Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "osteosynthesis" wg kryterium: Temat


Tytuł:
Osteosynthesis on the basis of resorbable polymers implants - selected problems
Autorzy:
Będziński, R.
Chłopek, J.
Frątczak, R.
Kotela, I.
Powiązania:
https://bibliotekanauki.pl/articles/285918.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynthesis
resorbable polymers
biomaterials
Opis:
Use of bioresorbable materials in bone surgery opens up new possibilities in treatment of injuries and orthopaedic illnesses. Lack of necessity for implant removal surgery enables faster treatment and substantial reduction in costs of treatment. In recent years, these advantages have caused growing interest in materials of this type. It must be noted that bioresorbable materials in most cases are based on macromolecular materials – polymers which have completely different mechanical characteristics than traditional materials used in bone surgery. Bioresorbable properties give enormous possibilities but also present difficult challenges related to construction of new types of implants based on materials of this type. Full characteristics of new materials is indispensable in construction process, especially of mechanical properties and surface properties. The latter is responsible for contact with biological environment and bioactivity is determined on the basis of hydroxyapatite precipitations amount on material surface. In case of polymer based composites, influence of phases in powder and fibre form on properties is fundamental to be proved. Addition of particle modifier into polymer matrix causes reduction in strength of polymer. This phenomenon is mostly associated with homogenic particle distribution difficult to be achieved in case of higher filler content. However biological interplay is insufficient by low filler contents. Therefore in the below presented investigations different filler contents were applied and their influence on mechanical properties was investigated to achieve compromise between mechanical properties and bioactive, antibacterial or anti-inflammatory effect of the applied particles. Acquaintance with these results allowed for elaboration of full range of material and constructive solutions for implants in bone surgery. Biodegradable biopolymers have low mechanical properties (Young’s modulus, strength, viscoelasticity). Construction process of bioresorbable implants requires to be completely changed in way of conduction. Computer simulation based investigations of stress-strain characteristics is necessary to be carried out in each stage of research. Bigger cross-sections and different shapes of implants are required to achieve suitable stiffness. Application of bone screws made of resorbable materials requires design of these elements from the bottom up. Design of optimal shape of screw thread and point of contact between screw head and bone plate is particularly important. 9 different implants were designed within the confines of conducted research – including for tibia, humerus, radius, ulna, phalanges, clavicle, calcaneus, pelvis and metatarsus. Stress values were determined in analyzed implants. Acceptable loads were determined for individual types of plate. Plates made of PLA can bear small loads and play role mainly as grasping and holding bone element. In most cases additional immobilization of operated bone is required in order to prevent plate or screw destruction. In case of stabilization function for resorbable materials – as many screws as possible are recommended – thanks to it, screws are less loaded and the plate-bone system is more immobilized.
Źródło:
Engineering of Biomaterials; 2014, 17, no. 128-129; 108
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania przyczyn uszkodzeń minipłytek tytanowych stosowanych w chirurgii szczękowo-twarzowej
The study of fractures in titanium miniplates used in reconstructive jaw and face surgery
Autorzy:
Bieniaś, J.
Surowska, B.
Świeć, P.
Pałysewicz, B.
Maślanko, G.
Tomaszewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/284868.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomateriały
tytan
osteosynteza
minipłytki
chirurgia szczękowa
biomaterials
titanium
osteosynthesis
miniplates
maxillofacial surgery
Opis:
W pracy przedstawiono analizę materiałową mini-płytek tytanowych wykorzystywanych przy zabiegach osteosyntezy kości twarzoczaszki w aspekcie zmian struktury i warstwy wierzchniej materiału (określenie przyczyn i rodzaju zużycia). Materiał badawczy stanowiły minipłytki tytanowe 2, 6, 10- oczkowe oraz 2, 4-oczkowe z przerwą, stosowane przy zabiegach osteosyntezy kości, które: (a) usunięto po zakończeniu leczenia lub (b) usunięto wcześniej z powodu uszkodzenia (pęknięcia). Badane płytki wykonane były z czystego technicznie tytanu-grade 2. Przeprowadzona analiza materiałowa wskazuje na kilka możliwych czynników wpływających na uszkodzenia - złamania minipłytek, do których można zaliczyć: stan warstwy wierzchniej z licznymi defektami stanowiącymi miejsca propagacji i rozwoju pęknięć, stan naprężeń twarzoczaszki, możliwość występowania procesów zmęczeniowych oraz zmiany w mikrostrukturze minipłytek tytanowych spowodowane odkształcaniem mechanicznym.
The study presents the material analysis of miniplates used during the osteosynthesis of the face from the aspect of structural and surface layer change of material (establishment of reasons and type of wear). The material analysed were 2, 6, 10- hole and 2, 4-hole (with interval) titanium miniplates used in bone osteosynthesis, which: (a) were removed once the treatment has been completed or (b) were removed before the completion of the treatment because of a damage (fractures). The plates were made of commercially pure titanium-grade 2. The analysis indicates a few possible factors causing the damages - fractures of the miniplates, which include: the condition of the surface layer with visible defects, which are the centres of propagation and the development of fractures, the condition of facial stress, the possibility of fatigue processes as well as the changes in the microstructure of titanium miniplates caused by mechanical deformation.
Źródło:
Engineering of Biomaterials; 2008, 11, 74; 2-5
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka mechaniczna wielofunkcyjnej resorbowalnej płytki kompozytowej do zespoleń kostnych
Mechanical characterization of multifunctional resorbable composite plate for osteosynthesis
Autorzy:
Gryń, K.
Szaraniec, B.
Morawska-Chochół, A.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/284036.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynteza
zespolenie kostne
płytki zespalające
płytki kompozytowe
płytki wielofunkcyjne
polimer resorbowalny
polilaktyd
hydroksyapatyt
fosforan wapnia
własności mechaniczne
parametry wytrzymałościowe
osteosynthesis
bone plate
composite plates
multifunctional plates
resorbable plates
poly-lactide
hydroxyapatite
tricalcium phosphate
mechanical characterisation
durability
Opis:
W artykule przedstawiono badania mechaniczne prototypowego wszczepu do zespoleń kostnych w postaci resorbowalnej wielofunkcyjnej czterootworowej płytki w kształcie litery I. Testy dotyczyły gotowych implantów w symulowanych warunkach pracy, a nie normatywnych próbek (wiosło, belka) dlatego przygotowano odpowiedni modelowy schemat badawczy implantu. Składał się on z dwóch bloczków imitujących odłamy kostne, połączonych za pomocą badanej płytki, który był poddawany testom mechanicznym w izolowanych stanach naprężeniowo-odkształceniowych (jednoosiowe rozciąganie, trójpunktowe i jednostronne zginanie). Badano płytki wykonane z dwóch odmian polimeru resorbowalnego (poli-L-laktydu) oraz dwa rodzaje kompozytu, w których osnowę stanowiła jedna z odmian polimeru, a fazą modyfikującą była mieszanina mikrometrycznego proszku ortofosforanu trójwapnia i nanometrycznego hydroksyapatytu. Badano także wpływ geometrii płytek na charakterystyki mechaniczne. Na podstawie przeprowadzonych badań stwierdzono wyraźny wpływ dodatków ceramicznych na zmianę parametrów wytrzymałościowych płytek wykonanych z różnych materiałów. W przypadku polilaktydu z dopuszczeniem medycznym zaobserwowano spadek wytrzymałości przy jednoczesnym podniesieniu modułu Younga E. Ponadto geometria implantu, czyli w badanym przypadku lokalizacja żeberka wzmacniającego, wpływała na uzyskane wyniki. Lepszymi parametrami cechowały się płytki z żeberkiem wzmacniającym na górnej stronie płytki. Ponadto podczas testów zginania stwierdzono, że przy tego rodzaju geometrii płytki pęknięcie lokalizuje się poza przekrojem krytycznym, a więc taka konstrukcja jest bardziej bezpieczna. Z grupy przebadanych prototypów, jako najlepsze, wybrano płytki kompozytowe PL38/TCP/HAp, wykonane z poli-L-laktydu medycznego, modyfikowanego mieszaniną proszków ceramicznych z żeberkiem wzmacniającym na powierzchni górnej. Mogą one znaleźć zastosowanie w osteosyntezie, w miejscach które nie są narażone na zbyt duże obciążenia mechaniczne. Do tej grupy zaliczyć można kości w obrębie twarzoczaszki oraz kości krótkie ręki. Zaleca się przy tym zastosowanie usztywniających opatrunków zewnętrznych.
The article presents the mechanical properties of prototype multifunctional four-hole, I-shaped plate made of resorbable composite and used for osteosynthesis. Multiple tests were conducted on ready-to-use implants and run in simulated real-working conditions. A special customized test stand was constructed for the sake of this research. The model of the osteosynthesis consisted of two rectangular pieces of plexiglas joined together by means of the tested plate. Durability of the physical model was mechanically assessed in static uniaxial tensile, three-point bending, one-side bending tests. Two types of resorbable polymers (poly-L-lactide) and two types of composites based on these polymers were considered. The composites were modified with a combination of two types of bioceramic: micrometric tricalcium phosphate and nanometric hydroxyapatite. The relation between the geometry of the plate and its mechanical characteristics was also investigated for all the tested materials. The test results proved that incorporation of bioceramic modifiers into the polylactide matrix influences the mechanical behaviour of the tested bone plates. The composite based on FDA approved polylactide (PL38) revealed the strength decrease while the Young modulus increased at the same time. The mechanical parameters were also dependent on the geometry of the plate (localization of a stiffening rib). Better results were obtained for the plates with a stiffening rib located on the upper side of the plate. What is more, the three-point-bending test revealed that in such a case the crack line moved away from the critical cross section, making such a plate more reliable. The best parameters were achieved for the three- -component plates (PL38/TCP/Hap) with a stiffening rib on the upper side. They can be potentially applied for osteosynthesis of the bones submitted with rather low loads, e.g. craniofacial bones, metacarpal bones or phalanges. An external stiff stabilisation (a plaster cast) is recommended as an additional support and prevention.
Źródło:
Engineering of Biomaterials; 2015, 18, 133; 22-33
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wytrzymałość zmęczeniowa wielofunkcyjnej resorbowalnej płytki kompozytowej w symulowanych warunkach biologicznych
Fatigue strength tests of multifunctional resorbable composite plates in simulated biological conditions
Autorzy:
Gryń, K.
Szaraniec, B.
Chłopek, J.
Powiązania:
https://bibliotekanauki.pl/articles/286175.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
płytka zespalająca
implant wielofunkcyjny
symulowane środowisko biologiczne
wytrzymałość zmęczeniowa
czas życia
fixation plate
osteosynthesis
multifunctional implant
simulated biological environment
working time
fatigue strength
Opis:
Artykuł jest kolejną częścią prezentującą wyniki badań mechanicznych wielofunkcyjnych resorbowalnych płytek zespalających. Testy dotyczyły wyznaczenia wytrzymałości zmęczeniowej płytek ze-spalających w warunkach symulujących rzeczywiste warunki pracy. Określenie tego parametru, zwłaszcza w elementach poddawanych obciążeniom zmiennym w czasie, jest bardzo ważne ze względu na możliwość wystąpienia w materiale zmian strukturalnych np.: umocnienia odkształceniowego czy rozwoju defektów prowadzących do zniszczenia elementu. Materiały kompozytowe o osnowie polimerowej modyfikowane cząstkami ceramicznymi są stosunkowo czułe na tego typu obciążenia. Kolejnym aspektem, który musi być uwzględniony przy opisie i charakterystyce mechanicznej przedmiotowych implantów jest środowisko, w jakim się one docelowo znajdą. Temperatura, pH oraz skład chemiczny to czynniki bezpośrednio wpływające na sposób i tempo degradacji polimeru resorbowalnego. Degradacja z kolei wpływa na charakterystyki wytrzymałościowe osłabiając materiał. W prezentowanych badaniach zastosowano modelowe zespolenie, w którym rolę odłamów kostnych pełniły specjalnie przygotowane bloczki z PMMA, do których za pomocą śrub metalowych przymocowana była testowana płytka. Tak przygotowany układ mocowano w maszynie zmęczeniowej i poddawano cyklicznemu rozciąganiu. Zastosowano dwa warianty badania: pierwsze, gdzie modelowe zespolenie obciążano „na sucho” bez obecności płynów symulujących środowisko biologiczne; i drugi, gdzie modelowe zespolenie umieszczano w zamkniętym zbiorniku, wypełnionym płynem symulującym środowisko biologiczne. Jako medium zastosowano płyn Ringera podgrzewany do temperatury ~37°C.Na podstawie otrzymanych wyników stwierdzono, że płytki badane „na sucho”, cechowały się inną charakterystyką niż płytki wystawione na oddziaływanie symulowanego środowiska biologicznego.
The article is part of a series of publications presenting the results of mechanical tests of multi-functional resorbable fixation plates. Tests were con-ducted on prototype plates in conditions simulating natural biological environment. The examinations were meant to assess the so-called “implant working time” or fatigue strength of the fixation plates. This parameter is particularly important in the case of elements subjected to time-varying loads due to the possibility of alterations to the material structure, strain strengthening or development of defects leading to the implant failure. Composite materials consisting in a polymer matrix modified with ceramic particles are quite sensitive to variable loads. Moreover, the complex geometry of the tested plates makes them more vulnerable to destruction with the critical cross-sections located at the fixing holes. Another key aspect is the biological environment where the implants will perform their functions. The temperature, pH and chemical composition are factors directly affecting the way and rate of degradation of the resorbable polymer. Degradation affects the strength characteristics, obviously weakening the material. The tests were performed on a model composed of PMMA blocks playing the role of bones with the tested plate attached with metal screws. The model was mounted in a fatigue machine and subjected to cyclic stretching. Two variants of the examinations were performed. Firstly, the model was tested in “dry” conditions; secondly - in a closed container filled with fluids simulating the biological environment (the Ringer’s solution heated to ~37°C used as the medium). The results revealed that the plates tested in “dry” conditions were endowed with different characteristics as compared to the plates exposed to the simulated biological environment.
Źródło:
Engineering of Biomaterials; 2018, 21, 147; 21-30
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problems related to mechanics in the design of external osteosynthesis
Wybrane zagadnienia mechaniki w projektowaniu ortopedycznych stabilizatorów zewnętrznych
Autorzy:
Jasińska-Choromańska, D. E.
Powiązania:
https://bibliotekanauki.pl/articles/280043.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
biomechanics
modelling
osteosynthesis
Opis:
The external osteosynthesis is one of the methods of healing bone fractures. The idea of external fixators design consists in inserting into the bone fragments elements, which are coupled outside the limb by an element, called the frame of the fixator, having the fracture set. The external fixation is based on the principle of "load transfer". The design of a new generation of external fixators ought to employ some methods of mechanical analysis. Selected problems related to the modelling and simulation of physical performance of the unilateral external mechatronic orthopaedic fixator-bone system are presented. The majority of works makes use of the rigid finite element method for analysing the rthopaedic devicebone system. The paper presents some problems regarding mechanics applied in the external osteosynthesis design.
Stabilizacja zewnętrzna jest jedną z metod leczenia złamanych kończyn. Konstrukcja stabilizatorów zewnętrznych składa się z ramy nośnej umieszczonej po zewnętrznej stronie złamanej kończyny oraz wkrętów kostnych zamocowanych w odłamach złamanej kończyny i zablokowanych jednocześnie w ramie nośnej. Ideą konstrukcji stabilizatorów zewnętrznych jest "przenoszenie obciążenia" podczas procesu zrostu złamanych odłamów kostnych przez ramę nośną, a tym samym odciążenie szczeliny zrostu kostnego. W projektowaniu stabilizatorów nowej generacji wykorzystywane są wybrane zagadnienia mechaniki, które umożliwiają analizę układów biomechanicznych, takich jakim w prezentowanym artykule jest system stabilizator zewnętrzny-odłam kostny. Artykuł prezentuje zastosowanie wybranych zagadnień mechaniki w projektowaniu ortopedycznych stabilizatorów zewnętrznych nowej generacji.
Źródło:
Journal of Theoretical and Applied Mechanics; 2010, 48, 2; 453-463
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the results of mandibular fractures sugrical titanium miniplates treatment on the basis of computer-aided analysis of pantomographical radiograms
Autorzy:
Jędrusik-Pawłowska, M.
Drugacz, J.
Lamża, A.
Wróbel, Z.
Powiązania:
https://bibliotekanauki.pl/articles/333670.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
zdjęcia pantomograficzne
osteosynteza
pomiary wspomagane komputerowo
zwichnięcia kości
pantomographical radiograms
osteosynthesis
computer-aided measurement
bones dislocation
Opis:
At present, in mandibular fractures surgical treatment reposition and titanium miniplates osteosynthesis is the most common method used. The treatment results are assessed on the basis of comparative analysis of two radiograms taken before and after fixations of fractures. In this article the objective method of radiological assessment of osteosynthesis is presented. The crucial part of the method is the computer program which was created at The Institute of Computer Biomedical Systems, Silesian University in Katowice. Comparison of placement of bone fragments on a pair of pantomograms taken before and after a particular surgical operation was done. To make the process of the results evaluation an objective one a new parameter - the relative dislocation coefficient - was implemented. Achieved results enable to assess correctness of bone fracture reposition on the pantomographical pictures taken twice, once before and the next time after osteosynthesis.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT83-89
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowa metoda osteosyntezy złamań wyrostków kłykciowych żuchwy przy użyciu implantów ze stopów NiTi
NiTi shape memory staples as a novel surgical fixation method for condylar process fractures
Autorzy:
Jędrusik-Pawłowska, M.
Lekston, Z.
Kromka-Szydek, M.
Drugacz, J.
Cieślik, T.
Powiązania:
https://bibliotekanauki.pl/articles/283785.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynteza
złamania żuchwy
implanty
stopy NiTi
NiTi alloys
mandibular fractures
implants
osteosynthesis
Źródło:
Engineering of Biomaterials; 2008, 11, no. 77-80; 70-72
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Osteosynteza śródszpikowa gwoździami rozprężnymi
Osteosynthesis with the use of expansion intramedullary nails
Autorzy:
Kajzer, A.
Kajzer, W.
Marciniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/284133.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteosynteza
gwoździe śródszpikowe
implanty
osteosynthesis
intramedullary nails
implants
Źródło:
Engineering of Biomaterials; 2008, 11, no. 77-80; 74-76
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza biomechaniczna ryglowanego zespolenia śródszpikowego kości udowej
FEM analysis of locked intramedullary nails used for femur fractures treatment
Autorzy:
Kajzer, W.
Kajzer, A.
Szewczenko, J.
Marciniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/284210.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
osteozynteza
zespolenie śródszpikowe ryglowane
analiza biomechaniczna
locked intramedullary osteosynthesis
femur fractures treatment
FEM analysis
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 54-57
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wytrzymałościowa MES złamania szyjki kości udowej stabilizowanej gwoździem śródszpikowym typu GAMMA
FEM strenght analysis of tibia stabilization with ZESPOL fixator, including orthotropic properties of bone
Autorzy:
Kozub, B.
Matuszyk, Ł.
Łagan, S.
Powiązania:
https://bibliotekanauki.pl/articles/99047.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
implant
osteosynteza
modelowanie
biomechanika
MES (metoda elementów skończonych)
osteosynthesis
modelling
biomechanics
FEM
Opis:
W pracy poruszono problem stabilizacji złamania szyjki kości udowej za pomocą gwoździa śródszpikowego typu GAMMA. Dokonano oceny wpływu zastosowanego materiału stabilizatora na naprężenia, odkształcenia oraz przemieszczenia. W pracy posłużono się metodą elementów skończonych. Analizy numeryczne przeprowadzono w programie FEMAP.
Źródło:
Aktualne Problemy Biomechaniki; 2012, 6; 59-64
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computer assessment of correctness of mandiblar bones fracture slit integration based on pantomographic radiograms
Autorzy:
Lamża, A.
Wróbel, Z.
Jędrusik-Pawłowska, M.
Drugacz, J.
Powiązania:
https://bibliotekanauki.pl/articles/333660.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
zdjęcia pantomograficzne
minipłytki
osteosynteza
względny współczynnik przemieszczenia odłamów
pantomographic radiograms
miniplate
osteosynthesis
relative faction dislocation coefficient
Opis:
The method of objective assessment of the correctness mandible bones fracture slit was proposed in the research. At present, treatment results are evaluated by comparing pantomographic pictures made before and after integration. It is not an objective method; the estimation of the integration correctness coefficient is not possible, either. The use of computer processing enables introducing the relative mandible faction dislocation coefficient. Thanks to this, measurable determination of bone faction reposition correctness on pantomograms made after osteosynthesis is possible.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT119-124
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania powierzchni klamer NiTi użytych w zespoleniach złamań jarzmowo-szczękowo-oczodołowych
Surface studies of NiTi staples used in zygomatico-maxillo-orbital osteosynthesis
Autorzy:
Lekston, Z.
Łosiewicz, B.
Winiarski, A.
Jędrusik-Pawłowska, M.
Kromka-Szydek, M.
Miernik, K.
Powiązania:
https://bibliotekanauki.pl/articles/283947.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
klamry NiTi
zespolenia kości twarzoczaszki
implanty
NiTi staples
osteosynthesis
implants
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 29-33
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques
Autorzy:
Marvan, J.
Horak, Z.
Vilimek, M.
Horny, L.
Kachlik, D.
Baca, W.
Powiązania:
https://bibliotekanauki.pl/articles/306556.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza FEM
osteosynteza
złamanie kości
fibular fracture
finite element analysis
osteosynthesis
fracture fixation
fibula
Opis:
Ankle fractures are complex injuries with variable prognoses that depend upon many factors. The aim of the treatment is to restore the ankle joint biomechanical stability with maximum range of motion. Most ankle fractures are fibular fractures, which have a typical oblique fracture line in the distal fibula located in the area of the tibiofibular syndesmosis. The aim of this study was to simulate numerically several fixation techniques of the distal fibular fractures, evaluate their stability, determine their impact on surrounding tissue load, and correlate the results to clinical treatment experience. The following three models of fibular fracture fixation were used: (a) plate fixation with three screws attached above/below and lag screws, (b) plate fixation with two screws attached above/below and lag screws, and (c) three lag screws only. All three fracture fixation models were analyzed according to their use in both healthy physiological bone and osteoporotic bone tissue. Based on the results of Finite Element Analysis for these simulations, we found that the most appropriate fixation method for Weber-B1 fibular fractures was an unlocked plate fixation using six screws and lag screws, both in patients with physiological and osteoporotic bone tissue. Conversely, the least appropriate fixation method was an unlocked plate fixation with four screws and lag screws. Although this fixation method reduces the stress on patients during surgery, it greatly increased loading on the bone and, thus, the risk of fixation failure. The final fixation model with three lag screws only was found to be appropriate only for very limited indications.
Źródło:
Acta of Bioengineering and Biomechanics; 2017, 19, 1; 33-39
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie stanu odkształcenia żuchwy w przypadku zespolenia złamania kąta
Examination the state of strain mandible in case fixation of angle fracture
Autorzy:
Mosór, K.
Kromka-Szydek, M.
Powiązania:
https://bibliotekanauki.pl/articles/98775.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
żuchwa
tensometria
osteosynteza minipłytkowa
mandible
tensometry
miniplate osteosynthesis
Opis:
Praca dotyczy analizy stanu odkształcenia żuchwy w przypadku zespolenia złamania kąta z wykorzystaniem pojedynczych minipłytek, tzw. techniką Champy’ego. Zastosowano model żuchwy wykonany z żywicy epoksydowej z naklejonymi czujnikami tensometrycznymi. W badaniach eksperymentalnych wyznaczono wartości odkształcenia głównego oraz zmianę kierunku naprężenia głównego dla przypadków żuchwy zdrowej oraz po osteosyntezie płytkowej. Zasymulowano złamanie proste poprzez przecięcie modelu żuchwy na wysokości drugiego zęba trzonowego z prawej strony (ząb 37). Do badania wykorzystano 4 różne typy płytek.
The thesis consists of an analysis of the state of strain of the mandible for the angle osteosynthesis using a single miniplate by Champy technique were done. Examination performed the state of strain on the mandible model made of epoxy resin using the method with strain gauges. In the experimental research was performed the intersection of the model along the lines corresponding to the typical fractures of this mandibular area, ie, placed on the occlusal surface of the right second molar (tooth 37) - simulation of a simple fracture. There were four different miniplates, which were used in clinical practice.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 121-126
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
History of osteosynthesis in the Department of Orthopaedics and Traumatology, Medical University of Gdansk, based on examination of surgical instruments withdrawn from the operating theatre
Historia osteosyntezy w Katedrze i Klinice Ortopedii i Traumatologii Narządu Ruchu Gdańskiego Uniwersytetu Medycznego na podstawie badania narzędzi chirurgicznych wycofanych z bloku operacyjnego
Autorzy:
Osowski, Jakub
Mazurek, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2191599.pdf
Data publikacji:
2022-09-30
Wydawca:
Wydawnictwo Exemplum
Tematy:
history of medicine in Gdansk (Poland)
surgical instruments
osteosynthesis
historia medycyny w Gdańsku (Polska)
narzędzia chirurgiczne
osteosynteza
Opis:
Based on the analysis of surgical instruments withdrawn from the operating theatre, it was decided to briefly present the history of osteosynthesis in the orthopaedic department in Gdansk, Poland. Boxes with orthopaedic instruments withdrawn from the operating theatre were obtained. The instruments were grouped, numbered, photographed and catalogued. Not all obtained instruments were used in orthopaedics; the boxes contained several instruments typically used in other fields of surgery. Attempts have been made to divide orthopaedic instruments into several groups, depending on their use in bone fixation. Some specific instruments are used only in one method. The most interesting tools are discussed in detail, with attention to their features and role in shaping modern orthopaedics. Some of the obtained equipment could have been made in the Orthopaedic Workshop in the hospital. They are specific exhibits related to the development of orthopaedics in this hospital that required preservation.
Na podstawie analizy narzędzi chirurgicznych wycofanych z sali operacyjnej postanowiono pokrótce przedstawić historię osteosyntezy na oddziale ortopedycznym w Gdańsku. W badaniu wykorzystano pudła z narzędziami ortopedycznymi wycofanymi z sali operacyjnej. Narzędzia zostały pogrupowane, ponumerowane, sfotografowane i skatalogowane. Nie wszystkie narzędzia były wykorzystywane w ortopedii; pudła zawierały również kilka narzędzi typowo stosowanych w innych dziedzinach chirurgii. Podjęto próby podzielenia narzędzi ortopedycznych na kilka grup, w zależności od ich zastosowania w zespalaniu kości. Istnieje kilka specyficznych narzędzi, które są używane tylko w jednej metodzie. Szczegółowo omówiono najciekawsze narzędzia, zwracając uwagę na ich cechy i rolę, jaką odegrały w kształtowaniu współczesnej ortopedii. Część uzyskanego sprzętu mogła zostać wykonana w Pracowni Ortopedycznej w szpitalu. Są to specyficzne eksponaty związane z rozwojem ortopedii w tym szpitalu, które wymagały konserwacji.
Źródło:
Chirurgia Narządów Ruchu i Ortopedia Polska; 2022, 87, 3; 118-122
0009-479X
2956-4719
Pojawia się w:
Chirurgia Narządów Ruchu i Ortopedia Polska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies