Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "oxygen excess" wg kryterium: Temat


Tytuł:
Influence of the exhaust gas recirculation on the oxygen contents and its excess ratio in the engine combustion chamber
Autorzy:
Postrzednik, S.
Żmudka, Z.
Przybyła, G.
Powiązania:
https://bibliotekanauki.pl/articles/245080.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
exhaust gas recirculation (EGR)
oxygen content
stoichiometric conditions
oxygen excess
Opis:
Exhaust gas recirculation (EGR) can be realized on the external or internal way. The main goal of EGR is to decrease the combustion temperature of the combustible mixture by increasing the relative heat capacity of the working medium. An additional effect is to reduce the oxygen content in the gas mixture flowing into the combustion chamber. To quantify the exhaust gas recirculation some descriptive parameters are defined, including: – exhaust gas recirculation rate R, – multiple of exhaust gas recirculation K, – relative exhaust gas recirculation W. The analysis concerns the effective oxygen excess ratio Oef in the combustible mixture and the so-called internal oxygen excess ratio Ow,, which additionally takes into account the supplied oxygen with the recirculation stream. It was found that with increasing of the exhaust gas recirculation degree systematically decreases the content of the oxygen [O2]d in the combustible mixture, while increases the oxygen excess ratio Oef observed in the exhaust gases. Changes of this all parameters influence the combustion coditions in the engine cylinder, and next the achieved specifaic work, energy efficiency and emission of the combustion engine. An advanced system with independent, early exhaust valve closing enables realization of an internal EGR. Effectiveness of internal recirculation is lower than the external recirculation.
Źródło:
Journal of KONES; 2013, 20, 3; 315-321
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Properties of Copper Doped Neodymium Nickelate Oxide as Cathode Material for Solid Oxide Fuel Cells
Autorzy:
Lee, K. J.
Choe, Y-J.
Hwang, H-J.
Powiązania:
https://bibliotekanauki.pl/articles/351292.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solid oxide fuel cells
copper
electrical conductivity
excess oxygen
Opis:
Mixed ionic and electronic conducting K2NiF4-type oxide, Nd2Ni1-xCuxO4+δ (x=0~1) powders were synthesized by solid state reaction technique and solid oxide fuel cells consisting of a Nd2Ni1-xCuxO4+δ cathode, a Ni-YSZ anode and ScSZ as an electrolyte were fabricated. The effect of copper substitution for nickel on the electrical and electrochemical properties was examined. Small amount of copper doping (x=0.2) resulted in the increased electrical conductivity and decreased polarization resistance. It appears that this phenomenon was associated with the high mean valence of nickel and copper and the resulting excess oxygen (δ). It was found that power densities of the cell with the Nd2Ni1-xCuxO4+δ (x=0.1 and 0.2) cathode were higher than that of the cell with theNd2NiO4+δ cathode.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2A; 625-628
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intermittent Resistance Exercise: Evolution from the Steady State
Autorzy:
Scott, Christopher B.
Powiązania:
https://bibliotekanauki.pl/articles/1055179.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Szczeciński. Wydawnictwo Naukowe Uniwersytetu Szczecińskiego
Tematy:
anaerobic energy
blood lactate
excess post-exercise oxygen consumption (EPOC)
Opis:
Oxygen uptake measurements are without question useful and a staple measurement for the estimation of exercise energy costs. However, steady state models cannot be used to successfully model intermittent resistance exercise energy costs. Our laboratory has taken steps to avoid such comparisons between these discrepant exercises. We have separated out exercise and recovery periods during resistance training and utilize capacity (kJ) estimates as opposed to rate measures (kJ min-1). Moreover, we avoid anaerobic threshold concepts as applied to resistance exercise. When viewed accordingly, resistance exercise energy costs are opposite those of the steady state model: exercise oxygen uptake is highest for steady state exercise and lowest for resistance exercise, recovery oxygen uptake can be the highest energy cost for resistance exercise whereas for steady state exercise it may or may not be meaningful, and anaerobic energy costs represent a significant component of resistance exercise that plays little to no role with steady state exercise.
Źródło:
Central European Journal of Sport Sciences and Medicine; 2014, 6, 2; 85-91
2300-9705
2353-2807
Pojawia się w:
Central European Journal of Sport Sciences and Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of ultrasonic field strength on the structural changes of disintegrated excess sludge
Wpływ natężenia pola UD na zmiany struktury dezintegrowanych osadów nadmiernych
Autorzy:
Barański, M.
Zawieja, I.
Wolny, L.
Powiązania:
https://bibliotekanauki.pl/articles/395741.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
osad nadmierny
stabilizacja beztlenowa
struktura osadów
excess sludge
sludge structure
physical conditioning
chemical oxygen demand (COD)
anaerobic stabilization
Opis:
Exposure of sludge to the ultrasonic field as a disintegrating factor before the mesophilic anaerobic stabilisation directly affects the increase in the susceptibility of sludge on the biochemical process of decomposition in the anaerobic conditions. Thanks to the use of sewage sludge pretreatment, an increase of the disintegration degree of sludge undergoing physical modifications is reached, as well as the intensification of biogas production. The aim of the study was to record changes in the structure of excess sludge tested, as well as the determination of disintegration degree [%] versus the strength of ultrasound wave [W/cm2]. An ultrasonic disintegrator VCX – 1500 (Sonics Company) was used in the investigation. The test substrate was excess sludge from the Central Wastewater Treatment Plant P.S.W. "WARTA" in Czestochowa. Two cycles of tests were conducted, which implement the following amplitude A= 7.85 [mikro]m and 39.25 [mikro]m and the time of sonification ts = 30 ÷ 360s. The most beneficial effect of ultrasound treatment on the excess sludge was noted for the amplitude A=39.25 [mikro]m and the sonication time 360s, which resulted in 83.25% degree of disintegration of excess sludge. For these parameters, the strenght of ultrasonic wave was 4.8 W/cm2. In addition, a large dispersion of sludge particles prepared with ultrasonic field and enlargement of the liquid phase in relation to unconditioned sludge were observed. The noted changes of structure correlate with the obtained degree of disintegration of the excess sludge.
Poddanie osadów działaniu pola ultradźwiękowego, jako czynnika dezitegrującego przed procesem mezofilowej stabilizacji beztlenowej wpływa bezpośrednio na zwiększenie podatności osadów na proces biochemicznego rozkładu w warunkach beztlenowych warunkując szybkość przebiegu fazy hydrolitycznej fermentacji metanowej. Dzięki zastosowaniu prekondycjonowania osadów ściekowych uzyskuje się wzrost stopnia przefermentowania osadów poddanych fizycznej modyfikacji, jak również intensyfikację produkcji biogazu. Celem prowadzonych badań przy użyciu dezintegratora ultradźwiękowego o mocy 1500W z automatycznym strojeniem typu VCX–1500 amerykańskiej firmy SONICS było zobrazowanie zmian zachodzących w strukturze osadów nadmiernych, jak również określenie wartości stopnia dezintegracji [%] od natężenia fali ultradźwiękowej [W/cm2]. Substratem badań był nadmierny osad czynny pochodzący z Centralnej Oczyszczalni Ścieków P.S.W. „WARTA” w Częstochowie. Przeprowadzono dwa cykle badawcze, w których zastosowano następujące amplitudy drgań A = 7,85 žm i 39,25 žm oraz czas nadźwiękawiania tn = 30 ÷ 360s. Najkorzy-stniejszy wpływ działania czynnego pola ultradźwiękowego na osady ściekowe odnotowano dla amplitudy A.39,25 žm oraz czasu sonifikacji 360s, dla których uzyskano 83,25% stopień dezintegracji osadów nadmiernych. Natężenie fali UD dla omawianych parametrów pola ultradźwiękowego wynosiło 4,8 W/cm2. Ponadto zaobserwowano znaczną dyspersję cząstek osadów preparowanych polem UD oraz powiększenie fazy ciekłej w odniesieniu do osadów niekondycjonowanych. Zmiany struktury korelowały z uzyskanym stopniem dezintegracji osadów nadmiernych.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 117-126
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stechiometryczne uwarunkowania oraz skutki realizacji recyrkulacji spalin
Stoichiometric conditions and effects of the exhaust gas recirculation
Autorzy:
Postrzednik, S.
Żmudka, Z.
Przybyła, G.
Powiązania:
https://bibliotekanauki.pl/articles/134065.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
silnik spalinowy
recyrkulacja spalin
stosunek tlenu
uwarunkowania stechiometryczne
combustion engine
exhaust gas recirculation (EGR)
oxygen content
excess
stoichiometric conditions
Opis:
Zasadniczym celem stosowania recyrkulacji spalin jest obniżenie temperatury spalania mieszanki palnej, poprzez wzrost względnej pojemności cieplnej czynnika roboczego. Do ilościowego ujęcia recyrkulacji wykorzystano pojęcia: stopień R, krotność K recyrkulacji spalin oraz jej wartość względna W. Analiza dotyczy stechiometrycznych skutków recyrkulacji: udziału tlenu [O2]d w mieszaninie gazów dopływających do komory spalania, efektywnego λ ef stosunku nadmiaru tlenu oraz tzw. wewnętrznego stosunku nadmiaru tlenu λw, w którym uwzględnia się tlen dostarczany ze strumieniem recyrkulujących spalin. Dzięki przeprowadzonej analizie uwarunkowań i skutków recyrkulacji okazało się, ze wzrostem stopnia recyrkulacji systematycznie zmniejsza się udział [O2]d tlenu w mieszance palnej, a jednocześnie obserwuje się wzrost wewnętrznego stosunku nadmiaru tlenu λ w. Ustalone współzależności wpływają istotnie na parametry (ciśnienie p, temperaturę T) obiegu silnika, pozyskiwaną pracę mechaniczną oraz sprawność energetyczną, a także na emisję substancji szkodliwych.
The main goal of EGR is to decrease the combustion temperature of the combustible mixture by increasing the relative heat capacity of the working medium. An additional effect is to reduce the oxygen content in the gas mixture flowing into the combustion chamber. The analysis concerns the effective oxygen excess ratio λ ef in the combustible mixture and the so-called internal oxygen excess ratio λw, which additionally takes into account the supplied oxygen with the recirculation stream. It was found that with increasing of the exhaust gas recirculation degree systematically decreases the content of the oxygen [O2]d in the combustible mixture, while increases the oxygen excess ratio λ ef observed in the exhaust gases. Changes of this all parameters influence the achieved specifaic work, energy efficiency and emission of the combustion engine.
Źródło:
Combustion Engines; 2013, 52, 3; 379-382
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of Thermal and Alkaline Disintegration of Excess Sludge on Biodegradation
Autorzy:
Zawieja, Iwona
Powiązania:
https://bibliotekanauki.pl/articles/952398.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
volatile fatty acids
excess sludge
thermal disintegration
alkaline disintegration
soluble chemical oxygen demand
SCOD
total organic carbon
TOC
VFAs
methane fermentation
Opis:
Thermal methods of sludge disintegration can be divided into high temperature (over 100°C) and low temperature (below this temperature). They consist in the supply or removal of thermal energy, contributing to the changes in sludge structure and physicochemical properties. During the chemical disintegration of excess sludge with sodium hydroxide, there is an increase in the pH value, as well as changes in their structure. The OH- ions are highly toxic to the microorganisms living in the excess sludge and affect the decline of biological activity of most microorganisms. The aim of the conducted research was to prove the impact of the thermal and alkaline disintegration of excess sludge on the susceptibility of organic substances to biodegradation. The thermal disintegration of excess sludge was carried out in a shaking water bath, in which the sludge placed in laboratory flasks with an active volume of 0.5 L were heated for a specified period within the scope of the so-called low temperatures, i.e. 65–95 °C. The sludge was heated for a period of 0.5–12 h. The alkaline disintegration of the sludge was carried out with sodium hydroxide in the form of dust at ambient temperature, in sealed plastic bottles with an active volume of 5L, the contents of which were mixed manually every few hours. The regent doses in the range of 0.05–1.3 g NaOH/g VSS and disintegration time 12h were used. As a result of subjecting the excess sludge to disintegration by means of the selected methods, an increase in the concentration of organic substances in the dissolved form in the supernatant liquid was noted. On the basis of the increase in SCOD, TOC value and VFAs concentration, the most favorable modification conditions were determined. As a result of disintegration of the sludge and subsequent methane fermentation, the supporting effects of the applied modification methods were observed, in relation to the conventional methane fermentation of excess sludge.
Źródło:
Journal of Ecological Engineering; 2019, 20, 10; 172-182
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie spalania biopaliwa, oleju opałowego i gazu propan - przy różnych ciśnieniach podawanego paliwa
Comparison of combustion of oil, biofuel and LPG in a heat furnace - at different pressure of fuel
Autorzy:
Zdrojewski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/286576.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tlenek azotu
tlenek węgla
temperatura spalin
współczynnik nadmiaru powietrza
nitric oxide
carbon monoxide
oxygen
coefficient of excess air
exhaust temperature
chimney losses
Opis:
Do jednego pieca o mocy 71-85 kW i pojemności 96 litrów, instalowano palnik na olej opałowy lub biopaliwo oraz palnik na gaz propan. Ustalając stałą ilość podawanego powietrza, zmieniano ciśnienie podawanego paliwa w zakresie 8-11 hPa dla gazu i 14-25 MPa dla olejów. Stwierdzono, że ilość tlenków azotu NOx była dla obu olejów podobna (55-77 mg/m3, w zależności od współczynnika nadmiaru powietrza), natomiast dla propanu była o ok. 25 mg/m3 większa. Zawartość tlenku węgla CO dla olejów i mniejszych ciśnień propanu była śladowa, natomiast dla większych ciśnień gazu rosła do 3000 ppm. Strata kominowa zmniejszała się z 7,5 do 7% dla biodiesla, z 8,2 do 5,9% dla oleju opałowego i z 6,8 do 5,5% dla gazu. Temperatury spalin na wylocie z pieca wynosiły dla gazu 133-147 0C, dla biopaliwa 142-169 0C i dla oleju opałowego 146-164 0C.
Oil, biofuel and liquid gas propan were burned in the heat furnace of thermal power 71-85 kW, using 2 burners (oil or gas). Pressure was regulated for gas from 8 to 11 hPa and for oil from 14 to 25 MPa. Amount of carbon monoxide was very small for oil and bio fuel. For gas was the same but only for low pressure. For high er pressure, amount of CO increased up to 3000 ppm. Amount of nitric oxide was the same for oil and biodiesel ( from 55 to 77 mg/m3 ) and for gas was higher about 25 mg/m3. Chimney losses for LPG were the lower, 6%, and for biodiesel 0,5% higher than for fuel oil, 7%. When the pressure increased, himney losses for biodiesel changed only a little (from 7,5 to 7%), but for oil were higher (from 8,2 to 5,9%) and for gas were the smallest (6,8 to 5,5%).Temperatures of exhaust for biodiesel and oil were quite the same (142-169°C and 146-164°C respectively), but for gas propan were the lowest (133-147°C).
Źródło:
Inżynieria Rolnicza; 2006, R. 10, nr 4(79), 4(79); 357-366
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Errors Associated With Excess Air Multipoint Measurement Systems
Autorzy:
Ramsunkar, C.
Tonder, C. von
Schmitz, W.
Powiązania:
https://bibliotekanauki.pl/articles/184927.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
excess air measurement
flue gas oxygen concentration
boiler O2
air ingress
nadmiar pomiaru powietrza
stężenie tlenu spaliny
kocioł O2
wnikanie powietrza
Opis:
Boiler combustion air is generally controlled by the excess air content measured at the boiler economiser outlet using oxygen (O2) analysers. Due to duct geometry and dimensions, areas of high and low O2 concentrations in the flue gas duct occur, which poses a problem in obtaining a representative measurement of O2 in the flue gas stream. Multipoint systems as opposed to single point systems are more favourable to achieve representative readings. However, ash blockages and air leakages influence the accuracy of O2 measurement. The design of multipoint system varies across ESKOMs’ Power Stations. This research was aimed at evaluating the accuracy of the multipoint oxygen measurement system installed at Power Station A and to determine the systematic errors associated with different multipoint systems designs installed at Power Stations' A and B. Using flow simulation software, FloEFDTM and Flownex®, studies were conducted on two types of multipoint system designs This study established that significantly large errors, as high as 50%, were noted between the actual and measured flue gas O2. The design of the multipoint system extraction pipes also introduces sigdnificant errors, as high as 23%, in the O2 measured. The results indicated that the sampling errors intro- introduced with Lethabo's system can be significantly reduced by adopting the sampling pipe design installed at Camden.
Źródło:
Chemical and Process Engineering; 2015, 36, 4; 405--423
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ termicznej hydrolizy na zmiany struktury osadów nadmiernych poddanych stabilizacji beztlenowej
Influence or thermal hydrolysis on the excess sludge structure during anaerobic stabilization
Autorzy:
Barański, M.
Zawieja, I.
Powiązania:
https://bibliotekanauki.pl/articles/297785.pdf
Data publikacji:
2010
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
osad nadmierny
struktura osadów
chemiczne zapotrzebowanie tlenu
ChZT
kondycjonowanie termiczne
stabilizacja beztlenowa
excess sludge
sludge structure
chemical oxygen demand
COD
thermal pretreatment
anaerobic stabilization
Opis:
Zastosowanie termicznej obróbki osadów przed procesem mezofilowej stabilizacji beztlenowej wpływa na zwiększenie podatności osadów na proces biochemicznego rozkładu w warunkach beztlenowych. W wyniku kondycjonowania osadów uzyskano wyższy stopień dezintegracji osadów poddanych działaniu podwyższonej temperatury w odniesieniu do stopnia dyspersji surowych osadów nadmiernych. W wodzie nadosadowej modyfikowanych termicznie osadów zaobserwowano wzrost wartości stężenia substancji organicznych w formie rozpuszczonej wyrażony przyrostem wartości chemicznego zapotrzebowania tlenu (ChZT) oraz lotnych kwasów tłuszczowych (LKT). Celem przeprowadzonych badań, mających charakter obserwacji mikroskopowych, było zobrazowanie oraz ocena zmian zachodzących w strukturze osadów nadmiernych podczas termicznej modyfikacji osadów oraz w kolejnych 10 dobach procesu stabilizacji beztlenowej. Substratem badań był nadmierny osad czynny pochodzący z Centralnej Oczyszczalni Ścieków P.S.W. "WARTA" w Częstochowie. W celu zainicjowania procesu stabilizacji osad nadmierny zaszczepiono osadem przefermentowanym, stanowiącym 10% mieszaniny badawczej. Badania przeprowadzono dla Mieszaniny I (osad nadmierny + osad przefermentowany) oraz Mieszaniny II (osad nadmierny kondycjonowany termicznie w temp. 70°C przez 1,5 h + osad przefermentowany).
Application of sludge thermal treatment before the mesophilic anaerobic stabilization process influenced on the increase of sludge susceptibility to biochemical decomposition in anaerobic conditions. In the result of thermal pretreatment the higher disintegration degree of sludge submitted to temperature action, in comparison to dispersion degree of raw excess sludge was observed. In the liquid phase of the sludge pretreated by the mentioned method, the increasing of concentration value of organic substances in soluble form was noticed. It was expressed by the increase of chemical oxygen demand (COD) value. The purpose of the microscope observation study was the estimation of the sludge structure changes during thermal modification as well as during successive days of 10 days' anaerobic stabilization process. The subject of the tests was excess active sludge coming from the waste water treatment plant P.S.W. "WARTA" in Czestochowa. The tests were conducted on a mixture of excessive and digested sewage that was subjected to mesophilic methane fermentation. The Mixture I (raw excess sludge + digested sludge) and the Mixture II (thermal pretreatment excess sludge at the temp 70°C through the period of 1.5 h + digested sludge) were submitted to the research.
Źródło:
Inżynieria i Ochrona Środowiska; 2010, 13, 2; 85-91
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność generowania lotnych kwasów tłuszczowych podczas mezofilowej i termofilowej fermentacji metanowej osadów nadmiernych
Efficiency of generating volatile fatty acids during mesophilic and thermophilic anaerobic digestion of excess sludge
Autorzy:
Zawieja, I.
Wolny, L.
Próba, M.
Powiązania:
https://bibliotekanauki.pl/articles/401516.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
osady nadmierne
termofilowa fermentacja metanowa
termiczna dezintegracja
lotne kwasy tłuszczowe
chemiczne zapotrzebowanie na tlen
excess sludge
thermophilic anaerobic digestion
thermal disintegration
volatile fatty acids
chemical oxygen demand
Opis:
Aktywność mikroorganizmów warunkujących szybkość przemian zachodzących podczas procesu fermentacji metanowej zależy od warunków środowiskowych procesu. Czynnikiem intensyfikującym przebieg fermentacji metanowej jest wzrost temperatury procesu. Prowadzenie procesu fermentacji metanowej w warunkach termofilowych wpływa na szybkości reakcji zachodzących podczas fazy hydrolizy, przyczyniając się do zwiększenia stężenia lotnych kwasów tłuszczowych generowanych z osadów, a w efekcie zwiększenia produkcji biogazu. Należy jednak podkreślić, iż bakterie termofilne wykazują dużą wrażliwość na zmiany temperatury już rzędu ± 0,5°C/d, przy optimum ich wzrostu w zakresie 52–55°C. W związku z tym, aby proces przebiegał optymalnie, bez zakłóceń, konieczne jest zapewnienie stabilnych warunków środowiskowych prowadzących do maksymalnej redukcji substancji organicznych. Podstawowym substratem badań, charakteryzującym się wysoką zawartością związków organicznych i związków azotowych, były osady nadmierne. W celu określenia wpływu fermentacji termofilowej na generowanie lotnych kwasów tłuszczowych osady ściekowe poddano 8-dobowej stabilizacji beztlenowej. Wykonano następujące oznaczenia fizyczno-chemiczne: sucha masa, pH, zasadowość, lotne kwasy tłuszczowe, chemiczne zapotrzebowanie na tlen. W kolejnych dobach procesu, w odniesieniu do fermentacji prowadzonej w warunkach mezofilowych, odnotowano wzrost generowania lotnych kwasów tłuszczowych oraz korelujący z nim wzrost wartości chemicznego zapotrzebowania na tlen. W 8 dobie procesu prowadzonego w warunkach termofilowych stężenie lotnych kwasów tłuszczowych wynosiło 1749 mgCH3COOH/dm3, natomiast wartość chemicznego zapotrzebowania na tlen 3279 mgO2/dm3, przy zasadowości rzędu 3800 mgCaCO3/dm3.
Microbial activity determining the speed of the changes occurring during the process of anaerobic digestion depends on the environmental conditions of the process. The factor intensifying the process of methane fermentation is an increase of temperature. The conducting of the methane fermentation in thermophilic conditions affect the rate of the reactions taking place during the phase of hydrolysis, thus contributing to increase the concentration of volatile fatty acids generated from the sludge, resulting in increasing the production of biogas. It should be noted, however, that thermophilic bacteria have a high sensitivity to temperature changes already the order of ± 0.5 °C/d at their optimum growth in the range of 52–55 °C. Therefore, for the process would run optimally smoothly unnecessary to ensure stable environmental conditions leading to maximum reduction of organic substances. The basic test substrate, characterized by a high content of organic and nitrogen compounds, is excess sludge. To determine the effect of generating the volatile fatty acids during the thermophilic fermentation the sludge was submitted 8-daily anaerobic stabilization. The following designations of physico-chemical characteristics were made: dry matter, pH, alkalinity, volatile fatty acids, the chemical oxygen demand. In the following days of the process operation with regard to fermentation carried out under mesophilic conditions the increase of volatile fatty acids generation was observed, which also correlated with the increase of the chemical oxygen demand. In the 8th day of thermophilic conditions the concentration of volatile fatty acids was 1749 mgCH3COOH/dm3, while the chemical oxygen demand 3279 mgO2/ dm3 and the alkalinity row of 3800 mgCaCO3/dm3.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 226-232
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies