Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "model cieplny" wg kryterium: Temat


Tytuł:
Model matematyczny do badań cieplnych dwubiegowych silników górniczych
Mathematical model for thermal investigations of two-speed mine motors
Autorzy:
Krok, R.
Wróblewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/1375015.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
model cieplny
silniki dwubiegowe
silniki indukcyjne
Opis:
The paper presents a thermal model of two-speed induction motors with water-cooled frames. This model is made basing on the method of finite differences with the use of interpretation of the heat conduction equations in the form of thermal-electrical networks. It enables calculating temperature distributions in all constructional elements of induction motor and in the stream of water flowing in the frame as well as in the streams of air flowing in ventilation ducts of the rotor core and the frame. Basing on the model, a computer program that can be used for computer aided design is developed. Exemplary thermal calculations are carried out for the two-speed induction motor of 85/250 kW. The results obtained from simulations are compared with those from thermal measurements.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 72; 179-184
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model cieplny ogniw PV i kolektorów
Thermal model PV cells and collectors
Autorzy:
Ratajczak, J.
Domke, K.
Powiązania:
https://bibliotekanauki.pl/articles/377809.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
kolektor
ogniwo PV
ogniwo fotowoltaiczne
model cieplny
Opis:
Parametry wyjściowe kolektorów oraz ogniw PV zależą od wielu czynników np. od poziomu natężenia napromienienia, widma promieniowania oraz od temperatury. Warunki pracy dowolnego ogniwa słonecznego ulegają zmianie wraz ze zmieniającym się charakterem padającego na nie promieniowania słonecznego. Producenci przekazują użytkownikowi własności ogniw fotowoltaicznych jako charakterystyki fabryczne, mierzone w znormalizowanych standardowych warunkach. Takie uśrednione warunki odbiegają znacznie od warunków rzeczywistych w jakich pracują układy fotowoltaiczne. Nie pozwalają one odpowiedzieć na pytanie jak zachowują się badane ogniwa w warunkach rzeczywistych. Są jednak dobrą podstawą do porównywania jakości ogniw fotowoltaicznych różnych producentów. Ważnym aspektem jest również wpływ temperatury powierzchni absorpcyjnej na sprawność ogniw różnego typu. W artykule zostaną omówione modele cieplne ogniw PV i kolektorów.
Output parameters tested collectors and PV panels depends on several factors such as the level of irradiance, the spectrum of radiation and temperature. Any solar cell has a different operating conditions with the changing nature of the incident solar radiation on them. Manufacturers provide the user ownership of the characteristics of the photovoltaic module factory, measured in a standardized under standard conditions. These averaged conditions deviate significantly from actual conditions in which they operate photovoltaic systems. They do not allow to answer the question how to behave panels tested in real conditions. But there are a good basis for comparing the quality of PV modules from different manufacturers. An important aspect is the effect of temperature of absorption surface of the cell efficiency of various types. This paper will discuss the thermal models of solar PV cells and collectors.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 70; 291-298
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odtwarzanie rozkładu średnich temperatur wybranych elementów silników indukcyjnych przy wykorzystaniu metody zastępczych schematów cieplnych
Reproduction course of average temperature in selected elements of induction motors, for used thermal equivalent diagram method
Autorzy:
Mnich, T.
Powiązania:
https://bibliotekanauki.pl/articles/2076390.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
rozkład temperatury
schemat cieplny
schemat zastępczy
model cieplny
Opis:
The paper presents the thermal equivalent diagram method for define of stator and squirrel cage windings resistance thermal increases of the induction motor. In article discussed assumption form construction thermal equivalent diagram. Them monitoring of heating of induction motor is presented for example two motors, on power 3 [kW] and 18,5 [kW]. Presents verification measurements increase temperatures in 3 kW induction motor on measurements station and 18,5 [kW] on base date received from producer of induction motor. In next part of paper was reduction structure of thermal equivalent diagram. Reduction depended to change structure of diagram (e.g. to omit flow of heat between some part of motor) and power loss (e.g. bearing friction and cooling loses). For diagrams, who was construct in effect simplification assumption, effect of computer simulation is presented. Precision of computer simulations was compare with basing thermal equivalent diagram - verifying in laboratory measurements. Courses of stator and rotor windings temperature and rear bearing are presented. In the end of paper author presents conclusion from computer simulation and laboratory measurements, who was application this method in practical application.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 77; 237-242
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład temperatury w pręcie uzwojenia stojana turbogeneratora
Temperature distribution of turbogenerator stator winding bar
Autorzy:
Gurazdowski, D.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/2076350.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
model cieplny
turbogenerator
uzwojenie stojana
stojan
rozkład temperatury
Opis:
This paper present the mathematical model of thermal spread within stator winding bar in active part as well as the result of the calculation carried out by using this model. This model was created to take advantage of the heat diagram method. It was necessary to split winding bar into parts, inside which temperature is constant. In this way the substitute heat diagram has been obtained according to rules of electrical diagram. The results presented by this paper are applied to two cases of phase distribution inside the calculated slot. First case, the top and bottom bar has the same phase inside slot (slot number 1), for which temperature distribution is computed. Second case, bars belong to different phase (slot number 9). The computations were made for selected type of turbogenerator with indirectly cooled system and radial ventilation ducts. On the basis of running test result of this machine, the thermal model verification was carried out. The calculated temperature of spacer was checked with measurements.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2006, 75; 177-183
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cieplne badania symulacyjne stosowane przy opracowywaniu projektów modernizacji generatorów synchronicznych
Thermal simulation investigations applied when working out modernisation projects of synchronous generators
Autorzy:
Krok, R.
Sieradzki, S.
Adamek, J.
Powiązania:
https://bibliotekanauki.pl/articles/1374770.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
modernizacja generatorów
generator synchroniczny
model cieplny
badania symulacyjne
Opis:
The paper presents a software package for thermal computations of synchronous generators. The programs included in this package are applied when working out modernisation projects of synchronous generators for ,,ENERGOSERWIS" S.A. They enable carrying out thermal computations of the main construction elements of generators. They were used for working out quite a few modernisation projects of synchronous generators of 30 MW up to 500 MW aiming at increase in the rated power, replacement of the cooling medium (e.g. hydrogen by air), increase in the life and improvement of the weakest construction nodes. The use of the developed computer programs is illustrated by the example of a TGH-120 generator modernisation aiming at increase in its rated power up to 130 MW. Also the implementation of the TGH-120 generator modernisation to the manufacturing process in ,,ENERGOSERWIS" S.A. is presented in the paper. The measurement results are compared with the computation results.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2006, 74; 115-120
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ chłodzenia i obliczenia cieplne maszyny z magnesami trwałymi i zewnętrznym wirnikiem
Cooling system and thermal calculation of the permanent magnet machine with external rotor
Autorzy:
Szczypior, J.
Jakubowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1812169.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
model cieplny
maszyna z magnesami trwałymi
napęd bezpośredni
Opis:
In this paper, the construction of permanent magnet machine with external rotor was presented. The liquid coolant cooling of the machine was discussed. Distribution of the temperature in cross section of the machine obtained from the solution of thermal network in steady state, was presented. The influence of parameters the cooling medium on temperature distribution in different parts of the machine was studied. The dependence of the maximum temperature of the stator windings on the degree of overloading the machine and the coolant flow rate was calculated. Maximum continuous overload the machine, at which the winding temperature does not exceed the accepted maximum value was specified.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2012, 66, 32; 408-417
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy układu chłodząco-grzewczego z ogniwem Peltiera
Analysis of operation of cooling-heating systems with Peltier module
Autorzy:
Łyskawiński, W.
Szeląg, W.
Grześkowiak, D.
Powiązania:
https://bibliotekanauki.pl/articles/377419.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
moduł Peltiera
układ chłodząco-grzewczy
model cieplny
analiza
badania
Opis:
W artykule przedstawiono opracowany układ chłodząco-grzewczy z ogniwem Peltiera, w których strona gorąca ogniwa była chłodzona na dwa sposoby: przy pomocy bloku wodnego i przy wykorzystaniu radiatora z wentylatorem. Opracowano modele cieplne układu i wdrożono do obliczeń oprogramowanie do wyznaczania parametrów modułów Peltiera oraz wartości temperatur w wybranych punktach układu. Porównano otrzymane wyniki obliczeń z rezultatami badań eksperymentalnych uzyskanych na zbudowanym stanowisku pomiarowym. Na tej podstawie sformułowano wnioski i przedstawiono propozycje rozwiązań poprawiających właściwości funkcjonalne badanego układu.
The paper presents a developed cooling and heating system with a Peltier module. The heat side of the Peltier module was cooled in two ways: by means of a water block and by using a radiator with a fan. Algorithm and software for analysis of the cooling-heating system with the Peltier module were developed. The software were used to calculate parameters of the Peltier module, efficiency and temperature values at selected points of the system. The obtained results of calculations were compared with the results of experimental tests obtained on the built measuring stand. On this basis, the conclusions were formulated and the proposals for solutions improving the functional properties of the tested system were presented.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 231-242
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rozłożenia przewodów w żłobku stojana na nagrzewanie silnika indukcyjnego
Influence distribution wires in the stator slot of winding heat the induction machine
Autorzy:
Milej, W.
Powiązania:
https://bibliotekanauki.pl/articles/1374148.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
maszyna indukcyjna
model cieplny
rozkład temperatury
rezystancja uzwojenia
Opis:
Results of field calculations for a two-dimensional thermal model of induction machine was presented in this paper. Calculations and measurements have been provided for an induction squirrel-cage motor of low power and the following ratings: P(N)=1.5 kW, 2p=4, f(N)=50 Hz, U(N)=3x380 V. A two-dimensional geometric model has been proposed for field calculations and the model has been divided into areas with different physical properties of materials and structure. Within these areas thermal equations (1) have been defined; they use different parameters and were solved with partial differential equations. Two simulation models (Fig. 1.) reduced which consists of a single stator slot and a single rotor slot were discussed in this paper. During simulations, a solution of the thermal model has represented a distribution of temperature increase in the induction machine (Fig. 4 and Fig. 5.) and resistivity functions (Fig. 6). This work has been sponsored in 2008 as AGH University Grant no. 11.11.120.615.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2008, 80; 95-98
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic Rating of 110 kV Overhead Lines
Wyznaczanie dynamicznej obciążalności linii napowietrznych 110 kV
Autorzy:
Babś, A.
Samotyjak, T.
Powiązania:
https://bibliotekanauki.pl/articles/396824.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
dynamic line rating
thermal line model
load forecasting
dynamiczna obciążalność linii
model cieplny linii
prognozowanie obciążenia
Opis:
The paper justifies the need of using, within the 110 kV networks, a dynamic line rating model along the power lines. The work describes in detail the way in which the dynamic line rating is determined, basing the process solely on measurement of the weather conditions. Some aspects related to selection of the numerical values of the coefficients present in the heat model of the power-lines, which is being used to determine the dynamic line rating and the distance between the ground and the conductor, have been described. Subsequent stages of implementation of the system used to determine the dynamic line rating of the power lines have also been described. These include selection of the critical spans of the overhead lines, in case of which risk of exceeding the distance to the crossed-over objects is higher than in case the of the other spans of the very same power line. Additionally, optimal displacement of the weather-reporting stations, that are the source of the data used to determine the dynamic line rating of the lines, has been described. The work also deals with applications of the dynamic line rating for the power line related to the dangerous situation in case of which rime (ice) would be accumulated on the conductors. The forecasting procedures, regarding the load imposed on the power-lines, within a defined time period are also considered by the present paper. Forecasting the permissible load for the power lines is one of the main elements of planning an energy transmission system. Conclusions have been drawn regarding selection of the methodology which is to be used to determine the dynamic line rating, and the way of implementing and using these conclusions within the scope of maintaining the electric energy network.
W artykule uzasadniono celowość i potrzebę wykorzystywania w prowadzeniu ruchu sieci 110 kV dynamicznej obciążalności linii. Szczegółowo opisano wyznaczanie dynamicznej obciążalności linii z wykorzystaniem wyłącznie pomiaru warunków pogodowych. Opisano niektóre aspekty doboru wartości liczbowych współczynników występujących w modelu cieplnym linii, wykorzystywanym do wyznaczania dynamicznej obciążalności linii oraz odległości przewodu od ziemi. Opisano kolejne etapy wdrożenia systemu wyznaczania dynamicznej obciążalności linii, związane m.in. z wyborem przęseł krytycznych, tj. przęseł, w których ryzyko przekroczenia minimalnej odległości od obiektów krzyżowanych jest większe niż w przypadku innych przęseł tej samej linii, oraz optymalnym rozmieszczeniem stacji pogodowych będących źródłem danych dla wyznaczania dynamicznej obciążalności linii. Opisano również inne zastosowania wyznaczania dynamicznej obciążalności linii związane z monitorowaniem jej zagrożenia wystąpieniem oblodzenia (szadzi) oraz prognozowania obciążenia linii w określonym horyzoncie czasowym. Prognozowanie dopuszczalnego obciążania linii jest jednym z elementów planowania pracy systemu elektroenergetycznego. Sformułowano wnioski co do wyboru metody wyznaczania dynamicznej obciążalności linii oraz sposobu wdrożenia i wykorzystania w prowadzeniu ruchu sieci elektroenergetycznej.
Źródło:
Acta Energetica; 2016, 3; 4-9
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study on thermal comfort at university buildings in Slovakia
Eksperymentalne badanie komfortu cieplnego w budynkach uniwersyteckich na Słowacji
Autorzy:
Orman, Łukasz J.
Kapjor, Andrej
Powiązania:
https://bibliotekanauki.pl/articles/2203969.pdf
Data publikacji:
2023
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
thermal sensations
Fanger model
komfort cieplny
wrażenia cieplne
model Fangera
Opis:
The paper discusses the issue of thermal comfort expressed by the students of the University of Žilina in anonymous questionnaires. The volunteers rated their thermal sensations, preferences as well as lighting conditions in the autumn season. The students were in favour of the prevailing thermal conditions - almost 88% of the volunteers expressed positive opinions about their environment. The comparison of the test results for a computer laboratory with the Fanger model calculation results was also made and indicated differences between the experimental data and values determined with the model.
W artykule omówiono zagadnienie komfortu cieplnego studentów Uniwersytetu w Żylinie w oparciu o anonimowe ankiety. Ochotnicy oceniali swoje odczucia termiczne, preferencje oraz warunki oświetleniowe w okresie jesiennym. Studenci wyrazili się pozytywnie w zakresie panujących warunków termicznych - blisko 88% odpowiedzi. W pracy dokonano również porównania wyników badań w laboratorium komputerowym z wynikami obliczeń wg modelu Fangera i wykazano różnice między danymi eksperymentalnymi a wartościami wyznaczonymi modelem.
Źródło:
Structure and Environment; 2023, 15, 1; 1--5
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Process engineering in iron production
Autorzy:
Pustejovska, P.
Jursova, S.
Powiązania:
https://bibliotekanauki.pl/articles/184940.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat balance
kinetic model
carbon consumption
reducibility
bilans cieplny
model kinetyczny
zużycie węgla
redukowalność
Opis:
Balance, thermodynamic and mainly kinetic approaches using methods of process engineering enable to determine conditions under which iron technology can actually work in limiting technological states, at the lowest reachable fuel consumption (reducing factor) and the highest reachable productivity accordingly. Kinetic simulation can be also used for variant prognostic calculations. The paper deals with thermodynamics and kinetics of iron making process. It presents a kinetic model of iron oxide reduction in a low temperature area. In the experimental part it deals with testing of iron ore feedstock properties. The theoretical and practical limits determined by heat conditions, feedstock reducibility and kinetics of processes are calculated.
Źródło:
Chemical and Process Engineering; 2013, 34, 1; 63-76
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do badań łożysk ślizgowych z wykorzystaniem bilansu cieplnego
Laboratory stand for tests of slide bearings based on heat balance
Autorzy:
Lepiarczyk, D.
Gawędzki, W.
Tarnowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/187891.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
łożysko ślizgowe
model energetyczny
bilans cieplny
współczynnik tarcia
slide bearings
energetic model
heat balance
friction coefficient
Opis:
W pracy przedstawiono konstrukcję stanowiska laboratoryjnego do badań łożysk ślizgowych z wykorzystaniem bilansu cieplnego. Zamieszczono opis zabudowanych na stanowisku torów pomiarowych momentu tarcia oraz pomiaru temperatury. Stanowisko umożliwia realizację badań dowolnie wybranych skojarzeń materiałowych współpracujących ślizgowo. Istnieje możliwość energetycznego wyznaczania wartości współczynników tarcia na kontakcie czopa i panewki.
In the paper design of the laboratory test stand for slide bearings tests based on heat balance is presented. The description of friction torque and temperature measurement systems installed on the stand are given. The stand enables realization of any chosen material combination in sliding cooperation. There is possibility of energetic determination of friction coefficient in the bush and pivot contact.
Źródło:
Tribologia; 2012, 1; 85-91
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczne modelowanie dynamiki płaskich cieczowych kolektorów słonecznych
Numerical modelling of liquid flat-plate solar collectors dynamics
Autorzy:
Zima, W.
Dziewa, P.
Powiązania:
https://bibliotekanauki.pl/articles/172961.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kolektor słoneczny
ogniwo słoneczne
model matematyczny
proces cieplny
solar collector
solar cell
mathematical model
thermal process
Opis:
W pracy przedstawiono jednowymiarowy modei matematyczny pozwalający na symulowanie nieustalonych procesów cieplnych zachodzących w rurkach płaskich cieczowych kolektorów słonecznych. Jest to model o parametrach rozłożonych, w którym analizie przepływowo-cieplnej poddawana jest tylko jedna rurka kolektora, a warunki brzegowe mogą być zależne od czasu. Proponowany model oparty jest na rozwiązaniu równania bilansu energii po stronie czynnika roboczego. Przebieg temperatury ścianki rurki wyznaczany jest natomiast z rozwiązania równania nieustalonego przewodzenia ciepła. Wyprowadzone równania różniczkowe rozwiązano iteracyjnie z wykorzystaniem niejawnego schematu różnicowego. Wszystkie własności termofizyczne czynnika oraz materiału ścianki rurki (absorbera) mogą być obliczane na bieżąco. W celu przedstawienia dokładności i efektywności prezentowanej metody, przeprowadzono weryfikację obliczeniową oraz eksperymentalną. Weryfikacja obliczeniowa polegała na porównaniu wyników uzyskanych za pomocą proponowanej metody z wynikami dostępnych rozwiązań ścisłych dla stanów nieustalonych. Uzyskano w pełni zadowalającą zgodność tych wyników. W celu przeprowadzenia weryfikacji eksperymentalnej zbudowano stanowisko badawcze oraz uzupełniono model matematyczny kolektora o dodatkowe równania bilansowe. Równania te zapisano i rozwiązano dla szyby solarnej, izolacji oraz dla warstwy powietrza pomiędzy szybą i absorberem. Porównując wyniki pomiarów nieustalonej temperatury czynnika na wylocie z kolektora z wynikami obliczeń numerycznych, stwierdzono zadowalającą ich zgodność.
The paper presents a one-dimensional mathematical model for simulating the transient processes which occur in the liquid flat-plate solar collector tubes. The proposed method considers the collector model as the one with distributed parameters. In the suggested method one tube of the collector is taken into consideration. In this model the boundary conditions can be timedependent. The proposed model is based on solving equation describing the energy conservation at the operating fluid side. Temperature of the tube wall is determined from the equation of transient heat conduction. The derived differential equations were solved using the implicit finite difference method of iterative character. All thermophysical properties of the fluid and the material of the tube wall can be computed in real time. As an illustration of accuracy and effectiveness of the suggested method the computational and experimental verifications were performed. The computational verification consists in comparing the results found using the presented method with results of available analytic solutions for transient operating conditions. A satisfactory convergence of these results was achieved. In order to experimentally verify the proposed method a research stand was built and the suggested mathematical model was extended by the additional equations. These equations were derived for glass cover, insulation, and for air gap between cover and absorber satisfactory convergence is found comparing the measurement results of the transient fluid temperature at the collector outlet with computational results.
Źródło:
Archiwum Energetyki; 2011, 41, 2; 59-73
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Opór przejmowania ciepła na wewnętrznej powierzchni obudowy w obszarze trójwymiarowych mostków cieplnych według PN-EN ISO 10211-1
Thermal resistance on the internal surface of envelope in area of three-dimensional thermal bridges according to PN-EN ISO 10211-1
Autorzy:
Geryło, R.
Powiązania:
https://bibliotekanauki.pl/articles/183169.pdf
Data publikacji:
2005
Wydawca:
Instytut Techniki Budowlanej
Tematy:
opór przejmowania ciepła
mostek cieplny
mostek trójwymiarowy
przegroda zewnętrzna
pole temperatury
model obliczeniowy
Opis:
Przedstawiono wyniki obliczeń wartości oporu przejmowania ciepła na wewnętrznej powierzchni przegród w obszarze węzłów konstrukcyjnych według PN-EN ISO 10211-1. Obliczenia przeprowadzono w ramach prac nad przygotowaniem założeń modelowych warunków przejmowania ciepła w obszarach trójwymiarowych mostków cieplnych, czyli miejscach szczególnego manifestowania ich wpływu na temperaturę powierzchni wewnętrznej przegród. Właściwe określenie warunków przejmowania ciepła jest konieczne do prowadzenia diagnostyki cieplnej przegród zewnętrznych przy wykorzystaniu analizy numerycznej pola temperatury.
The paper shows results of calculations of thermal resistance on internal surface of building envelope in area of construction joints according to PN-EN ISO 10211-1. Calculations were carried out in the framework of works on preparation of assumptions for modeling surface heat transfer conditions in area of three-dimensional thermal bridges, where heat transfer conditions have particular influence on internal surface temperature of building envelope. Proper determination of surface heat transfer conditions is necessary to carry out thermal diagnostics of building envelope using numerical analysis of temperature field.
Źródło:
Prace Instytutu Techniki Budowlanej; 2005, R. 34, nr 3, 3; 31-43
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Mechanical Interactions Between the Casting and the Mold on the Conditions of Heat Dissipation: A Numerical Model
Wpływ oddziaływań mechanicznych między odlewem a formą odlewniczą na warunki oddawania ciepła: model numeryczny
Autorzy:
Dyja, R.
Gawrońska, E.
Sczygiol, N.
Powiązania:
https://bibliotekanauki.pl/articles/354252.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shrinkage gap
solidification process
heat dissipation
thermo-elastic-plastic model
thermal resistance
szczelina skurczowa
proces krzepnięcia
rozpraszanie ciepła
model termo-sprężysto-plastyczny
opór cieplny
Opis:
We present a description of the effects of thermal interactions, which take into account formation of a shrinkage gap, that affect the level of stresses in a system casting – mold. Calculations were carried out in our own computer program which is an implementation of the finite element method used to solve the equations describing a thermo-elastic-plastic model of material and the heat conduction, including solidification. In the computing algorithm we use our own criteria for mechanical interaction between the casting and mold domains. Our model of mechanical interactions between the casting and the mold allows efficient modeling of stresses occurring in the casting and an impact of development of the shrinkage gap on cooling course.
W artykule przedstawiamy opis oddziaływań cieplnych, uwzględniający tworzącą się szczelinę skurczową, które wpływają na poziom naprężeń w układzie odlew – forma odlewnicza. Obliczenia przeprowadzono we własnym programie komputerowym będącym implementacją metody elementów skończonych użytej do rozwiązania równań opisujących termosprężysto–plastyczny model materiału oraz przewodzenia ciepła z uwzględnieniem krzepnięcia. W algorytmie obliczeniowym wykorzystujemy własne kryteria wzajemnego oddziaływania mechanicznego obszarów odlewu i formy odlewniczej. Opracowany model oddziaływań mechanicznych między odlewem a formą odlewniczą pozwala na efektywne modelowanie naprężeń powstających w odlewie oraz wpływ rozwoju szczeliny skurczowej na przebieg stygnięcia.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1901-1907
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies