Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "palec" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Kinematic analysis of the finger exoskeleton using MATLAB/Simulink
Autorzy:
Nasiłowski, K.
Awrejcewicz, J.
Lewandowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/307115.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kinematyka
egzoszkielet
palec
MATLAB
Simulink
kinematic
finger
exoskeleton
Opis:
A paralyzed and not fully functional part of human body can be supported by the properly designed exoskeleton system with motoric abilities. It can help in rehabilitation, or movement of a disabled/paralyzed limb. Both suitably selected geometry and specialized software are studied applying the MATLAB environment. A finger exoskeleton was the base for MATLAB/Simulink model. Specialized software, such as MATLAB/Simulink give us an opportunity to optimize calculation reaching precise results, which help in next steps of design process. The calculations carried out yield information regarding movement relation between three functionally connected actuators and showed distance and velocity changes during the whole simulation time.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 3; 129-134
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating biomechanical function of toes through external manipulation integrating analysis
Autorzy:
Mei, Q.
Fernandes, J.
Hume, P.
Gu, Y.
Powiązania:
https://bibliotekanauki.pl/articles/306943.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
palec nogi
uchwyt
przyczepność
uszkodzenia
toes
grip
windlass mechanism
metatarsal injury
Opis:
Purpose: This study was aimed to investigate the function of toes while running through comparing bound toes by external-manipulation with natural separate toes by evaluating kinematics and plantar pressure analysis. Methods: Seven habitually barefoot male runners participated in the running test under toes binding and non-binding conditions, and Vicon and Novel insole plantar pressure measurement were conducted synchronously to collect kinematics and foot loading. Results: Ankle kinematics showed larger non-significant range of motion in the frontal plane while running with toes non-binding.The medial forefoot had a smaller force time integral, and with hallux had a larger force time integral than those of running with toes binding, with significance level p < 0.05. Conclusions: While no significance existed between bound and non-bound toes in kinematics, the medial forefoot had a smaller foot impulse and the hallux had a larger foot impulse for those with non-binding feet. This suggests that other functions such as the active gripping action of toes might be important for the efficiency of the foot windlass mechanism (the plantar fascia support), which would be beneficial for running performance improvement and foot injury prevention.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 97-102
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analytical expression for the D.I.P.–P.I.P. flexion interdependence in human fingers
Autorzy:
Van-Zwieten, K. J.
Schmidt, K. P.
Bex, G. J.
Lippens, P. L.
Duyvendak, W.
Powiązania:
https://bibliotekanauki.pl/articles/306688.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
model
palec
kinematyka
koordynacja
finger
kinematical
interphalangeal
flexion
coordination
Opis:
Empirical evidence shows that a strong correlation exists between the flexion angles of the distal and proximal interphalangeal (D.I.P., P.I.P.) joints of the human finger. Several authors measured this functional dependence, stating that the interdependence of D.I.P. and P.I.P. flexion is different for healthy individuals and patients displaying pathologies. The purpose of our study is to find an analytical expression for this correlation. Methods: Following closely the anatomical in situ relations, we developed a two-dimensional kinematical model which expresses analytically the D.I.P.–P.I.P. angle correlation. Numerical values for the model were extracted from one healthy and one pathological case data set. Results: The analytical form of the model allows for any P.I.P. angle not only to calculate the corresponding D.I.P. angle, but after first order differentiation with respect to the P.I.P. angle, it also shows the rate of change of the D.I.P. flexion. The model reproduces well the differences in the angular correlation of D.I.P. flexion of the two healthy-pathological data sets. Displaying the rate of change of D.I.P. flexion versus P.I.P. flexion provides an additional, clear-cut discriminatory tool between normal and pathological states. Conclusions: Information on differences between normal and pathological flexion of fingers is more pronounced and easier accessible from the derivatives of the D.I.P.–P.I.P. flexion behaviour than from direct angular correlation data. The analytical form of our model allows one to establish the rate of change of the D.I.P. angles, resulting in a better analysis of the situations at hand.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 1; 129-135
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differences in gait pattern between the elderly and the young during level walking under low illumination
Autorzy:
Choi, J.-S.
Kang, D.-W.
Shin, Y.-H.
Tack, G.-R.
Powiązania:
https://bibliotekanauki.pl/articles/307026.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
gait
illumination
elderly
stance ratio
toe clearance
safety margin
chód
iluminacja
wiek
palec nogi
Opis:
The purpose of this study was to compare changes in the gait pattern between the elderly and young during level (i.e., even surface) walking under low illumination. Vision during walking plays a role in avoiding obstacles and uneven surfaces, as well as an important role in the proactive control of dynamic stability and route planning for level walking. Fourteen elderly and fourteen young male subjects walked on a 7 m walkway with two illumination conditions using self-selected walking speed: walking with normal (>300 lux) and low illumination (<10 lux). Walking speed, stance phase ratio, toe clearance on swing phase, and range of motion at the center of mass were used to compare the differences in gait pattern between two illumination conditions and ages. During walking with low illumination, walking speed and stance phase ratio of the young decreased, and toe clearance of the young increased. However, there was no difference in these variables due to low illumination in the elderly subjects. Despite level walking conditions, there were some differences in gait pattern between the young and the elderly due to illumination conditions. This implies that the young showed a more positive change of gait pattern, due to low illumination, than that of the elderly. In this respect, further study is necessary to identify differences between the young and the elderly, when they walk on an uneven or obstacle walkway with low illumination.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 1; 3-9
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gdy bogiem było Słońce - starożytne jednostki miar (cz. I)
When the god was the Sun - the ancient measure units
Autorzy:
Wollek, A.
Powiązania:
https://bibliotekanauki.pl/articles/154945.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
starożytne miary
łokieć
dłoń stopa
piędź
palec
ancient measure units
cubit
palm
feet
span
finger
Opis:
W artykule autor zabiera czytelnika w wędrówkę po świecie antyku przedstawiając wybrane jednostki miar używanych przez największe cywilizacje świata starożytnego: Sumer, Egipt, Grecję i Rzym. Artykuł podzielono na dwie części. W pierwszej opisano prawdopodobnie pierwszy przykład wykorzystania do pomiarów skali naturalnej, którym były tokeny. Kolejne rozdziały zawierają opisy jednostek miar długości, odległości i pola powierzchni. W drugiej części artykułu autor przedstawił jednostki miar masy, objętości oraz związane z nimi aspekty prawne i religijne.
In his paper the Author is taking readers to the journey through the ancient world. He describes old units of measure used by the most famous ancient civilizations of the world such as: Sumer, Egypt, Greece and Rome. The paper is divided into two parts. The first one contains 7 chapters (including references), the second one 6. The first part includes information about tokens, the length, the distance and the area measure units. Tokens are small forms made from the clay. They were used for counting from about 8,000 B.C. to 1500 B.C in Mesopotamia. This is the first known usage of the natural scale to the measure. The length units were the first defined units of the measure (approximately 3,000 B.C.). In Sumer and Egypt the basic unit of the length was a cubit, in Greece and Rome it was a foot. The Sumerian cubit was divided into the 30 fingers, the Egyptian into the 28 (the royal cubit) or into the 24 (the small cubit). The foot was divided to the 16 fingers. The area measure were an agricultural or a life frequently dependent. The information about weight and volume units are in the second part of the paper including. The Sumerian weight measure units were taken by another civilizations like: Acadians, Babylonians, Assyrians and Greeks. The most kinds have the volume units. Another one was for liquids and another one for dry measure. The one of the lasts chapters describes the law conditions refer to the measure units. Some samples, including Urnammu legal code and the Bible, are available.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 9, 9; 787-789
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multisensors for whole-cell analytics
Multisensory dla biosensorów pełnokomórkowych
Autorzy:
Tobehn-Steinhäuser, I.
Günther, M.
Görlandt, S.
Herbs, S.
Wünscher, H.
Ortlepp, T.
Gerlach, G.
Powiązania:
https://bibliotekanauki.pl/articles/408794.pdf
Data publikacji:
2018
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
Diclofenac
impedance spectroscopy
transparent ITO-electrode
switchable electrical interdigital finger
multiplexer
spektroskopia impedancyjna
przezroczysta elektroda ITO
przełączany palec elektrodowy
multiplekser
Opis:
Whole-cell biosensors, which can be used in the environmental protection and process measuring technology, in the biotechnology, food and pharmaceutical industry for the on-line control and monitoring of chemical and biochemical processes and for the fast detection of small amounts of solutes, are of great interest. These kind of biosensors comprise microorganisms like genetically modified yeast cells, which react on a specific stimulus, e.g. a residual amount of drugs in the measurement medium with a dependent fluorescence. The receptors of the cells detect specific signal molecules and stimulate the organism to produce a fluorescent protein. In this work, a combined impedimetric-optical read out was used, which can provide the reliable and long-term stable detection of a fluorescence signal accompanied by impedance measurements monitoring cell vitality and activity. A new challenge thereby is a special sensor design which enables the integration of excitation source, photodetector, interdigitated electrodes, and the fluidic system with an effective and long-term-stable packaging.
Biosensory pełnokomórkowe cieszą się bardzo dużym zainteresowaniem. Mogą one być wykorzystywane w ochronie środowiska i technologii pomiaru procesów, w branży biotechnologicznej, spożywczej i farmaceutycznej do kontrolowania i monitorowania procesów chemicznych i biochemicznych on-line oraz do szybkiego wykrywania niewielkich ilości substancji rozpuszczonych,. Tego rodzaju biosensory obejmują mikroorganizmy, takie jak genetycznie zmodyfikowane komórki drożdży, które reagują na specyficzny bodziec, np. fluorescencją na resztkowa ilość leków w pożywce pomiarowej. Receptory komórek wykrywają określone cząsteczki sygnałowe i stymulują organizm do wytwarzania białka fluorescencyjnego. W pracy wykorzystano łączony odczyt impedancyjno-optyczny, który może zapewnić niezawodną i długotrwale stabilną detekcję sygnału fluorescencyjnego, któremu towarzyszą pomiary impedancji monitorujące żywotność i aktywność komórek. Nowym wyzwaniem jest specjalna konstrukcja czujnika, która umożliwia integrację źródła pobudzenia, fotodetektora, elektrod palcowych i układu płynowego w jednej obudowie.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2018, 8, 2; 39-41
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies