Wyszukujesz frazę "partial discharges" wg kryterium: Temat


Tytuł:
The impact of layout and concentration of defects on the electromechanical constraints in the MV cables insulation
Autorzy:
Medoukali, Hemza
Zegnini, Boubakeur
Powiązania:
https://bibliotekanauki.pl/articles/2203642.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
diagnosing
microcavities
density
electromechanical
XLPE
MV
FEM
partial discharges
diagnostyka
mikrowgłębienia
gęstość
wyładowanie niezupełne
metoda elementów skończonych
Opis:
The problem of the dense presence of voids in the solid insulation of cables remains a concern for researchers in terms of diagnosis and maintenance. The focus of this paper is to investigate the influence of both the layout and density of microcavities on the electrical and electromechanical constraints in the XLPE insulation of MV cables using numerical simulation. The simulation is based on the resolution of Laplace’s equation by the finite element method (FEM) using MATLAB. The electrostatic pressure and the elongation of the microcavities are estimated. This elongation leads to the formation of microchannels and then develops due to partial discharges to arborescence and in the end, the cable becomes out of service. This process takes a long time, so we use simulations to deepen the understanding of this phenomenon in a very short time. The electromechanical constraints are determined for different layouts and densities of microcavities.
Źródło:
Diagnostyka; 2023, 24, 2; art. no. 2023206
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of Partial Discharges in Cable Insulation and Cable Head Using Acoustic Method
Autorzy:
Ranachowski, Zbigniew
Wieczorek, Krzysztof
Ranachowski, Przemysław
Dębowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2141672.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
medium voltage insulation
acoustic emission
Opis:
The article presents the application of Acoustic Emission (AE) method for detection and registration of partial discharges (PD) generated in medium voltage (MV) cable isolation and MV cable head. The insulation of the high voltage cable is made of a flexible material whose properties are characterised by a high coefficient of attenuation of the acoustic signals. For this reason, the AE method has not been used so far to detect PD in energetic cables. The subjects of the research were the MV cable and the standard T-type cable head. The cable contained defects which were the source of partial discharges. In case of cable head the PD were provoked by thin grounded electrode which was introduced into connector opening. The results of AE measurements are presented in the form of spectrograms. Acoustic Emission was evoked when the applied voltage level reached the value of 7.5 kV for the cable and 4 kV for the cable head. The authors used the acoustic instrumentation of their own design intended for future field use. Obtaining successful results of partial discharges measurements using the acoustic method in the cable insulation makes an original contribution of the presented work.
Źródło:
Archives of Acoustics; 2022, 47, 2; 259-265
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charge dynamics of partial discharges explored applying a chopped sequence
Autorzy:
Florkowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/2086894.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
partial discharges
chopped sequence
high voltage insulation
non-invasive diagnostics
wyładowania niezupełne
sekwencja posiekana
izolacja wysokiego napięcia
diagnostyka nieinwazyjna
Opis:
Diagnostic methodologies are of fundamental importance for operational strategies of electrical devices, both in the power grid and in industrial applications. This paper reports about a novel approach based on partial discharge analysis applied to high voltage electrical insulation. Especially dynamics of charges deposited by partial discharges is explored applying a chopped sequence. The applications refer to microvoids occurring inside solid insulating systems or at the interfaces, such as delaminations at the electrodes. The experiments were carried out on embedded voids having distinctive wall dielectric materials. The underlying physical phenomena of post discharge charge transport are analyzed. The assessment is performed using phase-resolved partial discharge patterns acquired applying a chopped sequence. The chopped partial discharge (CPD) method provides quantitative insight into post discharge charge decay processes due to deposited and accumulated charges fluctuations. The assessment indicator is based on comparing partial discharge inception angle between chopped sequence and continuous run. The experiments have shown that materials with distinctive surface conductivity revealed adequately different charge decay time dynamics. The detailed analysis yields time constant of walls charge decay for insulating paper equal to 12 ms and cross-linked polyethylene 407 ms. The CPD method may be further used to investigate streamer physics inside bounded cavities in the form of voids. The presented method provides a quantitative approach for charge non-invasive decay assessment and offers high potential in future diagnostics applications.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 5; e138817, 1--8
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Application of Selected Hierarchical Clustering Methods for Classification the Acoustic Emission Signals Generated by Partial Discharges
Autorzy:
Borucki, Sebastian
Łuczak, Jacek
Lorenc, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2097707.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
power transformer
clustering method
Opis:
The paper presents the results of the application of the hierarchical clustering methods for the classification of the acoustic emission (AE) signals generated by eight basic forms of partial discharges (PD), which can occur in paper-oil insulation of power transformers. Based on the registered AE signals from the particular PD forms, using a frequency descriptor in the form of the power spectral density (PSD) of the signal, their representation in the form of the set of points on plane XY was created. Next, these sets were subjected to analysis using research algorithms consisting of selected clustering methods. Based on the suggested numeric performance indicators, the analysis of the degree of reproduction of the actual distribution of points showing the particular time waveforms of the AE signals from eight adopted PD forms (PD classes) in the obtained clusters was carried out. As a result of the analyses carried out, the clustering algorithms of the highest effectiveness in the identification of all eight PD classes, classified simultaneously, where indicated. Within the research carried out, an attempt to draw general conclusions as to the selection of the most effective hierarchical clustering method studied and the similarity function to be used for classification of the selected basic PD forms.
Źródło:
Archives of Acoustics; 2021, 46, 3; 409-417
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pilot implementation of the on-line partial discharge monitoring system for heads of the high voltage cable lines
Autorzy:
Konarski, Michał
Węgierek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/220896.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cable lines diagnostics
partial discharges
unconventional methods of partial discharges measurement
UHF electromagnetic method
Opis:
The article presents the assumptions, characteristics and description of the implementation of a pilot system for on-line monitoring of partial discharges in heads of the high-voltage cable lines. The main purpose of the implementation was to increase the reliability of cable line heads by equipping them with a system of continuous assessment of technical condition with direct transmission of measurement data and alarms to the SCADA system. In order to achieve the assumed goal, unconventional methods for measuring partial discharges were used, the application of which does not require disconnecting the line from the voltage. The implementation was carried out on an active 110 kV high voltage cable line in the area of activity of one of the Distribution System Operators.
Źródło:
Metrology and Measurement Systems; 2020, 27, 2; 373-382
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt badawczo-rozwojowy SORAL – system oceny stanu technicznego i ryzyka awarii linii kablowych SN oparty o badania diagnostyczne wykonywane w trybie off line
SORAL - system for condition monitoring and failure risk assessment of MV cable lines based off line diagnostic methods
Autorzy:
Noske, Sławomir
Zasada-Chruścińska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/267590.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
pomiary diagnostyczne kabli
pomiary wyładowań niezupełnych
pomiary tangensa delta
Health Index
Diagnostic measurements of cables
partial discharges
tangent delta measurements
health Index
Opis:
Sieć kablowa średniego napięcia (SN) stanowi istotny element sieci dystrybucyjnej. Dotychczasowe zarządzanie tą częścią sieci jest głównie oparte na analizach awaryjności, tzn. wzrost liczby awarii na danej linii świadczy o pogarszającym się stanie technicznym. Jest to system mało efektywny, wiąże się z dodatkowymi kosztami usuwania awarii, przerwami w dostawie energii, utrudnionym planowaniem inwestycji i prac eksploatacyjnych. Planowane, w ramach projektu SORAL, prace badawczo-rozwojowe mają doprowadzić do wdrożenia zarządzania siecią kablową SN opartego na wymiernej ocenie stanu technicznego poszczególnych elementów linii. Podstawą prac jest wykorzystanie pomiarów diagnostycznych. Analizy rynku i doświadczenia Energa Operator SA z pracy w międzynarodowych stowarzyszeniach wskazują, że projekt ma charakter innowacyjny na poziomie światowym.
The article describes the current experience in applying the diagnostics of MV cable lines in the DSO and the ongoing SORAL project. Diagnostic systems which measure partial discharges and tan delta in MV lines have been used in Poland since the turn of the century. Research work so far has focused on MV cables and on attempts to define key parameters which would indicate advanced ageing processes. The measurements and analyses conducted so far have not enabled the formulation of assessment criteria for failure risk. However, key parameters indicating the increase in the failure risk have been identified. The research up to now is a valuable contribution to the process of creating assessment criteria for failure risk, using the IT system which automates this process. This task is carried out now in the SORAL project. The project is implemented by DSO (ENERGA-OPERATOR) and IT Company (Globema) consortium and is financed from EU funds.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 63; 23-26
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High voltage harmonics induced modifications of PD phase-resolved patterns
Autorzy:
Florkowski, M.
Florkowska, B.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/141372.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrical insulation system
diagnostics
harmonics
partial discharges
phase-resolved patterns
Opis:
Partial discharges (PD) are influencing electrical insulating systems of high voltage electrical devices. Typically, in laboratory and diagnostics AC tests focused on measuring and analysis of PD, a pure sinusoidal voltage waveform is assumed. However, in practice the spectral content of the working voltage is rarely so ideal and additional spectral components have a significant impact on the discharge behaviour in electrical insulation systems. In this paper the influence of voltage harmonics on PD behaviour and phase-resolved PD patterns evolution is analysed. The presented experiments were conducted on a specimen representing a gaseous inclusion embedded in electrical insulation. The experimental results showed that various harmonic compositions superimposed on the fundamental sinusoidal waveform have a significant impact on PD intensity and maximum charge. In consequence, the derived patterns of PD phase, and magnitude distributions are distorted, and statistical parameters calculated on their basis are changed. In certain environments, neglecting harmonic content in the testing voltage may lead to a misleading interpretation and assessment of PD severity.
Źródło:
Archives of Electrical Engineering; 2018, 67, 2; 231--246
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Clustering Methods for the Identification of Acoustic Emission Signals Generated by the Selected Form of Partial Discharge in Oil-Paper Insulation
Autorzy:
Borucki, S.
Łuczak, J.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/177657.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission method
acoustic signals
partial discharges
insulation
power transformer
Opis:
The article presents the results concerning the use of clustering methods to identify signals of acoustic emission (AE) generated by partial discharge (PD) in oil-paper insulation. The conducted testing featured qualitative analysis of the following clustering methods: single linkage, complete linkage, average linkage, centroid linkage and Ward linkage. The purpose of the analysis was to search the tested series of AE signal measurements, deriving from three various PD forms, for elements of grouping (clusters), which are most similar to one another and maximally different than in other groups in terms of a specific feature or adopted criteria. Then, the conducted clustering was used as a basis for attempting to assess the effectiveness of identification of particular PD forms that modelled exemplary defects of the power transformer’s oil-paper insulation system. The relevant analyses and simulations were conducted using the Matlab estimation environment and the clustering procedures available in it. The conducted tests featured analyses of the results of the series of measurements of acoustic emissions generated by the basic PD forms, which were obtained in laboratory conditions using spark gap systems that modelled the defects of the power transformer’s oil-paper insulation.
Źródło:
Archives of Acoustics; 2018, 43, 2; 207-215
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
Autorzy:
Mišák, S.
Hamacek, Š.
Bartłomiejczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/221694.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fault trees
partial discharges
fault diagnosis
power engineering
power overhead lines
Opis:
This paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the above mentioned faults was developed. After having tested its operation, the system has already been implemented to protect mediumvoltage overhead lines built of covered conductors.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 277-288
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyładowania niezupełne w wybranych układach modelowych oraz analiza numeryczna warunków polowych ich powstawania
Partial discharges in selected model insulating systems and numerical analysis of field conditions for their inception
Autorzy:
Zydroń, P.
Roehrich, J.
Mikrut, P.
Bonk, M.
Powiązania:
https://bibliotekanauki.pl/articles/267153.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne
modelowe układy izolacyjne
pole elektryczne
obrazy fazowo-rozdzielcze wnz
partial discharges
model insulating systems
electric field
PD phase-resolved patterns
Opis:
Wyładowania niezupełne (wnz) powstające w układach izolacyjnych urządzeń wysokonapięciowych mogą przybierać różne formy, zależne od właściwości fizykochemicznych zastosowanych materiałów dielektrycznych, wzajemnej konfiguracji geometrycznej izolacji i układu elektrod oraz rodzaju i geometrii defektu. W artykule przedstawiono wyniki rejestracji i analiz zbiorów impulsów wyładowań niezupełnych powstających w trzech różnych, modelowych układach izolacyjnych (wyładowania ulotowe, wyładowania w zamkniętej inkluzji gazowej zlokalizowanej wewnątrz układu izolacyjnego oraz wyładowania powierzchniowe, powstające w obecności punktu potrójnego metalgazdielektryk). Analiza wyładowań dotyczyła specyficznych cech ich obrazów fazowo-rozdzielczych D(, q, n). Biorąc pod uwagę fakt, że pole elektryczne jest podstawową przyczyną powstawania wyładowań niezupełnych w wysokonapięciowych układach izolacyjnych zaprezentowano różnice w rozkładach natężenia pola elektrycznego w badanych układach modelowych.
Partial discharges (PD) occurring in insulation systems of high-voltage equipment can take various forms, depending on: the physicochemical properties of used dielectric materials; the geometric configuration of the insulating system and the electrode arrangement; and also the type and geometry of the defect. The paper presents the results of registration and analysis of partial discharge pulses sets generated in three different models of insulating systems (corona discharges; discharge in closed gas inclusions located inside the insulating system, and surface discharge formed in the presence of triple point metal-solid dielectric-gas). The analysis of the discharges concerned the specific features of their phase-resolved patterns D(, q, n). The differences in distribution of electric field intensity in the studied insulating systems were also presented, due to the fact that this is the primary cause of partial discharges in high-voltage insulating systems.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 165-170
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie szyków antenowych w lokalizacji źródeł wyładowań niezupełnych
Application of antenna arrays in the location of partial discharge sources
Autorzy:
Roehrich, J.
Szafraniak, B.
Zydroń, P.
Powiązania:
https://bibliotekanauki.pl/articles/267219.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne
systemy lokalizacyjne
szyki antenowe
metody TOA/TDOA
partial discharges
locating system
antenna arrays
TOA/TDOA methods
Opis:
Wyładowania niezupełne (wnz) są źródłami impulsowych zaburzeń elektromagnetycznych o bardzo szerokim widmie. Dzięki temu dla ich wykrywania i lokalizowania mogą być stosowane metody antenowe, wykorzystujące różne techniki pomiarowe. W szczególności dotyczy to lokalizowania wyładowań powstających w liniach napowietrznych i urządzeniach stacji elektroenergetycznych wysokich i najwyższych napięć. W artykule przedstawiono podstawy i rozważania teoretyczne dotyczące zastosowania w tym celu szyków (macierzy) antenowych o różnych konfiguracjach oraz wybrane wyniki badań laboratoryjnych. Przedstawione zostały m.in. analizy zastosowania metody TDOA (Time Difference Of Arrival), pozwalającej na określenie położenia źródeł wyładowań niezupełnych w oparciu o pomiar różnic czasów detekcji przebiegów impulsowych rejestrowanych przez poszczególne anteny wchodzące w skład szyku antenowego.
Partial discharges (PD) are sources of very short impulsive electromagnetic disturbances with extra wide spectrum. As a result, aerial methods using various measuring techniques can be used to detect and locate them. In particular, this refers to locating partial discharges occurring at overhead transmission lines and power station equipment of high and very high voltages. The paper, which presents the continuation of the work of authors in this field, describes theoretical foundations and theoretical considerations as well as the results of laboratory investigations of the use of antenna arrays of various configurations for PDs source location. The analysis of the application of the TDOA method (Time Difference of Arrival) to determine the position of the discharge sources is based on the measurement of the time differences of pulse waveforms received by the individual antennas – members of particular antenna array.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 103-108
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości detekcji wyładowań niezupełnych w aparaturze rozdzielczej średnich napięć w izolacji powietrznej metodą przejściowego napięcia doziemnego
Analysis and detection possibility of the partial discharges in air insulated medium voltage switchgear using transient earth voltage detection
Autorzy:
Buczko, R.
Sikora, A.
Powiązania:
https://bibliotekanauki.pl/articles/408523.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
wyładowania niezupełne
aparatura rozdzielcza
przejściowe napięcie doziemne
partial discharges
switchgear
transient earth voltage
Opis:
W nowoczesnej aparaturze rozdzielczej wykorzystuje się w coraz większym stopniu materiały polimerowe jako układy izolacyjne. Mimo swoich licznych zalet, wykazują one niekiedy ograniczoną wytrzymałość na wyładowania niezupełne. W artykule przedstawiono analizę możliwości wykorzystania nieinwazyjnej metody przejściowego napięcia doziemnego TEV do detekcji różnych form wyładowań niezupełnych w aparaturze rozdzielczej średnich napięć. Dzięki wykorzystaniu tej metody, diagnostyka odbywa się bez konieczności odstawiania urządzenia od systemu elektroenergetycznego. Uzyskane wyniki potwierdzają skuteczność metody.
Modern switchgear increasingly use polymeric materials as insulation. Despite its numerous advantages they have limited resistance to partial discharge corrosion in some cases. In this paper noninvasive methods Transient Erath Voltage (TEV) measurement is proposed to detect various forms of partial discharges in medium voltage switchgear. These method allows for non-invasive diagnostic without switch of the switchgear. Measurement results confirm the effectiveness of the proposed approach.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 3; 70-74
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kierunkowe układy detekcji VHF/UHF dla lokalizacji źródeł wyładowań niezupełnych w liniach napowietrznych i urządzeniach stacji elektroenergetycznych
Directional VHF/UHF detection systems for the location of partial discharge sources in overhead lines and substations equipment
Autorzy:
Roehrich, J.
Zydroń, P.
Szafraniak, B.
Kwaśny, D.
Szeląg, D.
Powiązania:
https://bibliotekanauki.pl/articles/952812.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
wyładowania niezupełne
systemy lokalizacyjne
detekcja VHF/UHF
anteny kierunkowe
partial discharges
locating system
VHF/UHF detection
directional antennas
Opis:
Współczesne wymagania dotyczące niezawodności dostaw energii elektrycznej rodzą konieczność prowadzenia badań diagnostycznych i monitorowania poprawności działania pracujących urządzeń elektroenergetycznych. Występujące defekty linii napowietrznych oraz urządzeń stacji elektroenergetycznych, charakteryzujące się podwyższeniem wartości lokalnego natężenia pola elektrycznego ponad wartość krytyczną powodują powstawanie wyładowań niezupełnych, w różnych ich formach. Pozwala to stosować, w celu wykrywania i lokalizowania defektów, metody antenowe, z detekcją szerokopasmową w zakresach VHF/UHF. W artykule dokonano przeglądu zastosowań układów szerokopasmowej detekcji antenowej w diagnostyce urządzeń elektroenergetycznych. Przedstawiono wyniki badań laboratoryjnych wybranych układów detekcji kierunkowej, służących wykrywaniu różnych form wyładowań elektrycznych w powietrzu poprzez detekcję impulsowych zaburzeń elektromagnetycznych.
Contemporary requirements for a reliable supply of electricity generate the need for diagnostics and monitoring of proper operation of working electrical power equipment. Defects occurring in transmission lines and substations devices, characterized by the increase of the local electric field strength above the critical value, cause the formation of partial discharges (PD), in their various forms. In order to detect and locate defects it is possible to use wideband antenna methods for PD pulses detection in the VHF/UHF range. The article reviews the applications of wideband antenna detection systems in the diagnosis of the electrical power devices. The results of laboratory tests of selected directional detection systems applied for location of various forms of electrical discharges in the air, by detecting pulsed electromagnetic disturbances, are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie propagacji impulsów wyładowań niezupełnych w uzwojeniach transformatorów energetycznych z zastosowaniem stanowiska laboratoryjnego
Modelling partial discharge pulses propagation in the windings of power transformers using laboratory stand
Autorzy:
Zydroń, P.
Bonk, M.
Fuśnik, Ł.
Bęc, K.
Maniak, D.
Szafrański, F.
Powiązania:
https://bibliotekanauki.pl/articles/267389.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
uzwojenia transformatora
wyładowania niezupełne
lokalizacja
modelowanie numeryczne
transformer windings
partial discharges
localization
numerical modelling
Opis:
Transformatory energetyczne są jednymi z podstawowych elementów systemu elektroenergetycznego. Objawem wewnętrznych defektów ich układu izolacyjnego może być powstawanie wyładowań niezupełnych (wnz). Sygnały elektryczne wywołane przez wnz są rejestrowane na doprowadzeniach liniowych, do których docierają propagując wzdłuż uzwojeń, od miejsca ich występowania. W zależności od położenia defektu oraz jednostkowych parametrów elektrycznych uzwojenia zmieniają się parametry czasowo-częstotliwościowe sygnałów obserwowanych w miejscu ich detekcji. W artykule przedstawiono wyniki badań propagacji impulsów wnz na modelu laboratoryjnym uzwojenia transformatora oraz, dla porównania, wyniki symulacji numerycznych w programie Matlab/Simulink. Podczas symulacji stosowano pewne uproszczenia złożonej struktury uzwojenia transformatora analizując wpływ miejsca wyładowania na wybrane właściwości impulsów rejestrowanych na zacisku liniowym.
Power transformers are one of the basic elements of the power system. The occurrence of partial discharge is a symptom of internal defects of their insulating system. Electrical signals caused by partial discharges are recorded on the line terminals that receive electrical signals propagating along the winding from the source of discharge. Depending on the location of the defect and the characteristic parameters of the electrical windings are changing parameters of the timefrequency signals observed in the place of its detection. The article presents the results of the propagation of pulses PD in models of transformer windings, compared to the results of numerical simulations. During the simulation takes into account the complex, multi-element structure of the windings of the transformer and its impact on the time-frequency characteristics of pulses recorded on a terminal line.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 51; 221-224
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototyping of UHF antennas using simulation software
Autorzy:
Polak, F.
Sikorski, W.
Siodła, K.
Powiązania:
https://bibliotekanauki.pl/articles/97315.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
partial discharges
UHF antenna
antenna design
simulations
Opis:
The method of ultra high frequency is being increasingly applied in the power transformer diagnostics. Using the probe (antenna) mounted inside the transformer tank it is possible to detect partial discharges occurring in defects of high–voltage insulation system. Such probes must be designed and optimized on several factors, such as frequency band, directivity, or the geometrical design etc. This paper presents parameters of two types of antennas (discone and microstrip patch) obtained through simulation. Calculations and simulations results will provide basis to comnstruct the prototypes of the antennas, which will eventually find application in the measurement system used for localisation of partial discharges inside power transformers.
Źródło:
Computer Applications in Electrical Engineering; 2016, 14; 168-176
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies