia otwartego powietrzem ekspandera turbiny gazowej: konwekcyjnego, transpiracyjnego oraz błonowego.
Źródło:
Acta Energetica; 2015, 4; 42-53
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergetic diagnostics of a gas-and-steam power plant
Diagnostyka egzergetyczna elektrowni gazowo-parowej
Autorzy:
Stanek, Wojciech
Simla, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/396720.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
combined cycle power plant
exergetic analysis
mathematical model
elektrownia gazowo-parowa
diagnostyka egzergetyczna
model matematyczny
Opis:
Evaluation of thermodynamic efficiency of a power plant is usually performed using the method of so-called thermal diagnostics, based on energy balancing. Energetic analysis is however suitable only for a quantitative assessment and for comparing similar technologies. In order to properly assess the origins of energy losses in the given system, an exergetic analysis has to be applied. The paper describes the rules of exergetic diagnostics, which greatly extends the potential of classic thermal diagnostics. A calculation example of a combined cycle power plant is included. The example demonstrates the potential of exergetic diagnostics for locating exergy losses and explains the reasons for increased consumption of fuels by comparing two working conditions of the system: reference and operational.
W praktyce do oceny efektywności termodynamicznej działania elektrowni lub elektrociepłowni stosuje się narzędzia tak zwanej diagnostyki cieplnej opartej na bilansowaniu energetycznym. Analiza energetyczna nadaje się jednak wyłącznie do oceny ilościowej oraz porównywania podobnych technologii energetycznych. Dla prawidłowej oceny miejsc i przyczyn powstawania strat w systemach energetycznych konieczne jest zastosowanie analizy egzergetycznej. W artykule zaprezentowano zasady diagnostyki egzergetycznej, znacznie poszerzającej potencjał klasycznej diagnostyki cieplnej wraz z przykładem obliczeniowym dotyczącym elektrowni gazowo-parowej. Diagnostyka egzergetyczna jest techniką z zakresu zaawansowanej analizy egzegetycznej, pozwalającą na szczegółową detekcję przyczyn generowania strat w komponentach z uwzględnieniem tak zwanych przyczyn wewnątrzpochodnych i zewnątrzpochodnych. Procedury diagnostyki egzergetycznej, w połączeniu z technikami modelowania matematycznego, pozwalają na poszerzoną kontrolę eksploatacji procesów i systemów produkcyjnych. Ponadto umożliwiają one dekompozycję kosztu egzergetycznego pomiędzy składowe wynikające z wzajemnych powiązań pomiędzy komponentami systemu. Zaprezentowany przykład obliczeniowy dotyczący elektrowni gazowo-parowej prezentuje potencjał diagnostyki egzergetycznej w zakresie lokalizacji strat egzergii i wyjaśnia przyczyny zwiększonego zużycia zasobów zasilających system poprzez porównanie dwóch stanów: referencyjnego oraz dowolnego stanu eksploatacyjnego systemu.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 1; 1-17
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of an innovative steam turbine power plant with oxy-methane combustors
Autorzy:
Kindra, Vladimir Olegovich
Osipov, Sergey Konstantinovich
Zlyvko, Olga Vladimirovna
Shcherbatov, Igor Alexandrovich
Sokolov, Vladimir Petrovich
Powiązania:
https://bibliotekanauki.pl/articles/1955067.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Combined cycle power plant
carbon capture
storage system
precombustion capture
post-combustion capture
oxy-fuel combustion
Opis:
The Rankine cycle steam turbine power plants make a base for world electricity production. The efficiency of modern steam turbine units is not higher than 43–45%, which is remarkably lower compared to the combined cycle power plants. However, an increase in steam turbine power plant efficiency could be achieved by the rise of initial cycle parameters up to ultra-supercritical values: 700–780◦C, 30–35 MPa. A prospective steam superheating technology is the oxy-fuel combustion heating in a sidemounted combustor located in the steam pipelines. This paper reviews thermal schemes of steam turbine power plants with one or two side-mounted steam superheaters. An influence of the initial steam parameters on the facility thermal efficiency was identified and primary and secondary superheater parameters were optimized. It was found that the working fluid superheating in the side-mounted oxy-methane combustors leads to an increase of thermal efficiency higher than that with the traditional boiler superheating in the initial temperature ranges of 700–780◦C and 660–780◦C by 0.6% and 1.4%, respectively.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 123-140
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis of cycle arrangements of the coal-fired thermal power plants with carbon capture
Autorzy:
Kindra, Vladimir Olegovich
Milukov, Igor Alexandrovich
Shevchenko, Igor Vladimirovich
Shabalova, Sofia Igorevna
Kovalev, Dmitriy Sergeevich
Powiązania:
https://bibliotekanauki.pl/articles/1955057.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combined cycle power plant
carbon capture
storage system
precombustion capture
post-combustion capture
oxy-fuel combustion
Opis:
The electricity production by combustion of organic fuels, especially coal, increases the atmospheric CO2 content, which contributes to global warming. The greenhouse gas emissions by the power production industry may be reduced by the application of CO2 capture and storage systems, but it remarkably decreases the thermal power plant (TPP) efficiency because of the considerable increase of the auxiliary electricity requirements. This paper describes the thermodynamic analysis of a combined cycle TPP with coal gasification and preliminary carbon dioxide capture from the syngas. Utilization of the heat produced in the fuel preparation increases the TPP net efficiency from 42.3% to 47.2%. Moreover, the analysis included the combined cycle power plant with coal gasification and the CO2 capture from the heat recovery steam generator exhaust gas, and the oxy-fuel combustion power cycle with coal gasification. The coal-fired combined cycle power plant efficiency with the preliminary CO2 capture from syngas is 0.6% higher than that of the CO2 capture after combustion and 9.9% higher than that with the oxy-fuel combustion and further CO2 capture. The specific CO2 emissions are equal to 103 g/kWh for the case of CO2 capture from syngas, 90 g/kWh for the case of CO2 capture from the exhaust gas and 9 g/kWh for the case of oxy-fuel combustion.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 103-121
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A complex use of the materials extracted from an open-cast lignite mine
Wielorakie wykorzystanie minerałów wydobywanych z odkrywkowej kopalni lignitu
Autorzy:
Buryan, P.
Bucko, Z.
Mika, P.
Powiązania:
https://bibliotekanauki.pl/articles/219656.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
węgiel
gazyfikacja
czyste technologie węglowe
elektrownia o cyklu mieszanym
coal
gasification
clean coal technology
combined cycle power plant
Opis:
The company Sokolovská uhelná, was the largest producer of city gas in the Czech Republic. After its substitution by natural gas the gasification technology became the basis of the production of electricity in the combine cycle power plant with total output 400 MW. For the possibility of gasification of liquid by- -products forming during the coal gasification a entrained-flow gasifier capable to process also alternative liquid fuels has been in installed. The concentrated waste gas with these sulphur compounds is conducted to the desulphurisation where the highly desired, pure, 96 % H2SO4 is produced. Briquettable brown coal is crushed, milled and dried and then it is passed into briquetting presses where briquettes, used mainly as a fuel in households, are pressed without binder in the punch under the pressure of 175 MPa. Fine brown coal dust (multidust) is commercially used for heat production in pulverized-coal burners. It forms not only during coal drying after separation on electrostatic separators, but it is also acquired by milling of dried coal in a vibratory bar mill. Slag from boilers of classical power plant, cinder form generators and ashes deposited at the dump are dehydrated and they are used as a quality bedding material during construction of communications in the mines of SUAS. Fly ash is used in building industry for partial substitution of cement in concrete. Flue gases after separation of fly ash are desulphurized by wet limestone method, where the main product is gypsum used, among others, in the building industry. Expanded clays from overburdens of coal seams, that are raw material for the production of “Liapor” artificial aggregate, are used heavily. This artificial aggregate is characterized by outstanding thermal and acoustic insulating properties.
Przedsiębiorstwo Sokolovska uhelna jest największym producentem gazu miejskiego w Republice Czeskiej. Po jego zastąpieniu przez gaz ziemny, technologia gazyfikacji stała się podstawą do produkcji elektryczności w elektrowni o cyklu mieszanym o całkowitej mocy wyjściowej 400 MW. W celu umożliwienia gazyfikacji ciekłych produktów ubocznych gazyfikacji węgla, zainstalowano na drodze przepływu generator gazu, umożliwiający przetwarzanie alternatywnych paliw ciekłych. Skoncentrowany gaz odlotowy zawierający związki siarki odprowadzany jest do instalacji odsiarczającej, gdzie produkowany jest cenny produkt H2SO4, o wysokim stopniu czystości (96%). Węgiel brunatny nadający się do produkcji brykietów jest kruszony, mielony i suszony, następnie przechodzi przez proces brykietowania w odpowiednich prasach, gdzie formowane są brykiety, poprzez ich sprasowanie pod ciśnieniem 175 MPa. Brykiety takie wykorzystywane są powszechnie jako paliwo w gospodarstwach domowych. Drobnoziarniste pyły węgla brunatnego (paliwa pyłowe) wykorzystywane są na skalę komercyjną do produkcji ciepła w paleniskach pyłowych. Pyły węglowe powstają nie tylko w trakcie suszenia węgla po procesie oddzielania w separatorach elektrostatycznych, lecz także w procesie mielenia suszonego węgla w młynach wibracyjnych. Żużel z kotłów w konwencjonalnej elektrowni, popioły z generatorów oraz te osadzające się w instalacji podlegają wysuszeniu, następnie wykorzystywane są jako wysokiej jakości materiał na podłoże w różnorodnych instalacjach. Popioły lotne wykorzystywane są przemyśle budowlanym jako częściowe zamienniki cementu. Po oddzieleni popiołu lotnego, gazy wylotowe kierowane są do instalacji odsiarczania z wykorzystaniem technologii wilgotnego wapienia, w wyniku tego procesu powstaje gips, wykorzystywany, miedzy innymi, w przemyśle budowlanym. Glinki z warstw nadkładu nad pokładami węgla wykorzystywane są powszechnie jako surowiec do produkcji sztucznego kruszywa "Liapor", wykazującego wyjątkowe właściwości termiczne i dźwiękoizolacyjne.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1107-1118
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hierarchiczne dwuobiegowe gazowo-gazowe i gazowo-parowe elektrownie i elektrociepłownie jądrowe z wysokotemperaturowymi reaktorami i helem oraz wodą i parą jako czynnikami obiegowymi
Autorzy:
Bartnik, Ryszard
Powiązania:
https://bibliotekanauki.pl/articles/2080420.pdf
Data publikacji:
2021
Wydawca:
Nowa Energia
Tematy:
paliwo
energetyka
elektrownia gazowa
elektrownia gazowo-parowa
elektrociepłownia jądrowa
reaktor wysokotemperaturowy
fuel
power engineering
gas power plant
combined cycle power plant
nuclear power plant
high temperature reactor
Opis:
Celem artykułu jest przedstawienie innowacyjnych technologii energetycznych elektrowni i elektrociepłowni jądrowych, w których realizowane są dwa obiegi w układzie hierarchicznym.
Źródło:
Nowa Energia; 2021, 5/6; 20--37
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza termoekonomiczna wybranych układów gazowo–parowych
Termoeconomic analysis of Combine Cycle Power Plant
Autorzy:
Bernard, Aleksandra
Powiązania:
https://bibliotekanauki.pl/articles/101733.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska. Wydział Inżynierii Środowiska i Energetyki. Instytut Techniki Cieplnej
Tematy:
układy gazowo-parowe
turbina gazowa
analiza termodynamiczna
analiza ekonomiczna
EBSILON®Professional
combined cycle power plant
thermodynamic analysis
economic analysis
Opis:
W niniejszej pracy przedstawiono wyniki analizy termodynamicznej oraz ekonomicznej dla wybranych układów gazowo–parowych. Pierwszym rozpatrywanym układem był układ jednociśnieniowy, następnym układ jednociśnieniowy z modernizacją w postaci upust regeneracyjnego i przegrzewu oraz układ dwuciśnieniowy. Wymienione układy przeanalizowano z punktu widzenia zmieniającej się temperatury oraz ciśnienia spalin na wlocie do turbiny. Na potrzeby analizy wybrano cztery lokalizacje mieszczce się w różnych rejonach świata i na ich podstawie wyznaczono zależność sprawności układu od zmiany parametrów otoczenia, przy uwzględnieniu zmiany ciśnienia spalin na dolocie do turbiny gazowej. Kolejnym etapem pracy było wyznaczenie opłacalności finansowej każdego z układów oraz wyznaczenie wskaźników oceny efektywności ekonomicznej. Zostały wyznaczone wskaźniki ekonomiczne takie jak: wartość bieżąca netto, wskaźnik wartości bieżącej netto, wewnętrzna stopa zwrotu oraz zdyskontowany czas zwrotu. Analiza termodynamiczna została przeprowadza przy użyciu komercyjnego oprogramowania EBSILON®Professional (STEAG GmbH).
This work describes thermoeconomical analysis of combined cycle power plant. First analysed configuration is single pressure combined cycle power plant. Next is single pressure combined cycle with modernisation containing heat recovery and additional superheating. Closing structure is dual pressure combined cycle. These power plants were tested due to changing of the temperature and pressure at the inlet to the gas turbine. The next step was selection four locations in different parts of the world. The impact of the changing parameters of the environment on the efficiency of the system was determined. The financial viability of power plant was examined. The indicators of economic efficiency was computed such as NPV, NPVR, IRR and DPB. EBSILON®Professional was used as a program to creation of combined cycle power plants.
Źródło:
Archiwum Instytutu Techniki Cieplnej; 2016, 2; 5-33
2451-277X
Pojawia się w:
Archiwum Instytutu Techniki Cieplnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of rest interval between plyometric training sessions on functional performance tests
Autorzy:
Asadi, Abbas
Powiązania:
https://bibliotekanauki.pl/articles/1031770.pdf
Data publikacji:
2015
Wydawca:
PPHU Projack Jacek Wąsik
Tematy:
explosive power
sand
shortening cycle
Opis:
The purpose of this study was to examine the effects of short-term plyometric depth jump training on sand interposed with 48 hours or 72 hours of rest between training sessions on power type muscular adaptations in recreationally physical active men. Fifteen collegiate physical active men, who were familiar with plyometric exercise, participated in this study and were randomly divided into 2 groups: plyometric training with 48 h (PT48, N=7) and 72 h (PT72, N=8) of rest between training sessions. Pre and post training on sand, participants were measured in vertical jump (VJ), standing long jump (SLJ), agility t Test (TT), 20 and 40 m sprints, and one repetition maximum leg press (1RMLP). The plyometric training program on sand was applied during 6 weeks, 2 sessions per week, with 5 sets of 20 repetitions depth jump exercise from 45 cm box height. After completing 6 weeks training period, the PT48 and PT72 groups showed significant improvement in all performance tests (p<0.05), with statistically significant differences between treatments in TT and 40 m sprint time. With regard to significant differences in TT and 40 m sprint for PT72 compared with PT48 and greater improvements for PT72 in all tests, it can be recommend that coaches, strength and conditioning professionals apply 72 h rest between plyometric training sessions when sand surface was used.
Źródło:
Physical Activity Review; 2015, 3; 1-10
2300-5076
Pojawia się w:
Physical Activity Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Siłownia parowa z wieloźródłowym zasilaniem
Vapour power plant utilizing multiple energy sources
Autorzy:
Nowak, W.
Wiśniewski, S.
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/173152.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
siłownia parowa
siłownia ORC jednobiegowa
siłownia binarna
obliczenia cieplno-przepływowe
vapour power plant
single cycle ORC power plant
binary power plant
thermal and flow calculations
Opis:
W pracy przedstawiono wyniki obliczeń umożliwiające ocenę efektywności pracy siłowni parowej obejmującej jednoobiegową siłownię ORC (organic Rankine cycle) z parowaczem o cyrkulacji wewnętrznej, sprzężonej cieplnie z dolnym obiegiem siłowni binarnej. Rozpatrywane zagadnienie dotyczy wykorzystania dwóch różnotemperaturowych źródeł ciepła do zasilania obiegów organicznych analizowanego układu. Nośnikami energii pomiędzy źródłami ciepła a obiegiem jednoobiegowej siłowni ORC oraz dolnym obiegiem siłowni binarnej są odpowiednie strumienie wody. Omówione rozwiązanie polegające na zastosowaniu w jednoobiegowej siłowni ORC parowacza z cyrkulacją wewnętrzną nośnika energii, który umożliwia dostosowanie temperatury strumienia wody opuszczającej parowacz do wartości odpowiadającej temperaturze strumienia wody zasilającej podgrzewacz dolnego obiegu siłowni binarnej. W związku z tym możliwe jest skierowanie części strumienia wody zasilającej siłownię jednoobiegową do podgrzewacza dolnego obiegu siłowni binarnej. Podano przykłady obliczeniowe potwierdzające korzyści płynące z takiego rozwiązania.
In the paper, calculation results are presented to enable an assessment of the effectiveness of the vapour power plant that consists of the single cycle ORC power plant incorporating the evaporator with internal circulation and of the bottoming binary power plant, whereby the latter two power plants are thermally coupled, but are driven by two heat sources with different temperatures. Water is used as heat carrier from both the heat sources. The ORC power plant solution with the evaporator, that works with the internal circulation is presented in detail. Evaporator of this type enables to adjusted its outlet water temperature to the value of the temperature of the heat carrier delivered to the bottoming binary power plant, whereby part of the evaporator outlet water can be supplied to the preheater of that plant. Advantages of the above solution are confirmed by the results of the calculated exemplary cases.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 103-112
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The cooling rate of the heated vapor compression cycle in case of using refrigerants R134a, R22, and R600a
Autorzy:
Abd-Elhady, Mohamed Salama
Melad, Emmanoueil Bishara
Abd-Elhalim, Mohamed
Seif Alnasr, Ahmed
Powiązania:
https://bibliotekanauki.pl/articles/1845463.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
compression
cycle
power saving
refrigerant
refrigerating cycle
cooling rate
Opis:
The most power consuming part in the vapor compression cycle (VCC) is the gas compressor. Heating the refrigerant under constant volume after the compressor increases the condenser pressure, which consequently increases the cooling rate of the VCC. This study examined the influence of heating different refrigerants, i.e. R143a, R22, and R600a on the cooling rate of the VCC. Four experiments have been performed: the first experiment is a normal VCC, i.e. without heating, while in the second, third, and fourth experiments were carried out to raise the temperature of the refrigerant to 50◦C, 100◦C, and 150◦C. It has been found that heating raises the refrigerant pressure in VCC and thereby improves the refrigerant’s mass flow rate resulting in an improvement in the cooling power for the same compressor power. Heating the refrigerant after the mechanical compressor increases the temperature of the condenser as well as the temperature of the evaporator when using refrigerant R134a, which prevents the refrigeration cycle to be used in freezing applications, however using refrigerant R22 or refrigerant R600a promotes the heated VCC to be used in freezing applications. Refrigerant R600a has the lowest operating pressure compared to R134a and R22, which promotes R600a to be used rather than R134a and R22 from a leakage point of view.
Źródło:
Archives of Thermodynamics; 2021, 42, 2; 11-30
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Impact of Energy Source on the Life-Cycle Assessment of Power-to-Liquid Fuels
Autorzy:
Alhyari, Maha
Al-Salaymeh, Ahmed
Irshidat, Mahmoud
Kaltschmitt, Martin
Neuling, Ulf
Powiązania:
https://bibliotekanauki.pl/articles/123121.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
power-to-liquid
life cycle assessment
Opis:
Power-to-liquid (PtL) fuels are a promising technology and alternative to biofuels and conventional fuels. In this work, the environmental impact of PtL was investigated using life cycle assessment (LCA) in order to see how the energy source used in producing the PtL affects the environmental impacts of the fuel. The electrolysis cell used was solid oxide electrolysis cell, and the pathway of CO2 provision was biomass power plant. Four scenarios of energy sources were compared; the first scenario involved the electricity from German grid and heat from chemical industry, the second one was the electricity from Saudi Arabia grid and heat from chemical industry, the third one concerned the electricity from wind turbine and heat from evacuated tube collector, and the fourth scenario was the electricity from photovoltaic and heat from evacuated tube collector. The result of the life cycle assessment showed that the PtL fuels have environmental benefits over the fossil reference only in the third and fourth scenarios where renewable electricity was used.
Źródło:
Journal of Ecological Engineering; 2019, 20, 4; 239-244
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametric analysis of the efficiency of the combined gas-steam turbine unit of a hybrid cycle for the FPSO vessel
Autorzy:
Serbin, Serhiy
Washchilenko, Nikolay
Dzida, Marek
Kowalski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/2033277.pdf
Data publikacji:
2021
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
combined-cycle
gas turbine
steam turbine
power plant
Opis:
A thermal diagram of the combined gas‒steam turbine unit of a hybrid cycle, which is an energy complex consisting of a base gas turbine engine with a steam turbine heat recovery circuit and a steam-injected gas turbine operating with overexpansion, is proposed. A mathematical model of a power plant has been developed, taking into consideration the features of thermodynamic processes of simple, binary, and steam-injected gas‒steam cycles. Thermodynamic investigations and optimization of the parameters of a combined installation of a hybrid cycle for the generation of electrical energy have been carried out. Three-dimensional calculations of the combustion chamber of a steam-injected gas turbine were carried out, which confirmed the low emissions of the main toxic components.
Źródło:
Polish Maritime Research; 2021, 4; 122-132
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design analysis of turbines for co-generating micro-power plant working in accordance with organic Rankine’s cycle
Autorzy:
Mikielewicz, J.
Piwowarski, M.
Kosowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/259369.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
micro power plant
microturbines
organic Rankine cycle
turbine design
Opis:
This paper presents results of a design analysis of turbines for co-generating micro-power plant working in accordance with organic Rankine’s cycle and using biofuel. The heat power range from 25 kW to 100 kW with corresponding available electric power from 2kW to 12kW, was considered. Designs of axial-flow turbines (single-stage and multi-stage ones, also those partially fed), radial-flow and axial-radial -flow ones, were analyzed. Particular variants of the solutions were compared to each other.
Źródło:
Polish Maritime Research; 2009, S 1; 34-38
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternative cogeneration thermodynamic cycles for domestic ORC
Autorzy:
Mikielewicz, D.
Wajs, J.
Mikielewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/185524.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microcogeneration
thermodynamic cycle
power generation
mikrokogeneracja
cykl termodynamiczny
wytwarzanie energii
Opis:
The Organic Flash Cycle (OFC) is suggested as a vapor power cycle that could potentially improve the efficiency of utilization of the heat source. Low and medium temperature finite thermal sources are considered in the cycle. Additionally the OFC’s aim is to reduce temperature difference during heat addition. The study examines 2 different fluids. Comparisons are drawn between the OFC and an optimized basic Organic Rankine Cycle (ORC). Preliminary results show that ethanol and water are better suited for the ORC and OFC due to higher power output. Results also show that the single flash OFC achieves better efficiencies than the optimized basic ORC. Although the OFC improves the heat addition exergetic efficiency, this advantage was negated by irreversibility introduced during flash evaporation.
Źródło:
Chemical and Process Engineering; 2018, 39, 1; 75--84
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Risk level analysis in the selected (initial) stage of the project life cycle
Autorzy:
Borecki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1841395.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
project management
risk management
life cycle
power engineering
electrical grid
Opis:
This paper focuses on the analysis of selected risks as part of investments in the power engineering at the initial (tender) stage of the life cycle in the context of the method of project management by the Contractor. The study was carried out on the basis of an analysis of over 500 tenders in the power engineering, from the last 5 years, taking into account future forecast data. The analysis carried out in this article was aimed at achieving specific and unique goals and results aimed at creating a useful product, which is the Contractor’s offer in the power engineering, taking into account the most significant risks. The result of this article is to support the project team in implementing risk management in the project at the tender stage. For this purpose, the risks with their basic parameters were defined, which allowed for the development of a risk matrix taking into account the data obtained in the tender procedures of leading electric power distributors. Based on the proposed risk quantification criteria, a list of remedial actions was prepared for all risk types listed in this article. In addition, the aspects of possible elimination/reduction of the impact of the most significant risks that occur at the analyzed stage of the investment life cycle were developed.
Źródło:
Management and Production Engineering Review; 2020, 11, 4; 104-112
2080-8208
2082-1344
Pojawia się w:
Management and Production Engineering Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Analysis of an Atkinson Cycle Engine under Effective Power and Effective Power Density Conditions
Autorzy:
Gonca, G.
Powiązania:
https://bibliotekanauki.pl/articles/1033412.pdf
Data publikacji:
2017-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
gasoline engine
Atkinson cycle
engine performance
power density
finite-time thermodynamics
Opis:
This study presents performance optimization of an Atkinson cycle engine using criteria named as effective power and effective power density conditions. The effects of design and operating parameters such as compression ratio, cycle pressure ratio, cycle temperature ratio, equivalence ratio, bore/stroke ratio, inlet temperature, inlet pressure, engine speed, friction coefficient, mean piston speed and stroke length, on the performance characteristics have been examined. Moreover, the energy losses have been determined as fuel energy and they have been classified as incomplete combustion losses, friction losses, heat transfer losses, and exhaust output losses. Realistic values of specific heats have been used depending on temperature of working fluid. The results of the study can be assessed as an engineering tool by the Atkinson cycle engine designers.
Źródło:
Acta Physica Polonica A; 2017, 132, 4; 1306-1313
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An optimization study on an eco-friendly engine cycle named as Dual-Miller cycle (DMC) for marine vehicles
Autorzy:
Gonca, G.
Powiązania:
https://bibliotekanauki.pl/articles/259357.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Dual-Miller cycle engine
engine performance
power density
finite-time thermodynamics
Opis:
The diesel engine is an indispensable part of technology and it is commonly used in land and marine vehicles. However, diesel engines release NOx emissions due to high combustion temperatures. They have harmful effects on the environment such as sources of photo-chemical fog and climate changes. Therefore, they must be reduced and limited. The Miller cycle application is a NOx control method and it is popular in the recent years to abate NOx produced from the internal combustion engines (ICEs). A performance investigation of a Dual-Miller cycle (DMC) engine in terms of power (PO), power density (PD) and effective efficiency (EE) has been performed using a new finite-time thermodynamics modeling (FTTM) in this study. The effects of engine design and operating parameters on the engine performance (EPER) have been examined. Additionally, the energy losses have been determined resulting from incomplete combustion (IC), friction (FR), heat transfer (HT) and exhaust output (EO). The results presented could be an essential tool for DMC marine engine designers.
Źródło:
Polish Maritime Research; 2017, 3; 86-98
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of a program for supercritical power plant calculations
Autorzy:
Kotowicz, J.
Łukowicz, H.
Bartela, Ł.
Michalski, S.
Powiązania:
https://bibliotekanauki.pl/articles/240731.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blok nadkrytyczny
cykl parowy
walidacja
steam cycle
supercritical power plant
validation
Opis:
This article describes the validation of a supercritical steam cycle. The cycle model was created with the commercial program GateCycle and validated using in-house code of the Institute of Power Engineering and Turbomachinery. The Institute's in-house code has been used extensively for industrial power plants calculations with good results. In the first step of the validation process, assumptions were made about the live steam temperature and pressure, net power, characteristic quantities for high- and low-pressure regenerative heat exchangers and pressure losses in heat exchangers. These assumptions were then used to develop a steam cycle model in GateCycle and a model based on the code developed in-house at the Institute of Power Engineering and Turbomachinery. Properties, such as thermodynamic parameters at characteristic points of the steam cycle, net power values and efficiencies, heat provided to the steam cycle and heat taken from the steam cycle, were compared. The last step of the analysis was calculation of relative errors of compared values. The method used for relative error calculations is presented in the paper. The assigned relative errors are very slight, generally not exceeding 0.1%. Based on our analysis, it can be concluded that using the GateCycle software for calculations of supercritical power plants is possible.
Źródło:
Archives of Thermodynamics; 2011, 32, 4; 81-89
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effective efficiency in car engine as a function of reduction ratio during energy-aying speed control
Autorzy:
Ubysz, A.
Powiązania:
https://bibliotekanauki.pl/articles/246247.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
power efficiency
driving cycle
effective engine efficiency
B. S. F. C.
load torque
Opis:
The study examines the effect of transformation ratio in power transmission system on engine efficiency as a function of passenger vehicle velocity (m = 1400 kg) with energy-saving vehicle drive. The study also presents working range in driving phases for energy-saving speed control up to 120 km/h for a simplified overall engine performance map for SI engine. Understanding of the presented considerations can be facilitated through relating with advantages of application of non-driving phases in low engine load phases (field 4 in overall engine performance map). Working points of SI engines in engine performance maps were divided in terms of energy-saving vehicle speed control into 4 ranges. Zone l is the most economic whereas zones 3 and 4 are the least energy-saving, which was also discussed by the author in other works. The study presents the location of engine working points in overall engine performance map during energy-saving vehicle speed control within the range of 30-120 km/h using two different 6-gear gearboxes. Working range for CI engine in simplified overall characteristics in truck, the impact of speed control upon fuel consumption in real traffic conditions, sum and difference characteristics of components of drive engine unitary power, area of maximal rise in overall engine efficiency after reduction of rotational speed, simplified SI engine performance maps, covering with economic zone of working point in energy-saving drive of vehicles are presented in the paper.
Źródło:
Journal of KONES; 2010, 17, 4; 547-552
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of energy potential of three ways of configuration of a condenser power plant thermal cycle
Autorzy:
Chmielniak, T.
Krzyślak, P.
Powiązania:
https://bibliotekanauki.pl/articles/258540.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
Comparative analysis of energy
condenser
power plant
thermal cycle
new regeneration
separation preheater
Opis:
A theoretical, comparative analysis of three configuration ways of a condenser power plant thermal cycle is shown in the work. A new regeneration & separation preheater and its application in a thermal cycle is presented. Results obtained allow to compare all three analysed configurations efficiencies.
Źródło:
Polish Maritime Research; 2008, 4; 30-36
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas-steam cycle as a source of energy for carbon dioxide capture from flue gases of a large coal power plant
Układ gazowo-parowy jako źródło energii dla układu wychwytu CO2 ze spalin bloku węgłowego dużej mocy
Autorzy:
Wójcik, K.
Lepszy, S.
Chmielniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/172837.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
układ gazowo-parowy
CO2
blok węglowy
gas-steam cycle
coal power plant
Opis:
Separation of carbon dioxide from flue gas carried by the chemical absorption is associated with a high energy demand for desorption process and increased demand for electricity. Satisfying these needs through the use of energy generated in the same power plant, where CO2 is emitted, has a significant influence on the parameters of the plant (reduction of power and decrease of the electricity generation efficiency). It examines the use of additional power source, serving on the need to install CO2 capture. The paper presents the technical and economic parameters of the combined system, formed from a power plant fueled by coal with the CO2 capture system that is associated with gas-steam cycle, producing energy for CO2 separation plant.
Separacja CO2 ze spalin przeprowadzana metodą absorpcji chemicznej wiąże się z dużym zapotrzebowaniem na energię cieplną (na cele desorpcji) oraz zwiększonym zapotrzebowaniem na energię elektryczną. Zaspokojenie tych potrzeb poprzez dostarczenie energii wytworzonej w bloku, dla którego przeprowadza się wydzielanie CO2 ze spalin, ma znaczny wpływ na parametry bloku (zmniejszenie mocy wytworzonej oraz spadek sprawności wytwarzania energii elektrycznej). Przeanalizowano wykorzystanie dodatkowego źródła energii, pracującego na potrzeby instalacji wychwytu CO2. W pracy przedstawiono parametry techniczne i ekonomiczne dla układu kombinowanego, powstałego z bloku węglowego z wychwytem CO2, skojarzonego z układem gazowo-parowym i wytwarzającego energię do instalacji separacji CO2.
Źródło:
Archiwum Energetyki; 2011, 41, 3-4; 15-28
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy bloku nadkrytycznego 900 Mwe współpracującego z obiegiem ORC
Thermodynamic analysis of the supercritical 900MWe power unit, co-operating with an ORC cycle
Autorzy:
Ziółkowski, P.
Mikielewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/172841.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
blok nadkrytyczny
obieg ORC
model numeryczny
supercritical power unit
ORC cycle
numerical model
Opis:
W pracy przedstawiono analizę termodynamiczną bloku nadkrytycznego o mocy 900 MWe współpracującego z obiegiem ORC (organic Rankine cycle). Wykonano symulacje numeryczne pracy siłowni dla warunków nominalnych określając jej moc i sprawność elektryczną. Ponadto przeanalizowano pracę bloku współpracującego z obiegiem ORC dla czterech czynników roboczych, tj.: propan, izobutan, pentan i etanol. W układzie ORC górne źródła ciepła stanowi woda z systemu odzysku ciepła o temperaturze 90 °C wspomagana ciepłem z upustu pary z turbiny parowej. Analizę wykonano za pomocą kodów numerycznych typu CFM.
The paper presents thermodynamic analysis of the supercritical 900 MWe power unit, cooperating with an ORC cycle. Numerical simulations of the power unit at its nominal operating conditions were conducted to compute its power and electric efficiency. Furthermore, operation of the power unit with an ORC medium was conducted for four types of the medium, i.e., propane, isobutene, pentane and ethanol. As a heat source for the ORC setup, water from the heat recovery system at the temperature of 90 °C supported with steam extracted from the steam turbine, was used. The analysis was performed with use of CFM type numerical codes.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 165-174
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of thermodynamic cycles of selected nuclear ship power plants with hightemperature helium- cooled nuclear reactor
Autorzy:
Szewczuk-Krypa, N.
Grzymkowska, A.
Głuch, J.
Powiązania:
https://bibliotekanauki.pl/articles/260189.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
nuclear ship power plant
nuclear reactor
HTGR
gas turbine
steam turbine
combined cycle
Opis:
This paper presents a comparative analysis of thermodynamic cycles of two ship power plant systems with a hightemperature helium- cooled nuclear reactor. The first of them is a gas system with recuperator , in which classical gas chamber is substituted for a HTGR reactor (High Temperature Gas-cooled Reactor) . The second of the considered cycles is a combined gas-steam system where working medium flux from gas turbine outlet is directed into waste heat boiler and its heat is utilized for production of superheated steam to drive steam turbine. Preliminary calculations of the combine cycles showed that it is necessary to expand the system by adding to its steam part an inter-stage overheat for secondary steam, owing to that a required degree of steam dryness at outlet from the turbine can be reached, ensuring its correct operational conditions. The analyzed power systems were compared to each other with regard to efficiency of their thermodynamic cycles. Also, efficiency of particular cycles were subjected to optimization in respect to such parameters as : working gas temperature at outlet from reactor in gas system as well as steam pressure at outlet from waste heat boiler and partition pressure in steam part of combined system. Advantages of nuclear power plants compared with the classical power systems dominating currently in sea transport were also discussed.
Źródło:
Polish Maritime Research; 2018, S 1; 218-224
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applying the life cycle assessment method to an analysis of the environmental impact of heat generation
Autorzy:
Dzikuć, M.
Powiązania:
https://bibliotekanauki.pl/articles/955269.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
energia
ekologia
ciepło
elektrownia
life cycle assessment (LCA)
energy
ecology
heat
power plant
Opis:
The paper presents a method of Life Cycle Assessment (LCA) to determine the impact of the heat produced on the environment. In addition, the usefulness of this method to assess the energy sector has been shown. This paper presents the impact of heat generation on the environment in coal power plants. A detailed analysis by the method of LCA is made to compare the environmental impact of heat generation in the Legnica Power Plant and Polkowice Power Plant. It is pointed to the difference in the results obtained. Moreover, the causes of the reported environmental impacts are discussed. Measures are identified which will help to reduce in the future the impact of the electricity produced on the environment during the production of heat.
Źródło:
International Journal of Applied Mechanics and Engineering; 2013, 18, 4; 1275-1281
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison analysis of blade life cycles of land-based and offshore wind power plants
Autorzy:
Tomporowski, A.
Piasecka, I.
Flizikowski, J.
Kasner, R.
Kruszelnicka, W.
Mroziński, A.
Bieliński, K.
Powiązania:
https://bibliotekanauki.pl/articles/259804.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
life cycle assessment (LCA)
wind power plant blades
post-consumer reuse of materials
offshore wind power plants
Ekowskaźnik 99
Opis:
In recent years, the offshore wind power industry has been growing dynamically. A key element which decides upon power output of a wind power plant is blades. They are most frequently produced from polymers – laminates with epoxy resins and fiberglass. In the near future, when the blade life cycles are over, large amounts of waste material of this type will have to be reused. This paper presents a comparison analysis of the impact of particular material existence cycle stages of land-based and offshore wind power plant blades on the environment. Two wind power plant blades, of about 49 m in length each, were examined using the LCA method, the programme SimaPro, and Ekowskaźnik 99 modelling (phase LCIA).
Źródło:
Polish Maritime Research; 2018, S 1; 225-233
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of heat recuperation in ORC power plant on efficiency of waste heat utilization
Autorzy:
Borsukiewicz-Gozdur, A.
Powiązania:
https://bibliotekanauki.pl/articles/240646.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nadkrytyczna siłownia organiczna
odzyskiwanie ciepła
heat recuperation
ORC
subcritical power plant
supercritical organic cycle
Opis:
The present work is devoted to the problem of utilization of the waste heat contained in the exhaust gases having the temperature of 350[degrees]C. Conversion of the waste heat into electricity using a power plant working with organic fluid cycles is considered. Three Organic Rankine Cycle (ORC) power plant solutions are analysed and compared: a solution with the basic, single thermodynamic conversion cycle, one with internal heat recuperation and one with external heat recuperation. It results from the analysis that it is the proper choice of the working fluid evaporation temperature that fundamentally affects the maximum of the ORC plant output power. Application of the internal heat recuperation in the plant basic cycle results in the output power increase of approx. 5%. Addition of the external heat recuperation to the plant basic cycle, in the form of a secondary supercritical ORC power cycle can rise the output power by approx. 2%.
Źródło:
Archives of Thermodynamics; 2010, 31, 4; 111-123
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of geothermal energy in co-generated heat and power production in Poland : a case study
Autorzy:
Mróz, Tomasz Maciej
Grabowska, Weronika
Powiązania:
https://bibliotekanauki.pl/articles/2073770.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cogenerated heat and power
CHP
organic rankine cycle
ORC
energy performance
CO2 emission
Opis:
The paper presents the results of energy and environmental evaluation of geothermal CHP plant. The variant of CHP plant based on Organic Rankine Cycle (ORC) has been taken into consideration as the most favorable for the geothermal conditions prevailing in Poland. The existing geothermal well located in the city of Konin in Greater Poland (Wielkopolska) voivodship has been chosen as the case study. The conceptual design of CHP plant has been proposed and evaluated from energy and environmental point of view. The non-renewable primary energy consumption has been chosen as energy performance criterion. In the case of environmental performance carbon dioxide emission has been taken as evaluation criterion. The analysis has been performed for different operating conditions and three working fluids. The best energy performance can be spotted for working fluid R123, for which the reduction varies between 15200 and 11900 MWh/a. The working fluid R134a has a worse energy performance, which allows for the reduction of fossil fuels energy consumption in the range of 15000 and 11700 MWh/a. The total reduction of CO2 emission is the highest for working fluid R123: 5300 to 4150 MgCO2/a, the medium one for working fluid R134a: 5200 to 4100 MgCO2/a and the lowest for working fluid R227: 5000 to 4050 MgCO2/a. It has been shown that the construction of geothermal CHP plants based on Organic Rankine Cycle can be reasonable solution in Polish conditions. It is important concerning the need of reduction of fossil fuels primary energy consumption and carbon dioxide emission.
Źródło:
Archives of Environmental Protection; 2021, 47, 3; 82--91
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Possibilities of Electricity Production in Flash Geothermal System in Poland
Ocena możliwości wytwarzania energii elektrycznej przy wykorzystaniu obiegów z separacją pary w polskich warunkach geotermalnych
Autorzy:
Barbacki, A.
Pająk, L.
Powiązania:
https://bibliotekanauki.pl/articles/385815.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
energia geotermalna
siłownie geotermalne
obieg z separacją pary
moc właściwa
Polska
geothermal energy
geothermal power plant
flash cycle
specific power
Polska
Opis:
Przedstawiono metodykę oceny dostępnej mocy jednostkowej (odniesionej do strumienia płynu geotermalnego) siłowni geotermalnej wykorzystującej obieg z separacją pary (ang. flash system). Analizy prowadzono, uwzględniając temperaturę kondensacji pary wychodzącej z turbiny przy różnej temperaturze złożowej. Zaproponowano metodykę optymalizacji ciśnienia separacji pary przy założeniu, że ekspansja pary w turbinie zachodzi izentropowo. Uwzględniając te założenia, opracowano analityczną zależność umożliwiającą ocenę optymalnej temperatury (której odpowiada optymalne ciśnienie), dla której powinien być prowadzony proces separacji pary i cieczy. Optymalizację prowadzono z zamiarem osiągnięcia maksymalnej mocy elektrycznej dostępnej dla określonego strumienia płynu geotermalnego. Prezentowane w artykule rozważania zostały zainicjowane badaniami dotyczącymi możliwości wykorzystania systemów ciepła gorących suchych skał HDR (ang. Hot Dry Rock) i geotermalnych systemów wspomaganych EGS (ang. Enhanced Geothermal System) do produkcji energii elektrycznej w polskich warunkach geotermalnych. W centralnej Polsce w utworach triasu dolnego przewiduje się możliwość eksploatacji płynów geotermalnych o temperaturze ponad 130°C. Jednak z uwagi na niewielką osiąganą moc elektryczną, w połączeniu z wysokimi przewidywanymi nakładami inwestycyjnymi (wspominane zasoby energii geotermalnej zalegają na głębokościach większych niż 4000 m), wykorzystanie tych systemów raczej nie będzie opłacalne. Zasoby te mogą zostać jednak efektywnie zagospodarowane do wytwarzania energii elektrycznej w siłowniach binarnych.
An analytical method is described that expresses the specific power of a flash geothermal power plant with flash temperature regarded as a variable. The analysis was carried out for a condensation temperature for fluid exiting a theoretical turbine and for a given geothermal reservoir temperature. The method is a linear approximation of the established method for optimizing separator pressure. This linear approximation makes it possible to obtain an analytical expression for the optimum fl ash temperature (fixing the separation pressure) at which the maximal specific power is obtained. A discussion arose in Poland during extensive research related to the application of binary systems, HDR (Hot Dry Rock), and EGS (Enhanced Geothermal System) technologies for the production of electricity. This concerned the hypothetical possibility of using geothermal flash systems for this purpose. Therefore, the above procedure was applied to Polish geothermal conditions to assess the theoretical possibilities of operating such systems at the reservoir temperatures anticipated in Poland. In the lower Triassic formations in central Poland, there are geothermal resources with temperatures hovering above 130°C. However, low net power values were estimated following the application of the procedure; when combined with the large investment costs involved (the high-temperature resources lie at a depth more than 4000 m), this is not condusive for the efficient application of such systems. On the other hand, the possible application of binary systems to electricity production in that area is realistic and justified.
Źródło:
Geomatics and Environmental Engineering; 2017, 11, 3; 17-29
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rational parameters of a hybrid geothermal power plant based on Flash/ORC cycles
Autorzy:
Redko, Andriy
Kulikova, Natalia
Ujma, Adam
Redko, Oleksandr
Burda, Yurii
Pivnenko, Yurii
Kompan, Artem
Powiązania:
https://bibliotekanauki.pl/articles/2065636.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
energia geotermalna
elektrownia
obieg termodynamiczny
symulacja numeryczna
geothermal energy
power plant
thermodynamic cycle
numerical simulation
Opis:
The numerical simulation results of the thermal scheme of a power plant related to steam and organic cycles are presented. The rational parameters of the cycles of the geothermal energy conversion unit have been determined. In addition, various organic working fluids are studied. The rational parameters of the thermodynamic cycles at a geothermal fluid temperature of 250°C have also been defined.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2021, 10, 1; 127--133
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Comparison of the Environmental Impact of Solar Power Generation Using Multicrystalline Silicon and Thin Film of Amorphous Silicon Solar Cells: Case Study in Thailand
Autorzy:
Khaenson, W.
Maneewan, S.
Punlek, C.
Powiązania:
https://bibliotekanauki.pl/articles/124685.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
solar power generation
life cycle assessment (LCA)
multicrystalline silicon solar cell
amorphous silicon solar cell
Opis:
This paper studies the environmental impact of two different forms of solar power generation in Thailand – that of multicrystalline silicon solar cells, and that of thin film amorphous silicon solar cells. It takes as its study two of the largest solar cell power plants of their kind in Thailand; a multicrystalline silicon plant in the north (generating 90 MW) and a thin film amorphous silicon plant in the centre (generating 55 MW). The Life Cycle Assessment tool (LCA) was used to assess the environmental impact of each stage of the process, from the manufacture of the cells, through to their transportation, installation and eventual recycling. The functional unit of the study was the generation of 1 kWh of power transmitted and distributed by the Electricity Generating Authority of Thailand (EGAT) and Provincial Electricity Authority (PEA). The environmental impact results were calculated in terms of eco-points (Pt) per functional unit of 1 kWh. The characterised data for 1 kWh of solar power generation was then compared with data for 1 kWh of combined cycle and thermal power generation (both in Thailand), using the same set of characterisation factors. After analyzing the results, both forms of solar power energy generation were found to impact upon the studied categories of Human Health, Ecosystem Quality and Resource Depletion, whilst also highlighting the importance of the solar cell module recycling process in decreasing the overall environmental impact. When the two solar cell technologies were compared, the overall impact of the multicrystalline silicon solar cell was found to be higher than that of the thin film amorphous silicon solar cell. Furthermore, when assessing the overall impact against non-renewable power generating technologies such as combined cycle and thermal power generation, the thin film amorphous silicon solar cells were found to have the lowest environmental impact of all technologies studied.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 1-14
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspektywy rozwoju rolniczych elektrociepłowni biogazowych w Polsce i Europie
Development prospects for agricultural biogas heat and power generation plants in Poland and Europe
Autorzy:
Butlewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/239202.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
rolnicza elektrociepłownia biogazowa
obieg ORC
ogniwo paliwowe
agricultural biogas heat
power plant
ORC cycle
fuel cell
Opis:
W artykule omówiono podstawowe zagadnienia, dotyczące budowy rolniczych elektrociepłowni biogazowych. Przedstawiono możliwości zwiększenia efektywności elektrycznej elektrociepłowni przez zastosowanie obiegów ORC oraz Kalina. Wskazano na możliwości stosowania różnorodnych urządzeń do zamiany energii chemicznej biogazu na pracę mechaniczną, wśród których przedstawiono turbinę parową, silnik spalinowy oraz wysokotemperaturowe węglanowe ogniwo paliwowe. Stwierdzono, że na obszarach wiejskich należy spodziewać się zapotrzebowania na elektrociepłownie biogazowe o mocy 0,25-2,0 MWe oraz pracujące w systemie pozasieciowym instalacje o mocy 15-150 kWe. Projektowane elektrociepłownie powinny mieć możliwość jak największej produkcji energii elektrycznej z wykorzystaniem ciepła użytkowego i odpadowego. Wskazano na pilną potrzebę prowadzenia badań, wynikającą z zapotrzebowania rynku w Polsce i Europie na budowę nowoczesnych rolniczych elektrociepłowni biogazowych, o wysokiej efektywności.
Paper discussed the main issues regarding agricultural biogas power and heat generation plants. The possibilities of increasing electric energy efficiency of heat and power plants by additional application of the ORC and Kalina cycles, were presented. The chances of using different kinds of installations for converting biogas chemical energy into mechanical work were indicated. Among them, the steam turbine, combustion engine and high-temperature carbonate fuel cell were described. It was stated that on the rural areas the demand for biogas heat and power plants of 0.25-2.0 MWe, as well as for the installations working in outside-network system of 15-150 kWe, should be expected. Designed heat and power plants ought to be able to generate as much as possible electric energy, with the use of usable and waste heat, either. Paper emphasized an urgent necessity of carrying out the research works concering development of agricultural biogas heat and power plants of high efficiency, as resulted from the Polish and European market demands.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 2, 2; 137-147
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ecological efficiency assessment model for environmental safety management of wind power plant
Autorzy:
Kasner, Robert
Flizikowski, Józef
Tomporowski, Andrzej
Kruszelnicka, Weronika
Idzikowski, Adam
Powiązania:
https://bibliotekanauki.pl/articles/88582.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
wind power plant
ecological efficiency
renewable energy
emission in life cycle
elektrownia wiatrowa
efektywność ekologiczna
energia odnawialna
Opis:
This study focuses on the evaluation of the benefits and ecological costs that occur in the life cycle of a wind power plant. The study constitutes an attempt to expand upon previously conducted research on the analysis of costs and benefits in the stages of production, operation and post-consumer management of wind turbines. The aim of the study adopted research methodology, analysis and assessment of the benefits and environmental impacts of the Vestas V90/105m 2 MW wind turbine throughout its life cycle. Original assessment indicators of the benefits and ecological costs occurring throughout a wind power plant’s life cycle for environmental safety management, were proposed and verified.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 371-377
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic analysis and analytical simulation of the Rallis modified Stirling cycle
Autorzy:
Ranjan, Ravi Kant
Verma, Suresh Kant
Powiązania:
https://bibliotekanauki.pl/articles/240284.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
rallis modified Stirling cycle engine
nonisothermal characteristics
power output
thermal efficiency
charakterystyki nieizotermiczne
moc użyteczna
sprawność cieplna
Opis:
A Stirling cycle was developed by Rallis considering the adiabatic behaviour instead of isothermal behaviour of working fluid inside the expansion/compression volume, since the isothermal processes are very difficult to be realised in actual practice due to irreversibilities. In order to increase the performance of Rallis Stirling cycle engine, two modified versions of Rallis Stirling cycle engine model have been proposed and developed, called as Rallis modified Stirling cycle engine (RMSE). In this paper, the thermodynamic analysis of the developed models have been carried out and the simulated results are compared with the Rallis ideal model of Stirling cycle engine, as this model describes more accurately the thermodynamic cycle of practical Stirling machines. The results reveal the fact that the thermal efficiency of RMSE I model is enhanced by 38.06% and that of RMSE II model by 48.42%, whereas the power output is increased by 58.05% and 78.19% in case of RMSE I and RMSE II model respectively, when compared with the Rallis ideal adiabatic model of Stirling engine.
Źródło:
Archives of Thermodynamics; 2019, 40, 2; 35-67
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vector operation of one-cycle controlled matrix rectifier
Autorzy:
Yang, X.
Jiang, J.
Powiązania:
https://bibliotekanauki.pl/articles/140502.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
matryca prostownika
jeden cykl kontroli
jednostkowy współczynnik mocy
matrix rectifier
one-cycle control
unitary power factor
vector operation
Opis:
In the paper an algorithm and computer code for the identification of the hysteresis parameters of the Jiles-Atherton model have been presented. For the identification the particle swarm optimization method (PSO) has been applied. In the optimization procedure five design variables has been assumed. The computer code has been elaborated using Delphi environment. Three types of material have been examined. The results of optimization have been compared to experimental ones. Selected results of the calculation for different material are presented and discussed. A novel vector operated one-cycle control matrix rectifier (OCC-MR) is proposed in this paper. Matrix rectifier (MR) is a generalized buck three-phase AC-DC converter with four-quadrant operation capability. MR can also be the front-stage circuit of AC-DC-AC equivalent structure of MC. One-cycle control (OCC) is a nonlinear control technique, which integrates modulation algorithm and control strategy. By applying OCC to current control loop, the OCC-MR achieves balance only in a switching cycle,and realizes unitary input power factor. Furthermore, vector operation of OCC results In minimum switching losses. In order to make up for the insufficiency of OCC on load disturbance suppression, a PID controller is added onto output voltage control to improve load regulation. The OCC-MR features great simplicity, fast dynamic response and good immunity on input disturbance. On the basis of theoretical analysis, a systematic simulation of OCC-MR is implemented by means of Matlab/Simulink. Both static state performance and dynamic state performance of OCC-MR are discussed deeply. The simulation results have proved theoretical analysis of the vector operation of OCC-MR, and the control effects are satisfactory.
Źródło:
Archives of Electrical Engineering; 2012, 61, 2; 149-164
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ na środowisko wytwarzania energii elektrycznej w elektrowniach opalanych węglem kamiennym
The impact of electricity production in coal-fired power plants on environment
Autorzy:
Urban, S.
Dzikuć, M.
Powiązania:
https://bibliotekanauki.pl/articles/908530.pdf
Data publikacji:
2013
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
ocena cyklu życia (LCA)
energia
ekologia
węgiel kamienny
elektrownia
life cycle assessment (LCA)
energy
ecology
coal
power plant
Opis:
Jedną ze skutecznych metod, która umożliwia ocenę i porównanie wpływu na środowisko wytwarzania energii elektrycznej w różnych elektrowniach bazujących na tym samym paliwie, jest ocena cyklu życia (Life Cycle Assessment – LCA). Analizie za pomocą tej metody mogą być poddawane zarówno produkty, procesy obejmujące pełny cykl życia produktu, jak również całe gałęzie przemysłu. W publikacji zostanie przeprowadzona analiza metodą LCA, która pozwoli na ocenę i porównanie wytwarzania energii elektrycznej w dwóch elektrowniach opalanych węglem kamiennym: Elektrowni Dolna Odra oraz Elektrowni Opole.
The paper presents a method of Life Cycle Assessment (LCA) to determine the impact of the electricity produced on the environment. In addition, the usefulness of this method has been proven in assessment of the energy sector. This paper presents the impact of electricity generation on the environment in coal power plants. A detailed analysis by the method of LCA to compare the environmental impact of electricity generation in the Dolna Odra power plant and the power plant Opole. The differences in results of the analysis were pointed so as the causes of occurring environmental impacts were discussed. Also the measures to help in reducing the impact of the electricity produced on the environment during the production of electricity in the future were described.
Źródło:
Ekonomia i Środowisko; 2013, 2; 84-92
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of effeciency of waste heat conversion in low-temperature Brayton cycle
Autorzy:
Borsukiewicz, A.
Stawicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/185192.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Brayton cycle
working fluid
low temperature source
low temperature power plant
Cykl Braytona
temperatura
elektrownia o niskiej temperaturze
Opis:
The paper discusses the feasibility, effectiveness and validity of a gas turbine power plant, operated according to the Brayton comparative cycle in order to develop low-potential waste heat (160◦C) and convert it into electricity. Fourteen working fluids, mainly with organic origin have been examined. It can be concluded that low molecular weight working fluids allow to obtain higher power efficiency of Brayton cycle only if conversions without taking into account internal losses are considered. For the cycle that takes into account the compression conversion efficiency in the compressor and expansion in the gas turbine, the highest efficiency was obtained for the perfluoropentane working medium and other substances with relatively high molecular weight values. However, even for the cycle using internal heat recovery, the thermal efficiency of the Brayton cycle did not exceed 7%.
Źródło:
Chemical and Process Engineering; 2018, 39, 1; 103--112
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic and economic analysis of a 900 MW ultra-supercritical power unit
Autorzy:
Łukowicz, H.
Dykas, S.
Rulik, S.
Stępczyńska, K.
Powiązania:
https://bibliotekanauki.pl/articles/240644.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
obieg pary
parametry apry
podwójne podgrzewanie
coal-fired power unit
double reheat
steam cycle
ultra-supercritical steam parameters
Opis:
The paper presents a thermal-economic analysis of different variants of a hard coal-fired 900 MW ultra-supercritical power unit. The aim of the study was to determine the effect of the parameters of live and reheated steam on the basic thermodynamic and economic indices of the thermal cycle. The subject of the study was the cycle configuration proposed as the "initial thermal cycle structure" during the completion of the project "Advanced Technologies for Energy Generation" with the live and reheated steam parameters of 650/670 [degrees]C. At the same time, a new concept of a thermal cycle for ultra-supercritical parameters with live and reheated steam temperature of 700/720 [degrees]C was suggested. The analysis of the ultra-supercritical unit concerned a variant with a single and double steam reheat. All solutions presented in the paper were subject to a detailed thermodynamic analysis, as well as an economic one which also included CO2 emissions charges. The conducted economic analysis made it possible to determine the maximum value of investment expenditures at which given solutions are pro.table.
Źródło:
Archives of Thermodynamics; 2011, 32, 3; 231-245
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water management at CCGT unit
Optymalizacja gospodarki wodą w bloku gazowo-parowym
Autorzy:
Szaban, J.
Wawrzyński, I.
Powiązania:
https://bibliotekanauki.pl/articles/276594.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
optymalizacja
Ovation
SmartProcess
chłodnia wentylatorowa
Cykl Kombinowany w Wysokosprawnej Kogeneracji
optimization
power plant
cooling towers
Combined Cycle Gas Turbine
Opis:
This paper discusses a water management optimization of cooling towers. Description of a problem solution as well as its industrial application is included. The used software belongs to Emerson's SmartProcess products. It has been applied to two power plants as a part of the Ovation DCS (distributed control system).
W artykule omówiono optymalizacje gospodarki wodnej w chłodni wentylatorowej. Podano opis rozwiązania problemem jak również jego zastosowania w przemyśle. Zastosowano część oprogramowania z pakietu SmartProcess dostarczanego przez Emerson. Pakiet użyto w dwóch elektrowniach, jako uzupełnienie rozproszonego systemu sterowania Ovation.
Źródło:
Pomiary Automatyka Robotyka; 2013, 17, 2; 250-253
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Air bottoming combined cycle performance analyses by the combined effect of variable parameters
Autorzy:
Khan, Mohammad N
Alzafiri, Dhare
Powiązania:
https://bibliotekanauki.pl/articles/27309845.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
topping cycle
air bottoming cycle
net power output
thermal efficiency
total exergy
destruction
exergetic efficiency
cykl uzupełniania
cykl opadania powietrza
moc wyjściowa netto
wydajność termiczna
całkowita egzergia
zniszczenie
efektywność egzergetyczna
Opis:
To meet the continuous demand for energy of industrial as well as commercial sectors, researchers focus on increasing the power generating capacity of gas turbine power plants. In this regard, the combined cycle is a better solution in terms of environmental aspects and power generation as compared to a simple gas turbine power plant. The present study is the thermodynamic investigation of five possible air bottoming combined cycles in which the topping cycle is a simple gas turbine cycle, regenerative gas turbine cycle, inter-cool gas turbine cycle, reheat gas turbine cycle, and intercool-reheat gas turbine cycle. The effect of pressure ratio of the topping cycle, the turbine inlet temperature of topping cycle, and ambient temperature on net power output, thermal efficiency, total exergy destruction, and exergetic efficiency of the combined cycle have been analyzed. The ratio of the net power output of the combined cycle to that of the topping cycle is maximal in the case when the topping cycle is a simple gas turbine cycle. The ratio of net power output and the total exergy destruction of the combined cycle to those of the topping cycle decrease with pressure ratio for all the combinations under study except for the case when the topping cycle is the regenerative gas turbine cycle.
Źródło:
Archive of Mechanical Engineering; 2022, LXIX, 3; 497--517
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Environmental and Energetical Possibilities of Sustainable Development of Wind and Photovoltaic Power Plants
Analiza ekologiczno-energetycznych możliwości zrównoważonego rozwoju elektrowni wiatrowych i fotowoltaicznych
Autorzy:
Piasecka, Izabela
Tomporowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/371833.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Komitet Człowiek i Środowisko PAN
Tematy:
renewable energy sources
sustainable development
wind power plant
photovoltaic power plant
life cycle assessment (LCA)
odnawialne źródła energii
rozwój zrównoważony
elektrownia wiatrowa
elektrownia fotowoltaiczna
środowiskowa ocena cyklu istnienia (LCA)
Opis:
The study evaluated the ecological and energetical possibilities of sustainable development of wind and photovoltaic power plants using the LCA method. An environmental analysis of the material phases of the life cycle of the 2 MW wind and photovoltaic power plant was conducted. The size of the environmental impacts over the life cycle and the scale of emissions of hazardous substances into the atmosphere, water and soil have been analyzed. Particular attention has been paid to greenhouse gas emissions and energy intensity levels recorded at various stages of the life cycle. The research conducted has provided the basis for formulating recommendations and guidelines for more pro-environmental, sustainable development of the analyzed renewable energy sources.
W artykule dokonano oceny ekologiczno-energetycznych możliwości zrównoważonego rozwoju elektrowni wiatrowych i fotowoltaicznych, z wykorzystaniem metody LCA. Przeprowadzono środowiskową analizę materialnych faz cyklu istnienia 2 MW elektrowni wiatrowej i fotowoltaicznej. Przeanalizowano wielkość następstw środowiskowych w ich całym cyklu życia oraz skalę emisji niebezpiecznych substancji do atmosfery, wody i gleby. Szczególną uwagę zwrócono na emisję gazów cieplarnianych oraz poziom energochłonności odnotowany w poszczególnych etapach cyklu istnienia. Przeprowadzone badania stały się podstawą do sformułowania zaleceń i wytycznych do bardziej prośrodowiskowego, zrównoważonego rozwoju analizowanych odnawialnych źródeł energii.
Źródło:
Problemy Ekorozwoju; 2018, 13, 2; 125-130
1895-6912
Pojawia się w:
Problemy Ekorozwoju
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienia ogólne dotyczące obciążenia środowiska w cyklu życia elektrowni wiatrowej
General issues in the environmental load in life cycle of power wind
Autorzy:
Matuszczak, K.
Flizikowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/95400.pdf
Data publikacji:
2015
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
elektrownia wiatrowa
cykl życia
obciążenia środowiska
odnawialne źródła energii
destrukcyjność
wind power
life cycle
environmental load
renewable energy sources
destructiveness
Opis:
Rozwój energetyki konwencjonalnej prowadzi do zmniejszania, a w konsekwencji zaniku zasobów nieodnawialnych (węgiel kamienny, ropa naftowa itd.). Niezbędna jest produkcja sztucznych, tanich, ekologicznych i odnawialnych dóbr energetycznych. Potencjał taki ma energia wiatru, która jest ogromnym stale odnawiającym się zasobem. Celem pracy była analiza i ocena użytecznych i szkodliwych obciążeń systemu oraz środowiska, generowanych w cyklu życia elektrowni wiatrowej. Przedstawiono powiązania pomiędzy oddziaływaniem obiektu na środowisko a rodzajem destrukcyjności, jakie wywołuje. Omówiono metodę LCA, która powiązana ze wskaźnikami użyteczności może być przydatna w ocenie i projektowaniu obciążeń środowiska w cyklu życia elektrowni wiatrowej.
The development of conventional energy leads to a reduction, and consequently loss of nonrenewable resources (coal, oil, etc.). It is necessary to manufacture artificial , cheap , clean and renewable energy goods . This potential has a wind, which is constantly renewing itself a huge resource. The aim of the study was to investigate , analyze and evaluate useful and harmful burden on the system and the environment, generated in the lifecycle of a wind power plant . It shows the relationship between the property's impact on the environment, and it produces a kind of destructiveness. Outlines a method for LCA , which related to the indicators of utility, may be useful in the evaluation and design the environmental load in the life cycle of a wind power plant.
Źródło:
Postępy w Inżynierii Mechanicznej; 2015, 6(3); 35-42
2300-3383
Pojawia się w:
Postępy w Inżynierii Mechanicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of optimisation methods applied to thermal cycle of a coal fired power plant
Autorzy:
Kowalczyk, Ł.
Elsner, W.
Powiązania:
https://bibliotekanauki.pl/articles/240829.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermodynamic optimisation
Nelder-Mead method
thermal cycle
coal fired power plant
IPSEpro
optymalizacja termodynamiczna
metoda Neldera-Meada
cykl termiczny
elektrownia węglowa
Opis:
The paper presents a thermodynamic optimization of 900 MW power unit for ultra-supercritical parameters, modified according to AD700 concept. The aim of the study was to verify two optimisation methods, i.e., the finding the minimum of a constrained nonlinear multivariable function (fmincon) and the Nelder-Mead method with their own constrain functions. The analysis was carried out using IPSEpro software combined with MAT-LAB, where gross power generation efficiency was chosen as the objective function. In comparison with the Nelder-Mead method it was shown that using fmincon function gives reasonable results and a significant reduction of computational time. Unfortunately, with the increased number of decision parameters, the benefit measured by the increase in efficiency is becoming smaller. An important drawback of fmincon method is also a lack of repeatability by using different starting points. The obtained results led to the conclusion, that the Nelder-Mead method is a better tool for optimisation of thermal cycles with a high degree of complexity like the coal-fired power unit.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 175-186
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Approach to Impact Assessment of the Rated Power Uprate of NPP Unit on the Service Life of the Turbine Critical Elements
Autorzy:
Chernousenko, Olga
Nikulenkova, Tetyana
Peshko, Vitaliy
Nikulenkov, Anatolii
Powiązania:
https://bibliotekanauki.pl/articles/1811575.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
nuclear power plant
reliability
turbine
steam flow
computational fluid dynamics
high pressure rotor
service life
long-term strength
low cycle fatigue
Opis:
Nuclear power plants play an important role in power systems of many countries. Ability to reasonable increase installed capacity of nuclear power units allow to reduce the cost for building of new power plants. When increasing NPP capacity to 104% there is a need to estimate the residual life of plant’s typical elements and continue their operation. The mathematical model of estimation of service life indicators of steam turbine K-1000-60/3000 is developed. The effect of increasing the capacity of a nuclear reactor on the heat transfer coefficients of a steam in the nozzle segments of high-pressure cylinder was established by using CFD modeling. The thermal and stress-strain state of the high-pressure rotor for the most typical operating modes are calculated. Using the correlation dependences of low-cycle fatigue, the rate of accumulation of cyclic damage of the base metal is established. The resistance of the metal to the exhaustion of long-term strength is also determined. On the example of the high pressure rotor of the 3rd power unit of Rivne NPP the service life indicators are calculated. The validity of increasing the installed capacity of the power unit was also confirmed.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 1; 105-116
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulating researches of power transmission system with torque converter in selected drive cycles
Badania symulacyjne układu napędowego z przekładnią hydrokinetyczną w wybranych cyklach jezdnych
Autorzy:
Woźniak, M.
Pawelski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/1365000.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz. Przemysłowy Instytut Motoryzacji
Tematy:
przekładnia hydrokinetyczna
sterownik silnika
test jezdny UITP
układ napędowy
drive cycle UITP
engine control unit (ECU)
power transmission system
torque converter
Opis:
In the paper it has been presented model of power train system for vehicle with diesel engine and automatic gearbox with hydraulic converter. Simulation model has been realised in MatLab Simulink R2009a programme. There has been presented its main subsystems and control system conception that have deciding influence on the driving system operation. In the proposed simulation model position of accelerating pedal is interpreted as the information according driver will of the assumed vehicle speed and way of its realisation (dynamic, economic drive), that is selection of the drive strategy. Existing ecological requirements it is the EURO 3,4,5 standards requires that proper strategies were realised ecologically. The decision of selecting the gear ratio and engine is undertaken in the master controller, beyond the driver, finally enabling the economic and ecological or dynamic operation of the total powertrain. In the final part of the paper there have been analysed results of simulation tests.
W pracy zaprezentowano model układu napędowego pojazdu z silnikiem o ZS i przekładnią automatyczną wyposażoną w przekładnię hydrokinetyczną. Model symulacyjny wykonany został przy użyciu programu MatLab Simulink R2009a. Przedstawiono jego główne podsystemy oraz koncepcję układu sterowania mające decydujący wpływ na prace układu napędowego. W zaproponowanym modelu symulacyjnym położenie pedału przyśpieszenia jest informacją o woli kierowcy, o zadanej prędkości pojazdu i sposobie jej osiągnięcia (jazda dynamiczna, ekonomiczna), czyli wyborze strategii jazdy. Obecne uwarunkowania ekologiczne tj. normy EURO 3,4,5, wymagają by odpowiadające im strategie jazdy były realizowane ekologiczne. Decyzja o wyborze przełożenia i stopniu obciążenia silnika jest podejmowana w sterowniku nadrzędnym, poza kierowcą, pozwalając ostatecznie na ekonomiczną, ekologiczną lub dynamiczną prace całego układu napędowego. W końcowej części pracy zostały poddane analizie wyniki badań symulacyjnych.
Źródło:
Archiwum Motoryzacji; 2011, 2; 97-108
1234-754X
2084-476X
Pojawia się w:
Archiwum Motoryzacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energetyka jądrowa – konieczność, a nie zagrożenie
Nuclear power – a necessity, not a threat
Autorzy:
Domański, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2176255.pdf
Data publikacji:
2022
Wydawca:
Mazowieckie Biuro Planowania Regionalnego w Warszawie
Tematy:
promieniowanie
rozpad promieniotwórczy
reaktor jądrowy
chłodziwo
moderator
moc cieplna
moc elektryczna
awaria
obieg parowy
paliwo jądrowe
sprawność
radiation
radioactive decay
nuclear reactor
coolant
thermal power
electrical power
failure
steam cycle
nuclear fuel
efficiency
Opis:
W pracy przedstawiono w skrócie potrzeby energetyczne świata, podział zużycia energii pierwotnej z punku widzenia paliw oraz 3 podstawowe scenariusze rozwoju świata prezentowane przez Międzynarodową Agencję Energii. Omówiono podstawowe procesy dotyczące wytwarzania energii jądrowej i jej konwersji na energię wewnętrzną. Przedstawiono najważniejsze typy reaktorów jądrowych podając ich podstawowe parametry pracy. W posumowaniu przedstawiono zasadnicze wnioski.
The work briefly outlines the world's energy needs, the division of primary energy consumption from a fuel perspective and the three basic world development scenarios presented by the International Energy Agency. The basic processes of nuclear power production and its conversion into internal energy are discussed. The most important types of nuclear reactors are presented with their basic operating parameters. The basic conclusions are presented in the summary.
Źródło:
MAZOWSZE Studia Regionalne; 2022, 42; 25-60
1689-4774
Pojawia się w:
MAZOWSZE Studia Regionalne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The new devices of gas-turbine engines of ground transport on the basis cascade pressure exchanger of krajniuk
Autorzy:
Krajniuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/374815.pdf
Data publikacji:
2011
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
kaskadowa wymiana ciśnienia
gazo-turbinowe silniki
cykl pracy
energooszczędność
wydajność
cascade pressure exchange
gas turbine engines
working cycle
power efficiency
performance
self-cooling
Opis:
Main trends of perfection of gas-turbine engines (GTE) of transport plants by application of principles of the cascade pressure exchange (CPE) for air compression in the working cycle of gas-turbine plant have been analyzed. The principle of action and performances of work of heat compressor CPE realizing compression of working body on the whole at the expense straight convert inputting heat in disposing work of torrent with insignificant distraction mechanics work from shaft selection of power has been described. The results of computational investigation of four variants of the GTE working process organization on the basis of the two-staged compression assembly with intermediate cooling and heating of air-gas medium have been adduced. Application of units CPE in the capacity of compressing stage GTE opens the prospect of adaptations GTE performance by conditions of work in the capacity of forcing units of overland transport.
Źródło:
Transport Problems; 2011, 6, 2; 107-119
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modele cyklu życia w ocenie destrukcyjności wirnika elektrowni wiatrowej. Cz. I. Podstawy teoretyczne
Application of life cycle models in the assessment of destructiveness of a wind power plant rotor. Part I. Theoretical bases
Autorzy:
Piasecka, I.
Powiązania:
https://bibliotekanauki.pl/articles/2071971.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektrownia wiatrowa
destrukcyjność
recykling
ocena cyklu życia (LCA)
Ekowskaźnik 99
CED
IPCC
wind power plant
destructiveness
recycling
life cycle assessment (LCA)
Eco-indicator 99
Opis:
W pracy dokonano przeglądu literatury odnoszącej się do oceny środowiskowej recyklingu zespołów roboczych elektrowni wiatrowej, opartej na modelowaniu LCA. Scharakteryzowano pojęcie destrukcyjności obiektów technicznych, omówiono główne założenia oceny cyklu życia (LCA) oraz przedstawiono wybrane modele oceny wpływu, a mianowicie Eko wskaźnik 99 {Eco-indicator 99), CED {Cumulative Energy Demand) oraz IPCC {IPCC 2007 GWP 100a (Intergovernmental Panel on Climate Change, Global Warming Potential, 100 years).
The paper presents a literature survey relating to the environmental assessment of recycling of wind power plant units, based on the LCA modeling. Destructiveness of technical objects is characterized, main assumptions of the life cycle assessment (LCA) are discussed and selected models assessing the impact, namely: Eco-indicator 99, CED (Cumulative Energy Demand) and IPCC (IPCC 2007 GWP 100a - Intergovernmental Panel on Climate Change, Global Warming Potential, 100 years) are presented.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 2; 103--104
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Possibilities of Increasing the Overall Efficiency of Gas-Steam CHP Microplant
Możliwości zwiększenia sprawności ogólnej kogeneracyjnej mikrosiłowni kombinowanej gazowo-parowej
Autorzy:
Piwowarski, M.
Kwaśniewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/952921.pdf
Data publikacji:
2018
Wydawca:
ENERGA
Tematy:
mikrosiłownia
obieg gazowo-parowy
czynnik niskowrzący
mikroturbina gazowa
mikroturbina parowa
micro power plant
gas-steam cycle
low-boiling point fluid
gas microturbine
steam microturbine
Opis:
The paper presents ways to increase the efficiency of a gas-steam micro power plant by modifying the cycle combination. The modification consists in partial release of the fluid downstream of the gas turbine and using it for ORC fluid overheating and evaporation. Advantages of this solution over the simplest gas and steam cycles’ combination are demonstrated.
W artykule przedstawiono sposoby zwiększenia sprawności mikrosiłowni gazowo-parowej poprzez modyfikację sposobu powiązania obiegów. Modyfikacja polega na zastosowaniu upustu części czynnika zza turbiny gazowej i wykorzystaniu go do przegrzania oraz odparowania czynnika ORC. Wykazano przewagę tego rozwiązania nad najprostszym sposobem powiązania obiegu gazowego z parowym.
Źródło:
Acta Energetica; 2018, 2; 81-86
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modele cyklu życia w ocenie destrukcyjności wirnika elektrowni wiatrowej. Cz. II. Wyniki badań
The use of life cycle models in the assessment of wind power plant rotor destructiveness. Part II. Research results
Autorzy:
Piasecka, I.
Tomporowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/2073044.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektrownia wiatrowa
destrukcyjność
recykling
ocena cyklu życia (LCA)
Ekowskaźnik 99
CED
IPCC
wind power plant
destructiveness
recycling
life cycle assessment (LCA)
Eco-indicator 99
Opis:
W pracy dokonano oceny środowiskowej opartej na modelowaniu LCA. Badania wykonano w odniesieniu do zespołu roboczego wirnika elektrowni wiatrowej Gamesa G90. Analizę cyklu życia przeprowadzono wykorzystując program SimaPro 7.1.8 (PRé Consultants). Oddziaływanie na środowisko określono za pomocą trzech metod oceny wpływu: Ekowskaźnika 99 (Eco-indicator 99 (E) V2.06/Europe El 99 E/A), CED (Cumulative Energy Demand V1.05) oraz IPCC (IPCC 2007 GWP 100a V1.01 - Intergovernmental Panel on Climate Change, Global Warming Potential, 100 yeras).
The environmental assessment based on LCA modeling is presented in the paper. The study was conducted in relation to the working unit of wind power plant rotor. Life cycle analysis was performed using SimaPro 7.1.8 (PRé Consultants) software. The environmental impact was determined using three methods of impact assessing: Eco-indicator 99 (E) (V2.06/Europe El 99 E/A), CED (Cumulative Energy Demand VI.05) and IPCC (IPCC 2007 GWP 100a V1.01 - Intergovernmental Panel on Climate Change, Global Warming Potential, 100 years).
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 6; 384--386
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal compressor of cascade exchange by pressure
Termiczny kompresor do kaskadowej wymiany ciśnienia
Autorzy:
Krajniuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/374103.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
kaskadowa wymiana ciśnienia
kompresor termiczny
cykl pracy
temperatura
energooszczędność
wydajność
charakterystyka obciążenia
cascade pressure exchange
thermal compressor
working cycle
temperature
power efficiency
performance
load characteristic
Opis:
A new method of organization of working cycle of device of direct transformation of heat in the located work of compression of air, based on principle of cascade exchange by pressure, is exposed; the results of pre-selection of basic dimensional and structural parameters of thermal compressor of cascade exchange by pressure are adduced; some special features of its working process are considered; main directions of perfection of working cycle of thermal compressors of cascade exchange of pressure are shown.
Źródło:
Transport Problems; 2010, 5, 1; 15-22
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza mocy i sprawności układu kogeneracyjnego turbiny gazowej i parowej
The Comparative Study on Selected Operation Parameters of a Combined Cycle Plant
Autorzy:
Chinhenha, A.
Mindykowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/947654.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Morski w Gdyni. Wydawnictwo Uniwersytetu Morskiego w Gdyni
Tematy:
obieg gazowo-parowy
moc elektryczna i sprawność całkowita obiegu
model analityczny
badania symulacyjne
analiza parametrów
combined cycle plant
electric power and total efficiency
analytical model
simulation research
parameters analysis
Opis:
Przedmiotem pracy są badania symulacyjne i analiza wybranych parametrów siłowni pracującej w obiegu gazowo-parowym. Celem pracy jest opracowanie metodyki oceny mocy i sprawności siłowni z turbinami pracującymi w obiegu gazowo-parowym z wykorzystaniem autorskiego modelu analitycznego rozważanej instalacji. Uzyskane na podstawie przyjętego modelu szacunkowe wartości mocy i sprawności siłowni porównano z wynikami uzyskanymi podczas testów odbiorczych przykładowej instalacji, przeprowadzonych przez jedno z wiodących konsorcjów, działających w obszarze systemów wytwarzania energii (SIEMENS AG. Power Generation Group).
This paper deals with analysis and simulation research of selected parameters of combined cycle plant. Presented work is focused on elaboration of the evaluation methodology of power and efficiency of combined cycle plant based on the author’s analytical model of considered installation. The estimated values of power and efficiency obtained on the basis of the elaborated model have been compared with the results obtained during the final tests of the exemplary installations carried out by the one of the leading producers of the systems in the power generation field.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Gdyni; 2018, 103; 26-42
1644-1818
2451-2486
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Gdyni
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie energii geotermalnej w mieście Buk
The use of geothermal energy in the city of Buk
Autorzy:
Zimny, Jacek
Struś, Mieczysław
Szymiczek, Jakub
Szczotka, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/27323741.pdf
Data publikacji:
2023
Wydawca:
STE GROUP
Tematy:
geotermia
elektrociepłownia geotermalna
ciepłownia geotermalna
ORC
Kalina
sprężarkowe pompy ciepła dużej mocy (SPCDM)
dublet geotermalny
geothermal energy
geothermal CHP plant
geothermal heat plant
organic Rankine cycle
high power compressor heat pumps
geothermal doublet
Opis:
Artykuł przedstawia projekt wykorzystania potencjalnych zasobów geotermalnych w mieście i gminie Buk. W pierwszych rozdziałach przedstawione są warunki geotermalne dla analizowanego regionu oraz potencjalne zbiorniki geotermalne umożliwiające efektywną eksploatacje wód termalnych. W mieście Buk są to zbiorniki jury dolnej, triasu dolnego oraz permu dolnego. Przedstawiona została głębokość technologia wykonania dwuotworowego systemu dubletu geotermalnego. W kolejnych rozdziałach przedstawione są technologie sprężarkowych pomp ciepła umożliwiające maksymalizację wykorzystania ciepła geotermalnego. Na zakończenie przedstawione są potencjalne moce cieplne uzyskane z odwiertu i potencjalny efekt ekologiczny.
The paper presents the potential use of geothermal resources in the town and municipality of Buk. The first chapters present the geothermal conditions for the analyzed region and the potential geothermal reservoirs for the efficient exploitation of thermal water. In the town of Buk, these are the Lower Jurassic, Lower Triassic and Lower Permian reservoirs. The technology of a two-hole geothermal doublet system is presented. In the following chapters, compressor heat pump technologies for maximizing the use of geothermal heat are presented. Finally, the potential heat capacities obtained from the borehole and the potential environmental effect are presented.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2023, 12, 1; 129-136
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opracowanie technologii dla wysoko sprawnych „zero-emisyjnych” bloków węglowych zintegrowanych z wychwytem CO2 ze spalin. Koncepcja i główne wyniki badań
Development of a technology for highly efficient “zero-emission” coal-fired units integrated with CO2 capture from flue gases. The concept and main findings
Autorzy:
Chmielniak, T.
Powiązania:
https://bibliotekanauki.pl/articles/282874.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
węglowy blok kondensacyjny nowej klasy
blok 50+
nowe metody diagnostyki
separacja CO2
integracja instalacji wychwytu dwutlenku węgla z obiegiem cieplnym
carbon block condensing
new class of coal power plant
Block 50+
new methods of diagnostics
CO2 separation
integration carbon dioxide capture plant with water – steam cycle
Opis:
Głównym zadaniem artykułu jest przekazanie informacji o koncepcji i wynikach badań uzyskanych w projekcie strategicznym Zaawansowane Technologie Pozyskiwania Energii, głównie w zadaniu 1: Opracowanie technologii dla wysokosprawnych „zero-emisyjnych” bloków węglowych zintegrowanych z wychwytem CO2 ze spalin. Jego głównym celem było: a) opracowanie metod, technologii i programów zwiększenia efektywności energetycznej i ekologicznej wytwarzania energii elektrycznej i ciepła w elektrowniach i elektrociepłowniach węglowych oraz podwyższenie ich niezawodności i dyspozycyjności, b) opracowanie dokumentacji technologicznej układów stanowiących podstawę do budowy krajowych instalacji demonstracyjnych wychwytu ze spalin oraz bezpiecznego składowania CO2, c) opracowanie dla warunków krajowych strategicznych kierunków rozwoju czystych technologii węglowych do zastosowań w energetyce, w tym bloków 50+. Przedstawiono koncepcję nowej klasy bloków kondensacyjnych na parametry pary: 650°C/670°C/30 MPa, które jednocześnie powinny spełniać wymagania capture ready. Wskazano na podstawie badań materiałowych i studiów konstrukcyjnych prowadzonych w projekcie na możliwość wzrostu temperatury pary pierwotnej do poziomu 673/670°C, a temperatury pary wtórnej do wartości 692/690°C, co stanowi istotny postęp w stosunku do obecnie budowanych bloków na parametry nadkrytyczne (para świeża/para wtórna 600 (610)/610 (620)°C). Analizowane kierunki wzrostu sprawności sprawdzano dla tej koncepcji bloku referencyjnego. Określono potencjał różnych przedsięwzięć służących poprawie sprawno- ści. Omówiono zakres badań w zakresie oceny elastyczności cieplnej, zwiększenia dyspozycyjności, nowych systemów diagnostycznych. Osobnym zagadnieniem rozpatrywanym w artykule jest analiza procesu wychwytu CO2 i dyskusja efektywności różnych opcji integracji instalacji wychwytu z obiegiem wodno-parowym bloku. W zakończeniu artykułu pokazano kierunki dalszych badań dla rozwiązania współczesnych problemów energetyki węglowej oraz wskazano na monografie dokumentujące wyniki uzyskane w projekcie.
The main task of this paper is to provide information about the concept and the results of the Strategic Research Programme entitled Advanced Technologies for Energy Generation, mainly in Task 1 – Development of a technology for highly efficient zero-emission coal-fired power units integrated with CO2 capture from flue gas. The main aim of this task was: a) to develop methods, technologies and programs in order to increase the efficiency of generating electricity at coal-fired power plants and increase their reliability and availability, b) to develop technological documentation of systems that will become a basis for the construction of national demonstration installations for the capture of CO2 from flue gases and its safe storage, c ) to work out Poland-specific directions for further development of clean coal technologies to be used in the power industry, including 50+ units. The concept of the new class of power plant units with steam parameters: 650°C/670°C/30MPa, which also will meet the “capture ready” requirements has been discussed. On the basis of material and structural studies carried out in the project the possibility of designing the unit with a leave steam temperature of 673/670°C, and the temperature of the steam reheat – 692/690°C has been show. This is a significant improvement over the currently built supercritical units (live steam / steam reheat 600 (610)/610(620)°C). The directions of efficiency increase was tested and analysed for a 900 MW unit. An efficiency improvement is found in all the cases under analysis. The range of tests for the assessment of thermal flexibility, increased availability and new diagnostic systems were also discussed. Another issue considered in the article was the analysis of the CO2 capture process and discussion of the effectiveness of different integration options for the separation unit with the water-steam cycle. The directions for further research for solutions of the contemporary problems of coal-based energy are presented and monographs documenting the results of the project are shown.
Źródło:
Polityka Energetyczna; 2015, 18, 3; 75-86
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-59 z 59

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies