Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pomiar zanieczyszczenia" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
AChE as biomarker of mussels and fish contamination with chemicals in the Gulf of Gdańsk
AChE jako biomarker skażenia chemikaliami małży i ryb z Zatoki Gdańskiej
Autorzy:
Kopecka, J.
Pempkowiak, J.
Powiązania:
https://bibliotekanauki.pl/articles/1826190.pdf
Data publikacji:
2004
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zanieczyszczenia środowiskowe
metale ciężkie
małże
pomiar biologicznych skutków zanieczyszczenia
biomarkery
Opis:
Significant part of the anthropogenic contaminants load reaching the marine environment enters the food chain. Traditionally, in order to monitor the effect of the contaminations on biota, analyses of the contaminants concentration in organisms have been carried out. Recently biomarkers were recognized as useful tool for assessment of the pollution impact on marine organisms. This is due to their sensitivity, low cost and specifity (Huggett et al, 1992; Walker and Livinstone, 1992; WHO, 1993). Levels of AChE activity are thought to be a useful indicator of biological responses in organisms (mussels and fish) to pollution. Inhibition of AChE activity in tissue has been proposed as a useful biomarker of an effective exposure to organophosphates and carbamates (Bocquene and Galgani, 1998; Schneider et al, 2000). Since the sources of contaminants are rather localised (mouth of the Vistula due to runoff, ports, sewage discharges) well-developed gradients of organic pollutants in organisms have been recorded. This is well documented and confirmed in this, biomarker oriented, study. This work was financially support from FP5 Program, Biological Effects of Environmental Pollution - BEEP.
W ciągu ostatnich kilkunastu lat udokumentowano w środowisku Morza Bałtyckiego spadek stężenia WWA, PCB, dioksyn i metali ciężkich. Jednak ze względu na wysoką toksyczność w odniesieniu do organizmów oraz ze względu na trwałość w środowisku morskim i akumulację w łańcuchu troficznym, należą one do najczęściej badanych zanieczyszczeń w programie środowiskowym. Jako metodę oceny stanu środowiska tradycyjnie stosuje się pomiar stężenia zanieczyszczeń w tkance miękkiej organizmów morskich. Jednak pomiar ten nie wiąże się bezpośrednio z oceną skutków ich akumulacji w organizmach żywych W ciągu ostatnich 15÷20 lat jako metodę toksykologii środowiskowej służącą do bardziej kompleksowej oceny stanu środowiska, wprowadzono pomiar biologicznych skutków zanieczyszczenia biocenozy - tzw. biomarkerów. Jako wskaźniki stosuje się tu zmiany w funkcjonowaniu organizmów na poziomie biochemicznym, fizjologicznym i histologicznym. Pozwalają one bezpośrednio określić wpływ zanieczyszczeń na organizmy żyjące w środowisku wodnym i mogą być one stosowane do pomiarów reakcji organizmów na chemiczne czynniki stresujące. Najwcześniej skutki biologiczne ujawniają się na poziomie komórkowym. Na poziomie organów i organizmów indywidualnych można zauważyć zmiany chorobowe, zaburzenia odporności i fizjologii. Śmierć organizmów, a tym samym spadek populacji, mniejsza bioróżnorodność, i w efekcie - degradacja środowiska przyrodniczego spowodowana jest długoterminowym efektem ekspozycji organizmów na zanieczyszczenia. Celem tej pracy było określenie poziomu Acetylocholinoesteracy (AChE) - enzymu współodpowiedzialnego za przekazywanie impulsów w systemie nerwowym w małżach i rybach z Zatoki Gdańskiej. Aktywność AChE ulega obniżeniu w organizmach eksponowanych na związki (np. pestycydy) fosforoorganiczne, i karbaminianowe. Organizmy pobierano z rejonów przybrzeżnych Zatoki Gdańskiej: Mechelinki, Sopot, ujście Wisły, z centralnej części Zatoki oraz punktu referencyjnego położonego na zewnątrz Półwyspu Helskiego. Badania wskaźników substancji szkodliwych objęły organizmy z dwóch gatunków małży (Macoma balthica i Mytilus trossulus) i jednego gatunku ryb - storni (Platichthys flesus). Analizie poddano wybrane tkanki (skrzela w M. trossulus, noga w M. balthica oraz mięśnie w storni) zostały zmierzone aktywności AChE (acetylocholinoesterazy). Analiza zbioru wyników aktywności (AChE) wykazała zmienność gatunkową stężenia AChE, różnice w AChE w organizmach męskich i żeńskich, i znaczną zmienność indywidualną. Nie stwierdzono statystycznie istotnych zmian w zmienności geograficznej i sezonowej. Natomiast w aktywności AChE w małżach nie obserwuje się istotnych różnic.
Źródło:
Rocznik Ochrona Środowiska; 2004, Tom 6; 99-106
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multirotor platform with sensory head for measurement of selected air parameters
Autorzy:
Jabłoński, K.
Czyba, R.
Grychowski, T.
Wiora, J.
Janik, M.
Łomnicka, N.
Galeja, M.
Powiązania:
https://bibliotekanauki.pl/articles/245005.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
unmanned aerial vehicle
pollution measurement
on-line air monitoring
environmental monitoring
embedded gas sensing system
bezzałogowy statek powietrzny
pomiar zanieczyszczenia
monitoring powietrza on-line
monitoring środowiska
wbudowany system wykrywania gazu
Opis:
In this article, a project of an unmanned aerial system designed for monitoring of air pollution is presented. The system consists of an autonomous unmanned aerial vehicle (UAV) equipped with a measurement head with sensors of chemical and physical properties of atmospheric air, and a ground control station arranged to store and display the collected data. The head contains modern sensors selective to the most important components of air in view of environmental pollution. Measurement data are acquired locally as well as transmitted wirelessly to a ground station. The UAV can be programmed to a particular measurement missions. The ground station dispose of a software for flight control and for visualisation of measurement results on-line. In this paper, an architecture of the entire system, a data processing performing by each subsystem, and communication methods between them are presented. This paper also includes a specification of sensors with their principles of operation, description of their metrological properties and the way, in which they are implemented in the designed electrical circuits. Results of preliminary tests in a laboratory and in a field, during a short flight, are also presented.
Źródło:
Journal of KONES; 2017, 24, 1; 179-187
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary zanieczyszczeń odorowych wieloczujnikowym urządzeniem z tlenkowymi czujnikami gazu
Measurement of odour pollutants with multisensor device with TGS gas sensor
Autorzy:
Sobczuk, H.
Guz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1819434.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
pomiar zanieczyszczeń
czujniki gazu
zanieczyszczenia odorowe
measurement of pollutants
gas sensors
odorous pollution
Opis:
Pomiary zapachowej jakości powietrza za pomocą urządzeń elektronicznych opartych na czujnikach gazów realizowane są już wielu gałęziach przemysłu. Stosuje się je w medycynie [1], w przemyśle spożywczym [6]. Znajdują też coraz szersze zastosowanie do monitoringu jakości powietrza w środowisku [10]. I tak np. zastosowane są na składowiskach odpadów, spalarniach, kompostowniach itp. [3÷5, 14]. Analiza zapachowa jest zadaniem wymagającym wcześniejszej kalibracji urządzeń i porównania ich wskazań z odczuciem zapachowym grupy osób testujących. Często stosowane czujniki TGS służą do detekcji zanieczyszczeń powietrza. Jest to możliwe dzięki zjawisku zmiany przewodnictwa elektrycznego półprzewodnikowego elementu pomiarowego w zależności od stężenia zanieczyszczenia, na które czujnik jest uczulony [8]. W czujnikach gazu TGS elementem pomiarowym jest elektroda wykonana z półprzewodnikowego dwutlenku cyny SnO2, wykazującego duże zmiany przewodnictwa pod wpływem redukujących zanieczyszczeń atmosfery. W zależności od przeznaczenia czujnika sensor zawiera różne domieszki, najczęściej metale szlachetne, powodujące jego uczulenie na specyficzny związek lub grupę związków chemicznych.
Measurement of odour quality of air with electronic devices is a task that requires calibration of the apparatus in advance. Calibration uses olfactory measurement results performed with the group of trained people. TGS sensors are often applied to detect the pollution of air with various pollutants. It is possible due to variation of electrical resistivity of the semiconducting sensor in response to the concentration of pollutants. Produced sensors are sensitized to specific pollutants but normally are not very specific. In a paper the measurement stand for measurement of odor pollutants concentration with multisensory device is presented and tested. Calibration measurements with the application of n-butanol is shown. Applied set of eight sensors allows to measure n-butanol samples with good accuracy. The setup allows measurements of both static, with a fixed concentration or dynamic by tracking changes in sensor response due to changes in odour pulse concentration change. Dynamic response of sensors makes it possible, in accordance with the literature, to measure with application of gas samples of a small volume. For the analysis of measurement results and comparison of different odours PCA method was used, which allows reduction of dimensionality of signal from multi-sensor devices.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1531-1542
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies